CERTIFICATE OF ANALYSIS
ATCC Number:
VR-740™
Lot Number:
70053995
Classification:
Coronaviridae, Coronavirus
Agent:
Human coronavirus 229E
Strain:
229E
Passage History:
Submission laboratories: Human Embryonic Kidney (HEK) (2), WI-38 (11), Human
Embryonic Lung Fibroblasts (RU-1) (8), WI-38 (1)
ATCC: MRC-5 (1), MRC-5 (ATCC® CCL-171™) (4)
Fill Volume:
1.0 mL
Product Format:
Fluid and cell lysate from infected cultures
Expiration Date:
Not applicable
Storage Conditions:
- 70°C or colder
Test / Method
Specification
Result
Viability (Infectivity)*
PFU, IFU, TCID50 or CEID50 ≥ 5 ×
103 per mL
Pass
Authentication**
Virus identity verified by
Immunofluorescence, ELISA,
and/or sequencing
Pass
Test for Mycoplasma Contamination
Broth and agar culture (direct method)
DNA detection by PCR of test article nucleic acid
No growth
None detected
No growth
None detected
Sterility test (BacT/ALERT 3D)
iAST bottle (aerobic) at 32.5°C, 14-day incubation
iNST bottle (anaerobic) at 32.5°C, 14-day incubation
No growth
No growth
No growth
No growth
*Titer notes: 5.0 × 107 TCID50/mL in 8 days on MRC-5 cells (Homo sapiens lung fibroblast cells) at 35°C with 5% CO2 as
determined by cytopathic effect. Tested on 06OCT2022.
**Authentication notes: Genomic authentication was performed by Next Generation Sequencing (NGS) and results meet
requirements of ≥ 1000 bp with ≥ 98% homology to GenBank number AF304460.1 (Human Coronavirus 229E, complete genome)
Sonia Bjorum Brower
Digitally signed by Sonia Bjorum Brower
Date: 2022.12.13 16:26:30 -05'00'
Sonia Bjorum Brower
Technical Manager or designee, ATCC Federal Solutions
13 DEC 2022
ATCC hereby represents and warrants that the material provided under this certificate is pure and has been subjected to the tests and
procedures specified and that the results described, along with any other data provided in this certificate, are true and correct to the
best of the company’s knowledge and belief. This certificate does not extend to the growth and/or passage of any living organism or
cell line beyond what is supplied within the container received from ATCC.
ATCC
10801 University Boulevard
Manassas, VA 20110-2209 USA
www.atcc.org
Template Doc ID: 31194
- Page 1 of 2 Template Revision: 6
800-638-6597 or 703-365-2700
Fax: 703-365-2750
E-mail: tech@atcc.org
or contact your local distributor
Template Effective Date: 02/21/2020
CERTIFICATE OF ANALYSIS
ATCC Number:
VR-740™
Lot Number:
70053995
This product is intended to be used for laboratory research use only. It is not intended for use in humans, animals, or for
diagnostics. Appropriate Biosafety Level (BSL) practices should always be used with this material. Refer to the Product Information
Sheet for instructions on the correct use of this product.
ATCC products may not be resold, modified for resale, used to provide commercial services, or to manufacture commercial
products without prior written agreement from ATCC.
© 2017 ATCC. The ATCC trademark and trade name are owned by the American Type Culture Collection.
ATCC
10801 University Boulevard
Manassas, VA 20110-2209 USA
www.atcc.org
Template Doc ID: 31194
- Page 2 of 2 Template Revision: 6
800-638-6597 or 703-365-2700
Fax: 703-365-2750
E-mail: tech@atcc.org
or contact your local distributor
Template Effective Date: 02/21/2020