Simple Absorber water 4.2 x 10-2 kgmol/s • A tower is to be designed to absorb SO2 from air at 293 K and 1.013 x 105 Pa abs pressure by using pure water. The inert air flow is 6.53 x 10-4 kgmol air/s and the inert water flow is 4.2 x 10-2 kgmol water/s. The entering gas contains 20 mol % SO2 and leaving below 0.1 mol %. Determine the flow rate and composition of the gas and liquid leaving the tower and the required number of equilibrium stages. • (Example 10.7-1, Christie John Geankoplis C.J. Transport Processes and Separation Process Principles (Includes Unit Operations). 4th Ed., 2003: 681-684). Air = 6.53 x 10-4 kgmol/s SO2 = 1.6325 x 10-4 kgmol/s Split : the heavy phase (the liquid) to the stage selected Split below : for feeds below the bottom of a column with no reboiler