ACUSON X300 Upgrade Instructions System Cardio-Vascular Option Upgrade This document is valid for: ACUSON X300, ACUSON X300 PE Document Version / Disclaimer / Copyright 2 Document Version Siemens reserves the right to change its products and services at any time. In addition, manuals are subject to change without notice. The hardcopy documents cor‐ respond to the version at the time of system delivery and/or printout. Versions to hard‐ copy documentation are not automatically distributed. Please contact your local Siemens office to order a current version or refer to our website http://www.healthcare.siemens.com. Disclaimer Siemens provides this documentation “as is” without the assumption of any liability under any theory of law. The content described herein shall be used by qualified personnel who are employed by Siemens or one of its affiliates or who are otherwise authorized by Siemens or its affiliates to use such documents. Assemblers and other persons who are not employed by or otherwise directly affiliated with or authorized by Siemens or one of its affiliates are not entitled to use this documen‐ tation without prior written authority. Copyright “© Siemens, 2011” refers to the copyright of a Siemens entity such as: Siemens Healthcare GmbH - Germany Siemens Aktiengesellschaft - Germany Siemens Shenzhen Magnetic Resonance Ltd. - China Siemens Shanghai Medical Equipment Ltd. - China Siemens Medical Solutions USA Inc. - USA Siemens Healthcare Diagnostics Inc. - USA and/or Siemens Healthcare Diagnostics Products GmbH - Germany ACUSON X300 US11-100.892.01.05.02 09.11 Page 2 of 30 Ultrasound © Siemens, 2011 Restricted Table of Contents 1 Cardio-Vascular Option Upgrade 1.1 1.2 2 2.2 2.3 3.2 3.3 4.2 4.3 6 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1.1 Workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1.2 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.1.3 Install the RC-Daughter Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install the ECG Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.1 Workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.2 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3.1.3 Install the RC-Daughter Board . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install the ECG Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17 17 17 18 19 22 22 26 28 Changes to Previous Version . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . US11-100.892.01.05.02 09.11 12 12 12 13 14 16 17 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.1 Workflow . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.2 Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.1.3 RC-Daughter Board Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . Install the Advanced ECG Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Install Axius EF License . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4.3.1 Prepare the system for the license load . . . . . . . . . . . . . . . . . . . . 4.3.2 Verification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . List of Hazard IDs © Siemens, 2011 Restricted 7 7 7 8 9 11 12 Changes to Previous Version 5.1 4 6 6 7 Cardio-Vascular Option Upgrade r5.0 and Above 4.1 5 Option Upgrade. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Upgrade Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.2.1 General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cardio-Vascular Option Upgrade r3.0/4.0 3.1 4 4 Cardio-Vascular Option Upgrade r1.0/2.0 2.1 3 3 28 29 Page 3 of 30 Ultrasound ACUSON X300 4 1 Cardio-Vascular Option Upgrade 1.1 Option Upgrade The Cardio-Vascular Option enables steerable continuous-wave Doppler and an ECG Mod‐ ule for cardiac and vascular applications that require these fundamental capabilities. Use this option upgrade procedure to add the following functions to an ACUSON X300 systems. Description Sales Num‐ System ber Advanced CV Field Upgrade, X300 10427822 Upgrade Contents X300 r5.0/6.0/7.0 or higher (Availa‐ ble with Serial Number 315001 or higher). n n n n n X300 5.0 physio module (10429496 for SATA, 10137045 for PATA) 10348228 Axius EF license 10348502 RC-Daughter Board 10136930 Low noise kit for cardiac option 10563956 SW Install set, X300 r6.0 ECG cable shall be selectable among USA, Europe, but not included in the upgrade op‐ tion kits. ACUSON X300 US11-100.892.01.05.02 09.11 Page 4 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade 1 Description Sales Num‐ System ber CV Field Up‐ grade, X300 10349032 Upgrade Contents X300 r3.0/4.0 (available with Se‐ rial Number 313001 - 315000) n n n 08659778 ECG Module 10348502 RC-Daughter Board ECG Electrode Disp, 50 pcs Selectable among USA, Eu‐ rope, and Europe Special ECG cables, but not included in the upgrade option kits. Basic CardioVascular Up‐ grade, X300 10429363 X300 r1.0/2.0 (Available with Se‐ rial Number 310001 - 324000) n n n n 08659778 Assy. ECG Mod‐ ule 10131950 RC-Daughter board ECG Electrode Disp. 50 pcs 10348279 SW Install set, X300 r2.0 Selectable among USA, Eu‐ rope, and Europe Special ECG cables, but not included in the upgrade option kits. n Cardiac imaging capability using Cardiac transducers n ECG and Physio signal acquisition and display n ECG trigger facility n Modified User Interface n Auxiliary CW transducer operation © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 5 of 30 Ultrasound ACUSON X300 5 6 1 Cardio-Vascular Option Upgrade 1.2 Upgrade Description The upgrade involves the replacement/addition of the following: 1.2.1 n RC Daughter Board n ECG Module n ECG Electrode Disp 50pc. n ECG Cable General Information The person doing the upgrade should have a disk at the current revision of the system in case of problems. ACUSON X300 US11-100.892.01.05.02 09.11 Page 6 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade r1.0/2.0 2 2.1 Overview Follow the instructions below to install the Cardio-Vascular option to the ACUSON X300 PE systems r1.0 and r2.0. This upgrade involves the replacement and/or addition of the RC-Daughter Board and the ECG Module. 2.1.1 Workflow 1. Install the RC-daughter Board 2. Install the ECG Module 3. Verification 2.1.2 Requirements 2.1.2.1 Required Materials CV Option Field Upgrade, 10429363 2.1.2.2 Required Tools Standard tool kit 2.1.2.3 Required Time Upgrading the ACUSON X300 takes approximately one hour. 2.1.2.4 System Preparation Perform the EM module test (BIST) to ensure the system is fully operational before pro‐ ceeding to the upgrade procedure. 1. Power Off the system and set the Main switch to Off. Leave the power cord connec‐ ted to the wall outlet. WARNING The X300 system contains hazardous voltages that can range from 90 VAC to 246 VAC and cause serous injury. Only authorized service personnel are permitted to remove protective covers and access the energized components of this system. © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 7 of 30 Ultrasound ACUSON X300 7 8 2 Cardio-Vascular Option Upgrade r1.0/2.0 2. Remove the right, left and rear covers. Refer to ( System Covers / US11-104.841.01). 2.1.3 Install the RC-Daughter Board 1. Remove the EM cover. 2. Remove the RC board. Refer to ( Remove the Boards / US11-104.841.01). 3. Carefully install the RC-Daughter Board to the removed RC Board and fasten with (2) screws. Refer to ( Install the RC Daughter Board / US11-104.841.01). Fig. 1: RC Board with EC-Daughter Board Shown 4. Place the RC board into the system. Refer to ( Install the E Module and Boards / US11-104.841.01). ACUSON X300 US11-100.892.01.05.02 09.11 Page 8 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade r1.0/2.0 2 2.2 Install the ECG Module The ECG Module is the same as the Physio Module. 1. Remove the CD/DVD-R/RW and the ECG bracket from the system. Refer to ( Removing the CD/DVD-R/RW and ECG / US11-104.841.01). Replace the existing label with the ECG label on the ECG module bracket. Fig. 2: Example of ECG label 2. Connect the ECG module to the ECG module bracket with the provided (4) screws. Fig. 3: Location of four screws on the ECG module bracket and the ECG module © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 9 of 30 Ultrasound ACUSON X300 9 10 2 Cardio-Vascular Option Upgrade r1.0/2.0 3. Connect the ECG module to the inter-board. Fig. 4: ECG Module connection with Interboard 4. Place the DVD-R/RW and the ECG module bracket into the system. Refer to ( Install the CD/DVD-R/RW and ECG / US11-104.841.01). 5. Install the front, left and right covers on the system. Refer to ( System Cov‐ ers / US11-104.841.01). 6. Set the Main switch to On and power On the system. Wait for the system to fully boot-up. 7. Power Off the system and set the Main switch to Off. ACUSON X300 US11-100.892.01.05.02 09.11 Page 10 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade r1.0/2.0 2 2.3 Verification 1. Power On the system and wait for the completion of boot-up. 2. Press Preset key to display the Preset screen 3. Select Service from the left menu pane. 4. Select Service. The Service Authentication screen displays. 5. Log onto the system service software using a customer level or SAL 7. Click OK. The Service Main Menu displays. 6. Select Configuration. 7. Select Hardware. 8. Scroll down the window and check if the replaced/installed boards are displayed with their part number, Serial number and Revision level correctly. Fig. 5: Hardware Details Window Shown © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 11 of 30 Ultrasound ACUSON X300 11 12 3 Cardio-Vascular Option Upgrade r3.0/4.0 3.1 Overview Follow the instructions below to install the Cardio-Vascular option to the ACUSON X300 PE systems r3.0 and r4.0. This upgrade involves the replacement and/or addition of the RC-Daughter Board and the ECG Module. 3.1.1 Workflow 1. Install the RC-daughter Board 2. Install the ECG Module 3. Verification 3.1.2 Requirements 3.1.2.1 Required Materials CV Option Field Upgrade, 10349032 3.1.2.2 Required Tools Standard tool kit 3.1.2.3 Required Time Upgrading the ACUSON X300 takes approximately one hour. 3.1.2.4 System Preparation Perform the EM module test (BIST) to ensure the system is fully operational before pro‐ ceeding to the upgrade procedure. 1. Power Off the system and set the Main switch to Off. Leave the power cord connec‐ ted to the wall outlet. WARNING The X300 PE system contains hazardous voltages that can range from 90 VAC to 246 VAC and cause serous injury. Only authorized service personnel are permitted to remove protective covers and access the energized components of this system. ACUSON X300 US11-100.892.01.05.02 09.11 Page 12 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade r3.0/4.0 3 2. Remove the right, left and rear covers. Refer to ( System Covers / US11-104.841.01). 3.1.3 Install the RC-Daughter Board 1. Remove the EM cover. 2. Remove the RC board. Refer to ( Remove the Boards / US11-104.841.01). 3. Carefully install the RC-Daughter Board to the removed RC Board and fasten with (2) screws. Refer to ( Install the RC Daughter Board / US11-104.841.01). Fig. 6: RC Board with RC-Daughter Board 4. Place the RC board into the system. Refer to ( Install the E Module and Boards / US11-104.841.01). © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 13 of 30 Ultrasound ACUSON X300 13 14 3 Cardio-Vascular Option Upgrade r3.0/4.0 3.2 Install the ECG Module The ECG Module is the same as the Physio Module. 1. Remove the CD/DVD-R/RW and the ECG bracket from the system. Refer to ( Removing the CD/DVD-R/RW and ECG / US11-104.841.01). Replace the existing label with the ECG label on the ECG module bracket. Fig. 7: Example of ECG label 2. Connect the ECG module to the ECG module bracket with the provided (4) screws. Fig. 8: Location of four screws on the ECG module bracket and the ECG module ACUSON X300 US11-100.892.01.05.02 09.11 Page 14 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade r3.0/4.0 3 3. Connect the ECG module to the inter-board. Fig. 9: ECG Module connection with Interboard 4. Place the DVD-R/RW and the ECG module bracket into the system. Refer to ( Install the CD/DVD-R/RW and ECG / US11-104.841.01). 5. Install the front, left and right covers on the system. Refer to ( System Cov‐ ers / US11-104.841.01). 6. Set the Main switch to On and power On the system. Wait for the system to fully boot-up. 7. Power Off the system and set the Main switch to Off. © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 15 of 30 Ultrasound ACUSON X300 15 16 3 Cardio-Vascular Option Upgrade r3.0/4.0 3.3 Verification 1. Power On the system and wait for the completion of boot-up. 2. Press Preset key to display the Preset screen 3. Select Service from the left menu pane. 4. Select Service. The Service Authentication screen displays. 5. Log onto the system service software using a customer level or SAL 7. Click OK. The Service Main Menu displays. 6. Select Configuration. 7. Select Hardware. 8. Scroll down the window and check if the replaced/installed boards are displayed with their part number, Serial number and Revision level correctly. Fig. 10: Hardware Details Window ACUSON X300 US11-100.892.01.05.02 09.11 Page 16 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade r5.0 and Above 4 4.1 Overview The section of this procedure describes the installation of the CV Option Field Upgrade for the ACUSON X300 PE r5.0 or higher systems. 4.1.1 Workflow 1. Install the RC-Daughter Board 2. Install the Advanced ECG Module 3. Install the Axius EF License 4. Verification 4.1.2 Requirements 4.1.2.1 Required Materials CV Option Field Upgrade, 10427822 4.1.2.2 Required Tools Standard tool kit 4.1.2.3 Required Time Upgrading the ACUSON X300 takes approximately one hour. 4.1.2.4 System Preparation Perform the EM module test (BIST) to ensure the system is fully operational before pro‐ ceeding to the upgrade procedure. 1. Power Off the system and set the Main switch to Off. Leave the power cord connec‐ ted to the wall outlet. WARNING The system contains hazardous voltages that can range from 90 VAC to 246 VAC and cause serous injury. Only authorized service personnel are permitted to remove protective covers and access the energized components of this system. © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 17 of 30 Ultrasound ACUSON X300 17 18 4 Cardio-Vascular Option Upgrade r5.0 and Above 2. Remove the right, left and rear covers. Refer to ( System Covers / US11-104.841.01). 4.1.3 RC-Daughter Board Installation 1. Move the system to a level location that provides one meter of work space around the system. 2. Disconnect the transducers from the system. 3. Remove the left, right, and rear covers. Refer to ( System Cov‐ ers / US11-104.841.01). 4. Remove the EM cover. 5. Remove the RC board. Refer to ( Remove the Boards / US11-104.841.01). 6. Carefully assemble the RC daughter to the removed RC board and fasten with (2) screws. Refer to ( Install the RC Daughter Board / US11-104.841.01). Fig. 11: RC Board with RC-Daughter Board 7. Place the RC board into the system. Refer to ( Install the E Module and Boards / US11-104.841.01). ACUSON X300 US11-100.892.01.05.02 09.11 Page 18 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade r5.0 and Above 4 4.2 Install the Advanced ECG Module The ECG Module is the same as the Physio Module. 1. Remove the CD/DVD-R/RW and the ECG module bracket from the system. Refer to ( Removing the CD/DVD-R/RW and ECG / US11-104.841.01). Replace the existing label with the ECG label on the ECG frame. Fig. 12: ECG Module Label 2. Place the Advanced ECG module on the removed ECG Module bracket. Fig. 13: ECG Module Bracket Shown with ECG © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 19 of 30 Ultrasound ACUSON X300 19 20 4 Cardio-Vascular Option Upgrade r5.0 and Above 3. Flip the ECG Module bracket over and install the (4) screws. Fig. 14: Location of (4) screws on the ECG Module Bracket 4. Connect the Physio Inner Cable to the ECG Module and the other end to the Interboard. Fig. 15: ECG Module Connection with Inter-board 5. Place the DVD-R/RW and the ECG Module bracket into the system. Refer to ( Install the CD/DVD-R/RW and ECG / US11-104.841.01). 6. Install the right, left, front and rear system covers. Refer to ( System Cov‐ ers / US11-104.841.01). ACUSON X300 US11-100.892.01.05.02 09.11 Page 20 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade r5.0 and Above 4 7. Set the Main switch to On and power On the system. Wait for the system to fully boot-up. 8. Power Off the system and set the Main switch to Off. © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 21 of 30 Ultrasound ACUSON X300 21 22 4 Cardio-Vascular Option Upgrade r5.0 and Above 4.3 Install Axius EF License 4.3.1 Refer to the user manual for instructions on how to properly install the optional license. Prepare the system for the license load This section describes the installation of the software-based optional license on the sys‐ tem using a CD/DVD drive. 1. Press Preset key to display the Preset screen. 2. Select Service from the left menu pane. 3. Select Service. The Service Authentication screen displays. 4. Log onto the syngo service software using a customer level or SAL 7. Click OK. The Service Main Menu displays. Fig. 16: Configuration Selection 5. Select Configuration. ACUSON X300 US11-100.892.01.05.02 09.11 Page 22 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade r5.0 and Above 4 6. Select License & Components on the left side of the screen. Fig. 17: License and Components Screen 7. Press the eject button on the CD/DVD drive on the left side of the ultrasound system to eject the CD/DVD tray. 8. Insert the License CD/DVD and press the Eject button again to load the CD/DVD. © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 23 of 30 Ultrasound ACUSON X300 23 24 4 Cardio-Vascular Option Upgrade r5.0 and Above 9. Click Select New License File tab to install the license software. Fig. 18: Select New License File 10. Select Install New License. The system displays a window containing the available software-based option license. 11. Select the software-based optional license to install. 12. Click Ok. The system installs the selected optional license. The selected optional li‐ cense is added to the list of installed licenses with the date of installation. ACUSON X300 Do NOT press any key during the license installation process. US11-100.892.01.05.02 09.11 Page 24 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade r5.0 and Above 4 13. Select Save. A license installation message is displayed. Fig. 19: License Installation 14. Press the eject button on the CD/DVD drive and remove the CD/DVD. 15. Select Home to exit the installation screen. This process will take a few minutes. Do NOT press any key during the process until prompted to reboot the system. © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 25 of 30 Ultrasound ACUSON X300 25 26 4 Cardio-Vascular Option Upgrade r5.0 and Above 16. When a reboot message appears, select Ok, to reboot the system. Fig. 20: Reboot Message 4.3.2 Verification 1. Power On the system and wait for the completion of boot-up. 2. Press Preset key to display the Preset screen 3. Select Service from the left menu pane. 4. Select Service. The Service Authentication screen displays. 5. Log onto the system service software using a customer level or SAL 7. Click OK. The Service Main Menu displays. 6. Select Configuration. 7. Select Hardware. ACUSON X300 US11-100.892.01.05.02 09.11 Page 26 of 30 Ultrasound © Siemens, 2011 Restricted Cardio-Vascular Option Upgrade r5.0 and Above 4 8. Scroll down the window and check if the replaced/installed boards are displayed with their part number, Serial number and Revision level correctly. Fig. 21: Hardware Details Window © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 27 of 30 Ultrasound ACUSON X300 27 28 5 Changes to Previous Version 5.1 Changes to Previous Version ACUSON X300 Change(s) Description Revision 05 Added “changes to previson version, and revised for document improvement project. Added sec‐ tion for 1.0/2.0 upgrade. Revision 03 and 04 Added text for r7.0. Revision 02 Added text for r6.0 New document Initials Release. US11-100.892.01.05.02 09.11 Page 28 of 30 Ultrasound © Siemens, 2011 Restricted List of Hazard IDs 6 There are no Hazard IDs in this document. © Siemens, 2011 Restricted US11-100.892.01.05.02 09.11 Page 29 of 30 Ultrasound ACUSON X300 29 - Restricted - All documents may only be used by authorized person‐ nel for rendering services on Sie‐ mens Healthcare Products. Any document in electronic form may be printed once. Copy and distribu‐ tion of electronic documents and hardcopies is prohibited. Offenders will be liable for damages. All other rights are reserved. healthcare.siemens.com/services Siemens Healthcare Headquarters Siemens Healthcare GmbH Henkestrasse 127 91052 Erlangen Germany Telephone: +49 9131 84-0 siemens.com/healthcare Print No.: US11-100.892.01.05.02 | Replaces: US11-100.892.01.04.02 Doc. Gen. Date: 09.11 | Language: English © Siemens Healthcare GmbH, 2011 siemens.com/healthcare
0
You can add this document to your study collection(s)
Sign in Available only to authorized usersYou can add this document to your saved list
Sign in Available only to authorized users(For complaints, use another form )