V32-EQ00 1 TM N/U 2 N/U 3 7 4 GRN TIP ALARM RELAY TAMPER OUTPUT N.O.COM N.C. COM N.C. keyswitch T-1 RED 2-wire smoke Cold water pipe grounding BLK Power supply or MR3-UL Relay WHT COM GRN Ground clamp ~ ~ 16 - 24Vac Detector 1.ȍ + CA38A or RJ31 RED - RING BRN N.C. YEL N.O. - 1KΩ** resistor + 16 - 36Vdc BRN GRY RED G R1 T1 RG TP PHONE LINE C 1 2 3 4 C 5 6 7 8 C ZONES 2-WIRE 13.8 Vdc AUX 700 mA MAX. SMOKE PARADOX.COM Printed in Canada - 12/2008 16 / 24 Vac Telephone lines can be connected directly to the control panel or through a CA38A or RJ31. Connect keyswitches to the keypad, control panel, or zone expansion module's (ZX8D,ZX16D,ZX32D) hardwired input terminals. The control panel includes eight hardwired input terminals for use with traditional hardwired (non-Multibus) door contacts, smoke detectors and/or motion detectors. Additional hardwired devices can be connected using Zone Expansion modules (ZX8D,ZX16D, ZX32D) which are connected to the Multibus. Fire Circuits Using BabyWare, assign the smoke detector connected to the control panel or zone expansion input terminals to a zone and define the zone's parameters as a Fire Zone. Connect 4-wire smoke detectors and a relay as shown in Figure 2. 5 ETHERNET V32 Programmable Outputs The V32 inculdes 5 programmable output relays (PGMs). PGM1 to PGM4 are 100mA (max.) solid-state relays with +/- triggers. PGM5 is a 3A/28Vdc N.O./ N.C. relay output. NOTE: Use external relay if more than 100mA (3A for PGM 5) MULTIBUS RED BLK GRN YEL RS485 ACCESS A+ B- 9 Keypad Z1 PGM RED BLK GRN YEL ETHERNET 10/100 Mbps 11 10 + PS27D Power Supply Figure 2: 4-Wire Smoke 1K9 EOL MULTIBUS RED BLK GRN YEL 8 Release clip 13.8 Vdc AUX Module Module RED BLK GRN YEL RED BLK GRN YEL PS27D Power Supply RED BLK GRN YEL 1 2 PGM 100mA In the event of an alarm, the bell output supplies 12VDC and can support one 30-watt or two 20-watt sirens. If the current exceeds 3A, the bell output will automatically shut down. Input Power 8 External Power Supply 9 Multibus Connections Feed 16-24Vac or 16-36Vdc (40VA / 40W). If the total power drawn from the control panel could exceed 700 mA, modules can be powered using the PS27D or PS817 power supply (see Figure 3). The 4-wire multibus can support up to 511 modules. Use star and/or daisy chain configuration. The total length of wire cannot exceed 914m (3000ft). Before connecting a module to the Multibus, shut down the auxiliary output from the control panel. 10 11 12 Smoke detector C 1 2 ZONES * Follows control panels EOL definition $.ȍUHVLVWRULVUHTXLUHG LIWKHEHOOLVQRWHTXLSSHG with an internal resistor. Position the resistor as closely as possible to the bell. A resistor is not UHTXLUHGIRUVLUHQV Bell/Siren Output 7 Figure 3: Power Supply Connections Smoke detector 35mm DIN rail - Battery 12 MR3 Relay WHT BRN YEL RED BLK COM N.C. N.O. ACM24D RS485 Bus Door Contact To facilitate installation and servicing, the V32 terminals can be detached from the module. Wires can be labeled using the supplied tie wraps. 6 Network 10Base-T 100Base-TX 1 kΩ* Figure 1: DIN Rail Mounting BATTERY 12Vdc M R3-UL The V32 is designed to be mounted on a standard 35mm DIN rail (see Figure 1). Modules can be mounted in a Paradox DIN rail enclosure. Alternatively, using the supplied DIN rail, the V32 can be mounted in any location. To attach the module, align the top of the DIN rail as shown in Figure 1 and apply pressure to the module until it clicks into place. To remove the V32 from a DIN rail, pull the release clip and remove the module. Hardwired Zone Inputs 4 RS485 RX/TX RED BLK GRN YEL Imperial Module Installation 1 2 3 4 COM NC NO BELL PGM PGM 5 100mA 5A USB RX/TX Detector Connect PC users locally through the V32’s built-in USB 2.0 port or remotely through its built-in Ethernet port or via a Paradox GSM module. 3 USB POWER BATTERY TBL RED BLK GRN YEL The V32 communicates with up to 511 bus modules through one 4-wire 13.8Vdc communication bus at 500bps (switches to RS-485 at 57.6Kbps for firmware upgrade). An independent encrypted RS-485 port is also provided which allows stand-alone operation for all ACM24D 2-Door/4-Reader Access Control Modules. Keyswitch Connections USB 2.0 PORT BELL The Paradox Imperial (V32) control panel offers up to 384 zones, 32 partitions, 64 access doors and 999 users. All system functions, such as programming, monitoring and site management, are available through the Imperial PC software (BabyWare). 2 Power supply Instruction Sheet This instruction sheet is intended only as a quick installation reference. For more detailed installation instructions, refer to the Imperial Reference and Installation manual which can be found at paradox.com. Telephone Line Connections 6 5 R-1 V32 Imperial Controller V1.0 1 Keypad Connections Keypads are connected to the control panel's Multibus in a star and/or daisy chain configuration. For instructions on connecting keypad zones and Grafica installations, refer to the Imperial Reference and Installation manual. Ethernet Port Through the Ethernet port, the Imperial includes a built-in communication TCP/IP link. This provides the freedom to monitor the security system and control basic functions remotely using either BabyWare software or through a web browser. Access Control The RS485 Access Port communicates using the high-speed RS485 protocol and is designed to support the ACM24D Access Control Modules. Manual Control Buttons AUX Button BELL Button PGM Buttons The Imperial control panel supplies 700mA to power security system modules. By pressing the AUX button, the 13.8VDC auxiliary power supply can be manually activated (LED on) or deactivated (LED off), allowing modules to be powered down without shutting down the control panel. Used when testing the system, pushing the BELL button activates the bell/siren. The bell/siren will remain activated (LED on) for one minute (max.) or until the button is pushed again. The Imperial control panel is equipped with 5 PGMs (programmable outputs). PGMs are usually assigned and triggered through BabyWare software. PGMs can also be manually activated (LED green) or deactivated (LED red) using the PGM buttons. Using the PGM buttons overrides any PGM programming in BabyWare. Once a PGM button is pushed, the PGM will remain in that state until either the button is pushed again, or until the PGM is triggered by BabyWare. LED PGM LEDs 1 to 5 red green USB 2.0 PORT BELL Colour Condition PGM is in normal state PGM is in opposite state USB POWER BATTERY TBL USB RX/TX RS485 RX/TX ETHERNET V32 LED Feedback The Imperial control panel includes a 17-LED display, which provides feedback to aid in installation troubleshooting as well as giving the user and installer important information on system status. MULTIBUS Table 1: Multibus LEDs TX Condition RX OFF OFF RED ON green - flash green - flash OK (panel communication in progress) off off OK (no data RX/TX) off off Short on GRN or YEL Communication failure / Too many modules RED ON off green on Multibus RED ON green green Multibus lines reversed (Green / Yellow) RED FLASH off off Bus power too low BLUE ON ----Multibus mode (firmware upgrade) BLUE off off Firmware upgrade in progress FLASH Table 2: Imperial LEDs LED Colour Condition AC CHARGE green green off External power supply is OK Battery charging / Battery in test mode No battery / Battery fully charged No battery / Battery malfunction / Wrong Connection BATTERY TBL DIALER red green - slow flash (flash every sec.) green - slow flash (1 sec. on / 1 sec. off) green TLM test - line is available TLM test - no line available Panel is using the line Technical Specifications Table 3: Communication LEDs Condition LED Colour USB POWER RX/TX USB RX/TX RS485 amber green - fast flash green green - fast flash random green green - fast flash random ETHERNET PC connected USB communication in progress Power supplied to RS485 access port RS485 communication in progress Network cable connected Ethernet communication in progress Power Input Voltage: 16-24Vac (50-60Hz) / 16-36Vdc Power Input Rating: 40VA / 40W Auxiliary Output Power 12Vdc 600mA typical, 700mA maximum, fuseless shutdown at 1.1A Rated to operate between 10.8Vdc and 13.8Vdc Battery: 12Vdc, 7Ah minimum Bell Output: 1A, fuseless shutdown @ 3A PGM Output: PGM1 to PGM4 100mA solid-state relays with +/- internal trigger PGM5 Form C relay output rated at 3A / 28Vdc N.O. / N.C. Operational Temp: 0°C to +50°C (32°F to +122°F) Warranty For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions. Paradox Imperial and BabyWare are trademarks or registered trademarks of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries. For the latest information on products approvals, such as UL and CE, please visit www.paradox.com. © 2008 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply. Canadian and international patents may also apply.