Open spaces for occupancies: d) Business, mercantile and storage buildings The open spaces around the building shall be not less than 4.5 m for heights up to 16 m, with an increase of the open spaces of 0.25 m for every increase of 1 m or fraction thereof in height above 16 m. Where these occur in a purely residential zone or in a residential with incidental shops line zone the open spaces may be relaxed. e) Industrial buildings The open spaces around the building shall be not less than 4.5 m for heights up to 16 m, with an increase of the open spaces of 0.25 m for every increase of 1 m or fraction thereof in height above 16 m. Minimum Accessibility Provisions in Different Building Occupancies Mercantile buildings Shops, malls, large multi-storey department stores and super markets, etc At least one trial room for each group of such facility. Where only one is provided, it shall be accessible. ELECTRICAL AND ALLIED INSTALLATIONS (INCLUDING LIGHTNING PROTECTION OF BUILDINGS AND SOLAR ENERGY UTILIZATION Mercantile, hotels, motels, assembly, industrial and institutional buildings 500 m sq. and above for buildings having connected load of: a) 50-1 000 kW 10 kWp or 5 percent of connected load whichever is higher b) Above 1 000 kW 50 kWp or 5 percent of connected load whichever is higher OFF-STREET PARKING SPACES Occupancy Population Less than 50000 Population Between 50 000 and 200 000 Population Between 200000 and 1000 000 Population Between 1000000 and 5 000 000 Population above 5 000 000 Mercantile 300 m2 area or fraction thereof 200 m2 area or fraction thereof 100 m2 area or fraction thereof 50 m2 area or fraction thereof 25 m2 area or fraction thereof ACCESS AT ENTRANCE AND WITHIN THE BUILDING General Requirements b) A clear, firm and level landing of at least 1 800 mm × 1 800 mm shall be provided on either side of the entrance door. c) The width of the accessible entrance door shall not be less than 900 mm and the width of the corridors or passageways leading to and from such access door shall not be less than 1 200 mm. d) In multi-storey buildings, the accessible entrance shall have an accessible route leading to the lifts. e) Internal floor surfaces shall be of materials that do not impede the movement of wheelchairs. If mat is provided it shall be in level with the floor finish. COMPARTMENTATION 6.6.1 Life Safety 6.6.1.1 Open air mercantile operations, such as open air markets, petrol filling stations, roadside stands for the sale of a farm produce and other outdoor mercantile operations shall be so arranged and conducted as to maintain free and unobstructed ways of travel at all timesto permit prompt escape from any point of danger in case of fire or other emergency, but no dead-ends in which persons might be trapped due to display stands, adjoining buildings, fences, vehicles or other obstructions. 6.6.1.2 If such mercantile operations are conducted in roofed-over areas, these shall be treated as mercantile buildings, provided canopies over individual small stands to protect merchandise from the weather shall not be construed to constitute buildings for the purpose of the Code. 6.6.2 Exception and Deviation Any mercantile occupancy, where goods of a highly hazardous nature are predominant, shall be considered under Group J occupancy for the purpose of the Code.