Nokia AirScale System Module — AMOD Installing and
Cabling Manual
This guide is a quick reference for the Nokia AirScale Outdoor Subrack installation.
The Nokia AirScale Outdoor Subrack can be stacked on the floor, mounted on a wall or pole.
Safety precautions
1
Safety
precautions
Before installation
Installation
Prepare the installation
2
Content of delivery
4
Dimensions and weight
7
Installing AMOD on a
pole
3
Tools and equipment
5
Minimum clearances
8
Installing AMOD on a
wall
6
Lifting AMOD
9
Installing AMOD on the
floor
10
Installing AMOD
optional items
11
Installing plug-in units
in AMOD
Cabling
12
Preparing for
cabling
13
Cables routing
14
Cabling
After installation
15
Sealing AMOD
Check the installation
16
Installation checklist
The information in this document applies solely to the hardware/software product (“Product”) specified herein, and only as specified herein.
This document is intended for use by Nokia’s customers (“You”) only, and it might not be used except for the purposes defined in the agreement between You
and Nokia (“Agreement”) under which this document is distributed. No part of this document might be used, copied, reproduced, modified or transmitted in
any form or means without the prior written permission of Nokia. If you have not entered into an Agreement applicable to the Product, or if that Agreement
has expired or has been terminated, You might not use this document in any manner and You are obliged to return it to Nokia and destroy or delete any copies
thereof.
The document has been prepared to be used by professional and properly trained personnel, and You assume full responsibility when using it. Nokia welcome
Your comments as part of the process of continuous development and improvement of the documentation.
This document and its contents are provided as a convenience to You. Any information or statements concerning the suitability, capacity, fitness for purpose
or performance of the Product are given solely on an “as is” and “as available” basis in this document, and Nokia reserves the right to change any such information and statements without notice. Nokia has made all reasonable efforts to ensure that the content of this document is adequate and free of material
errors and omissions, and Nokia will correct errors that You identify in this document. But, Nokia’s total liability for any errors in the document is strictly limited
to the correction of such error(s). Nokia does not warrant that the use of the software in the Product will be uninterrupted or error-free.
NO WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY WARRANTY OF AVAILABILITY, ACCURACY, RELIABILITY, TITLE,
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS MADE IN RELATION TO THE CONTENT OF THIS DOCUMENT. IN NO EVENT
WILL NOKIA BE LIABLE FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES,
SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA THAT MAY ARISE FROM THE USE OF
THIS DOCUMENT OR THE INFORMATION IN IT, EVEN IN THE CASE OF ERRORS IN OR OMISSIONS FROM THIS DOCUMENT OR ITS CONTENT.
This document is Nokia proprietary and confidential information, which might not be distributed or disclosed to any third parties without the prior written
consent of Nokia.
Nokia is a registered trademark of Nokia Corporation. Other product names mentioned in this document might be trademarks of their respective owners, and
they are mentioned for identification purposes only.
Copyright © 2019 Nokia. All rights reserved.
Important Notice on Product Safety
This product might present safety risks due to laser, electricity, heat, and other sources of danger.
Only trained and qualified personnel might install, operate, maintain or otherwise handle this product and only after having carefully read the safety information applicable to this product.
The safety information is provided in the ‘Safety precautions’ section in this document and in the ‘Legal, Safety and Environmental Information’ part of documentation set.
Nokia is continually striving to reduce the adverse environmental effects of its products and services. We would like to encourage you as our customers and
users to join us in working towards a cleaner, safer environment. Please recycle product packaging and follow the recommendations for power use and proper
disposal of our products and their components.
If you should have questions regarding our Environmental Policy or any of the environmental services we offer, please contact us at Nokia for any additional
information.
DN187329643, Issue 01, Approval date: 2019-05-13
Product
Releases
Long Term Evolution
FDD-LTE19
TD LTE
Single RAN
TD-LTE19
SRAN19
NOTE:
For more information on installation and maintenance, go to NOLS > Product Information Center > Documentation Finder > Guide to Nokia Customer Documentation and see ‘Best Practices for Improving Equipment
Protection and Longevity’ document.
!
Notice:
This device has not been authorized in accordance with the requirements of the radio telecommunications terminal equipment directive and might not be put into service until it has been made to
comply.
This device complies with Part 15 of the Federal Communications Commission (FCC) rules. Operation is subject to the following two conditions: (1) this device might not cause harmful interference,
and (2) this device must accept any interference received, including interference that might cause
undesired operation.
The unit should be located out of direct sun exposure and away from areas of potential salt spray.
For indoor installations, comply with the indoor installation recommendations.
-2-
Nokia AirScale System Module — AMOD Installing and Cabling Manual
1 Safety precautions
! Notice:
Electrostatic Discharge (ESD) might damage the plug-in units. Wear an ESD wrist strap or use a corresponding
method when handling the plug-in units. The ESD wrist strap does not work before a rack or a cabinet is earthed
(grounded).
NOTE:
For NEBS requirements, see Nokia AirScale BTS Installation Site Requirements.
Choosing installation site for Nokia AirScale Outdoor Subrack AMOD
! Notice:
Nokia AirScale Outdoor Subrack (AMOD) is intended for installation in outside locations or the equivalent.
For details about choosing an installation site for Nokia AirScale Outdoor Subrack, see Nokia AirScale BTS Installation Site
Requirements.
Disconnecting devices
WARNING! Risk of power supply failure and, in rare cases, of short circuit.
Make sure to connect the polarity of power supply correctly according to the markings on the connectors.
2 Content of delivery
AMOD delivery
Delivery
Nokia AirScale Outdoor
Subrack
Contents
Product code
1 x AMOD Subrack
474930A
1 x AMOD site bag
091111A
Contents
Product code
AMOD site bag delivery
Delivery
1 x GND lug with 2 x M5 holes
Site bag
1 x power connector
2 x DC connector lug
-3-
P476074
P476302
10 x M5 rubber plug
833694A
14 x M4 rubber plug
833693A
5 x M8 rubber plug
834705A
1 x 8 mm triangle Bellcore key
P348553
4 x M5x12 torx (T25) screw
P300057
2 x M5 nut
25 x cable tie
P345283
6401142
1 x Velcro tie
P317154
2 x GND cable
996433A
4 x connection pin
821513A
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
AMOD optional items depended on the configuration
Item
Description
AMFV
3U plinth kit for AMOD
AMFX
Wall mount kit for AMOD
AMFY
Mufflers kit for AMOD
AMFF
Blind panel Assy for AMOB
FPKA
Flexi Pole Mounting
Kit (30-120 mm)
FPKC
Flexi Pole Mounting
Kit (60-300 mm)
AMHB
GPS bracket assembly
FYGM
GPS module
Product code
Delivery Content
2 x 3U plinth bracket
1 x front screen
1 x rear bracket
12 x M4x10 torx (T20) screw
4 x connection pin
6 x M5x12 torx (T25) screw
2 x M5x6 torx (T25) screw
475047A
1 x wall mount bracket
1 x top support bracket
8 x M8x12 socket (13 mm) screw
2 x M8x20 pan head socket (13 mm) screw
475048A
1 x muffler
12 x M4x6 torx (T20) screw
475049A
1 x blank panel for ASIA
5 x blank panel for ABIA
474416A
1 x FPKA Flexi pole mounting kit
2 x aluminum casing
2 x M10x120 hex (8 mm) screw
6 x M8x20 socket (13 mm) screw
2 x bolt restrainer
1 x FPKC bracket 1
1 x FPKC bracket 2
1 x FMFA rodent block plate
2 x M10x315 hex (8 mm) screw
5 x M8x30 socket (13 mm) screw
5 x M8x20 socket (13 mm) screw
5 x M8 nut
8 x M5x12 torx (T25) screw
4 x connection pin
471649A
1 x GPS mount bracket
475066A
1 x GPS module
4 x M3x8 torx (T10) screw
473394A
472821A
3 Tools and equipment
-4-
Torque
screwdriver
Torque
wrench
TORX bit:
T10, T20, T25
Socket
10 mm, 13 mm
Hex key (Allen)
7 mm, 8 mm
Side
cutters
Tape
measure
Level
M8 Eye
bolts
Drill
Cleaning tools for
optical cables
Lifting
bag/bucket
Cable clamping
tool (GND and DC)
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
4 Dimensions and weight
AMOD dimensions and weight
Property
Value
Height
488 mm (19.21 in.)
Width
487 mm (19.17 in.)
Depth
665 mm (26.18 in.)*
Weight
35 kg (77.16 lb)
Volume
158 L
* When using a muffler depth of the subrack is increased by
110 mm (4.33 in.)
5 Minimum clearances
AMOD clearance requirements
Top minimum clearances: 0 mm (0 in.) for stack installation.
Bottom minimum clearances: 133.35 mm (5.25 in.) (3U) for floor and stack installation.
-5-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
6 Lifting AMOD
! Notice:
The AMOD subrack is heavy. Additional personnel or lifting equipment might be needed when the cabinet is moved, unpacked, or
lined up. In addition, follow any local regulations applicable to the
installation.
! Notice:
The AMOD subrack can be lifted using four eye bolts and hoisting
belt or rope attached to the lifting points. Only an empty AMOD
subrack can be lifted.
! Notice:
The AMOD handles can be used only for hand carrying the subrack. Do not lift AMOD using the handles.
7 Installing AMOD on a pole
Tools and items required for installation
Item
Description
Quantity
Product code
AMFX
Wall mount kit for AMOD
1
475048A
FPKA/FPKC
Flexi Pole Mounting
Kit (30-120 mm)/(60-300 mm)
3
471649A/472821A
Torque wrench
-
1
-
Socket
13 mm
1
-
Hex key (Allen)
8 mm
1
-
AMFX mount kit on pole installation using FPKA
1. Fix the upper FPKA on the pole.
2. Tighten two M10 screws to the 30 Nm (22.13 ft-lb).
3. Fix two M8x20 screws.
-6-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
4. Fix and tighten to 20 Nm (14.75 ft-lb) the middle and the lower FPKA bracket with AMFX
using eight M8x20 screws.
5. Hang the AMFX mount kit on the upper FPKA pole mounting kit.
6. Tighten four M8x20 screws to 20 Nm (14.75 ft-lb).
7. Tighten four M10 screws to the 30 Nm (22.13 ft-lb) on the middle and lower FPKA
bracket.
8. Lift and mount AMOD on the AMFX mount kit.
9. Tighten AMOD with AMFX mount kit to 20 Nm (14.75 ft-lb) using six M8x12 screws.
10. Tighten the top support bracket to 20 Nm (14.75 ft-lb) using two M8x12 screws and
two M8x20 screws.
AMFX mount kit on pole installation using FPKC
There are four different lengths of the screw available and four places for the
screw in the FPKC. When attaching the FPKC to the pole, use the shortest
possible bolts and the holes which distance is the closest to the pole diameter.
Cut Location
Slot 1
Slot 2
Slot 3
Slot 4
Cut 1
60-100 mm
101-140 mm
N/A
N/A
Cut 2
141-180 mm
181-220 mm
221-260 mm
N/A
No cut
N/A
N/A
N/A
261-300 mm
1. Insert two M10 screws and fix FPKC on
the pole.
-7-
2. Tighten two M10 screws to the 30 Nm
(22.13 ft-lb).
3. Fix two M8x20 screws.
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
4. Fix and tighten to 20 Nm (14.75 ft-lb) the middle and the lower FPKC bracket with AMFX
using eight M8x20 screws.
5. Hang the AMFX mount kit on the upper FPKC pole mounting kit.
6. Tighten four M8x20 screws to 20 Nm (14.75 ft-lb).
7. Tighten four M10 screws to the 30 Nm (22.13 ft-lb) on the middle and lower FPKC bracket.
8. Lift and mount AMOD on the AMFX mount kit.
9. Tighten AMOD with AMFX mount kit to 20 Nm (14.75 ft-lb) using six M8x12 screws.
10. Tighten the top support bracket to 20 Nm (14.75 ft-lb) using two M8x12 screws and two
M8x20 screws.
8 Installing AMOD on a wall
Tools and items required for installation
Item
Description
Quantity
Product code
AMFX
Wall mount kit for AMOD
1
475048A
Torque wrench
-
1
-
Socket
13 mm
1
-
Drill
-
1
-
Wall mounting HW
Proper for wall material (M8)
8
-
Level
-
1
-
Tape measure
-
1
-
NOTE:
Torque values and tools for wall mounting hardware need to be specified by wall mounting hardware manufacturer. Tool
and screw type for wall mounting hardware showed in this procedure serve as an example only.
-8-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
AMFX mount kit on wall installation
1. Mark the mounting screw locations on the wall and drill the holes.
2. Install the anchoring bolts in all holes (instructions can vary depending on anchoring
bolts used):
a) Slightly fasten the expansion bolt and insert the bolt vertically into the hole.
b) Hit the expansion bolt with a rubber hammer until the expansion sleeve is fully embedded.
c) Fasten the expansion bolt clockwise until the expansion sleeve is fixed securely into the
floor.
d) Loosen the bolt counter-clockwise, and successively remove the M8 nut, the spring
washer, the plastic sleeve, and the flat washer. Discard the plastic sleeve.
3. Lift the AMFX mounting kit on the wall and hang it on the anchoring bolts.
4. Tighten twelve M8 nuts to the torque value specified by wall mounting hardware manufacturer.
5. Lift and mount AMOD on the AMFX mount kit.
6 Tighten AMOD with AMFX mount kit to 20 Nm (14.75 ft-lb) using six M8x12 screws.
7. Tighten the top support bracket to 20 Nm (14.75 ft-lb) using two M8x12 and two M8x20
screws.
9 Installing AMOD on the floor
Tools and items required for installation
Item
Description
Quantity
Product code
AMFV
3U plinth kit for AMOD
1
475047A
Torque wrench
-
1
-
Torque screwdriver
-
1
-
TORX bit
T25, T20
2
-
Floor mounting HW *
Proper for floor material (M12)
6
-
Level *
-
1
-
Tape measure *
-
1
-
Drill *
Percussion drill bit
1
-
* Not needed when AMOD is not installed directly on the floor
-9-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
NOTE:
Torque values and tools for floor mounting hardware need to be specified by floor mounting hardware manufacturer. Tools and screw
type for floor mounting hardware showed in this procedure serve as an example only.
AMFV plinth installation
NOTE:
AMFV plinth is mandatory in floor and stack installation cases.
1. Fix 3U side brackets using six M5x12 screws.
2. Tighten six M5 screws to 4.3 Nm (38.1 in-lb).
3. Fix and tighten the front screen and rear bracket to 2.2 Nm
(19.47 in-lb) using twelve M4x10 screws.
TIP:
A long screwdriver or screwdriver with an extension is recommended for tightening M5 screws. Insert a T25 screwdriver
through the six M12 holes on the bottom of the AMFV plinth and
tighten the M5 screws.
Floor installation
NOTE:
AMFV plinth needs to be installed before floor installation. Installing AMOD to the AMFV plinth after fixing plinth to the floor is not
possible.
1. Mark the mounting holes location on the floor and drill holes for anchoring bolts.
2. Install the anchoring bolts (instructions can vary depending on anchoring bolts used):
a) Slightly fasten the expansion bolt and insert the bolt vertically into the hole.
b) Hit the expansion bolt with a rubber hammer until the expansion sleeve is fully embedded.
c) Fasten the expansion bolt clockwise until the expansion sleeve is fixed securely into the floor.
d) Loosen the bolt counter-clockwise, and successively remove the M8 nut, the spring washer, the plastic sleeve, and the flat washer.
Discard the plastic sleeve.
3. Tighten the M12 anchoring bolts to the value specified by floor mounting hardware manufacturer..
-10-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
Stacking units on the AMOD
NOTE:
AMOD can be installed on a floor in a stack up to maximum height of 22U (1U-44,45
mm). Maximum allowed configuration with AMOD subrack is 1 x AMOD and up to 3 x 3U
modules. AMOD stack configurations meet Earthquake Zone 2 requirements. Only standalone AMOD installed on the floor meets earthquake requirement for Zone 4.
NOTE:
3U modules installed on top of the AMOD subrack need to comply with the standard
ETSI EN 300 019-2-4 Class 4M5.
NOTE:
Installation of empty EMHH or EMHA 3U casing is not allowed in floor assembly.
1. Fix and tighten four M5 connection pins to 4.3 Nm (38.1 in-lb)
2. Align the holes on the bottom side of the module with the four connection pins on the
AMOD.
3. Push the module back until it stops.
4. Tighten the module to 4.3 Nm (38.1 in-lb) using two M5 screws.
Stacking AMOD on the units
NOTE:
AMOD can be installed on a floor in a stack up to maximum height of 22U (1U-44,45 mm).
Maximum allowed configuration with AMOD subrack is 1 x AMOD and up to 3 x 3U modules. AMOD stack configurations meet Earthquake Zone 2 requirements.
NOTE:
3U modules installed under the AMOD subrack need to comply with the standard
ETSI EN 300 019-2-4 Class 4M5.
NOTE:
Installation of empty EMHH or EMHA 3U casing is not allowed in floor assembly.
1. Align the holes on the AMOD plinth with the four connection pins on the module.
2. Push AMOD back until it stops.
3. Tighten AMOD to 4.3 Nm (38.1 in-lb) using two M5x6 screws.
-11-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
10 Installing AMOD optional items
AMFY muffler kit tools and items required for installation
Item
Description
Quantity
Product code
AMFY
Muffler kit for AMOD
1
475049A
Torque screwdriver
-
1
-
TORX bit
T20
1
-
AMFY muffler kit installation
1. Fix the muffler using twelve M4x6 screws.
2. Tighten twelve M4x6 to 2.2 Nm (19.47 in-lb).
AYGA/FYGM GPS module tools and items required for installation
Item
Description
Quantity
Product code
AYGA/FYGM
GPS module
1
474129A/473394A
AMHB
GPS bracket
1
475066A
Torque screwdriver
-
1
-
TORX bit
T20
1
-
Tie
-
2
-
Side cutters
-
1
-
-12-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
AYGA/FYGM GPS module installation
1. Insert a triangle Bellcore key and turn it counterclockwise.
2. Open the AMOD door.
3. Fix the FYGM module to the AMHB bracket using four M3x8 screws and tighten the screws to 0.8 Nm (7.08 in-lb).
4. Fix the GPS module with a bracket inside AMOD.
5. Tighten two M4 screws to 2.2 Nm (19.47 in-lb)
11 Installing plug-in units in AMOD
Tools and items required for installation
Description
Quantity
Product code
Common unit
2*
473095A/474403A
ABIA
Capacity unit
6*
473096A
ASIB/ASIBA
Common unit
2*
473764A/474408A
ASIK/ASIKA
Common unit
2*
474021A/474424A
ABIL
Capacity unit
6*
474020A
AMFF
Blind panel
1
474416A
Torque screwdriver
-
1
-
TORX bit
T10
1
-
Item
ASIA/ASIAA
* Plug-in units quantity and type depend on the configuration.
-13-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
Plug-in units supported technology
Description
Technology
Product code
Common unit
LTE
473095A/474403A
ABIA
Capacity unit
LTE
473096A
ASIB/ASIBA
Common unit
LTE
473764A/474408A
ASIK/ASIKA
Common unit
5G
474021A/ 474424A
ABIL
Capacity unit
5G
474020A
Item
ASIA/ASIAA
Plug-in units installation
Minimum configuration of AMOD subrack is one common unit and one capacity unit. Maximum configuration of AMOD subrack is
two common units and six capacity units.
! Notice:
Electrostatic Discharge (ESD) might damage the plug-in units. Wear an ESD
wrist strap or use a corresponding method when handling the plug-in units.
NOTE:
ASIAA, ASIBA and ASIKA are a customer-specific variants of common units. ASIAA,
ASIBA and ASIKA follow the same installation rules as ASIA, ASIB and ASIK except
for the DC connector, for more information see ‘Connecting the DC power cables’.
! Notice:
Be careful while handling the plug-in units. A proper way of holding common
and capacity plug-in units is presented on the graphic.
NOTE:
Graphics serve as an example only. The plug-in units need to be inserted after
AMOD subrack is already installed and fixed on the site.
1. Insert a triangle Bellcore key and turn it counterclockwise.
2. Open the AMOD door.
3. Open the common plug-in unit extractors.
-14-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
! Notice:
Be careful
while handling plug-in
units. Avoid any mechanical impact to
the visible components. Insert plug-in
units slowly to their slots.
4. Carefully insert the common plug-in unit
into the AMOD subrack and close the
extractors on both sides.
5. Tighten the two screws by hand, then
tighten to 1 Nm (8.9 in-lb).
6. Carefully insert the capacity plug-in unit
into AMOD subrack.
7. Tighten the two screws by hand, then
tighten to 1 Nm (8.9 in-lb).
8. For each consecutive common plug-in
unit repeat steps 3 to 5. For capacity plugin unit repeat steps 6 and 7.
NOTE:
The slots C1 and C2 are dedicated for common plug-in units, the slots B1 to B6 are
dedicated for capacity plug-in units.
B3
B6
B2
B5
B1
B4
C1
C2
NOTE:
Capacity plug-in units should be inserted in the lower slots first and then in the higher
slots.
NOTE:
AMOD is delivered without dummy panels. Install the dummy panels (AMFF 474416A)
in the slots which are not used for the installation. Tighten the screws on the dummy
panels to 1 Nm (8.9 in-lb). The remaining dummy panels should be stored in case they
need to be installed to AMOD if any plug-in units are removed at any point from AMOD.
Make sure that no slots remain empty.
NOTE:
It is possible to have two separate logical BTSs, one in each half-subrack. In such
case ensure that you install the respective common and capacity plug-in units
on the same side (left or right) of the subrack.
Example:
5G-LTE subrack sharing in the minimum
configuration
Dummy panel Dummy panel
Dummy panel Dummy panel
Result:
The common and capacity plug-in units installed inside AMOD.
-15-
ABIA (LTE)
ABIL (5G)
ASIA (LTE)
ASIK (5G)
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
12 Preparing for cabling
Tools and items required
Description
Quantity
Product code
GND cable
Common unit grounding
2*
996433A
GND lug
GND lug with 2xM5 holes
2* (only 1 in AMOD site bag)
P476074
M5x12 torx (T25) screw
AMOD and plinth grounding
4*
P300057
M5 nut
Common unit grounding
2*
P345283
TORX bit
T25
1
-
Torque wrench
-
1
-
Socket
10 mm
1
-
Cable clamping tool
-
1
-
Item
* Needed quantity depends on installation and configuration variant. Quantity in the table covers maximum configuration and a
plinth installed.
Connecting the main grounding cable
NOTE:
When AMOD is installed with AMFV 3U plinth, both plinth and
subrack need to be grounded to the main grounding point.
1. Strip the ending of the main GND cable exposing 22 mm (7/8
in.).
2. Crimp the lug onto GND wire.
NOTE:
When AMOD is installed on the AMFV 3U plinth, second GND lug is
required. 3U plinth support lug with 2 x M5 holes (distance
between holes is 16 mm (5/8 in.) or one M8 hole. GND lug for
AMFV plinth is not part of the delivery.
3.Slide the heat shrink over the lug barrel.
NOTE:
Use a heat gun to evenly apply heat over the length and around
the tubing beginning from one end to the other until it is uniformly shrunken. Allow the tubing to cool down slowly before applying
physical stress to it.
4. Fix and tighten the grounding cable to the 4.3 Nm (38 in-lb)
when using two M5 screws or to the 8-10 Nm (5.9-7.4 ft-lb) when
using M8 screw.
NOTE:
Grounding points for the main grounding cable are on the both
sides of AMOD and AMFV 3U plinth. Connect the grounding cable
to the
preferred side.
NOTE:
M8 screw is not a part of the delivery.
-16-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
Grounding common plug-in unit
1. Unscrew the screws from each grounding point of common plug-in unit using the
TX25 screwdriver.
2. Place the grounding cable (AMOD site bag: 996433A) lug above the thread of the
grounding point and insert two M5x12 screws for each common plug-in unit. Tighten
screws to 4.3 Nm (38.1 in-lb) using the TX25 screwdriver.
3. Connect the other end of the grounding cable to the grounding point on the AMOD
subrack. Tighten M5 nut (AMOD site bag: P345283) to 4.3 Nm (38.1 in-lb) using 10 mm
socket.
NOTE:
Common plug-in unit installed on the right side of the AMOD subrack needs to be
grounded to the same GND point on the right side of AMOD.
Grounding FYGM GPS module
1. Fix and tighten the grounding cable to
4.3 Nm (38 in-lb) when using two M5 screws
or to the 8-10 Nm (5.9-7.4 ft-lb) when using
M8 screw.
2. Connect the other end of the grounding
cable to the grounding point on the AMOD
subrack. Tighten M5 nut to 4.3 Nm (38.1 inlb) using 10 mm socket.
13 Cables routing
Tools and items required
Description
Quantity
Product code
Torque screwdriver
-
1
-
TORX bit
T25
1
-
Item
-17-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
DC cables routing
NOTE:
DC cable entries are located on both sides of the AMOD subrack. Choose the left cable entry for connecting the left half of the
AMOD subrack and the right cable entry for connecting the right half of the AMOD subrack.
1. Unscrew two M5 screws on the press bar and disassemble the plugs, press bar and sealing rubber.
2. Route the cables through the cable entry from the bottom and put the cables in the sealing rubber holes one by one.
3. Insert the sealing rubber into the cable entry and tighten the press bar to 4.3 Nm (38.1 in-lb). For all unused holes in the cable
entry insert the plugs.
NOTE:
The press bar should be tightened after all cables are connected as instructed in the ‘Cabling’ section.
NOTE:
If all of the cable entry slots have been used, store away plugs for future use.
Cables routing
NOTE:
Cable entries are located on both sides of the AMOD subrack. Choose the left cable entry for connecting the left half of the AMOD
subrack and the right cable entry for connecting the right half of the AMOD subrack.
1. Unscrew two M5 screws on the press bar and disassemble the plugs, press bar and sealing rubber.
2. Route the cables through the cable entry from the bottom and put the cables in the sealing rubber holes one by one.
NOTE:
Start routing the cables from the upper cable entry slots.
3. Insert the sealing rubber into the cable entry and tighten the press bar to
4.3 Nm (38.1 in-lb). For all unused holes in the cable entry insert the plugs.
NOTE:
The press bar should be tightened after all cables are connected as
instructed in the ‘Cabling’ section.
NOTE:
If all cable entry slots are used, store away plugs for future use.
-18-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
14 Cabling
Tools and items required
Description
Quantity
Product code
Torque screwdriver
-
1
-
TORX bit
T25
1
-
Cable clamping tool
-
1
-
Power connector
AMOD site bag
1
P476302
DC connector lug
AMOD site bag
2
-
Item
Connecting the main power cable to the AMOD PDU unit
WARNING! Risk of short circuit.
Make sure that power is not applied to the system before you connect the DC power cable.
WARNING! Risk of power supply failure and, in rare cases, of short circuit.
Make sure to connect the polarity of power supply correctly according to the markings on the connectors.
1. Strip each 4 AWG (21 mm²) cable exposing 18 mm (0.7 in.) of bare wire.
2. Put the DC connector lug on each cable.
3. Crimp the lugs onto each wire.
4. Insert each wire into the DC power connector (P476302).
5. Connect the main power cable to the
AMOD PDU power unit.
Connecting the power cable (common plug-in unit with clamped DC input)
1. Strip the ending of the DC power cable(s).
Select from the available options:
1a. For a single-sheathed DC cable, strip 4 cm (1.6 in.) of the DC power cable braiding and
18 ± 1 mm (0.7 in.) of the wires' insulation using the cable stripper.
1b. For two individual DC cables, strip 18 ± 1 mm (0.7 in.) of the wires' insulation using
the cable stripper.
NOTE:
Stripping DC power cables is mandatory when common plug-in unit, installed in the right
half of the AMOD subrack, is powered separately for load-balancing between the two
inputs through a DC bridge in the subrack’s rear.
-19-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
2. Lift the latch of the DC power cable input.
3. Insert the PDU DC power cable into the DC power cable input of the common plug-in unit. Push the DC power cable until it stops
in the DC terminal. Make sure there are no stray conductor strands. Close the latch of the DC power input so that the DC power
cable is firmly secured. Make sure the latch is fully closed by pushing it downwards.
4. Repeat step 3 for the second DC cable.
5. If independent DC feeding is used for second common plug-in unit, repeat steps 1 - 4 with the second DC power cable.
Connecting the power cable (common plug-in unit with lug DC input)
1. Strip each DC cable exposing 22 mm (7/8 in.) of bare wire.
NOTE:
Striping the DC power cables is mandatory when common plug-in unit, installed in
the right half of AMOD subrack, is powered separately for load balancing between
the two inputs through a DC bridge in the subrack’s rear.
2. Crimp the lug onto each wire.
3. Slide the heat shrink over the lug barrel.
NOTE:
Use a heat gun to evenly apply heat over the length and around the tubing beginning from one end to the other until it is uniformly shrunken. Allow the tubing to
cool down slowly before applying physical stress to it.
4. Lift the latch of the DC power cable input.
5. Install the RTN (0 V) cable with the lug onto the terminal Block labeled RTN (+) on
the left side of the terminal block. Mount the lug to the terminal using the captive
screw provided with the common plug-in unit and torque the screw to 4.3 Nm (38.1
in-lb).
6. Install the Supply (-48 V) cable with the lug onto the terminal Block labeled ‘PWR’
(-) on the right side of the terminal block. Mount the lug to the terminal using the
captive screw provided with the common plug-in unit and torque the screw to 4.3
Nm (38.1 in-lb).
7. Close the latch of the DC power input.
8. If independent DC feeding is used repeat steps 1-7 for the second common
plug-in unit.
NOTE:
The power cable pair must be strain-relieved (using tie wraps or wax cord) to protect from mechanical stress.
-20-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
Common plug-in units interfaces
NOTE:
For more information on interfaces, see the ‘Nokia AirScale System Module Product Description’ document.
NOTE:
SFP, QSFP, EAC, synchronization, transmission, LMP, optical and system module extension cables are not part of the delivery.
Before starting the cabling, get familiar with the common plug-in units interfaces.
NOTE:
Connect only the cables that are required for your configuration.
NOTE:
Do not remove dust plugs from unused ports.
Connecting the EAC and synchronization cables
1. Insert the HDMI cables into the EAC, Sin, and Sout ports of the common plug-in unit.
2. Repeat for the second common plug-in unit, if used.
Connecting the transmission cables (LTE only)
1. Insert the RJ-45 into the RJ-45 input of the common plug-in unit and make sure it clicks into place.
2. Repeat for the second common plug-in unit, if used.
-21-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
Connecting the LMP cables
1. Insert the RJ-45 cable into the RJ-45 input of the common plug-in unit and make sure RJ-45 cable clicks into place.
2. Repeat for the second common plug-in unit, if used.
Connecting the system extension cables in ASIA
1. Insert the Mini SAS cable into the SEI1, and SEI2 ports of the ASIA plug-in unit and make sure Mini SAS cable clicks into place.
2. Repeat for the second ASIA, if used.
NOTE:
System Module Extension Interfaces in ASIA Common plug-in unit have MiniSAS-HD connectors. In other types of common plugin units this interface has QSFP+ connectors.
Preparing optical interfaces
NOTE:
The SFPs and QSFPs are to be inserted after the AMOD subrack
is installed on the floor, pole or wall.
TIP:
Make sure that there is no dust or other obstacles inside the
SFP/QSFP port before inserting SFP/QSFP.
NOTE:
Do not remove the dust caps from the unused SFP/QSFP ports.
1. Locate all optical interfaces on common and capacity plug-in
units
2. Insert the SFP/QSFP to each optical interface and push in
until it clicks.
3. Repeat for all required ports.
-22-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
Connecting the optical cables
! Notice:
Optical cables are fragile. Overbending the optical cables damages the cables and can detach or damage the connectors. Do not bend optical cables beyond the minimum radius of:
- 70 mm (2.7 in.), when cable diameter is 7 mm (0.3 in.)
- 50 mm (2.0 in.), when cable diameter is 5 mm (0.2 in.).
WARNING! Danger of eye damage caused by invisible laser beam.
Make sure that the laser beam is switched off during optical fiber installation.
! Notice:
Make sure that the optical cable connectors are clean.
NOTE:
Some optical cables are pre-bent, make sure to route them in the respective direction.
1. Insert the optical cable into the respective SFP/QSFP on the common or the capacity plug-in unit.
2. Repeat for all required ports.
SFP
QSFP
Manage cables
TIP:
All cables for one plug-in unit can be tied together with a cable tie, so each plug-in unit has an independent cable group. Necessary
cables and plug-in units can be easily replaced or removed using this method. Fix each plug-in unit cable group to the fixing plate
on the top right or left side of the AMOD subrack.
Cables routed outside the AMOD subrack can be tied together in groups. Cable groups can be tied to the plinth on the left or the right side of the AMOD
subrack.
! NOTICE:
Attaching cables to the front inlet is forbidden. Attaching cables to the
front inlet may block or reduce airflow.
NOTE:
Make sure that static bending radius of fiber cables is no more than 10D
(D - bending area outer diameter).
-23-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
15 Sealing AMOD
Tools and items required
Description
Quantity
Product code
M5 rubber plug
AMOD site bag
*
833694A
M4 rubber plug
AMOD site bag
*
833693A
M8 rubber plug
AMOD site bag
*
834705A
Item
* Quantity needed depends on installation variant.
Rubber plugs installation
Rubber plugs need to be inserted in all unused holes in AMOD subrack to ensure proper IP protection. The number of holes depends
on the installation variant.
NOTE:
Graphics show all holes where rubber plugs can be inserted.
-24-
GO TO
FIRST PAGE
Nokia AirScale System Module — AMOD Installing and Cabling Manual
16 Installation checklist
Perform these checks to make sure that the installation is complete:
Delivery is complete and undamaged.
Minimum clearances are met.
All mounting screws are tightened to the specified torque.
Cables do not violate specified bending radius.
AMOD subrack is securely fixed to the pole, wall or floor.
AMOD subrack is installed according to instructions.
AMOD subrack is stacked according to instructions.
Common plug-in unit(s) is/are installed in a desired configuration according to instructions.
Capacity plug-in unit(s) is/are installed in a desired configuration according to instructions.
Common plug-in unit(s) is/are grounded to the AMOD subrack.
All slots on AMOD subrack have either a plug-in unit or a dummy panel installed and there are no empty slots.
GND cables are connected.
DC power cable is connected.
EAC and synchronization cables are connected.
Transmission cables are connected.
SFPs/QSFPs are inserted into optical ports (amount depends on the need).
Optical cables are connected to common plug-in unit(s).
Optical cables are connected to capacity plug-in unit(s).
Cables are tied properly according to instructions.
Rubber plugs are installed according to instructions and there are no empty holes.
Site is clean and installation is complete.
-25-