CVC Blood Draw (INTRO STEPS) Knock Introduce self to pt. 2 Patient Identifiers (Name, DOB) Verify allergies Perform hand hygiene Provide Privacy Inform pt on what you’re about to do. 1. PUT ON GLOVES. 2. PRIME HEPLOCK WITH 10CC SYRINGE. 3. MAKE SURE LINE IS CLAMPED, THEN TAKE OFF GREEN ALCOHOL CAP. 4. CLEAN LINE WITH ALCOHOL WIPE FOR 30 SECONDS. 5. ATTACH THE OTHER 10CC SYRINGE TO LINE. 6. UNCLAMP LINE. 7. FLUSH LINE WITH 10CC SYRINE. (USE PULSE METHOD) 8. PULL BACK 10CC INTO THE SYRINGE. (USE PULSE METHOD) 9. CLAMP LINE. 10. REMOVE SYRINGE WITH 10CC OF FLUID, VERBALIZE THAT YOU WOULD WASTE THAT. 11. ATTACH THE VACCUTAINER. 12. UNCLAMP LINE. 13. DRAW YOUR LABS. (ORDER: WHITE, BLUE, RED, GREEN, PURPLE, GREY) 14. CLAMP LINE. 15. REMOVE THE VACCUTAINER. 16. REMOVE USED HEPLOCK. 17. CLEAN LINE AGAIN WITH ALCOHOL WIPE FOR 30 SECONDS. 18. ATTACH NEW HEPLOCK. 19. UNCLAMP LINE. 20. FLUSH WITH ATTACHED 10CC SYRINGE. (USE PULSE METHOD) 21. CLAMP LINE. 22. REMOVE SYRINGE AND PLACE NEW GREEN ALCOHOL CAP ON LINE. SUPPLIES NEEDED: • • • • • • 10CC SYRINGE (2) ALCOHOL WIPES (2) HEPLOCK GREEN ALCOHOL CAP LAB TUBES VACCUTAINER