Technical Publications Data Remove and Install Uninterruptable Power Supply UPS (UB20.241) 1G-G-LA-07-79-00A-040A-01 Information Issue Number: .............................................................................................................................. 01 Issue Date: ..................................................................................................................... 12/07/2019 Originator: ................................................................................................................................... PR Verified By: ................................................................................................................................. MS Verified Date: ................................................................................................................. 12/07/2019 Service Level:................................................................................................................. Technician Table of contents 1 2 3 3.1 3.2 Page Introduction .................................................................................................................... 3 Warnings and Safety Notices ....................................................................................... 3 Removal / Installation of the Uninterruptable Power Supply Unit (UB20.241) ........ 4 Removal of the Uninterruptable Power Supply Unit ........................................................ 5 Installation of the Uninterruptable Power Supply Unit ..................................................... 5 List of figures Figure 1. Applicable to: All Uninterruptable Power Supply Unit (UB10.245)..................................................... 4 1G-G-LA-07-79-00A-040A-01 Page 1 Technical Publications Data Details of Change Issue 01 Reason First Issue Date Signature 15/10/2018 L. Parker NOTICE: THIS DATA MODULE MUST BE READ IN CONJUNCTION WITH THE EDM SAFETY SECTION SUPPLIED. Applicable to: All 1G-G-LA-07-79-00A-040A-01 Page 2 Technical Publications Data 1 Introduction During routine maintenance, fault finding and repair, it may be necessary to remove / replace various electrical components from within the power and control cabinet. This document describes the procedure for removing and installing the Uninterruptable Power Supply UPS. 2 Warnings and Safety Notices WARNING ISOLATE POWER TO THE TRAINER AND DRIVE SYSTEM BEFORE ATTEMPTING TO CARRY OUT ANY MAINTENANCE TASKS. WARNING ALWAYS MAKE SURE CORRECT PERSONAL PROTECTION IS WORN. WARNING THIS LEVEL OF MAINTENANCE SHOULD ONLY EVER BE PERFORMED BY SUITABLY QUALIFIED ENGINEER. DANGER CHECK TIME SETTING ON UPS. WAIT ALLOTTED TIME TO ALLOW RESIDUAL POWER TO DRAIN FROM THE UPS BEFORE ATTEMPTING TO REMOVE ELECTRICAL EQUIPMENT. CAUTION ELECTROSTATIC SENSITIVE DEVICES MAY BE USED IN THIS EQUIPMENT WHICH COULD BE DAMAGED BY INCORRECT HANDLING. ALWAYS TAKE APPROPRIATE PRECAUTIONS WHEN HANDLING AND USE ELECTROSTATIC PACKAGING FOR STORAGE IF REMOVED. Applicable to: All 1G-G-LA-07-79-00A-040A-01 Page 3 Technical Publications Data 3 Removal / Installation of the Uninterruptable Power Supply Unit (UB20.241) When removing the UB20.241 uninterruptable power supply UPS unit the following procedure should be used. DANGER THIS PROCEDURE SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED ENGINEER. CORRECT PPE MUST BE WORN. NOTICE PLEASE REFER TO ELECTRICAL DRAWING SET SUPPLIED 4 2 3 4 5 1 1. Cable Connector & Socket 2. Cables 3. Securing Tabs 4. Buffer-time Limiter Screw 5. End-of-charge Voltage Screw Note: Cable Colours / Connections May Vary. Figure 1. Uninterruptable Power Supply Unit (UB20.241) Applicable to: All 1G-G-LA-07-79-00A-040A-01 Page 4 Technical Publications Data 3.1 Removal of the Uninterruptable Power Supply Unit 1. Isolate power to the device. 2. Turn the mains isolator to the OFF position. 3. Open the door of the power and control cabinet. DANGER CHECK TIME SETTING ON UPS. WAIT ALLOTTED TIME TO ALLOW RESIDUAL POWER TO DRAIN FROM THE UPS BEFORE ATTEMPTING TO REMOVE ELECTRICAL EQUIPMENT. 4. Locate the UPS. 5. Disconnect the cables from the bottom of the UPS by unplugging the connector (1) from its socket. 6. At upper front of UPS, note position of all cables (2). 7. At upper front of UPS, lift cable securing tabs (3) to open position. 8. Remove all cables (2). 9. Locate the din rail securing catch at the rear of the UPS. 10. Insert a flat bladed screwdriver into the catch and manipulate to release the catch. 11. Grasp the UPS, lift from din rail and remove from power and control cabinet. 12. Note the ‘Buffer-time Limiter’ (4) and ‘End-of-charge-Voltage’ (5) screw settings on the front of the UPS. 3.2 Installation of the Uninterruptable Power Supply Unit 1. Ensure mains power is OFF. 2. Place the new UPS onto the din rail. Press firmly till the UPS locks into position with the securing catch. 3. At lower position, push connector (1) into its socket. 4. At upper position, insert cables (2) in correct position, and close tabs (3). 5. Check that the ‘Buffer-time Limiter’ (4) and ‘End-of-charge-Voltage’ (5) screw settings are set to the same positions as those from the removed UPS unit. 6. Close the door to the power and control cabinet. 7. Turn ON power to the device. 8. Turn the mains isolator to the ON position. Applicable to: All 1G-G-LA-07-79-00A-040A-01 Page 5 Technical Publications Data END OF DATA MODULE Applicable to: All 1G-G-LA-07-79-00A-040A-01 Page 6