Engineering Reliability — IEG 302 | Assignment No. 5
College of Engineering & Architecture
Al Yamamah University
Engineering Reliability — IEG 302
Assignment No. 5 — Solutions
Problem 1
A component experiences chance (CFR) failures with an MTTF of 1100 hr. Find:
(a) The reliability for a 200-hr mission
(b) The design life for a 0.90 reliability
(c) The median time to failure
Given Information:
1. Failure distribution: Constant Failure Rate (CFR) which is Exponential distribution
2. MTTF = 1100 hr
Governing Equations:
π
MTTF
πΉ(π) = π−ππ
π₯π§β‘(πΉ)
πdesign = −
π
π₯π§β‘(π)
πmedian =
π
π=
Step 1 — Compute the failure rate λ:
π
π=
= π. πππ × ππ−π failures/hr
ππππ
Part (a) — Reliability for a 200-hr mission
πΉ(π) = π−ππ
−π.πππ×ππ−π ×πππ
πΉ(πππ) = π
= π−π.πππππ
πΉ(πππ) = π. ππππ (83.38%)
Part (b) — Design life for R = 0.90
From πΉ(π) = π−ππ → π = −
π₯π§β‘(πΉ)
π
π=−
π₯π§β‘(π. ππ)
π. πππ × ππ−π
π=−
−π. πππππ
π. πππ × ππ−π
Page 1 of 3
Engineering Reliability — IEG 302 | Assignment No. 5
π. πππππ
π. πππ × ππ−π
πdesign = πππ. π hr
π=
Part (c) — Median time to failure
Formula:
πmedian =
π₯π§β‘(π) π. ππππ
=
π
π
Substituting:
πmedian =
π. ππππ
π. πππ × ππ−π
πmedian = πππ. π hr
Problem 2
A CFR system with λ = 0.0004 has been operating for 1000 hr. What is the probability that it will fail in
the next 100 hr? The next 1000 hr?
Given Information:
1. Failure distribution: CFR → Exponential distribution
2. λ = 0.0004 failures/hr
3. System has already operated for tβ = 1000 hr
π·(fail in next π«π) = π − π−π⋅π«π
Part (a) — Probability of failure in the next 100 hr
π· = π − π−π.ππππ×πππ = π − π−π.ππ
π· = π − π. ππππ
π·(fail | next 100 hr) = π. ππππ (3.92%)
Part (b) — Probability of failure in the next 1000 hr
π· = π − π−π.ππππ×ππππ = π − π−π.π
π· = π − π. ππππ
π·(fail | next 1000 hr) = π. ππππ (32.97%)
Problem 3
A hydraulic system is comprised of five components having the following constant failure rates (times in
days):
Component
1
2
3
4
Page 2 of 3
Engineering Reliability — IEG 302 | Assignment No. 5
λ (failures/day) 0.001 0.005 0.0007 0.0025 0.00001
(a) Find the system MTTF and standard deviation.
(b) Find the system design life if a 0.99 reliability is desired.
πsys = ππ + ππ + ππ + ππ + ππ
Calculation of System Failure Rate:
πsys = π. πππ + π. πππ + π. ππππ + π. ππππ + π. πππππ
πsys = π. πππππ failures/day
Part (a) — System MTTF and Standard Deviation
1
1
=
πsys 0.00921
MTTFsys =
MTTFsys = 108.58 days
π = MTTF =
1
πsys
π = 108.58 days
Part (b) — Design Life for R_sys = 0.99
Using the reliability function for a series CFR system
π
sys (π‘) = π −πsys ⋅π‘
Solving for π‘:
π‘=−
lnβ‘(π
sys )
πsys
lnβ‘(0.99)
0.00921
−0.01005
π‘=−
0.00921
π‘=−
π‘=
0.01005
0.00921
π‘design (π
= 0.99) = 1.091 days ≈ 26.2 hr
Page 3 of 3