Uploaded by maharanapratapknight

SZ ds

advertisement
General Purpose
Power Relay
FEATURES
• Small package design
• ARC barrier equipped
• Silver Cadium Oxide
contact
• High dielectric strength
(1,800 Vac)
• High reliability and long life
• Ultra-high sensitivity with
quick response time
(25 ms max.)
• High vibration and shock
resistance
• Options include LED
indicator, diode protection,
and LED indicator/diode
protection
• UL listed, CE certified,
CSA certified
TYPICAL APPLICATIONS
• Control panels
• Elevator panels
• Machine tools
• Test equipment
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
Sensing and Control
SZR-LY Series
®
SZR-LY Series general-purpose power relays are designed for a wide
range of applications including power as well as logic control for factory
machines and control panels.
SZR-LY Series relays break 10 A loads and are ideal for control panels
that require stable and reliable relays.
One standard and three options are available: LED indicator, internal
surge protection diode, and LED indicator/diode protection. Honeywell’s
global sales and distribution channels ensure a rapid response and excellent
customer service.
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for reference only. Do
not use this document as a product installation guide.
• Complete installation, operation, and maintenance information is provided
in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
General Purpose
Power Relays
SZR-LY Series
RELAY MODEL SELECTION GUIDE
Type
Terminal
Standard
Plug-in/Solder
PCB
LED Indicator
Plug-in/Solder
DIODE surge suppression
LED indicator + surge suppression
Contact
Catalog Listing
DPDT
SZR-LY2-1
4PDT
SZR-LY4-1
DPDT
SZR-LY2-1P
4PDT
SZR-LY4-1P
DPDT
SZR-LY2-N1
4PDT
SZR-LY4-N1
DPDT
SZR-LY2-D1
4PDT
SZR-LY4-D1
DPDT
SZR-LY2-X1
4PDT
SZR-LY4-X1
SOCKETS – REQUIRED ACCESSORIES
Din-rail Mounting
Solder Terminal
PCB Terminal
SZX-SLF-08N
SZX-SLB-08
SZX-SLB-08P
SZX-SLF-14
SZX-SLB-14
SZX-SLB-14P
Relay Contact
DPDT
For use with
SZR-LY2-1, N1, -D1, -X1
4PDT
For use with
SZR-LY4-1, N1, -D1, -X1
CONTACT RATINGS
Load
Ratings
Rated load
Carry current
Max. operating voltage
Max. operating current
Max. switching capacity
Min. permissible load
2 Honeywell • Sensing and Control
Resistive Load
(p.f. = 1)
Inductive load
(p.f. = 0.4, L/R = 7 ms)
110 Vac, 10 A
24 Vdc, 10 A
110 Vac, 7.5 A
24 Vdc, 5 A
10 A
250 Vac, 125 Vdc
10 A
1,100 VA, 240 W
825 VA, 120 W
5 Vdc, 100 mA
General Purpose
Power Relays
SZR-LY Series
COIL RATINGS (DPDT)
Rated
Voltage
(V)
AC
DC
6
12
24
50
100/110
110/120
200/220
220/240
6
12
24
48
100/110
Rated Current (mA)
50 Hz
60 Hz
214.1
106.5
53.8
25.7
11.7/12.9
9.9/10.8
6.2/6.8
4.8/5.3
183
91
46
22
10/11
8.4/9.2
5.3/5.8
4.2/4.6
150
75
36.9
18.5
9.1/10
Coil
resistance
(Ω)
Coil Inductance (H)
Armature
Armature
OFF
ON
12.2
46
180
788
3,750
4,430
12,950
18,790
0.04
0.17
0.69
3.22
14.54
19.2
54.75
83.5
0.08
0.33
1.3
5.66
24.6
32.1
94.07
136.4
40
160
650
2,600
11,000
0.17
0.73
3.2
10.6
45.6
0.33
1.37
5.72
21.0
86.2
Pick-up
Voltage
(V)
Max.
80 %
Dropout
Voltage
(V)
Min.
30%
Maximum
Voltage
(V)
Power
Consumption
(W)
Approx.
1.0 W to 1.2 W
(60 Hz)
110%
Approx
0.9 W to 1.1 W
(60 Hz)
Max.
80%
Min.
10%
110%
Approx.
0.9 W
Pick-up
Voltage
(V)
Dropout
Voltage
(V)
Maximum
Voltage
(V)
Power
Consumption
(W)
Max.
80 %
Min.
30%
110%
Approx.
1.95 W to 2.5 W
(60 Hz)
Max.
80%
Min.
10%
110%
Approx.
1.5 W
COIL RATINGS (4PDT)
Rated Current (mA)
AC
DC
Coil Inductance (H)
Rated
Voltage
(V)
50 Hz
60 Hz
Coil
resistance
(Ω)
Armature
OFF
Armature
ON
6
12
24
50
100/110
200/220
386
199
93.6
46.8
22.5/25.5
11.5/13.1
330
170
80
40
19/21.8
9.8/11.2
5
20
78
350
1,800
6,700
0.02
0.1
0.38
1.74
10.5
33.1
0.04
0.17
0.67
2.88
17.3
57.9
25
100
350
1,600
6,900
0.09
0.39
1.41
6.39
32
0.21
0.84
2.91
13.6
63.7
6
12
24
48
100/110
240
120
69
30
15/15.9
Note 1: The rated current and coil resistance are measured at a coil temperature of 23 °C [73.4 °F] with tolerances of +15%,
-20% for AC rated current and ± 15% for DC coil resistance.
Note 2: The rated current of N1 and X1 types is 4 mA higher than the value in the table above.
Honeywell • Sensing and Control
3
General Purpose
Power Relays
SZR-LY Series
SPECIFICATIONS
Contact material
Contact resistance
Operate time
Release time
Operating
Mechanical
frequency
Electrical
Silver Cadium Oxide
Max. 50 MOhm
Max. 25 ms
Max. 25 ms
18,000 operations per hour
1,800 operations per hour
Insulation resistance
Dielectric withstand voltage
Min. 100 Mw at 500 Vdc
1,800 Vac 50 Hz/60 Hz for one minute between non-continuous current
carrying terminals and between coil thermals and contact terminals
1,000 Vac 50/60 Hz for 1 minute between contacts of same polarity
Vibration
Mechanical durability
10 Hz to 55 Hz at double amplitude of 1.0 mm
resistance
Malfunction durability
10 Hz to 55 Hz at double amplitude of 1.0 mm
Shock resistance Mechanical durability
1,000 m/s2 (approx. 100 g)
Malfunction durability
200 m/s2 (approx. 20 g)
Service life
Mechanical
AC: Min. 50 million operations (at operating frequency of 18,000 operations/hour)
DC: Min. 100 million operations (at operating frequency of 18,000 operations/hour)
Electrical
DPDT: Min. 500,000 operations (at operating frequency of 1,800 operations/hour)
4PDT: Min. 200,000 operations (at operating frequency of 1,800 operations/hour)
Weight
DPDT: Approximately 35 g 4PDT: Approximately 65 g
Note 1: The data shown above are of initial value
CHARACTERISTIC DATA
Electrical life
)
4
AC resistive
10
5
AC inductive
p.f.=0.4
DC resistive
1
0.5
DC inductive
L/R=7ms
0.1
5 10
Number of operations(× 10
DPDT
Rated operatin g current(A)
Max. Switching capacity
1,000
500
DC24V resistive load
AC110V resistive load
100
50
DC24V
(L/R=7ms)
10
0
50 100
500
Rated operating voltage(V)
2 4
8 10 12
14 16
Current(A)
4
)
AC resistive
10
5
AC inductive
p.f.=0.4
DC resistive
1
0.5
DC inductive
L/R=7ms
0.1
5 10
50 100
500
Rated operating voltage(V)
4 Honeywell • Sensing and Control
Number of operations(× 10
Rated operating current(A)
6
Electrical life
Max. Switching capacity
4PDT
AC110V
(cosf =0.4)
1,000
500
DC24V resistive load
AC110V resistive load
100
50
10
DC24V
(L/R=7ms)
AC110V
(cosf =0.4)
0
2 4
6
8 10 12
14 16
Current(A)
General Purpose
Power Relays
SZR-LY Series
CATALOG LISTING MATRIX
SZR – LY 2 – ___
1
P – AC110-120V
Terminal Type
__ = Solder/Plug-in
P = PCB
Mounting Type
1 = Terminal
Poles
2 = DPDT
4 = 4PDT
Amp Rating:
MY = 5 A or 3 A
LY = 10 A
Product Type
General Purpose Relay
Honeywell • Sensing and Control
Option Type
__ = No Indicator or Diode
D = Internal Surge Protection Diode
N = Red LED Operation Indicator
X = LED and Diode
Voltage Rating:
AC6V
=
AC12V
=
AC24V
=
AC50V
=
AC100V
=
AC110-120V =
AC200V
=
AC220V
=
AC220-240V =
DC6V
=
DC12V
=
DC24V
=
DC48V
=
DC100V
=
6 Vac
12 Vac
24 Vac
50 Vac
100 Vac
110/120 Vac
200 Vac
220 Vac
220/240 Vac *
6 Vdc
12 Vdc
24 Vdc
48 Vdc
100 Vdc
240 Vac - Submitted for UL approval
5
General Purpose
Power Relays
SZR-LY Series
HOLDING CLIPS
•
•
•
•
•
Holding clips are included with the sockets
Holding clips for the SLF-08N cannot be removed once inserted
The holding clip for the SLF-14 can be removed by pushing the side of the inserting hold with a sharp object
Holding clips for all SMB sockets are wire for easy removal
Holding clips are to be inserted into the slots provided on the socket
DIMENSIONS (For reference only – mm/in)
Figure 1. Dimensions
For SZX-SLF-14 sockets
Figure 3. Dimensions
For all SZX-SLB sockets
29,0 [1.14]
4,5
[0.18]
22,0 [0.87]
16,0 [0.63]
39,6 [1.56]
4,5
[0.18]
7,0
[0.28]
6,0
[0.24]
45,5 [1.79]
Figure 2. Dimensions
For SZX-SLF-08N sockets
6,5
[0.26]
5,0
[0.20]
14,5
[0.57]
4,6 [0.18]
49,9 [1.96]
6 Honeywell • Sensing and Control
6,2
[0.24]
2,2
[0.09
]
15°
General Purpose
Power Relays
SZR-LY Series
5,75
[0.23]
Max. 28,0 [1.10]
14 - O 3,0 [0.12]
5,0
[0.20]
0,5
[0.02]
FIGURE 4. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR
SZR-LY2-1, SZR-LY2-N1, SZR-LY2-D1, and SZR-LY2-X1
3,0 [0.12]
Max. 36,0 [1.42]
LY2-1
Max. 21,5
[0.85]
6,4 [0.26]
LY2-N1 AC
LY2-N1 DC
LY2-D1
LY2-X1
1
2
1
2
1
2
1
2
1
2
3
4
3
4
3
4
3
4
3
4
5
6
5
6
5
6
5
7
8
7
8
7
8
7
-
+
-
+
6
5
8
7
6
-
+
8
Bottom view
1,0
[0.04]
Max. 36,0 [1.42]
Max. 28,0 [1.10]
5,75
[0.23]
2,0
[0.08]
0,5
[0.02]
FIGURE 5. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR
SZR-MY2-1P and SZR-MY4-1P
Max. 21,5 [0.85]
4,5
[0.18]
The circuit diagram is the same wit standard type of SZR-MY2-1 or the SZR-MY4-1
Honeywell • Sensing and Control
7
General Purpose
Power Relays
SZR-LY Series
0,5
[0.02]
FIGURE 6. DIMENSION, CIRCUIT DIAGRAM, TERMINAL ARRANGEMENT, AND MOUNTING HOLE FOR
SZR-LY4-1, SZR-LY4-N1, SZR-LY4-D1, and SZR-LY4-X1
5,0
[0.20]
Max. 28,0 [1.10]
14 - O 3.0 Holes
3,0
[0.12]
Max. 36,0 [1.42]
Max. 41,5 [1.63]
6,4 [0.25]
LY4-1
LY4-N1 AC
LY4-N1 DC
1
2
3
4
1
2
3
4
1
2
3
4
5
6
7
8
5
6
7
8
5
6
7
8
9
10
11
12
9
10
11
10
11
14
13
13
LY4-D1
12
9
14
13
LY4-X1
1
2
3
4
1
2
3
4
5
6
7
8
5
6
7
8
10
11
12
9
10
11
9
13
-
-
+
13
14
12
-
+
14
Bottom view
FIGURE 7. CIRCUIT DRAWING FOR SZR-LY2- and SZR-LY4-
DPDT
14.2
4PDT
14- 2.5
0.1
10
10
10
3.4
8 Honeywell • Sensing and Control
8- 2.5
0.1
5.3
7.15
5.5
13.15
4.1
4.6
10
12
+
14
General Purpose
Power Relays
SZR-LY Series
SOCKETS
FIGURE 9. SZX-SLF-14
22,0 [0.87]
2 - O 6,0 [0.24] 7,0
[0.28]
14-M3.5x8
3,4 [0.13]
2-M4
14,5
[0.57]
35,5 [1.40]
68,0 [2.68]
47,0
[1.85]
4,2
[0.17]
67,0 [2.64]
36,0 ± 0,2
[1.42 ± 0.008]
8,0
[0.31]
Max. 45,5
[1.79]
Max. 30,0 [1.18]
30,0 [1.18]
Max. 66,0 [2.60]
Max. 61,0 [2.40]
25,0 [0.99]
FIGURE 10. SZX-SLB-08
FIGURE 11. SZX-SLB-14
Max. 42,5 [1.67]
5,0
[0.20]
Max. 29,5 [1.16]
14 - O 1,7 [0.07] Holes
8 - O 1,7 [0.07]
2,7
[0.11]
Max. 26,5
[1.04]
2,7
[0.11]
25,8 ± 0,2
[1.02 ± .008]
38,5
[1.52]
Max. 20,5
[0.81]
Max. 20,5
[0.81]
Max. 21,4 ± 0,2
[0.84 ± .008]
Max. 29,5 [1.16]
26,6 ± 0,3
[1.05 ± 0.01]
Max. 25,5
[1.00]
5,0
[0.20]
0,3
[0.01]
Max. 24,0
[0.94]
38,5 [1.52]
2,5
[0.10]
2 - M4
2 - O 4,5 [0.18] Holes
26,0
[1.02]
4,5
[0.18]
25,0 ± 0,2
[0.99 ± .008]
Max. 78,5 [3.09]
19,0
[0.75]
8,0
[0.31]
69,0 ± 0,3
[2.72 ± 0.01]
FIGURE 8. SZX-SLF-08N
41,0 ± 0,2
[1.61 ± 0.008]
Honeywell • Sensing and Control
9
General Purpose
Power Relays
SZR-LY Series
FIGURE 12. SZX-SLB-08P
Max. 16,5
[0.65]
4,5 [0.18]
Max. 24,0
[0.94]
17,1 [0.67]
Max. 29,5 [1.16]
6,5 [0.26]
10,0
[0.39]
6,0
[0.24]
30,0 [1.18]
Max. 16,5
[0.65]
5,2
[0.20]
4,6
[0.18]
8 - O 2,0 [0.08] Holes
Max. 26,5
[1.04]
2,7
[0.11]
38,5 [1.52]
11,5
[0.45]
12,5
[0.50]
6,5
[0.26]
6,5
[0.26]
5,8
[0.23]
5,0
[0.20]
2,0 [0.08]
Max. 42,5
[1.67]
Max. 29,5 [1.16]
Max. 25,5
[1.00]
5,0
[0.20]
2,0
[0.08]
10,0
[0.39]
38,5
[1.52]
1,0
[0.04]
4,5
[0.18]
0,5
[0.02]
1,0 [0.04]
0,5
[0.02]
2,7
[0.11]
FIGURE 13. SZX-SLB-14P
14 - O 2,0 [0.08] Holes
6,5
[0.26]
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as
being free of defective materials and faulty
workmanship. Contact your local sales office for
warranty information. If warranted goods are returned
to Honeywell during the period of coverage,
Honeywell will repair or replace without charge those
items it finds defective. The foregoing is Buyer’s
sole remedy and is in lieu of all other warranties,
expressed or implied, including those of
merchantability and fitness for a particular
purpose.
Specifications may change without notice. The
information we supply is believed to be accurate and
reliable as of this printing. However, we assume no
responsibility for its use.
Sensing and Control
www.honeywell.com/sensing
Honeywell
11 West Spring Street
Freeport, Illinois 61032
009551-4-EN IL50 GLO 0104 Printed in USA
Copyright 2003-2004 Honeywell International Inc. All Rights Reserved.
While we provide application assistance personally,
through our literature and the Honeywell web site, it
is up to the customer to determine the suitability of
the product in the application.
For application assistance, current specifications,
or name of the nearest Authorized Distributor, contact
a nearby sales office. Or call:
1-800-537-6945 USA/Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
info.sc@honeywell.com
Download