Ilustration 1 Column Rebar Rockwool Column Sleeve polystyrene plates 0.16 m 0.40 m 0.40 m 0.40 m 0.40 m 0.40 m Vertical Reinforcement Horizontal Reinforcement 0.65 m Plaster 0.65 m Mortar -The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar -The distance between the next vertical bar after the first one is 40 cm. -Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height Vertical & Horizontal Rebar Distance Ilustration 2 0.40 m 0.16 m Support Vertical Rebar Lintel Beam Column Rebar 0.65 m 0.65 m 0.65 m 0.65 m Horizontal Rebar -The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar -The distance between the next vertical bar after the first one is 40 cm. -Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height -Added Lintel Beam and support For Window Opening Window Opening Ilustration 0.4 0m 0.4 0m Vertical Rebar Stirrups 0m 0.4 Horizontal Rebar 0m 0.4 -The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar -The distance between the next vertical bar after the first one is 40 cm. -Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height -on the intersection between double wall stirrup is added for extra rigidity. -the stirrup is added on top of every single brick at intercection Intersecting of double wall Ilustration 0.40 m Horizontal Rebar 0.40 m U-Bar 0.40 m Vertical Rebar 0.65 m -The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar -The distance between the next vertical bar after the first one is 40 cm. -Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height -on the intersection between single wall U-Bar is added for extra rigidity. -the U-Bar is added on top of every single brick at intersection Intersecting of single wall Ilustration Lintel Beam Lintel Beam -The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar -The distance between the next vertical bar after the first one is 40 cm. -Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height -on large opening Lintel beam is added for extra rigidity. -the lintel beam is added between two columns where the large openings located Large Door/Window Opening Ilustration Support 0.40 m Lintel Beam -The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar -The distance between the next vertical bar after the first one is 40 cm. -Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height -on door opening Lintel beam is added for extra rigidity. Door Opening