TOC_EQ: 9-Aug-23 Vendor to delete Korean language. Only show English on drawing Apply the Company General comments applicable form G.A. drawing for 50-E-5102 (B01-50-SCJV-MC-5000090032-002) TOC_EQ: 9-Aug-23 G eneral Com m ent 1 , Vendor to add c ov er p age for this doc um ent 2, D elete c loud and hold item SCJV 24-Jul-23 20 RECEIVED TOC_EQ: 9-Aug-23 Vendor to add P ad for lifting lug on head TOC_EQ: 9-Aug-23 1 /8 " p er A2.0 1 3 Please spec ify E L Please Update 3D model after comfirmation Please spec ify u n it. Is it k g or k N ? Please prov ide b u n dle forc e for main ten an c e c ase Please select one unit kg or kN Please c h ec k forc e, th ey are same in 3 direc tion N Please modify north mark -plot plan comment- TOC_EQ: 9-Aug-23 Vendor to add 2 note for S /T heat ex c hanger: 21 , EX TER N AL P AIN TIN G : EQU IP M EN T P AIN TIN G S H AL L B E AP P L IED AS P ER R L P P -CH ES -0 0 0 0 1 , R L P P -CH ES -0 0 0 0 3, and 1 0 5 0 -CH ES -0 0 0 0 3 22, All shell and head attac hm ents, inc luding noz z le nec k s, reinforc ing p ads and struc tural attac hm ents hall c lear weld seam s b y a m inim um 5 0 m m . W hen unav oidab le, the seam shall b e ground flush and 1 0 0 % radiograp hed to a m inim um of 5 0 m m b eyond eac h side of interfered sec tion. TOC_EQ: 9-Aug-23 Vendor to add Im p ac t Test req uirem ent A2 M EAN TOC_EQ: 9-Aug-23 M aterial need to c hec k again M D M T is 1 0 deg C, so norm aliz e m aterial will b e not ap p lied