PROCESS PLANT INTEGRITY & RELIABILITY
OAC 5243
Take Home Assignment 1
Submission Date: 30th June 2022
An electrical transmission line has been tested and found to have a CFR of 0.001
defects per foot.
Assuming exponential behavior, intensity parameter λ = 0.001/ft,
Find:
a. R(100)
b. R(1000)
c. MTTF, which here is mean distance to a defect
d. Standard Deviation
e. tmed
f. 90 percent design life