SAFETY PRECAUTIONS Supply Product Certification R LISTED 100 to 240V AC, -15% +12%, 50/60Hz, (±5%) MFM383A / MFM383A-C MFM383A-C-CE 100 to 240V AC, -15% +12%, 50/60Hz, (±5%) Installation Category III 96 x 96 SPECIFICATIONS DISPLAY Liquid crystal display with backlight 3 lines, 4 digits per line to show electrical Parameters Dedicated 7½ digit show energy WIRING INPUT 3 Ø - 4 wire, 3 Ø - 3 wire, 2 Ø - 3 wire and 1 Ø - 2 wire system RATED INPUT VOLTAGE 11 to 300V AC (L-N) ; 19 to 519V AC (L-L) ; Installation Category III (600V) UL Approval : RS485 and MODBUS RTU Communication address 1 to 255 Transmission mode Half duplex Data types Float and Integer Transmission distance 500m maximum Transmission Speed 300, 600,1200, 2400, 4800, 9600,19200 (in bps) Parity None, Odd, Even Stop bits 1 or 2 Voltage VL-N Accuracy ±0.5% of Full scale Voltage VL-L ±0.5% of Full scale Current ±0.5% of Full scale Frequency ±0.1% For L-N Voltage >20V, For L-L Voltage >35V Active Power 1% Reactive Power 1% Power Factor ±0.01 Active Energy Class 1 Reactive Energy Class 1 Apparent Energy Class 1 WARNING : 1. To prevent the risk of electric shock, power supply to the equipment must be kept OFF while doing the wiring arrangement. 2. Wiring shall be done strictly according to the terminal layout. Confirm that all connections are correct. 3. Use lugged terminals. 4. To reduce electromagnetic interference use of wires with adequate ratings and twists of the same in equal size shall be made with shortest connections. 5. Layout of connecting cables shall be away from any internal EMI source. 6. Cable used for connection to power source, must have a cross section of 0.5mm2 to 2.5mm2 ( 20 to 14AWG ; 750C (minimum)).Thesewires shall have current carrying capacity of 6A. 7. Copper cable should be used ( Stranded or Single core cable ). 8. Before attempting work on device, ensure absence of voltages using appropriate voltage detection device. INSTALLATION GUIDELINES 1% Apparent power 1. Read complete instructions prior to installation and operation of the unit. 2. Risk of electric shock. 3. The equipment in its installed state must not come in close proximity to any heating sources, oils, steam, caustic vapors or other unwanted process by products. OUTLINE Dimensions (in mm) WIRING GUIDELINES ACCURACY : Measurement CAUTION : RESOLUTION : PT Ratio x CT Ratio kWh Pulse <150 0.1K 0.1K 150 1K 1K NOTE : 1) For Voltage, Current and Power, resolution is automatically adjusted 2) For power factor, resolution is 0.001 CAUTION : 1. This equipment, being built-in-type, normally becomes a part of main control panel and in such case the terminals do not remain accessible to the end user after installation and internal wiring. 2. Conductors must not come in contact with the internal circuitry of the equipment or else it may lead to a safety hazard that may in turn endanger life or cause electrical shock to the operator. 3. Circuit breaker or mains switch must be installed between power source and supply terminals to facilitate power 'ON' or ‘OFF’ function. However this switch or breaker must be installed in a convenient position normally accessible to the operator. 4. Before disconnecting the secondary of the external current transformer from the equipment, make sure that the current transformer is short circuited to avoid risk of electrical shock and injury. 5. The equipment shall not be installed in environmental conditions other than those mentioned in this manual. 6. The equipment does not have a built-in-type fuse. Installation of external fuse of rating 275V AC / 0.5Amp for electrical circuitry / battery is highly recommended. PANEL CUTOUT Dimensions (in mm) 99 91.5 50 5 MAINTENANCE 1. The equipment should be cleaned regularly to avoid blockage of ventilating parts. 2. Clean the equipment with a clean dry or damp cloth. Do not use any cleaning agent other than water. TERMINAL CONNECTIONS MFM383A / MFM383A-C L + ENVIRONMENTAL CONDITIONS - Indoor use - Altitude of up to 2000 meters - Pollution degree II Temperature : Operating : -10 to 55OC Storage : -20 to 75OC Humidity : Up to 85% RH, non-condensing PROTECTION CLASS : II MOUNTING Panel mounting WEIGHT MFM383A : 310gms ; MFM383A-C : 344gms OUTPUT Pulse Output : Voltage range : External 24V DC max. Current capacity : 100mA max. Pulse Width : 100ms ±5ms. Interface standard and protocol For installing the meter 1. Prepare the panel cutout with proper dimensions as shown below. 2. Push the meter into the panel cutout. Secure the meter in its place by fitting the clamp on the rear side. Fit clamps on both sides in diagonally opposite location for optimum fitting. 3. For proper sealing, tighten the screws evenly with required torque. Terminal screw tightening torque : 0.68 N-m to 0.79 N-m ( 6.018 In-Lb to 6.992 In-Lb ) Screw clamp tightening torque : 0.1N-m (0.885 Lb-inch) + 11 to 277V AC (L-N) ; 19 to 480V AC (L-L) ; Installation Category III (300V L-N) FREQUENCY RANGE 45-65Hz RATED INPUT CURRENT Nominal 5A AC (Min-11mA, Max-6A) BURDEN 0.5 VA@5A per phase CT PRIMARY 1A / 5A to 10,000A(Programmable for any Value) Note : 1A to 10,000A if CT secondary is 1 else CT primary is 5A to 10,000A CT SECONDARY 1A or 5A (programmable) PT PRIMARY 100V to 10,000V (Programmable for any value) PT SECONDARY 100 to 500V AC (L-L)(Programmable for any value) DISPLAY UPDATE TIME 1sec. for all parameters DISPLAY SCROLLING Automatic or Manual (Programmable) POWER CONSUMPTION MFM383A / MFM383A-C : Less than 8VA SERIAL COMMUNICATION [ Applicable for MFM383A-C ] All safety related codifications, symbols and instructions that appear in this operating manual or on the equipment must be strictly followed to ensure the safety of the operating personnel as well as the instrument. If the equipment is not used in a manner specified by the manufacturer it might impair the protection provided by the equipment. Do not use the equipment if there is any mechanical damage. Ensure that the equipment is supplied with correct voltage. MECHANICAL INSTALLATION 91.5 ORDER CODE INFORMATION 90.5 OP623-V01 Operating Instructions 99 MFM383A SERIES N selec PULSE O/P RS485 Valid for communication model only CONNECTIONS DIAGRAM L1 L O L2 L3 A N D S1 S2 I1 S1 S2 I2 S1 S2 N V1 V2 V3 I3 Doc. name : OP INST MFM383A SERIES OP623-V01(Page 1 of 4) KEY PRESS Config page. ONLINE PAGE DESCRIPTION Press The 11th screen : (Page 19) Displays total “P” active power, reactive power and power factor of 3 phases. The 12th screen : (Page 20) Displays total active power, apparent power and power factor of 3 phases. There are 3 dedicated keys labelled as VI, VAF, P. Use these 3 keys to read meter parameters. Simply press these keys to read the parameters. Press The 1st screen : (Page 9) Displays power factor “P” of 3 phase. The 2nd screen : (Page 10) Displays active power of 3 phase. The 3rd screen : (Page 11) Displays reactive power of 3 phase. The 4th screen : (Page 12) Displays apparent power of 3 phase. The 5th screen : (Page 13) Displays active power, reactive power and power factor of 1st phase. The 6th screen : (Page 14) Displays active power, apparent power and power factor of 1st phase. The 7th screen : (Page 15) Displays active power, reactive power and power factor of 2nd phase. The 8th screen : (Page 16) Displays active power, apparent power and power factor of 2nd phase. The 9th screen : (Page 17) Displays active power, reactive power and power factor of 3rd phase. The 10th screen : (Page 18) Displays active power, apparent power and power factor of 3rd phase. Slave Id Active Network selection in configuration mode Wiring 1 to 255 1 3P4W 3P4W, 2P3W, 1P2W 9600 3P3W 3P3W Baud Rate *10 Parity None, Even, Odd None *11 Stop Bit 1 or 2 1 12 Back Light 0 to 7200 sec. 0000 13 Max Page 1 to 20 20 14 Change Sequence No / Yes No 14.01 Page Sequence 1 1 to 20 1 14.02 Page Sequence 2 1 to 20 2 14.03 Page Sequence 3 1 to 20 3 14.04 Page Sequence 4 1 to 20 4 14.05 Page Sequence 5 1 to 20 5 14.06 Page Sequence 6 1 to 20 6 14.07 Page Sequence 7 1 to 20 7 14.08 Page Sequence 8 1 to 20 8 14.09 Page Sequence 9 1 to 20 9 SERIAL NUMBER DESCRIPTION 14.10 Page Sequence 10 1 to 20 10 Press 4th key ( ) for 10sec. to display 8 digit serial number on first and second row. 14.11 Page Sequence 11 1 to 20 11 14.12 Page Sequence 12 1 to 20 12 Press The 1st screen : Displays active energy of “E” three phase. The 2nd screen : Displays reactive energy of three phase. The 3rd screen : Displays apparent energy of three phase. Note : 1) Only 1st screen will be displays of active energy when active select in configuration. 2) Energy parameter and Energy reading toggle automatically at the rate of 2 sec when select all in energy selection in configuration. AUTOMATIC / MANUAL MODE DESCRIPTION Press ( ) key 3 sec. to toggle between Automatic and Manual mode. Note : By default unit operates in automatic mode. In automatic mode online pages scroll automatically at the rate of 5 sec. per page. In automatic mode when any key is pressed, unit temporarily switches to manual mode and the appropriate page is displayed, also if any key is not pressed for 5sec., unit resumes automatic mode. * CONFIGURATION APPLICATION OF PULSE OUTPUT PROCESS INTEGRATION 24V DC maximum + P L C # Valid for communication model only + L + + PULSE O/P RS485 MFM383A / MFM383A-C I1 S1 I3 I2 S2 S1 S2 S1 S2 N V1 V2 V3 Pulse output from MFM383A meter can be interfaced into a process through a PLC for on line control of energy content in the process. If the PLC has a self excited digital input, external DC supply is not needed. The kWh pulse is also used to derive average kWh information at the PLC. Page Sequence 13 14.13 1 to 20 13 ENERGY CONTROLLER There are 4 dedicated keys with symbols marked as 12 / 24V DC Page Sequence 14 14.14 1 to 20 14 + , , , . Use these 4 keys to enter into To configuration menu / change setting. Page Sequence 15 14.15 1 to 20 15 Control Note : The settings should be done by a professional, Circuit + Page Sequence 16 14.16 1 to 20 16 after going through this users manual and after having # understood the application situation. Page Sequence 17 14.17 1 to 20 17 Valid for communication model only For the configuration setting mode : + ! Use ( ) and ( ) keys for 3sec. to enter or exit from Page Sequence 18 14.18 18 1 to 20 configuration menu. Page Sequence 19 + + 14.19 19 1 to 20 L Use ( ) and ( ) keys for increasing and decreasing PULSE RS485 O/P parameters value respectively. Page Sequence 20 14.20 1 to 20 20 ! Use ( ) key to go back to previous page. Use ( ) key to save the setting and move on next Factory Default No 15 No / Yes MFM383A / MFM383A-C page. O/P COUNTER I/P Press The 1st screen : (Page 4) Displays voltage, “VAF” current of 1st phase and frequency. The 2nd screen : (Page 5) Displays voltage, current of 2nd phase and frequency. The 3rd screen : (Page 6) Displays voltage, current of 3rd phase and frequency. The 4th screen : (Page 7) Displays average value of line to neutral voltage, current of three phases and frequency. The 5th screen : (Page 8) Displays average value line to line voltage, current and Power factor of three phases. Note : For 3 Ø 3 W system, only the 1st, 2nd, 3rd and 5th screen available. For 3 Ø - 4 W : Display Line to Neutral Voltage For 3 Ø - 3 W : Display Line to Line Voltage *8 Active / All 9 ONLINE PAGE DESCRIPTION Press The 1st screen : (Page 1) Displays line to neutral “VI” voltage of 3 phases. The 2nd screen : (Page 2) Displays line to line voltage of 3 phases. The 3rd screen : (Page 3) Displays phase current of 3 phases. Note : For 3 Ø 3 W system, only the 2nd and 3rd screen available Energy selection Factory Setting N KEY PRESS 7 NETWORK SELECTION AND WIRING INPUT Range or Selection 300, 600,1200, 2400, 4800, 9600 and19200 Note : For 3 Ø - 3 W system only the 11th and 12th screen available. ONLINE PAGE DESCRIPTION Function N FRONT PANEL DESCRIPTION Config page. Function Password Range or Selection Factory Setting 0000 to 9998 10 No / Yes No 1 Change Password 1.1 New Password 0000 to 9998 10 2 Network Selection 3P3W and 3P4W 3P4W 3 CT Secondary 1A or 5A 5 4 CT Primary 1A, 5A to 10,000A(10.0kA) 5 5 PT Secondary 100V to 500V 350 6 PT primary 100V to 10000V 350 16 Reset Energy 16.1 Password 16.2 Reset Active Energy No / Yes No 16.3 Reset Reactive Energy No / Yes No 16.4 Reset Apparent Energy No / Yes No No / Yes No 0001 to 9999 11 I1 S1 Marked parameters are available only in MFM383A-C. For resetting energy parameters user will be prompted for password. If correct password is entered, the user will be able to reset all energy parameters. This password will be value which will be greater than the configuration password by 1. I3 I2 S2 S1 S2 S1 S2 N V1 V2 V3 Pulse output from MFM383A meter can be used as alarm generator or total energy controller by interfacing it with Pre-settable counter and control circuits (Contactors, Relay, Trip Circuit). The counter is loaded with the maximum energy consumption. When count reaches setpoint it provides output to control circuit to take appropriate action. Note : + and - on aux. supply is applicable only for 24V product # All fuse types : 0.5A class CC UL type 0.5A fast acting 600V Doc. name : OP INST MFM383A SERIES OP623-V01(Page 2 of 4) MODBUS REGISTER ADDRESSES LIST Readable parameters from MFM383A-C : [ Length (Register) : 2 ; Data Structure : Float ] MODBUS register addresses list continued Address Hex Address Parameter Address Hex Address Parameter Readable / writable parameters from MFM383A-C : 30000 0x00 Voltage V1N 30034 0x22 kVA3 Address Hex Address 30002 0x02 Voltage V2N 30036 0x24 kVAr1 30004 0x04 Voltage V3N 30038 0x26 kVAr2 30006 0x06 Average Voltage LN 30040 0x28 kVAr3 30008 0x08 Voltage V12 30042 0x2A Total kW 40009 0x09 Range Parameter Parity Length (Register) Data Structure 1 Integer 1 Integer Value Meaning 0x0000 None 0x0001 Odd 0x0002 Even 0x0000 1 0x0001 2 1 Set to factory setting range 1 Integer 1 Integer 30010 0x0A Voltage V23 30044 0x2C Total kVA 30012 0x0C Voltage V31 30046 0x2E Total kVAr 30014 0x0E Average Voltage LL 30048 0x30 PF1 30016 0x10 Current I1 30050 0x32 PF2 40011 30018 0x12 Current I2 30052 0x34 PF3 40012 0x0C Reset kWh 1 Reset Total Active Energy 30020 0x14 Current I3 30054 0x36 Average PF 40013 0x0D Reset kVAh 1 Reset Total Apparent Energy 1 Integer 30022 0x16 Average Current 30056 0x38 Frequency 1 Reset Total Reactive Energy 1 Integer 30024 0x18 kW1 30058 0x3A kWh Min Value Max Value 30026 0x1A kW2 30060 0x3C kVAh 30028 0x1C kW3 30062 0x3E kVArh 1 20 1 Integer Page No Meaning 30030 0x1E kVA1 30032 0x20 kVA2 30064 0x40 40010 40014 40015 Serial Number (Data Structure : Hex) Readable / writable parameters : Address Hex Address 40000 40001 0x00 0x01 Range Parameter Password N/W selection Min value Max value 0 9998 Value Meaning Length Data (Register) Structure 0x0E 0x0F Factory Default Reset kVArh Auto Mode Pages 40016 0x10 Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40017 0x11 Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40018 0x12 Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40019 0x13 Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40020 0x14 Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40021 0x15 Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40022 0x16 Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 1- 20 1- First Page ; 20-Last Page 1 Integer Integer 40023 0x17 Page Address Sequence 40024 0x18 Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40025 0x19 Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 0x1A Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 0 3P-4W 1 1 3P-3W 1 Integer Max Value 0x0B Stop bit 1 Integer Min Value 0x0A 40002 0x02 CT Secondary 1 5 1 Integer 40026 40003 0x03 CT primary (CT Secondary = 5) 5 10000 1 Integer 40027 0x1B Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer CT primary (CT Secondary = 1) 1 10000 40028 0x1C Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40004 0x04 PT Secondary 100 500 1 Integer 40029 0x1D Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40005 0x05 PT primary 100 10000 2 Integer 40030 0x1E Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40007 0x07 Slave Id 1 255 1 Integer Value Meaning (bps) 0x0000 300 40008 0x08 Baud rate 1 Integer 40031 0x1F Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40032 0x20 Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 40033 0x21 Page Address Sequence 1- 20 1- First Page ; 20-Last Page 1 Integer 1- 20 1- First Page ; 20-Last Page 1 Integer 1- 20 1- First Page ; 20-Last Page 1 Integer 0x0001 600 40034 0x22 Page Address Sequence 0x0002 1200 40035 0x23 Page Address Sequence 0x0003 2400 0x0004 4800 0x0005 9600 0x0006 19200 40036 0x24 Backlight 40037 0x25 Energy Selection Min Value Max Value (Sec.) 0 (Always on) 7200 1 Integer 0 Active 1 Integer 1 All 1 Integer Doc. name : OP INST MFM383A SERIES OP623-V01(Page 3 of 4) TYPICAL WIRING DIAGRAM 3 PHASE 3-WIRE 3 Ø - 4 WIRE, 3 CT’S N + # + + PULSE O/P N L + RS485 I1 S1 S2 S1 S2 I1 N V1 V2 S1 V3 + RS485 S1 S2 S1 N V1 V2 V3 S1 L3 L2 L2 L1 L1 LOAD LINE 3 Ø - 3 WIRE, 2 CT’S and 2 PT’S N N N V1 S1 I3 I2 S2 S1 S2 S1 S2 N V1 V2 V3 # + + RS485 # All fuse types : 0.5A class CC UL type 0.5A fast acting 600V L # + + + PULSE O/P L L1 LOAD LINE 2 Ø - 3 WIRE, 2 CT’S and 2 PT’S + + PULSE O/P N L N L1 LOAD N # + RS485 V3 V2 LINE L + + PULSE O/P N L I1 S2 + RS485 L2 N L + PULSE O/P L N 3 Ø - 4 WIRE, 3 CT’S and 3 PT’S + S1 + MFM383A / MFM383A-C I3 I2 S1 S2 S2 + # N L3 LOAD # + RS485 # # LINE L # + + PULSE O/P L I1 S2 + MFM383A / MFM383A-C I3 I2 S2 N # + + PULSE O/P 1 Ø - 2 WIRE, 1 CT L MFM383A / MFM383A-C I3 I2 S2 + L MFM383A / MFM383A-C S1 N L N # 1 PHASE - 2 WIRE 2 Ø - 3 WIRE, 2 CT’S 3 Ø - 3 WIRE, 2 CT’S L N N 2 PHASE - 3 WIRE N 3 PHASE 4-WIRE (COMMONLY USED) CONNECTION DIAGRAM FOR COMMUNICATION + RS485 Master MFM383A / MFM383A-C I1 S1 S2 I1 I3 I2 S1 S2 MFM383A / MFM383A-C S1 S2 N V1 V2 S1 V3 I2 S2 S1 S2 MFM383A / MFM383A-C I3 S1 I1 S2 N V1 V2 V3 S1 # # S2 I2 S1 S2 I3 S1 S2 N V1 V2 V3 RS485-RS232 Converter Suggested terminating resistor (120 ohm, ¼ watt) # V V 1 2 LOAD A 2 3 2 3 PF 3 1 PF 3 1 Avg LINE 1 2 A 2 3 Avg kWh N V 1 2 A PF 3 1 Avg kWh kWh N A/M VI L3 L3 L2 L2 L2 L1 L1 L1 LINE LOAD LINE VAF P PRG E A/M VI VAF P PRG E A/M VI VAF P PRG E Contact sales for PC based monitoring software to communicate with the meters. LOAD (Specifications are subject to change, since development is a continuous process.) Selec Controls Pvt. Ltd., India Factory Address : EL-27/1, Electronic Zone, TTC Industrial Area, MIDC, Mahape, Navi Mumbai - 400 710, INDIA. Tel. No. : +91-22-41 418 419/430 | Fax No. : +91-22-28471733 Toll free : 1800 227 353 (BSNL/MTNL Subscribers only) Website : www.selec.com | Email : sales@selec.com Disclaimer : "This product is strictly for industrial use and for sale in non European countries only" Doc. name : OP INST MFM383A SERIES OP623-V01(Page 4 of 4)