PRODUCTS GUIDE Gas Chromatograph Organic Elemental Analyzer J-SCIENCE LAB CO.,LTD Gas Chromatograph , TCD, FID,FPD,Non-Radioactive ECD ✔ GC7100 Series /GC7100TF Lab Features ● Improved productivity owing to multi-step heating and blower forced cooling mechanism equipped as standard ● Simultaneous loadable with TCD and FID notwithstanding compact general-purpose equipment ● More uniform distribution of oven temperatures owing to adoption of the slide type column oven bottom ● Loadable with non-radiation source type ECD not necessitating legal formalities ● Loadable with detectors of FID, TCD, NPD, FPD and Non-Radioactive ECD ● Usable for capillary column and wide bore column analyses after fitting the capillary column kit ● Usable for applications such as use of the gas sampler, liquid auto sampler and headspace sampler Specifications Column oven R. T.+10 to 400 ℃, Column capacity: 7.78 L, Heating rate: 0.1 to 99.9 ℃/min Cooling 9 min (300 ℃ to 50 ℃) Carrier gas Control with constant flow valve (or constant pressure valve) and pressure gauge Gross weight Approx. 40 kg Analysis column Packed column and capillary column Overall dimensions Approx.495 (w) X 550 (d) X 440 (h) mm Injection port Ghost less injection port Power requirement AC100 V +/- 10 %, 1.5 kVA Safety mechanism Overheat preventive function provided at required places Gas Chromatograph, TCD, FID, HN, EN, NPD, FPD (Capillary System) ✔ GC Labostage Lab This high-performance gas chromatograph is featured in adoption of an electronic control for control of carrier gas. This general-purpose equipment of compact size accepts loading of multiple detectors to meet diversified analysis environmental requirements. Superb in operability and maintainability, the gas chromatograph can be easily operated by operators widely ranging frombeginners to skilled operators. Features Specifications ● Analyses available widely ranging from capillary column to packed column analyses ● Multiple detectors loadable to meet diversified analysis ● environmental requirements Easy setting of conditions on GC or PC ● Non-radiation source type ECD (EN) with no legal formalities ● required loadable ● Detectors: FID, TCD, NPD, FPD and EN Column oven Room temp +10 to 400 ℃ Heating Rate 0.1 to 50 ℃/min Analysis column Packed column and capillary column Flow control 0 to 300 mL/min Dimension Approx. 550 (w) X 550 (d) X 430 (h) mm Weight 40 kg Power requirement AC100 V, 50/60 Hz, 1.5 kVA −1− Gas Chromatograph (Gas Sampling system) GAS5000 QA/QC Space saving Installation is enabled at narrow space as a result of integration of gas chromatograph with sampling system to minimize required complicated piping and wiring. The system chromatograph can also be installed separately as required, depending on allowed installation space or specifications of the analysis system. Higher operability D eve lope d w ith imp o rtan c e p lac ed o n imp ro ved o p e r a b ility a n d p r o d u ctiv ity , th e high-performance system chromatograph featured in superb durability and maintainability enables inexperienced operators to perform complicated analyses smoothly. Specifications GAS5000 System Main body with sampling unit Column capacity 7.78 L Detector FID, TC-W (2 Set of TCD), T-TCD (Thermistor type TCD) Carrier gas control Pressure valve Sampling System Auto Sampling Valve, 2 Set Dimension 570(w) X 500(d) X 420(h)mm Temperature Room Temp +10 to 300℃ Ghost less injection port Weight Sampling Auto, Manual Approx. 40 kg Power requirement AC100 V, 50/60 Hz, 1.5 kVA GAS1000 Series System Configuration QA/QC 1. All-in-one type Impurities measurement system in N2 and air Detector FID Sample introduction port 2 auto sampling valve Operation Manual/ Auto by sequencer Measuring components CO, CH4 and CH4, C2H2, C2H4, C2H6, C3H8 Others Anti-inflammation detector, Methane converter Impurities measurement system in H2 and CO Detector TCD-W (2 X TCD) Sample introduction port 4 manual sampling valves Operation Manual Measuring components H2, O2, N2, CO2 Others Pre-amplifier, Reading sample flow path (displays on PC) CO/CH4 /CO2 measurement system in medical gas and Ar, N2 Detector T-TCD (thermistor-type), FID Sample introduction port 2 manual sampling valves Operation Manual sample Medical gas, O2, N2 Measuring components Medical gas (N2 in O2 or O2 in N2, etc.), CO, CH4, CO2 Others Methane converter −2− GAS1000 Series System Configuration Cont’d QA/QC N2O, CH4 and CO2 measurement system in the atmosphere Detector HPID, FID Sample introduction port Manual sampling valves Operation Manual Measuring components N2O, CH4, CO2 Others Methane converter Mixing air measurement system in welding nozzle Detector TF (TCD, FID) Sample introduction port 2 manual sampling valves Operation Manual/ Auto Measuring components O2, N2, CO2 Others Pre-amplifier, Methane converter, Welding nozzle jet plate Features ● Space-saving design of integration for GC and sampling unit. Available for separate type in accordance with special measurement system. ● It is a small-size of instrument though, wide range of components analysis is achievable by utilizing simultaneous installation of 2 detectors, such as TCD and FID, etc. ● As it is a small-exclusive instrument with high consideration for operation and functionality, wide range of system configuration which satisfies respective analysis needs can be achievable. Even an untrained operator can comply with complicated analysis comfortably. ● High accurate measurement is achievable as in the same as conventional-type instrument. A wide variety of sample measurement from trace to composition analysis can be attainable. ● In sequencer type, solo auto-operation is achievable and be utilized as wide range of data processing system. ● In continuous analysis system, daily/monthly reports will be produced by automatic transferring the quantitative results after every analysis completion, in combination with JC2000 (PC-type data processing device). 2. Separate type Impurities Measurement System in H2 Detector TF (TCD, FID) Sample introduction port 2 auto-sampling valves and 2 auto-precut valves Operation Manual/ Auto Measuring components O2, N2, CO, CH4, CO2, THC Others Methane converter, Anti-inflammation detector Total Sulfur Measurement System in H2 Detector FPD Sample introduction port 1 Auto-sampling valve and 1 Auto-precut valve Operation Manual/ Auto Measuring components Total Sulfur Others Concentrating function and Reduction function − 3− Impurities Measurement System in respective pure gas Detector FID-W (FID x 2) Sample introduction port 2 manual sampling valves, 2 auto-sampling valves, 2 Auto-precut valves Operation Manual/ Auto Measuring components N2, Ar, He, O2, Air Others Methane converter, Sample flow path reading device Impurities in ppb level measurement System in H2 He Detector TF (TCD, FID) Sample introduction port 1 auto-sampling valve and 1 auto-precut valve Operation Manual/ Auto Measuring components O2, N2, CO, CH4, CO2 Others Pre-Amplifier, Methane converter (with concentration function) System 2 : N2 in O2 Impurities Measurement System In pure gas Detector Sample introduction port 1 Auto-sampling valve and 1 auto precut valve System 1: H2, THC, CO, CO2, in O2 or N2 Detector TCD TF (TCD, FID) Operation Manual/ Auto Measuring components O2, N2, CO, CH4, CO2 Others Pre-Amplifier, D/A converter, Sample flow path reading device System 3: THC, C2H2 in O2/O2 mixture gas Sample introduction port 3 Auto-sampling valves Detector Operation Manual/ Auto Sample Argon gas Measuring components H2, CO, CO2, THC Others Methane converter, D/A converter (co-use with System 3), Anti-inflammation detector, Sample flow path reading device FID Sample introduction port 1 Auto-sampling valve Operation Manual/ Auto Measuring components THC, C2H2 Others Anti-inflammation detector, Sample flow path reading device ■ Data processing device Data processing device Data processing device JC2000 (PC type) µ7 (PC type) Methane converter unit Windows10 64 bit Methane converter unit Windows10 64 bit Measurement Area/Height, Half-value width,Conventional theoretical plates, etc. Measurement Area/Height, Half-value width,Conventional theoretical plates, etc. Input channel 2 ch (4 ch as option) Input channel 2 ch(4 ch as option) Input range -20 mV to 1 V Input range -2.5 V to +2.5 V Processing peak number Max. 320 peaks Processing peak number max. 1000 peaks Option accessory Flame detection device GFA-201 Data Processing Device JSμ7 (PC type) D/A Converter DAC-201 series Air Filtration Device APF-201 TCD Pre-Amplifier GPA-201 Channel Selector CHS-201, for 2ch exchange CHS-202, for 4ch exchange − 4− Automatic Fuel Gas Analyzer GC-2011 QA/QC All kinds of fuel gases can be automatically analyzed with high accuracy. Analysis available of 18 components ranging from H2 to C6 up; H2, O2, N2, CH4, CO, CO2, C2H4, C2H6, C3H4, Analysis of H2 to C5 available in 15 min only; Analysis time shortened with 3 pieces of TCD detectors and original column system. Automatic analysis without troublesome manual operations required; Automatic execution of analysis up to printout of a report simply with analysis started with sample gas flow. Specifications Column oven Fixed at 50 ℃ Detector TCD X 3 set Gross weight Approx. 60 kg (Main body only) Overall dimensions Approx. 580(w) x540(d) x430(h)(mm) Power requirement AC100 V +/- 10 %, 1.2 kVA Hydrogen in Steel Measuring System ✔ JTF-20A Lab QA/QC This system measures hydrogen in steel, the causative agent of delayed fracture,according to the thermal desorption method in use of the gas chromatograph. The system takes continuous batch measurements of hydrogen, verifies behavior of hydrogen to be discharged with temperature change, and displays data such as the temperature-amount of discharged hydrogen in a measurement result list and in a graph to t hereby verify behavior of hydrogen. Features ● Trace hydrogen component measurable with the gas chromatograph. Optional setting available of sample temperature programming rate and temperature range. ● Data of “Temperature-Hydrogen evolution rate” displayed graphically and in a list. ● Tubular furnace of opening and closing type featured in simple operations. ● Perfect safety measures established due to adoption of over-temperature protection system. ● Components other than hydrogen measurable as well (optional). Diffusible Hydrogen Analyzer ✔ GC206 Analyzer of diffusible hydrogen Specifications Gas chromatograph GAS1000T Detector TCD (with preamplifier) Auto gas sampler GAS-300 series product Tubular furnace GTF20A series product Data processing unit With calculation software Gross weight Approx. 180 kg Overall dimensions Approx. 1200(w) x1000(d) x1500(h)mm (excluded computer) Power requirement AC100 V +/- 10 %, 3.0 kVA Pyrolysis and hydrogen Addition unit Methane converter GPY-201 CH4-203 High polymar pyrolysis GC And hydrogen addition unit −5− High sensitivity measurement of CO, CO2 etc., through methane converter Oil in Liquid CO2 measuring System ✔ GAL202 QA/QC As to carbon dioxide as a food additive, oil (high-boiling point lubricating oil and others) is the object of measurement as well as inorganic gas components such as H 2 , O 2 , N 2 , sulfur compounds and hydrocarbon components. Out of them, oil had been conventionally measured according to the IR method after absorption in carbon tetrachloride. However, carbon tetrachloride could not be used as a result of enforcement of control of CFC. It was thus the problem with the IR method that long time is inevitable including pretreatment. This system performs full automatic operations of all processes, ranging from sample enrichment to FID measurement in adoption of the gas chromatograph method. Features This system is an item with utility model acquired (expiration of validity) featured in unique method of measurement not seen with products of other companies. As a result of establishment of full automatic operations, drastic labor saving and cost reduction have been attained as well as considerable improvement productivity in quality management activities. Gas chromatograph GC7100FID with temperature programming function Detector FID Auto heat-reserving gas sampler With enrichment mechanism Data processing unit With calculation software Gross weight Approx. 120 kg Overall dimensions Approx. 1500(w)x 800(d)x 600(h) mm Power requirement AC100 V +/- 10 %, 4.0 kVA Automatic GC Series AG-2 Series QA/QC Features ● With simultaneous fitting of max. 3 units of detectors and 4 lines of column systems, these gas chromatographs enable analysis of all components of diversified sample gases mixed with inorganic gas and organic substance. ● Microanalysis available from ppb level to sub ppm level. ● These gas chromatographs can be used for analysis of wet state gas containing much moisture. Specifications Measuring component H2 O2, N2 CH4, CO CO2 C2H4,C2H6,C3H6, C3H8,i&n-C4H10 Detector TCD1 TCD2 FID FID FID Carrier gas Ar (N2) He He He He General purpose 2 ppm 2 ppm 0.05 ppm 0.05 ppm 0.05 ppm High speed 20 ppm 20 ppm 0.5 ppm 0.5 ppm 0.5 ppm Min. detection sensitivity Trace Gas Analyzer Trace Nitrogen Analyzer Compact Trace Nitrogen Analyzer TGA-201 PES-1200 PES-050 ppb-level CO, CH 4 and CO 2 measurement with simple enrichment mechanism. This trace nitrogen analyzer is intended for measuring continuously the concentration of a trace of nitrogen gas contained in high-purity argon gas, which is detected by an emission spectrometric method. Measuring range 0 to 5, 0 to 10 ppm −6− This trace nitrogen analyzer, not requiring pretreatment, can have a direct sample introduction to monitor continuously the concentration of nitrogen, impurity in argon. It is not required carrier gas for such as gas chromatography, and saves a running costs. Measuring range 0.5 ppm to 50 ppm Offensive Odor Sample automatic measuring system ✔ GBA-201 Lab Features ● Comply with the Offensive Odor Control Law. ● Sample is an automatic concentration by cold trap method with liquid oxygen or liquid argon. ● The sample is introduced into Gas Chromatograph. Specifications Sample Introduction Auto 6-way sampling valve Flow path switching 3-way Solenoid valve Switching flow path Auto 4-way switching valve Valve control Pneumatic Concentration glass tube 4 mmφ x 300 mm, Heater Operation Auto/ Manual, Setting up by touch panel Mass flow meter Sample gas flow, Accumulated amount (max. 200 mL/min.) Sequence Sequence controller Constant flow valve Purge gas Overall dimensions Approx. 400(w)×460(d)×430(h) + 200(w)×300(d)×470(h)mm Suction pump Diaphragm pump Power requirement AC100 V 1.5 kVA Measurement component Sampling device Auto-concentration device Introduction device Measurement Ammonia Boric acid solution collection GBO-101A n/a n/a UV Sulfur compound Direct sampling - GBO-101A Suction case - GBO-101A GBA-201 GBA-201 GC (FPD) trimethylamine Collection by Sulfuric acid solution GBO-101A GBA-201 GBA-201 GC (FID) aldehyde genera Sampling bag GBO-101A GBA-201 cationic resin micro syringe GC (NPD) organic solvent Direct sampling - GBO-101A Suction case - GBO-101A GBA-201 GBA-201 GC (FID) lower fatty acid Collection by alkali beads GBO-101A n/a GBO-501 GC (FID) Offensive Odor Sample Pretreatment Device Sampling device GBO-101A, GBO-201A ■ Collection of ammonia and trimethylamine (TMA) GBP-101A Lab Gas Sampling device GBP-101A with accessory Dimension: 145(w) x 310)d) x 370(h)mm Weight: 14 kg Power requirement: AC100/200 V or DC12 V Integrating flowmeter Option Gas Sampling device GBO-101A with accessory Dimension: 145(w) x 310)d) x 370(h)mm Weight: 14 kg Power requirement: AC100/200 V or DC12 V Gas Sampling device GBO-101A with accessory Dimension: 145(w) x 310)d) x 370(h)mm Weight: 14 kg Power requirement: AC100/200 V or DC12 V Integrating flowmeter GBO-201A Gas Sampling device GBO-101A with accessory Dimension: 145(w) x 310)d) x 370(h)mm Weight: 14 kg Power requirement: AC100/200 V or DC12 V Integrating flowmeter Option Option ■ Direct collection using sampling bag. Sulfur compound, Aldehyde genera and Organic solvent ■ Collection of sulfur compounds and organic solvents using suction case GBO-101A GBO-201A GBO-101A ■ Collection of lower fatty acid using alkali beads GBP-101A Option −7− LPG Analyzer GC205 QA/QC LPG (liquefied petroleum gas) consists of a liquid phase portion and a gas phase portion. LPG is measured with the gas chromatograph with its liquid phase portion sampled and evaporated. ✔ Features With a liquid sample vaporizer attached, the analyzer enables analysis of the liquid phase portion through simple operations. Specifications Gas Chromatograph GAS 1000T Gross weight Approx. 50 kg Manual gas sampler GSL-800M series Overall dimensions Approx. 1200(w) x800(d) x600(h)mm Liquid sampling unit LSV-202 Power requirement AC100 V +/- 10 %, 1.25 kVA Data processing unit JSμ7 (PC type) EOG Densitometer ✔ GC216 QA/QC Accurate measuring of ethylene oxide concentration and relative humidity in the sterilization chamber. Specifications Measuring range 0 to 30 vol% Surrounding temperature 10 to 40 ℃ Temp. variation should be less than +/- 3 % Repeatability Less than +/- 5 %FS Recorder output DC 0 to 1 V Stability Both zero and span less than +/- 5 %FS Power source AC100 V +/- 10%, 50/60 Hz 1.0 kVA Response speed Within 1 min. (90 % response) Dimensions 392 (w) x318 (d) x199 (h)mm Sampling volume Less than 1 L/min. Weight Approx. 10 kg Warming up Within 180 min. Measuring method T-TCD Medical Gas Analyzer ✔ GC202A / GC202 QA/QC Features The analyzer enables analysis of the medical gas portion through simple operations. Specifications Column oven Temp. 50 ℃ Sample Medical oxygen and Medical nitrogen Detector Thermistor type TCD Measuring object Nitrogen and Oxygen Analysis column MS-5A, 3 m Range (Min. detection sensitivity 0.05 % Sample introduction Manual 8-way sampling valve (GC202) Automatic 8-way sampling valve(GC202A) Operations Manual (GC202), and automatic (GC202A)* Gross weight Approx. 20 kg Repeatability +/- 2 % Gas chromatograph GC202/ GC202A Components Data processor Air compressor Overall dimensions Approx. 450(w)x505(d)x225(h)mm (GC202A) Power requirement AC100 V +/- 10 % 300 VA −8− JSμ7 (PC type) For valve drive (GC202A) MICRO CORDER The Micro Corder JM11 is an organic trace element analysis system based on the Pregl-Dumas method to simultaneously determine 3 elements of carbon, hydrogen and nitrogen through computer control. Compared with conventional models, skillful analytical technique is no more required. Superb accuracy of analysis is obtained with simple operations of direct weighing of a sample onto the boat and its introduction into the combustion unit only. As a result of introduction of the most advanced technology of electronics, stability, operability and economization of the analyzer have been drastically improved. Micro Corder (Analyzer to Determine Carbon, Hydrogen and Nitrogen Simultaneously) JM11 Application ◆ Analysis for quality control of medicine and chemical industrial products ◆ Analysis of fuels such as oil, kerosene, fuel oil, coal and coke ◆ Analysis of soils, sludge, sewage treatment excess mud, etc. ◆ Analysis of atmospheric pollutants in vehicle exhaust emissions such as particulates, and analysis of organic carbon and inorganic carbon ◆ Analysis of raw materials and products of food JM11 S-Book Specifications Measuring element Carbon, Hydrogen, Nitrogen Option(Sulfur,Oxygen) Warm up time Autosampler Analyzing start-up possible in 90 minutes after power on Measuring method Self- integration (using dual piston pump) Carrier gas Helium (99.99 %up) Measuring accuracy Absolute error within ±0.3 % Combustion gas High purity Oxygen (99.99 %up) Hydrogen 1 to 400 μg Carbon 3 to 2600 μg Nitrogen 1 to 1000 μg (The above value is in case of standard analysis condition. There is possibility of extending upper/lower limit of range by varying the analysis condition.) Combustion method Helium and Oxygen mixing method Standard temperature setting CHN analysis Sample furnace 1000 ℃ Combustion furnace 800 ℃ Reduction furnace 600 ℃ Temperature setting from CPU 11 minutes JM11 Dimensions, weight 600(w) x 600(d) x 500(h)mm , 75 kg Measuring range Analysis time JMA-11, Autosampler Dimensions, weight 400(w)x600(d)x500(h)mm , 45 kg Sample weigh 2~10 mg, Approximately 2 mg of sample weighed by micro-balance. (capable of analyzing other samples than organic substance, such as soil, catalyst, etc. In these cases, maximum weight of sample is 1 g, ultra-micro analysis can be achieved by using ultra-micro balance) MACRO CORDER Carbon and Nitrogen Simultaneous Determination Unit JM1000CN TOC-TN Application ◆ Agriculture: Analysis of carbon and nitrogen in soils and crops. ◆ Livestock: Analysis of crude protein in raw materials and mixed fertilizers. ◆ Analysis of carbon and nitrogen in fertilizers. ◆ Food: Analysis for quality control of raw materials and products. Fuel: Analysis of fuels such as oil and coal. ◆ Chemical industry: Analysis of high molecular compounds, dyestuff, petrochemicals, etc. Environment: analysis of carbon and nitrogen in sludge and earth and sand on river bottom and sea bed; analysis of carbon, nitrogen in industrial waste Pharmaceutical and clinical analyses. Specifications Measuring element Carbon, Nitrogen Measuring method Self-integration method (Piston pump is used) Analysis time 9 to 10 minutes Measuring accuracy Absolute error +/- 0.3 % max. Sample weight Organic matter Max. 500 mg, Inorganic max 1 g Measuring range Carbon 0.2 to 125 mg Nitrogen 0.02 to 12 mg (The measuring range is for the case of analysis on standard conditions. The range can be extended through change of analysis conditions.) Detector Thermal Conductivity Detector Tungsten filament 60 Ω, 4 channel Detector oven 100 ℃ Pump oven 55 ℃ Power requirement AC100 V +/-10 % 50/60 Hz, 4 kVA JM1000 Dimensions, weight 760(w)x585(d)x485(h)mm,90 kg JMA-1000, Autosampler Dimensions, weight 900(w)x590(d)x470(h)mm,40 kg −9− Plasma Asher JPA301 ● This device can ash samples using oxygen plasma. ● The feature of this device is that it can ash various samples at lower temperature than the electric furnace. ● The ashing losses are minimal when using plasma ashing for pretreatment of asbestos or volatile samples. ● This device conforms to *JIS K 3850-1. *Determination of airborne fibrous particles -Part 1 : Optical microscopy method and scanning electron microscopy method Applicable to Refracted Ceramic Fiber standard measurement method (PCM method) (Ministry of Health, Labor and Welfare) ● The function of auto tuning against load fluctuation in the reaction chamber prevents the loss of plasma. ● Automatic ashing program operation controls from start to release to the atmosphere. ● We offer 2 or 3 shelves for processing multiple samples. Application Specifications ◆ Pre-treatment of asbestos ◆ Ashing of high concentration organic matter ◆ Simultaneous ashing of multiple specimens ◆ Surface treatment / surface modification treatment ◆ Etching of electronic parts ◆ Ashing of biological samples Frequency 13.56 MHz Chamber size Cylindrical I.D. 153, O.D 160,L:315 mm Output 30 to 300 watts Processing gas Oxygen Purge gas Indoor air Dimansions 420(w)×570(d)×H465(h) mm Weight Approx. 40 kg Power supply AC 100 V 50/60 Hz 1.5 kVA (included Vacuum pump) High-purity Hydrogen Generator RHG-200/300/500/700/1000 Features The high-purity hydrogen generator is designed to generate, through electrolysis of water, hydrogen to be used by the gas chromatographs equipped with a flame ionization detector (FID) or flame photometric detector (FPD), as well as by hydrocarbon analyzers. Specifications Type RHG-200 Purity Flow Meter OUT with Tank RHG-300 RHG-500 RHG-700 RHG-1000 H2 99.999 %up, 250 kPa(The value does not include moisture) 100 mL/min 300 mL/min 500 mL/min 700 mL/min 1,000 mL/min 2L 5L 10 L 10 L 10 L Pure Water Ion Exchange Water, less than 1μ S Power Requation AC100 V (other voltages available), 50/60 Hz Dimansions (mm) 130(w)×400(d)×250(h) 140(w)×400(d)×370(h) 250(w)×400(d)×380(h) 280(w)×640(d)×520(h) 280(w)×640(d)×520(h) Weight 11 kg 14 kg 20 kg Warming-up Time Approx. 5 min. − 10 − 25 kg 26 kg For the Customer J-SCIENCE LAB CO.,LTD Address : 3-1, Hiuchigata-cho, Kamitoba,Minami-ku, Kyoto 601-8144 JAPAN Phone : +81 (0)75 693 9480 Fax : +81 (0)75 694 9490 URL : http://www.j-sl.com Inquiry : mailbox@j-sl.com Company profile J- SCIENCE LAB was established in May 30, 2001 by mature engineers of Gas Chromatography and Organic Elemental analysis.We have been launching various unique products since 2001. And also we can propose various System-GC to meet the individual requirement.We shall continue strive to develop new analysis devices by making full use of advanced technology, to contribute to science technology and the society. Ver.1.1