471841A.101 Nokia Flexi EDGE Base Station, Rel. EP2, Product Documentation, v.1 Nokia Flexi EDGE BTS System Module (ESMA) Description DN70247197 Issue 3 en 19/06/2008 # Nokia Siemens Networks 1 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description The information in this document is subject to change without notice and describes only the product defined in the introduction of this documentation. This documentation is intended for the use of Nokia Siemens Networks customers only for the purposes of the agreement under which the document is submitted, and no part of it may be used, reproduced, modified or transmitted in any form or means without the prior written permission of Nokia Siemens Networks. The documentation has been prepared to be used by professional and properly trained personnel, and the customer assumes full responsibility when using it. Nokia Siemens Networks welcomes customer comments as part of the process of continuous development and improvement of the documentation. The information or statements given in this documentation concerning the suitability, capacity, or performance of the mentioned hardware or software products are given “as is” and all liability arising in connection with such hardware or software products shall be defined conclusively and finally in a separate agreement between Nokia Siemens Networks and the customer. However, Nokia Siemens Networks has made all reasonable efforts to ensure that the instructions contained in the document are adequate and free of material errors and omissions. Nokia Siemens Networks will, if deemed necessary by Nokia Siemens Networks, explain issues which may not be covered by the document. Nokia Siemens Networks will correct errors in this documentation as soon as possible. IN NO EVENT WILL NOKIA SIEMENS NETWORKS BE LIABLE FOR ERRORS IN THIS DOCUMENTATION OR FOR ANY DAMAGES, INCLUDING BUT NOT LIMITED TO SPECIAL, DIRECT, INDIRECT, INCIDENTAL OR CONSEQUENTIAL OR ANY LOSSES, SUCH AS BUT NOT LIMITED TO LOSS OF PROFIT, REVENUE, BUSINESS INTERRUPTION, BUSINESS OPPORTUNITY OR DATA, THAT MAY ARISE FROM THE USE OF THIS DOCUMENT OR THE INFORMATION IN IT. This documentation and the product it describes are considered protected by copyrights and other intellectual property rights according to the applicable laws. The wave logo is a trademark of Nokia Siemens Networks Oy. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. Other product names mentioned in this document may be trademarks of their respective owners, and they are mentioned for identification purposes only. Copyright © Nokia Siemens Networks 2008. All rights reserved. 2 (41) # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 Contents Contents Contents 3 1 2 Summary of changes 5 Nokia Flexi EDGE System Module (ESMA) 7 3 System Module (ESMA) main blocks 13 4 4.1 System Module (ESMA) power requirements 15 System Module (ESMA) lightning protection 16 5 System Module (ESMA) interfaces 17 6 6.1 System Module (ESMA) dimensions and weight 25 Transmission sub-module dimensions and weight 26 7 System Module (ESMA) LED indications 27 8 8.1 8.2 8.3 8.6 8.7 8.8 Appendix: Contents of delivery 31 Contents of the System Module (ESMA) delivery 31 Contents of the transmission interface E1 sub-module (FIEA) delivery 31 Contents of the transmission interface Flexbus sub-module (FIFA) delivery 32 Contents of the transmission interface E1/T1 sub-module (FIPA) delivery 32 Contents of the transmission interface E1/T1 sub-module (FIQA) delivery 32 Contents of the transmission interface E1 sub-module (FIYA) delivery 33 Contents of the transmission cable deliveries (FTCx) 33 Contents of the transmission cable deliveries (FIQA FIYA) 34 9 9.1 Appendix: System Module connector pin assignments 37 System Module (ESMA) connector pin assignments 37 8.4 8.5 DN70247197 Issue 3 en 19/06/2008 # Nokia Siemens Networks 3 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description 4 (41) # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 Summary of changes 1 Summary of changes Changes between issues 3-0 and 2-0 Updated chapters: . Nokia Flexi EDGE System Module (ESMA) updated with information on FIYA and FIQA. Network interface alternatives in PWE and TDM mode added. . System Module (ESMA) main blocks Abis Over IP/Ethernet added to the bullet list. . System Module (ESMA) power requirements updated with power consumption figure for ESMA with FIQA and FIYA. A note added under ESMA lightning protection table. . EDGE System Module (ESMA) interfaces updated with information on FIYA and FIQA. Transmission interfaces added to the figure ESMA front panel connector and labels. . Transmission sub-module dimensions and weight updated with information on FIYA and FIQA dimensions and weight. . System Module (ESMA) LED indications updated with information on FIYA and FIQA. ESMA LEDs table updated. . Appendix: Contents of delivery delivery contents for transmission sub-modules and transmission cables added. . Appendix: System Module (ESMA) connector pin assignments pin assignments edited. Changes between issues 2-0 and 1-0 New chapters: . Summary of changes Updated chapters: DN70247197 Issue 3 en 19/06/2008 # Nokia Siemens Networks 5 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description 6 (41) . Nokia Flexi EDGE System Module (ESMA) edited and updated with information on the stand-by switch (PWR) on the front panel of the System Module power distribution unit. . System Module (ESMA) main blocks: FEPD information updated. . System Module (ESMA) power requirements updated with information on System Module (ESMA) lightning protection. FIFA power consumption information updated. . EDGE System Module (ESMA) interfaces information on EAC connector alarm outputs 5 & 6 added and locations of LEDs added to figures. Updated table FIPA transmission sub-module front panel connectors and interfaces. . System Module (ESMA) LED indications updated with information on ESMA power distribution sub-module (FEPD) LED indications. . Contents of the System Module (ESMA) delivery: information on connector rubber boots updated and pull-out tool added. # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 Nokia Flexi EDGE System Module (ESMA) 2 Nokia Flexi EDGE System Module (ESMA) The System Module (ESMA) is a unit providing BTS common functionalities and external and internal connections for the whole BTS. The BTS software is stored in the System Module. The System Module also receives and stores the unit identification information of all other units of the BTS. The System Module supports configurations of up to 12 TRXs. This equals to 6 x Dual TRX Modules (EXxA). For larger configurations, the System Extension Module (ESEA) is used along with the System Module. Note that one ESMA is always needed per BCF (object in BSC). The main functions of the System Module are: . BTS O&M . BTS integrated transport . Module bus control and BTS synchronisation . Power distribution (48 VDC) to other modules See the following figure for an isometric view of the System Module. DN70247197 Issue 3 en 19/06/2008 # Nokia Siemens Networks 7 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description DN70246295 Figure 1. Isometric view of the System Module (ESMA) BTS O&M Main BTS O&M functions are: . Software downloading (There can be simultaneously two software versions in a System Module) . Configuration management (BTS configuration autodetection) . Alarm handling and recovery . BTS reference clock management . External alarms and controls (EAC). The System Module provides 12 alarm input and six control output connections. When more than 12 alarm inputs are needed, a System External Alarm Module (FSEB) can be used BTS integrated transport The System Module handles external and internal transmission of the BTS. It has the physical transmission interfaces from the BTS to the BSC, and it terminates the Abis interface. There are four different network interface alternatives in TDM mode: 8 (41) . E1 symmetric 120 ohms, RJ48 . T1 symmetric 100 ohms, RJ48 # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 Nokia Flexi EDGE System Module (ESMA) . E1 asymmetric 75 ohms, SMB . Nokia FlexBus for Nokia microwave radios, TNC There are two different network interface alternatives in PW mode: . 100Base-T Ethernet (RJ48) . 1000Base-LX or 1000Base-SX optical Gigabit Ethernet (requires additional SFP module) These come as separate plug-in sub-module variants which are inserted into the System Module. There is space for one transmission sub-module in the System Module. For further information on Nokia Flexi EDGE BTS Pseudo-Wire Emulation (PWE) support, see Nokia Flexi EDGE BTS Commissioning. Table Alternative transport sub-modules and supported interfaces summarises the physical interfaces that the System Module integrated transport supports. Table 1. Alternative transport sub-modules and supported interfaces Sub-module type Interface Number of interfaces per System Module E1/T1 transmission submodule (FIPA) E1/T1 (symmetric) 8 E1 transmission sub-module (FIEA) E1 (asymmetric) 8 FlexBus transmission submodule (FIFA) FlexBus (integrated coaxial copper interfaces for Nokia microwave radios) 2 E1/T1 and PWE transmission E1/T1 (symmetric) sub-module (FIQA) 100Base-T Ethernet E1 and PWE transmission sub-module (FIYA) 4 2 (1 interface usable) 1000Base-LX or 1000BaseSX Ethernet 1 E1 (asymmetric) 4 100Base-T Ethernet 1000Base-LX or 1000BaseSX Ethernet 2 (1 interface usable) 1 An optional FlexiHub module is available for transmission enhancements. DN70247197 Issue 3 en 19/06/2008 # Nokia Siemens Networks 9 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description Following figures show the transmission sub-modules. DN70286497 Figure 2. Isometric view of the transmission sub-module FIPA DN70286516 Figure 3. Isometric view of the transmission sub-module FIEA DN70286504 Figure 4. 10 (41) Isometric view of the transmission sub-module FIFA # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 Nokia Flexi EDGE System Module (ESMA) DN70534826 Figure 5. Isometric view of the transmission sub-module FIQA DN70534841 Figure 6. DN70247197 Issue 3 en 19/06/2008 Isometric view of the transmission sub-module FIYA # Nokia Siemens Networks 11 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description Module bus control and BTS synchronisation The System Module has an integrated BTS internal and external synchronisation functionality. It can be synchronised to the incoming Abis line or to an external synchronisation source (other BTS or Location Measurement Unit, LMU). It distributes the clock signals within the BTS and can maintain clock synchronisation if the external synchronisation source is lost. The System Module also acts as a main communication link within the BTS and the connected modules (Dual TRX module, Remote Tune Combiner module) via the Module Bus. Power distribution The operating power is supplied to Nokia Flexi EDGE BTS from a single point in the System Module. The System Module distributes the 48 VDC power further to up to six other modules of the BTS. The power distribution capability can be increased with an additional System Extension Module. The main function of the System Extension Module is to increase the number of Dual TRX Module connections. There is a stand-by switch (PWR) on the front panel of the System Module power distribution unit. The switch is used for switching System Module unit power ON/Stand-by when DC input voltage is connected. When DC power is connected to the System Module, the default mode is "ON", even if the last mode was "Stand-by" when DC power was disconnected. Switching to "Stand-by" mode disables power to all Dual TRX Modules connected to the System Module. 12 (41) # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 System Module (ESMA) main blocks 3 System Module (ESMA) main blocks System Module (ESMA) includes the following functional blocks: . System control block . BTS O&M . TRS O&M . Transport network layer procedures . System Module control . System timing block . Common system reference frequency and air interface timing generation . BTS frame clock and frame number generation . Interface to Location Measurement Unit (LMU) . External synchronization I/O . System interfaces block . Ethernet switching of Gigabit/Fast Ethernet data . Interface to TRX and RTC Modules via Gigabit/Fast Ethernet (autonegotiation) . Local Management Port (LMP) interface . Fan control . Transport interfaces block This block is the transmission sub-module. . Interface to physical (electrical/RF) transport media . Timing reference extraction for BTS centralized timing . Controlled by transport block controller (concerns only the Flexbus interface sub-module) . Ethernet interface for Abis Over IP/Ethernet . DN70247197 Issue 3 en 19/06/2008 External interfaces block . External Alarms and Controls (EAC) interfaces . Visual indicators (LEDs) # Nokia Siemens Networks 13 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description . . Management interfaces to external units and site support system FPA (Flexi Power Alarm) interfaces . Power supply block . Module internal power supply . Power distribution unit (PDU or FEPD) . Power distribution to TRX Modules and RTC Modules . Power distribution to System Module internal sub-modules or units . Fuse protection of separate power supply interfaces Following figure presents the functional blocks of the System Module. FEPD POWER FAN TRAY FEPD FANs INTEGRAL PSM 6 x ALARM OUT Alarm Interface ALARM 12 x ALARM IN SS SS Q1 Q1 L2 switch & sync CORE BLOCK X-Connect LoopProtection Abis Term. LMP PLUG-IN: E 1/T1 symm. E1 coax. FEIB Abis Interface GE & Sync to DTRX LMP FlxA SYNC SOUT SIN SOUT SIN OCXO & CONTROL DN70246965 Figure 7. 14 (41) System Module main blocks # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 System Module (ESMA) power requirements 4 System Module (ESMA) power requirements Table 2. System Module (ESMA) power requirements Property Value Nominal system voltage 48 V DC Input voltage range 40.5 - 57 V DC Table 3. System Module (ESMA) maximum power consumption Module Maximum power consumption ESMA E1/T1 (FIPA, FIEA) 55 W ESMA E1/T1 (FIPA, FIEA) with LMU and FSEB 68 W ESMA Flexbus (FIFA) (includes two microwave radio units) 76 W ESMA Flexbus (FIFA) with LMU and FSEB 148 W ESMA E1/T1 & PW (FIQA) 55 W ESMA E1 & PW (FIYA) DN70247197 Issue 3 en 19/06/2008 # Nokia Siemens Networks 15 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description 4.1 System Module (ESMA) lightning protection Table 4. System Module (ESMA) lightning protection Interface Lightning surge level Telecom ports 0.5 kV 1.2/50 µs pulse (ETSI Type Approval requirement EN 301 489-1) Use only tested IP55 class cables with seals provided by Nokia Siemens Networks. The cable shielding must be connected to the relevant ground pins at the Digital Distribution Frame DDF/ NTU respectively Network Interface Unit NIU as close as possible in order to avoid EMC interfering effects. Additional county specific grounding regulations for Telecom wiring installations might apply! The FlexiBTS IuB/ Abis Telecom interface is a SELV circuit and must not be directly connected to TNV circuits. The Flexi IuB/ Abis interfaces can be connected to the telecommunication network only through a Network Terminating Unit NTU/ Network Interface Unit NIU that provides overvoltage protection and needed isolation. Control/EXT ports +/- 4 kV, 10/700 µs pulse, Rs=25 Ω (between center conductors and shield) Note that if the Flexi EDGE System Module (ESMA) or System Extension Module (ESEA) is located more than 10 meters (32.8 ft.) from the site support system in outdoor installations, then the Flexi System Over Voltage Protection (FSEC) (or other similar OVP) is required for the DC power feed. In this case, the OVP for the site support system does not protect the ESMA or ESEA module(s) from overvoltage spikes (e.g. caused by nearby lightning). For example, an FSEC (or other similar OVP) is required when Flexi EDGE BTS is installed at the top of a mast and the site support system is located at the bottom of the mast. In this case, the OVP for the site support system will not protect the Flexi EDGE BTS, therefore an FSEC or other OVP must be installed on or next to the BTS. 16 (41) # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 System Module (ESMA) interfaces 5 System Module (ESMA) interfaces Bus 5 Bus 3 PWR2/8 PWR4/10 Bus 4 PWR5/11 Bus 6/Out PWR3/9 Bus 2 Sync OUT PWR6/12 FEPD LED PWR PWR1/7 EAC V48 (+/-) Bus 1 SS Sync IN FPA Caution, Hot Surface LED (ESMA) Electrostatical sensitive device FIxA LED Interchangeable Transport module: 8xE1, 8xE1/T1, 2x Flexbus, 4xE1+2xFE+1xGE or 4xE1T1+2xFE+1xGE Q1 LMP Electrostatical sensitive device Figure 8. DN70247197 Issue 3 en 19/06/2008 DN7073143 Nokia Flexi EDGE System Module (ESMA) front panel connectors and labels # Nokia Siemens Networks 17 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description Table 5. Nokia Flexi EDGE System Module (ESMA) front panel connectors and interfaces Label name on module Function Connector type Interface(s) V48N (+/-) -48 V DC input power for the base station. M10 terminal bolts FPMA, FPDA, site support, or other external power supply PWR 1/7…PWR 6/12 -48 V DC output power with fuse Multi-Beam XL protection to six other modules. EXxA, ECxA, FCFA BUS 1…BUS 6/OUT 6 x Ethernet (1000 Base-T) MDR 26 F RA EXxA, ECxA, ESEA EAC* External alarm and control interface MDR 36 F RA FSEB, FSAA, customer alarm inputs or control outputs Sync OUT Base station synchronisation chaining out MDR 14 F RA External BTS Sync IN Base station synchronisation chaining in MDR 26 F RA External BTS, LMUB SS Site Support alarm RJ45 - FPA Flexi power alarm RJ45 shielded FPAA, FPBA, FPDA Q1 Q1 management interface RJ45 shielded Nokia Q1 managed network elements LMP Local management port RJ45 shielded Laptop or other computer External 2Mhz (only in PW mode) * The alarm outputs 5 & 6 are open collector circuits. The outputs are in floating state with no load (relays not connected). Load is needed for output testing. Usually relays are connected between the alarm outputs and the alarm power supply outputs 5 & 6. 18 (41) # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 System Module (ESMA) interfaces Transmission interface E1 sub-module (FIEA) interfaces 2M signal input 2M signal output 2M signal input 2M signal output ground ground ground ground Tx8 Rx8 Tx6 Rx6 Tx7 Rx7 Tx3 Rx3 Tx5 Rx5 Tx4 Rx4 Tx1 Rx1 Tx2 Rx2 LED Electrostatical sensitive device DN70165032 Figure 9. Table 6. FIEA transmission sub-module front panel connectors and labels FIEA transmission sub-module front panel connectors and interfaces Label name on module Description Connector type Interface(s) Tx1 Rx1...Tx8 Rx8 SMB External transmission equipment DN70247197 Issue 3 en 19/06/2008 Eight Transmission (Abis) interfaces - unbalanced (coaxial) E1 # Nokia Siemens Networks 19 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description Transmission interface Flexbus sub-module (FIFA) interfaces LED LED FB1 LED FB2 Electrostatical sensitive device Figure 10. Table 7. DN70165044 FIFA transmission sub-module front panel connectors and labels FIFA transmission sub-module front panel connectors and interfaces Label name on module Description Connector type Interface(s) FB1, FB2 TNC Nokia FlexiHopper microwave radios 20 (41) Transmission (Abis) interface Flexbus (Nokia proprietary PDH radio) # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 System Module (ESMA) interfaces Transmission interface E1/T1 sub-module (FIPA) interfaces 876 54321 IF8 IF7 IF6 IF5 1 2 3 4 5 6 In In + Gnd Out Out + Gnd IF4 IF3 IF2 IF1 LED Electrostatical sensitive device Figure 11. Table 8. DN70165056 FIPA transmission sub-module front panel connectors and labels FIPA transmission sub-module front panel connectors and interfaces Label name on module Description Connector type Interface(s) IF1 ... IF8 RJ48 shielded External transmission equipment DN70247197 Issue 3 en 19/06/2008 Eight transmission (Abis) interfaces - balanced E1/T1 # Nokia Siemens Networks 21 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description Transmission interface E1/T1 sub-module (FIQA) interfaces IF4 IF2 EIF3 EIF1 FIQA IF3 EIF2 IF1 Electrostatical sensitive device LED Caution, Hot Surface DN70540929 Figure 12. FIQA transmission sub-module front panel connectors and labels Table 9. FIQA transmission sub-module front panel connectors and interfaces Label name on module Description Connector type Interface(s) IF1 ... IF 4 Four transmission (Abis) interfaces balanced E1/T1 RJ48 shielded External transmission equipment PWE mode: Configurable E1 signal as synchronization input (IF1 ... IF4) -E1 signal as synchronization output (IF4 only) Note that the synchronization output is not configurable 22 (41) # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 System Module (ESMA) interfaces Table 9. FIQA transmission sub-module front panel connectors and interfaces (cont.) Label name on module Description Connector type Interface(s) EIF1 ... EIF2 Two PWE transmission (Abis) interfaces 100Base-T (Fast Ethernet) RJ48 shielded Ethernet/IP based packet switched network EIF3 One PWE transmission (Abis) interfaces 1000Base-SX or 1000Base-LX (Gigabit Ethernet) requires additional SFP module SFP connector/cage Ethernet/IP based packet switched network The FIQA PWE channels do not support T1 operation mode. Transmission interface E1 sub-module (FIYA) interfaces Tx4 Rx4 EIF3 Tx2 Rx2 EIF1 FIYA Tx3 Rx3 Tx1 Rx1 EIF2 Electrostatical sensitive device LED Caution, Hot Surface Figure 13. DN70247197 Issue 3 en 19/06/2008 DN70540932 FIYA transmission sub-module front panel connectors and labels # Nokia Siemens Networks 23 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description Table 10. FIYA transmission sub-module front panel connectors and interfaces Label name on module Description Connector type Interface(s) Tx1 RX1 ... Tx4 Rx4 Four Transmission (Abis) interfaces unbalanced (coaxial) E1 SMB External transmission equipment Ethernet/IP based packet switched network PWE mode: Configurable E1 signal as synchronization input (Tx1 Rx1..Tx4 Rx4) -E1 signal as synchronization output (Tx4 Rx4 only) 24 (41) EIF1 ... EIF2 Two PWE transmission (Abis) interfaces 100Base-T (Fast Ethernet) RJ48 shielded EIF3 One PWE transmission (Abis) interfaces 1000Base-SX or 1000Base-LX (Gigabit Ethernet) requires additional SFP module SFP connector/cage Ethernet/IP based packet switched network # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 System Module (ESMA) dimensions and weight 6 System Module (ESMA) dimensions and weight The dimensions of the Flexi EDGE System Module are presented in the table below. Table 11. ESMA dimensions and weight Property Width 1) Value 447/492 mm (17.6/19.4 in.) Height 133 mm (5.2 in.) Depth 2) 422/560 mm (16.6/22.1 in.) Weight without transmission sub-modules 8.6 kg (19 lbs) 1) Width of the casing without front covers/with front covers 2) Depth of the casing without front covers/with front covers Maximum dimensions of the module without a casing or cover are: Front panel width 483 mm (19 in.), module width less than 447 mm (17.6 in.) and depth less than 432 mm (17 in.) DN70247197 Issue 3 en 19/06/2008 # Nokia Siemens Networks 25 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description 6.1 Transmission sub-module dimensions and weight The dimensions of the transmission sub-modules (FIEA, FIFA, FIPA) are presented in the table below. Table 12. Transmission sub-module dimensions and weight Property Value Width 262 mm (10.3 in.) Height 40 mm (1.6 in.) Depth 165 mm (6.5 in.) Weight FIPA 0.63 kg (1.3 lbs) FIEA 0.65 kg (1.4 lbs) FIFA 0.81 kg (1.7 lbs) The dimensions of the transmission sub-modules (FIQA, FIYA) are presented in the table below. Table 13. Transmission sub-module dimensions and weight Property Value Width 265 mm (10.4 in.) Height 40 mm (1.6 in.) Depth 195 mm (7.6 in.) Weight 26 (41) FIQA 0.9 kg (1.9 lbs) FIYA 0.97 kg (2.1 lbs) # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 System Module (ESMA) LED indications 7 System Module (ESMA) LED indications System Module (ESMA) has one tri-colour LED on the front panel to indicate the operational status of the module and all fault conditions during operation. Table 14. ESMA LED indications Colour Explanation Stable red BTS_OM SW is not running BCF/TRS critical alarm (except during platform startup), or BCF reset Blinking red BCF/TRX major alarm (except during platform startup or BCF reset) Stable yellow BCF is locked (except during platform startup or BCF reset) Normal mode: BCF SW is loading (OMU signal off); BCF is configuring (OMU signal off) Blocked BCF: BCF is in supervisory mode or background SW loading Blinking yellow Platform startup Normal mode: auto detection in progress; BCF is commissioning or waiting for LDAP; BCF is configuring (OMU signal on) Local module: auto detection in progress; BCF is commissioning or configuring Stable green Normal mode: BCF is in supervisory mode; BCF background SW is loading (OMU signal off) Local mode: BCF is in supervisory mode Blinking green Normal mode: BCF SW is loading or background SW is loading (OMU signal on) Local mode: BCF background SW is loading Cycling colours DN70247197 Issue 3 en 19/06/2008 BCF Highlight # Nokia Siemens Networks 27 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description The difference between background SW is loading and BCF SW is loading is that BCF SW loading is what happens in BTS startup (after BCF/BTS reset (SW/HW reset)). The background SW is loading is what happens during runtime, for example, calls maybe on going. Tables below describe the transmission sub-module LED indications: Table 15. FIPA/FIEA LED indications Colour Explanation Dark Power off Stable red Interface card has power but it is not detected Stable green Interface card is detected by the System Module Table 16. FIFA main status LED indications Colour Explanation Stable red One or more data lines are not operating correctly, or The fault is in the indoor unit, outdoor units, or far-end units. Stable yellow The indoor unit, outdoor units, or far-end units have active alarm(s). (LED will be stabilized for alarm status in about 30s after power on) The data is transmitted in this configuration, but may not be transmitted in other configurations or if another failure occurs. The overall performance capability is reduced., or SW boot (LED is yellow only during the first second after power on. Afterwards LED blinks all colours during application SW startup). Stable green Both terminals over this hop are operating normally and no alarms are active A blinking green LED indicates that there is a connection to the node manager All colours blinking 28 (41) Application SW startup # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 System Module (ESMA) LED indications Table 17. FIFA Flexbus status LED indications Colour Status Dark No power feed or Tx signal (IU-IU connection can be active, however) Blinking green DC power feed to the outdoor unit active, Tx signal not active Stable green DC power feed to the outdoor unit and Tx signal active Table 18. FEPD LED indications Colour Status Red Transitional (shutdown or startup) Fault condition (over-current, output short circuit on any output, low input voltage, high input voltage) DN70247197 Issue 3 en 19/06/2008 Green Operating normally Yellow Stand-by # Nokia Siemens Networks 29 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description 30 (41) # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 Appendix: Contents of delivery 8 Appendix: Contents of delivery 8.1 Contents of the System Module (ESMA) delivery Table 19. Description Product code Quantity System Module (ESMA): 470246A 1 . . . 8.2 M5 screws 4 AWG 4/2 (25/35 mm2) connector rubber boots 2 Pull-out tool 1 Contents of the transmission interface E1 submodule (FIEA) delivery Table 20. Flexi transmission interface E1 asymmetrical sub-module (FIEA) delivery contents Description Product code Quantity Flexi transmission interface E1 asymmetrical submodule (FIEA): 470247A . DN70247197 Issue 3 en 19/06/2008 Nokia Flexi EDGE System Module (ESMA) delivery contents Screws (pre-installed) # Nokia Siemens Networks 1 4 31 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description 8.3 Contents of the transmission interface Flexbus sub-module (FIFA) delivery Table 21. Description Product code Quantity Flexi transmission interface Flexbus sub-module (FIFA): 471007A 1 . 8.4 Flexi transmission interface Flexbus sub-module (FIFA) delivery contents 4 Screws (pre-installed) Contents of the transmission interface E1/T1 submodule (FIPA) delivery Table 22. Flexi transmission interface E1/T1 symmetrical sub-module (FIPA) delivery contents Description Product code Quantity Flexi transmission interface E1/T1 symmetrical sub- 470248A module (FIPA): . 8.5 1 4 Screws (pre-installed) Contents of the transmission interface E1/T1 submodule (FIQA) delivery Table 23. Flexi transmission interface E1/T1 and PWE symmetrical submodule (FIQA) delivery contents Description Product code Quantity Flexi transmission sub-module FIQA: 471607A 1 PW 100Base-T Ethernet (RJ48) + 4xE1/T1 symmetrical 120/100 ohm (RJ48) + optional optical GE (SFP) 32 (41) # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 Appendix: Contents of delivery Table 23. Flexi transmission interface E1/T1 and PWE symmetrical submodule (FIQA) delivery contents (cont.) Description . 8.6 Product code Quantity 4 Screws (pre-installed) Contents of the transmission interface E1 submodule (FIYA) delivery Table 24. Flexi transmission interface E1 and PWE asymmetrical sub-module (FIYA) delivery contents Description Product code Quantity Flexi transmission sub-module FIYA: 471719A 1 PW 100Base-T Ethernet (RJ48) + 4xE1 asymmetrical 75 ohm (SMB) + optional optical GE (SFP) . 8.7 Contents of the transmission cable deliveries (FTCx) Table 25. DN70247197 Issue 3 en 19/06/2008 4 Screws (pre-installed) FTCA/FTCB transmission cable deliveries (used with the E1/T1 transmission sub-module FIPA) Description Product code Quantity FTCA OD Cable RJ48C – TQ-M/0 120 ohm 5 m (16.4 ft) 470312A 1 FTCB OD Cable RJ48C 120ohm 15 m (49.2 ft) 470309A 1 # Nokia Siemens Networks 33 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description Table 26. Description Product code Quantity FTCD OD Cable SMB-F/0 - BT43-F/0 75 ohm 5 m (16.4 ft) 470313A 1 FTCE OD Cable SMB-F/0 75 ohm 15 m (49.2 ft) 470310A 1 Table 27. 8.8 FTCD/FTCE transmission cable deliveries (used with the E1 transmission sub-module FIEA) FTCJ transmission delivery (used with the Flexibus transmission sub-module FIFA Description Product code Quantity FTCJ OD Cable TNC-F/0-TNC-M/0 2.5 m (8.2 ft) 471391A 1 Contents of the transmission cable deliveries (FIQA FIYA) Table 28. Transmission cable deliveries (used with the transmission submodules FIQA and FIYA) Description Cable TDM (E1/T1 cables) TDM cables for FIPA can be used for FIQA in TDM mode Product code Quantity 1 TDM cables for FIEA can be used for FIYA in TDM mode Fast Ethernet cables Gigabit Ethernet long-haul Fiber (for Gigabit Ethernet according 1000Base-LX standard) SFP 34 (41) FTCR OD Cable RJ45 CAT5E 15m 471408A 1 FTCS OD Cable RJ45 CAT5E 30m 471717A 1 FTCT OD Cable RJ45 CAT5E 50m 471718A 1 FTCH OD Cable LC SM 1310 15 m 470311A 1 FOSC Flexi Optical Telecom SFP GbE 1310nm SM 471880A 1 # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 Appendix: Contents of delivery Table 28. Description Transmission cable deliveries (used with the transmission submodules FIQA and FIYA) (cont.) Cable Product code Quantity Gigabit Ethernet short-haul FSFB Flexi System Fibre B 50m Fiber (for Gigabit Ethernet FSFC Flexi System Fibre G 100m according 1000Base-SX standard) FSFF Flexi System Fibre F 10m 471395A 1 FSFG Flexi System Fibre G 20m 471708A 471709A FSFI Flexi System Fibre I 40m 471710A FSFK Flexi System Fibre K 75m 471711A FSFD Flexi System Fibre D 4m DN70247197 Issue 3 en 19/06/2008 471707A FSFH Flexi System Fibre H 30m FSFP Flexi System Fibre P 200m SFP 471396A 471712A 471743A FSFO Flexi System Fibre HF 2m 471851A FSFQ Flexi System Fibre HF 50m 471852A FOSD Flexi Optical Telecom SFP GbE 850nm MM 471881A # Nokia Siemens Networks 1 35 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description 36 (41) # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 Appendix: System Module connector pin assignments 9 9.1 Appendix: System Module connector pin assignments System Module (ESMA) connector pin assignments The pin assignments for the connectors on the System Module front panel are described in the tables below. Table 29. DN70247197 Issue 3 en 19/06/2008 EAC connector pin assignments Signal Pin Pin Signal EXT_CO0 1 19 +5V/150mA EXT_CO1 2 20 +5V/150mA EXT_CO2 3 21 +5V/150mA EXT_CO3 4 22 +5V/150mA EXT_CO4 5 23 +5V/CAN_L EXT_CO5 6 24 +5V/CAN_H EXT_AL0 7 25 GND EXT_AL1 8 26 GND EXT_AL2 9 27 GND EXT_AL3 10 28 GND EXT_AL4 11 29 GND EXT_AL5 12 30 GND EXT_AL6 13 31 GND EXT_AL7 14 32 GND EXT_AL8 15 33 GND EXT_AL9 16 34 GND EXT_AL10 17 35 GND # Nokia Siemens Networks 37 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description Table 29. Signal Pin Pin Signal EXT_AL11 18 36 GND Table 30. TRX connector pin assignments Signal PIN PIN Signal Signal Groups TRXMD 1 14 GND TRX Module Detection / GND GND_SFCRT 2 15 SFCRTN+ SF Bn+ 3 16 SFCRTn- System frame return reserv. SF Bn- 4 17 GND_SFB System Frame Burst GND_D 5 18 TPn_BI_DD+ TPn_BI_DC+ 6 19 TPn_BI_DD- TPn_BI_DC- 7 20 GND_C GND_B 8 21 TPn_BI_DB+ TPn_BI_DA+ 9 22 TPn_BI_DB- TPn_BI_DA- 10 23 GND_A GND 11 24 NC SCLKn+ 12 25 GND_TRXMD Ground for TRX detect SCLKn- 13 26 GND_SCLK Table 31. 38 (41) EAC connector pin assignments (cont.) Gigabit Ethernet (1000Base-T) System Clock (6.5 MHz) SIN connector pin assignments Signal PIN PIN Signal PPS_INP 1 14 Not connected # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 Appendix: System Module connector pin assignments Table 31. Signal PIN PIN Signal PPS_INN 2 15 Not connected FN_INP 3 16 GND FN_INN 4 17 SCD FCK_INP 5 18 GND FCK_INN 6 19 REF2M_OUT REF2M_IN 7 20 GND Creepage 8 21 Not connected LMU48V 9 22 LMU48VRTN LMU48V 10 23 LMU48VRTN Creepage 11 24 Not connected TSTCLK 12 25 TSTFCLK (REF10M_IN) 13 26 GND Table 32. Sync OUT connector pin assignments Signal PIN PIN Signal PPS_OUTP 1 8 Not connected PPS_OUTN 2 9 Not connected FN_OUTP 3 10 GND FN_OUTN 4 11 TSTCLK FCK_OUTP 5 12 GND FCK_OUTN 6 13 TSTFCLK REF2M_OUT 7 14 GND Table 33. DN70247197 Issue 3 en 19/06/2008 SIN connector pin assignments (cont.) Q1 connector pin assignments PIN Signal Function Technology Direction 1 NC Not connected - - 2 NC Not connected - - 3 Q1_OUT_P Q1 out plus RS-485 Output # Nokia Siemens Networks 39 (41) Nokia Flexi EDGE BTS System Module (ESMA) Description Table 33. PIN Signal Function Technology Direction 4 Q1_IN_P Q1 in plus RS-485 Input 5 Q1_IN_N Q1 in negative RS-485 Input 6 Q1_OUT_N Q1 out negative RS-485 Output 7 NC Not connected - - 8 NC Not connected - - Table 34. LMP connector pin assignments Pin Signal Function Technology Direction 1 LMP_RX+ Receive positive 10/100 base-TX In 2 LMP_RX- Receive negative 10/100 base-TX In 3 LMP_TX+ Transmit positive 10/100 base-TX Out 4 NC - - - 5 NC - - - 6 LMP_TX- Transmit negative 10/100 base-TX Out 7 NC - - - 8 NC - - - Table 35. 40 (41) Q1 connector pin assignments (cont.) SS connector pin assignments PIN Signal Function Technology Direction 1 SS_BI_DA+ GE TP A positive 10/100 base-TX Bidirectional 2 SS_BI_DA- GE TP A negative 10/100 base-TX Bidirectional 3 SS_BI_DB+ GE TP B positive 10/100 base-TX Bidirectional 4 SS_BI_DC+ GE TP C positive 10/100 base-TX Bidirectional 5 SS_BI_DC- GE TP C negative 10/100 base-TX Bidirectional 6 SS_BI_DB- GE TP B negative 10/100 base-TX Bidirectional 7 SS_BI_DD+ GE TP D positive 10/100 base-TX Bidirectional 8 SS_BI_DD- GE TP D negative 10/100 base-TX Bidirectional # Nokia Siemens Networks DN70247197 Issue 3 en 19/06/2008 Appendix: System Module connector pin assignments Table 36. DN70247197 Issue 3 en 19/06/2008 FPA connector pin assignments PIN Signal 1 FPA4 2 FPA5 3 FPA6 4 FPA1 5 FPA2 6 FPA3 7 GND 8 FPADET # Nokia Siemens Networks 41 (41)