Uploaded by prpr101972

Imperial (Paradox) V32 spec

advertisement
V32-EQ00
1
TM
N/U
2
N/U
3
7
4
GRN TIP
ALARM RELAY TAMPER
OUTPUT
N.O.COM N.C. COM N.C.
keyswitch
T-1
RED
2-wire smoke
Cold water
pipe grounding
BLK
Power supply
or
MR3-UL Relay
WHT
COM
GRN
Ground
clamp
~
~
16 - 24Vac
Detector
1.ȍ
+
CA38A
or RJ31
RED
-
RING
BRN
N.C.
YEL
N.O.
-
1KΩ**
resistor
+
16 - 36Vdc
BRN
GRY
RED
G R1 T1 RG TP
PHONE LINE
C 1 2 3 4 C 5 6 7 8 C
ZONES
2-WIRE
13.8 Vdc AUX
700 mA MAX.
SMOKE
PARADOX.COM
Printed in Canada - 12/2008
16 / 24 Vac
Telephone lines can be connected directly to the control panel or through a CA38A or
RJ31.
Connect keyswitches to the keypad, control panel, or zone expansion module's
(ZX8D,ZX16D,ZX32D) hardwired input terminals.
The control panel includes eight hardwired input terminals for use with traditional
hardwired (non-Multibus) door contacts, smoke detectors and/or motion detectors.
Additional hardwired devices can be connected using Zone Expansion modules
(ZX8D,ZX16D, ZX32D) which are connected to the Multibus.
Fire Circuits
Using BabyWare, assign the smoke detector connected to the control panel or zone
expansion input terminals to a zone and define the zone's parameters as a Fire
Zone.
Connect 4-wire smoke detectors and a relay as shown in Figure 2.
5
ETHERNET
V32
Programmable Outputs
The V32 inculdes 5 programmable output relays (PGMs). PGM1 to PGM4 are
100mA (max.) solid-state relays with +/- triggers. PGM5 is a 3A/28Vdc N.O./ N.C.
relay output.
NOTE: Use external relay if more than 100mA (3A for PGM 5)
MULTIBUS
RED BLK GRN YEL
RS485 ACCESS
A+ B-
9
Keypad
Z1 PGM RED BLK GRN YEL
ETHERNET
10/100 Mbps
11
10
+
PS27D
Power Supply
Figure 2: 4-Wire Smoke
1K9
EOL
MULTIBUS
RED BLK GRN YEL
8
Release
clip
13.8 Vdc AUX
Module
Module
RED BLK GRN YEL
RED BLK GRN YEL
PS27D
Power Supply
RED BLK GRN YEL
1 2
PGM
100mA
In the event of an alarm, the bell output supplies 12VDC and can support one 30-watt
or two 20-watt sirens. If the current exceeds 3A, the bell output will automatically shut
down.
Input Power
8
External Power Supply
9
Multibus Connections
Feed 16-24Vac or 16-36Vdc (40VA / 40W).
If the total power drawn from the control panel could exceed 700 mA, modules can
be powered using the PS27D or PS817 power supply (see Figure 3).
The 4-wire multibus can support up to 511 modules. Use star and/or daisy chain
configuration. The total length of wire cannot exceed 914m (3000ft).
Before connecting a module to the Multibus, shut down the auxiliary output
from the control panel.
10
11
12
Smoke
detector
C 1 2
ZONES
* Follows control panels
EOL definition
$.ȍUHVLVWRULVUHTXLUHG
LIWKHEHOOLVQRWHTXLSSHG
with an internal resistor.
Position the resistor as
closely as possible to the
bell. A resistor is not
UHTXLUHGIRUVLUHQV
Bell/Siren Output
7
Figure 3: Power Supply Connections
Smoke
detector
35mm
DIN rail
-
Battery
12
MR3 Relay
WHT BRN YEL RED BLK
COM N.C. N.O.
ACM24D
RS485
Bus
Door Contact
To facilitate installation and servicing, the
V32 terminals can be detached from the
module. Wires can be labeled using the
supplied tie wraps.
6
Network
10Base-T
100Base-TX
1 kΩ*
Figure 1: DIN Rail Mounting
BATTERY
12Vdc
M R3-UL
The V32 is designed to be mounted on a
standard 35mm DIN rail (see Figure 1).
Modules can be mounted in a Paradox DIN
rail enclosure. Alternatively, using the
supplied DIN rail, the V32 can be mounted
in any location. To attach the module, align
the top of the DIN rail as shown in Figure 1
and apply pressure to the module until it
clicks into place. To remove the V32 from a
DIN rail, pull the release clip and remove
the module.
Hardwired Zone Inputs
4
RS485 RX/TX
RED BLK GRN YEL
Imperial
Module
Installation
1 2 3 4 COM NC NO
BELL
PGM
PGM 5
100mA
5A
USB RX/TX
Detector
Connect PC users locally through the
V32’s built-in USB 2.0 port or remotely
through its built-in Ethernet port or via a
Paradox GSM module.
3
USB POWER
BATTERY TBL
RED BLK GRN YEL
The V32 communicates with up to 511 bus
modules through one 4-wire 13.8Vdc
communication bus at 500bps (switches to
RS-485 at 57.6Kbps for firmware upgrade).
An independent encrypted RS-485 port is
also provided which allows stand-alone
operation for all ACM24D 2-Door/4-Reader
Access Control Modules.
Keyswitch Connections
USB 2.0
PORT
BELL
The Paradox Imperial (V32) control panel
offers up to 384 zones, 32 partitions, 64
access doors and 999 users. All system
functions, such as programming,
monitoring and site management, are
available through the Imperial PC software
(BabyWare).
2
Power supply
Instruction Sheet
This instruction sheet is intended only as a
quick installation reference. For more
detailed installation instructions, refer to the
Imperial Reference and Installation manual
which can be found at paradox.com.
Telephone Line Connections
6
5
R-1
V32 Imperial Controller
V1.0
1
Keypad Connections
Keypads are connected to the control panel's Multibus in a star and/or daisy chain
configuration. For instructions on connecting keypad zones and Grafica installations,
refer to the Imperial Reference and Installation manual.
Ethernet Port
Through the Ethernet port, the Imperial includes a built-in communication TCP/IP
link. This provides the freedom to monitor the security system and control basic
functions remotely using either BabyWare software or through a web browser.
Access Control
The RS485 Access Port communicates using the high-speed RS485 protocol and is
designed to support the ACM24D Access Control Modules.
Manual Control Buttons
AUX Button
BELL Button
PGM Buttons
The Imperial control panel supplies 700mA to power security system
modules. By pressing the AUX button, the 13.8VDC auxiliary power supply
can be manually activated (LED on) or deactivated (LED off), allowing
modules to be powered down without shutting down the control panel.
Used when testing the system, pushing the BELL button activates the bell/siren.
The bell/siren will remain activated (LED on) for one minute (max.) or until the
button is pushed again.
The Imperial control panel is equipped with 5 PGMs (programmable outputs). PGMs are
usually assigned and triggered through BabyWare software. PGMs can also be manually
activated (LED green) or deactivated (LED red) using the PGM buttons. Using the PGM
buttons overrides any PGM programming in BabyWare. Once a PGM button is pushed,
the PGM will remain in that state until either the button is pushed again, or until the PGM
is triggered by BabyWare.
LED
PGM LEDs 1 to 5 red
green
USB 2.0
PORT
BELL
Colour
Condition
PGM is in normal state
PGM is in opposite state
USB POWER
BATTERY TBL
USB RX/TX
RS485 RX/TX
ETHERNET
V32
LED Feedback
The Imperial control panel includes a 17-LED display, which provides feedback to aid in
installation troubleshooting as well as giving the user and installer important information
on system status.
MULTIBUS
Table 1: Multibus LEDs
TX
Condition
RX
OFF
OFF
RED ON
green - flash green - flash OK (panel communication in progress)
off
off
OK (no data RX/TX)
off
off
Short on GRN or YEL
Communication failure / Too many modules
RED ON
off
green
on Multibus
RED ON
green
green
Multibus lines reversed (Green / Yellow)
RED FLASH off
off
Bus power too low
BLUE ON
----Multibus mode (firmware upgrade)
BLUE
off
off
Firmware upgrade in progress
FLASH
Table 2: Imperial LEDs
LED
Colour
Condition
AC
CHARGE
green
green
off
External power supply is OK
Battery charging / Battery in test mode
No battery / Battery fully charged
No battery / Battery malfunction /
Wrong Connection
BATTERY TBL
DIALER
red
green - slow flash
(flash every sec.)
green - slow flash
(1 sec. on / 1 sec. off)
green
TLM test - line is available
TLM test - no line available
Panel is using the line
Technical Specifications
Table 3: Communication LEDs
Condition
LED
Colour
USB POWER
RX/TX USB
RX/TX RS485
amber
green - fast flash
green
green - fast flash random
green
green - fast flash random
ETHERNET
PC connected
USB communication in progress
Power supplied to RS485 access port
RS485 communication in progress
Network cable connected
Ethernet communication in progress
Power Input
Voltage:
16-24Vac (50-60Hz) / 16-36Vdc
Power Input
Rating:
40VA / 40W
Auxiliary
Output Power
12Vdc 600mA typical, 700mA maximum, fuseless shutdown at 1.1A
Rated to operate between 10.8Vdc and 13.8Vdc
Battery:
12Vdc, 7Ah minimum
Bell Output:
1A, fuseless shutdown @ 3A
PGM Output:
PGM1 to PGM4 100mA solid-state relays with +/- internal trigger
PGM5 Form C relay output rated at 3A / 28Vdc N.O. / N.C.
Operational
Temp:
0°C to +50°C (32°F to +122°F)
Warranty
For complete warranty information on this product please refer to the Limited Warranty
Statement found on the website www.paradox.com/terms. Your use of the Paradox
product signifies your acceptance of all warranty terms and conditions.
Paradox Imperial and BabyWare are trademarks or registered trademarks of Paradox
Security Systems Ltd. or its affiliates in Canada, the United States and/or other
countries. For the latest information on products approvals, such as UL and CE,
please visit www.paradox.com.
© 2008 Paradox Security Systems Ltd. All rights reserved. Specifications may change
without prior notice. One or more of the following US patents may apply: 7046142,
6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069,
5077549 and RE39406 and other pending patents may apply. Canadian and
international patents may also apply.
Download