Uploaded by Abhiraj Chahal

CASE STYDY PPT

advertisement
FOOTBALL STADIUM
CASE STUDY PRESENTATION
CONTENT
01
JAWAHARLAL NEHRU
STADIUM, NEW DELHI
02
SREE KANTEERAVA
STADIUM,BENGALURU
JAWAHARLAL NEHRU
STADIUM STADIUM, NEW DELHI
Jawaharlal Nehru Stadium is a sports
stadium located in New Delhi, India.
The Stadium was constructed by
the Government of India to host the
athletic events and ceremonies of
the 1982 Asian Games.
It is designed and constructed to meet the
international standards for stadiums set by
the Asian Football Confederation (AFC),
the International Federation of Association
Football (FIFA) and the International
Association of Athletics Federations (IAAF).
The stadium was renovated for
the 2010 Commonwealth Games,
was redesigned by the German
architectural companies Gerkan,
Marg and Partners and Schlaich
Bergermann & Partner.
ABOUT :
LOCATION :
The Jawaharlal Nehru Stadium is
located in Pragati vihar, New Delhi.
AREA : 100 acres
F.A.R : 40%
GROUND COVERAGE : 70965.45
sqm
TOPOGRAPHY : Plain
CLIMATE : Composite climate
India map
Delhi map
PROXIMITY MAP :
…
…
…
…
1kmradius
…… 2km radius
……
3
… …
km
Macro Proximity
s
iu
rad
日
ISBT : 16.8 km
RAILWAY STATION : 1.5 km
AIRPORT: 15.4 km
Micro Proximity
METRO STATIONS
ACCESS ROADS AND SURROUNDINGS :
Complex road
17 m wide road.
Bhishama Pitamah marg
23 m wide road.
CGO Complex
Lodhi road
quaters
SITE ZONING AND ENTRY/EXITS :
Sports facilities –
Tennis court,
Basketball,
Badminton,
Football
Auditorium
Main Stadium
Parking
area
Sports facilities –
Football,
Athletics warm up area
SAI Hostel
Entry and Exit
SITE CIRCULATION :
Road from main gate 1
Vehicular acess checkpoint
Games family load zone
Athletes load zone
Media load zone
Games family flow
Athletes/Technical officials flow
Media flow
SITE CIRCULATION :
1
2
1,2 -Plaza
Paved area
Road
Spectator movement
Service flow
Vehicle movement
GENERAL FEATURES:
o The west part of the stadium is earmarked for VIP and
remaining for general public.
o There are 14 circular ramps for upper concourse.
o There are 8 public entry gates on 1
o
st
floor.
Seating capacity : Total 60,000.
- West block : 2331 (VIP- 1637, VVIP- 394,
Media- 300)
- South block : 2598
Way to ramps for upper concourse
VIPSeating
- North block : 3387
- East block : 4528
- lose media chair : 3165
- Upper concourse : 44,000
o
Parking area –
- Surface parking : 480 cars ; 50 buses
- Basement parking (auditorium) : 270 cars
Ramp for upper concourse
View from VIP box
o Score board supplied by SWISS.
o
15 nos. machine room lifts.
o 2 nos. escalators.
Digital lighting controls for concourse and spectator
lights
o
o Football field is of natural grass.
o
Toilets –
- Gents : 52 Nos.
- Ladies : 49 Nos.
Score board
Escalator and lift
Football field
Digital lighting
STRUCTURE DETAIL :
o Two tier seating arrangement
o
Earthquake resistant building
o RCC structure of oval shaped building
o
Independent steel frame for Poly Tera Fluoro Ethylene
roofing over spectators stand
o The roof –
Area : 45000 sqm
Roof depth : 70 m
The elliptical steel structure was installed around the
stadium
to hold the two compression rings for the membrane roof.
The steel compression ring supports the tensile roof’s
cable net system.
The gap between the cable net system is filled with PTFE
sheer panels.
STRUCTURE DETAIL :
o The two outer supporting colonnade structure carrying both
the compression rings and complete ramp system for access
and evacuation.
EXISTING FUNCTIONS :
FLOOR PLANS :
Ground floor plan
FLOOR PLANS :
First floor plan
FLOOR PLANS :
Second floor plan
Services :
There are 4 no. 11 KV sub-stations and 1 no. 33 KV substation.
o For adequate backup DG sets are there (19 no.)
o
Digital lighting controls for concourse lights.
o
Underground water reservoir and pump room consists of
- Fire tank cap. 1 lac lts. (2 no.)
- Flushing water tank cap. 72,000.
- HVAC raw water cap. 2,30,000 lts.
KEY PLAN
- HVAC treated water cap. 2,30,000 lts.
- Domestic water tank cap. 90,000 lts.
Location of sub-station
Sub-station
Location of underground water
reservoir and pump room
SITE PICTURES :
2
1
5
3
4
1
3
2
MAIN ENTERANCE TO
THE STADIUM
LANDSCAPE AREA
PERIPHERAL ROAD
KEY PLAN
4
PARKING AREA
5
ATHLETIC AND FOOTBALL PRACTICE FIELD
SITE PICTURES :
7
6 ) BASKETBALL COURT
7
FOOTBALL FIELD
6
8
SEATING AROUND BASKETBALL COURT
WASTE DISPOSAL AREA
9
8
6
KEY PLAN
9
BADMINTON COURT
SITE PICTURES :
FOOTBALL FIELD
CHANGE ROOM
HOSTEL
WEIGHTLIFTING AREA
RESTROOM
SREE KANTEERAVA STADIUM
BENGALURU,INDIA
Sree Kanteerava Stadium, is a multipurpose stadium in Bengaluru, India. It
is used mostly for football matches.
It is Bengaluru's main sports stadium
and several national level teams hold
their training sessions here. The
stadium was built on top of an old
lake.
The Sree Kanteerva athletic track
was developed into a pro synthetic
track for 1997 national games
before which it was a cinder track.
ABOUT :
LOCATION :
Sree Kanteerava Stadium is located in
Sampangi Rama Nagara, Bengaluru, Karnataka.
AREA : 29.8 acres
F.A.R : 40%
GROUND COVERAGE : 72,844 sqm
TOPOGRAPHY : Plain
CLIMATE : Tropical wet and dry climate.
India map
Bengaluru map
PROXIMITY MAP :
1 km radius
、
2 km radius
……3km radius………
Macro Proximity
Micro Proximity
日
ISBT : 3.5 km
RAILWAY STATION : 3.9 km
AIRPORT: 36.6 km
METRO STATIONS
ACCESS ROADS AND SURROUNDINGS :
St. Joseph’s Indian High
School
Kasturba road
16 m wide road.
Vittal malya road
16 m wide road.
Commercial area
SITE ZONING AND ENTRY/EXITS :
Hostels, Offices
Main Stadium
Parking
area
Sports facilities –
Athletics warm up area,
Tennis court
Indoor
stadium
…
Entry and Exit
SITE CIRCULATION :
Gate-A
Games family flow
Athletes/Technical officials flow
Media flow
SITE CIRCULATION :
Main Enterance
Spectator movement
Service flow
Vehicle movement
GENERAL FEATURES:
o The west part of the stadium is earmarked for VIP and
remaining for general public.
o There are 14 circular ramps for upper concourse.
o There are 5 public entry gates to site.
o Seating capacity : Total 30,000.
o Parking area –
- Surface parking :
Outdoor stadium – 150 cars ; 2 wheeler (2000)
Way to VIP seating
VIPSeating
Indoor stadium – 65 cars ; 2 wheeler (1000)
o One score board
o 3 glass house on 1 st floor
o 8 dormitory with attached toilet and 12 other dormitory
o 171 toilets in total of male and female.
Glass house
Entry gate to stadium
STRUCTURE DETAIL :
o Two tier seating arrangement
o Earthquake resistant building
o RCC structure
o Tension ring roofing system over spectators stand
o The roof –
A roof structure suitable only for circular/elliptical stadiums is
the compression/tension ring
system. Such a roof consists of a compression ring around the
exterior and a tension ring on the
inside
Services :
o There are 6 no. generator separate in outdoor stadium
o 4 towers of Floodlights (220’ high).
o Per hour diesel for all the generators – 60l.
o 3 2 5 0 kv captive power plant was installed.
o Generator –
- 1 for cooling
- 4 running generator
- 1 for emergency case
o 1.5 lac litre water tank
o Fire extinguishers 48 in no.
SITE PICTURES :
Players Dugout
VIP area
Main field
PARKING AREA
Natural grass field
ATHLETIC AND FOOTBALL PRACTICE FIELD
SITE PICTURES :
Hostel
Volleyball court
Restaurant
Basketball court
Indoor stadium
Gym
Download