GCB Type HEC 7S ABB Generator Circuit-Breaker System Solution for large power plants Data & Dimensions ABB voltage transformers, surge capacitors and surge arrester, • all integrated and mounted in the phase enclosures. Applications The HEC 7S generator circuit-breaker system has been developed as a system suitable for application in all types of power plants. Modular Design Concept The HEC 7S generator circuit-breaker is also suitable for retrofitting in existing power plants when these are modernized, extended and/or automated. The standard execution of the HEC 7S includes: • SF6 circuit-breaker and disconnector • earthing switches on one or both sides • current transformers on one or both sides with up to three cores • one or two voltage transformers on one or both sides with one or two secondary windings • surge arrester on disconnector side • surge capacitors on generator- and transformer side. The HEC 7S generator circuit-breaker system is available for indoor installation. Characteristics • Three-phase system with a SF6 circuit-breaker and disconnector in single-phase enclosures, supplied fully assembled on a common frame, with operating mechanisms, supervisory and control equipment • the phase distance can be selected to suit the busbar in the power plant • additional to the circuit-breaker and series disconnector, the generator circuit-breaker system is available with earthing switches, current and As required by the plant layout, individual components can be deleted from the standard execution. Equipment limits 12 11 9 10 19 18 18 T G 14 1 2 3, 4 9, 10, 11, 12 13, 14 15 16, 17 18 19 17 4 1 2 3 16 15 13 Circuit-breaker Disconnector Earthing switches Voltage transformers Current transformers Surge arrester Surge capacitors Terminals (limit of supply) System enclosure ABB 2 Technical Data General Rated maximum voltage: Rated frequency Rated continuous current Limiting conditions for rated continuous current • installation • ambient temperature • temperature of busbar conductor • temperature of busbar enclosure • return current in enclosure 30 kV, rms 50/60 Hz 23000/22000 A indoor 40 90 70 > 95 °C °C °C % * Service currents for other conditions on request Rated dielectric strength: Power frequency, 1min • to ground and across circuit-breaker/switch contacts • across isolating distance of disconnector • phase enclosure to ground Impulse, 1.2/50µs wave • to ground and across circuit-breaker/switch contacts • across isolating distance of disconnector Seismic acceleration withstand Degree of protection • control cubicle and mechanism • phase enclosure Installation, horizontal Circuit-breaker Peak withstand current Closing and latching capability Short-time current-carrying capability Rated short-circuit current System-source interrupting capability • symmetrical • degree of asymmetry • transient recovery voltage (TRV) rating Generator-source interrupting capability • symmetrical • degree of asymmetry • transient recovery voltage (TRV) rating Out-of-phase interrupting capability (180°) • symmetrical • degree of asymmetry • transient recovery voltage (TRV) rating Load current interrupting capability • symmetrical • degree of asymmetry • transient recovery voltage (TRV) rating Excitation current switching capability Interrupting time (till arc extinction) Opening time (till contact separation) Closing time (till contact touch) Service capability/maintenance 80 kV, rms 88 kV, rms 2 kV, rms IEC 61166 IEC 60529 IEC 60529 150 kV, peak 165 kV, peak Class AF5 with 5 % damping IP54 IP65 indoor IEEE Std C37.013 390 kA, peak 390 kA, peak 140 kA/3s 140 kA, rms 140 kA, rms 75 % 6.0 kV/µs 130 kA, rms 110 % 2.2 kV/µs 135 kA, rms 75 % 7.4 kV/µs 23000 A, rms 0 % 1.6 kV/µs 100 A, rms ≤ 56 ms 30 ± 3 ms 75 ± 15 ms ABB 3 Technical Data • short-circuit current interruptions, 140kA • rated current interruptions • no-load mechanical • elapsed time in service Rated duty cycles • short-circuit • load currents up to rated current • mechanical Control voltage Operating mechanism • type • pump motor, 220VDC or AC • number of stored operations SF6 gas • filling pressure at 20°C • leakage rate Noise level, 0.9 m distance Disconnector 5 150 10000 15 CO CO CO years CO-30min-CO CO-3min-CO CO-30sec-CO 110/220 or 125/250 VDC spring-hydraulic 1100 W 2 CO 620 kPa < 0.5 %/a < 127.6 dB, peak IEC 62271-102 Peak withstand current Short-time withstand current Operating time, close or open Operating mechanism: Service capability • no-load mechanical • elapsed time in service Earthing switch Peak withstand current Short-time withstand current Operating time, close or open Operating mechanism: Service capability • no-load mechanical • elapsed time in service Current transformer Type Primary current Secondary current Cores Output • IEC: protection metering • ANSI: protection metering motor, 3x400 V, 3-phase 390 140 2 1130 kA, peak kA/3s s W 10000 CO 15 years IEC 62271-102 motor, 3x400 V, 3-phase 390 140 2 1130 kA, peak kA/1s s W 5000 CO 15 years IEC 60044-1 toroidal-core up to 23000 A, rms 5 / 1 A, rms 1 to 3*** nos. 5P10 to 10P20 / 5A 5P10 to 10P20 / 1A 0.1 to 0.2 // 5 / 1A C400/C800 / 5A C400/C800 / 1A 0.3 / 5A max.. 200*** VA max. 100 VA max. 60 VA max. 100/200 VA max. 20/40 VA B-0.1 to B-1.8 *** depending on class and secondary current Voltage transformer IEC 60044-2 ABB 4 Technical Data Type Primary connection Primary voltage Secondary voltage Secondary connection Secondary windings Primary fuses Output • IEC: protection metering • ANSI: Surge arrester Type Rated discharge current, 8/20µs Impulse withstand current, 4/10µs Line discharge according • IEC 60099-4 • IEEE (ANSI) C62.11 Capacitor epoxy resin Y max. 30/√3 kV, rms as per request V, rms Y / open ∆ 1 or 2 nos. optional 3P or 6P 0.2 to 3.0 0.3 0.6 1.2 max. 450 VA max. 30 to 150 VA WX WX, WXY WX, WXY, WXYZ IEC 60099-4 POLIM-H 12...37 metal-oxide 20 kA 100 kA class 4 station class IEC 60358 Type Capacitance: • transformer side • generator side PCB free 260 nF 130 nF Weight Generator circuit-breaker system with maximum amount of equipment. (Note: the weight depends on the detailed design of the apparatus and may vary considerably) to follow kg ABB 5 Dimension drawings (Refer to Drawing No.: 1HC0025395 Rev.AA) Remark: In pursuance of our continuing improvement policy, technical data of equipment described in this publication is subject to change without notification. ABB ABB Switzerland Ltd. High Voltage Products Brown Boveri Strasse 5 CH.8050 Zurich/ Switzerland Phone: +41 58 588 34 24 E-mail: gcb_sales@ch.abb.com www.abb.com 1HC0015509/010/AA ABB 6