Ilustration 1
Column Rebar
Rockwool
Column Sleeve
polystyrene plates
0.16 m
0.40 m 0.40 m 0.40 m 0.40 m 0.40 m
Vertical
Reinforcement
Horizontal
Reinforcement
0.65 m
Plaster
0.65 m
Mortar
-The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar
-The distance between the next vertical bar after the first one is 40 cm.
-Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height
Vertical & Horizontal Rebar
Distance
Ilustration 2
0.40 m
0.16 m
Support
Vertical Rebar
Lintel Beam
Column Rebar
0.65 m
0.65 m
0.65 m
0.65 m
Horizontal Rebar
-The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar
-The distance between the next vertical bar after the first one is 40 cm.
-Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height
-Added Lintel Beam and support For Window Opening
Window Opening
Ilustration
0.4
0m
0.4
0m
Vertical Rebar
Stirrups
0m
0.4
Horizontal
Rebar
0m
0.4
-The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar
-The distance between the next vertical bar after the first one is 40 cm.
-Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height
-on the intersection between double wall stirrup is added for extra rigidity.
-the stirrup is added on top of every single brick at intercection
Intersecting of double wall
Ilustration
0.40
m
Horizontal
Rebar
0.40
m
U-Bar
0.40
m
Vertical
Rebar
0.65 m
-The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar
-The distance between the next vertical bar after the first one is 40 cm.
-Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height
-on the intersection between single wall U-Bar is added for extra rigidity.
-the U-Bar is added on top of every single brick at intersection
Intersecting of single wall
Ilustration
Lintel Beam
Lintel Beam
-The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar
-The distance between the next vertical bar after the first one is 40 cm.
-Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height
-on large opening Lintel beam is added for extra rigidity.
-the lintel beam is added between two columns where the large openings located
Large Door/Window Opening
Ilustration
Support
0.40 m
Lintel Beam
-The distance for the first vertical rebar of the concrete hollow block is 16 cm away from the outermost of column rebar
-The distance between the next vertical bar after the first one is 40 cm.
-Distance for the Horizontal bar is 65 cm or equal to 3 concrete block height
-on door opening Lintel beam is added for extra rigidity.
Door Opening