Complete Network Power Products for Business-Critical Continuity™ 2008 2009 Catalog ~ 6 2 8 3 5 11 2 7 7 1 9 4 9 4 5 6 2 8 3 5 11 2 7 7 1 9 4 9 4 5 Grid-to-chip protection for your critical investments investments No other organization can match the scope of Emerson Network Power’s product offerings and service reach, nor provide such complete grid-to-chip protection to ensure Business-Critical Business-Cri tical Continuity ™ for your technology investment. Services Emerson Network Power supports these Centers of Expertise with the largest global services organiza organization tion in the industry, delivering: 1 2 2 – Design, installation and startup – Warranty Warra nty service – Preventive maintenance – 24x7 remote monitoring monitoring – Emergency service – Site audits 1 11 6 10 0 6 11 9 8 5 3 6 Contents A Full Spectrum of Products of Emerson Network Power DC POWER 1 OUTSIDE PLANT 16 AC POWER 23 RACKS & INTEGRATED CABINETS 41 PRECISION COOLING 43 MONITORING 48 EMBEDDED POWER 54 EMERSON NETWORK POWER. THE GLOBAL LEADER IN ENABLING BUSINESS-CRITICAL CONTINUITY.™ AC POWER CONNECTIVITY DC POWER EMBEDDED COMPUTING EMBEDDED POWER DC POWER MONITORING OUTSIDE PLANT POWER SWITCHING & CONTROLS PRECISION COOLING RACKS & INTEGRATED CABINETS SERVICES SURGE PROTECTION Supporting voice and communications networks with dependable DC power solutions. We ’ve built on trusted names-lorain®,Actura and PS-to create NetSure™ DCPower Solutions ,the next-generation global technology platform that delivers the most rigorous network-power applications,with an unparalleled breadth DC power , distribution,control and monitoring systems. DC Power. Yet another way Emerson Network Power enables Business-Critical Continuity™. 1 DC Power System DC Power System Confi guration Matrix Large system 2 Medium System Medium System Small System NetSure 801 P S486 00-3/2 900 -X5 PS48 250 -1 A/290 0 PS4 825 0-1B/2 900 Max. Power 348kW 34.8kW 14.5kW 14.5kW 14.5kW 9.6kW Voltage -48V -48V -48V -48V -48V -48V Max. Current 6000A 600A 250A 250A 250A 165A Max. Number of Rectifiers 60 12 5 5 5 3 Rectifier Type R48-5800 R48-2900 R48-2900 R48-2900 R48-2900 R48-3200,R48-2900 Controller Type M810G M500F M501D M501D M501D M501D Dimension Multi-cabinet system 600×600×2000 600×600×2000 600×400×2000 600×400×700 600×600×1600 or 584×327×132 Medium System Medium System Small System Small System Medium System PS4875/25 P S482 50-1C/29 00 PS24600/75 PS48 165 /320 0 PS48360/1800 PS48300/1800-X6 PS48120/1800-X6 Max. Power 20.88kW 17.4kW 6.96kW 4.35kW 17.4kW 7.2kW PSC48150/25 Voltage -48V -48V -48V -48V +24V -48V Max. Current 360A 300A 120A 75A 600A 150A Max. Number of Rectifiers 12 10 4 3 8 6 Rectifier Type R48-1800 R48-1800 R48-1800 HD4825-3 HD2475-2 C24/48-1200 Controller Type M501D M501D M501D PSM-A10 PSM-A11 Dimension 600×600×2000 600×600×1600 600×600×2000 450×260×700 600×600×2000 200×400×1460 Business-Critical Continuity™ NetSure 801 Stand-alone DC Power Series -48VDC up to 348kW R48-5800 Applications Large and medium switching offi ce Level-1 transmission backbone line GSM mobile switching office, mobile tandem e xchange CDMA mobile switching office, mobile tandem e xchange DC Internet data center M810G System features Space saving, 116kW(2000A@58V) capacity one cabinet Capacity expandable up to 348kW(6000A@58V) Three-phase rectifi ers (R48-5800) and SCU+(M810G) inside Wide AC input range, 260V to 530Vac, up to 600Vac endurance without damage System Effi ciency high up to 93% Power factor high up to 0.99 Output current Walk-in available Rectifiers and controller hot swappable Front access Top or bottom cabling Surge protection on AC, DC and signal side Modularized design for system and function unit TCP/IP, SNMP, web browser support Rectifier CE/UL approved Compliance with EN60590 and EN300386, ROHS Patented energy-saving mode 3 DC Power System Affi liated Cabinet AC distribution cabinet Features Local large LCD display Dual mains auto/manual switchover Front access, Top / bottom cabling DC emergency lighting available Expandable up to f ive AC cabinets Lightning proof and electric Compliance with IEC ROHS Compatible AC distribution cabinet DC distribution cabinet Features DC distribution cabinet 4 Independent monitoring unit for decentralized supply Local large LCD display Front access, Top / bottom cabling DC emergency lighting available Expandable up to 8 DC cabinets Lightning proof and electric Compliance with IEC ROHS Compatible Business-Critical Busines s-Critical Continuity™ PD48/2000HF High Ohmic Power Distribution Cabinet Features Up to 120 branches high/low ohmic output Local large LCD display Front access Lightning proof and electric Compliance with IEC ROHS Compatible PD48/2000HF PD48/1200BFH Integrated AC/DC Distribution Cabinet Features AC.DC distribution unit in one cabinet Space saving Local large LCD display Dual mains auto/manual switchover Front access Lightning proof and electric Compliance with IEC ROHS Compatible Dimensions And Weight Cabinet Rectifier Rack AC Cabinet DC Cabinet DC High Ohmic Distribution Cabinet Integrated AC/DC Distribution Cabinet Rectifier Controller Cabinet / module Rack10 Rack 1000 00-6 -6 Ca Cabi bine nett Rack Ra ck20 2000 00-6 -6 Ca Cabi bine nett PD38 PD 380/ 0/40 400A 0AFH FH-6 -6/X /X1 1 PD380/ PD3 80/630A 630AFHFH-6/X 6/X1 1 PD380/630AFA PD48 PD 48/1 /160 600D 0DFF-6/ 6/X1 X1 PD48 PD 48/2 /250 500D 0DFF-6/ 6/X1 X1 capacity 1000 10 00A A 2000 20 00A A 400A 40 0A 630A 630A 1600 16 00A A 2500 25 00A A W×D×H, mm 600×600×2000 600 600 60 0×600×2000 800 80 0×600×2000 800×600×2000 800×600×2000 800 80 0×600×2000 800 80 0×600×2000 Weigh t ( kg kg) 140(exclude recti 140(exclude rectifier) fier) 180(exclude 180(exc lude recti rectifier) fier) 240 240 Manual switchover 250 Automatic switchover 280 290 PD48/2000HF 2000A 800×600×2000 320 P D4 D48 /1 /120 0B 0BF H 1 20 200 A 800×600×2000 320 R48-5800 M810G 5800W / 244×372×88 243.5×161×88 7.8 2 PD48/1200BFH DC Power System PS48600-3/2900-X5 Integrative DC Power Series -48VDC up to 34.8kW Applications PS48600-3/2900-X5 2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations Features R48-2900 M500F Capacity up to 34.8kW (600A @ 58V) Rectifiers R48-2900(2900W)and SCU inside Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage Effi ciency high h igh up to 93% 93 % Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top or bottom cabling Rectifi Recti fier CE/UL approval appro val Compliance with RoHS Dimensions And Weight Cabinet Rectifier Controller 6 model PS48600-3/2900-X5 R48-2900 M500F W×D×H, mm 600×600×20 2000 00 85.5×287×132.5 Weight (kg) 140( 14 0(re rect ctifi ifier ex excl clud uded ed)) 3.5 Business-Critical Continuity™ PS48250-1A/2900 PS48250-1B/2900 PS48250-1C/2900 (ACTURA Flex 48330) Integrative DC Power Series -48VDC up to 14.5kW Applications 2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations PS48250-1A/2900 Features Capacity up to 14.5kW (250A @ 58V) Rectifiers R48-2900(2900W)and SCU inside Super fl exible confi guration Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage Effi ciency high up to 93% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top cabling Inner 660Ah battery shelves optional Rectifier CE/UL approval Compliance with RoHS Dimensions And Weight Cabinet Rectifier Controller model PS48250-1A/2900 PS48250-1B/2900 PS48250-1C/2900 R48-2900 M500F PS48250-1B/2900 PS48250-1C/2900 W×D×H, mm 600×600×2 00 0 600×400×2 00 0 600×400×7 00 85.5×287×132.5 Weight (kg) 1 35 (r ec ti fier ex cl ud ed) 1 25 (r ec ti fier ex cl ud ed) 6 0 ( rec ti fier ex cl ud ed) 3.5 7 DC Power System PS48165/3200 (ACTURA OPTIMA 48200) Integrative DC Power Series -48VDC up to 9.6kW Applications 2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations PS48165/3200 mode1 Features PS48165/3200 mode2 PS48165/3200 mode3 Capacity up to 9.6kW (165A @ 58V) Rectifiers R48-3200(3200W)and SCU inside Wide input voltage range (85 to 290Vac), up to 415Vac endurance without damage Effi ciency high up to 93% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Top cabling Inner dual battery shelves optional Rectifier CE/UL approval Compliance with RoHS Dimensions And Weight Cabinet S ub rac k 8 model PS48165/3200 mode 1 PS48165/3200 mode 2 P S4 81 65 /3 20 0 m od e 3 W×D×H, mm 600×600×1600 600×400×1600 5 84×327×132 Weight (kg) 75(rectifier excluded) 65(rectifier excluded) 20(rectifier excluded) Distribution U nit Location Top rear Business-Critical Continuity™ PS48360/1800 (ACTURA Flex 48420) Integrative DC Power Series -48VDC up to 20.8kW Applications 2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations R48-1800 Features Capacity up to 20.8kW (360A @ 58V) Rectifiers R48-1800(1740W)and SCU inside Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Efficiency high up to 92% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top cabling Inner 660Ah battery shelves optional Rectifier CE/UL approval Compliance with RoHS Dimensions And Weight Cabinet model PS48360/1800-X1 PS48360/1800-X2 PS48360/1800-X3 W×D×H, mm 600×600×2 00 0 600×400×2 00 0 600×600×1 80 0 Weight (kg) 1 35 (r ec tifi er e xc lu ded ) 1 25 (r ec tifi er e xc lu ded ) 1 00 (r ec tifi er e xc lu ded ) M501D PS48360/1800 DC Power System PS48300/1800-X6 Integrative DC Power Series -48VDC up to 14.7kW Applications PS48300/1800-X6 Features M501D 2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations Capacity up to 14.7kW (300A @ 58V) Rectifiers R48-1800(1740W)and SCU inside Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Effi ciency high up to 92% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top/Bottom cabling Rectifier CE/UL approval Compliance with RoHS Dimensions And Weight Cabinet R48-1800 10 model PS48300/1800-X6 W×D×H, mm 600×600×1600 Weight (kg) 130(rectifier excluded) Business-Critical Continuity™ PS48120/1800-X6 Integrative DC Power Series -48VDC up to 6.96kW Applications 2G, 3G mobile base stations small exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations Railway stations Features PS48120/1800-X6 Capacity up to 6.96kW (120A @ 58V) Rectifiers R48-1800(1740W)and SCU inside Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Effi ciency high up to 92% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top/Bottom cabling Inner 330Ah battery shelves optional Rectifier CE/UL approval Compliance with RoHS M501D Dimensions And Weight Cabinet model PS48120/1800-X6 W×D×H, mm 600×600×2 00 0 Weight (kg) 1 10 (r ec tifier e xc lu ded ) R48-1800 11 DC Power System PS4875/25 Wall-mounted Integrative DC Power Series -48VDC up to 4.35kW Applications PS4875/25 2G, 3G mobile base stations Small exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations Railway stations Features Capacity up to 4.35kW (75A @ 58V) Rectifiers HD4825-3(1450W )inside Wall-mounted for space saving Wide input voltage range (90 to 290Vac), up to 415Vac endurance without damage Effi ciency high up to 90% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top cabling Rectifier CE approval Compliance with RoHS Dimensions And Weight Cabinet 12 model PS4875/25 W×D×H, mm 450×260×7 00 Weight (kg) 4 0( re cti fier e xc lu ded ) Business-Critical Continuity™ PS4890/800 (ACTURA 48201) Subrack DC Power Series -48VDC up to 4.8kW Applications 2G, 3G mobile base stations small access networks Microwave/satellite communications stations Features 19” Subrack system Capacity up to 2.4kW one subrack, 4.8kW dual subracks Rectifiers R48-800(800W)and SCU inside Wide input voltage range (85 to 300Vac) Effi ciency high up to 91% Power factor high up to 0.99 Output current Walk-in available Patented energy-saving mode available Intelligent monitoring and remote control BLVD, LLVD optional Rectifiers and controller hot swappable Rectifier CE/UL approval Compliance with RoHS Dimensions And Weight model PS4890/800 single subrack PS4890/800 dual subracks W×D×H, mm 485×345×90 485×345×180 Weight (kg) 8.8(rectifier excluded) 17.9(rectifier excluded) 13 DC Power System PS24600/75 Integrative DC Power Series +24VDC up to 17.4kW Applications PS24600/75 2G, 3G mobile base stations Medium exchanges, rural telecom networks and access networks Transmission relay stations Microwave/satellite communications stations Key Features Capacity up to 17.4kW (600A @29V) Rectifiers HD2475-2(2175W )inside Wide input voltage range (120 to 290Vac), up to 415Vac endurance without damage Effi ciency high up to 88% Power factor high up to 0.99 Intelligent monitoring and remote control Surge protection on AC, DC and signal side Rectifiers and controller hot swappable Front access Top or bottom cabling Rectifier CE approval Compliance with RoHS Dimensions And Weight Cabinet Rectifier Controller 14 model PS48600-3/2900-X5 HD2475-2 PSM-A11 W×D×H, mm 600×600×2 00 0 105 ×400×245 Weight (kg) 1 58 (r ec ti fier ex clu de d) 8 Business-Critical Continuity™ PSC48150/25 Integrative DC Power Series +24Vdc/-48Vdc, 7.2kW Applications 2G, 3G mobile base stations Medium exchanges Transmission relay stations Microwave/satellite communications stations Features +24V/-48V DC/DC system Capacity up to 7.2kW Wide DC input voltage range: 21V~29V DC/DC module(1200W)inside DC/DC converter Hot-swappable Extremely low radiation, meeting Relay output for alarm port Complete lightning proof in input and output rated at 5KA(8/20us) Complete fault protection functions Optional remote monitor and control Front access Compliance with RoHS PSC48150/25 Dimensions And Weight Cabinet DC/DC converter model PSC48150/25 C24/48-1200 W×D×H, mm 200×400×146 0 85.5×287×132.5 Weight (kg) 45 (rectifier excluded) 2.5 1 EMERSON NETWORK POWER. THE GLOBAL LEADER IN ENABLING BUSINESS-CRITICAL CONTINUITY.™ AC POWER CONNECTIVITY DC POWER EMBEDDED COMPUTING EMBEDDED POWER OUTSIDE PLANT MONITORING OUTSIDE PLANT POWER SWITCHING & CONTROLS PRECISION COOLING RACKS & INTEGRATED CABINETS SERVICES SURGE PROTECTION Protecting and moving voice ,video and data from the central office closer to the subscriber. We deliver a f ull line of enclosures,cabinets and shelters that meet the networked world’s demands for high speed without interruption, from MESA® and DEC integrated enclosure solutions to Emerson Network Power ES, EC, EPC outdoor power solutions to cross-connects to ProFORM® distribution terminals to NetSpanTM Integrated FTTx Solutions. OUTSIDE PLANT. Yet another way Emerson Network power enables Business-Critical Continuity™. 16 Business-Critical Continuity™ EPC48180/1800-FA -48VDC Outdoor Power Cabinet Applications Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers Features Capacity up to 10.44kW (180A @ 58V) Totally front access in favor of space-saving Forced vent cooling system Patent design of Isolated air channel for safe operation IP55 for equipment chamber Forced vent cooling for battery chambers Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Rectifiers R48-1800(1740W) and SCU inside Efficiency high up to 92% Power factor high up to 0.99 Output current Walk-in available Perfect fan speed control for energy-saving Patent energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Class B+C lightning protection optional Rectifiers and controller hot swappable Inner dual 330Ah battery Chambers Rectifier CE/UL approval Compliance with EN60950 and IEC60950, RoHS H-mast platform installation available EPC48180/1800-FA Dimensions And Weight Cabinet model EPC48180/1800-FA W×D×H, mm 700×700×1700 Weight (kg) 150(rectifiers and batteries excluded) 17 Outside Plant EPC48120/1800-F -48VDC Outdoor Power Cabinet Applications EPC48120/1800-F Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers Features Capacity up to 6.96kW (120A @ 58V) Totally front access in favor of space-saving Forced vent cooling system IP45 for equipment chamber Patent design of Isolated air channel for safe operation Forced vent cooling for battery chambers Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Rectifiers R48-1800(1740W)and SCU inside Effi ciency high up to 92% Power factor high up to 0.99 Output current Walk-in available Perfect fan speed control for energy-saving Patent energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Class B+C lightning protection optional Rectifiers and controller hot swappable Inner dual 330Ah battery Chambers Rectifier CE/UL approval Compliance with EN60950 and IEC60950, RoHS H-mast platform installation available Dimensions And Weight Cabinet 18 model EPC48120/1800-F W×D×H, mm 600×630×1500 Weight (kg) 140(rectifiers and batteries excluded) Business-Critical Continuity™ EPC48120/1800-HA(B) -48VDC Outdoor Power Cabinet Applications Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers Features Capacity up to 6.96kW (120A @ 58V) Totally front access in favor of space-saving Heat-exchange cooling system IP55 for equipment chamber Wide operation temperature, -40~+45℃ optional Patent design of Isolated air channel for safe operation Forced vent cooling for battery chambers Wide input voltage range (85 to 300Vac), up to 415Vac endurance without damage Rectifiers R48-1800(1740W)and SCU inside Efficiency high up to 92% Power factor high up to 0.99 Output current Walk-in available Perfect fan speed control for energy-saving Patent energy-saving mode available Intelligent monitoring and remote control Surge protection on AC, DC and signal side Class B+C lightning protection optional Rectifiers and controller hot swappable Inner dual 330Ah battery Chambers Rectifier CE/UL approval CE mark Compliance with EN60950 and IEC60950, RoHS H-mast platform installation available EPC48120/1800-HB Dimensions And Weight Cabinet model EPC48120/1800-HA EPC48120/1800-HB EPC48120/1800-HA Op. temp. -10 +45℃ -40 +45℃ ~ W ×D×H, mm Weight (kg) 600×600×1700 150(rectifiers and batteries excluded) ~ 19 Outside Plant EC200T/01 Outdoor Battery Cabinet Applications EC200T/01 Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers Features Cater up to 3 strings of 165Ah batteries Thermoelectricity cooler (TEC) inside Inner temperature 5~15℃ below outside ambient IP55 Dry-contact alarm for fans and door sensor Compliance with RoHS Dimensions And Weight Cabinet 20 model EC150F/01 Op. temp. -10 +55℃ ~ W×D×H, mm 650×720×1 40 0 Weight (kg) 1 00 (ba tt eri es e xc lu ded ) Business-Critical Continuity™ EC150F/01 Outdoor Battery Cabinet Applications Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers EC150F/01 Features Cater up to 2 strings of 165Ah batteries Forced vent cooling IP34 Dry-contact alarm for fans and door sensor Compliance with RoHS Dimensions And Weight Cabinet model EC150F/01 Op. temp. -10~+45℃ W ×D×H, mm 700×700×1 00 0 Weight (kg) 1 00 (b at ter ies ex cl ude d) 21 Outside Plant EC100F/01 Outdoor Battery Cabinet Applications Outdoor stations of GSM, UMTS, CDMA Fiber optic transmission systems Digital loop carriers EC100F/01 Features Cater up to 2 strings of 165Ah batteries Forced vent cooling IP34 Dry-contact alarm for fans and door sensor Compliance with RoHS Dimensions And Weight Cabinet 22 model EC100F/01 Op. temp. -10 +45℃ ~ W×D×H, mm 600×600×1 00 0 Weight (kg) 1 00 (ba tt eri es e xc lu ded ) EMERSON NETWORK POWER. THE GLOBAL LEADER IN ENABLING BUSINESS-CRITICAL CONTINUITY.™ AC POWER CONNECTIVITY DC POWER EMBEDDED COMPUTING EMBEDDED POWER AC POWER MONITORING OUTSIDE PLANT POWER SWITCHING & CONTROLS PRECISION COOLING RACKS & INTEGRATED CABINETS SERVICES SURGE PROTECTION Sustaining critical operations that simply can ’t go down. We deliver a full range of uninterruptible Liebert® AC power systems and complete associated power distribution and enclosures , from individual products to integrated systems that keep network closets up and running. AC Power. Yet another way Emerson Network Power enables Business-Critical Continuity™. 23 AC Power AC POWER Confi guration Matrix 24 Small System Medium System Small System SERIES: US11R iTrust 31 iTrust 2G RATING: 1/2/3KVA 10/15/20KVA 3/6/9/12/15/18KVA MOUNTING: Tower/Rack Tower Tower/Rack I/O: 1-ph./1-ph. 3-ph./1-ph. 1-ph./1-ph. VOLTAGE: 220/230/240 (L-N) 380/220 220 (L-N) FREQUENCY: 50Hz 50Hz 50Hz Large system Medium System SERIES: NX Hipulse-U RATING: 10/15/20/30/40/60/80/100/120/140/160/200KVA MOUNTING: Tower Tower Tower I/O: 3-ph./3-Ph. 3-ph./3-ph. 1-ph./1-ph. VOLTAGE: 380/400/415 (L-L) 380/400/415 (L-L) 220(L-N) FREQUENCY: 50/60Hz 50/60Hz 50Hz 160/200/300/400KVA Outdoor UPS 2KVA/3KVA Business-Critical Continuity™ US11-R Series 1/2/3KVA Applications Servers/Storage/Workstation Telecommunication, VoIP Small Office Network Data Warehouses Medical Diagnostics Process Automation Equipmentsv Special Features Rack/Tower design, adaptable for table and 19' IT rack application Double conversion, true on-line style Fully digital control Input surge suppressor equipped CE marked IGBT based rectifier and excellent input performance Super wide input window Mutiple AC output connections 2U height High EMC performance, classB achieved Intelligent battery management Dimensions And Weight Model Name US11R-0010 US11R-0010L US11R-0020 US11R-0020L US11R-0030 US11R-0030L UF-B0007-06 UF-B0009-06 Size(WDH in MM) 440×400×87 440×400×87 440×400×87 440×400×87 440×400×87 440×400×87 440×400×87 440×400×87 Weight(Kg) 17.5 7.8 29.1 9.6 30.5 10.5 20.5 21.5 Note: US11R-0020 will be shipped with a VF-B0007-06 US11R-0023 will be shipped with a VF-B0009-06 25 AC Power US11-R Series Datasheet US11R-0010 US11R-0010L 1KVA Model Nominal Power Rating at 0.7 PF Input Parameters Rectifier Type IGBT-based PFC(Power Factor Correction) Input Voltage 220Vac, Permissible Input Voltage Range Permissible Input Frequency Range Input Power Factor at nominal voltage Battery Battery Type Nominal Battery Bus Recharging Time to 90% Recovery Output Parameters Inverter Type Output Power Output Connection Output Voltage Output Frequency Output Voltage THD Capability to handle High Crest Factor Load Capability to handle Step L oad 120-288Vac 50Hz ±2%,5%,7%,10% User selectable ≥0.99 Overload Capability System Parameters & Standards AC-AC Efficiency Switch Time When Input Fails Noise Display Dimension (W×D×H)mm U-Height Weight (Standard/L model) Safety EMI /EMC Inmunity Surge Protection Protection Communication & Management Interface Port Web/SNMP Card Environmental Parameters Operating Temperature Range Relative Humidity Maximum Altitude above MSL 26 US11R-0020 US11R-0020L 2KVA US11R-0030 US11R-0030L 3KVA 1-ph, 3-w Maintenace Free, V RLA (Valve Regu lated Lead Acid) 36Vdc 72Vdc <4 hours <4 hours 72Vdc <4 hours IGBT-based Inverter 0.7kW 1.4kW GB/IEC GB/IEC 220Vac, 1-ph, 3-w 50Hz ±0.2% <3% at linear load; < 5% at non-linear load 3:1 (compliant with IEC 62040-3) 10 0% 105% FL Infi nite 105-125% FL for 5 mins 125-150% FL for 1min >150% FL for 10s >89% 2.1kW GB/IEC/Terminal >90% >90% 0s <43dB LED 440×400×87 2u 17.5/7.8kg EN62040-1-1, CE Marked EN50091-2 Class B EN50082-1 IEC 60664-1 Level IV IP21 <45dB 2u 29.1/9.6 Serial / Dry Contact / SNMP Card Optional 0 ℃ to 40℃ (UPS) & 25℃ ±5 (Battery) 0% to 95% (non-condensing) 1500m (as per IEC 62040-3) 2u 30.5/10kg Business-Critical Continuity™ UH31 Series 10/15/20KVA Applications Small data centers of banks/stock exchanges, server groups, small/middle computer rooms, offices, PC groups, important facilities, etc Features Three phases input, one phase output ( 220/230Vac) True on-line style IGBT based rectifier/inverter DSP control Super wide input window (-45% +15%) On-line operation when input phases lose D-class surge suppressor equipped Intelligent battery management Chinese/English LCD interface available Class A EMC standard acquired Input phase loss tolerance ~ Dimensions And Weight Model Name UH31-0100L UH31-0150L UH31-0200L Size(WDH in MM) 280×875×770 280×875×770 280×875×770 Weight(Kg) 97 97 116 27 AC Power UH31 Series Datasheet Model Nominal Power Rating at 0.7 PF Input Parameters Rectifier Type Input Voltage Permissible Input Voltage Range Permissible Input Frequency Range Input Power Factor at nominal voltage Battery Battery Type Nominal Battery Bus Output Parameters Inverter Type Output Power Bypass Voltage Ran ge Output Voltage Output Voltage Regulation Output Frequency Output Voltage THD Capability to handle High Crest Factor Load Capability to handle Step Load Overload Capability System Parameters &Standards AC-AC Efficiency S wit ch Ti me W hen I np ut F ai ls Noise Display Dimension (W×D×H) Weight (Standard/L model) Safety Im mu ni ty EMC Surge Protection Parameters &Standards Operating Temperature Range Relative Humidity Maximum Altitude above MSL 28 UH31-0100L 10KVA UH31L-0150 15KVA UH31-0200L 20KVA IGBT-based PFC (PF Corrected) 380Vac, 3-ph, 4-w 120Vac-276Vac 45-55Hz ≥0.95 VRLA (Value Regulated Lead Acid) 480Vdc 480Vdc 480Vdc IGBT-based Inverter 7kW 10.5kW 120 Vac -25 3Vac 220Vac, 1-ph, 3-w ±0.5% 50Hz < 3% at linear load; < 5% at non-linear load 3:1 (compliant with IEC 62040-3) 14kW 100% 105-125% FL for 10 mins 125-150% FL for 1min >150% FL for 200ms >91% >92% 0s <55dB <60dB LED+LCD 280×875×770mm 97kg 116kg EN60950 EN 61 00 0-4 -2 ,3 ,4 ,6 ,8 ,1 1 L ev el I II , EN 61 00 0-4 -5 L ev el I V EN55022 Class A IEC 60664-1 Level IV 0 ℃ to 40℃ (UPS) & 25℃ ±5℃ (Battery) 0% to 95% (n on-condensing) 1500m (as per IEC 62040-3) Business-Critical Continuity™ iTrust 2G Series UPS Applications Industrial equipments Small data centers Computing centers Telecommunication network hubs Features Modular Design- Plug & Play N+X Redundancy - Higher reliability Easy and cheap expansion- Modules only Online during maintenance- By simply replacing modules Space saving - Compact Design Large Capacity Battery Affordable -Extendable 10A/20A charger available Energy Saving - High Efficiency and excellent input PF Higher adaptability to harsh input - Extremely Wide Input window Longer battery life available - Intelligent Battery Management Quiet - Low noise Less worry - Self diagnosis and Fault Prediction Dimensions And Weight Model Name Power Module UF-P0030 Battery Module UF-B0007-8 10A Charger Module UFP-BCH110/10 20A Charger Module UFP-BCH110/20 6-Bay Rack UP11-0180/6 12-Bay Rack UP11-0180/12 Size(WDH in MM) 436 × 412 × 85 436 × 400 × 36 436 × 412 × 85 436 × 412 × 85 500 × 552 × 994 500 × 552 × 1492 Weight(Kg) 10.4 26 7.6 10.4 70 105 29 AC Power iTrust 2G Series Datasheet Models Model Name Input Parameters Rectifier Type Input Voltage Permissible Input Voltage Range Permissible Input Frequency Range Input Power Factor at nominal voltage Ace Battery Battery Type Nominal Battery Bus Output Parameters Inverter Type Output Rating Output Power Factor Output Voltage Output Voltage Regulation Output Frequency Capability to handle High Crest Factor Load Capability to handle Step Load Compliance to EMC Class-A Overload Capability System Performance AC-AC Efficiency Transfer Time When Input Fail Environmental Parameters Operating Temperature Range Relative Humidity Maximum Altitude above MSL Physical Parameters &Standards Colour Degree of Protection 30 3KVA 6KVA 2.4kW 4.8kW UP11-0180/12(12-Bay) 9KVA 12KVA 7.2kW 9.6kW UP11-0180/6(6-Bay) IGBT-based PFC 220Vac/1ph/3w 120-288Vac 45-55Hz ≥0.99 without any Filter VRLA 96Vdc IGBT-based 3/6/9/12/15/18 KVA 0.8 220Vac/1ph/3w 1% 50Hz 3:1 10 0% Applicable for both Radiated & Conducted 105% FL for continuous running 125% FL for 10 minutes 150% FL for 10 S > 90% 0s 0 ℃to 40℃ (UPS) 0% to 95% (non-condensing) 1500m (as per IEC 62040 3) Black IP21 15KVA 12kW 18KVA 14.4kW Business-Critical Continuity™ NX Series UPS Applications Server Rooms and Mid-sized Data Centers Telecommunication (Fixed, WiLL & Mobile) Billing Computers Networks (LAN, MAN & WAN), InfoCom and WiFi Hot Spots Industrial Process & Motion Automations for Mid-sized Plants Medical Diagnostic / Imaging Equipment Features Full digital control based on latest DSP Advanced Vector Control to Achieve Excellent Output Performance 'Green UPS' Design with High input power factor : 0.99 Low input current harmonic of less than : 3% Wide input window : 208-477V (L-L voltage) Parallel up to 6 units, No MSS needed High Efficiency: up to 94% Compact Footorint and Front Access Unique Dual Bus design Flexible Power Walk-in Built-in Redundancies to Achieve High Reliability(fans/auxiliary power supply card/..) Intelligent battery management Self diagnosis Dimensions And Weight Model Name NXe-10KVA NXe-15KVA NXe-20KVA NXe-30KVA NXa-40KVA NXa-60KVA NXa-80KVA NXa-100KVA NXa-120KVA NXa-140KVA NXa-160KVA NXa-200KVA Size(WDH in MM) 600×700×1400 600×700×1400 600×700×1400 600×700×1400 600×825×1600 600×825×1600 600×825×1600 700×825×1800 700×825×1800 1000×825×1800 1000×825×1800 1000×825×1800 Weight(Kg) 180 204 204 260 340 400 445 720 720 824 973 973 31 AC Power NX Series Datasheet Nxe10 Nxe15 Nxe 20 Nxa30 Nxa40 Nxa60 Nxa80 Nxa100 Nxa120 Nxa140 Nxa160 Nxa200 Models NominalPowerRatingat0.8PF 10KVA 15KVA 20KVA 30KVA 40KVA 60KVA 80KVA 100KVA 120KVA 140KVA 160KVA 200KVA Input Parameters Rectifier Type IGBT-based Vector Controlled PFC (PF Corrected) Input Voltage 380/400/415Vac (Accepted from 305-477Vac without Batt. Use) In pu t F re qu en cy 4 0- 70 Hz Input Current THD <3% (without any Filter) Input Power Factor ≥0.99 (without any Filter) Flexi Power Walk-In 5 to 30S (Selectable) Battery Battery Type VRLA (Value Regulated Lead Acid) / Wet-Flooded / NiCd End-Cell Voltage Selectable from 1.60-1.90Vdc/Cell (VRLA) DC ripple Current in fl oat <5%(C10 AH Capacity) RMS Value mode DC ripple Voltage in <1% (RMS Value) fl oat & Const V Ch.mode Temperature Standard (for in-build batteries for 10/15/20/30/40 KVA) Compensated Battery Optional (fo r all other battery confi guration s) Charging In-Built VRLA Battery Optionally applicable for 10/15/20/30/40 KVA Availability Output Parameters Inverter Type IGBT-based Vector, Repetitive & PI Controlled Output Power 8kW 12kW 16kW 24kW 32kW 48kW 64kW 80kW 96kW 112kW 128kW 160kW Output Voltage 380/400/415Vac * (Nominal: 400V) 3-ph, 4-w (Ph+N) Output Voltage ±0.5% Regulation O ut pu t F re qu en cy 5 0/ 60±0.05Hz Regulation Output Voltage THD 1% (max) Max. Crest Factor Load 3:1 (compliant with IEC 62040-3) Capability to handle 100% Step Load Max. Leading PF Load Up to 0.9 Voltage Displacement 120o±1oel (with 100% unbalanced load) Overload Capability 110 for 60 minutes, 125 for 10 minutes, 150 for 1 minutes Standards EMC Class Class A (Applicable for both Radiated & Conducted) Enclosure IP IP 20 even with front door in opened condition, IP21 Optional Standards & IEC 62040-3, IEC 62040-2, IEC 62040-1-1, IEC 60146-1-1, IEC 61000-4-2,4,5,6,8,11, EN 50091-1-1, Conformities EN 50091-2, EN 50091-3, EN60950, EN 60529, ANSI C62.41 (IEEE 587) Environmental Parameters Operating Temperature 0 to 40℃ (UPS) & 25 ±5℃ (Battery) Range Relative Humidity 0 to 95% (non-condensing) Maximum Altitude 1000m (as per IEC 62040-3) above MSL 32 Business-Critical Continuity™ Hipulse-U Series 160/200/300/400KVA Applications Medinm & large Data Center Telecommunication Industrial Automation Transport Automation Banking, Insurance and Financial Sernices Software Development Houses/Software Technology Parks(STP) Building Automation Medical Diagnostics Satellite Features Fully Digital, Twin DSP controlled. Rated at 0.9 output power factor to deliner more real power Handle Leading Power factor Loads withour KW de-rating under specified conditions On-Line Double Conversion IGBT-based PWM Inverter Wide input voltage tolerance(+15/15%) Wide input frequency tolerance(45Hz-65Hz) High overload capability of static bypass(14 times for 10 milliseconds and 10 times for 100 nukkusecibds) Built-in maintenance bypass(Single and 1+N Models) Wrap-around maintenance bypass(optional) Front acces for spares replacement and preventive maintenance Easy Dual bus Configuration architecture Adjustable frequency synchronisation window up to 9% in the static bypass Provision of automatic battery circuit breaker instead of using conventional isolator in the DC path Field protocols ModBus/Jbus Eady Scalability (Parallel 1+N configuration up to 6 modules paralleling)without centralised Main Static Switch (MSS) Bypass Switch Compact footorint Dimensions And Weight Model Name Hipusle U-160KVA, 6 Pulse Hipusle U-160KVA, 12 Pulse Hipusle U-200KVA, 6 Pulse Hipusle U-200KVA, 12 Pulse Hipusle U-300KVA, 6 Pulse Hipusle U-300KVA, 12 Pulse Hipusle U-400KVA, 6 Pulse Hipusle U-400KVA, 12 Pulse Size(WDH in MM) 1250×840×1910 1640×840×1910 1250×840×1910 1640×840×1910 1640×840×1910 2280×840×1910 2280×840×1910 2280×840×1910 Weight(Kg) 1200 1725 1350 2000 1600 2200 2100 2750 33 AC Power Hipulse-U Series Datasheet Hipulse UPS System Nominal Rating(KVA)(0.9pf)/kW 160/144 200/180 300/270 400/360 Rectifier Type 6P 12P 6P 12P 6P 12P 6P 12P Input Voltage 380/400/415V(+/-15%)-3Ph-4w(rectifier:290-498V) Frequency 50 or 60Hz +/-5% ITHD 4 to 9% with optional harmonic filter Power Factor 0.90-0.95 with optional harmonic filter Output Voltage 380/400/415V-3Ph-4w Voltage stability -Steady state +/-0.5% -100% Load Step +/3% Frequency 50 or 60Hz Frequency Stability -Synchronised with the bypass supply +/0.5 Hz, +/-1 Hz, +/-2Hz, +/-3Hz(settable) -Auto-Synchronised +/0.1% Overload copacity from inverter at vominal voltage -3 Ph 110% for 60 minutes, 125% for 10 minutes, 150% for 1 minute -1 Ph 200% for 30 seconds short circuit current from inverter -3 Ph 1.5 in for 5 seconds (in acordance with EN 50091-1-1) -1 Ph 2.9 in for 5 seconds 2.2 in for 5 seconds Voltage Distortion with Linear Load <3% Voltage Distortion with 100% <5% Non-Linear Load Max.Deliverable Power 100% with Non-Linear Load(CF-3:1) Max Unbalanced Load 100% Voltage Displacement With 120o+/-1oel 100% Unbalanced Load Output Voltage Dissymmetry 2% with 100% Unbalanced Load Standards and Approvals Safety / EMC / Design IEC60950-1,IEC62040-1-1,UL1778,IEC62040-2 CLASS A,EN50091-CLASS A,IEC62040-3 European Directives CE 73/23/EEC and 89/336/EEC 34 Business-Critical Continuity™ Outdoor Series Application Outdoor BTS Special Features Natural cooling, high system reliability achieved Dual conversion, online style Fully digital control Auto start up when mains recovered Super wide input window (150-310V L-N) IP55 protection level Wide operation Temperature: -40-550C High level surge suppressor can be equipped inside; (Optional) Boosted/oat charging auto transfer 3 mounting options available (wall/mask/oor) Zero output interrupt when input fails Optional charger for quick battery recovery in long backup system Heater optional for cold area Optional Battery cabinet available with maximum 4 hours backup time at full load Power module separate with battery enclosure, high system exibilit y achieved Dimensions And Weight Model Name Outdoor 2KVA UPS Outdoor 3KVA UPS Battery Cabinet (South Type) Battery Cabinet (North Type) *: Including Mounting Kit,36Kg Net **: Including Mounting Kit,42Kg Net UH11-0020LC UH11-0030LC U6-100C3S U6-100C3N Size(WDH in MM) 485×263×615 485×263×615 850×550×1170 850×550×1170 Weight(Kg) 53* 59** 70 72 35 AC Power Outdoor Series Datasheet Capacity Model Name Input Rated Voltage Voltage Range Frequency Power Factor Output Powe Factor Normal Voltage Frequency Frequency Tracking Rate Inverter Overload Capability Peak Factor Bypass Voltage Efficiency (NormalMode) Sheft Time Utility Failure Shift between invertermode and bypass mode (Synchronized ) Insulation In su lation Resistanc e Dielectric Strength Environment O per ati on tem per at ur e Storage temperatu re r el ati ve h um idi ty altitude Protection Level Noise 36 2KVA/3KVA UH11-0020LC, UH11-0030LC 220Vac 150-310Vac 45~65Hz > 0.98 0.7 temp<5℃ 0.6 temp>10℃ 220Vac 3% 50Hz ≤1 Hz/s 105%-125%, 5mins, >125%, 20s, 3:1 150~310Vac >89% 0ms < 10ms >2MΩ(500Vdc) (Output to earth Input to earth)2820Vdc,leakage current <3.5mA for 1min without arc or breakdown -4 0℃ -55℃ -40 ℃ -70℃ 1 0% -1 00 % ( no c on den si ng ) Under 4000m, over 4000m, de-rated, IP55 <40dB Business-Critical Continuity™ Monitoring Solutions Our Monitoring Solution Includes 5 Parts 1.Point-to-point and internet-based network remote monitoring, unlimited with the number of nodes 2.SNMP Card: An internet node, providing UPS with Ethernet communication capability 3.UPS Network Adapter: Monitoring UPS products of other brands 4.UPS Adapter for Equipment Room Signals Applied together with our SNMP Card, realizing centralized monitoring and processing of multi environment measures such as temperature, humidity, infrared, door alarm, water immersion ( 8 analogues and 8 dry contacts) 5.Wireless MODEM: Able to send wireless messages, reporting UPS operation status and alarms to the customers and realizing No-Man-On-Duty Features Java programming language. Web-based general-purpose monitoring software Compatible with multi operation systems, eg., Windows, Linux, Solaris, AIX, HP-UX, etc. Can log on via any computer on network UPS by-layer management mode Complete history records for inquiry, statistics and preview before printing Multi alarming: Sound, paging, email and messages, etc. Multi language versions, on-line upload and upgrade WEB-configured interfaces, very easy to operate Large storage of history records Least system resource occupied Strict safety management mechanism On-line smooth access system for new equipment Multi system environment measures accessible 37 AC Power SiteMonitor 1. Easy installation 2. Clear display of UPS operation status Can name based on requirements and display by layer Click on UPS icons to check all operation indices and historical records online, with power status completely in hand 3. Easy setting and adjustment Under authorization, a network administrator can remotely control the center, eg. operate turnoff, battery selfdiagonosis, erase after sound alarm, etc. 38 Model selection and confi guration Business-Critical Continuity™ SNMP Card-A Bridge Connecting UPS and Network The SNMP card is based on TCP/IP communication protocol and can also support SNMP, HTTP(web server), Telnet communication protocols to meet the needs of all sorts of networks Features Supports web browse and NMS management systems Software can be updated on line 10/100M network self-adapting Hot plug-in/plug-out supported All the settings can be done through software 39 AC Power Intelligent Battery Management Auto-adaptable on EOD(End Of Discharge) Adjustment Different discharging solution for short backup-time system (<1h) and long backup-time system(>1h) The data of different models of batteries are stored in DSP and the UPS will detect the discharging current and automatically adjust the EOD for best performance of the battery. In this way, overdischarge of battery is avoided Self-diagnosis Battery self-diagnosis can be set to operate periodically via front panel Auto-switch between Boost and Float Recharging Shorten recharging period and prolong the battery life by 50% Temperature Compensation 40 Auto-adjustment for fl oat charging voltage according to ambient temperature EMERSON NETWORK POWER. THE GLOBAL LEADER IN ENABLING BUSINESS-CRITICAL CONTINUITY.™ AC POWER CONNECTIVITY DC POWER EMBEDDED COMPUTING EMBEDDED POWER RACKS & INTEGRATED CABINETS MONITORING OUTSIDE PLANT POWER SWITCHING & CONTROLS PRECISION COOLING RACKS & INTEGRATED CABINETS SERVICES SURGE PROTECTION Optimizing technology and performance needs for the global IT and telecom markets. We deliver standard and customized integrated cabinet solutions that meet unique and specifi c needs, from knürr and Liebert® rack solutions for customer rooms of all sizes to knürr ,MESA® and Netspan™、Matrix™ enclosures and shelters for wireline and wireless applications. RACKS & INTEGRATED CABINETS .Yet another way Emerson Network power enables BusinessCritical Continuity™. 41 Racks & Integrated Cabinets Server Enclosure Systems Rack system and IT total solution Emerson Network Power Co.,Ltd. Launched the high reliability and high availability rack system and IT room total solution that suit the features of blade server based on its deep understanding in the user ’s requirements for IT application and the existing issues. Applications Network access rooms Computer rooms Data center Features and Benefits World-leading heat dissipation design: The 83% perforating rate that is the highest in the world meets the heat dissipation requirement of high thermal-density of blade server Special modular structure: Modular structure and modular installation: Convenient storage and transportation, fast and convenient disassembly and assembly Reliable and stable power supply and distribution design: double conversion online UPS, the total power distribution solution meets the different customer requirements Convenient cable management: Comprehensive cable management accessories meet the different cable management requirements Advanced rack monitoring and safety system: Remote monitoring to the rack environment, including temperature, humidity, door alarm and smoke, etc Miracel Series: Product Type NR-M060820 SR-M061020 SR-M061220 SR-M081020 SR-M081220 Accessories 42 Capacity 42U 42U 42U 42U 42U Width(mm) Distance(mm) High(mm) 600 800 2000 600 1000 2000 600 1200 2000 800 1000 2000 800 1200 2000 Fan, plinth, cable management unit, power distribution unit, etc. EMERSON NETWORK POWER. THE GLOBAL LEADER IN ENABLING BUSINESS-CRITICAL CONTINUITY.™ AC POWER CONNECTIVITY DC POWER EMBEDDED COMPUTING EMBEDDED POWER PRECISION COOLING MONITORING OUTSIDE PLANT POWER SWITCHING & CONTROLS PRECISION COOLING RACKS & INTEGRATED CABINETS SERVICES SURGE PROTECTION Maintaining precise temperature for reliable equipment performance. We deliver “chip-to-room cooling ”-the most comprehensive range of liebert® precision-cooling solutions,which protect mission-critical applications from even the slightest increase in temperature. PRECISION COOLING. Yet another way Emerson Network power enables Business-Critical Continuity™. 43 Precision Air Conditioning Liebert DataMate3000(S) Precision cooling for Small Equipment Rooms DataMate3000 series air conditioning is developed by Emerson Network Power Co., Ltd. for small equipment rooms. The system provides 5.5kW , 7.5kW and 12.5kW cooling capacities and many configuration options. Applications Mobile base stations and control centers Communications base stations Outdoor equipment rooms Microwave/Satellite earth stations Medium ,Small computer rooms Features and Benefits High sensible cooling capacity and energy efficient. Saves 20-30% energy as compared to "comfort" air conditioner Provides consta nt temperature and humi dity, high air flow rate and low energy consumption to meet specifi c reqirements of computer rooms Copeland scroll compressor provides high reliability, efficiency and maximum li fe Large LCD display, password protection and self diagnosis Wide input voltage range, allowing voltage fl uctuation 20% Phase loss protection ,phase order detection, automatic regulation to phase disorder Automatic startup when utility is recovered Front access ,easy for maintenance and fl exible installation Standard port for monitoring equipment Flexible and automatic switchover and alternative operation between master and slave Dimensions And Weight model Indoor model DataMate3000(s) Outdoor model 44 DME05W DME07W DME07M DME12M DMC07W DMC12W W×D×H, mm 510×386×1740 510×386×1740 500×550×1900 500×550×1900 702×408×626 702×408×1238 Weight (kg) 80 85 150 160 34 58 Capacity 5.5 kW 7.5 kW 7.5 kW 12.5 kW 7.5kW 12.5 kW Business-Critical Continuity™ Liebert PEX Precision cooling for medium/large equipment room The Liebert PEX is the next generation precision air conditioning system from Emerson Network Power. The PEX is the latest in a long line of advanced products from the Liebert family designed to support business-critical applications. Applications Data Centres Telecom/CATV Computer Rooms Labs and Test Rooms Network Centres Production Facilities Hospitals and medical diagnostic rooms Features and Benefits Front access for convenient maintenance. There is no need to keep back or sides clear The Liebert iCOM™ control system offers the highest capabilities of unit control, communication and monitoring ICOM network provides a choice of Teamwork, Lead/Lag and Cascade functions A-Frame Evaporator Coils has larger surface to provide even air flow distribution. Its heat exchange is highly efficient Unique fan driving system ensures stable system operation and more efficient airflow Infrared Humidifier, Full capacity achieved in 5-6 seconds using almost any water quality; Approved for direct connection to potable water supplies; Autoflush™ cycle helps remove mineral deposits All compressorised models are designed to operate on either HCFC R22 or HFC R407C refrigerants High kW to footprint ratio 45 Precision Air Conditioning Dimensions And Weight model P1020 P1025 P1030 P1035 P2045 P2055 P2040 P2050 P2060 P2070 P3080 P3090 P3100 46 Total Capacity(kW) (24℃/50%RH) 20.0 23.1 30.1 33.1 45.0 53.2 41.0 46.4 60.6 66.9 81.4 89.3 100.0 Weight (kg) 365 375 385 388 530 570 622 661 680 687 825 825 835 L×W×H, mm 853×874×1970 1704×874×1970 2553×874×1970 Business-Critical Continuity™ Liebert XD Flexible, Energy-Saving Cooling Solutions For High Heat Density Applications Applications IDC Blade servers High density servers and communications switches Rooms existing high heat density Features and Benefits Can cool more than 30 kW per rack Floor-mount, rack-mount and ceiling-mount modules, plus a choice of cooling capacities, cover any application requirements Pumped refrigerant solutions are ideal for use around electronic equipment. No water into the room Scalable – add or move fan coils as your needs Energy effi cient. Total energy savings potential of up to 40% can be achieved with the Liebert XD solution Minimal fl oor space requirements all ow more room for I T equipment Dimensions And Weight model Main Unit Cooling Module XDP160 XDC160 XDO20 XDV10 XDH20 XDH32 Total Capacity(kW) (24℃/50%RH) 140 130 17.7 8.3 19 27 Weight (kg) W×D×H, mm 372 817 68 35 112 112 965×864×1981 1879×879×1981 1829×610×572 597×(749-1003)×355 300×1066×1982 300×1066×1982 47 EMERSON NETWORK POWER. THE GLOBAL LEADER IN ENABLING BUSINESS-CRITICAL CONTINUITY.™ AC POWER CONNECTIVITY DC POWER EMBEDDED COMPUTING EMBEDDED POWER MONITORING MONITORING OUTSIDE PLANT POWER SWITCHING & CONTROLS PRECISION COOLING RACKS & INTEGRATED CABINETS SERVICES Managing critical equipment activity at multiple sites and site monitoring around the clock. We make it easy in today ’s ROL-driven business environment,with 24/7 remote and selfmonitoring systems and services that provide continuous oversight of data centers ,computer rooms and network closets ,as well as wireless , wireline and enterprise telecom applications. MONITORING. Yet another way Emerson Network power enables Business-Critical Continuity™. 48 SURGE PROTECTION Business-Critical Continuity™ Emerson Power Equipment And Environment Monitoring System Benefits Emerson Power Equipment and Environment Monitoring System is applicable to monitoring in real time and managing in unity power supply equipment (power system, battery, UPS, generator and low-voltage distributor), airconditioning equipment and environment(door alarm, temperature, humidity, smoke detection, water immersion, infrared and scene)in telecom exchanges and base stations After11-year development and optimization, Emerson monitoring system has become a total solution including hardware, software and transmission products. The monitoring solution can be customized to adapt to different regions, different maintenance management mechanisms, different exchanges and different transmission resources. The solution can meet the demands of monitoring the whole power equipment, environment of both fixed and mobile telecom networks Series Emerson power equipment and environment monitoring system Single version system Applications Power equipment and environment monitoring system Applicable to monitoring p ower equipment, environment in switch site, base stations,transmission relay stations Features Of Monitoring Center supervision center SC consists of database server, console, printer and auxiliary equipment The server collects, saves, analyzes and manages all monitoring data from monitoring end office SU. It gives various alarms (sound & light alarm, email, message, etc.) in case of monitored object's failure Real time alarms In case of monitored object's failure, the monitoring system can give alarm within 30 seconds Multiple alarm reports There are sound & light alarm, printed alarm, paging alarm,mobile short message alarm, E-mail alarm and voice alarm Flexible networking Flexible single or mixed networks can be set up through CE1, DDN/LL, ISDN, PSTN and WAN Supports maintenance management Provides maintenance anlysis data,improves maintenance efficiency and cuts maintenance cost Real time data collection The system operates around the clock and reports in real time the monitored equipment and environment's conditions. The system provides firsthand data to evaluate equipment conditions. Wide-range monitored objects The monitored objects include HV and LV distribution equipment, power system, air conditioning,diesel generator, battery and UPS; and also include environment data in relation to temperature, humidity, water immersion, smoke and door Fexible Transmission Networking Monitoring center SC, monitoring station SS and monitoring end office SU can form a wide area network through IP, 2M, DDN, ISDN, PSTN and WAN 49 Monitoring Communication Solution of Monitoring System IP Networking Features: Using the available TCP/IP network in site Supportive of HTTP, TELNET, FTP Remote debugging and upgrade Applicable to:IDC room, MSC room, 3G base station, GPRS and CDMA site Server Console LAN Host IP network IDU IDU IDU IDU IDU IDU Server Console LAN Host BRG-POOL E1 Emerson Power Equipment And Environment Monitoring Software V4.39 Emerson IP Video Monitoring Software 50 IDU IDU E1 IDU IDU IDU IDU Business-Critical Continuity™ Solution of large site The SU has IDU and sensors Applicable to: exchange station, switch centers ( MSC) Monitored equipment: HV and LV, generator diesel, AC distribution, rectifier, DC distribution, battery strings,DC converter, inverters and air-conditioner, it can also be applied to acquire theenvironment data, such as smoke detector, temperature and humidity sensor, access control andwater detector Generator Monitoring Center Transmission Low Voltage Distribution diesel level DC Power Intrusion detector For Door IDU-HOST Smoke Detector Battery Water Leakage Communication line Power line Temperature And Humidity Air Condition solution of small site The SU has IDU and sensors Applicable to: base station (BTS) Monitored equipment: Low Voltage, DC power, air-conditioner, temperature and humidity sensor, diesel level, smoke detector, door accessl and water detector Transmission IDU-HOST diesel level Intrusion detector Smoke Detector Water Leakage Temperature And Humidity DC Power Air Condition Power meter 51 Monitoring IDU series product specifications model BOM Description IDU-HOST 02311425 IDU host IDU-BAT1 02311434 IDU-BAT2 02311427 IDU-BRG1 02311438 IDU-BRG2 02311429 IDU-THS 33030018 Battery board 1 (1 battery group) Battery board 2 (2 battery groups) E1-IP network bridge communication board Double E1-IP network bridge communication board External THS temperature/ humidity sensor Functions 10 AI inputs (compatible with digital signals), 4 DI inputs, 1 THS temperature/humidity input channel, 4 relay outputs, with 4 serial ports, 2 battery group voltage channels, 1 Ethernet port, 1 USB port and 2 expansion slots Capable of monitoring 24 battery cells, 1 charge/discharge current, auto-switchover among measurement ranges of 2V, 6V and 12V capable of monitoring 48 battery cells, 2 charge/discharge currents, auto-switchover among measurement ranges of 2V, 6V and 12V 2 Ethernet ports (LAN), 1 E1 port (point-to-point, cannot be upgraded to double loop 2 Ethernet ports (LAN), 2 E1 ports (supportive of double loop) Temperature measurement range: -10 ℃~ 50 ℃ . Precision: +/-2℃ Humidity measurement range: 5 ~95%RH. Precision: +/-5% (20 ~ 80%RH, 25℃) IDU series product mechanical specifications Name IDU-HOST IDU-BAT1 IDU-BAT2 IDU-BRG2 BRG-POOL Sizes 440 ± 1mm × 295 ± 1mm × 44 ± 1mm 122 ± 1mm × 185 ± 1mm × 1.6mm 122 ± 1mm × 185 ± 1mm × 1.6mm 122 ± 1mm × 185 ± 1mm × 1.6mm 440 ± 1mm × 295 ± 1mm × 44 ± 1mm Weight ≤5kg ≤0.5kg ≤0.5kg ≤0.5kg ≤5kg The features of IDU include 52 IP-network based, supportive of TCP/IP and network protocols such as HTTP, TELNET, FTP, TFTP and DHCP TELNET remote debugging Highly integrated, with superb processing and storing ability of bottom data Integrated connection with multiple intelligent devices Low cost image monitoring solution (USB image and anti-burglary) High standard lightning protection for all ports. Built-in SPDs are used for all ports, with lightning protection ability 2-times higher than the international standard Hardware self-diagnostic ability, including detection of E1 cable status, detection of board insertion fault, and measurement of CPU usage Network management function: IP flux statistics, IP contradiction auto-detection, and network topology structure Remote on-line upgrading of software IP networking mode, supportive of transmission modes of double loop, ADSL and E1 Supportive of ADSL static IP address Business-Critical Continuity™ BRG-POOL BRG-POOL bridge pool ( BRG-POOL) is conversion device for E1-IP transfer function. It provides eight independent E1-IP transfer channels and can be flexibly configured through CONSOLE portaccording to the actual application conditions and meet the requirements of different networkingmodes BRG-POOL specifications model BRG-POOL model BRG-POOL parameters 10/100M, half/full-duplex self-adaptable, RJ45 port, Ethernet cable intercross function Voltage input range -38V -60Vdc Dimensions 440mm × 295mm × 44mm Transmission distance ~ Power <20W Weight < 5kg 100m max. 53 EMERSON NETWORK POWER. THE GLOBAL LEADER IN ENABLING BUSINESS-CRITICAL CONTINUITY.™ AC POWER CONNECTIVITY DC POWER EMBEDDED COMPUTING EMBEDDED POWER EMBEDDED POWER MONITORING OUTSIDE PLANT POWER SWITCHING & CONTROLS PRECISION COOLING RACKS & INTEGRATED CABINETS SERVICES SURGE PROTECTION Making power conversion easy for IT and communications equipment. We deliver a broad offering of Astec ® and Artesyn® solutions, including AC/DC and DC/DC power supplies , adapters,chargers and power accessories. EMBEDDED POWER.Yet another way Emerson Network power enables Business-Critical Continuity™. 54 Business-Critical Continuity™ GIE4805/2A/500-2 Mini Power System Key Features 1 U Height and designed for 19” racks Integrated Battery Low Voltage Disconnection function Key Benefits Space efficient solution with all functions integrated GIE4805/2A/500-2 Nominal system voltage: -48 V System rated output power @ - 54 V: 540 W Rectifier rated output power @ - 54 V: 270 W DC distribution branch Branch 1 10A(FUSE) Branch 2 10A(FUSE) Battery 10A(FUSE) AC input range: 90-264 V AC Safety EN 60950 Sub rack dimensions (H x W x D): 43 x 482 x240mm 55 Embedded Power GEPS4820F/01-10/22-EN Mini Power System Key Features 1 U Height and designed for 19”racks Integrated LVD and priority load Key Benefits Space effi cient solution with all functi ons integrated GEPS4820F/01-10/22-EN 56 Nominal system voltage: - 48 V System rated output power @ - 54 V: 1600 W Rectifier rated output power @ - 54 V: 800 W DC distribution branch Branch 1 10A(FUSE) Branch 2 20A(FUSE) Battery 20A(FUSE) AC input range: 90-290 V AC Safety EN 60950, UL 60950 Sub rack dimensions (H x W x D): 45.6 x 482.6 x 325mm Business-Critical Continuity™ GIE4815/2A/1.7KW Mini Power System Key Features 2 U Height and designed for 19”racks Integrated AC distribution, LVD and priority load Remote monitoring and dry contacts Key Benefits Space efficient solution with all functions integrated GIE4815/2A/1.7KW Nominal system voltage: - 48 V System rated output power @ - 54 V: 1700 W Rectifier rated output power @ - 54 V: 850 W DC distribution branch Branch 1,2 Branch 3 Branch 4,5 Battery 5A(FUSE) 10A(FUSE) 20A(FUSE) 50A(MCB) AC input range: 90-290 V AC Safety EN 60950, UL 60950 Sub rack dimensions (H x W x D): 88 x 483 x 350mm 57 Embedded Power GIE4815/3A/2.55KW Mini Power System Key Features 3 U Height and designed for 19”racks Remote monitoring and dry contacts Integrated AC distribution, surge protection, LVD and priority load Key Benefits Space effi cient solution with all functi ons integrated on one shelf Robust and well proven design for tropical climates Provides reliable DC supply GIE4815/3A/2.55KW Nominal system voltage: - 48 V System rated output power @ - 54 V: 2550 W Rectifier rated output power @ - 54 V: 850 W DC distribution branch Branch 1, Branch 2,3 58 10A(MCB) 20A(MCB) Branch 4, 50A(MCB) Battery 63A(MCB) AC input range: 90-290 V AC Safety EN 60950, UL 60950 Sub rack dimensions (H x W x D): 133 x 465 x 360mm Business-Critical Continuity™ GIE4820/3A/3.45KW Mini Power System Key Features 3 U Height and designed for 19”racks Remote monitoring and dry contacts Integrated AC distribution, surge protection, LVD and priority load Key Benefits Space efficient solution with all functions integrated on one shelf Robust and well proven design for tropical climates Provides reliable DC supply GIE4820/3A/3.45KW Nominal system voltage: - 48 V System rated output power @ - 54 V: 3450 W Rectifier rated output power @ - 54 V:1150 W DC distribution branch Branch 1, Branch 2,3 10A(MCB) 20A(MCB) Branch 4, 50A(MCB) Battery 63A(MCB) AC input range: 90-290 V AC Safety EN 60950, UL 609 50 Sub rack dimensions (H x W x D): 133 x 465 x 360mm 59