New floodlit tennis courts Existing Hotel patio Existing outdoor Pool New pool/cafe New summer house by existing outdoor pool Location of Pool/Cafe distribution board Up Footpath Existing hotel building New hotel extension Location of existing hotel CCU and distribution boards Draw in and label the route for the distribution circuit to the pool/cafe. A Up A New hotel extension west elevation Scale 1:100 B A A A Car Park A A A A A A A A A A A A A ground SITE PLAN SCALE 1:500 (Stated scales are correct when drawings are printed on A3 size.) Able Skills 2365 Drawings V-2 New café and basement pool south elevation Elevations scale 1:100 Proposed new hotel extension and café with basement swimming pool Site Plan and Elevations Drawing 1 of 5 Drawing Number 2365-AS1 Suite GF 01 Room GF 02 Service Cupboard Corridor Service Cupboard Scale 1:50 when printed at A3 Corridor 6. a) Show, on the drawing, positions of lighting, socket-outlets and fused connection units for the rooms in the new hotel block shown above, giving consideration to the following items of equipment in each room • kettle • TV • provision for phone charging and/or laptop use • supply to a 700 W air handling unit for heating/cooling (installed by specialist) • electric towel rail. b) Show, on the drawing, any further distribution boards that may be required in the hotel extension. c) Show on the drawing, how each circuit in the new hotel extension is to be arranged. (The arrangement must take into account that a fault in any one room must not effect another room.) Each circuit should originate at a distribution board. d) Give each circuit a unique form of identification, marked on the drawings e) Complete the legend below using recognised symbols and descriptions for each symbol used.. Additional Notes: Explain briefly your choices and the reasons for them. Able Skills 2365 Drawings V-2 Proposed new hotel extension and café with basement swimming pool Hotel Extension Ground Floor Plan Drawing 2 of 5 Drawing Number 2365-AS2 Up 2 Main pool Up 2 sauna Pool and pump equipment 2 Plunge pool FCU for hand dryer Male changing FCU for hand dryer Female changing 2 Scale 1:50 when printed at A3 Able Skills 2365 Drawings V-2 Proposed new hotel extension and café with basement swimming pool Swimming Pool Floor Plan Basement Drawing 3 of 5 Drawing Number 2365-AS3 2 2 Down 2 Food holding unit 2 Gas cooker 2 2 Servery counter 2 2 x Fridges 16 A Isolator for Food holding unit 16 A per phase 2 2 2 2 2 2 x Fridges 16 A Fridges Dishwasher 16 A 2 Down Fire Alarm panel 2 2 x2 vending machines 230 V 1.2 kW each New TP-N DB Zdb = 0.21 Ω 2 Scale 1:50 when printed at A3 Able Skills 2365 Drawings V-2 Proposed new hotel extension and café with basement swimming pool Café Floor Plan Ground Floor Drawing 4 of 5 Drawing Number 2365-AS4 2 symbol Legend (For ALL drawings) description symbol description 2 2 2 2 Summerhouse floor plan Scale 1:50 There is no express requirement to 'design' these circuits. Their loads are already accounted for in the 32A supply to the summer house, fed from the Cafe DB Summerhouse east elevation Scale 1:50 (at A3) Able Skills 2365 Drawings V-2 Proposed new hotel extension and café with basement swimming pool New poolside summerhouse Drawing 5 of 5 Drawing Number 2365-AS5