Groundwater
Importance of Ground Water
Much of the total water used in the country exclusive
of hydroelectric-power generation comes from
groundwater pumped each day.
Groundwater temperature remains relatively low
during the summer and is also used for air
conditioning and industrial cooling.
Aside
from its great economic importance,
groundwater is also an important phase of the
hydrologic cycle.
Continued…
Introduction
Groundwater is that portion of the water, beneath
the surface of the earth that can be collected from
wells, tunnels, or drainage galleries, or which flows
naturally to the earth’s surface via seeps or springs.
This water is due to infiltrated part of the rainfall. The
water may have infiltrated directly into the ground
where it landed, or it may first have collected in
streams and lakes and then seeped into the ground.
The water moves downwards under the influence of
gravity until it reaches the impervious strata. It then
begins to move in a lateral direction towards some
outlet.
Continued…
Importance of Ground Water
Because groundwater is relatively free of pollution it is
especially useful for domestic purposes, particularly
for isolated farms and small towns in the arid regions.
In such places groundwater is often the only source of
water for irrigation. There are about 400,000 tubewells in Pakistan which pump about 66 billion cubic
meters of groundwater annually.
In villages almost every household has a hand-pump
to pump groundwater for domestic use.
Continued…
Importance of Ground Water
Most perennial streams derive the greater part of their
flow from groundwater, while in arid regions, much of
the surface stream flow percolates to the groundwater.
The occurrence and movement of sub-surface water
are necessarily related to geological structures, and
knowledge of Geology is a pre-requisite to a thorough
comprehension of groundwater hydrology.
For the countries like United States, it is
estimated that about 25 percent of the
precipitation becomes groundwater.
Continued…
Aquifers
Groundwater
bearing formations sufficiently
permeable to transmit and yield water in sizeable
quantities are called aquifers.
These are of two types:
Confined or Artesian Aquifer
Unconfined Aquifer
Continued…
Confined or Artesian Aquifer
It is a soil formation which can store and can transmit
water under pressure. There is no atmospheric pressure on
the top surface of groundwater.
It is found between two impervious strata as shown in
Fig1. Confined aquifers are filled with ground water, and
they do not have a free water table.
The pressure condition in a confined aquifer is
characterized by the piezometric surface, which is the
surface obtained by connecting equilibrium water levels in
tubes/wells or piezometers, penetrating the confined
aquifer as shown in Fig. 1 below.
Continued…
Confined or Artesian Aquifer
Natural Ground Surface
Water Filled Strata
Figure 1
Continued…
Unconfined Aquifer
It is soil formation which can store water and
can transmit it in vertical as well as in lateral
direction.
It is defined as that water bearing strata in
which there is a free surface of groundwater at
the top having atmospheric pressure.
This top surface having atmospheric pressure
is called the water table. Refer Fig. 2 below.
Continued…
Unconfined Aquifer (figure 2)
Natural Ground Level
Water Bearing Strata
Continued…
Soil Formations
Aquiclude
An aquiclude is a soil formation which can store water but
cannot transmit it. Its permeability is negligibly small.
Aquitard
A soil formation which is permeable in vertical direction
and is impermeable in lateral direction is called an aquitard.
Aquifuge
Soil
formation which can neither store water nor can
transmit it is called an aquifuge. Its permeability is nearly
zero.
Continued…
Storage Coefficient and Specific Yield
The storage coefficient of an aquifer is defined
as the volume of water yielded per unit surface
area and per unit drop of water-table in case of
unconfined aquifers.
In case of confined aquifers, it is volume of
water yielded per unit surface area and per unit
drop of piezometric surface.
If water is allowed to drain from a saturated
sample of an aquifer, some water will drain freely
under gravity.
The Specific Yield is the ratio of the volume of
water drained divided by the volume of soil
sample.
Darcy’s Law
Darcy’s law states that the velocity flux ‘V’ is directly
proportional to hydraulic gradient.
V α dh/dl
where ‘h’ is the total hydraulic head (pressure head +
elevation head) of water
Continued…
Darcy’s Law
V=k dh/dl - - - - - - - - - - - - - - - - - - - - - - - - - - - (1)
The factor of proportionality ‘k’ is a property of the soil or rock material,
and it is called the hydraulic conductivity.
If piezometers are placed at two points on a groundwater streamline
(points 1 and 2 in figure 3 ). The velocity of the groundwater in that
stream can be calculated with the equation.
V = k[(Z1+h1)-(Z2+h2 )]/L - - - - - - - - - - - - (2)
Where,
V = Darcy velocity of water (length / time)
h1 = Pressure head at point 1 (length)
Z1 = Elevation head at point 1 (length)
h2 = Pressure head at point 2 (length)
Z2 = elevation head at point 2 (length)
L = distance along flow between points 1 and 2 as measured along
streamline (length)
Continued…
Darcy’s Law:
Fig. 3 Flow through Porous Media
Darcy’s Law
Equation (1) or modifications thereof are called
Darcy’s equation, after the French Hydrologist
Henry Darcy.
The Darcy velocity is not the real macroscopic
velocity of water, but the discharge is divided by
entire cross-sectional area normal to the flow,
(solids as well as pores) to get Darcy’s velocity.
The pressure head ‘h’ at a given point in the flow
system is the height to which water will rise in a
piezometer inserted down to that point.
The elevation head of a given point is the vertical
distance of that point above an arbitrary,
horizontal reference plane.
Continued…
Darcy’s Law
The sum of pressure head and elevation head at a
given point in the flow system is called the total
hydraulic head ‘H’. Thus ‘h1+Z1’ in equation. (2)
is the total head H1, at point ‘1’ and h2+Z2 is the
total hydraulic head H2 at point ‘2’.
The distance ‘L’ between points 1 and 2 must be
measured along the streamline on which the
points are located. The ratio ( H1-H2 )/L is called
the hydraulic gradient of the flow.
Validity of Darcy’s Law: (Limitations)
Darcy’s Law (Darcy’s equation) is valid only for
steady laminar flow. With this type of flow,
velocities are relatively small & water molecules
travel in smooth paths, more or less parallel to
the solid boundaries of the pores (in capillary
tubes with uniform diameters, water molecules,
move exactly parallel to the tube walls).
Laminar flow is governed by the viscous forces
of the fluid, so that head losses vary linearly with
velocities, as in Darcy’s equation.
Continued…
Validity of Darcy’s Law:
If
the velocities increase, a point is reached
whereby the inertial forces increase significantly
and particles travel in irregular paths, forming
eddies, swirls and other turbulences as can be
observed in rapidly flowing streams.
In this type of flow, which is called turbulent
flow, head losses vary exponentially with the
velocities of the fluid and not as per Darcy’s
Law.
Continued…
Validity of Darcy’s Law:
Groundwater
movement occurs almost always
as laminar flow. Turbulent flow may develop
where the pores and the hydraulic gradient are
both large.
This could happen in the immediate vicinity of
pumped walls or in very porous formations,
particularly near springs or seeps where the flow
is concentrated.
Continued…
Well Hydraulics for Steady State Pumping
Confined Aquifers
The flow system around a pumped or flowing well in a
confined aquifer can be analyzed with the Dupuit
Forchheimer assumption of horizontal flow.
At steady state, the flow in the aquifer comes from far
away, so that the flow across an imaginary cylindrical
surface in the aquifer at radius “r”, from the pumped well is
the same as the flow ‘Q’ from the well.
The well has its influence to a certain radial distance after
which the water levels remain unchanged. This radial
distance is called radius of influence.
Continued…
Well Hydraulics for Steady State Pumping
In general the flow can be expressed as
Q = AV - - - - - - - - - - - - - - - - - (3)
‘A’ is the cross-sectional area and ‘V’ is the Darcy’s
velocity.
From Darcy’s Law, we have, V = K x dh/dl with usual
notations and in case of pumped well at steady state the
flow is radial, so V= K x dh/dr, where ‘h’ is the
hydraulic head and ‘r’ is the radius. ‘d’ represents small
value as delta.
Continued…
Well Hydraulics for Steady State Pumping
Cone of depression due to steady state pumping in a
confined aquifer is shown in figure 4.
In this figure ‘s’ represents the drawdown at radial
distance r, which is drop of piezometric level due to
pumping from its original level before pumping.
The area of cylindrical surface at radial distance ‘r’ from
the center of well.
A=2 rD
Continued…
Well Hydraulics for Steady State Pumping
Fig. 4: Cone of depression for steady state pumping in a confined aquifer
Continued…
Well Hydraulics for Steady State Pumping
Now the flow can be represented as:
Q = 2rD.Kdh/dr
Where,
(see figure 4)
Q = flow from well (volume/time)
k = hydraulic conductivity of aquifer
r = radial distance from well centre
D = thickness of aquifer
dh/dr = hydraulic gradient (slope of piezometric head
‘h’ at distance ‘r’ from pumped well).
Continued…
Well Hydraulics for Steady State Pumping
The piezometric head “h” is expressed with respect to the bottom
of aquifer.
Rearranging above equation
Q dr/r = 2KD dh
Integration both sides from radial distance r1 where the hydraulic
head is h1 to r2 where the hydraulic head is h2.
Q (ln(r2/r1)) = 2KD(h2 – h1)
Q = 2KD{(h2–h1)}/{ln(r2/r1)} - - - - - - - - (4)
This equation is known as the Thiem equation, after the father
son team of Adolph and Gunter Thiem that developed this
equation late in the nineteenth century.
Continued…
Well Hydraulics for Steady State Pumping
Unconfined Aquifer
Cone
of depression due to steady state pumping in an
unconfined aquifer is shown in figure 5.
In this figure ‘s’ represents the drawdown at radial distance
‘r’, which is drop of water table level due to pumping from
its original level before pumping.
In general, the discharge can be expressed as
Q = AV
Where ‘A’ is area of cross–section of flow and ‘V’ is the
mean velocity (Darcy Velocity here)
From Darcy’s Law,
V = K x dh/dl
and in case of pumped well where the flow is radial,
V = K x dh/dr
Continued…
Well Hydraulics for Steady State Pumping
Fig. 5:
Cone of depression for steady state pumping in a unconfined aquifer
Well Hydraulics for Steady State Pumping
Now for an unconfined aquifer, the area of cylindrical
surface under consideration (area perpendicular to
flow) is
A = 2rh (see Fig.5)
Q = [2rh].[K x dh/dr]
Q.dr/r = 2 K h.dh
Integration both sides from radial distance r1 where
the hydraulic head is h1 to r2 where the hydraulic head
is h2.
Q (ln(r2/ r1) = K ((h2)2 - ((h1)2)
Q = K [{(h2)2- ((h1)2}/{(ln(r2/r1)}] - - - - - - - (5)
Continued…
Example 1
A well with a radius of 0.5 m completely penetrates an unconfined aquifer
with k=30 m/day and water table height from an impermeable strata at
the bottom of aquifer H=50 m.
The well is pumped so that the water level in the well remains at 40 m
above the bottom of the aquifer assuming that pumping has no effect on
water table height at r=500 m.
What is steady state well discharge?
Solution
k = 30 m/day
k = 30/(24x60x60) m/sec = 0.0003472 m/sec
r1 = 0.5 m
h1= 40m.
r2 = 500 m
h2 = H = 50 m
Q = k[(h2)2-(h1) 2] / ln(r2/r1)
= 3.1415 x 0.0003472 (502 - 402) / ln (500 / 0.5)
= 0.142 m3/sec
Example 2:
A well is sunk through an unconfined aquifer and is
pumped at a constant rate. The draw-down in the
observational wells are measured and the following data is
generated.
Static water depth = 15 m
Q = 0.015 m³/s
Dia of well = 1.2 m
Draw down at 7.5 m = 1.26 m
Draw down at 15.0 m = 0.84 m
Find out:
the coefficient of permeability, k
the diameter of circle of influence, and
the drawdown in the well.
Solution
(i) h1 = 15-0.84 = 14.16 m, r1 = 7.5m
h2 = 15-1.26 = 13.74 m r2 = 15m
Q = k (h2 2 - h1 2 )/ln (r2/r1)
0.015 = k [ (14.16)2 - (13.74)2 ]/ln(15/7.5)
k = 2.8 x 10 -4 m/sec
(ii) Q = k ( H2 - h2 ) /ln (R/r)
0.015 = x 2.8 x 10 -4 (152 – 13.742 )/ ln ( R/7.5)
R = 62.71 m
Dia. of circle of influence, 2R = 125.42 m
Q = k (H2 - h2 ) /ln (R/r)
0.015 = x 2.8x10 -4 (152 - h 2 )/ln (62.71/0.60)
h = 12.07 m
hence draw down
H-h = 15-12.07 = 2.93 m
(iii)
Example 3
Observational wells were drilled in a cone of depression of
artesian (confined) well, being pumped at the rate of 0.028
m³/s. The drawdown in the observational wells at 4.57 m and
12 m were found to be 7.5 m and 3 m respectively. Calculate
‘K’ of the aquifer if the average thickness of the aquifer is 30
m.
Solution
b = 30 m
Q = 0.028 m³/s
r1 = 4.57 m
r2 = 12 m
drawdown S1 = 7.5 m
drawdown S2 = 3.0 m
k = ?
h1 = H - S1
h2 = H - S2
We have the formula,
Q = 2KD ( h2 - h1 ) / ln ( r2/r1 )
Q = 2kb (H - S2 - H + S1 )
ln (r2/r1)
0.028 = 2 x 3.1415x k x 30 (7.50-3.0)/ ln (12/4.57)
k = ln (12/4.57) x 0.028 x / (2x 3.1415x30 x (7.50-3.0))
k = 3.20 x 10 -5 m/sec
Example 4
A 0.20 m diameter well is pumped at a rate of 440
gallons/min. Observations of drawdowns taken at
1.0 m and 10.0 m distances from the centre of the
well were found to be 10.0 m and 0.50 m
respectively.
Determine the ‘K’ if the water-bearing strata
assuming that the thickness of the aquifer is 30 m.
Solution
Q = 440 gal / min.
H = 30.0 m
Dia = 0.20 m
r1 = 1.0 m
r2 = 10.0 m
S1 = 10.0 m
S2 = 0.50 m
Q = 440/ (220x60) = 0.033 m³/s
Note 1m³ = 220 imperial gallons
k=?
h1 = H - S1 = 30.0-10.0 = 20.0 m
h2 = H - S2 = 30.0-0.50 = 29.50 m
We have the formula as
Q = K ( h22 - h12 )
ln (r2/r1)
0.033 = 3.1415 x K [(29.5)2 - (20.0)2]/ ln (10.0/1.0)
k = 5.2x 10-5 m/sec
Questions
What is meant by ‘Soil Moisture’ and ‘Groundwater’?.
Explain importance of ground water
What is aquifer, aquiclude, aquitard and aquifuge?
Define Storage Coefficient and Specific Yield?
What is Darcy’s Law? Derive an expression based on
this principal for flow through porous medium. What
are limitations for validity of this law?
Differentiate between confined aquifer and unconfined
aquifer?
Write down the procedure for determining
permeability in the field by using Theim’s Equilibrium
Well Formula
Exercise
Problem 1
A well having a diameter of 0.50 m and dug in an
unconfined aquifer is. being pumped and is
delivering 0.025 m³/s. The depth of water in the well
is now 50 m that was 60 m when pumping was
started. Two observation wells are installed at 7.5 m
and 15.0 m distances from centerline of well being
pumped. The water level in the well being 7.5 m
from centerline of well is at depth of 55 m. Find the
depth in the second observation well?
Continued…
Exercise
Problem 2
A well of diameter 0.40 m is installed in a confined aquifer to
its full depth of 100 m. Its radius of influence is 275 m.
When pumped, the well delivers 0.05 m³/s at drawdown of
10 m. Find the coefficient of permeability of the aquifer?
Problem 3
A
0.30 m diameter well is pumped at a rate of 500
gallons/min. Observations of drawdowns taken at 5.0 m and
20.0 m distances from the centre of the well were found to be
15.0 m and 1.50 m respectively. Determine the ‘K’ of the
water bearing strata assuming that the thickness of the aquifer
is 50.0 m?
Continued…
Exercise
Problem 4:
Observational
wells were drilled in a cone of
depression of artesian (confined) well, being pumped
at the rate of 0.05 m³/s. The drawdown in the
observational
wells
at
5 m and 15 m were found to be 8.5 m and 3.5 m
respectively. Calculate ‘K’ of the aquifer if the
average thickness of the aquifer is 80 m?
Continued…
Exercise
Problem 5
A well is sunk to the whole of an unconfined aquifer and is pumped at a
constant rate. The drawdowns in the observational wells are measured
and the following data is generated.
Static water depth = 25 m
Q =
0.05 m³/s
Diameter of well = 1.0 m
Drawdown at 10.0 m = 1.50 m
Draw down at 20.0 m = 1.00 m
Find out the coefficient of permeability ‘k’, the diameter of circle of
influence and the drawdown in the well.
Continued…
Exercise
Problem 6:
A well with a radius of 0.30 m completely penetrates
an unconfined aquifer with k=25 m/day and water
table height from impermeable strata at the bottom
of aquifer is 45 m. The well is pumped so that the
water level in the well remains at 35 m above the
bottom of the aquifer assuming that pumping has no
effect on water table height at r = 300 m. What is
steady state well discharge?
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )