Wind turbine converters ABB small wind inverters PVI-3.0/3.6/4.2-OUTD-US-W 3 to 4.2 kW The PVI-3.0/3.6/4.2-TL-W wind turbine inverter is designed with ABB’s proven high performance technology. This dual stage transformerless wind turbine inverter offers a unique combination of high efficiency, installer-friendly design and very wide input voltage range ensuring high energy harvesting. Efficiency of up to 96.8% The PVI-3.0/3.6/4.2-TL-W features an efficiency up to 96.8 percent thanks to transformerless technology. The high speed and precise power curve tracking algorithm allows to best match the power curve of each turbine. It is a sealed unit to withstand harsh environmental conditions. It has power curve customization with high granularity, up to 16-point, for high production yield. Highlights − − Single phase output − − Power curve customization − − Wide input voltage range − − Transformerless technology − − Field-selectable grid standard settings Additional highlights −− Flexible data monitoring options to view inverter performance − − Compatible with ABB 7200-WINDINTERFACE − − Compatible with ABB 15/25kW-WINDINTERFACE Technical data and types Type code Nominal output power Maximum output power Input side Absolute maximum voltage (Vmax) Start-up voltage (Vstart) Full power voltage range Operating voltage range Maximum usable current Maximum short circuit current limit Wiring termination Output side Grid connection type Grid voltage range (Vmin-Vmax) Nominal grid frequency Adjustable grid frequency range Maximum current (Iacmax) Power factor Total harmonic distortion at rated power Grid wiring termination type Input protection devices Reverse polarity protection Overvoltage protection type Ground fault detection Output protection devices Anti-islanding protection Overvoltage protection type Efficiency Maximum efficiency Operating performance Stand by consumption Feed in power threshold PVI-3.0-OUTD-US-W 3000 W 3300 W 200-530 V 20.0 A 25.0 A PVI-3.6-OUTD-US-W 3600 W 4000 W PVI-4.2-OUTD-US-W 4200 W 4600 W 600 V 50 V (adj. 50-350 V) 220-530 V 200-530 V 200-530 V 220-530 V 200-530 V 200-530 V 50-580 V 32.0 A 32.0 A 40.0 A 40.0 A Terminal block 1Ø/2W Split-Ø/3W 1Ø/2W 1Ø/2W Split-Ø/3W 1Ø/2W 1Ø/2W Split-Ø/3W 1Ø/2W 183-228 V 211-264 V 244-304 V 183-228 V 211-264 V 244-304 V 183-228 V 211-264 V 244-304 V 60 Hz 57-63 Hz 14.5 A 14.5 A 12.0 A 17.2 A 16.0 A 16.0 A 20.0 A > 0.990 < 3.5 % Terminal block 2 ABB small wind inverters | Product flyer for PVI-3.0/3.6/4.2-OUTD-US-W Yes, passive protection only Varistor, 4 Pre start-up RISO and dynamic GFDI Meets UL1741/IEE1547 requirements Varistor, 2 (L 1-L2/L1-G) 96.8 % < 8.0 W 10.0 W Block diagram of PVI-3.0/3.6/4.2-OUTD-US-W IN1.1(+) Boost 1 (DC/DC) Inverter (DC/AC) Bulk caps IN1.2(+) Line Filter IN1.1(-) Grid parallel Relay L1 IN1.2(-) L3 IN1.1(+) Boost 2 (DC/DC) PE IN1.2(+) IN1.1(-) IN1.2(-) RS485 + T/R - T/R RTN DC/DC DSP contr. WT (+) DC/AC DSP contr. Remote control +R -R µP Wind speed input Alarm N.C WT (-) N.O C Control circuit Technical data and types Type code Communication User-interface Remote monitoring Wired local monitoring Wireless local monitoring Environmental Ambient air operating temperature range Ambient air storage temperature range Relative humidity Acoustic noise emission level Maximum altitude without derating Mechanical specifications Enclosure rating Cooling Dimensions (H x W x D) Weight Mounting system Safety Isolation level Safety and EMC standard Safety approval Warranty Standard Available models Standard PVI-3.0-OUTD-US-W PVI-3.6-OUTD-US-W PVI-4.2-OUTD-US-W 16 characters x 2 lines LCD display VSN300 Wifi Logger Card(*) (opt.), VSN700 Data Logger (opt.) PVI-USB-RS232_485 (opt.) VSN300 Wifi Logger Card(*) (opt.) -13 °F to + 140 °F (‘-25 °C to +60 °C) -13 °F to + 140 °F (‘-25 °C to +60 °C) -13 °F to + 140 °F (‘-25 °C to +60 °C) with derating above 130 °F (55 °C) with derating above 130 °F (55 °C) with derating above 113 °F (45 °C) -40 °F to + 176 °F (-40 °C to +80 °C) 0-100 % condensing <50 db(A)@1m 6560 ft (2000 m) NEMA 4X Natural convection 20.4 in x 14.4 in x 6.3 in (518 mm x 367 mm x 161 mm) 37.4 lb (17 kg) Wall bracket Transformerless UL Std. No. 1741 - 2nd Edition, IEE1547, CSA C22.2 107.1-01-2001, FCC Part 15 Sub-part B Class B limits cCSA us 5 PVI-3.0-OUTD-US-W PVI-3.6-OUTD-US-W PVI-4.2-OUTD-US-W Remark. Features not specifically listed in the present data sheet are not included in the product Check availability before to order Product flyer for PVI-3.0/3.6/4.2-OUTD-US-W | ABB small wind inverters 3 Efficiency curves of PVI-4.2-OUTD-US-W 100 100 99 99 98 98 97 97 96 96 Efficiency, % 95 94 93 95 94 93 200 Vdc 200 Vdc 92 480 Vdc 91 90 92 340 Vdc 0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 340 Vdc 480 Vdc 91 100% 90 0% 10% % of Rated Output Power Support and service ABB supports its customers with a dedicated, global service organization in more than 60 countries and strong regional and national technical partner networks providing the complete range of life cycle services. 20% 30% 40% 50% 60% % of Rated Output Power For more information please contact your local ABB representative or visit: www.abb.com/converters-inverters www.abb.com/windpower 70% 80% 90% © Copyright 2014 ABB. All rights reserved. Specifications subject to change without notice. 100% BCD.00429 NA 14.04.2014 Efficiency, % Efficiency curves of PVI-3.6-OUTD-US-W