Manual of Petroleum Measurement Standards Draft Standard—Sediment and Water Continuous On-line Measurement of Water Content in Petroleum and Petroleum Products FIRST EDITION, NOVEMBER 2000 THIS DOCUMENT IS A PROSPECTIVE STANDARD FOR PROVISIONAL APPLICATION. This draft is strictly for industry review. Review of this document throughout the industry is desirable and encouraged. All comments should be sent to: American Petroleum Institute 1220 L Street, N.W. Washington, DC 20005 USA Attention: Standards Group [Measurement Coordination] There will be a review period ending two years from the publication date of this document. Comments, suggestions and corrections received during the review period will be incorporated as appropriate following normal API procedures. Manual of Petroleum Measurement Standards Draft Standard—Sediment and Water Continuous On-line Measurement of Water Content in Petroleum and Petroleum Products Measurement Coordination FIRST EDITION, NOVEMBER 2000 SPECIAL NOTES API publications necessarily address problems of a general nature. With respect to particular circumstances, local, state, and federal laws and regulations should be reviewed. API is not undertaking to meet the duties of employers, manufacturers, or suppliers to warn and properly train and equip their employees, and others exposed, concerning health and safety risks and precautions, nor undertaking their obligations under local, state, or federal laws. Information concerning safety and health risks and proper precautions with respect to particular materials and conditions should be obtained from the employer, the manufacturer or supplier of that material, or the material safety data sheet. Nothing contained in any API publication is to be construed as granting any right, by implication or otherwise, for the manufacture, sale, or use of any method, apparatus, or product covered by letters patent. Neither should anything contained in the publication be construed as insuring anyone against liability for infringement of letters patent. Generally, API standards are reviewed and revised, reaffirmed, or withdrawn at least every five years. Sometimes a one-time extension of up to two years will be added to this review cycle. This publication will no longer be in effect five years after its publication date as an operative API standard or, where an extension has been granted, upon republication. Status of the publication can be ascertained from API Measurement Coordination [telephone (202) 682-8000]. A catalog of API publications and materials is published annually and updated quarterly by API, 1220 L Street, N.W., Washington, D.C. 20005. This document was produced under API standardization procedures that ensure appropriate notification and participation in the developmental process and is designated as an API standard. Questions concerning the interpretation of the content of this standard or comments and questions concerning the procedures under which this standard was developed should be directed in writing to the Standardization Manager, American Petroleum Institute, 1220 L Street, N.W., Washington, D.C. 20005. Requests for permission to reproduce or translate all or any part of the material published herein should also be addressed to the Standardization Manager. API standards are published to facilitate the broad availability of proven, sound engineering and operating practices. These standards are not intended to obviate the need for applying sound engineering judgment regarding when and where these standards should be utilized. The formulation and publication of API standards is not intended in any way to inhibit anyone from using any other practices. Any manufacturer marking equipment or materials in conformance with the marking requirements of an API standard is solely responsible for complying with all the applicable requirements of that standard. API does not represent, warrant, or guarantee that such products do in fact conform to the applicable API standard. All rights reserved. No part of this work may be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying, recording, or otherwise, without prior written permission from the publisher. Contact the Publisher, API Publishing Services, 1220 L Street, N.W., Washington, D.C. 20005. Copyright © 2000 American Petroleum Institute FOREWORD This draft standard may involve hazardous materials, operations, and equipment. This draft standard does not purport to address all of the safety problems associated with its use. It is the responsibility of the user of this draft standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. API publications may be used by anyone desiring to do so. Every effort has been made by the Institute to assure the accuracy and reliability of the data contained in them; however, the Institute makes no representation, warranty, or guarantee in connection with this publication and hereby expressly disclaims any liability or responsibility for loss or damage resulting from its use or for the violation of any federal, state, or municipal regulation with which this publication may conflict. Suggested revisions are invited and should be submitted to Measurement Coordination, American Petroleum Institute, 1220 L Street, N.W., Washington, D.C. 20005. iii CONTENTS Page 0 INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 1 SCOPE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2 REFERENCES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 3 DEFINITIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 4 SIGNIFICANCE AND USE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 5 OWD OPERATING CRITERIA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 6 STREAM CONDITIONING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 6.1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 6.2 Velocities and Mixing Elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 7 INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 8 PACING ON-LINE WATER IN PETROLEUM DEVICE. . . . . . . . . . . . . . . . . . . . . . 3 8.1 Flow Proportional Pacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 8.2 Time Proportional Pacing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 9 AUXILIARY INSTRUMENTATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 10 INITIAL ACCEPTANCE TESTING OF OWD SYSTEMS. . . . . . . . . . . . . . . . . . . . . 3 10.1 Baseline Water Plus Injected Water Volume Method (Method 1) . . . . . . . . . . . . 4 10.2 Proven Sampling System Method (Method 2). . . . . . . . . . . . . . . . . . . . . . . . . . . 7 10.3 Average of Instantaneous Sample Method (Method 3) . . . . . . . . . . . . . . . . . . . . 8 11 CALIBRATION VERIFICATION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 11.1 Calibration of OWD System Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 11.2 On-line Spot Sample Verification Testing Procedure . . . . . . . . . . . . . . . . . . . . 10 11.3 Off-line OWD Verification Testing Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . 10 12 AUDITING AND REPORTING REQUIREMENTS FOR CUSTODY TRANSFER: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 APPENDIX A APPENDIX B APPENDIX C APPENDIX D EXAMPLE WORKSHEET FOR OWD ACCEPTANCE TESTING USING AVERAGE OF INSTANTANEOUS SAMPLES (METHOD 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 EXAMPLE CALIBRATION WORKSHEET. . . . . . . . . . . . . . . . . . . . . 13 EXAMPLE CALIBRATION SUMMARY CHART . . . . . . . . . . . . . . . 15 APPLICATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 v CONTENTS Page Figures 1 Recommended Location of OWD in a Pipeline Application . . . . . . . . . . . . . . . . . . 4 2 Typical Timing Diagram for OWD System Test . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3 Flowchart of Procedure for OWD System initial Acceptance Testing Using Method 1. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Tables 1 General Guidelines for Minimum Velocities Versus Mixing Elements (From API MPMS Chapter 8.2 - October 1995) . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 2 Typical Deviations for the OWD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 3 Typical Deviations For The OWD Average Of Instantaneous Sample Method (Method 3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Draft Standard—Sediment and Water CONTINUOUS ON-LINE MEASUREMENT OF WATER IN PETROLEUM AND PETROLEUM PRODUCTS 0 Introduction 2 References The purpose of this draft standard is to provide guidance for the continuous on-line measurement of real-time water content in petroleum and petroleum products using an Online Water in petroleum and petroleum products measurement Device (OWD) and to collect consistent data. Such measurements are of benefit in both custody transfer and process control applications. When real-time percent water measurements are made for custody transfers and some other applications (e.g. allocation measurement), there must also be a flow measurement to provide a flow-weighted average water content value. This methodology can be used in conjunction with other methods of water determination or as a stand-alone method. However, automatic sampling is essential for the following custody transfer applications: • If the on-line water measurement device used cannot effectively derive the overall integrated average water content to the required accuracy. • If other properties are require (e.g. API gravity, sediment content). • If retention samples are required. This technology should be viewed as one of several methods to determine the water in petroleum and petroleum products. The method for measuring water in petroleum and petroleum products should be selected with consideration given to installation, application, and properties of the product being measured. API Manual of Petroleum Measurement Standards Chapter 3, “Tank Gauging” Chapter 4, “Proving Systems” Chapter 5, “Metering” Chapter 6, “Metering Assemblies” Chapter 8, “Sampling” (all sections) Chapter 10, “Sediment and Water” (all sections) Chapter 20.1, “Allocation Measurement” Chapter 21.2.10, “Flow Measurement Using Electronic Metering Systems” 3 Definitions 3.1 analyzer loop: A low volume stream diverted from the main pipeline. Also known as a sample loop, slip stream or fast loop. 3.2 controller: A tertiary device (e.g. PLC, Flow Computer, etc.) that accepts inputs from an OWD, flow meter, and other necessary sensors. 3.3 dissolved water: Water in solution in petroleum and petroleum products. 3.4 emulsion: An oil/water mixture that does not readily separate. 3.5 entrained water: Water suspended in oil. Entrained water includes emulsions but does not include dissolved water. 1 Scope 3.6 flow proportional water measurement: A measurement of the water flow rate calculated from the on-line water fraction determined from the OWD measurement and the liquid flow rate through the pipe. This draft standard describes methods for the continuous on-line real time measurement of free and entrained water quantities in petroleum and petroleum products (OWD). The procedures for the proper installation, operation and calibration of on-line water in petroleum measurement devices are also described. This standard only addresses the measurement of water in petroleum liquids. This standard does not address the measurement of any solid and/or gaseous phases that may also be present. The term petroleum will be used throughout this standard to describe petroleum and petroleum products normally associated with the petroleum industry. This standard applies to water concentrations from 0.02% to 100%. In the event that there is an issue with the results of this standard and API MPMS Chapter 8.2, the referee method is API MPMS Chapter 8.2. 3.7 free water: Water that exists in a separate phase. 3.8 homogenous: Composition of a liquid is the same at all points in a vessel, container or pipeline cross section. 3.9 measurement location: Point where the OWD measures the water content of the petroleum stream. 3.10 OWD: On-line Water in petroleum and petroleum product measuring Device (referred to as a water cut monitor in other API Measurement Standards). 3.11 OWD System: An OWD system consists of one or more OWD’s, stream conditioning, other measurement 1 2 API MANUAL OF PETROLEUM MEASUREMENT STANDARDS devices (e.g. temperature, pressure, density, flow, etc.), and a controller. 3.12 pacing: Setting the measurement reporting period proportional to flow rate or time. 3.13 range: The maximum and minimum values attainable from a measurement device. When applied to an OWD, the units will be percent water by volume (e.g. 0-5% or 0-100%). 3.14 representative sample: A portion extracted from a total volume that contains the constituents in the same proportions that are present in that total volume. 3.15 sample: A portion extracted from a total volume that may or may not contain the constituents in the same proportions that are present in that total volume. 3.16 static mixer: A device that utilizes the kinetic energy of the flowing stream to achieve stream conditioning. 3.17 stream condition: The distribution and dispersion of the pipeline contents at the measurement location. 3.18 stream conditioning: The mixing of a flowing stream so that fluid constituents are homogeneously distributed and dispersed across the pipe at the measurement location. 3.19 weighted average water content: The average water content at the measurement location for the measurement period. For volumetric methods, the weighted average water content is the average of the water values measured at uniform volume intervals and is representative of the water content for the entire measurement period. 4 Significance and Use Measuring the quantity of water in petroleum liquids is critical for quantity and quality measurement. An OWD System can provide the user with information about net oil and water amounts or timely information about high levels of water that can cause process problems. The performance specification given for custody transfer applications will not normally be required for process monitoring, alarm, and control applications. If the OWD fails or the water concentration exceeds the range of the device during a custody transfer, the OWD indicated water volume is not suitable for fiscal purposes. 5 OWD Operating Criteria The following custody transfer criteria must be satisfied to obtain a representative measurement from a flowing stream, otherwise the performance of the OWD may be affected: a. For non-homogeneous mixtures such as crude oil and water, free and entrained water must be uniformly dispersed at the measurement point. b. On-line water in oil measurements must be flow proportional and provide a representative measurement of the entire parcel volume. The on-line water measurement is monitored continuously and integrated with the flow signal to calculate water content for the entire parcel. c. OWD measurements that are affected by fluid properties and operating conditions (e.g. density, temperature, pressure, salinity, viscosity, etc.) require those parameters to be measured and corrections made. Some OWD’s will automatically compensate for changes in these properties and conditions. d. The fluid must be gas free. Note: Water content is generally within a range from 0.02% to 5 percent. If the water content occasionally exceeds the 5 percent range, use an OWD system with wide-range capability. If the OWD system is not capable of the required accuracy over the expected range (for custody transfer measurement), the system must have a multiple range capability. Most OWD’s only detect water, not sediment. If necessary a separate representative sample must be taken and a test conducted to obtain the sediment value. The Karl Fischer coulometric titration is the recommended method for the analysis of samples taken in the calibration and verification of OWD’s that are used for custody transfer applications, because the test is best suited for field application and detects water only. 6 Stream Conditioning 6.1 GENERAL The OWD must be located at a point where the flowing stream is adequately mixed. The mixing may be accomplished by the flowing velocity of the fluid through the piping system and/or by adding mixing elements. Petroleum that contains free or entrained water requires sufficient mixing energy to create a representative stream at the measurement point. 6.2 VELOCITIES AND MIXING ELEMENTS Table 1, from API MPMS Chapter 8.2 based on statistical data, provides a guideline for minimum velocities versus mixing elements for pipes 5 centimeters (2 inches) in diameter and larger. Stream conditioning can be accomplished with pressure reducing valves, metering manifolds, lengths of reduced diameter piping, pumps, or piping elements (valves, elbows, tees, piping, or expansion loops). If the flow velocity at the OWD location falls below the minimum levels in Table 1, additional means, such as static mixers or power mixers, may be required. The relative position of the mixing elements and the OWD must be considered. 7 Installation Follow the manufacturer’s recommended installation guidelines. The OWD should be located where there is adequate stream conditioning. When mixers are used, the manufacturer of the mixer should be consulted for the optimum location of the OWD relative to the mixer. The OWD shall be DRAFT STANDARD—CONTINUOUS ON-LINE MEASUREMENT OF WATER CONTENT IN PETROLEUM AND PETROLEUM PRODUCTS 3 Table 1— General Guidelines for Minimum Velocities Versus Mixing Elements (From API MPMS Chapter 8.2 - October 1995) Mixing Element Piping Power Mixing Horizontal or vertical Static Mixing Vertical 0 0.305 0.61 Adequate at any velocity Static Mixing Piping elements Piping elements None Horizontal Vertical Stratified Stratified Horizontal Stratified Horizontal or vertical Stratified or not predictable Stratified 0 Minimum Pipeline Velocity, meters per second 0.91 1.22 1.52 1.83 2.13 2.44 Not Adequately dispersed predictable Not predictable Adequately dispersed Not predictable Adequately dispersed Not predictable 1 2 3 4 5 6 Minimum Pipeline Velocity, feet per second located such that accumulation of water and/or gas will not affect the measurement. See Figure 1 for recommended location of OWD in a pipeline application. For an OWD installed on an analyzer loop, the stream through the loop should be representative of the main line and should be homogenous. See Figure 1 item B2. A flow indicator must also be installed in the analyzer loop. The verification of OWD’s shall require a sample probe for drawing spot samples from the pipe for analysis. The sample withdrawn from the pipe must be representative of the flowing stream being measured for water content. For the sampling probe location position, and size, follow the guidelines for manual sampling of pipeline streams in API MPMS Chapter 8. 8 Pacing On-line Water in Petroleum Device 8.1 FLOW PROPORTIONAL PACING The preferred method for pacing an OWD is by flow meter. When flow is measured by multiple meters, the OWD should be paced by the combined total flow signal. Alternately, a separate OWD may be installed in each meter run. When transfer is by tank measurement, a flow signal must be provided to the OWD controller. This signal may be provided by an Automatic Tank Gauging system (ATG) or by an add-on flow-metering device. These devices should have a flow measurement accuracy of ± 10 percent or better, over the range of flow rates that will be experienced during the transfer. 8.2 TIME PROPORTIONAL PACING Flow proportional pacing may not be necessary for process control/alarm applications. For custody transfer applications, an OWD should operate proportionally to flow. However, time proportional pacing for custody transfer applications Adequately dispersed 7 8 may be acceptable when the flow rate variation is less than ±10 percent of the average rate. 9 Auxiliary Instrumentation Some OWD’s may use an input from one or more auxiliary measurement devices (e.g., for measuring temperature, pressure, density, salinity, viscosity, etc.) to improve water measurement accuracy. The accuracy of these auxiliary measurement devices must be verified regularly. The required frequency of these verifications (and recalibrations as necessary) is dependent upon the application and the OWD manufacturer’s recommendations. 10 Initial Acceptance Testing of OWD Systems This section describes methods for the initial acceptance testing of OWD systems through the use of various techniques for establishing the reference water content of the stream, which is then compared to the results from the OWD. Note: All components of the OWD system must be calibrated prior to initial acceptance testing. It is important that all parties agree to the method used. The following three methods are described herein: Method 1: Establish the reference water volume percent using baseline water and the injected water volume measurements. (This is the preferred method for custody transfer facilities.) Method 2: Establish the reference water volume percent using a proven sampling system. (This can result in twice the tolerance range of Method 1 depending on the original deviation for the sample system proving. Therefore, this method may not be acceptable for custody transfer facilities.) Method 3: Establish the reference water volume percent for several instantaneous samples. (This method relies exclusively 4 API MANUAL OF PETROLEUM MEASUREMENT STANDARDS Optional static mixer Metering system OWD A. OWD Position Relative to Metering System Optional static mixer Spot sample probe Optional static mixer Remote electronics OWD Pump Spot sample probe Remote electronics OWD Other, possible inputs (temp., density, flow, etc.) Other, possible inputs (temp., density, flow, etc.) B1. Inline OWD B2. OWD in Analyzer Loop (Fast Loop) 3 Pipe diameters (minimum) Remote electronics OWD 0.5 Pipe diameter (minimum) C. Preferred OWD Location Where Vertical Piping Loop is Provided Figure 1—Recommended Location of OWD in a Pipeline Application on a limited number of instantaneous samples. This method is applicable to process or production OWD installations, but may not be acceptable for custody transfer facilities.) 10.1 BASELINE WATER PLUS INJECTED WATER VOLUME METHOD (METHOD 1) Water volume injection tests are designed to prove the entire OWD system. In each test a known amount of water is injected into a known volume of petroleum of a known baseline water content. Water volume percent measured by the OWD are compared with water volume percent calculated from the injected water volume plus baseline water volume percent. 10.1.1 Test Preparation (Method 1) Preparation prior to the acceptance test should include the following procedures: 1. Determine the method and accuracy by which the water and petroleum volumes will be measured. The meter used to measure the injected water shall be calibrated. Petroleum volumes should be measured by tank gauge or meter(s) in accordance with applicable API MPMS Chapters 3, 4, 5, and 6 guidelines. 2. Locate the water injection point upstream of the elements expected to produce the stream conditioning for the OWD DRAFT STANDARD—CONTINUOUS ON-LINE MEASUREMENT OF WATER CONTENT IN PETROLEUM AND PETROLEUM PRODUCTS 5 Purge Baseline Sample Activity Water Injection To Allow for Lag and Spreading Water Arrives Test Period Baseline Sample Time Note: Times are calculated based on minimum oil flow rate and distance between the injection and the sample point. Figure 2—Typical Timing Diagram for OWD System Test system. Be aware of potential traps in the piping that may prevent all of the injected water from passing the measurement point. Care should be taken to ensure that the location and manner in which water is injected does not contribute additional mixing energy, which could distort the test results. Equipment or facilities used to inject water should be in accordance with local safety practices. 3. Review the normal operating conditions of the pipeline in terms of flowrates and petroleum types. Select the most common, worst-case conditions to test the OWD. The worst case is usually the lowest normal flow rate and the lowest viscosity (lowest density or highest API gravity) petroleum normally received or delivered. However, a very high viscosity oil may be the “worst case”. 4. Determine a point where samples can be drawn downstream of the stream conditioning. Samples must be homogeneous and representative of the flowing stream. These samples will be used for baseline water determination and possibly for spot samples during the test period. Sample probe should meet the requirements described for the probe design in API MPMS Chapter 8.1 or 8.2. 10.1.2 Test Procedure (Method 1) 1. Purge the system at a high flow rate to displace free water that may be lying in the pipeline system upstream of the OWD. 2. Adjust the flow rate for the test. Baseline Steps 3. Determine the baseline water content per API MPMS Chapter 10 (Karl Fisher coulometric titration or distillation) and calibrate the OWD as listed in the steps that follow. a. Draw a sample from sample point. b. Determine and record the OWD reading at the time the sample is drawn. c. Determine and record the water volume percent of the sample. d. Repeat steps a through c for 4 more samples, using even time intervals between samples. e. Average the 5 OWD readings. f. Average the 5 sample analysis results. g. Compare average of sample analysis results to average of OWD readings. h. Adjust the current OWD reading by the difference between the averages. i. Repeat steps a through c one time to verify the OWD has been calibrated properly. j. Average the 6 sample analysis results to determine the baseline water volume percent. Typical timing for Method 1 is shown on Figure 2. A flowchart for the test procedure is shown on Figure 3 and the details follow the figure. Notes: 10.1.2.1 Test Procedure Details (Method 1) 1. The range (highest value versus lowest value) of the sample water volume percent should be within 0.1% to have a stable baseline. Note: Following method is described for Custody Transfer with water volume percents up to 5%. 2. The variation in the difference between the paired results (sample n – OWD n) must be within a tolerance of ±0.05 water volume %. 6 API MANUAL OF PETROLEUM MEASUREMENT STANDARDS Perform Water Injection Purge System At High Flowrate No Record Initial Petroleum Volumes (Tank Gauge Or Meter Reading) Adjust Flowrate For Test Determine Baseline Water Content Calculate Deviation Between OWD Measured And Calculated Actual. Two Consecutive Tests Meeting Criteria? Record Initial Water Flow Meter Reading. Yes Test Is Complete Turn Water On And Adjust Injection Rate. Draw Sample Determine OWD Reading At Time Of Sample Draw Vary Water Injection Rates To Simulate The Various Percentages Of Water To Be Expected. Run one more pass to confirm No No Determine Water Content Of Sample Turn Water Off And Record Water Flow Reading. Allow Time For Injected Water To Pass The OWD. Simultaniously Stop/Record Test Data Completed 5 Separate Samples? Yes Is Avg OWD Equal To Avg Sample? No Adjust OWD To Match Sample Analysis (to be done on initial series only) Confirm Baseline Stability By Determining A Final Baseline And Comparing It To Initial Baseline. Yes Range Of Sample Values Within 0.1%? No Baseline Is Not Stable. Stabilize The System And Try Again. Is Baseline Stable? Yes Average The Sample Analysis To Determine The Baseline Water Volume Percent Final Baseline For This Test? No If Baseline Continues To Fluctuate, Stop Test And Correct. Yes Yes Figure 3—Flowchart of Procedure for OWD System initial Acceptance Testing Using Method 1 DRAFT STANDARD—CONTINUOUS ON-LINE MEASUREMENT OF WATER CONTENT IN PETROLEUM AND PETROLEUM PRODUCTS Water Injection Steps Note: Approximately one hour is required for the water injection 4. Record the initial petroleum volume by tank gauge or flow meter reading and initialize the flow weighted calculation device (e.g. flow computer), i.e. open the ticket. 5. Record the initial water flow meter reading; turn the water on and adjust the injection rate. • During the test period, adjust the injection rate to simulate the various percentages of water to be expected, as agreed between parties. (Note: Ensure the percent water injected is within the capabilities of the OWD.) 6. Turn the water off and record the water flow meter reading. 7. Continue taking readings from the OWD until the injected water is calculated to have passed the measurement device. 8. Stop the collection of the test data, simultaneously record the final petroleum volume by tank gauge or meter reading and finalize the flow weighted calculation device (e.g. flow computer), i.e. close the ticket. 9. Confirm Baseline stability by repeating Step 3 (excluding 3.h). • The difference in the percent water in the initial and final baseline shall be less than or equal to 0.1 % (Initial Baseline – Final Baseline ≤ ±0.1%) Note: For a water content >5%, the difference in the percent water in the initial and final baseline shall be less than or equal to 4% of water reading (e.g., if baseline water is 10% the allowable difference is (10% x 4% = 0.4%), which is maximum baseline deviation.) • If the difference between initial and final baseline results is greater than 0.1 percent (or 4.0 percent of reading for a water content in the range of >5%) return to step 4. If the baseline continues to fluctuate, stop test and take corrective action. 10. Using the following equation, calculate the deviation between the water in the test readings minus the readings in the baseline compared to the amount of water injected. DEV = (Wtest – Wbaseline) – Winjected Where: DEV = DEVIATION (volume %) Wtest = water in test readings (OWD value in volume %) Wbaseline = basline water adjusted to test conditions (volume %) = Wavg x (TOV – V)/TOV Wavg = average of all OWD measured baseline results, water in (volume %) 7 TOV = total observed volume (test oil plus injected water) that passes the measurement probe (barrels) V = volume of injected water in barrels Winjected = water injected during test (volume %) = V/TOV x 100 11. Repeat steps 3 through 14 until two consecutive tests are within the acceptable deviation limits (e.g. see Table 2). 10.1.3 Typical Acceptance Criteria (Method 1) Baseline Acceptance a. Custody Transfer Applications: The difference in the percent water in the initial and final baseline shall be 0.1% or less for a water content range of 0.02% to 5%. (The difference in the percent water in the initial and final baseline shall be 4% of reading or less for a water content range of >5% to 100%.) b. Non-Custody Transfer Applications: The acceptable difference in the percent water in the initial and final baseline should be agreed by all the parties. Typically the differences should be 2% or less for a water content range of 0% to 100%. System Acceptance a. OWD System Acceptance Custody Transfer: The deviation between the water content from the OWD and the known baseline plus injected water is within the allowable deviation limits (e.g. see Table 2), for two consecutive tests. b. OWD System Acceptance Non-Custody Transfer: The deviation between the water content from the OWD and the known baseline plus injected water should be agreed by all the parties, for two consecutive tests. 10.2 PROVEN SAMPLING SYSTEM METHOD (METHOD 2) Compare the OWD System results to an existing sampling system results in normal operations, proven for the typical grades of petroleum and the conditions to be encountered. (If the conditions have changed since the last proving of the sampling system, the existing system may no longer meet the requirements of API MPMS Chapter 8.2 and any comparison to an OWD could introduce a bias.) The number of measurement periods should be agreed upon between the parties involved, with a minimum of five measurement periods. Acceptability is checked by comparing the flow weighted average of the OWD measurements to the proven sampling system test results over the same measurement period. Deviation between the OWD and the proven sampling system results must be within the deviation limits agreed to by all parties, e.g. see Table 2, based on the original sample system acceptance test (tank gauge or meter). An optional consideration would be 8 API MANUAL OF PETROLEUM MEASUREMENT STANDARDS Table 2—Typical Deviations for the OWD Typical Deviation Total Water (Wbaseline + Winjected) 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.0 to 100 10 25 50 75 100 Notes: Using Tank Gauges 0.13 0.15 0.16 0.17 0.18 0.19 0.20 0.21 0.22 0.23 Using Meters 0.09 0.11 0.12 0.13 0.14 0.15 0.16 0.17 0.18 0.19 0.40 1.00 2.00 3.00 4.00 0.40 1.00 2.00 3.00 4.00 % of Reading 3.8 4.0 4.0 4.0 4.0 4.0 4.0 1. Basis for the above Table 2 and the following notes is API MPMS 8.2 (October 1995) Table 1. 2. The reference to tanks or meters refers to the method used to determine the volume of crude oil or petroleum in the test. 3. Deviations shown reflect use of the Karl Fischer test method described in API MPMS Chapter 10.9 for water. 4. Interpolation is acceptable for water concentrations between values shown in the table. For example, if the total water is 2.25 percent, the allowable deviation using tank gauges would be 0.175 percent, and 0.135 percent if using meters. 5. This table is based, in part, on statistical analysis of a database consisting of 36 test runs from 19 installations. Due to the number of data, it was not possible to create separate databases for the method of petroleum volume determination using tank gauges and using meters. Therefore, it was necessary to treat the data as a whole for analysis. The database is valid for the water range 0.5 percent to 2.0 percent. The reproducibility standard deviation calculated based on the data, at a 95 percent confidence level, has been used for the values “Using Meters” shown in the table in the water range 0.5 percent to 2.0 percent. Assigning these values to the meter is based on a model that was developed to predict standard deviations for volume determinations by tanks and meters. Values shown in the table “Using Tank Gauging” in the range 0.5 percent to 2.0 percent were obtained by adding 0.04 percent to the values "Using Meters" in this water range. The value of 0.04 percent was derived from the aforementioned model as the average bias between tank and meter volume determinations. As there is insufficient test data for water levels over 2.0 percent, values shown in the table above 2.0 percent have been extrapolated on a straight-line basis using the data in the 0.5 percent to 2.0 percent range. to inject water at various rates (one rate per measurement period) to verify the OWD system performance over a range of water contents expected during normal operation. 10.3 AVERAGE OF INSTANTANEOUS SAMPLE METHOD (METHOD 3) This method is an example of an alternate means to test an OWD. It can be used when a certified automatic sampling system is not available, flowrate is unknown, and/or baseline water content may vary widely (e.g., well test environments or high water content). This test method shall not be used when test methods 10.1 (water injection test method) or 10.2 (direct comparison with an existing certified sampling system) can be utilized. The intent of this test method is to accomplish the following: 1. To evaluate if the average of the OWD instantaneous readings are reflective of the average of the instantaneous samples, within the allowable deviation limits of Table 3. 2. To evaluate how well the OWD accurately reflects the variations in water content when compared to actual sample results during the water injection period. If the water content normally varies it may not be necessary to inject additional water. 10.3.1 Test Preparation (Method 3) Preparation prior to the acceptance test should include the following procedures: 1. Locate the water injection point upstream of the elements expected to produce the stream conditioning for the OWD DRAFT STANDARD—CONTINUOUS ON-LINE MEASUREMENT OF WATER CONTENT IN PETROLEUM AND PETROLEUM PRODUCTS Table 3—Typical Deviations For The OWD Average Of Instantaneous Sample Method (Method 3) Average (Instantaneous Sample) Typical Deviation 0.1 0.13 1.0 0.15 1.5 0.16 2.0 0.17 2.5 0.18 3.0 0.19 3.5 0.20 4.0 0.21 4.5 0.22 5.0 0.23 > 5.0 to 100 10 0.40 25 1.00 50 2.00 75 3.00 100 4.00 Note: This table is based on the values in Table 2. system. Be aware of potential traps in the piping that may prevent all of the injected water from passing the measurement point. Care should be taken to ensure that the location and manner in which water is injected does not contribute additional mixing energy, which would distort the test results. Equipment or facilities used to inject water should be in accordance with local safety practices. 2. Review the normal operating conditions of the pipeline in terms of flowrates and crude types. Select the most common, worst case conditions to test the OWD. The worst case is commonly the lowest normal flow rate and the lowest relative density (highest API gravity) petroleum normally received or delivered. 3. Care should be taken in selecting a sample draw location, at a point where the flow is a homogeneous mixture and representative of the flowing stream. Additionally this location should be in close proximity to the OWD. Whenever possible the sample should be taken from a sample draw probe. 10.3.2 Test Procedure (Method 3) The purpose of the Baseline test is to establish initial accuracy and repeatability of the OWD. 1. Purge the system at a sufficiently high flow rate to displace free water that may be lying in the pipeline system upstream of the OWD. 2. Draw-off an initial baseline sample and compare with the OWD instantaneous reading when the sample was drawn. 3. Determine the baseline water volume percent and calibrate the OWD per the Baseline Steps in Method 1 (Section 10.1.2.3). 9 4. Average the OWD readings and sample results to define the deviation of the Baseline. 5. The difference between the average OWD and the average sample results must be within the tolerances agreed to by the parties, e.g. see Table 3. 6. Record the initial water flow meter reading; start the water injection and adjust the injection rate. A water flow meter allows the operator to verify the water volume, injection flow rate and evaluate the corresponding OWD deviations. The purpose of the injection portion of this test is to prove the accuracy and repeatability of the OWD during varying water conditions. 7. Approximately one hour is required for the water injection. • During the injection period draw off 12 samples at equal time intervals (approximately 5-minute intervals) recording the OWD instantaneous reading at the same time (as in Step 3). • Water injection rate can be varied to evaluate different levels of water content. 8. Stop the water injection and record the water flow meter reading. 9. Complete the worksheet. (See Appendix I) • Calculate the average of the sample results. • Calculate the average of the OWD results. • Percent difference is (Average sample result – Average OWD result). • Refer to Table 3 for allowable deviation. 10. Repeat steps 3 through 9 until the results from two consecutive tests meet the deviation in Table 3. 11. If the system fails more than three times stop test and take corrective action. Note: If the amount of oil available prevents tests of the above duration, the time period may be reduced as necessary. However, it is recommended that the number of samples in each test be maintained. 11 Calibration Verification An on-going OWD system calibration verification program shall be established . The calibration of all essential components of the OWD system shall be verified routinely. Initially, each OWD system shall be inspected and its calibration verified frequently. If operating experience confirms stable performance, the calibration verification schedule may be extended. 11.1 CALIBRATION OF OWD SYSTEM COMPONENTS Users should consult the manufacturers’ recommendation on calibration of the OWD system components. A representative tolerance for volume custody transfer applications is ± 0.1 degrees F and ± 0.5 degrees API or less. Generally, calibration 10 API MANUAL OF PETROLEUM MEASUREMENT STANDARDS is extremely important, since each measurement depends on another. a. Calibrate all instruments used in the measurement calculation b. Calibrate the OWD to the deviation agreed to by the parties, e.g., see Table 2. All test equipment used in the calibration shall be traceable to NIST, or appropriate agency. All calibration records of test equipment should be maintained and available for review. (Examples are; date of last calibration, reagent change date, date any equipment was replaced.) All calibration records and performance records of the OWD system must be available for review by customers involved in measurement for the purposes of custody transfer. 11.2 ON-LINE SPOT SAMPLE VERIFICATION TESTING PROCEDURE This testing procedure is used to regularly verify the OWD system calibration at the existing fluid/operating conditions. The flowing stream must be homogeneous at the test sample draw location. Draw a test sample, per API MPMS Chapter 8.1 and 8.3, from the location shown in 11.1.1 item 4 and simultaneously record the reading of the OWD (water content in volume percent). Analyze the test sample per API MPMS Chapter 10 and compare the results. Results must fall within the deviation agreed to by the parties, e.g. see Table 2. If results do not meet the agreed to tolerance, perform the calibration procedure below. • Record the OWD water volume percent reading at the time the sample is drawn • Determine the water volume percent of the sample analysis • Compare the OWD reading to the sample analysis • Adjust the OWD to match the sample analysis • Repeat steps to verify calibration Record, sign and date the Calibration Worksheet. (See example in Appendix B). Maintain a summary chart of test results to show repeatability and drift over time (See example in Appendix C). 11.3 OFF-LINE OWD VERIFICATION TESTING PROCEDURE Periodically a closed loop system may be used to verify the OWD accuracy over a range of water/petroleum concentrations. Such a loop would have a known volume in which predetermined amounts of petroleum (or petroleum products) and water are mixed to create desired concentrations for testing. The closed loop can be any of the following: The manufacturer’s test loop, a portable system, or a permanent part of the OWD system installation. Having the loop at the OWD installation site makes it convenient to test using liquid from the flowing stream. Important Considerations: • The closed loop must be well insulated to prevent internal condensation of water on the pipe wall. • The closed loop must have a temperature control (chiller/heat exchanger) to prevent temperature build up due to pumping the fluid in a small, closed loop. 12 Auditing and Reporting Requirements For Custody Transfer: The OWD System should indicate when it’s range is exceeded. When the OWD system is used in a custody transfer electronic measurement system, the user must comply with the standards as defined in API MPMS Chapter 21.2, Flow Measurement Using Electronic Metering Systems, Section 10, Auditing and Reporting Requirements. APPENDIX A—EXAMPLE WORKSHEET FOR OWD ACCEPTANCE TESTING USING AVERAGE OF INSTANTANEOUS SAMPLES (METHOD 3) Date: Avg. Temp.: Start Time: Avg. Gravity: End Time: Baseline Sample # Time (hh:mm:ss) Sample Result (Vol % Water) OWD Result (Vol % Water) Time (hh:mm:ss) Sample Result (Vol % Water) OWD Result (Vol % Water) 1 2 3 4 5 6 Baseline Average Water Injection Test Sample # 1 2 3 4 5 6 7 8 9 10 12 Averages Results % Difference Acceptance: Pass/Fail BY: DATE: 11 APPENDIX B—EXAMPLE CALIBRATION WORKSHEET Instrument: Mfg: S/N: Model: Location: Date: I. Calibrate Densitometer (if used) before proceeding to the next step. (Use Densitometer Calibration Worksheet) II. Temperature Adjust: Test Equipment Used: Mfg: S/N: Date Calibrated: Sample ID Time Displayed Time Measured Temp. Temp. Deviation Current Temp. Adjust New Temp. Adjust III. OWD Calibraion: Test Method Used: Mfg: Model & S/N: Date Calibrated: Sample ID Time Displayed Contents Measured Content Deviation Current Cal Factor New Cal Factor Calibrated By: Date: Agency: Witness By: Date: Agency: 13 Index Reference Voltage 14 API MANUAL OF PETROLEUM MEASUREMENT STANDARDS Company Name Densitometer Calibration Worksheet Mfg: Instrument: S/N: Model: Location: Date: I. Temperature Adjust: Follow Manufacturer’s calibration procedures to calibrate temperature for densitometer before proceeding to the next step. II. Density Adjust: Test Equipment Used: Mfg: S/N: Date Calibrated: Sample ID Time Displayed Temp. Observed Density Measured Density Deviation Current Cal Factor A Calibrated By: Date: Agency: Witness By: Date: Agency: New Cal Factor A APPENDIX C—EXAMPLE CALIBRATION SUMMARY CHART Company Name OWD Calibration Summary Instrument: Mfg: S/N: Model: Location: Date: Enter final results of each calibration onto the Summary Page. This will help you spot trends Test Number Test Date Test Time Displayed Contents Measured Content 15 Deviation Current Cal Factor New Cal Factor Index Reference Voltage APPENDIX D—APPLICATIONS OWD’s may be used in different custody and non-custody applications. Below are some examples of common applications total production is allocated back to the individual wells and facilities. This application may also include the use of OWD’s on well test separators. D.1 Pipeline D.3.2.2 Well Test Pipeline water content is generally within a range from 0.02% to 5%. If the water content occasionally exceeds the 5% range, use an OWD system with wide range capability. If the OWD system is not capable of required accuracy over the expected range (for custody transfer measurement), the system must have a multiple range capability. OWD’s can be utilized as part of well test facilities. After the gas is flashed in the separator, the total liquid can be measured and then the OWD used to quantify the amount of water in the stream. Often these streams will have high water content. D.3.2.3 Water Separator Facilities D.2 Marine OWD’s can be used in production facilities to monitor the operation of the water separators to maximize separation while also maximizing throughput. Applies to portable (shipboard) or stationary systems (refer to API MPMS Chapter 8.2.9 for more detail). Installation requirements for shipboard OWD’s are the same as those discussed in API MPMS Chapter 8.2.17. D.3.2.4 Crude Oil Gathered by Tank Truck OWD’s can be mounted on production gathering trucks to monitor the water content of crude oil loaded onto or discharged from the trucks. Alternatively, OWD’s can be ground mounted at the crude oil discharge metering points. The main concern with this application is the range of crude oil types encountered. D.3 Process Depending on the actual process application, the installation, calibration, and certification procedures for an OWD may be relaxed from the requirements for custody transfer. D.3.1 REFINING OWD’s can be used to monitor the water content of crude oil or other feedstocks to minimize process upsets, damage to equipment, and contamination of catalysts in refinery operations. The operation of equipment, like desalters, can be monitored and optimized with an OWD. D.3.3 MARKETING OWD’s can be utilized to monitor the water content of petroleum products in a marketing terminal to assure that water in excess of specifications is not shipped in or out of the facility. The OWD can be used to quantify the water transferred or as an indicator to stop a transfer if water above a specified level is detected. D.3.2 PRODUCTION D.3.2.1 Allocation Measurement OWD’s can be utilized to measure the total dry oil from various production facilities that would be used when the 17 American Petroleum Institute Publications Order Form - 2000 Available through Global Engineering Documents Phone Orders: 1-800-854-7179 (Toll-free in the U.S. and Canada) • 303-397-7956 (Local and International) • Fax Orders: 303-397-2740 Online Orders: www.global.ihs.com Date: ❏ API Member (Check if Yes) Invoice To (❏ Check here if same as “Ship To”) Ship To (UPS will not deliver to a P.O. Box) Name: Name: Title: Title: Company: Company: Department: Department: Address: Address: City: State/Province: City: State/Province: Zip/Postal Code: Country: Zip/Postal Code: Country: Telephone: Telephone: Fax: Fax: E-Mail: E-Mail: Quantity Order Number H30201 H30202 H30203 H30204 H10052 H10062 H30207 H30208 H30210 ❏ Payment Enclosed CH 10.1, Determination of Sediment in Crude Oils & Fuel Oils by the Extraction Method CH 10.2, Determination of Water in Crude Oil by Distillation CH 10.3, Determination of Water & Sediment in Crude Oil by the Centrifuge Method (Laboratory Procedure) CH 10.4, Determination of Sediment & Water in Crude Oil by the Centrifuge Method (Field Procedure) CH 10.5, Determination of Water in Petroleum Products & Bituminous Materials by Distillation CH 10.6, Determination of Water & Sediment in Fuel Oils by the Centrifuge Method (Laboratory Procedures) CH 10.7, Standard Test Method for Water in Crude Oil by Karl Fischer Titration (Potentiometric) CH 10.8, Standard Test Method for Sediment in Crude Oil by Membrane Filtration CH 10.9, Standard Test Method for Water in Crude Oils by Coulometric Karl Fischer Titration ❏ P.O. No. (Enclose Copy) ❏ MasterCard Credit Card No.: Name (As It Appears on Card): Expiration Date: Signature: Unit Price Total $ 50.00 $ 50.00 $ 50.00 $ 50.00 $ 50.00 $ 50.00 $ 50.00 $ 50.00 $ 50.00 Subtotal Applicable Sales Tax (see below) ❏ Charge My Global Account No. ❏ VISA SO* Title ❏ American Express ❏ Discover Rush Shipping Charge (see below) Shipping and Handling (see below) Total (in U.S. Dollars) *To be placed on Standing Order for future editions of this publication, place a check mark in the SO column and sign here: Pricing and availability subject to change without notice. Mail Orders – Payment by check or money order in U.S. dollars is required except for established accounts. State and local taxes, plus 5% for shipping and handling, must be added. Send mail orders to: API Publications, Global Engineering Documents, 15 Inverness Way East, M/S C303B, Englewood, CO 80112-5776, USA. Purchase Orders – Purchase orders are accepted from established accounts. Invoice will include actual freight cost, an $8.00 handling fee, plus state and local taxes. Telephone Orders – If ordering by telephone, an $8.00 handling fee and actual freight costs will be added to the order. Sales Tax – All U.S. purchases must include applicable state and local sales tax. Customers claiming tax-exempt status must provide Global with a copy of their exemption certificate. Shipping (U.S. Orders) – Orders shipped within the U.S. are sent via traceable means. Most orders are shipped the same day. Subscription updates are sent by First-Class Mail. Other options, including next-day service, air service, fax transmission, and electronic delivery are available at additional cost. Shipping (International Orders) – Standard international shipping is by air express courier service. Subscription updates are sent by World Mail. Normal delivery is 3-4 days from shipping date. Rush Shipping Fee – In addition to the carrier charges, the following charges will be added: Next Day Delivery orders placed prior to 2:00 p.m. MST - $10.00 / Next Day Delivery orders placed after 2:00 p.m. MST - $20.00 (if time is available for order processing) Returns – All returns must be pre-approved by calling Global’s Customer Service Department at 1-800-624-3974 for information and assistance. There may be a 15% restocking fee. Special order items, electronic documents, and age-dated materials are non-returnable. The American Petroleum Institute provides additional resources and programs to industry which are based on API Standards. For more information, contact: • Training/Workshops Ph: 202-682-8490 Fax: 202-962-4797 • Inspector Certification Programs Ph: 202-682-8161 Fax: 202-962-4739 • American Petroleum Institute Quality Registrar Ph: 202-682-8574 Fax: 202-682-8070 • Monogram Licensing Program Ph: 202-962-4791 Fax: 202-682-8070 • Engine Oil Licensing and Certification System Ph: 202-682-8233 Fax: 202-962-4739 To obtain a free copy of the API Publications, Programs, and Services Catalog, call 202-682-8375 or fax your request to 202-962-4776. Or see the online interactive version of the catalog on our web site at www.api.org/cat. Helping You Get The Job Done Right. SM 01.21.00 11/00 Additional copies available from API Publications and Distribution: (202) 682-8375 Information about API Publications, Programs and Services is available on the World Wide Web at: http://www.api.org Order No. H00005
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )