GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 1 of 77 Home https://device.report/manual/8787491 Latest Devices Certifications GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology Instruction Manual device› / GE Healthcare / GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology Instruction Manual GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 2 of 77 https://device.report/manual/8787491 Product Information The product is the GE Healthcare Pre Installation manual for the INNOVA IGS 620-630 FINAL STUDY system. It is a set of drawings and specifications that provide guidance for site design and preparation before installing the GE Healthcare product. The manual includes various sections such as general notes, equipment layout, structural details, HVAC, electrical layout, power requirements, and interconnections. It also emphasizes the importance of referencing the Pre Installation manual to ensure complete documentation for site design and preparation. Additionally, the manual mentions that GE Healthcare does not take responsibility for damages resulting from changes made by others to the drawings. It also advises against scaling from printed pdf files and states that GE accepts no responsibility or liability for defective work due to scaling from these drawings. The 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 3 of 77 https://device.report/manual/8787491 manual is in A3 format with a scale of 1/4=1'-0. The file name is ENVAS-TYP-IGS-6X0-WEB.DWG. There is also a reference to the PIM Manual 5694389-1-1EN, which provides further information and specifications for the product. Product Usage Instructions 1. Before starting the installation of the GE Healthcare INNOVA IGS 620-630 system, it is essential to refer to the Pre-Installation manual provided. 2. Ensure that all necessary site design and preparation documentation is complete by following the guidelines in the manual. 3. Familiarize yourself with the different sections of the manual, including general notes, equipment layout, structural details, HVAC, electrical layout, power requirements, and interconnections. 4. Take note of the warnings and disclaimers mentioned in the manual, such as GE Healthcare not taking responsibility for changes made by others to the drawings and the potential issues with scaling from printed pdf files. 5. Follow the specified format and scale of the drawings, which are in A3 size with a scale of 1/4=1'-0. 6. Make sure to access the PIM Manual 5694389-1-1EN for additional information and specifications related to the product. 7. Adhere to the customer responsibilities mentioned in the manual, such as ensuring room dimensions, ceiling support structure, 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 4 of 77 https://device.report/manual/8787491 cleanliness, cableways, and adequate illumination meet GE specifications. 8. Install the system according to the guidelines provided in the manual, including the installation of countertops, vascular baseplates, and table baseplates if applicable. 9. Follow any specific requirements mentioned in the manual for floor finish and protection for the IGS 730/740 models. 10. If there are any uncertainties or questions regarding the installation process, contact a GE Healthcare representative for assistance. DISCLAIMER GENERAL SPECIFICATIONS GE is not responsible for the installation of developers and associated equipment, lighting, cassette trays and protective screens or derivatives not mentioned in the order. The final study contains recommendations for the location of GE equipment and associated devices, electrical wiring and room arrangements. When preparing the study, every effort has been made to consider every aspect of the actual equipment expected to be installed. The layout of the equipment offered by GE, the dimensions given for the premises, the details provided for the pre-installation work and electrical power supply are given according to the information noted 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 5 of 77 https://device.report/manual/8787491 during on-site study and the wishes expressed by the customer. The room dimensions used to create the equipment layout may originate from a previous layout and may not be accurate as they may not have been verified on site. GE cannot take any responsibility for errors due to lack of information. Dimensions apply to finished surfaces of the room. Actual configuration may differ from options presented in some typical views or tables. If this set of final drawings has been approved by the customer, any subsequent modification of the site must be subject to further investigation by GE about the feasibility of installing the equipment. Any reservations must be noted. The equipment layout indicates the placement and interconnection of the indicated equipment components. There may be local requirements that could impact the placement of these components. It remains the customer's responsibility to ensure that the site and final equipment placement complies with all applicable local requirements. All work required to install GE equipment must be carried out in compliance with the building regulations and the safety standards of legal force in the country concerned. These drawings are not to be used for actual construction purposes. The company cannot take responsibility for any damage resulting therefrom. 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 6 of 77 https://device.report/manual/8787491 CUSTOMER RESPONSIBILITIES It is the responsibility of the customer to prepare the site in accordance with the specifications stated in the final study. A detailed site readiness checklist is provided by GE. It is the responsibility of the customer to ensure all requirements are fulfilled and that the site conforms to all specifications defined in the checklist and final study. The GE Project Manager of Installation (PMI) will work in cooperation with the customer to follow up and ensure that actions in the checklist are complete, and if necessary, will aid in the rescheduling of the delivery and installation date. Prior to installation, a structrual engineer of record must ensure that the floor and ceiling is designed in such a way that the loads of the installed system can be securely borne and transferred. The layout of additional structural elements, dimensioning and the selection of appropriate installation methods are the sole responsibility of the structural engineer. Execution of load bearing structures supporting equipment on the ceiling, floor or walls are the customer's responsibility. RADIO-PROTECTION Suitable radiological protection must be determined by a qualified radiological physicist in conformation with local regulations. GE does 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 7 of 77 https://device.report/manual/8787491 not take responsibility for the specification or provision of radioprotection. THE UNDERSIGNED, HEREBY CERTIFIES THAT I HAVE READ AND APPROVED THE PLANS IN THIS DOCUMENT. DATE NAME SIGNATURE GLOBAL SITE READINESS CHECKLIST (DI) DOC1809666 Rev. 7 Site Ready Checks at Installation EHS Site Requirements Overall access route to the scan room free from obstruction / high ha zards. Enough space to store tools, equipment, parts, install waste and the g eneral area free from obstruction and trip hazards. Enough necessary facilities for the GE employees available. No 3rd parties working in the area that may affect the safety of the in stallation activity. 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 8 of 77 https://device.report/manual/8787491 Area free from any chemical, gas, dust, welding fume exposure and h as painting been completed and dry. All emergency routes identified, signed and clear from obstruction. Accessible single source lockable panel that LOTO can be applied to f or GE equipment installation (MDP and/or PDU). There are no other conditions or hazards that you have observed or h ave been made aware of by the customer or contractors on site. Required for Mechanical Install start Room dimensions, including ceiling height, for all Exam, Equipment/T echnical & Control rooms meets GE specifications. Ceiling support structure, if indicated on the GE drawing, is in the corr ect location and at the correct height according to the Original Equip ment Manufacturer specifications. Levelness and spacing has been measured, and is ready for the install ation of any GE supplied components. Overhead support Structure (unistrut) has been confirmed with custo mer/contractor to meet required GE provided criteria. Finished ceiling is installed. If applicable ceiling tiles installed per PMI 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 9 of 77 https://device.report/manual/8787491 discretion. Floor levelness/flatness is measured and within tolerance, and there a re no visible defects per GEHC specifications. Entry door threshold meets PIM requirement Floor Strength and thickness have been discussed with customer/cont ractor and they have confirmed GE requirements are met. Rooms that will contain equipment, including staging areas if applica ble, are construction debris free. Precautions must be taken to preven t debris from entering rooms containing equipment. Cable ways (floor/wall/ceiling/Access Flooring) are available for install ation of GE cables are of correct length and diameter. Cable ways routes per GE Final drawings and cable access openings a reas installed at a time determined by GEHC PM. Surface floor duct ca n be installed at time of system installation. Adequate room illumination installed and working. Customer supplied countertops where GE equipment will be installed are in place. Vascular baseplates preparation complete per GE requirements. 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 10 of 77 https://device.report/manual/8787491 For IGS 730/740: Floor finish is according to the GE Specifications and protection is installed . Specifications for concrete substrate & Mono pur 7 mm flooring have been met. Table baseplate installed and flush to the finished floor. For IGS 730/740: Room Interventional Reference Point (RIRP) value ha s been defined with the customer. Either 1120mm, 1278 mm or 1508 mm. Ensure that all third party suppliers are identified and have been infor med about the project dates and how they need to proceed in accord ance with their needs for interfacing to our equipment. Required for Calibration start HVAC systems Installed, and the site meets minimum environmental operational system requirements. System power & grounding (PDB/MDP) is available as per GE specific ations. System power & grounding (PDB/MDP) is installed at point of final co nnection and ready to use. Lock Out Tag Out is available. PMI to confirm all feeder wires and breaker are size appropriately. EP O installed if needed. 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 11 of 77 https://device.report/manual/8787491 PMI to confirm with electrician all power and signal cables are well ter minated ensuring there are no loose connections. Network outlets installed. Computer network available and working. Lead doors and windows complete or scheduled to be installed. If ap plicable, radiation protection (shielding) finished & radioprotection re gulatory approval for installation obtained. Note: The details shown here are only an extract from DOC1809666. For the complete document please contact your PMI. INTERFERENCE SPECIFICATIONS MAGNETIC INTERFERENCE SPECIFICATIONS Image intensifiers must be located in ambient static magnetic fields of less than 1 gauss to guarantee specified imaging performance. X-ray tubes must be located in ambient static magnetic fields of less than 10 gauss to guarantee specified performance. System electronics must be located in ambient static magnetic fields of less than 10 gauss to guarantee data integrity. Operators console equipment must be located in ambient static magnetic fields of less than 10 gauss to obtain specified geometric 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 12 of 77 https://device.report/manual/8787491 linearity. CUSTOMER SITE READINESS REQUIREMENTS Any deviation from these drawings must be communicated in writing to and reviewed by your local GE healthcare installation project manager prior to making changes. Make arrangements for any rigging, special handling, or facility modifications that must be made to deliver the equipment to the installation site. If desired, your local GE healthcare installation project manager can supply a reference list of rigging contractors. New construction requires the following; 1. Secure area for equipment, 2. Power for drills and other test equipment, 3. Capability for image analysis, 4. Restrooms. Provide for refuse removal and disposal (e.g. crates, cartons, packing) For CT, MR, PET/CT, and SPECT systems it is required to minimize vibrations within the scan room. It is the customer's responsibility to contract a vibration consultant/engineer to implement site design modifications to meet the GE vibration specification. Refer to the system preinstallation manual for vibration specifications. ELECTROMAGNETIC INTERFERENCE The system is suitable for use in the specified electromagnetic 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 13 of 77 https://device.report/manual/8787491 environment. The purchaser or user of the system should assure that it is used in an electromagnetic environment as described below: EMISSION TEST COMP S LIANCE Radio–F requency E Group1 Cla ss A limits ELECTROMAGNETIC ENVIRONMENT The system is suitable for use in all establ ishments other than domestic and those missions C directly connected to the low voltage po ISPR11 wer supply network that supplies buildin gs used for domestic purposes. Group1 Cla ss A limits The system uses RF energy only for its int ernal function. Therefore, the RF emissio n is very low and not likely to cause any i nterference in nearby electronic equipme nt. Harmonic Not applica The system is suitable for use only in esta emissions I ble blishments not directly connected to a p EC 61000– ublic low voltage power supply network. 3–2 Voltage flu ctuations/ flicker emi Not applic able The system is suitable for use only in est ablishments not directly connected to a public low voltage power supply networ 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 14 of 77 ssions IEC https://device.report/manual/8787491 k. 61000–3–3 A GE Supplied D Available from GE B GE Supplied/contractor installe E Equipment existing in roo d C Customer/contractor supplied m * Item to be reinstalled from 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 15 of 77 https://device.report/manual/8787491 and installed another site MAX B ITEM Y MAX DESCRIPTIO HEAT WE HEAT O WE N OUTPU IG UTPUT IG T HT HT (lb (k s) g) (btu) D 1 Advantage wo (W) 3412 22 1000 10 1405 19. 410 9 rkstation A 2 Operator cons ole D 3 Reference mo 6 1706 18 500 8 5435 80 1590 36 nitor A 4 C1 Frontal Ca binet A 5 C1 Lateral Cab inet 9 3969 69 2 7 1160 31 4 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 16 of 77 A 6 C2 Cabinet https://device.report/manual/8787491 6171 57 1810 8 A 7 Detector cond 709 32 2 210 itioner A 8 COOLIX 4100 9 Chiller Autotra 14. 5 21496 water chiller A 26 26 6300 5 12 0 709 66 210 30 3412 25 1000 11 nsformer A 10 Large Display Cabinet A 11 3kVA LDM UP 4 5 1257 79 370 36 2216 85 650 38 S B/ 12 D A Power Distrib ution Box 13 3kVA PDB UP 9 9.5 1257 79 370 36 4720 10 1380 54 S D 14 20kVA Fluoro UPS UL 65 1 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 17 of 77 https://device.report/manual/8787491 A 15 Xray buzzer - 1 - 0.5 A 16 LC gantry 5517 15 1620 70 56 A 17 LP Gantry 5517 17 5 1620 57 A 18 Longitudinal s 79 7 - 68 - 31 - - - - 614 16 180 75 tationary rail f or LP Gantry B 19 Cable drape r ail for LP Gant ry A 20 OMEGA V pati ent table A 21 Monitor suspe 64 4.5 - - - - - 68 - 31 nsion short bri dge A 22 Longitudinal s tationary rail 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 18 of 77 D 23 Large Display https://device.report/manual/8787491 - Monitor with t 88 - 0 39 9 wo backup m onitors D 24 Mavig rad shi - eld and LED la 14 - 65 - 3 3 mp with 2.5m ceiling track D 25 External Transf - 6 ormer for LED Surgical lamp Circuit breaker or equivalent with LOTO must be installed in the mains line to the PDB C 26 this device must be compatible with the power i nput specifications of the system. the customer is responsible for procurement, delive ry, and installation. C 27 Cable drape rail. C 28 Control wall to ceiling with lead glass viewing w 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 19 of 77 https://device.report/manual/8787491 indow. C 29 Scrub sink C 30 Countertop for equipment- provide grommeted openings as required to route cables C 31 Minimum door opening for equipment delivery is 44 in. w x 83 in. h [1118mm x 2108mm], conti ngent on a 96 in. [2438mm] Corridor width C 32 Storage Cabinet EXAM ROOM HEIGHT FINISHED FLOOR-TO-FALSE CEILING Require Require d d 2845mm 9'-4" +/0.2" Door openings: Exam room min 1160 [50 in], Technical room min 800 [36 in], rec 1000 [40 in] For Accessory Sales: (866) 281-7545 Options 1, 2, 1, 2 or mail to: gehcaccessorysales@ge.com CONTROL ROOM VIEW 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 20 of 77 https://device.report/manual/8787491 EXAM ROOM VIEW TECHNICAL ROOM VIEW 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 21 of 77 https://device.report/manual/8787491 TECHNICAL ROOM VIEW GANTRY Center of Gravity SCALE 1:50 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 22 of 77 https://device.report/manual/8787491 LATERAL POSITIONER OMEGA V PATIENT TABLE Center of Gravity Scale 1:20 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 23 of 77 https://device.report/manual/8787491 INNOVA CABINETS CENTER OF GRAVITY CABIN C1 (AP) C1 (LAT) C2 ET DIMEN mm in mm in mm in A 452 17.7 506 19.9 400 15.7 B 283 11.1 338 13.3 325 12.8 C 904 35.5 839 33.0 948 37.3 SION 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 24 of 77 https://device.report/manual/8787491 LARGE DISPLAY CABINET DIGITAL ENERGY SG SERIES 10-20kVA UPS 3kVA UPS 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 25 of 77 https://device.report/manual/8787491 X-RAY TUBE CHILLER COOLIX AUTOTRANSFORMER 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 26 of 77 https://device.report/manual/8787491 DETECTOR CONDITIONER DELIVERY The customer should Provide an area adjacent to the vascular suite for delivery and unloading of the GE equipment. Ensure that the dimensions of all doors, corridors, ceiling heights are sufficient to accommodate the movement of GE equipment from the delivery area into the definitive installation room. Ensure that access routes for equipment will accommodate the weights of the equipment and any transportation, lifting and rigging 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 27 of 77 https://device.report/manual/8787491 equipment. Ensure that all necessary arrangements for stopping and unloading on public or private property not belonging to the customer have been made. DIMENSIONS OF DELIVERY WITH DOLLY TRANSPORT EQUIPMEN T EQUIPM DIMENSIONS WEIGHT ENT LC GAN TRY LP GAN TRY LP RAIL S (BOX) LENGTH 2820 mm 111 in WIDTH 1230 mm 48.4 in HEIGHT 2000 mm 79 in LENGTH 2790 mm 109.8 in WIDTH 1135 mm 44.7 in HEIGHT 2152 mm 84.7 in LENGTH 6070 mm 239 in WIDTH 260 mm 10 in HEIGHT 300 mm 11.8 in 1060 kg 2340 lbs 1225 kg 2700 lbs 95 kg 209 lbs 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 28 of 77 https://device.report/manual/8787491 SHIPPING DOLLY FOR LP GANTRY The minimum door width needed (to accommodate the IGS Lateral shipping dolly) is 1135 mm [44.7 in] with the dolly stabilizers retracted. SHIPPING DOLLY FOR LC GANTRY Both ends of the dolly can be removed which will shorten the LC 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 29 of 77 https://device.report/manual/8787491 gantry dolly to 2300 mm [90 in], also the right and left top handles can be removed which will make the width 1160 mm [46 in]. STRUCTURAL NOTES All steel work and parts necessary to support ceiling-mounted tube hanger or other equipment are to be supplied by the customer or his contractors. The unistrut or equivalent structure should run continuous with no fittings extending below face of unistrut channel, run wall to wall, be parallel, square and in the same horizontal plane flush with finished ceiling. The system is to be cross braced vertically, horizontally and diagonally to allow no movement and a maximum of 1,58mm(1/16") deflection. (10) 12,7mm (1/2") dia. X 38,1mm (1 1/2") long bolts with unistrut 12,7mm (1/2") nuts with springs are to be provided by customer or his contractors for each stationary and auxillary support rail. Closure strips shall be provided for areas of unistrut exposed and without mounting units. Methods of support for the steelwork that will permit attachment to structural steel or through bolts in concrete construction should be favored. Do not use concrete or masonry anchors in direct tension. All units that are wall mounted or wall supported are to be provided with supports where necessary. Wall supports are to be supplied and installed by the customer or his contractors. See plan and detail sheets for suggested locations and mounting hole locations. All ceiling mounted fixtures, air vents, sprinklers, etc. To be flush 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 30 of 77 https://device.report/manual/8787491 mounted, or shall not extend more than 6,35mm (1/4") below the finished ceiling. Control walls with tube hanger passage above shall be constructed to 2130mm (7'-0") high. Floor slabs on which equipment is to be installed must be level to 3,17mm (1/8") in 3050mm (10'-0") Minimum floor thickness of 203mm (8"). Dimensions are to finished surfaces of room. The customers contractor must provide all penetrations in posttension floors. The customers contractor must provide and install any non-standard anchoring. Documents for standard anchoring methods are included with GE equipment drawings for geographic areas that require such documentation. Customers' contractor must provide and install hardware for "through the floor" anchoring and/or any bracing under access floors. This contractor must also provide floor drilling that cannot be completed because of an obstruction encountered while drilling by the GE installer such as rebar etc. It is the customer's responsibility to perform any floor or wall penetrations that may be required. The customer is also responsible for ensuring that no subsurface utilities (e.g., electrical or any other form of wiring, conduits, piping, duct work or structural supports (i.e. post tension cables or rebar)) will interfere or come in contact with 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 31 of 77 https://device.report/manual/8787491 subsurface penetration operations (e.g. drilling and installation of anchors/screws) performed during the installation process. To ensure worker safety, GE installers will perform surface penetration operations only after the customer's validation and completion of the "GE surface penetration permit" IF ACCESS IS NOT READILY AVAILABLE IT IS RECOMMENDED TO PROVIDE A TRAPDOOR IN THE CEILING TO ALLOW SERVICE ACCESS FOR CABLE MANAGEMENT. STRUCTURAL LAYOUT ITEM LIST LC GANTRY AND TABLE 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 32 of 77 https://device.report/manual/8787491 ANCHORING WITH NO BASEPLATE 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 33 of 77 https://device.report/manual/8787491 1. 1: LC baseplate mounting location: 12 bolts Pullout strength on each bolt 736 daN M20 Through-Bolts recommended (supplied by GE) Alternates: M16 Mechanical anchors (supplied by GE) Chemical anchors (not supplied by GE): HILTIHVU adhesive capsule + HAS Anchor rod 2. 2: Table mounting location: 4 bolts required Pullout strength on each bolt 4432 daN M20 Through-Bolts recommended (supplied by GE) Alternates: M16 Mechanical anchors (supplied by GE) Chemical anchors (not supplied by GE): HILTIHVU adhesive capsule + HAS Anchor rod 3. 2b: Alternate bolt holes for seismic zones 1 and 2 FLOOR REQUIREMENTS AND CABLE MANAGEMENT 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 34 of 77 https://device.report/manual/8787491 FLOOR REQUIREMENTS The maximum pullout force per GE supplied anchor was calculated assuming : A concrete compression strength of 17.24 MPa at 28 days (which is the minimum required compression stength). Anchors installed to the required hole depth of 165.1 mm [6.5 in] minimum. Center of anchor hole to concrete edge distance 79.4 mm [3.1 in]. Make sure to obtain data on compression strength of the concrete before using floor anchors. The floor slab on which the equipment is to be installed must be flat and level (1 mm [0.04 in]/1 m [40 in] where equipment is installed and 5 mm [0.2 in]/2 m [79 in] general levelness). Anchoring to the floor is intended to the structural elements and not to common screed. 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 35 of 77 https://device.report/manual/8787491 Do not glue the floor covering in the gantry zone. JUNCTION BOX BELOW FLOOR NOTE: PIPE, JUNCTION BOX AND DUCT OR CONDUIT ARE TO BE SUPPLIED AND IS TO BE INSTALLED BY CUSTOMER OR CUSTOMER'S CONTRACTOR. XT RADIOGRAPHIC SUSPENSION, INBOARD MOUNTING 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 36 of 77 https://device.report/manual/8787491 Structural Support system is not supplied or installed by GE Healthcare DETAIL 1 DETAIL 2 MAVIG SUSPENSION MOUNTING METHOD 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 37 of 77 https://device.report/manual/8787491 Weight up to: 94 kg [207 lb] (75 kg [165 lb] system + 19 kg [42 lb] track) The required factor of safety is "4" for attaching to Unistrut or equivalent rails and "6" for attaching to the concrete ceiling. CONSULT MAVIG INSTALLATION MANUAL REV: POR03001 TO DESIGN AND MOUNT THE CEILING SUPPORT. SUSPENSION COLUMN LENGTHS AND INSTALLATION DETAILS MONITOR SUSPENSION RAIL MOUNTING SPECIFICATIONS 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 38 of 77 https://device.report/manual/8787491 CEILING SUSPENSION DISCLAIMER Safety and precautionary comments Only qualified, licensed technicians can perform electrical connections, installation, removal and repair. It is strongly recommended that at least two persons perform the installation. Installing the system: Prior to installation, a structural engineer must confirm that the mounting structure is strong enough to provide proper support for the entire system and any attached end devices. Installation must be completed according to local building codes. Determination of required installation hardware and torque values for installation of the ceiling column and ceiling track is the sole responsibility of the structural engineer. Ceiling mounted systems must be installed properly. Failure to follow the instructions provided may lead to a potentially dangerous and unstable condition of the system. GE and/or MAVIG is not responsible for unauthorized modifications made to the system or use of the system for unintended purposes. GE and/or MAVIG cannot be held liable for improper operation and 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 39 of 77 https://device.report/manual/8787491 modifications. Since improper modifications may impair proper operation, safety or reliability of the system, product modifications require written authorization from MAVIG. Under GE responsibility or under Customer responsibility, for all pre-installations, whatever is the supporting structure (bridge, chair, Unistrut channel, other channels, direct anchorage in concrete, transversal beam, etc. …) a certificate must be obtained from a structural engineer. This certificate shall include the definition of fasteners and of their tightening torque, especially for the non-standard cases described in MAVIG PIM and for which the standard anchoring/screws delivered with product shall not be used but shall be defined (and implemented in most cases) by the structural company. WARNING: It is prohibited to alter the length of the ceiling column or remove any securing screws. LOCATION OF LATERAL POSITIONER AND MONITOR SUSPENSION RAILS- SECTION MONITORS CENTERED 1 Monitor suspension axis 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 40 of 77 https://device.report/manual/8787491 2 Monitor cable suspension axis 3 Lateral positioner rail axis 4 Lateral positioner cable suspensi on axis Note: no mounting hardware can protrude below the finished ceiling height (top surface of lateral positioner stationary rails), such as Unist rut mounting bolts, support brackets, sprinklers, air vents etc. in betw een LP stationary rails LATERAL POSITIONER RAIL MOUNTING SPECIFICATIONS WARNING: STRUCTURE SHOULD NOT ALLOW VIBRATIONS TRANSMISSION EQUAL OR LOWER THAN 10Hz CAUTION 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 41 of 77 https://device.report/manual/8787491 The maximum load per bolt will not exceed 1912 N [430 lb]. Each bolt must not "pull out" otherwise fail under a vertically downward "dead" load of 7633 N [1717 lb]. OTS SUSPENSION RAILS MOUNTING SPECIFICATIONS Distance between holes axis 660.4 mm [26 in], Maximum load per screw is 155.7 daN [350 lb], however each mounting screw must not "PULL OUT" or otherwise fail under a vertically downward dead load of 622.8 daN [1400 lb]. Bolts for mounting stationary rails on structural supports supplied by GE (1/2" - 13 headed bolts) TEMPERATURE AND HUMIDITY SPECIFICATIONS IN-USE CONDITIONS EXAM ROOM CONTROL ROO TECHNICAL RO 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 42 of 77 https://device.report/manual/8787491 M Temperatur Min e Rec Ma om x Min OM Rec Ma om x Min Rec Ma om x me me me nde nde nde d d d 15 22 32 15 22 35 10 ° 18 ° 32 ° °C °C °C °C °C °C C [5 C [6 C [9 [59 [72 [90 [59 [72 [95 0° 4° 0° °F] °F] °F] °F] °F] °F] F] F] F] Temperature ≤ 10 °C/h [50 °F ≤ 10°C/h [50 °F/ ≤ 10 °C/h [50 °F gradient /h] h] /h] Relative hum 30% to 70% 30% to 75% 30% to 75% ≤ 10%/h ≤ 10%/h ≤ 10%/h idity (1) Humidity gra dient STORAGE CONDITIONS Temperature +10 °C [50 °F] to +40 °C [104 °F] Relative humidity (1) 10% to 80% 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 43 of 77 https://device.report/manual/8787491 Material should not be stored for more than 90 days. (1) Non-condensing AIR RENEWAL According to local standards. NOTE: In case of using air conditioning systems that have a risk of water leakage it is recommended not to install it above electric equipment or to take measures to protect the equipment from dropping water. HEAT DISSIPATION RO DESCRIPTION OM Ex amin ation room LC Gantry / LP Gant HEAT DISSIPATIO HEAT DISSIPATIO N (kW) N (BTU/hr) STA AVE MA STA AVE MA ND RAG X ND RAG X BY E* BY E* 0.61 1.21 207 412 551 6 8 7 170 170 170 6 6 6 1.62 ry Patient table Large Display Moni tor (LDM) 0.50 0.50 0.50 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 44 of 77 https://device.report/manual/8787491 Typical injector 0.09 0.09 0.09 320 320 320 TOTAL 1.20 1.80 2.21 410 615 754 2 4 3 DL user area with 1 0.16 0.16 0.16 546 546 546 - - 1.00 - - 341 TFT monitor Advantage Worksta tion (AW) Additional LCD mo 2 0.12 0.12 0.12 409 409 409 0.28 0.28 1.28 79'- 79'- 363 7" 7" '-1 nitor(s) TOTAL 1" C1 Frontal cabinet 0.71 1.29 1.59 T echni cal ro C1 Lateral cabinet 0.31 0.86 1.16 242 441 543 1 2 5 105 294 396 7 6 9 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 45 of 77 om C2 Cabinet 0.29 Coolix 4100 chiller Frontal & Lateral @ https://device.report/manual/8787491 1.34 4.6 6.8 1.81 989 12. 457 617 1 1 15 23 42 4 8 60 832 474 991 0.12 0.14 0.18 410 478 614 0.42 0.42 0.42 141 141 141 8 8 8 221 221 221 6 6 6 125 125 125 7 7 7 125 125 125 7 7 7 341 341 341 2 2 2 60Hz (x2) Chiller autotransfor mer @60Hz(x2) Detector condition er (x2) Power Distribution 0.6 0.65 0.65 Box (PDB) UPS 3 KVA UPS 3 KVA for LDM LD cabinet 0.37 0.37 1.00 0.37 0.37 1.00 0.37 0.37 1.00 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 46 of 77 Fluoro UPS UL TOTAL 1.38 https://device.report/manual/8787491 1.38 1.38 472 472 472 0 0 0 10.2 14.7 21.5 291 418 612 1 0 3 5'- 0'- 1'- 9" 1" 8" WARNING The list contains only the principal components of the system and doesn't contain any non-GE supplied equipment. This average corrisponds to 11 cases in 10 hours. ELECTRICAL NOTES All wires specified shall be copper stranded, flexible, thermo-plastic, color coded, cut 10 foot long at outlet boxes, duct termination points or stubbed conduit ends. All conductors, power, signal and ground, must be run in a conduit or duct system. Electrical contractor shall ring out and tag all wires at both ends. Wire runs must be continuous copper stranded and free from splices. 1. Aluminum or solid wires are not allowed. 2. Wire sizes given are for use of equipment. Larger sizes may be required by local codes. 3. It is recommended that all wires be color coded, as required in accordance with national and local electrical codes. 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 47 of 77 https://device.report/manual/8787491 4. Conduit sizes shall be verified by the architect, electrical engineer or contractor, in accordance with local or national codes. 5. Convenience outlets are not illustrated. Their number and location are to be specified by others. Locate at least one convenience outlet close to the system control, the power distritbution unit and one on each wall of the procedure room. Use hospital approved outlet or equivalent. 6. General room illumination is not illustrated. Caution should be taken to avoid excessive heat from overhead spotlights. Damage can occur to ceiling mounting components and wiring if high wattage bulbs are used. Recommend low wattage bulbs no higher than 75 watts and use dimmer controls (except MR). Do not mount lights directly above areas where ceiling mounted accessories will be parked. 7. Routing of cable ductwork, conduits, etc., must run direct as possible otherwise may result in the need for greater than standard cable lengths (refer to the interconnection diagram for maximum usable lengths point to point). 8. Conduit turns to have large, sweeping bends with minimum radius in accordance with national and local electrical codes. 9. A special grounding system is required in all procedure rooms by some national and local codes. It is recommended in areas where patients might be examined or treated under present, future, or emergency conditions. Consult the governing electrical code and confer with appropriate customer administrative personnel to 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 48 of 77 https://device.report/manual/8787491 determine the areas requiring this type of grounding system. 10. The maximum point to point distances illustrated on this drawing must not be exceeded. 11. Physical connection of primary power to GE equipment is to be made by customers electrical contractor with the supervision of a GE representative. The GE representative would be required to identify the physical connection location, and insure proper handling of GE equipment. 12. GEHC conducts power audits to verify quality of power being delivered to the system. The customer's electrical contractor is required to be available to support this activity. All junction boxes, conduit, duct, duct dividers, switches, circuit breakers, cable tray, etc., are to be supplied and installed by customers electrical contractor. Conduit and duct runs shall have sweep radius bends Conduits and duct above ceiling or below finished floor must be installed as near to ceiling or floor as possible to reduce run length. Ceiling mounted junction boxes illustrated on this plan must be installed flush with finished ceiling. All ductwork must meet the following requirements: 1. Ductwork shall be metal with dividers and have removable, accessible covers. 2. Ductwork shall be certified/rated for electrical power purposes. 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 49 of 77 https://device.report/manual/8787491 3. Ductwork shall be electrically and mechanically bonded together in an approved manner. 4. PVC as a substitute must be used in accordance with all local and national codes. All openings in raceway and access flooring are to be cut out and finished off with grommet material by the customers contractor. General contractor to insert pull cords for all cable run conduits between the equipment room and the operators control room. 10 foot pigtails at all junction points. Grounding is critical to equipment function and patient safety. Site must conform to wiring specifications shown on this plan. CONNECTIVITY REQUIREMENTS Your new GE Healthcare imaging modality will require local and remote connectivity to enable our full range of digital support: Local connectivity: This allows your system to connect to local devices such as PACS and modality worklist. We will require network information to configure the system(s), and a live ethernet port(s) prior to the delivery of the system(s). Remote connectivity: Your GE Healthcare service warranty includes InSite™ (applicable to InSite capable products), a powerful broadband-based service which enables digital tools that can help guard your hospital against equipment downtime and revenue loss 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 50 of 77 https://device.report/manual/8787491 by quickly connecting you to a GE Healthcare expert. Depending on product family and software version, imaging systems can be connected in one of the following methods: 1. TLS over TCP Port 443 (Preferred method for new products) via: DNS resolution Customer-provided Proxy or GE Proxy (Available in some regions) 2. Site-to-Site IPsec VPN tunnel Please provide the GE project manager with the contact information for the resource that can provide information required to set up these connections. GEHC will send out communication to these contacts, which will include the project's Connectivity requirements, and a Connectivity form. This form will need to be completed and returned to GEHC prior to delivery of the system to ensure the system is tested and connectivity is enabled prior to the completion of the installation. 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 51 of 77 https://device.report/manual/8787491 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 52 of 77 IT https://device.report/manual/8787491 ELECTRICAL LAYOUT ITEM LIST E M 1 24" x 24" x 12" [600 x 600 x 300] Box below floor, (1) 6" [150] di a. suitable length threaded pipe, (2) 6" [150] dia. locknuts and (4) 1" [25] dia. locknuts. (LC g antry) 2 (1) GE supplied fitting. (1) 12" x 12" x 6" [300 x 300 x 150] Box, (1) 6" [150] dia. bushing, (4) 1" [25] dia. bushing for water lines (LC Gantry) 3 4"x4"x4" [100 x 100 x 100] flush wall junction box 12" [300] belo w finished ceiling (x-ray buzzer) 4 Empty 3" [75] conduit below floor for waterlines (LC chiller) 5 10" x 3 1/2" [250 x 89] surface wall duct with minimum 2 divider s 6 18" x 3 1/2" [450 x 89] surface wall duct with minimum 2 divider s 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 53 of 77 https://device.report/manual/8787491 7 8" x 8" x 6" [200 x 200 x 150] box under table (PDM/TRAM) 8 8" x 8" x 6" [200 x 200 x 150] box below floor (patient monitorin g equipment) 9 Local service disconnect (LOTO) 10 Power Distribution Box 11 10" x 3 1/2" [250 x 89] below floor duct with minimum 2 divider s 12 18" x 3 1/2" [450 x 89] below floor duct with minimum 2 divider s 13 18" x 3 1/2" [450 x 89] above ceiling duct with minimum 2 divid ers 14 10" x 3 1/2" [250 x 89] above ceiling duct with minimum 2 divid ers 15 6" x 4" [150 x 100] riser duct from duct below to 1" [13] above fi nished floor with minimum 1 2 divider 16 18" x 3 1/2" [250 x 89] vertical duct from duct above ceiling to fi nished ceiling with minimum 2 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 54 of 77 https://device.report/manual/8787491 dividers 17 6"x6"x6" [150 x 150 x 150] flush ceiling box for waterlines (LP ga ntry) 18 6"x6"x6" [150 x 150 x 150] flush ceiling box for waterlines (LP chi ller) Electrical Outlet Legend Additional Conduit Runs Additional Conduit Runs (Contractor Supplied and Installed) From (B To (Bubble # / Item) Qty ubble # / Usable le Size (in) ngth Item) 18 LAT 17 LAT Gant 1 59 ft. 3 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 55 of 77 Water Lin https://device.report/manual/8787491 ry e 4 AP 2 1 59 ft. 3 Warning light 1 - 12 6 1 - 12 120-V 1 phase power 1 - As Req'd Spooler 1 - As Req'd 120-V 1 phase power 1 - As Req'd Spooler 1 - Cables Water Lin AP Gantr y e Light Sig naling Co ntrol Box Light Sig naling Co C2 Cabin et ntrol Box Light Sig naling Co ntrol Box LED Trans former LED Trans former LED Lam 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 56 of 77 https://device.report/manual/8787491 p come wit h spooler 3 X-R 6 1 90 ft. 11 2 1 90 ft. 11 2 2 - 3 2 68 ft. As Req'd Emergency off 1 - 12 Emergency off 1 - 12 ay Buzzer 3 X-R net 5 ay Buzzer 6 Larg C1F Cabi Control R oom 7 e Displa TRAM/P DM y Cabinet 10 Po wer Distri 6 20 kVA U PS bution B ox 10 Po wer Distri bution B ox 10 Po 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 57 of 77 https://device.report/manual/8787491 wer Distri bution B ox 10 Po 6 wer Distri C1F Cabi 2 68 ft. 21 2 2 68 ft. 11 2 1 68 ft. 11 2 1 68 ft. As Req'd 2 68 ft. 21 2 net bution B ox 10 Po 6 wer Distri C1F Cabi net bution B ox 10 Po 6 wer Distri C2 Cabin et bution B ox 10 Po 6 wer Distri C2 Cabin et bution B ox 10 Po wer Distri 6 C1L Cabi net 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 58 of 77 https://device.report/manual/8787491 bution B ox 10 Po 15 Table (Ta wer Distri ble Powe bution B r) 1 - Req'd ox 9 LOT 2; As 480-V 3 phase power 1 - As Req'd 10 1 - As Req'd 1 - 3 2 - 3 O Discon nect 9 LOT Power Di O Discon stribution nect Box 5 Pati 16 Monitor ent Moni Bridge / toring Co Boom nsole 8 Pati ent Moni 7 TRAM/P DM toring Co nsole 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 59 of 77 https://device.report/manual/8787491 POWER REQUIREMENTS POWER SUPPLY 3 PHASES+N+G 380/400/415/480 V ±1 0% FREQUENCIES for 380/400 50/60 Hz ± 3 Hz /415 V FREQUENCY for 480 V 60 Hz ± 3Hz MAXIMUM INPUT POWER 150 kVA (0.1 sec max) NOMINAL LOAD (at 125 k 60 kVA V, 100 ms, 640 mA): MAXIMUM LINE RESISTAN 380 V : 0.09 Ω / 400 V : 0.096 Ω / 415 V : CE PER 2 PHASES WIRES 0.102 Ω / 480 V : 0.12 Ω (Ohm) An EMI filter, provided by GE, is inside the PDB when Fluoro UPS CE is used. Neutral is mandatory for UPS control. TNS neutral point connection must be used. In case of IT or delta configuration without neutral, an isolation transformer is needed (supplied by customer) 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 60 of 77 https://device.report/manual/8787491 Three-phase, 5 conductors (3 phase conductors, 1 neutral and 1 protective earth conductor) Power supply should come into a power distribution box (PDB) containing the protective units and controls. The section of the supply cable should be calculated in accordance with its length and the maximum line resistance per 2 phases. SUPPLY CHARACTERISTICS Power input must be separated from any others which may generate transients (elevators, air conditioning, radiology rooms equipped with high speed film changers ...) All equipment installed with IGS system components must be powered separately (e.g. lighting, power outlets) Transients must be less than 2,000 V peak in common mode and 1,000 V in differential mode, with a duration limited to a few microseconds. GROUND SYSTEM At least 35mm² copper from main ground point to the PDB. The equipotential link will be by means of an equipotential bar. This equipotential bar should be connected to the protective earth conductors in the ducts of the non IGS cableways and to additional equipotential connections linking up all the conducting units in the 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 61 of 77 https://device.report/manual/8787491 rooms where IGS units are located. CABLES Power and cable installation must comply with the distribution diagram. All cables must be isolated and flexible, cable color codes must comply with standards for electrical installation. The cables from signalling and remote control (Y, SEO, L...) will go to PDB with a pigtail lenght of 1.5 m, and will be connected during installation. Each conductor will be identified and isolated (screw connector). CABLEWAYS The general rules for laying cableways should meet the conditions laid down in current standards and regulations, with regard to : Protecting cables against water (Cableways should be waterproof), Protecting cables against abnormal temperatures (Proximity to heating pipes or ducts), Protecting cables against temperature shocks, Replacing cables (Cableways should be large enough for cables to be replaced) , Only GE cables are running inside cableways, Metal cableways should be grounded. 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 62 of 77 https://device.report/manual/8787491 MANDATORY LOTO REQUIREMENTS Core system: A wall circuit breaker or equivalent device with LOTO capability must be installed on the mains line to the PBD. This device must be compatible with the power input specifications of the system. The customer is responsible for the procurement, delivery and installation of this breaker. LDM option: A wall circuit breaker or equivalent device with LOTO capability must be installed on the mains line to the LDM UPS. The rating of this device shall be 30A for UL and 16A for CE configurations. The customer is responsible for the procurement, delivery and installation of this breaker. TYPICAL EQUIPOTENTIAL CONNECTIONS 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 63 of 77 https://device.report/manual/8787491 POWER DISTRIBUTION L X-Ray room warning light control panel L1 XRay ON light - 24V SEO1-2 Emergency OFF button with two normally closed (NC) contacts (1) RL Room light circuit: room lights off during X-Ray generation BR Injector wall outlet 10/16A+G 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 64 of 77 https://device.report/manual/8787491 (1) Location and/or quantity: refer to layout NOTES: Max size of terminal block for PDB input cables: 4x3/0 AWG FEEDER TABLE MIN. FEEDER WIRE SIZE, AWG OR MC M (sq. mm)/VAC 480 VAC MINIMUM FEEDER WIRE LENGTH - ft (m) 50 100 150 200 250 300 350 400 (15) (30) (46) (61) (76) (91) (10 (12 7) 2) *1/ *1/ *1/ 1/0 3/0 4/0 4/0 300 0 (5 0 (5 0 (5 (55) (85) (10 (10 M 5) 5) 5) 7) 7) (15 0) GENERAL NOTES IN ALL CASES QUALIFIED PERSONNEL MUST VERIFY THAT THE FEEDE R (AT THE POINT OF TAKE-OFF) AND THE RUN TO THE GE SYSTEM M EET ALL THE REQUIREMENTS STATED IN THE PIM FOR A SINGLE UNIT INSTALLATION, THE MINIMUM TRANSFORMER S IZE IS 225KVA, WITH 2.4% RATED REGULATION AT UNITY POWER FAC TOR. RESULTANT MAXIMUM ALLOWABLE FEEDER REGULATION IS 3. 6% 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 65 of 77 https://device.report/manual/8787491 THE GROUND WIRE TO EARTH SHALL BE A MINIMUM OF AWG #2 (U L) OR 35 MM² (CE) OR THE SAME SIZE (100%) AS FEEDER WIRES, WHI CH EVER IS LARGER. WHEN A FLUORO UPS IS OR WILL BE INSTALLED, A NEUTRAL LINE IS MANDATORY. IF IT SCHEME AS EARTHING SYSTEM IS USED, AN ISOL ATION TRANSFORMER IS REQUIRED WITH DELTA-WYE OR DELTA-STA R CONNECTION. * MINIMUM WIRE SIZE FOR CIRCUIT BREAKER, BASED ON RECOMME NDED OVERCURRENT PROTECTION. INTERCONNECTIONS 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 66 of 77 https://device.report/manual/8787491 A mandatory component of this drawing set is the GE Healthcare PreInstallation manual. Failure to reference the Pre Installation manual will result in incomplete documentation required for site design and preparation. Pre Installation documents for GE Healthcare products can be accessed on the web at: www.gehealthcare.com/siteplannin GE does not take responsibility for any damages resulting from changes on drawings made by others. Errors may occur by not referring to the complete set of final issue drawing. GE cannot accept responsibility for any damage due to the partial use of GE final issue drawings, however 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 67 of 77 https://device.report/manual/8787491 caused. All dimensions are in millimeters unless otherwise specified. Do not scale from printed pdf files. GE accepts no responsibility or liability for defective work due to scaling from these drawings. Documents / Resources GE Healthcare INNOVA IGS 620-630 Interventional Neuro radiology [pdf] Instruction Manual INNOVA IGS 620-630 Interventional Neuroradiology, INN OVA IGS 620-630, Interventional Neuroradiology, Neuror adiology References Site Planning - Support | GE HealthCare (United States) Documents - ge-healthcare,ge healthcare – INNOVA IGS 620-630 [pdf] D Documents and Settings All Users Application Data Aut odesk RAC 2011 Imperial Templates Annotations 5 114R S heet A 1 INNOVA IGS 620 630 RENDERING 212058015 GE HC SP www3 gehealthcare ~ media us support site planni ng interventional gehc sp igs 114r ||| GE Healthcare has made reasonable efforts to ensure this BIM file conforms to requirements 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 68 of 77 https://device.report/manual/8787491 of the applicable pre-installation manual. This BIM file was produced to assist with site planni ng and is not intended for construction or final building modeling. GE Healthcare is not respo nsible for any dama... lang:en score:44 filesize: 225.78 K page_count: 3 document date: 2012-08-21 [pdf] C Users 502673615 Documents 4 72 GEHC SP IGS 630 72R gehealthcare jssmedia documents us global support site p lanning interventional imaging innova igs 6x0 gehc sp 72r rev 1 hash A5776D558BCD6D7F6B1CCEE42B44C1EA ||| GE Healthcare Project Management GE Health care has made reasonable efforts to ensure thi s BIM file conforms to requirements of the app licable pre-installation manual. This BIM file wa s produced to assist with site planning and is n ot intended for construction or final building modeling. GE Healthca... lang:en score:33 filesize: 1.73 M page_count: 4 document date: 2017-01-24 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 69 of 77 [pdf] User Manual https://device.report/manual/8787491 Documentation E6 Interconnections GEHC SP IGS 630 4 72F gehealthcare s g jssmedia de4507ae2f594b12b563d972f68b24a3 la en ||| TYPICAL ---- ---- REV DATE MODIFICATIONS 0 1 - C1 - Cover Sheet 02 - C2 - Disclaimer - Site Rea ... ucts can be accessed on the web at: ww w.gehealthcare.com/siteplanning GE Healthcar e Drawn by PMM INNOVA IGS 620-630 FINA L STUDY Verified by Concession S.O. GON TST - - GE does not take resp... lang:en score:32 filesize: 2.27 M page_count: 2 2 document date: 2022-07-13 [pdf] User Manual Documentation E6 Interconnections GEHC SP IGS 620 5 114F gehealthcare ca jssmedia documents us global support site planning int erventional imaging innova igs 6x0 gehc sp 114f rev 1 has h 39287F231651918D4856137BE51A6B66 ||| TYPICAL ---- ---- REV DATE MODIFICATIONS 0 1 - C1 - Cover Sheet 02 - C2 - Disclaimer - Site Rea ... ucts can be accessed on the web at: ww w.gehealthcare.com/siteplanning GE Healthcar e Drawn by PMM INNOVA IGS 620-630 FINA L STUDY Verified by Concession S.O. GON TST 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 70 of 77 https://device.report/manual/8787491 - - GE does not take resp... lang:en score:32 filesize: 2.2 M page_count: 22 document date: 2023-05-17 [pdf] User Manual Documentation E6 Interconnections GEHC SP IGS 620 5 114F gehealthcare ca jssmedia documents us global support site planning int erventional imaging innova igs 6x0 gehc sp 114f rev 1 has h 39287F231651918D4856137BE51A6B66 ||| TYPICAL ---- A 06/Dec/2018 Final study based on DC- ---- REV DATE MODIFICATIONS 01 - C 1 - Co ... ucts can be accessed on the web at: w ww.gehealthcare.com/siteplanning GE Healthc are Drawn by PMM INNOVA IGS 620-630 FIN AL STUDY Verified by Concession S.O. GON TS T - - GE does not take resp... lang:en score:31 filesize: 2.15 M page_count: 2 2 document date: 2022-03-17 [pdf] User Manual Documentation E6 Interconnections GEHC SP IGS 620 5 114F gehealthcare jssmedia documents us global support site planning interv entional imaging innova igs 6x0 gehc sp 114f rev 1 hash 3 9287F231651918D4856137BE51A6B66 ||| TYPICAL ---- A 06/Dec/2018 Final study based 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 71 of 77 https://device.report/manual/8787491 on DC- ---- REV DATE MODIFICATIONS 01 - C1 - Co ... ucts can be accessed on the web at: ww w.gehealthcare.com/siteplanning GE Healthcar e Drawn by PMM INNOVA IGS 620-630 FINA L STUDY Verified by Concession S.O. GON TST - - GE does not take resp... lang:en score:30 filesize: 2.24 M page_count: 2 2 document date: 2021-09-24 [pdf] User Manual Documentation E6 Interconnections GEHC SP IGS 6X0 5 122F gehealthcare jssmedia documents us global support site planning interv entional imaging innova igs 6x0 gehc sp 122f rev 1 hash E 0BCB14B99DB0C13CA453FE3CAE213C9 ||| TYPICAL ---- A 23/Sep/2019 Initial release per PIM revision 3 ---- REV DATE MODIFICATIONS 01 ... ucts can be accessed on the web at: www. gehealthcare.com/siteplanning GE Healthcare Drawn by RET INNOVA IGS 620-630 FINAL ST UDY Verified by Concession S.O. GON TST - GE does not take resp... lang:en score:30 filesize: 2.18 M page_count: 2 2 document date: 2021-12-10 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 72 of 77 [pdf] User Manual https://device.report/manual/8787491 Documentation Accessories Catalog US Catalog GE Healthcare U S Accessories Optional record er prints ECG strips on demand for manual review Touchsc reen Operation trophon Sonex HL 6 bottles box 80 ml bott le system reliability Operations included to supplement UP S documentation UL HL™ E8350MC The cartridge contain s a proprietary solution of ts us global products accesories supplies new docs accessories catalog916cma gehealthcar e media d9410ff1f36544ff940922f80cccc1bf Ceiling mount configurations require catalog E8007PJ OCS III mounting p late 100 kVA Bypass Panel Use with E4502FB latam jssmedi a la es pa widen gehealthcarecom migrated rev f84fc8b29 42840a3ad1bad694377efe0 hash 7ACCCB43C0F63963E8A F71773B8FC0A3 1 ||| GE Healthcare Accessories Supplies U. S. Catal og CT, PET/CT MR Nuclear Medicine Ultrasoun d X-ray Mammography Power Quality Adventu re Series This catalog is searchable using contr ol F on a PC or command F on a Mac. Rev. 01/ 21 JB00708US Save time. Order accessories onl ine with Service Sh... lang:en score:28 filesize: 23.84 M page_count: 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 73 of 77 https://device.report/manual/8787491 308 document date: 2021-01-14 [pdf] Section 1 Introduction GEMS ography acquisition systems gehc ihe integration innova igs 620 630 5458749 8en rev2 latam gehealthcare jssmedia widen gehealthcarecom migr ated rev b1890f5a5c7d44bb96ca4c9a6bd3f493 hash 7FA1 55CA3905C8C94AB7FE3E23E51123 ||| GE Healthcare InnovaTM IGS 620, 630 Integrati ng the Healthcare Enterprise IHE Integration St atement 5458749-1-8EN Rev 2 2012, General E lectric Company, All Rights Reserved IHE Integr ation Statement 5458749-1-8EN / rev 2 Revisio n History Date Part/Rev January 10, 2012 5458 749-1-8EN rev 1 C... lang:en score:27 filesize: 124.87 K page_count: 5 document date: 2012-03-22 [pdf] Integrating the Healthcare Enterprise IHE Integration State ment ConnectPro HIS RIS DICOM conformance statement William Balloni GE Yokogawa Medical Systems ography ac quisition systems gehc ihe integration innova igs 620 630 5714994 1 8en rev2 gehealthcare jssmedia widen gehealth carecom migrated rev hash C5209FB8921DFEF5BA337912 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 74 of 77 https://device.report/manual/8787491 2C677C0D ||| Technical Publications GE Healthcare 57149941-8EN Revision 2 InnovaTM IGS 620, InnovaTM IGS 630 Integrating the Healthcare Enterprise I HE Integration Statement Copyright 2016 by G eneral Electric Company Revision History Date Part/Rev November 23, 2015 5714994-1-8EN r ev 1 Change Descrip... lang:en score:26 filesize: 56.46 K page_count: 6 document date: 2016-02-26 [pdf] Accessories Catalog U S Accessories Supplies XrayInterventionalImaging US Ca talog ChapterJuly 2021JB00644US gehealthcare jssmedia gehc us images products imaging accessories xrayinterven tionalimaging supplies catalog chapterjuly 2021jb00644us rev 1 ||| GE Healthcare XR X-ray U.S. Accessories Suppli es Rev. 07/21 JB00644US XR How to Order Sho p online: gehealthcare.com/accessories Availab le 24/7, GE Healthcare Service Shop makes ord ering supplies online fast and easy. Search real -time inventory of compatible, OEM products T ake advantage of Auto R... 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 75 of 77 https://device.report/manual/8787491 lang:en score:26 filesize: 4.11 M page_count: 6 6 document date: 2021-07-30 [pdf] Accessories Catalog Xray Accessories Supplies US Catalog Chapter 2016916JB3 9292USg1 latam gehealthcare jssmedia files x xray accesso ries supplies us catalog chapter 2016916jb39292usg1 rev bff463cf70b54945a9d08794ddaec654 hash CF5FCA6611B8 C000E3F8BBD68C0BA796 ||| GE Healthcare XR X-ray U.S. Accessories Suppli es Rev. 01/21 JB00644US XR How to Order Sho p online: gehealthcare.com/accessories Availab le 24/7, GE Healthcare Service Shop makes ord ering supplies online fast and easy. Search real -time inventory of compatible, OEM products T ake advantage of Auto R... lang:en score:26 filesize: 4.29 M page_count: 6 6 document date: 2021-01-14 12/10/2023, 11:08 PM GE Healthcare INNOVA IGS 620-630 Interventional Neuroradiology In... 76 of 77 [pdf] Accessories https://device.report/manual/8787491 Catalog Imaging Accessories Supplies US CatalogJuly 2021JB00708 US gehealthcare media GEHC Files Products rev a0c8610c b6cc4e7880fbbbd58f68bc5a ||| GE Healthcare Accessories Supplies U. S. Catal og CT, PET/CT MR Nuclear Medicine Ultrasoun d X-ray Mammography Power Quality Adventu re Series This catalog is searchable using contr ol F on a PC or command F on a Mac. Rev. 07/ 21 JB00708US Save time. Order accessories onl ine with Service Sh... lang:en score:19 filesize: 26.68 M page_count: 308 document date: 2021-08-17 [pdf] Documentation interoperability dicom xray gehc conformance innovaigs62 0 630 5435421 1 8en rev2 gehealthcare jssmedia widen ge healthcarecom migrated rev hash AC19A30FE290720B316 2EC6E21CE8B95 ||| GE Healthcare InnovaTM IGS 620, 630 Confor mance Statement of DICOM OPERATING DOC UMENTATION 5435421-1-8EN Revision 2 GE H ealthcare InnovaTM IGS 620, 630 Conformance Statement of DICOM Direction 5435421-1-8E 12/10/2023, 11:08 PM N, Revision 2 2 GE Healthcare InnovaTM IGS 6 20, 630 Conformance Statement of DICOM Dir ec... lang:da score:17 filesize: 1.31 M page_count: 1 50 document date: 2012-06-01 tags: GE Healthcare, INNOVA IGS 620-630, INNOVA IGS 620-630 Interventional Neuroradiology, Interventional Neuroradiology, Neuroradiology, Search Any Device: