IMR Test Labs - Portland • 5687-A SE International Way • Portland, OR 97222 TEST REPORT IMR Report Number 202001831 SUMMARY Two samples were received for metallurgical analysis. February 10, 2020 The samples meet the customer macrostructure requirements. The grain size results are also reported. MACROSTRUCTURE EVALUATION PO Number P0021070 Date Received February 5, 2020 Material A286 S/Steel Material Identity Reference: S0025329 Specification(s) Customer Requirements Laboratory Number Macrostructure Sample ID The macrostructure is homogenous with no evidence 1.00” X 0.75” X 4.00” GR; of segregation, blowhole, 01831-1MAC Heat# 61869-1V; pipes/cracks, de-cohesion, (ID: D) inclusions, or any other defects The macrostructure is homogenous with no evidence 1.00” X 1.00” X 4.00” GR; of segregation, blowhole, 01831-2MAC Heat# 59762-6; pipes/cracks, de-cohesion, (ID: B) inclusions, or any other defects Structure and grain have to be homogenous, with no indication of segregation, Customer blowhole, crack, de-cohesion, Requirements inclusion or any other nonconformance that would lead to the rejection of material. Etchant(s): Hot (160-180°F): 25%H2O+50%HCl(37%)+25%HNO3(69%) Magnification(s): Visual-20X Method(s): ASTM E340-15 Reviewed by Alex N. Fish Metallurgy & Chemistry Manager All procedures were performed in accordance with the IMR Quality Manual, current revision, and related procedures; and the P&W MCL Manual F-23 and related procedures as applicable. The information contained in this test report represents only the material tested and may not be reproduced, except in full, without the written approval of IMR Test Labs (“IMR”). IMR maintains a quality system in compliance with the ISO/IEC 17025 and is accredited by A2LA, certificate #1140.07. IMR will perform all testing in good faith using the proper procedures, trained personnel, and equipment to accomplish the testing required. Conformance will be based on results without measurement uncertainty applied, unless otherwise requested by the customer. IMR’s liability to the customer or any third party is limited at all times to the amount charged for the services provided. All test samples will be retained for a minimum of 3 months and may be destroyed thereafter, unless otherwise specified by the customer. The recording of false, fictitious, or fraudulent statements or entries on this document may be punished as a felony under federal statutes. IMR Test Labs is a GEAE S-400 approved lab (Supplier Code T4280). Page 1 of 3 IMR PTL #202001831 IMR Test Labs - Portland • 5687-A SE International Way • Portland, OR 97222 ASTM MICRO GRAIN SIZE Laboratory Number Typical 01831-1MET G1.5 01831-2MET G3.5 Sample ID 1.00” X 0.75” X 4.00” GR; Heat# 61869-1V; (ID: D) 1.00” X 1.00” X 4.00” GR; Heat# 59762-6; (ID: B) Samples were examined at 100X magnification Etchant: Kalling’s Method(s): ASTM E112-13 Figure 1: Macro photograph of Heat# 61869-1V (01831-1MAC) showing structure and grain. Hot (160-180°F): 25%H2O+50%HCl(37%)+25%HNO3(69%). Figure 2: Macro photograph of Heat# 59762-6 (01831-2MAC) showing structure and grain. Hot (160-180°F): 25%H2O+50%HCl(37%)+25%HNO3(69%). Page 2 of 3 IMR PTL #202001831 IMR Test Labs - Portland • 5687-A SE International Way • Portland, OR 97222 Figure 3: Representative photomicrograph of Heat# 61869-1V (01831-1MET) taken at the core. Kalling’s. Original magnification 100X. Figure 4: Representative photomicrograph of Heat# 59762-6 (01831-2MET) taken at the core. Kalling’s. Original magnification 100X. Page 3 of 3 IMR PTL #202001831