Release Note
Release Notes
( 9701-VWSx ) FactoryTalk View® Site Edition is a supervisory HMI software package
for enterprise solutions. [FTView, FTViewSE
Version 13.00.00 (released 3/2022)
Catalog Number FactoryTalk View Site Edition
These release notes describe version information for FactoryTalk View Site Edition, version 13.00.00 (released
3/2022).
Requirements
The following are the system requirements for FactoryTalk View SE version 13.00.00.
Hardware requirements
The following is a sample specification of computer hardware to run FactoryTalk View SE applications aligned
with the hardware used in product development testing.
Type
Operator Workstation
Description
FactoryTalk View SE Client
CPU
RAM
Intel® Core™ i5 Standard
Power processor
4 GB
Intel Core i5 Standard Power
processor
8 GB
FactoryTalk Linx
Studio 5000
FactoryTalk View SE server
Smaller systems:
or
Engineering Workstation
Application Server
FactoryTalk View SE Station
FactoryTalk View Studio Enterprise
Intel Core i5 Standard Power
processor
FactoryTalk Alarms and Events tag- Medium to larger systems:
based server
Quad core Intel Core Xeon
FactoryTalk Linx data server with
family processor
FactoryTalk Alarms and Events
enabled
Site Feedback
This release has the following requirements.
4 GB
FactoryTalk View Studio Enterprise
8 GB
Software requirements
Operating systems
FactoryTalk View SE is tested on the following operating systems:
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
1/18
7/19/23, 3:35 PM
Release Note
Windows® 10* (v2004, v20H2, v21H1, and v21H2)
Windows 10 IoT Enterprise 2016 Long-Term Servicing Branch (LTSB)
Windows 10 IoT Enterprise 2016 (LTSB) Embedded**
Windows 10 IoT Enterprise 2019 Long-Term Servicing Channel (LTSC)
Windows 11
Windows Server® 2012
Windows Server 2012 R2
Windows Server 2016*
Windows Server 2019
* For more information, see Rockwell Automation Knowledgebase Document ID: IN4493 - Windows 10 Support
for the FactoryTalk Suite of Rockwell Software products
(https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/964391) and IN4718 - Windows Server
2016 Support for the FactoryTalk Suite of Rockwell Software products
(https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/991031).
** This operating system is supported with the Allen-Bradley® 61xx family of industrial computers and
CompactLogix™ 5480 family of controllers.
Domain controller requirements
Windows Server 2012
Windows Server 2012 R2
Windows Server 2016
Windows Server 2019
Site Feedback
The following operating systems are supported for use as domain controllers for FactoryTalk View SE client
computers. Using a domain is recommended for applications that include more than 10 computers. If your
application includes 10 or fewer computers, they can be organized in a workgroup.
Rockwell Automation Test Environment
Rockwell Automation tests software products under a standard configuration of operating systems and antivirus
software. For additional information, see the Knowledgebase Document ID: PN24 - Rockwell Software Products
and Antivirus Software (https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/35330).
Supported browsers
The following web browsers have been tested and are supported for use with this release:
Google® Chrome™ browser
Microsoft® Edge™
Mozilla® Firefox®
Security requirements
To help meet secure system design requirements, review these publications:
Configure System Security Features User Manual
(https://literature.rockwellautomation.com/idc/groups/literature/documents/um/secure-um001_-en-p.pdf)
(publication SECURE-UM001)
System Security Design Guidelines
(https://literature.rockwellautomation.com/idc/groups/literature/documents/rm/secure-rm001_-en-p.pdf)
(publication SECURE-RM001)
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
2/18
7/19/23, 3:35 PM
Release Note
Converged Plantwide Ethernet (CPwE) Design and Implementation Guide
(https://literature.rockwellautomation.com/idc/groups/literature/documents/td/enet-td001_-en-p.pdf)
(publication ENET-TD001)
To learn about implementing CIP Security, see CIP Security with Rockwell Automation Products
(https://literature.rockwellautomation.com/idc/groups/literature/documents/at/secure-at001_-en-p.pdf) (publication
SECURE-AT001).
Features
This release includes the following system features.
FactoryTalk View SE version 13.00.00 has the following new and enhanced features.
New features
Site Feedback
XY Plot object
XY Plot is a specific type of trend that plots one set of tag values versus another set of tag values, which
shows the relationship between two sets of data over time.
.NET Control object
.NET Control supports reusable and custom Windows Forms and WPF controls, which can be used in
FactoryTalk View applications for their property, method, and event functions.
New data grid data source: data log model
Data grid supports data log models stored in file sets as a new data source, displaying data log information
in a tabular format.
Synchronization of HMI tag values in a redundant system
FactoryTalk View SE adds an option that automatically synchronizes the HMI memory tag values between
the active and standby HMI servers.
Client-specific tags for network applications
Client tags are memory tags specific to each client and user session in a distributed system. Client tags
support client-specific behavior, such as animation, object visibility, or custom navigation menus.
FactoryTalk System Status Portal
A new webpage that provides an overview of all FactoryTalk application servers and their statuses,
including HMI servers, FactoryTalk Alarms and Events servers, and data servers. This portal is installed
with FactoryTalk Services Platform by customized installation.
FactoryTalk Batch View HMI controls
FactoryTalk Batch View HMI controls are included in the FactoryTalk View installation, including
BatchesList, PromptsList, SFC, and FullView.
Enhanced features
HMI tag access for server-side scripts
FactoryTalk View SE supports bi-directional interactions with data using PowerShell scripts.
TrendPro enhancements:
Show a tag's caption instead of tag name when hovering over a line in the chart.
Configure whether to allow panning the data by moving the mouse.
Support extended tag properties for tag caption and engineering unit.
Introduce a new VBA property that sets whether the custom file explorer or Windows file explorer
opens when saving the trace data or captured image.
Introduce new VBA properties to support single trace and stack axes modes.
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
3/18
Release Note
Chromium-based web browser
The Web Browser object supports Microsoft Edge (based on Chromium) as the rendering engine in
addition to Internet Explorer.
Automatic Diagnostics functions
The Automatic Diagnostics functions retrieve information of automatic diagnostic events from one or
multiple devices.
Extra alarm and event functions
The extra FactoryTalk alarm and event functions retrieve information of FactoryTalk alarms in four
priorities, urgent, high, medium, and low.
Language switching in TrendPro and RecipePro
TrendPro and RecipePro support language switching.
E-Signature tab of a multistate push button
The multistate push button object adds one tab to configure electronic signature.
Custom message for electronic signature
FactoryTalk View SE adds an option to configure a customized diagnostic audit message for electronic
signature.
String input enhancement
String input adds the Remark option to configure a customized diagnostic audit message for when
downloading a new tag value at runtime.
PlantPAx Library of Process Objects
Visualization files of PlantPAx Library of Process Objects V5.00.02 are included in the FactoryTalk View
installation. You can import them to newly created or existing HMI projects.
Cross Reference enhancement
The Cross Reference form adds the function to search object names.
Horizontal or vertical position animation available for more objects
FactoryTalk View SE expands horizontal or vertical position animation for more objects, such as images
and panels.
Login and Logout commands
In a multi-monitor deployment, instead of opening on the main monitor, Login and Logout dialog boxes
open on the monitor where the Login and Logout commands are called from.
Application Documenter
Application Documenter supports the export of application information with commands.
Accepted and Rejected events
The button, numeric input, and string input objects contain the Accepted and Rejected events in VBA for
the electronic signature function.
Site Feedback
7/19/23, 3:35 PM
Corrected Anomalies in This Release
This release corrects the following anomalies.
The following list identifies the anomalies corrected in FactoryTalk View SE version 13.00.00.
In certain cases, Tag Browser may not respond when selecting a tag. First reported in version 10.00.00.
[Jira 1096077]
After clicking a button very quickly multiple times to switch between displays, the display client stops
responding. First reported in version 8.00.00. [Jira 1068394]
If data logging is configured to purge the oldest records at midnight, data logging stops when the records
are being deleted. First reported in version 12.00.00. [Jira 1388792]
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
4/18
7/19/23, 3:35 PM
Release Note
Site Feedback
Running global object compilation cannot compile all the displays and global objects due to the comma (,)
used in the display name. First reported in version 12.00.00. [Jira 1336540]
The percentage sign (%) disappears in the caption of a multistate indicator or a list indicator when used
with global object parameters. First reported in version 12.00.00. [Jira 1480161]
In the multi-monitor deployment, the Login dialog box always shows on the primary monitor regardless of
which monitor the Login or Logout command runs on. First reported in version 12.00.00. [Jira 1232807]
If a TrendPro template has two or more traces whose y-axes are positioned at different locations, resetting
the axes and then applying the template does not restore the y-axes' positions saved in the template. First
reported in version 11.00.00. [Jira 856387]
When navigating between screens, images might show as blue boxes on the display client. First reported
in version 11.00.00. [Jira 1009691]
The tag name is truncated in the tag name list of the Highlight Settings dialog box if the tag name is too
long. First reported in version 11.00.00. [Jira 888590]
Rockwell Application Services (RsvcHost) remains in the starting state because the entry of the URL name
and local cache file path in the Index.dat file is broken into multiple lines. First reported in version
10.00.00. [Jira 977498]
In a FactoryTalk View SE client, if a button object on a display changes to a disabled state, the button may
show as enabled after closing and reopening the display. First reported in version 12.00.00. [Jira 1377480]
If electronic signature for the button, numeric input, or string input objects is used, the Accepted and
Rejected events are not available in VBA. First reported in version 12.00.00. [Jira 1294385]
Clicking the Save button does not save the changes made to the Trigger Value or Message boxes in a
local message file. First reported in version 11.00.00. [Jira 986955]
If a graphic display is partially cut off by the FactoryTalk View SE client window, the display is automatically
repositioned to fit within the client window when running the FactoryTalk View SE client. First reported in
version 11.00.00. [Jira 943861]
After running the DerivedOff and DerivedOn command, DerivedTags.exe stops responding. First reported
in version 10.00.00. [Jira 529384]
A TrendPro template from a different application cannot be loaded in TrendPro. First reported in version
11.00.00. [Jira 851117]
The messages logged in FactoryTalk Diagnostics are limited to 500 characters. Messages longer than 500
characters are truncated. The comment in the Command Wizard for the Remark command is limited to
120 characters. First reported in version 12.00.00. [Jira 1453116]
When remotely accessing the FactoryTalk View SE client computer with DeskLock enabled from a
computer with dual monitors of different sizes, after you move the remote screen from the smaller monitor
to the bigger one, the FactoryTalk View SE client does not scale correctly upon maximizing the screen.
First reported in version 11.00.00. [Jira 1314434]
In a multi-monitor deployment, a new dialog box of a TrendPro or Trend object appears on the primary
monitor instead of the monitor where the object is on. First reported in version 12.00.00. [Jira 1269674]
A docked display can be undocked by double-clicking the topmost one-pixel line of the display. First
reported in version 12.00.00. [Jira 1366662]
The FactoryTalk View SE client may unexpectedly close after navigating from a display that contains one
or more local message display objects. First reported in version 10.00.00. [Jira 1320999]
It is possible to change the tag value for a disabled numeric input object if it has focus prior to being
disabled. The numeric input object remains in a state that allows tag updates even if the input focus is
switched to another object on the display. First reported in version 12.00.00. [Jira 1272917]
In a multi-monitor deployment where the displays are configured not to allow multiple copies, if a display is
already open on a top monitor and the same display is launched from the bottom monitor, the position of
that display is shifted up on the bottom monitor. First reported in version 12.00.00. [Jira 1274804]
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
5/18
7/19/23, 3:35 PM
Release Note
Site Feedback
If a button object configured to toggle a certain bit has visibility animation control from a second toggle
button, when it becomes visible, the state returns to 0 even if the controlling bit is still 1. First reported in
version 12.00.00. [Jira 1273774]
A display containing a global object with brackets ([ ]) in the name can be exported but cannot be imported
using the XML format. First reported in version 10.00.00. [Jira 1194073]
Image objects on a graphic display may show as blue boxes after running for a while. First reported in
version 10.00.00. [Jira 1175130]
In FactoryTalk Diagnostics, the audience level of a signature button is Operator instead of Operator &
Secured. First reported in version 12.00.00. [Jira 1156212]
If the region and language settings of Windows are changed where the decimal symbol is changed from a
period (.) to a comma (,), the legend on a Trend object may display the incorrect decimal symbol in the tag
values. First reported in version 12.00.00. [Jira 1156241]
If a FactoryTalk View SE application uses the Trend object in one of the global objects, the global object
parameter configured within the Trend object may not evaluate correctly after the global objects are
compiled. First reported in version 12.00.00. [Jira 1166801]
If you configure a numeric or string input object on a display that is docked when running the FactoryTalk
View SE client, values entered in the numeric or string input object cannot be downloaded. First reported
in version 12.00.00. [Jira 1120247]
After FactoryTalk View SE is upgraded from version 7.00 to version 11.00, an error occurs when passing
the percent character (%) as a parameter to a macro. First reported in version 11.00.00. [Jira 1072971]
If the patch for FTAStub.dll version 7.8.02 from Knowledgebase Document ID: BF26340 - Patch: Activation
generates divergent data for fault tolerant systems, FactoryTalk View 11.0
(https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1129386) is installed, an error
message may appear when opening FactoryTalk View Studio. First reported in version 11.00.00. [Jira
1072558]
When browsing alarm and event tags on a TrendPro object, not all subgroups show in the list if the
subgroups have the same name. First reported in version 12.00.00. [Jira 1004572]
With the TrendPro object configured to use automatic data retrieval, an erroneous line may show in
addition to the actual line if the number of pens is more than 16. First reported in version 11.00.00. [Jira
1021716]
When a global object has global object parameters configured in the grouped object and its subgroup,
some global objects in a graphic display may show as wireframed after compiling. First reported in version
12.00.00. [Jira 1009139]
The ActiveX signature button's terminal client name does not show in FactoryTalk Diagnostics as
configured in the policy settings. First reported in version 12.00.00. [Jira 889856]
A fatal error may happen to FactoryTalk View SE client when using VBA to load a display with the
ShowDisplay method and global objects are referenced in the display. First reported in version 10.00.00.
[Jira 953251]
If running a Replace type of display any time after running a Login command, and the Replace type of
display overlaps a display configured to be On Top and Cannot Be Replaced, the On Top and Cannot
Be Replaced display will close. First reported in version 12.00.00. [Jira 940120]
A FactoryTalk View SE application upgraded to version 11.00 or later may take longer to navigate between
displays. First reported in version 11.00.00. [Jira 948723]
When a FactoryTalk View SE client has a display with a Local Message Display object and the Use
variable message file option is selected, edits to the local message file cannot be saved after a display
has been previously opened where the local message file was used. First reported in version 10.00.00.
[Jira 877091]
In certain cases, if the secondary HMI server in a FactoryTalk View SE application is started, the
secondary HMI server may remain in the starting state. First reported in version 9.00.00. [Jira 898530]
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
6/18
7/19/23, 3:35 PM
Release Note
Known Anomalies in This Release
This release has the following known anomalies.
When data logging is configured to log to a remote computer, after changing the current logged-on
account from an administrator to a standard user, the DataLogOn command cannot be run. First reported
in version 11.00.00. [Jira 1002629]
To resolve this issue, follow the steps to add the user in the ServerFramework DCOM security setting:
1. On the computer on which you plan to run data logging, click Start > Run.
2. In the Open box, type dcomcnfg, and then press Enter.
3. In the Component Services window, on the left side, double-click Component Services >
Computers > My Computer > DCOM Config.
4. In the Applications list, under DCOM Config, right-click ServerFramework, and then click
Properties.
5. In the ServerFramework Properties dialog box, click the Security tab.
6. Select Customize for all the properties on the Security tab.
7. For each property, click Edit, add the user, and then grant all permissions for the user.
Site Feedback
Changes made to the LinkAnimation, LinkConnections, LinkSize, or LinkToolTipText property do not work
on existing reference objects. First reported in version 13.00.00. [Jira 1197803]
The changes will work on newly created reference objects.
If FactoryTalk Batch View is installed with the default port 443, and then FactoryTalk View SE is installed
with HTTPS enabled on the same computer, which also configures port 443, this will cause a port conflict.
As a result, FactoryTalk Batch View client and HMI user controls cannot communicate with the FactoryTalk
Batch View server. First reported in version 13.00.00. [Jira 1525370]
To resolve this issue, after the installation, change the port number used by FactoryTalk View SE in:
Site binding in Internet Information Services (IIS) Manager
FactoryTalk View SE's HTTPS protocol properties in FactoryTalk Administration Console
Known Anomalies from Previous Releases
These anomalies are from previous releases but are still known in this release.
Applying color animations to an object group as well as to the individual objects in the group causes
unexpected behaviors. First reported in version 8.00.00. [346758]
To set up color animations for an object group, either apply the color animations to the group, or to the
individual objects in the group.
If a FactoryTalk View SE datalog becomes disconnected from a remote ODBC database and then
eventually becomes reconnected, it fails to continue logging data to the ODBC database. First reported in
version 8.20.00. [359289]
To resolve this issue, follow the steps below:
1. In the datalog configuration, specify a backup ODBC database. If a disconnection occurs to the
primary ODBC database, the logging of data will now continue to the backup ODBC database.
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
7/18
7/19/23, 3:35 PM
Release Note
2. The connection to the primary ODBC database has recovered and you do not have a backup ODBC
database configured. To make the datalog resume logging to the primary ODBC database, issue the
command Datalogoff <name of datalog> and then the command Datalogon <name of datalog> .
For additional information, see Knowledgebase Document ID: BF10231 - FactoryTalk View SE
datalog fails to continue when disconnected and reconnected to a remote ODBC database
(https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/747699).
When Alarm and Event Log Viewer is opened from the FactoryTalk View SE Client but cannot get events
from the SQL Server database, the FactoryTalk View SE Client does not respond for a few minutes. First
reported in version 7.00.00. [344892]
To resolve this problem, on the toolbar of Alarm and Event Log Viewer, click Stop to stop reading events
from the database.
When login from ThinManager directly to FactoryTalk View SE Client, some warnings about the password
do not show on FactoryTalk View SE Client. For example, the password expires or will expire, or the
password needs to be changed. First reported in version 10.00.00. [367304]
To resolve the issue, check messages in FactoryTalk Diagnostics and follow the instructions accordingly.
Timeout may occur when you perform backup or restore operation through an unstable or slow network.
First reported in version 8.10.00. [355276]
To resolve this issue, open the Registry Editor of the computer that runs the tool, update the registry key
CompressTimeout to a value larger than 1200 and try again. The key is in
HKEY_CURRENT_USER\Software\Rockwell Software\RSView
Enterprise\DistributeApplicationManager\Settings.
Site Feedback
When multiple SE clients are launched simultaneously on the same computer, the startup of the SE clients
may not respond at the Loading Command Server stage. First reported in version 8.10.00. [368162]
To resolve this issue, create a Windows batch file and add a Pause 5 command between the launch of
each SE client file. This will allow the start of each SE client to be offset from each other.
During the restore operation, when overwriting components of a running HMI server, some components of
the server may still exist in the HMI folder after you restart the computer. This happens when the names of
these components do not exist in the archived HMI file. First reported in version 8.10.00. [354220]
There is a possibility that some object properties that are configured in character sets for east Asian
languages such as Chinese or Japanese, will display a question mark in the result list when you use the
Find and Replace, Cross Reference or Undo feature. First reported in version 7.00.00. [338894]
To resolve this problem, go to Control Panel > Regional and Language Options, and select the
appropriate language to match the language version desired.
When registering or unregistering an ActiveX Control object in FactoryTalk View Studio with User Account
Control (UAC) enabled on the operating system, an error message shows. First reported in version
8.00.00. [346124]
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
8/18
7/19/23, 3:35 PM
Release Note
To avoid this problem, before registering or unregistering an ActiveX Control object, do one of the
following:
Turn off UAC and restart the computer
Run FactoryTalk View Studio as administrator
If you copy and paste a PNG image into an application, the image might appear blurred. First reported in
version 7.00.00. [337726]
To avoid this issue, import the image into the Image folder first, and then insert the image into the
application from the Image folder.
VBA execution may pause temporarily while an HMI server is replicating. First reported in version 7.00.00.
[361749]
If you configure NIC speed remotely to Auto, (rather than to 100 Mb Full), it doubles the amount of time to
open the tag editor. First reported in version 6.10.00. [270579]
To avoid this issue, we recommend that you configure NIC speed to the highest value possible.
Site Feedback
During replication some project information may fail to replicate to secondary servers. First reported in
version 8.00.00. [347733]
To resolve this issue, restart these secondary servers and replicate again. If the replication still fails, cancel
the redundancy configuration and delete HMI project from secondary servers, restart secondary servers,
and configure the redundancy again.
When running FactoryTalk View SE redundant applications on Windows 10 Professional or Enterprise
v1607 operating systems, initiating a network connectivity break by disabling NIC adaptors in Device
Manager can cause application failures requiring a restart of the application. This issue was introduced in
the Windows 10 v1607 feature build. First reported in version 9.00.00. [363223]
To avoid this problem, run the Microsoft Hotfix KB3201845 outlined in https://support.microsoft.com/enus/kb/3201845.
Alternatively, you can run Windows 10 v1703 or other supported operating systems where this issue is not
present.
For more information about Windows 10 operating system support, see Knowledgebase Document ID:
IN4493 - Windows 10 Support for the FactoryTalk Suite of Rockwell Software products
(https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/964391).
For more information about Windows Server 2016 operating system support, see Knowledgebase
Document ID: IN4718 - Windows Server 2016 Support for the FactoryTalk Suite of Rockwell Software
products (https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/991031).
If IPv6 is not supported or is disabled in your network environment, when you use FactoryTalk View Studio
on Windows 8.1, Windows 8, Windows Server 2012 R2, or Windows Server 2012, the network
communication performance may be slow. First reported in version 8.00.00. [347310]
To resolve this issue, you may need to disable IPv6 on your computer or enable IPv6 in your network
environment. Contact your IT department for details.
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
9/18
7/19/23, 3:35 PM
Release Note
If your system is experiencing HMI tag failures and wireframing, you may have a port conflict. Check the
event log for the message: "Unable to establish connection with Live Data using
TCP/IP protocol. Port may be in use by another process." The HMI tag failures could
occur on any operating system due to dynamic port range changes. First reported in version 5.10.00.
[264248]
To resolve this, you will need to manually change the port. For additional information on how to do this,
see Knowledgebase Document ID: QA7128 - FactoryTalk View Site Edition: Unable to establish
connection with Live Data using TCP/IP protocol
(https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/61064).
On Microsoft Surface tablets, the press and hold gesture may not open a component's menu if the
component is a text box. First identified in FactoryTalk View 9.00.00. [362400]
To work around this problem, use a mouse and right-click the component to open the menu.
Timeout may occur when you try to load large amounts of data points from an ODBC data source such as
SQL Server, and the Trend object does not show the historical data. First reported in version 7.00.00.
[343026]
To resolve this issue, open the Registry Editor, update the key DatalogOdbcDbTimeout to a larger value
in the following two locations, and try again:
HKEY_USERS\.DEFAULT\Software\Rockwell Software\RSView Enterprise\Data Log
Site Feedback
Updating to the new KEPServer Enterprise version, V5.7, may require updating the OPC Data Server
configuration after a restoring an application file. First reported in version 6.10.00. [276028]
To resolve this issue, on the OPC Data Server configuration tab, update the computer name then restart
the computer before browsing for the new Prog ID for KEPServer Enterprise.
HKEY_USERS\S-1-5-18\Software\Rockwell Software\RSView Enterprise\Data Log
When switching from Daylight Saving Time back to Standard Time, you will see two 1:00 hours on the
trend chart of a TrendPro object. If you trend data from data logs, one hour data is not displayed on the
trend chart and seems to be lost. All data actually is in the database and no data is lost. First reported in
version 9.00.00. [363699]
To view the data that is not displayed, add a real-time trace to the chart. For more information, see
Knowledgebase Document ID: QA4519 - Trends and Daylight Saving Time (DST)
(https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/39658).
HMI project folder does not replicate to secondary HMI Server. This issue can be caused by a couple of
situations. One cause could be the size of the HMI project file being larger than the maximum allowable
file transfer size. The other cause could be the replication taking longer than the default time limit of 20
minutes.
To resolve this issue, change the limit size to an acceptable value or set the limit time to a larger value. For
more instructions, see Knowledgebase Document ID: QA3577 - FactoryTalk View Site Edition HMI Project
Replication Process Steps
(https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/38407).
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
10/18
7/19/23, 3:35 PM
Release Note
The reference object of a momentary button shows an incorrect initial state when the display containing
the reference object is run on the FactoryTalk View SE client. First reported in version 11.00.00. [Jira
845437]
After pressing the momentary button, the state returns to normal.
At runtime, the context menu of Trend cannot be shown on the screen when trying to trigger by pen or
finger. First reported in version 12.00.00. [Jira 42333]
Use a mouse or another pointing device to access the context menu of the Trend.
Unable to change the historian server on a TrendX object for pens in the Model column. First reported in
version 10.00.00. [Jira 42006]
There is no workaround for this anomaly. However, TrendPro supports the change of the historian server
from the configuration page.
Functional Changes
This release has the following functional changes from the previous release.
FactoryTalk View SE version 13.00.00 has the following changes in functionality since the last release.
If you install Studio Enterprise, Site Edition Server, or FactoryTalk ViewPoint SE on a computer with no
FactoryTalk View component installed, the installation enables HTTPS by default.
Site Feedback
HTTPS enabled by default
If HTTPS is enabled, you must configure a TLS certificate after installation. If you do not configure the certificate,
there will be unexpected errors when operating FactoryTalk View SE components. For details on configuring a
TLS certificate, see FactoryTalk View Site Edition Installation Guide.
Application Notes
This release has the following application notes.
The following are the application notes for FactoryTalk View SE version 13.00.00.
HTTPS enabled by default
If you install Studio Enterprise, Site Edition Server, or FactoryTalk ViewPoint SE on a computer with no
FactoryTalk View component installed, the installation enables HTTPS by default.
If HTTPS is enabled, you must configure a TLS certificate after installation. If you do not configure the certificate,
there will be unexpected errors when operating FactoryTalk View SE components. For details on configuring a
TLS certificate, see FactoryTalk View Site Edition Installation Guide.
Mitigation for Microsoft DCOM Hardening patch
In response to Microsoft Distributed Component Object Model (DCOM) Hardening patch (MS KB5004442), the
minimum DCOM authentication level used by Rockwell Automation products was raised to Packet Integrity.
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
11/18
7/19/23, 3:35 PM
Release Note
IMPORTANTInstalling this product’s latest version with earlier unpatched versions of other
FactoryTalk products or products using Classic OPC DA connections may cause a
loss of connectivity due to the difference in DCOM authentication level used. For
additional information, see the Knowledgebase Document ID: IN39461 - Microsoft
DCOM Hardening Information TOC
(https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1133991).
Microsoft releases the DCOM Hardening patch in response to CVE-2021-26414. This patch elevates the
minimum DCOM authentication level that is required to establish a DCOM connection. DCOM is used by many
Rockwell Automation products and may be affected by the change that is made by the Microsoft patch. For
additional information about the affected Rockwell Automation products, see the Knowledgebase Document ID:
PN1581 - Product Notification 2022-01-001 - Rockwell Automation products unable to establish proper DCOM
connection after installing Microsoft DCOM Hardening patch (MS KB5004442)
(https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1133982).
Change in operating system support
Beginning in this release, the product installer prevents installation on all 32-bit versions of Windows operating
systems (for example, Windows 10, 32-bit) and any Windows 7 operating system (for example, Windows 7
Professional, 64-bit).
Considerations for application server host computers
One FactoryTalk View SE Server
One FactoryTalk Linx data server (which can also be set up as FactoryTalk Alarms and Events devicebased alarm server, or also includes the secondary data server)
One FactoryTalk Alarms and Events tag-based alarm server
The FactoryTalk Network Directory
Site Feedback
In a network application, it is possible for a single server computer that meets the recommended requirements to
host all of the following components:
If a network application requires multiple HMI servers, data servers, or alarm servers, to distribute the load, it is
recommended that you install the necessary software and run the servers on multiple host computers.
For information about setting up redundant FactoryTalk View SE servers, see FactoryTalk View Site Edition
User’s Guide.
FactoryTalk Diagnostics
FactoryTalk Diagnostics cannot log to a remote database using Microsoft Access. You can only log to a local
database using Microsoft Access.
Find and Replace
If an HMI server at the root node of an SE Network distributed application has the same name as the application
itself, the Find and Replace feature search results might include the application name even though you
performed the search at the HMI server level.
Floating-point operations
Floating-point numbers may not precisely represent all real numbers. Floating points only has six digits of
precision. As a result, expressions based on floating-point arithmetic operations may not evaluate as expected.
This is a side effect of how the CPU represents the floating-point data. For this reason, in certain cases you may
experience loss of precision and get unexpected results of floating-point operations.
KEPServer
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
12/18
7/19/23, 3:35 PM
Release Note
If you are using KEPServer Enterprise as an OPC server with FactoryTalk View version 9.00.00 or later and
using an HMI tag to connect to a third-party device, you will not be able to access the tag value. The cause is
that the security enhancements in FactoryTalk View version 9.00.00 or later affect the communications with thirdparty devices. To access the tag value, additional Distributed Component Object Model (DCOM) configuration is
required for KEPServer Enterprise on the computers.
For more information about the configuration, see Appendix, "Troubleshoot KEPServer Enterprise" in the
FactoryTalk View SE Installation Guide.
Pre-installation configuration
Before you install FactoryTalk View SE, there are a number of steps required to set up the installation
environment. This will help ensure that the installation proceeds smoothly and that your new or upgraded
FactoryTalk system operates as expected. For detailed information about pre-requisites before installation, see
Chapter 3, Pre-installation configuration of FactoryTalk View Site Edition Installation Guide.
Security requirements
File extensions created by Rockwell Automation software, firewall rules, and service dependences, see
Knowledgebase Document ID: PN826 - Security considerations when using Rockwell Automation
Software Products (https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/609492).
TCP/UDP ports used by Rockwell Automation products, see Knowledgebase Document ID: BF7490 TCP/UDP Ports Used by Rockwell Automation Products
(https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/898270).
System sizing recommendations
Site Feedback
For information on the security considerations when using Rockwell Automation products, including
When you design and set up a FactoryTalk system, we recommend using the following guidelines. If you find that
your system needs to expand beyond these guidelines, contact your Rockwell Automation sales or distributor
representative to discuss your application design.
Component
Recommended guidelines
FactoryTalk Alarms and Events
FactoryTalk Alarms and Events servers per FactoryTalk
Directory
10 non-redundant servers or 10 redundant server
pairs1
FactoryTalk tag-based alarms per server
20,0002
Logix device-based alarms per server
10,0003
Total alarms per FactoryTalk Directory
100,0004
FactoryTalk Linx
FactoryTalk Linx data servers per FactoryTalk Directory
10 non-redundant servers or 10 redundant server
pairs1
Total device tags per FactoryTalk Directory
1,000,0005
Tags per FactoryTalk Linx data server
100,0005
FactoryTalk View SE
HMI servers per FactoryTalk Directory
10 non-redundant servers or 10 redundant server
pairs1
HMI tags per HMI server
40,0006
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
13/18
7/19/23, 3:35 PM
Release Note
Total data logged tags per HMI server (1 second scan rate)
5,000
FactoryTalk View SE client sessions simultaneously connected 1205
to the application
FactoryTalk ViewPoint SE servers per application
4
FactoryTalk ViewPoint SE concurrent clients per ViewPoint
50
server
1. Because multiple applications can run simultaneously within the same FactoryTalk Directory, the
recommended number refers to the sum of servers across applications in one FactoryTalk Directory.
2. The number of alarm backing tags influences the maximum number of available alarms because they
increase the resource requirements of the alarm server. When using backing tags for status and control, a
good rule of thumb is to multiply the total number of backing tags by the total number of alarms, and ensure
the result is less than 20,000. PlantPAx® users should refer to the PlantPAx Reference Manual PROCESRM001 (http://literature.rockwellautomation.com/idc/groups/literature/documents/rm/proces-rm001_-en-p.pdf)
for alarm server sizing guidance for a PlantPAx application.
3. This number is the sum of both instruction alarms and Logix tag-based alarms across all the controller
shortcuts in each FactoryTalk Linx server.
4. The total number of alarms per FactoryTalk Directory includes all FactoryTalk Alarms and Events tag-based
and device-based alarms in the directory.
5. Refer to Knowledgebase Document ID: IN7377 - Amounts of device tags that may have in FactoryTalk View
SE application (https://rockwellautomation.custhelp.com/app/answers/answer_view/a_id/1070902) for
detailed information to determine system scalability for the total device tags per FactoryTalk Directory.
6. The maximum number of HMI tags that can be created on a single HMI server is 175,000. Extensive use of
HMI tags has a significant performance impact on an HMI server, so Rockwell Automation recommends
minimizing their use, and instead using direct-reference tags as much as possible.
If you rename an HMI server while you are deploying an application, you may need to restart the computer in
order to have the HMI tags show up in the Tag Browser.
Tools and utilities
Site Feedback
Tag Browser
In the DeskLock utility, all Windows hot keys are disabled except the Windows Logo + L combination,
which still locks the Windows Desktop.
In the Tag Import and Export Wizard, you are recommended to close the running project while importing a
tag CSV file containing large amounts of tags and alarms. Otherwise, you will need to wait a few minutes
and the Server Busy Dialog box may pop up.
Trend objects
The Trend objects cannot get the oldest data from FactoryTalk Historian server when you click the Oldest Data
button.
TrendPro objects
Clicking on the X-axis or Y-axis takes it into the free layout mode. In this case, anything done to the canvas
is how you want it and it does not resize. The free mode does not persist scale and removes tags from the
trend. Avoid using the free mode in the trend.
UAC support
Turning off User Account Control (UAC) is not recommended.
This action
Configuring Internet Information Services
(IIS)
Prompts for authentication or confirmation before running this
program
RSViewWebManager.exe
CustomWebSite.exe
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
14/18
7/19/23, 3:35 PM
Release Note
Updating Samples application directory
information
RefreshSampleApplication.exe
End processes
VSClean.exe
DeskLock
DeskLock2000.exe
Legacy Tag Database Conversion
LegacyTagDBConvertTool.exe
VeriSign Universal Root Certification Authority certificate
If the VeriSign Universal Root Certification Authority certificate does not exist on the local computer, the
certificate is installed while installing Rockwell Automation software. Use Microsoft Management Console (MMC)
to view the certificate in Console Root > Certificates (Local Computer) > Trusted Root Certification
Authorities > Certificates.
Unattended installation
Use command-line parameters to perform an unattended or silent installation of the software.
Command-line parameters
Parameter
Description
/?
Displays the usage options for installation parameters.
Silent Install, install runs in a quiet mode without any user interface.
/Q
This parameter is recommended when deploying the software installation
using an IT tool or script, and don’t expect any error or restart messages.
When using this parameter, check the error codes, and respond as
needed. For example, if the installation returns error code 1641, then the
IT tool or script should restart the computer and relaunch the installation
after restart.
/QS
Site Feedback
The following table identifies the installation command-line parameters. Command-line parameters are caseinsensitive. However, if a specified value includes a space, be sure to enclose the value in quotation marks (for
example, "value with spaces").
This parameter is required if /QS is not specified.
Unattended Install, install runs in a quiet simple mode and shows
progress through the UI, it does not accept any input but still shows error
or restart messages.
When using this parameter, the installation will stop and display a prompt
if there are error or restart messages. For example, if an immediate
restart is required to complete the install, a restart message will be
displayed to confirm the restart. Installation resumes automatically from
the point of interruption after restart.
/IAcceptAllLicenseTerms
/AutoRestart
/Record
This parameter is required if /Q is not specified.
Acknowledges acceptance of the license terms.
This parameter is required for /Q or /QS parameters.
Automatically restarts the computer after the installation is complete.
Used when a restart is required to complete the installation.
This parameter is optional. If this parameter is not used, silent install (/Q)
will return either error code 1641 or 3010 if a restart is required, and
unattended install (/QS) will result in a confirmation prompt that must be
agreed to before the installation is completed.
Records the installation options chosen to a recording file.
This parameter is optional.
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
15/18
7/19/23, 3:35 PM
/Playback
/Repair
Release Note
Plays back a recording file to specify the installation options.
This parameter is optional.
Runs a repair operation on the installed products.
This parameter is optional.
/Uninstall
/SetupLanguage="value"
Uninstalls the product.
Specifies which language will be displayed during install process.
The value must be the one of the following:
ENU
CHS
DEU
ESP
FRA
ITA
JPN
KOR
PTB
/Product="value"
This parameter is optional. If this parameter is not used, the default
language is the current user or operating system user interface
language.
Specifies which sub-products will be installed.
For FactoryTalk View ME, the value must be one of the following:
Studio for Machine Edition
Machine Edition Station for Windows
Stand-alone ME Transfer Utility
For FactoryTalk View SE, the value must be one of the following:
Studio Enterprise
Site Edition Server
Site Edition Client
Site Edition Station
FactoryTalk ViewPoint SE
Stand-alone FactoryTalk Linx Server
Stand-alone FactoryTalk Directory Server
/ProductLanguage="value"
Site Feedback
This parameter is required.
Specifies the language version of the software being installed.
The value must be one of the following:
ENU
CHS
DEU
FRA
JPN
This parameter is optional. If this parameter is not used, the default
language is the same as the setup language.
/InstallDrive="value"
/IgnoreWarning
If the software does not support multiple languages, this parameter is not
available.
Specifies the installation drive.
This parameter is optional. If this parameter is not used, the default
install drive is C:.
Specifies that the setup ignores warnings and continues.
This parameter is optional. If it is not specified, the setup exits when a
warning occurs.
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
16/18
7/19/23, 3:35 PM
/SerialNumber="value"
Release Note
Specifies the serial number of the software being installed. This is used
to activate the software during installation.
This parameter is optional. If it is not specified, the software must be
activated manually after installation if activation is required.
/ProductKey="value"
Some software does not require activation. If activation is not required,
this parameter is not available.
Specifies the product key used to get activation keys during installation.
This parameter is optional. If it is not specified, the software must be
activated manually after installation if activation is required.
/Version="value"
Some software does not require activation. If activation is not required,
this parameter is not available.
Specifies the version of the software to activate, which corresponds to
the product version associated with the SerialNumber and ProductKey.
This parameter is optional. If it is not specified, the installer will use the
most recent product version available.
/DirectoryServer="value"
Some software does not require activation. If activation is not required,
this parameter is not available.
Specifies the FactoryTalk network directory if you are using a distributed
system.
/NoHTTPS
The value must be the host name of the FactoryTalk Directory server.
Specifies that the setup turns off HTTPS.
This parameter is optional. If it is not specified, the setup turns on HTTPS
for communication, and a TLS certificate must be configured after
installation.
Error codes
Site Feedback
This parameter is optional. If it is not specified, the software will use its
current computer as the FactoryTalk Directory server.
The following table identifies the error codes that can be returned by an installation.
Error Code
Value
Description
ERROR_SUCCESS
0
The installation completed successfully.
ERROR_INVALID_PARAMETER
87
One of the parameters was invalid.
ERROR_INSTALL_USEREXIT
1602
The installation was canceled by the user.
ERROR_INSTALL_FAILURE
1603
A fatal error occurred during installation.
ERROR_BAD_CONFIGURATION
1610
The configuration data for this product is corrupt. Contact
your support personnel.
ERROR_SUCCESS_REBOOT_INITIATED 1641
The installer has initiated a restart. After restart, the
installation will continue.
ERROR_SUCCESS_REBOOT_REQUIRED3010
A restart is required to complete the installation. After
restart, the product is successfully installed.
ERROR_REBOOT_PENDING
3012
Restart pending. Restart the computer for the installation to
continue.
ERROR_SUCCESS_NOT_APPLICABLE
3013
The installation cannot proceed because the products are
already installed.
https://compatibility.rockwellautomation.com/GeneratedReleaseNote.aspx?v1=60879
17/18
7/19/23, 3:35 PM
ERROR_SUCCESS_WARNING_REBOOT 3014
Release Note
The installation succeeded with warnings. Check the
installation log file for details. To complete the installation,
restart the computer.
Rockwell Automation recognizes that some of the terms that are currently used in our industry and in this
publication are not in alignment with the movement toward inclusive language in technology. We are proactively
collaborating with industry peers to find alternatives to such terms and making changes to our products and
content. Please excuse the use of such terms in our content while we implement these changes.
Site Feedback
Copyright © 2023 Rockwell Automation, Inc. All rights reserved.
Rockwell Automation, Allen-Bradley, and FactoryTalk are trademarks of Rockwell Automation, Inc.
To view a complete list of Rockwell Automation trademarks please click here.