Uploaded by Saul Colocho

2022-12-02 Million Air Progress Set - Plumbing

advertisement
TAG
DCP-1
TP-2
WH-1,2
XT-1
PLUMBING FIXTURE SCHEDULE
MINIMUM ROUGH IN CONNECTION SIZE
SPECIFICATION
CW
HW
DRAIN
COMMENTS
ELECTRIC
TAG
-
TRAP PRIMER, ELECTRONIC: PPP MODEL DTS-4 MOUNTED
CABINET WITH PRIME COAT ACCESS DOOR, FOUR TRAP
PRIMER LINE OUTLETS.
1/2"
WATER HEATER: HTP PHOENIX PH199-119, COMMERCIAL
WATER HEATER. 119 GAL, STAINLESS STEEL TANK,
MODULATING BURNER, NATURAL GAS FIRED, 237 GPH
RECOVERY @ 100° F RISE. PROVIDE ACID NEUTRALIZATION KIT.
3/4"
EXPANSION TANK: AMTROL THERM-X-TROL. ST-12C-DD, 6.4
GALLON, 3/4"NPT CONNECTION
3/4"
3/4"
3/4"
-
-
-
3/4"
OUT
120V, 6W
TRAP PRIMER, SURFACE
T&P
RELIEF
VALVE
208V, 4 KW,
33.3AMPS
-
-
-
3 YEARS COMMERCIAL TANK WARRANTY.
NEUTRALIZATION KIT, PIPE IW TO MOP
RECEPTOR SEE DETAIL 2/P3.0. SET AT 140°F.
MASS APPROVAL CODE P3-0818-56
GAS INPUT
(CFH)
EQUIPMENT SERVED
PIPE
LENGTH (LF)
FITTING
EQUIVALENT
LENGTH (LF)
TOTAL
EQUIVALENT
LENGTH (LF)
GAS PIPE SIZE
RTU-1
GAS ROOFTOP UNIT
350
75'
65'
140'
2" BRANCH MAINS
GUH-1
GAS UNIT HEATER
260
80'
60'
140'
11/4" BRANCH
GUH-2
GAS UNIT HEATER
260
80'
60'
140'
11/4" BRANCH
GUH-3
GAS UNIT HEATER
260
75'
50'
125'
11/4" BRANCH
GUH-4
GAS UNIT HEATER
260
125'
50'
175'
11/4" BRANCH
ERU-1
GAS ENERGY RECOVERY UNIT
125
70'
50'
120'
1" BRANCH
WH-1
WATER HEATER
199
120'
50'
170'
11/4" BRANCH
WH-2
WATER HEATER
199
120'
50'
170'
11/4" BRANCH
1,913
125'
50'
175'
4" MAIN HEADER
TOTAL
LONGEST RUN IS TO GUH-1
LAV-1
3.2 GALLON ACCEPTANCE VOLUME
GAS EQUIPMENT LOAD & SIZING SCHEDULE
TAG
TMV-1
LEONARD POINT OF USE THERMOSTATIC MIXING VALVE MODEL
170-LF-BP-CP CHROME PLATED BRASS FINISH, LEAD FREE.
MINIMUM 0.25 GPM, MAXIMUM 4.0 GPM AT 5 PSI DROP MAX.
MB-1
MOP SINK: FIAT SBC3636 MOLDED STONE MOP RECEPTOR
COMPLETE WITH 830AA SERVICE SINK FAUCET, 889CC MOP
HANGER BRACKET, 1239BB ALUMINUM BUMPERGUARD WITH
VINYL INSERT AND MSG3636 WALL GUARD
PLUMBING SPECIALTIES SCHEDULE
MINIMUM ROUGH IN CONNECTION SIZE
SPECIFICATION
CW
HW
S OR W
V
COMMENTS
BFP-1
BACKFLOW PREVENTER: WATTS 2" LF009-QT CAST COPPER,
LEAD-FREE, W/ QUARTER TURN BALL VALVES.
2"
-
-
-
MAIN WATER ENTRANCE
BFP-2
BACKFLOW PREVENTER: WATTS 1" LF009-QT CAST COPPER,
LEAD-FREE, W/ QUARTER TURN BALL VALVES.
1"
-
-
-
WATER SERVICE COFFEE KIOSK
HOSE BIBB: CHICAGO FAUCET 952-1/2CP HOSE BIBB WITH
ATMOSPHERIC VACCUM BREAKER, 1/2" NPT FEMALE THREADED
INLET,3/4" MALE HOSE THREAD OUTLET AND TEE HANDLE.
1/ "
2
HB-A
-
FD-B
FLOOR DRAIN : WATTS FD-100-B-7 CAST IRON FLOOR DRAIN WITH
HEAVY DUTY NICKEL BRONZE STRAINER AND TRAP PRIMER
CONNECTION
-
FS-1
FLOOR SINK: ZURN ZN1900-P-2 CAST IRON FLOOR SINK, 12"x12"x6"
DEEP LIGHT DUTY NB GRATE AND RIM, HALF GRATE, ACID
RESISTANT COATING, TRAP PRIMER CONNECTION, ALUMINUM
BUCKET
-
WCO
WALL CLEANOUT: ZURN Z1441 WALL CLEANOUT PLUG WITH
COVER
FCO
FLOOR CLEANOUT : WATTS CO20 CAST IRON ADJUSTABLE FLOOR
CLEANOUT W/ ROUND TOP
GCO
GRADE CLEANOUT: ZURN Z1400-S-VP CAST IRON ON-GRADE
FLOOR CLEANOUT
FD-A
-
-
WB-1
WASHING MACHINE BOX: GUY GRAY MODEL BB200TS
GALVANIZED STEEL
1/ "
2
WATER SUPPLY BOX: WATER-TITE 87978 SQUARE WATER OUTLET
BOX WITH LEAD FREE QUARTER TURN VALVE WITH ARRESTER.
PROVIDE BRAIDED S.S. CONNECTOR.
1/ "
2
TP-1
TRAP PRIMER: PRECISION PLUMBING PRODUCTS PRO1-ULP500
LEAD FREE
1/ "
2
WH-1
ELECTRIC WATER HEATER: A.O. SMITH DURA-POWER DEL20
COMMERCIAL ELECTRIC WATER HEATER, 20 GALLON, 150 PSI
WORKING PRESSURE, HIGH DENSITY ANODE ROD, GLASSLINED,
ZINC PLATED COPPER SHEATH HEATING ELEMENT, THERMOSTAT
AND HIGH TEMPERATURE CUTOFF SWITCH, BACKED ENAMEL
OUTER JACKET, FOAM INSULATION. 18GPH @ 90° RISE. HOLDRITE
50-SWHP-WM . WALL-HUNG PLATFORM 26-1/2″X26-1/2″X2-1/2″,
STEEL DRAIN
-
PROVIDE P-TRAP WITH TRAP PRIMER
CONNECTION
2"
REFER
TO
PLANS
REFER
TO
PLANS
SK-2
-
4"
1-11 FIXTURE UNITS,
BASED ON PDI STANDARDS
3/ "
4
3/4"
SK-1
PROVIDE 1/2" CW TRAP PRIMER WATER LINE
CONNECTION TO FLOOR DRAIN.
2"
3"
-
PROVIDE 1/2" CW TRAP PRIMER WATER LINE
CONNECTION TO FLOOR DRAIN.
2"
3"
-
PROVIDE (1) HB EACH MOUNTED 1'-6" AFF
UNDER THE LAV OF THE MEN'S AND
WOMEN'S ROOMS.
-
2"
-
-
SHOCK ABSORBER / WATER HAMMER ARRESTOR: ZURN
Z-1700-100 SHOKTROL WATER HAMMER ARRESTOR.
WSB-1
-
-
SA-1
-
SH-2
1/ "
2
11/2"
2"
-
-
T&P
RELIEF
VALVE
3/4" OUT
-
UR-1
SEE DETAIL 6/P3.01
208V, 4
KW,
33.3AMPS
3 YEARS COMMERCIAL TANK WARRANTY.
NEUTRALIZATION KIT, PIPE IW TO MOP
RECEPTOR SEE DETAIL 2/P3.0. SET AT 140°F.
MASS APPROVAL CODE P3-0818-56
WC-1 &
WC-3
NOTES:
1. REFER TO ARCHITECTURAL FLOOR PLANS AND INTERIOR ELEVATIONS FOR EXACT LOCATION AND MOUNTING HEIGHT OF EACH FIXTURE.
WC-2
SPECIALTY EQUIPMENT SCHEDULE
MINIMUM ROUGH IN CONNECTION SIZE
EQUIP
TAG
EQUIPMENT
QTY
CW
CWF
(FILTERED)
03
COFFEE MAKER
2
X
04
ESPRESSO MAKER
1
X
05
RESTAURANT COFFEE MAKER
2
08
COMMERCIAL DISHWASHER
3
10
ICE MAKER, UNDERCOUNTER
1
15
GLASS WASHER
1
20
WASHER
1
HW
HW
(125°F) (140°F)
S OR W
(DIRECT)
IW
VENT
GAS
COMMENTS
SHOWER: AKER BY MAAX MODEL 141402-L ACRYLIC ALCOVE
ONE-PIECE TRANSFER SHOWER W/CENTER DRAIN, TEXTURED
BOTTOM, GRAB BARS, AND FOLD-UP L-SHAPED SEAT. COMES
COMPLETE WITH CHROME PRESSURE BALANCE MIXING VALVE
WITH HAND-HELD SHOWER, CHROME 24" SLIDE BAR AND 60"
FLEXIBLE HOSE. PROVIDE WEIGHTED CURTAIN ROD, SHOWER
CURTAIN, HEAVY DUTY S.S. OR CHROME BRASS ROLLER
SHOWER CURTAIN RINGS. PROVIDE VINYL COLLAPSIBLE DAM
AND BRASS SHOWER DRAIN. COMPONENTS SHALL BE METAL
AND NONMETALLIC CONSTRUCTION, PLATED IN STANDARD
POLISHED CHROME FINISH.
SHOWER: AKER BY MAAX MODEL 141402-L ACRYLIC ALCOVE
ONE-PIECE TRANSFER SHOWER W/CENTER DRAIN, TEXTURED
BOTTOM, GRAB BARS, AND FOLD-UP L-SHAPED SEAT. COMES
COMPLETE WITH CHROME PRESSURE BALANCE MIXING VALVE
WITH HAND-HELD SHOWER, CHROME 24" SLIDE BAR AND 60"
FLEXIBLE HOSE. PROVIDE WEIGHTED CURTAIN ROD, SHOWER
CURTAIN, HEAVY DUTY S.S. OR CHROME BRASS ROLLER
SHOWER CURTAIN RINGS. PROVIDE VINYL COLLAPSIBLE DAM
AND BRASS SHOWER DRAIN. COMPONENTS SHALL BE METAL
AND NONMETALLIC CONSTRUCTION, PLATED IN STANDARD
POLISHED CHROME FINISH.
HAND WASH SINK: ELKAY LUSTERTONE MODEL LRADQ172055
CLASSIC STAINLESS STEEL 17"x20", SINGLE BOWL DROP-IN SINK.
SINK IS MANUFACTURED FROM 18 GAUGE 304 STAINLESS STEEL
WITH A LUSTROUS SATIN FINISH, REAR CENTER DRAIN
PLACEMENT, AND BOTTOM ONLY PADS. SINGLE HOLE
CENTERED. ELKAY LK500LGN05T4 SINGLE HOLE DECK MOUNT
GOOSENECK SPOUT KITCHEN FAUCET WITH 4" WRISTBLADE
HANDLES. FAUCET HAS A FLOW RATE OF 1.5 GPM, AND IS MADE
OF SOLID BRASS, WITH A CERAMIC DISC VALVE. FAUCET
REQUIRES 1 FAUCET HOLE. PROVIDE LK99 STRAINER. 1/2" x
3/8"CP BRASS STOPS AND SUPPLIES TO SUIT (2). 1-1/2" x 2" CP
BRASS P-TRAP TO SUIT. TRUEBRO HANDICAPPED INSULATION
KIT.
KITCHEN SINK: ELKAY LUSTERTONE MODEL LRADQ332265PD
CLASSIC STAINLESS STEEL 33"x22", DOUBLE BOWL DROP-IN SINK.
SINK IS MANUFACTURED FROM 18 GAUGE 304 STAINLESS STEEL
WITH A LUSTROUS SATIN FINISH, REAR CENTER DRAIN
PLACEMENT, AND BOTTOM ONLY PADS. SINGLE HOLE
CENTERED.
ELKAY LKGT1041CR SINGLE HOLE DECK MOUNT GOURMET
KITCHEN FAUCET WITH PULL-OUT SPRAY AND LEVER HANDLE.
FAUCET HAS A FLOW RATE OF 1.75 GPM, AND IS MADE OF SOLID
BRASS, WITH A CERAMIC DISC VALVE. FAUCET REQUIRES 1
FAUCET HOLE. PROVIDE LK99 STRAINER. 1/2" x 3/8"CP BRASS
STOPS AND SUPPLIES TO SUIT (2). 1-1/2" x 2" CP BRASS P-TRAP TO
SUIT.
TRUEBRO
HANDICAPPED
URINAL:
AMERICAN
STANDARD INSULATION
PINTBROOK KIT.
MODEL 6002.001,
WALL MT, WHITE, VITREOUS CHINA TOP SPUD URINAL (.125-0.5
GPF), WITH AMERICAN STANDARD 6063.051.002 HARD WIRED
SENSOR OPERATED FLUSH VALVE (0.5 GPF). PROVIDE JAY R
SMITH 0635 SERIES STRUCTURAL STEEL URINAL CARRIER
COMPLETE WITH ALL REQUIRED HARDWARE TO SUIT.
WATER CLOSET: AMERICAN STANDARD AFWALL MODEL 2631.101
WALL-MOUNT, BACK SPUD, ELONGATED, WHITE, VITREOUS
CHINA, 1.28 GPF, WITH 5905.100 ELONGATED HEAVY DUTY OPEN
FRONT SEAT LESS COVER. WITH SLOAN ROYAL 152
ESS-1.28.TMO-2-10-3/4-LDIM-HW IN WALL SENSOR FLUSHOMETER
WITH ACCESS PANEL AND TRUE MECHANICAL OVERRIDE, HARD
WIRED AND JAY R. SMITH FIXTURE CARRIER COMPLETE WITH ALL
REQUIRED HARDWARE TO SUIT MOUNTING ORIENTATION.
WATER CLOSET: AMERICAN STANDARD AFWALL MODEL 2631.101
WALL-MOUNT, BACK SPUD, ELONGATED, WHITE, VITREOUS
CHINA, 1.28 GPF, WITH 5905.100 ELONGATED HEAVY DUTY OPEN
FRONT SEAT LESS COVER. WITH SLOAN ROYAL 152
ESS-1.28.TMO-2-10-3/4-LDIM-HW IN WALL SENSOR FLUSHOMETER
WITH ACCESS PANEL AND TRUE MECHANICAL OVERRIDE, HARD
WIRED AND JAY R. SMITH FIXTURE CARRIER COMPLETE WITH ALL
REQUIRED HARDWARE TO SUIT MOUNTING ORIENTATION.
S OR W
COMMENTS
MOUNT LAV IN ACCORDANCE
WITH ADA FOR HANDICAP
REQUIREMENTS. PROVIDE
TMV-1 BELOW, SET TO 105 ° F.
1/ "
2
1/ "
2
11/2" TO 2"
11/2"
MOUNT LAV IN ACCORDANCE
WITH ADA FOR HANDICAP
REQUIREMENTS.
1/ "
2
1/ "
2
TO 3/8"
1/ "
2
1/ "
2
11/2" TO 2"
TO 3/8"
-
WITH SHUTOFF, STRAINER,
AND IDW HOSE
1/2"
1/2" DRAIN
X
IDW TO FD
PROVIDE WASHER BOX
NOTES:
1. ALL EQUIPMENT, FIXTURES AND FAUCETS SHOWN ON THIS SCHEDULE SHALL BE FURNISHED BY THE FOOD SERVICE CONTRACTOR, UNLESS NOTED OTHERWISE.
MAJOR EQUIPMENT SHALL BE SET IN PLACE BY THE FOOD SERVICE CONTRACTOR. THE PLUMBING CONTRACTOR SHALL INSTALL ALL PLUMBING RELATED FAUCETS AND
HARDWARE. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL REQUIRED TRAPS, SUPPLIES, STOPS, INDIRECT WASTE PIPING AND NECESSARY HARDWARE
AS REQUIRED FOR A COMPLETE INSTALLATION.
2. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL THE DOMESTIC WATER HEATER 104V (REFER TO DWH-1 ON PLUMBING EQUIPMENT SCHEDULE).
1
P-1
FLOOR DRAIN
RD
ROOF DRAIN
-
WH
1/ "
2
3"
BRITISH THERMAL UNIT
BTUH
BRITISH THERMAL UNITS PER HOUR
CO
CLEANOUT
CFH
CUBIC FEET PER HOUR
CFM
CUBIC FEET PER MINUTE
FCO
FLOOR CLEANOUT
CLG
CEILING
GCO
GRADE CLEANOUT
CP
CHROME PLATED
W&T
WASTE AND TRAP (P-TRAP)
CO
CLEANOUT
CTE
CONNECT TO EXISTING
CW
COLD WATER
HB
WH
1/ "
2
1/ "
2
2"
WHA/SA
CTE
ETBR
HOSE BIB
DIA
DIAMETER
DWG
DRAWING
WALL HYDRANT
WATER HAMMER ARRESTOR/SHOCK ABSORBER
CONNECT TO EXISTING
EXISTING TO BE REMOVED
FLOW IN DIRECTION OF ARROW
MOUNT SHR AND ALL
COMPONENTS IN ACCORDANCE
WITH ADA FOR HANDICAP
REQUIREMENTS.
1/ "
2
1/ "
2
2"
S=.01
S=.02
PITCH IN FEET PER FOOT (1% OR
1/ "
8
PER FOOT)
PITCH IN FEET PER FOOT (2% OR
1/ "
4
PER FOOT)
STRAINER
11/2"
PIPE SLEEVE
EXPANSION JOINT
MOUNT SINK AND ALL
COMPONENTS IN ACCORDANCE
WITH ADA FOR HANDICAP
REQUIREMENTS.
NUM
KEY NOTE DESIGNATION
HWRP
1/ "
2
1/ "
2
2"
11/2"
HOT WATER RECIRC PUMP
1/ "
2
1/ "
2
2"
11/2"
TMV
S
3/ "
4
-
2"
11/2"
MOUNT UR IN ACCORDANCE
WITH ADA FOR HANDICAP
REQUIREMENTS.
RPBP
TPV
1"
-
4"
2"
T
MOUNT WC IN ACCORDANCE
WITH ADA FOR HANDICAP
REQUIREMENTS.
1"
-
4"
ELEVATION
ETR
EXISTING TO REMAIN
EX
EXISTING
FFE
FINISH FLOOR ELEVATION
FLR
FLOOR
FCO
FLOOR CLEANOUT
FP
FIRE PROTECTION
FPM
FEET PER MINUTE
FW
FILTERED WATER
FT
FOOT
GPF
GALLON(S) PER FLUSH
GPM
GALLON(S) PER MINUTE
GC
GENERAL CONTRACTOR
GI
GREASE INTERCEPTOR
HC
HANDICAPPED
HP
HORSE POWER
HW
HOT WATER
HWR
HOT WATER RETURN
HZ
HERTZ
INV
INVERT
INDIRECT WASTE
KW
KILOWATTS
SHUT-OFF VALVE (BALL VALVE)
LPC
LIMIT OF PLUMBING CONTRACTOR
MBH
1,000 BTU'S PER HOUR
MECH
MECHANICAL
NC
NORMALLY CLOSED
CHECK VALVE
NO
NORMALLY OPEN
GAS SHUT-OFF VALVE
NTS
NOT TO SCALE
NIC
NOT IN CONTRACT
OED
OPEN END DRAIN
BALANCING VALVE
PC
PLUMBING CONTRACTOR
BACK WATER VALVE
PH
PHASE
PLBG
PLUMBING
PSI
THERMOSTATIC MIXING VALVE
SOLENOID VALVE
OS&Y
DOWN
EL/ELEV.
IW
GATE VALVE
MOUNT SINK AND ALL
COMPONENTS IN ACCORDANCE
WITH ADA FOR HANDICAP
REQUIREMENTS.
DN
BOW VENT
TRAP PRIMER
OUTSIDE SCREW AND YOKE VALVE
RPBP
REDUCED PRESSURE BACKFLOW PREVENTER
RPM
POUNDS PER SQUARE INCH
REDUCED PRESSURE BACKFLOW
PREVENTER
REVOLUTIONS PER MINUTE
SA
SHOCK ABSORBER
TEMPERATURE PRESSURE-RELIEF VALVE
SS
SOIL STACK
VACUUM RELIEF VALVE
SPEC
SPECIFICATION
AQUASTAT
TP
TRAP PRIMER (CW CONNECTION)
TYP
TYPICAL
V
VENT
VACUUM BREAKER
TEMPERATURE GAUGE
PRV
PRESSURE REDUCING VALVE
VB
PG
PRESSURE GAUGE
VS
VENT STACK
VTR
VENT THROUGH ROOF
GLOBE VALVE
2"
BALANCING STATION
VIV
VALVE IN VERTICAL
W
WASTE
WC
WATER COLUMN
WV
WET VENT
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
hvac
CSI
Engineering
fire protection
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
MILLION AIR- PEASE
EXETER ROAD
PORTSMOUTH, NH 03801
Sullivan Construction, LLC.
PIPING LEGEND
DETAIL DESIGNATION NUMBER
DETAIL DESIGNATION DRAWING
AG
ABOVE GROUND PIPING (SINGLE LINE)
BG
BELOW GROUND PIPING (DOUBLE LINE)
CW
COLD WATER PIPING
HW
HOT WATER PIPING
HOT WATER RECIRC PIPING (RETURN)
TW
TW
TEMPERED HOT WATER SUPPLY
TW
TWR
TEMPERED HOT WATER RETURN
HOT WATER SUPPLY (140°)
140°F
FIXTURE / EQUIPMENT TAG
HOT WATER RECIRCULATING (140°)
140°F
S,W
V
12/1/2022 2:06:48 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
CONTINUATION
UNION
11/2"
(XX)
XX-#
COLD WATER FILTERED
CONT
TEE LOOKING UP
POWERED EQUIPMENT DESIGNATION
POWERED EQUIPMENT DATA
XX
CWF
CAP ON END OF PIPE
2"
MOUNT SHR AND ALL
COMPONENTS IN ACCORDANCE
WITH ADA FOR HANDICAP
REQUIREMENTS.
BUILDING
BTU
TEE LOOKING DOWN
1/ "
2
BELOW FINISHED FLOOR
BLDG
AREA DRAIN
RISER DOWN (ELBOW)
HB
BFF
AD
RISER UP (ELBOW)
PROVIDE AT EACH LAV-1 AND
LAV-2. SET FOR 110° F HOT
WATER.
ABOVE FINISH FLOOR
TRENCH DRAIN
HWR
XX
AFF
TD
11/2"
DESIGNATION INDICATOR
1/2"
FD
V
NOTES:
1. ROUGH IN SIZES NOTED ARE THE MINIMUM SIZES AS REQUIRED AT THE FIXTURE CONNECTION. PIPE SIZES MAY BE LARGER DEPENDING ON DISTANCE
FROM MAINS, PIPING PITCH, VENTING RULES, OTHER CONDITIONS AND LAYOUT, ETC. REFER TO THE FLOOR PLANS FOR SPECIFIC PIPE SIZING.
2. REFER TO ARCHITECTURAL FLOOR PLANS AND INTERIOR ELEVATIONS FOR EXACT LOCATION AND MOUNTING HEIGHT OF EACH FIXTURE.
3. ALL VITREOUS CHINA FIXTURES SHALL BE WHITE. ALL FAUCETS SHALL BE CHROME PLATED BRASS UNLESS NOTED OTHERWISE.
X
X
HW
ABBREVIATIONS
plumbing
FLOOR DRAIN : WATTS FD-100-B-7 CAST IRON FLOOR DRAIN WITH
HEAVY DUTY NICKEL BRONZE STRAINER AND TRAP PRIMER
CONNECTION
-
LAVATORY: KOHLER K-20000, CAXTON, RECTANGLE UNDER
MOUNT BATHROOM SINK, OVERFLOW DRAIN, VITREOUS CHINA,
1281904-7 UNDER MOUNT, COLOR WHITE, 15 11/16" x 20 1/4" x 7 5/16"
DEEP
. INSTALL IN RECOMMENDED ADA INSTALLATION. BRADLEY
S53-3500 VERGE FAUCET- LINE A SERIES, BRUSHED BACK
STAINLESS FINISH, TOUCH FREE DUAL SENSOR ACTIVATION,
BATTERY, CAST BRASS CONSTRUCTION, STRAIGHT GRID DRAIN
ASSEMBLY. MATCHING VERFE DECK MOUNTED SOAP DISPENSER
1/ "x3/ " CP BRASS STOPS AND SUPPLIES TO SUIT
6-3500, TOP FILL.
2
8
1/ " 1CP BRASS TAIL PIECE W/GRID DRAIN AND 1 1/ "x1 1/ " CP
(2).
4
2
4
BRASS P-TRAP TO SUIT. TRUEBRO HANDICAPPED INSULATION
KIT.
LAVATORY: AMERICAN STANDARD MODEL 0475.047 AQUALYN,
VITREOUS CHINA, DROP-IN COUNTERTOP OVAL LAVATORY.
AMERICAN STANDARD 7755.205 SELECTRONIC BATTERY
POWERED SENSOR OPERATED CHROME PLATED BRASS
LAV-2
FAUCET,
CENTER HOLE. 1/2"x3/8" CP BRASS STOPS AND SUPPLIES TO SUIT
(2). 1 1/4" CP BRASS TAIL PIECE W/GRID DRAIN AND 1 1/2"x11/4" CP
BRASS P-TRAP TO SUIT. TRUEBRO HANDICAPPED INSULATION KIT.
SH-1
TOTAL EQUIVALENT DESIGN LENGTH: 175'
DESIGN PRESSURE: LOW PRESSURE .5 PSI (14"
WC)
MINIMUM PRESSURE REQUIRED: 8" WC
MAXIMUM PRESSURE DROP: 0.50" WC
SPECIFIC GRAVITY: 0.60
TAG
SPECIFICATION
CW
DOMESTIC HOT WATER RE-CIRCULATING PUMP: TACO
006-BC7-IFC, BRONZE, 3250 RPM. 115V, 1/40 HP, 1 PH, 0.52 A
GENERAL LEGEND
MINIMUM ROUGH IN CONNECTION SIZE
electrical
PLUMBING EQUIPMENT SCHEDULE
SOIL OR WASTE PIPING
VENT ABOVE PIPING
RL
RW
RAIN WATER PIPING (STORM DRAINAGE)
ORL
ORL
OVERFLOW RAIN WATER PIPING (STORM)
IW
IW
INDIRECT WASTE PIPING
G
G
NATURAL GAS PIPING
GV
GV
Scale:
Date:
Project Number:
1" = 10'-0"
12.02.2022
2021-167
GAS VENT PIPING
REVISIONS
NO.
DESCRIPTION
DATE
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
SCHEDULE OF DRAWINGS
DWG#
COVID 19 SYSTEM QUESTIONS
GENERAL NOTE:
1. THE CONTRACTOR SHALL COORDINATE WITH OWNER, BUILDING OCCUPANTS AND CLIENTS MANAGERS FOR ALL REQUIRED COVID-19 SAFETY MEASURES TO BE EMPLOYED AT THE SITE. ALL PROTOCOLS SHALL BE IMPLEMENTED DURING CONSTRUCTION. ALL COVID-19
PROTOCOLS SHALL BE TAKEN INTO CONSIDERATION WHEN SUBMITTING A BID AND NO CHANGE ORDERS WILL BE ISSUED TO COVER SUCH COST, INCLUDING, BUT NOT LIMITED TO EFFECTS ON SCHEDULING OF WORK AND MANPOWER.
DRAWING TITLE
P0.01
LEGEND, NOTES & ABBREVIATIONS
P1.00a
UNDERSLAB PLAN - PART A
P1.00b
UNDERSLAB PLAN - PART B
P1.01a
GROUND LEVEL FLOOR PLAN - PART A
P1.01b
GROUND LEVEL FLOOR PLAN - PART B
P1.02a
SECOND FLOOR PLAN - PART A
P1.02b
SECOND FLOOR PLAN - PART B
P1.03a
ROOF PLAN - LOW ROOF
P1.03b
ROOF PLAN - HANGAR ROOF
P2.01
ENLARGED PLANS, NOTES & DETAILS
P2.02
ENLARGED PLANS
P3.01
DETAILS
P4.01
SPECIFICATIONS
LEGEND, NOTES
&
ABBREVIATIONS
P0.01
COPYRIGHT C 2022
GENERAL PLUMBING NOTES
1.
REFER TO DRAWING P0.01 FOR LEGENDS, ABBREVIATIONS AND
GENERAL NOTES.
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
F
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
G
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
G
2
3
4
5
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
6
H
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
H
@ 1/8"/FT
2.81
3.81
hvac
5' HIGH
WALLS
H.5
2"W UP
SEE SITE PLAN FOR
CONTINUATION
4"UP TO GCO
00
2"W BY G.C.
PORTE COCHÈRE
H.1
X
2"V UP
UP
2" CW
Engineering
fire protection
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
3" UP TO FCO
MILLION AIR- PEASE
1-1/2"V UP
6" W
1" CW
1" CW
UP
3"W&T UP
J.2
4" W
1"CW UP
2"CW UP
BY G.C.
2"V UP
EJ
3"W&T UP
J.3
3" W
4"W UP
2"V UP
3"W&T UP
Sullivan Construction, LLC.
J.4
4"W UP
K
4" W
4"W UP TO
VERTICAL
CARRIER
I.1
J.5
1-1/2"W UP
2" W
4" W
3"W&T UP
UP TO FD-1
EXETER ROAD
PORTSMOUTH, NH 03801
J.1
4" W
8"RL UP
UP TO FCO-1
J
UP TO FD
2"W UP
3" UP TO FCO
Y
2"W UP
2"W UP
2"V UP
3"W&T
3"W&T UP
1-1/2"V UP
(DISHWASHER)
EJ 4" UP TO FCO
4"W UP
3"W&T
UP
1"CW UP
3"W UP
3" W
2" W
3"W&T UP
3" W
4" UP
TO FCO
GIRT LINE
0
3"W&T UP
4"W UP
CSI
plumbing
electrical
H.5
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
3"W&T UP
1-1/2"W UP
4"UP TO FCO
2"V UP
3"W&T UP
Z
1.1
J.7
L
ENCLOSURE BY
ARCHITECT
12/1/2022 2:06:51 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
W
2"
I.2
Scale:
Date:
Project Number:
2"W UP
M
1/8" = 1'-0"
12.02.2022
2021-167
I.3
REVISIONS
NO.
K.1
K.9
1.9
2.8
3.8
5.
1
UNDERSLAB PLAN - PART A PLUMBING
1/8" = 1'-0"
DESCRIPTION
DATE
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
UNDERSLAB
PLAN - PART A
4.8
P1.00a
COPYRIGHT C 2022
GENERAL PLUMBING NOTES
1.
REFER TO DRAWING P0.01 FOR LEGENDS, ABBREVIATIONS AND
GENERAL NOTES.
8"RW AND 4"W
CONT. BY G.C.
1
3"V UP
A
2"V UP
UP TO FCO-2
UP TO FCO-2
4" W
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
B
4" W
OS-1
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
4"W&J
DRAIN OUTLET
BACK WATER
VALVE
TRENCH DRAINSEE GROUND
LEVEL PART B
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
D
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
UP TO
FCO-2
E
CSI
Engineering
fire protection
plumbing
electrical
hvac
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
MILLION AIR- PEASE
F
EXETER ROAD
PORTSMOUTH, NH 03801
Sullivan Construction, LLC.
G
G
@ 1/8"/FT
2
3
4
5
6
H
H
2.81
5' HIGH
WALLS
H.5
H.5
Scale:
Date:
Project Number:
0
00
1/8" = 1'-0"
12.02.2022
2021-167
PORTE COCHÈRE
REVISIONS
H.1
UP
NO.
X
GIRT LINE
12/1/2022 2:06:52 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
3.81
UP
J.2
REFER TO UNDERSLAB
PART A PLAN FOR ALL
PLUMBING IN THIS AREA
DESCRIPTION
DATE
EJ
J
J.1
EJ
J.3
J.4
1.1
1
1.9
5.
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
UNDERSLAB
PLAN - PART B
UNDERSLAB PLAN - PART B PLUMBING
1/8" = 1'-0"
P1.00b
COPYRIGHT C 2022
GENERAL PLUMBING NOTES
1.
REFER TO DRAWING P0.01 FOR LEGENDS, ABBREVIATIONS AND
GENERAL NOTES.
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
F
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
G
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
G
HANGAR
150
2
3
4
5
6
H
H
2.81
3.81
1/2"CW DP
1/2"HW DP
WB-1
2"W&T UP
2"V UP
UP
124
125
123
2"W&T
2"W&T
6"ORL UP
X
STOR
UP
CO
122
CO
J.2
1"CW DN
1"CW DN
J.3
1/2"CW DP
BFP-2
SK-1
EWH
1
1/2"CW DP & 1/2"HW DP
AND RUN UNDER
COUNTER TO SK-1
JAN
121
FD-B
2"W UP
1-1/2"V DN
2"V UP
2"W&T UP
ELECTRICAL
?
?
CO
128
FD-B
WC-2
WC-1
2"V RISE
2"V UP
2"W&T UP
1-1/2" CW DROP
1-1/2" HW DROP
K
2"W&T UP
I.1
CAFE CART
133
FD-B
3"FCO
STORAGE
BAGS
120
118
135
116-S
EJ
CLOS
STAIR 2
134
ST-2
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
MILLION AIR- PEASE
J
FD-B
113
LAV-1
WOMEN
LAV-1
114
WC-1
FD-B
2"W&T UP
J.1
FD-B
BEVERAGE
1/2" HW DP
2"W DN & 2"V RISE
1/2" CW DP
FIRE PUMP
112
1/2"CW DP
4"W UP
WSB-1
WC-1
2"W&T UP
FD-B
UR-1
LAV-1
MEN
WC-2
115
4"W DN
LAV-1
(4) 1-1/2"W DN &
1-1/2" V RISE
FD-B
J.4
EXETER ROAD
PORTSMOUTH, NH 03801
FW
Sullivan Construction, LLC.
1/2" FW UP TO
EACH SUPPLY BOX
INSTALLED ABOVE
BACKSPLASH
F-1
2"W&T UP FILTER IN
CABINET
UR-1
117
4"FCO
Engineering
SK-1
1/2" HW
2"W&T
UP
CO
CORR
MAIL
2
P2.02
CSI
4"FCO
130
108
FCO-1
LINE
132
fire protection
EL-1
Y
SERVICE AREA
4"W UP
3"V UP
FD-B
ELEV
2"V DN
SK-2
131
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
4"W DN
2"V DN
119
CORR
4" W
OFFICE
FCO
MECH
MB-1
3"W DN
1/2" CW DROP
1/2" HW DROP
WEST ENTRY
2"VTR
2"V DN
2" V UP
129
TP
3/4"CW DP
2"W DN & 2"V RISE
1
P2.02
6"ORL @ 1/4"/FT
6" DOWNSPOUT
NOZZLE 24" AFG
EJ
FD-B
2"W UP
4" W
(2) 2"W&T UP
4"W UP
1 1/2"V DN
1" CW DN
2" CW DN
FD-B
BFP-1
127
electrical
CORRIDOR
LSM
TP
H.1
2"W
UP
LAUNDRY
TP
FLIGHT PLAN
4"GCO
TP
4" W
CSR
hvac
CO
TP
4"W UP
ST-1
GIRT LINE
PORTE COCHÈRE
2"W&T UP
plumbing
0
CO
4" W
4"W UP
4"W DN
2"W&T
STAIR 1
H.5
2"W&T UP
2"W&T UP
CO
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
2"W DN & 1 1/2"V RISE
TP
5' HIGH
WALLS
H.5
00
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
J.5
CONDIMENTS
103
4"W DN
2"V DN
4" W DN
Z
WEST LOBBY
1.1
101
J.7
EAST ENTRY
110
L
RECEPTION
102
I.2
2"W UP
2"W DN
EAST LOBBY
12/1/2022 2:06:56 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
SEATING
M
104
105
I.3
CONFERENCE
CONFERENCE
107
106
Scale:
Date:
Project Number:
1/8" = 1'-0"
12.02.2022
2021-167
SOUTH ENTRY
109
REVISIONS
NO.
DESCRIPTION
DATE
K.1
K.9
1.9
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
2.8
3.8
5.
GROUND LEVEL - PART A PLUMBING
1
1/8" = 1'-0"
4.8
GROUND LEVEL
FLOOR PLAN PART A
P1.01a
COPYRIGHT C 2022
GENERAL PLUMBING NOTES
1.
REFER TO DRAWING P0.01 FOR LEGENDS, ABBREVIATIONS AND
GENERAL NOTES.
1
NEW GAS METER
A
3" G UP
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
FCO-2
3" V UP
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
B
FCO-2
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
TD-1
D
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
FCO-2
E
CSI
Engineering
fire protection
plumbing
electrical
hvac
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
HANGAR
MILLION AIR- PEASE
150
F
EXETER ROAD
PORTSMOUTH, NH 03801
Sullivan Construction, LLC.
G
G
2
3
4
5
6
H
H
3.81
5' HIGH
WALLS
H.5
H.5
Scale:
Date:
Project Number:
1/8" = 1'-0"
12.02.2022
2021-167
REVISIONS
0
00
PORTE COCHÈRE
NO.
H.1
X
UP
J.2
REFER TO GROUND FLOOR
PART A PLAN FOR ALL
PLUMBING IN THIS AREA
J
J.1
J.3
J.4
1
DATE
EJ
EJ
1.1
DESCRIPTION
UP
GIRT LINE
12/1/2022 2:06:57 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
2.81
1.9
5.
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
GROUND LEVEL
FLOOR PLAN PART B
GROUND LEVEL - PART B PLUMBING
1/8" = 1'-0"
P1.01b
COPYRIGHT C 2022
GENERAL PLUMBING NOTES
1.
REFER TO DRAWING P0.01 FOR LEGENDS, ABBREVIATIONS AND
GENERAL NOTES.
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
F
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
G
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
HANGAR
150
2
OPEN TO BELOW
3
4
5
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
6
H
1
P2.01
2
P2.01
3
P2.01
hvac
FS-1
220
0
SH-1
READY
READY
SH-2
DN
217
00
222
LAV-2
CORR
fire protection
227
FD-A
CORR
WC-3
LAV-2
214
LAV-2
1 1/4" CW
3/4" HWR
READY
WC-3
DN
FD-A
SH-1
READY
221
J.2
1" HW
EXPANSION
JOINT
GUTTER AND
DOWNSPOUT
(2) 3"CPVC
EJ & DN
UP
MECH.
215
SH-2
READY
FD-A
211
6"RL DN TO 8"RL DN
Y
STORAGE WC-3
LAV-2
213
(2) 3"CPVC
UP & DN
ELEV
READY
(2") FD-A
FD-A
1 1/4"G UP
TO RTU
LAV-2
WC-3
LAV-2
WC-3
Sullivan Construction, LLC.
J.4
LOUNGE
216
3/4" HW
FD-A
READY
EL-1
EXETER ROAD
PORTSMOUTH, NH 03801
J.1
1/2" HW DP
2" W DN & 2" V RISE
1/2" CW DP
EJ
SH-1
208
J
ST-2
SH-2
228
EJ
1" CW
3/4" HW
LAV-2
2" V DN SIM.
STAIR 2
READY
SH-2
WC-3
2"G DN
SK-2
FD-A
225
6"ORL DN
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
MILLION AIR- PEASE
WC-3
LAV-2
1 1/2" CW
3/4" HWR
FD-A
ELEC
1" HW
WC-3
LAV-2
WC-3
LAV-2
218
J.3
Engineering
212
ST-1
X
CSI
230
READY SH-1
224
FD-A
WC-3
STAIR 1
COMMON AREA
HSK
FD-A
H.1
electrical
1 1/4" G
HANGAR BALCONY
plumbing
H.5
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
J.5
READY
210
209
FS-1
SH-1
2"V DN
ALIGN
Z
SH-2
3/4" HWR
3/4" CW
OPEN TO
BELOW
OPEN TO BELOW
ALIGN
1/2" HW
4
P2.01
1.1
5
P2.01
J.7
L
12/1/2022 2:07:04 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
I.2
1/2" CW DP
2" W DN & 2" V RISE
1/2" HW DP
M
SK-1
SEATING
I.3
Scale:
Date:
Project Number:
1/8" = 1'-0"
12.02.2022
2021-167
204
REVISIONS
STORAGE
LOBBY STAIR
203
ST-3
NO.
DESCRIPTION
DATE
DECK
205
1/2" CW DP
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
K.1
1.9
K.9
2.8
3.8
4.8
1
5.
SECOND FLOOR
PLAN - PART A
SECOND FLOOR - PART A PLUMBING
1/8" = 1'-0"
P1.02a
COPYRIGHT C 2022
GENERAL PLUMBING NOTES
1.
REFER TO DRAWING P0.01 FOR LEGENDS, ABBREVIATIONS AND
GENERAL NOTES.
1
3"G DN
A
3/4"G UP
TO GUH
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
3/4"G UP
TO GUH
3/4" G
1 1/4" G
B
3" G
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
D
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
3" G
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
E
CSI
Engineering
fire protection
plumbing
electrical
hvac
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
MILLION AIR- PEASE
F
HANGAR
150
EXETER ROAD
PORTSMOUTH, NH 03801
Sullivan Construction, LLC.
3" G
G
2
3
4
5
6
3/4"G UP
TO GUH
H
3/4"G UP
TO GUH
1 1/4" G
2" G
12/1/2022 2:07:05 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
OPEN TO BELOW
H.5
Scale:
Date:
Project Number:
DN
1/8" = 1'-0"
12.02.2022
2021-167
REVISIONS
00
NO.
DESCRIPTION
DATE
H.1
SIM.
X
REFER TO SECOND FLOOR
PART A PLAN FOR ALL
PLUMBING IN THIS AREA
DN
J
J.2
J.1
EJ
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
EJ
GUTTER AND
DOWNSPOUT
EJ
1.1
1
1.9
5.
SECOND FLOOR
PLAN - PART B
SECOND FLOOR - PART B PLUMBING
1/8" = 1'-0"
P1.02b
COPYRIGHT C 2022
GENERAL PLUMBING NOTES
1.
3
4
5
REFER TO DRAWING P0.01 FOR LEGENDS, ABBREVIATIONS AND
GENERAL NOTES.
6
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
F
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
G
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
H
hvac
electrical
CSI
Engineering
fire protection
0
plumbing
H.5
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
00
MILLION AIR- PEASE
X
5.
EXETER ROAD
PORTSMOUTH, NH 03801
J
J.1
RD-1
Y
2
6" REG. AND
OVERFLOW RD
Sullivan Construction, LLC.
J.4
H.1
J.5
K
J.2
I.1
I.2
Z
2.81
3.81
1.1
J.7
L
12/1/2022 2:07:06 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
I.3
Scale:
Date:
Project Number:
K.1
1/8" = 1'-0"
12.02.2022
2021-167
M
REVISIONS
NO.
J.3
DESCRIPTION
DATE
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
1.9
K.9
2.8
3.8
4.8
1
ROOF PLAN LOW ROOF
ROOF PLAN - LOW ROOF - PLUMBING
1/8" = 1'-0"
P1.03a
COPYRIGHT C 2022
GENERAL PLUMBING NOTES
1.
1
3
4
5
REFER TO DRAWING P0.01 FOR LEGENDS, ABBREVIATIONS AND
GENERAL NOTES.
6
A
4" VTR
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
B
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
D
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
E
CSI
Engineering
fire protection
plumbing
electrical
hvac
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
MILLION AIR- PEASE
F
EXETER ROAD
PORTSMOUTH, NH 03801
Sullivan Construction, LLC.
G
H
12/1/2022 2:07:06 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
H.5
Scale:
Date:
Project Number:
3" VTR
3" VTR
1/8" = 1'-0"
12.02.2022
2021-167
REVISIONS
3" VTR
NO.
DESCRIPTION
DATE
5.
J
J.1
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
J.2
1
1.1
2
H.1
1.9
2.81
3.81
ROOF PLAN HANGAR ROOF
ROOF PLAN - HANGAR ROOF - PLUMBING
1/8" = 1'-0"
P1.03b
COPYRIGHT C 2022
4
R BATHROOM
R BATHROOM
222A
SH-1
227A
1/2" CW DP
1/2" HW DP
1/2" HW DP
1/2" CW DP
SH-1
(3) 2" V DN
FS-1
READY
READY
1/2" CW DP
1/2" HW DP
READY
222
217
224
(2")
FD-A
1" CW
R BATHROOM
FD-A
LAV-2
LAV-2
WC-3
FD-A
(2")
1" HW
3/4" HWR
R BATHROOM
221
EXPANSION
JOINT (TYP 3)
ELEC
218
SH-1
1 1/2" CW
1" HW
3/4" HWR
225
J
J
SH-1
1/2" HW DP
1/2" CW DP
1.9
228A
1" CW
3/4" HW
FD-A
1" CW
(2")
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
SH-1
READY
228
R BATHROOM
2"CW DN
1 1/2"HW DN
3/4"HWR DN
221A
1/2" CW DP
1/2" HW DP
2.81
2
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
R BATHROOM
J
1/2" HW DP
1/2" CW DP
SECOND FLOOR - READY ROOMS 217 & 218 PLAN
1/4" = 1'-0"
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
WC-3
READY
READY
218A
2" V DN
1" CW DP
3" VTR
2" V DN
1" CW DP
2" V DN
LAV-2
LAV-2
1 1/2" CW
1" HW
3/4" HWR
1 1/4" CW
WC-3
(2) CW DP
(2) HW DP
2" W DN & 2" V RISE
1" CW DP
3" VTR
2" V DN
1" CW DP
2" V DN
1" CW
3/4" HW
3/4" HWR
(2")
3/4" HW
2" V DN
LAV-2
1" CW
3/4" HW
2" V DN
1" CW DP
3" VTR
2" V DN
1" CW DP
2" V DN
(2)1/2" CW DP
(2)1/2" HW DP
2" W DN & 2" V RISE
(2)1/2" HW DP
(2)1/2" CW DP
2" W DN & 2" V RISE
1" CW
1" CW
3/4" HW
LAV-2
1" CW
(2")
3/4" HW
1 1/2" CW
1" HW
3/4" HWR
WC-3
217A
1
SH-1
227
HSK
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
3.81
SECOND FLOOR - READY ROOMS 221 & 222 PLAN
1/4" = 1'-0"
3
SECOND FLOOR - READY ROOMS 227 & 228 PLAN
1/4" = 1'-0"
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
CSI
Engineering
4
fire protection
1/2" CW DP
1/2" HW DP
1/2" HW DP
1/2" CW DP
SPECIALTY EQUIPMENT SCHEDULE
EQUIP
TAG
J.1
J.1
(2")
211
208
1" CW
3/4" HW
1" CW
3/4" HW
LAV-2
WC-3
1" CW
3/4" HW
FS-1
R BATHROOM
HW
(140°F)
COFFEE MAKER
2
1/2"
04
ESPRESSO MAKER
1
1/2"
05
RESTAURANT COFFEE MAKER
2
1/2"
08
COMMERCIAL DISHWASHER
3
10
ICE MAKER, UNDERCOUNTER
1
15
GLASS WASHER
1
1/2"
1/2"
20
WASHER
1
3/4"
3/4"
2" V DN
2" V DN
COMMENTS
IW
EXETER ROAD
PORTSMOUTH, NH 03801
1"
1/2"
1/2"
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
3/4"
WITH SHUTOFF,
STRAINER, AND IDW HOSE
1/2"
1/2" DRAIN
1-1/4"
TO/FROM WSDU
Sullivan Construction, LLC.
IDW TO FD
NOTES:
1. ALL EQUIPMENT, FIXTURES AND FAUCETS SHOWN ON THIS SCHEDULE SHALL BE FURNISHED BY OTHERS, UNLESS NOTED
OTHERWISE. MAJOR EQUIPMENT SHALL BE SET IN PLACE BY THE GENERAL CONTRACTOR. THE PLUMBING CONTRACTOR SHALL
INSTALL ALL PLUMBING RELATED FAUCETS AND HARDWARE. THE PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL ALL
REQUIRED TRAPS, SUPPLIES, STOPS, INDIRECT WASTE PIPING AND NECESSARY HARDWARE AS REQUIRED FOR A COMPLETE
INSTALLATION.
WC-3
READY
209
210
CWF
(FILTERED)
03
LAV-2
SH-1
READY
CW
208A
WC-3
1" CW
3/4" HW
1" CW
QTY
R WC
1" CW DP
3" VTR
2" V DN
1" CW DP
3/4" HWR
1/2" HW
3/4" CW
FD-A
(2")
FD-A
(2")
LAV-2
(2)1/2" CW DP
(2)1/2" HW DP
2" W DN & 2" V RISE
3" V DN
LAV-2
SH-1
1" CW
3/4" HW
1/2" CW
WC-3
READY
1" CW
1" HW
3/4" HWR
FD-A
STORAGE
213
(2")
1/2" CW
211A
1/2" HW
R WC
READY
1/2" HW
1/2" HW
SH-1
EQUIPMENT
2" W DN
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
MILLION AIR- PEASE
MINIMUM ROUGH IN CONNECTION
SIZE
J
plumbing
electrical
hvac
R BATHROOM
(2") FD-A
209A
SH-1
2" W DN
1/2" HW DP
1/2" CW DP
210A
12/1/2022 2:07:13 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
1/2" CW DP
1/2" HW DP
2.81
4
SECOND FLOOR - READY ROOMS 210 & 211 PLAN
1/4" = 1'-0"
3.81
5
Scale:
Date:
Project Number:
SECOND FLOOR - READY ROOMS 208 & 209 PLAN
1/4" = 1'-0"
As indicated
12.02.2022
2021-167
REVISIONS
NO.
DESCRIPTION
DATE
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
ENLARGED
PLANS, NOTES &
DETAILS
P2.01
COPYRIGHT C 2022
0
00
0
00
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
X
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
X
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
5
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
6
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
Y
Y
H.5
CSI
Engineering
fire protection
plumbing
electrical
hvac
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
MILLION AIR- PEASE
EXETER ROAD
PORTSMOUTH, NH 03801
Z
Sullivan Construction, LLC.
Z
5.
J
12/1/2022 2:07:15 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
1
GROUND LEVEL - CAFE CART ENLARGED PLAN
1/4" = 1'-0"
2
5.
GROUND LEVEL - SERVICE AREA ENLARGED PLAN
1/4" = 1'-0"
Scale:
Date:
Project Number:
1/4" = 1'-0"
12.02.2022
2021-167
REVISIONS
NO.
DESCRIPTION
DATE
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
ENLARGED
PLANS
P2.02
COPYRIGHT C 2022
BFP-1 REDUCED PRESSURE BACKFLOW
PREVENTER WITH FULL SIZE DRAIN
LINE. TERMINATE AT FLOOR DRAIN
WITH CODE REQUIRED AIR-GAP
PRESSURE GAUGE
3"CW TO SYSTEM
INSULATION
SHIELD SCHEDULE
FULL PORT BALL VALVE
IF STREET PRESSURE
EXCEEDS 80 PSI
PROVIDE PRV, SET FOR
70 PSI
TOP CLEARANCE
FOR TESTING
PIPE SIZE
DIM. A
GA. OF STEEL
UP TO 4"
12"
18
5" & 6"
18"
16
ABOVE 6"
24"
14
THREADED HANGER ROD
12"
INTEGRAL BALL VALVES
(TYPICAL)
ADJUSTABLE HANGER W/ ROLLER
(FOR 4" TO 6" PIPE)
HEAVY DUTY CLEVIS HANGER
(FOR ½" UP TO & INCLUDING 3" PIPE)
TRAPEZE PIPE HANGER
THREADED HANGER ROD
L
THREADED HANGER ROD
LOCKING NUT
AIR GAP FITTING
PIPE CLAMPS WITH
ELASTOMER OR NYLON
INSULATOR (TYP)
SUPPORT NUT
3/4" IW DRAIN LINE
PROVIDE WATER METER
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
3"
STRAINER
INSULATION
3/4"DV
18-24"
36" TO 48"
ABOVE FLOOR
3" GATE
VALVE
C
L
C
L
PIPE
°
135
GALVANIZED INSULATION
SHIELD 12" LONG.
FLOOR DRAIN
1/2 OF A
1/2 OF A
INSULATION SHIELD
SEE SCHEDULE
A
TIE BACK RODS TO FINISH
FLOOR
WATER SERVICE
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
PIPE COVERING
PROTECTION
16 GA. SADDLE
PROVIDE HEAT TRACING CABLE
WHERE INDICATED. ONE STRIP
FOR PIPES 6" AND SMALLER. TWO
STRIPS FOR PIPES 8" AND LARGER
PIPE
UN-INSULATED PIPING
(TYP)
METAL CHANNEL STRUT
RIGID INSULATION AT SHIELD
INSULATED PIPING WITH PIPE
CLAMP. PROVIDE WITH
INSULATION SHIELD.
NOTES:
PIPE HANGER/SHIELD DETAIL
NOTES:
1. FURNISH TO OWNER ONE TEST KIT AND SPARE PARTS KIT.
2. THIS CONTRACTOR SHALL ACT AS THE OWNERS AGENT IN SEEKING APPROVAL FROM ALL LOCAL AND STATE
AUTHORITIES. THIS CONTRACTOR SHALL SUBMIT ALL PLANS,SPECS. AND APPLICATIONS REQUIRED
FOR APPROVAL AND PAY ALL FEES.
3. SEE FLOOR PLANS FOR SIZES
4. TEST AND CERTIFY EACH INSTALLATION.
2
1.
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
SEE SPECIFICATION FOR HANGER SIZES.
1 PIPE HANGER DETAILS
WATER SERVICE DETAIL
NTS
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
SHUTOFF VALVE
1/2"
1/ "
2
WALL
STANDARD WEIGHT
STEEL PIPE SLEEVE
CW
CW
FAUCET
SINK
DISHWASHER DISCHARGE
1/2" COPPER PIPING FROM PIPING IN CEILING
TRAP PRIMER W/
VACUUM BREAKER
CW SUPPLY
ABOVE CEILING
OR UNDER
FIXTURE
COUNTER
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
COUNTER TOP
STOP VALVE
INSTANTANEOUS ELECTRIC
WATER HEATER
(EWH-2)
STOP VALVE
JUNCTION BOX BY
ELECTRICAL CONTRACTOR
1/ "CW
2
PROVIDE FLEXIBLE COPPER TUBING AS REQ'D.
CW
COLD WATER SUPPLY
1/ "HW
2
1/ "
2
FLOOR DRAIN TRAP
PRIMER DISTRIBUTION
UNIT (MOUNT ON WALL)
ICE MAKER CONNECTION
SIOUX CHIEF MODEL #696 SERIES
CW TO FLOOR DRAINS
W/TRAP PRIMER
CONNECTIONS, SEE
DRAWINGS FOR NUMBER
CONNECT TO REFRIGERATOR
ICE MAKER OR COFFEE MAKER
1/ "
2
THREE WAY ANGLE
STOP VALVE
BALL VALVE
SUPPLY
UNION
1/ "HW SUPPLY
2
TO DISHWASHER
1/ "
2
CARRIER PIPE
(SIZE VARIES)
SUPPLY
DISHWASHER
(BY OTHERS)
FINISH FLOOR
SEAL ASSEMBLY (SEE
NOTE BELOW)
NOTES:
FINISHED FLOOR
8 POINT OF USE MIXING VALVE DETAIL
NTS
7 INSTANTANEOUS ELECTRIC WATER HEATER
NTS
6 WATER SUPPLY BOX W/ MINI ARRESTOR DETAIL
NTS
5 TRAP PRIMER DETAIL
4 DISHWASHER CONNECTION UNDER COUNTER
NTS
Engineering
fire protection
SEAL ASSEMBLY SHALL BE MODULAR MECHANICAL TYPE
CONSISTING OF INTERLOCKING RUBBER LINKS SHAPED TO
CONTINUOUSLY FILL IN THE ANNULAR SPACE BETWEEN PIPE
& WALL OPENING PRESSURE PLATES SHALL BE DELRIN
PLASTIC BOLTS & NUTS SHALL BE 18.8 STAINLESS STEEL
SEALING ELEMENT SHALL BE EPDM RUBBER
1/4"
CSI
3 WATERTIGHT SLEEVE DETAIL
NTS
plumbing
HOT WATER SUPPLY (140°F)
POINT OF USE MIXING VALVE TMV-1
(BEHIND P-TRAP)
hvac
electrical
HOT WATER SUPPLY (110°F
FOR LAVS, 130°F FOR SINKS)
CW
HW
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
MILLION AIR- PEASE
EXETER ROAD
PORTSMOUTH, NH 03801
Sullivan Construction, LLC.
NC
AQUASTAT W/ PIPEWELL
3/ "
4
USE A REVERSE
RETURN
2"
INTERMATIC INC. MODEL
T171 24 HR. DIAL TIME
CLOCK WITH SKIPPER
FEATURE.
UNION
2"
2"
REDUCER (IF REQUIRED)
HVAC UNIT
BY HVAC CONTRACTOR
RP
1 1/2"
T
1 1/2"
VERTICAL TEE
GAS COCK(TYPICAL)
T
1
T & P RELIEF
VALVE (TYP)
FULL SIZE DISCHARGE TO
ADJACENT MOP RECEPTOR
WH-1
WH-1
REGULATOR
3" MIN. SEDIMENT LEG
XT-1
SEISMIC EXPANSION JOINT
PROVIDE PIPE SUPPORT
4"CONCRETE PAD
BY G.C.
NOTES:
FINISHED FLOOR
12/1/2022 2:07:15 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
1.
10 DOMESTIC WATER HEATING DIAGRAM
WATER TIGHT SLEEVE
NTS
PAINT EXTERIOR GAS PIPING WITH GRAY RUSTOLIUM PAINT
9 OUTDOOR HVAC GAS EQUIPMENT CONNECTION DETAIL
Scale:
Date:
Project Number:
1" = 10'-0"
12.02.2022
2021-167
NTS
REVISIONS
NO.
DESCRIPTION
DATE
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
DETAILS
P3.01
COPYRIGHT C 2022
A. GENERAL CONDITIONS
2.
12/1/2022 2:07:15 PM C:\Users\mbrake\Documents\2021-167 Million Air at Pease_Plumbing_mbrake.rvt
4.
5.
SCOPE OF WORK:
2.1. WITHOUT LIMITING THE GENERALITY THEREOF, PROVIDE ALL LABOR,
MATERIAL AND EQUIPMENT AS REQUIRED TO FURNISH AND INSTALL
COMPLETE PLUMBING AND RELATED SYSTEMS AS FOLLOWS:
2.1.1. POTABLE DOMESTIC COLD WATER, HOT WATER AND HOT WATER
RECIRC SYSTEMS AS REQUIRED TO CONNECT TO NEW PLUMBING
FIXTURES THROUGHOUT THE PROJECT.
2.1.2. POTABLE DOMESTIC TEMPERED WATER SUPPLY AND RETURN
SYSTEMS AS REQUIRED TO CONNECT TO NEW EMERGENCY
PLUMBING FIXTURES THROUGHOUT THE PROJECT.
2.1.3. NON-POTABLE COLD WATER, HOT WATER AND HOT WATER RECIRC
SYSTEMS AS REQUIRED TO CONNECT TO NEW LAB FIXTURES
THROUGHOUT THE PROJECT.
2.1.4. SANITARY WASTE AND VENT SYSTEM AS REQUIRED TO CONNECT TO
NEW PLUMBING FIXTURES THROUGHOUT THE PROJECT.
2.1.5. GARAGE WASTE AND VENT SYSTEM AS REQUIRED TO CONNECT TO
NEW GARAGE FLOOR DRAINS AND TRENCH DRAINS THROUGHOUT
THE PROJECT.
2.1.6. KITCHEN WASTE AND VENT SYSTEM AS REQUIRED TO CONNECT TO
NEW KITCHEN FIXTURES THROUGHOUT THE PROJECT.
2.1.7. LAB WASTE AND VENT SYSTEM AS REQUIRED TO CONNECT TO NEW
LAB FIXTURES THROUGHOUT THE PROJECT.
2.1.8. RAINWATER (STORM) DRAINAGE SYSTEMS AS REQUIRED TO
CONNECT TO NEW ROOF AND AREA DRAINS THROUGHOUT THE
PROJECT.
2.1.9. FUEL GAS (NATURAL) SYSTEM AS REQUIRED TO CONNECT TO NEW
FIXTURES AND EQUIPMENT THROUGHOUT THE PROJECT.
2.1.10. ALTERATIONS, ADDITIONS AND/OR REMOVAL OF EXISTING PLUMBING
SYSTEMS AND FIXTURES WITHIN THE RENOVATED AREAS AS SHOWN
IN ORDER TO CONFORM TO THE NEW SPACE REQUIREMENTS.
2.1.11. ALL PIPE, FITTINGS, VALVES, SLEEVES, HANGERS, SUPPORTS,
EXPANSION JOINTS AND RELATED COMPONENTS AS REQUIRED FOR
COMPLETE INSTALLATION OF EACH SYSTEM.
2.1.12. PIPE INSULATION FOR ALL COLD WATER, HOT WATER AND HOT
WATER RECIRC PIPING INCLUSIVE OF MAINS AND BRANCH PIPING AS
REQUIRED. PIPE INSULATION FOR ALL HORIZONTAL RAINWATER
PIPING INCLUSIVE OF ROOF DRAIN BODIES.
2.1.13. ACCESS PANELS FOR CONCEALED COMPONENTS AS REQUIRED
(FURNISHING ONLY). CORE DRILLING AS REQUIRED.
2.1.14. PLUMBING FIXTURES, FAUCETS, TRIM, SUPPLIES, STOPS, CARRIERS
AND ALL RELATED HARDWARE AS REQUIRED FOR A COMPLETE
INSTALLATION. PLUMBING EQUIPMENT INCLUSIVE OF ALL VALVES,
DRAINS, UNIONS, PRESSURE GAUGES, TEMPERATURE GAUGES AND
RELATED HARDWARE AS REQUIRED FOR A COMPLETE
INSTALLATION.
2.1.15. TESTING, ADJUSTING, BALANCING, FLUSHING AND STERILIZING. ALL
PERMITS AND FEES AS APPLICABLE. COMPLETE (1) ONE YEAR
GUARANTEE FOR ALL WORK.
RELATED WORK BY OTHER:
3.1. THE FOLLOWING RELATED WORK SHALL BE DONE BY OTHERS.
COORDINATE THE WORK OF THIS TRADE WITH THE RELATED WORK OF
EACH RESPECTIVE CONTRACTOR:
3.1.1. CUTTING AND PATCHING, TEMPORARY WATER, HEAT, FIRE
PROTECTION AND TOILET FACILITIES, TEMPORARY POWER AND
LIGHTING, EXCAVATION AND BACKFILL, CONCRETE AND MASONRY
SUPPORTS AND EQUIPMENT BASES, FLASHING AND CAULKING,
FINISH PAINTING, HEATING, VENTILATING AND AIR CONDITIONING,
FIRE PROTECTION, ELECTRICAL POWER AND WIRING, FURNISHING
OF TOILET ROOM ACCESSORIES, INSTALLATION OF ACCESS PANELS,
FOOD SERVICE EQUIPMENT, FOUNDATIONS AND TRENCHING.
INTENT OF THE DRAWINGS:
4.1. THE DRAWINGS ARE DIAGRAMMATIC IN NATURE AND DO NOT SHOW EVERY
PIPE, FITTING, ELBOW AND BEND. THIS CONTRACTOR SHALL PROVIDE ALL
NECESSARY PIPING, FITTINGS, VALVES, SLEEVES, HANGERS, SUPPORTS,
EXPANSION JOINTS AND COMPONENTS AS REQUIRED BY CODE FOR
COMPLETE SYSTEMS AS NOTED ABOVE AND IN ACCORDANCE WITH THE
NEW AND EXISTING ARCHITECTURAL, STRUCTURAL, MECHANICAL AND
ELECTRICAL ELEMENTS IN THE SPACE.
SUBMITTAL REQUIREMENTS:
5.1. UPON CONTRACT AWARD, SUBMIT A LIST OF THE PROPOSED
MANUFACTURER'S THAT IS INTENDED TO BE USED ON THIS PROJECT FOR
APPROVAL. THIS LIST MAY INCLUDE BOTH THE MANUFACTURER'S THAT ARE
SPECIFIED HERE AS WELL AS PROPOSED OR EQUAL MANUFACTURER'S.
ONCE THIS LIST IS APPROVED BY THE ENGINEER, NO SUBSTITUTIONS SHALL
BE ALLOWED. APPROVAL OF THE LIST OF MANUFACTURERS' DOES NOT
RELIEVE THIS CONTRACTOR OF THE RESPONSIBILITY OF MEETING ALL
REQUIREMENTS OF THE SPECIFICATIONS WITH REGARDS TO QUALITY AND
PERFORMANCE CRITERIA.
5.2. SUBMITTALS SHALL BE PROVIDED IMMEDIATELY AFTER CONTRACT AWARD
WITH AMPLE TIME FOR ENGINEER's REVIEW PRIOR TO INSTALLATION.
SUBMITTALS SHALL INCLUDE ALL QUALITY, PERFORMANCE AND
DIMENSIONAL INFORMATION AS REQUIRED FOR PROPER REVIEW.
SUBMITTALS SHALL BE CONCISE AND GENERALLY IN 8-1/2" x11" FORMAT OR
INCREMENTS THEREOF. PROVIDE (6) SETS OF COMPLETE SUBMITTALS OF
THE FOLLOWING ITEMS:
5.2.1. COORDINATION DRAWINGS OF ALL PLUMBING WORK.
5.2.2. PIPING AND FITTINGS FOR EACH PIPING SYSTEM AS SPECIFIED.
5.2.3. PLUMBING FIXTURES, FAUCETS AND TRIM AS LISTED IN THE
SCHEDULES.
5.2.4. PLUMBING EQUIPMENT AS LISTED IN THE SCHEDULES.
6.
7.
8.
2.
PROJECT CLOSE OUT REQUIREMENTS:
6.1. AT THE CLOSE OF THE PROJECT, BUT PRIOR TO FINAL PAYMENT OR
RELEASE OF RETAINAGE, PROVIDE THE FOLLOWING CLOSE OUT ITEMS FOR
REVIEW AND APPROVAL (NOTE THAT SOME OF THESE ITEMS REQUIRE ON
GOING MAINTENANCE):
6.1.1. OPERATING PARTS AND MAINTENANCE MANUALS FOR ALL PLUMBING
EQUIPMENT, FIXTURES, FAUCETS AND TRIM AS LISTED IN THE
SCHEDULES.
6.1.2. PROVIDE THE OWNER OR HIS REPRESENTATIVE A TRAINING SESSION
FOR INSTRUCTION IN THE USE OF ALL FIXTURES AND EQUIPMENT AS
LISTED IN THE SCHEDULES. THE APPROVED OPERATING PARTS AND
MAINTENANCE MANUALS SHALL BE MADE AVAILABLE AND USED
DURING THIS TRAINING SESSION.
6.1.3. MAINTAIN A COMPLETE SET OF RECORD DRAWINGS AT THE PROJECT
SITE. WORKING PROGRESS, AS INSTALLED, INCLUSIVE OF ALL
CHANGES TO THE CONTRACT, SHALL BE RECORDED ON A WEEKLY
BASIS ON THE RECORD DRAWINGS. AT THE END OF THE PROJECT,
THE RECORD DRAWINGS SHALL BE USED TO PREPARE THE AS-BUILT
DRAWINGS. THE RECORD DRAWINGS SHALL BE SUBMITTED WITH
THE AS-BUILT DRAWINGS FOR.
6.1.4. PROVIDE COMPLETE AS-BUILT DRAWINGS OF ALL WORK UNDER THIS
SECTION PRIOR TO FINAL INSPECTION AND SIGN OFF. AS-BUILTS
SHALL BE PROVIDED IN BOTH HARD COPY (1 SET) AND ELECTRONIC
FORMAT, AUTOCAD RELEASE 2015 OR HIGHER.
GUARANTEE:
7.1. GUARANTEE ALL MATERIALS, EQUIPMENT AND LABOR AGAINST ALL
DEFECTS FOR ONE YEAR FROM THE DATE OF SUBSTANTIAL COMPLETION.
PROVIDE ADDITIONAL GUARANTEES FROM MANUFACTURERS OF
EQUIPMENT AS APPLICABLE.
3.
DESIGN CRITERIA:
8.1. THE ENGINEER HAS PROVIDED A DESIGN (DRAWINGS, SPECIFICATIONS AND
CALCULATIONS) AND HAS SPECIFIED THE DESIGN CRITERIA TO BE USED BY
THE INSTALLING CONTRACTOR. THE INSTALLING CONTRACTOR SHALL
FURNISH AND INSTALL ALL SYSTEMS IN ACCORDANCE WITH THE DESIGN
CRITERIA INCLUSIVE OF ALL CHANGES OR MODIFICATIONS. THE ENGINEER
SHALL REVIEW AND APPROVED THE INSTALLING CONTRACTOR'S
SUBMITTALS AND SHOP DRAWINGS. THE ENGINEER SHALL PERFORM
PERIODIC INSPECTIONS AND CERTIFY THE SYSTEM INSTALLATION FOR CODE
COMPLIANCE UPON COMPLETION.
8.2. DOMESTIC COLD AND HOT WATER SIZING DESIGN CRITERIA SHALL BE BASED
ON HUNTER'S FIXTURE UNIT METHOD FOR LIGHT COMMERCIAL DESIGN
USING PRESSURE AND FRICTION LOSS CALCULATIONS FOR COPPER PIPE
AND FITTINGS NOT TO EXCEED 8 FPS.
8.3. SANITARY AND LAB WASTE AND VENT SIZING DESIGN CRITERIA SHALL BE
BASED ON THE MASSACHUSETTS STATE PLUMBING CODE FIXTURE UNIT
METHOD USING VARIOUS PITCH CALCULATION FOR VARIOUS PIPE SIZES AS
APPLICABLE.
8.4. FUEL GAS SYSTEMS DESIGN CRITERIA SHALL BE BASED ON NFPA 54
NATIONAL FUEL GAS CODE AND THE MASSACHUSETTS STATE FUEL GAS
CODE USING TOTAL CONNECTED BTUH OR CFH LOAD METHOD AND
FRICTION LOSS BASED ON SCHEDULE 40 STEEL PIPE WITH A TOTAL
PRESSURE DROP AS INDICATED OVER THE LONGEST RUN.
B. MATERIALS AND PRODUCTS
1.
PIPING:
1.1. WATER PIPING SHALL BE TYPE "L" COPPER TUBING WITH WROUGHT COPPER
OR CAST BRASS SOLDER FITTINGS AND LEAD-FREE SOLDER JOINTS
CONFORMING TO ASTM B-88, ANSI STANDARD B16.18, B16.18A AND B16.22
RESPECTIVELY OR VIEGA PRO-PRESS. FITTINGS AND JOINTS FOR PIPING
21/2" AND LARGER MAY BE VIEGA PRO-PRESS OR VICTAULIC COPPER
GROOVED FITTINGS WITH ROLL GROOVED COPPER TUBE JOINT AND
APPROVED NEOPRENE GASKETS AT THE CONTRACTOR'S OPTION. EXPOSED
WATER PIPING IN FINISHED AREAS SHALL BE CHROME PLATED.
1.2. SANITARY WASTE AND VENT BELOW GROUND SHALL BE HUB AND SPIGOT
CAST IRON PIPE WITH HUB AND SPIGOT CAST IRON FITTINGS CONFORMING
TO ASTM A-74 AND HS 74, MANUFACTURED IN ACCORDANCE WITH CAST
IRON SOIL PIPE INSTITUTE (CISPI) STANDARD 301 AND PAMPHLET 100.
JOINTS SHALL BE MADE WITH NEOPRENE PUSH JOINT GASKET AND
APPROVED LUBRICANT.
1.3. SANITARY WASTE AND VENT PIPING ABOVE GROUND SHALL BE HUBLESS
CAST IRON SERVICE WEIGHT PIPING WITH HUBLESS CAST IRON FITTINGS
CONFORMING TO ASTM A-888, MANUFACTURED IN ACCORDANCE WITH CAST
IRON SOIL PIPE INSTITUTE (CISPI) STANDARD 301 AND PAMPHLET 100.
JOINTS SHALL BE MADE WITH DOUBLE CLAMP, FOUR BAND RETAINER
SLEEVE AND NEOPRENE GASKET. WASTE AND VENT PIPING 2" AND
SMALLER MAY BE TYPE "M" COPPER TUBING CONFORMING TO ASTM B-88
WITH WROUGHT COPPER DRAINAGE PATTERN FITTINGS AND LEAD-FREE
SOLDER JOINT CONFORMING TO ANSI B16-23 (EXCEPT AT URINALS).
1.4. SANITARY WASTE AND VENT PIPING MAY BE SCHEDULE 40 PVC PIPING WITH
APPROVED PVC-DWV FITTINGS AS ALLOWED BY CODE. JOINTS SHALL BE
MADE WITH THE SOLVENT WELD METHOD IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS. REQUIRED FIRE RATED SEALING AND
EXPANSION JOINTS SHALL BE PROVIDED IN ACCORDANCE WITH CODE.
1.5. LAB WASTE AND VENT PIPING ABOVE GROUND SHALL BE POLYPROPYLENE
ACID RESISTANT PIPING WITH POLYPROPYLENE HEAT FUSION FITTINGS.
JOINTS SHALL BE MADE WITH HEAT FUSION SEAL METHOD IN ACCORDANCE
WITH THE MANUFACTURER'S INSTRUCTIONS.
1.6. GAS PIPING 2" AND SMALLER SHALL BE SCHEDULE 40 SEAMLESS STEEL PIPE
CONFORMING TO ASTM A120 WITH CAST IRON STANDARD WEIGHT OR BLACK
MALLEABLE THREADED FITTINGS AND JOINT COMPOUND OR SCHEDULE 40
BLACK STEEL PIPE WITH VIEGA MegaPress G FITTINGS WITH HNBR SEALING
ELEMENT AND CONFORM TO ANSI LC 4; 70 PSI. USE AND INSTALLATION OF
FITTINGS MUST BE PER MANUFACTURER'S STANDARDS.
1.7. GAS PIPING 21/2" AND LARGER SHALL BE SCHEDULE 40 BLACK STEEL PIPE
WITH BEVELED ENDS WITH STANDARD WEIGHT CARBON STEEL BEVELED
END FITTINGS JOINED BY BUT WELDING IN ACCORDANCE WITH
MASSACHUSETTS PLUMBING CODE SECTION 5.03. OR SCHEDULE 40 BLACK
STEEL PIPE WITH VIEGA MegaPress G FITTINGS WITH HNBR SEALING
ELEMENT AND CONFORM TO ANSI LC 4: 70 PSI. USE AND INSTALLATION OF
FITTINGS MUST BE PER MANUFACTURER'S STANDARDS.
1.8. PLUMBING CONTRACTOR SHALL FURNISH AND INSTALL GAS TRAIN VENTS
PER MASSACHUSETTS PLUMBING CODE SECTION 7.04 FOR ALL GAS FIRED
EQUIPMENT REQUIRING GAS TRAINS.
1.9. UNIONS FOR PIPING TWO INCHES AND SMALLER SHALL BE 125 PSI SWP
(STEAM WORKING PRESSURE) BRASS GROUND JOINT TYPE. FLANGES FOR
PIPING 21/2" AND LARGER SHALL BE 125 PSI SWP FLAT FACED CAST BRASS,
MALLEABLE STEEL OR CAST IRON FLANGES CONFORMING TO ANSI
STANDARDS. FLANGES SHALL HAVE RUBBER FULL FACED GASKETS.
1.10.
MATING OF FERROUS AND NONFERROUS PIPING SHALL BE SEPARATED
WITH FLANGES, EXTRA HEAVY BRASS FITTINGS OR DIELECTRIC FITTINGS
APPROVED FOR SUCH APPLICATION. FLANGES SHALL HAVE RUBBER
GASKETS (1/16 INCH MINIMUM THICKNESS) AND TEFLON LINERS INSTALLED
IN THE BOLT HOLES. PHYSICAL CONTACT BETWEEN FERROUS AND NONFERROUS FLANGES, INCLUDING THE BOLTS, NUTS AND WASHERS SHALL
NOT BE PERMITTED.
1.11.
JOINTS BETWEEN COPPER OR BRASS FITTINGS AND CAST IRON FITTINGS
SHALL BE MADE WITH MANHOFF FITTINGS SCREWED INTO THREADED PIPE
AND CAULKED INTO THE CAST IRON PIPE.
1.12.
WELDED JOINTS SHALL BE PERFORMED BY A CERTIFIED WELDER WITH
CERTIFICATION(S) FOR EACH SPECIFIC JOINT AND APPLICATION.
VALVES AND SPECIALTIES:
2.1. VALVES FOR ALL PIPING SYSTEMS (COLD WATER, HOT WATER, FUEL GAS,
ETC.) SHALL BE AS MANUFACTURED BY WATTS, APOLLO, JENKINS OR
APPROVED EQUAL. VALVES SHALL BE OF ONE MANUFACTURER FOR THE
ENTIRE PROJECT. WATTS VALVES ARE SPECIFIED HERE AS A GUIDE FOR
THE TYPE AND QUALITY TO BE PROVIDED UNDER THIS SPECIFICATION.
2.1.1. VALVES SHALL BE PROVIDED WITH BUNA-N, TFE OR EPDM SEATS
FOR THE SERVICE INTENDED. THE PRESSURE CLASSIFICATION FOR
ALL VALVES IS WATER OIL GAS (WOG) PRESSURE RATING OR STEAM
WORKING PRESSURE (SWP) RATING AS INDICATED. ALL VALVE
LEVER HANDLES SHALL BE COLOR CODED IN CONFORMANCE WITH
ANSI STANDARD AS-131.
2.1.2. SHUT-OFF VALVES FOR WATER SYSTEMS SHALL BE 150 PSI WOG
TWO PIECE BALL VALVE WITH VINYL GRIP LEVER HANDLE. SHUT-OFF
VALVES FOR FUEL GAS SYSTEMS SHALL BE EITHER 150 PSI WOG
TWO PIECE BALL VALVE WITH TEE HANDLE OR 150 PSI WOG
LUBRICATED PLUG TYPE VALVE. VALVES USED FOR BALANCING OR
CONTROLLING FLOW SHALL BE CIRCUIT SETTER TYPE BALL VALVE.
CHECK VALVES SHALL BE ALL BRONZE SWING CHECK TYPE, 125
CLASS SWP.
2.1.3. SERVICE SHUT-OFF VALVES FOR WATER PIPING: WATTS B-6000 OR
B-6001 SERIES ALL BRONZE BALL VALVE.
2.1.4. SERVICE SHUT-OFF VALVES FOR GAS PIPING: WATTS B-6000-UL
SERIES ALL BRONZE BALL VALVE WITH TEE HANDLE. SERVICE SHUTOFF VALVES FOR GAS PIPING 21/2" AND LARGER MAY BE WATTS
CAST LUBRICATED FLANGED PLUG VALVE IN LIEU OF THE ABOVE
SPECIFIED BALL VALVES AT THE CONTRACTOR'S OPTION.
2.1.5. BALANCING VALVES FOR WATER PIPING: WATTS CIRCUIT SETTER
TYPE ALL BRONZE BALL VALVE.
2.1.6. CHECK VALVES FOR WATER PIPING 2" AND SMALLER: WATTS CV OR
CVY SERIES SWEAT OR THREADED ALL BRONZE CHECK. CHECK
VALVES FOR WATER PIPING 21/2" AND LARGER: WATTS 411 SERIES
CHECK VALVE WITH FLANGED ENDS.
2.1.7. DRAIN VALVES FOR WATER PIPING: WATTS B-6000-CC OR B-6001-CC
3/4" ALL BRONZE HOSE END VALVE WITH CAP AND CHAIN.
2.1.8. SHOCK ARRESTERS SHALL BE MANUFACTURED IN ACCORDANCE
WITH PDI STANDARD WH201. SA-A (0 TO 11 WFU), SA-B (12 TO 32
WFU).
HANGERS AND ACCESSORIES:
3.1. ALL HORIZONTAL AND VERTICAL PIPING SHALL BE PROPERLY SUPPORTED
FROM THE BUILDING STRUCTURE BY STEEL RODS, INSERTS, BEAM CLAMPS,
FRICTION CLAMPS, HANGERS AND BRACKETS AS REQUIRED. CARPENTER
PATTERSON CATALOG NUMBERS SPECIFIED HEREIN AND ARE INTENDED AS
A GUIDE FOR THE TYPE AND QUALITY TO BE FURNISHED AND INSTALLED BY
THIS CONTRACTOR.
3.2. FRICTION CLAMPS SHALL BE EQUAL TO FIGURES 126 FOR CAST IRON OR
STEEL PIPE AND 126 CT FOR COPPER PIPE.
3.3. HANGERS FOR CAST IRON, STEEL AND ALL INSULATED PIPING (INCLUDING
INSULATED COPPER) SHALL BE CLEVIS TYPE EQUAL TO FIGURE 100.
HANGERS FOR UN-INSULATED COPPER AND BRASS PIPING SHALL BE
FACTORY APPLIED COPPER PLATED STEEL BAND HANGERS FIGURE 1ACT.
RODS AND NUTS SHALL ALSO BE FACTORY APPLIED COPPER PLATED.
3.4. EXTENSION TYPE SPLIT RING HANGERS WITH WALL PLATES FOR CAST IRON
AND STEEL PIPE SHALL BE EQUAL TO FIGURES 81, 85 AND 90. EXTENSION
TYPE SPLIT RING HANGERS WITH WALL PLATES FOR COPPER AND BRASS
PIPE SHALL BE EQUAL TO FIGURES 81-CT, 85-CT AND 90-CT.
3.5. WHERE THREE OR MORE PIPES ARE INSTALLED PARALLEL TO EACH OTHER,
FABRICATED GANG TYPE HANGERS MAY BE USED IN LIEU OF THE SPECIFIED
HANGERS. GANG HANGERS SHALL BE CONSTRUCTED OF UNISTRUT OR
OTHER APPROVED MATERIAL SPECIFICALLY DESIGNED FOR THIS
APPLICATION. PIPE SADDLE CLAMPS, PIPE SADDLE INSULATION
PROTECTORS OR ROLLER CLAMPS SHALL BE USED IN CONJUNCTION WITH
THE UNISTRUT AS APPLICABLE. CLAMPS SHALL BE CONSTRUCTED OF 18
GAUGE STEEL. GANG HANGERS SHALL BE SIZED TO PROVIDE FOR
INSULATION AND PIPE SADDLES FOR INSULATED PIPING WHEN APPLICABLE.
NEOPRENE PROTECTORS SHALL BE PROVIDED FOR UN-INSULATED COPPER
PIPING.
3.6. ALL HANGERS SHALL BE SUPPORTED FROM THE BUILDING STRUCTURE BY
STEEL THREADED RODS AS REQUIRED. THREADED RODS IN CONTACT WITH
COPPER OR BRASS PIPING SHALL BE COPPER OR PLASTIC COATED. STEEL
ROD SIZES SHALL BE AS FOLLOWS:
PIPE SIZE 1/2" TO 2" - 3/8" ROD
PIPE SIZE 21/2" TO 4" - 1/2" ROD
PIPE SIZE 5" TO 8" - 5/8" ROD
PIPE SIZE 10" & LARGER - 3/4" ROD
3.7. PIPE SADDLE INSULATION PROTECTORS SHALL BE PROVIDED FOR ALL
HORIZONTAL INSULATED PIPING. PIPE SADDLES SHALL BE CONSTRUCTED
OF GALVANIZED STEEL, FORMED TO A 180 DEGREE ARC, 12 INCHES LONG,
EQUAL TO FIGURE 265P, 18 GAUGE TYPE H.
3.8. HANGER RODS FOR INSTALLATIONS OTHER THAN THOSE SPECIFIED SHALL
BE SIZED IN ACCORDANCE WITH THE RECOMMENDED LOAD CAPACITIES OF
ASTM SPECIFICATION A-107.
3.9. INSERTS SHALL BE INDIVIDUAL OR STRIP TYPE OF PRESSED STEEL
CONSTRUCTION WITH ACCOMMODATION FOR REMOVABLE NUTS AND
THREADED RODS UP TO 3/4" DIAMETER, PERMITTING LATERAL ADJUSTMENT.
INDIVIDUAL INSERTS SHALL HAVE AN OPENING AT THE TOP TO ALLOW
REINFORCING RODS UP TO 1/2" DIAMETER TO BE PASSED THROUGH THE
INSERT BODY. STRIP INSERTS SHALL HAVE ATTACHED RODS WITH HOOKED
ENDS TO ALLOW FASTENING TO REINFORCING RODS.
3.10.
SEISMIC RESTRAINTS: PROVIDE SEISMIC RESTRAINTS IN ACCORDANCE
WITH THE MASSACHUSETTS STATE BUILDING CODE, CURRENT ADOPTED
EDITION.
4.
5.
6.
SLEEVES AND ESCUTCHEONS:
4.1. ALL PIPING PASSING THROUGH INTERIOR FLOORS, WALLS, OR PARTITIONS
SHALL BE PROVIDED WITH SLEEVES HAVING AN INTERNAL DIAMETER 1"
LARGER THAN THE OUTSIDE DIAMETER OF THE PIPE (OR INSULATION),
PROVIDING A MINIMUM 1/2" ANNULAR SPACE AROUND THE PIPE.
4.2. SLEEVES THROUGH INTERIOR NON-MASONRY WALLS OR PARTITIONS SHALL
BE 22 GAUGE GALVANIZED SHEET STEEL. SLEEVES THROUGH INTERIOR
MASONRY WALLS SHALL BE SCHEDULE 40 BLACK STEEL PIPE.
4.3. ALL PIPING PASSING THROUGH EXTERIOR WALLS SHALL BE PROVIDED WITH
SLEEVES HAVING AN INTERNAL DIAMETER 3" LARGER THAN THE OUTSIDE
DIAMETER OF THE PIPE, PROVIDING A MINIMUM 11/2" ANNULAR SPACE
AROUND THE PIPE.
4.4. SLEEVES THROUGH EXTERIOR WALLS SHALL EXTEND A MINIMUM OF 6"
BEYOND THE INTERIOR AND EXTERIOR SURFACE AND SHALL BE PROVIDED
WITH A NEOPRENE BOOT ON EACH SIDE OF THE SLEEVE ATTACHED TO THE
PIPE PROVIDING A WATERTIGHT FLEXIBLE SEAL.
4.5. ESCUTCHEONS SHALL BE PROVIDED WHERE PIPING PASSES THROUGH
WALLS OR FLOORS EXPOSED TO VIEW. ESCUTCHEONS SHALL BE CHROME
PLATED BRASS OR COPPER TYPE WITH A SET SCREW TO PROPERLY HOLD
ESCUTCHEON IN PLACE.
SMOKE AND FIRE STOPPING:
5.1. ALL PIPING PASSING THROUGH SMOKE OR FIRE RATED WALLS, FLOORS, OR
CEILINGS SHALL HAVE STEEL SLEEVES EXTENDING 2" BEYOND THE RATED
SURFACE. THE ANNULAR SPACE BETWEEN THE PIPING AND THE SLEEVE
SHALL BE COMPLETELY SEALED WITH APPROVED FIRE STOPPING MATERIAL.
PIPE INSULATION:
6.1. INSULATION SHALL BE OWENS CORNING, CERTAIN-TEED, KNAUF OR
APPROVED EQUAL. ALL INSULATION, MASTICS, ADHESIVES, COVERS AND
RELATED WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS AND PUBLISHED LITERATURE.
MATERIALS SHALL MEET REQUIREMENTS OF THE ADHESIVE AND SEALANT
COUNCIL STANDARDS.
6.2. ALL INSULATION (AS INSTALLED) SHALL HAVE COMPOSITE FIRE AND SMOKE
HAZARD RATINGS AS TESTED BY PROCEDURE ASTM-E-84, MFPA-255, AND
UL-723, NOT EXCEEDING A FLAME SPREAD OF 25 AND SMOKE DEVELOPED
OF 50 WHEN COMPARED WITH RED OAK AS 100, AS PER NFPA AND NMFU
PAMPHLETS 90A AND 90B. TRANSMISSION RATES OF VAPOR BARRIERS
SHALL NOT EXCEED 0.002 PERMS.
6.3. ALL SEALERS, TAPE, ADHESIVES AND MASTICS USED IN CONJUNCTION WITH
THE INSULATION SPECIFIED HEREIN SHALL POSSESS THE MAXIMUM
POSSIBLE FIRE-SAFE REQUIREMENTS PER CODE AND SHALL BE OF A TYPE
APPROVED BY UNDERWRITERS LABORATORIES (UL), FACTORY MUTUAL (FM)
OR THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA).
2.3. PIPE, FITTINGS AND JOINTS IN PVC-DWV PIPING SYSTEMS SHALL BE
ASSEMBLED USING APPROVED SCHEDULE 40 PIPE, PVC DRAINAGE WASTE
AND VENT FITTINGS WITH SOLVENT WELDED JOINTS, ALL ASSEMBLED TO
PROVIDE A WATERTIGHT SEAL. PIPING SHALL BE CUT CLEAN, SQUARE AND
TRUE. PIPING ENDS SHALL BE SMOOTH AND FREE OF ANY BURRS. PIPE AND
FITTINGS SHALL BE FIRMLY SET, PROPERLY ALIGNED USING APPROVED
PRIMER AND SOLVENT CEMENT IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS. ALL PIPE AND FITTINGS SHALL BE
INSTALLED IN ACCORDANCE WITH THE PLASTIC PIPE INSTITUTE (PPI)
STANDARDS.
2.4. PIPE, FITTINGS AND JOINTS IN ACID RESISTANT POLYPROPYLENE PIPING
SYSTEMS SHALL BE ASSEMBLED USING APPROVED SCHEDULE 40 PIPE,
POLYPROPYLENE DRAINAGE WASTE AND VENT FITTINGS WITH FUSION SEAL
WELDED JOINTS, ALL ASSEMBLED TO PROVIDE A WATERTIGHT SEAL. PIPING
SHALL BE CUT CLEAN, SQUARE AND TRUE. PIPING ENDS SHALL BE SMOOTH
AND FREE OF ANY BURRS. PIPE AND FITTINGS SHALL BE FIRMLY SET,
PROPERLY ALIGNED AND FUSION WELDED IN ACCORDANCE WITH THE
MANUFACTURER'S INSTRUCTIONS. ALL PIPE AND FITTINGS SHALL BE
INSTALLED IN ACCORDANCE WITH THE PLASTIC PIPE INSTITUTE (PPI)
STANDARDS.
2.5. PIPE AND FITTINGS FOR THREADED STEEL, COPPER OR BRASS PIPE SHALL
BE ASSEMBLED USING APPROVED PIPE OR TUBE, IPS THREADED FITTINGS
AND IPS THREADS CUT SQUARE AND TRUE. FOR FIELD CUT THREADS, NOTE
THE INTERNAL LENGTH OF THREADS IN FITTINGS AND PROXIMITY OF
INTERNAL SEAT TO DETERMINE HOW FAR PIPE SHOULD BE THREADED INTO
JOINT. ALIGN THREADS AT POINT OF ASSEMBLY. APPLY APPROPRIATE TAPE
OR JOINT COMPOUND TO THE EXTERNAL PIPE THREADS. ASSEMBLE JOINT
TO APPROPRIATE THREAD DEPTH. DO NOT USE PIPE WITH DAMAGED
THREADS. ALL PIPE AND FITTINGS SHALL BE INSTALLED IN ACCORDANCE
WITH ANSI SPECIFICATION B120.1 FOR TAPERED PIPE THREADS.
6.4. VALVES, FITTINGS, FLANGES AND ACCESSORIES SHALL HAVE THE SAME
INSULATION THICKNESS AS THE ADJACENT PIPE. FITTING COVERS SHALL BE
OF THE FACTORY MOLDED PLASTIC TYPE.
6.5. LONGITUDINAL SEAMS AND END JOINT SEALING STRIPS SHALL BE SEALED
WITH A FIRE RETARDANT COATING HAVING A VAPOR TRANSMISSION OF NO
MORE THAN 1.0 PERM. ENDS OF INSULATION AT TERMINATION POINTS AND
AT PIPE SUPPORTS SHALL BE SEALED WITH A BRUSH COAT OF VAPOR
BARRIER COATING.
6.6. ALL WATER AND HOT WATER / RECIRC PIPING AND FITTINGS SHALL BE I
INSULATED WITH FIBERGLASS INSULATION AND ALL SERVICE VAPOR
JACKET.
THICKNESS (MINIMUM) AS FOLLOWS:
6.6.1. COLD WATER IN HEATED SPACE, 1/2".
6.6.2. COLD WATER AND TRAP PRIMER LINES HEAT TRACED IN UNHEATED
SPACE, 1".
6.6.3. HOT WATER / RECIRC UNDER 11/2" DIAMETER, 1".
6.6.4. HOT WATER / RECIRC 11/2" DIAMETER AND OVER, 11/2".
7.
ANY ABOVE GROUND RAIN / STORM WATER PIPING AND FITTINGS (INCLUSIVE OF
ROOF DRAIN BODIES) SHALL BE INSULATED WITH ONE INCH THICK FIBERGLASS
INSULATION AND ALL SERVICE VAPOR JACKET. DUCT WRAP SHALL NOT BE
ALLOWED ON PIPING.
8.
ABOVE GROUND SANITARY WASTE PIPING HEAT TRACED IN UNHEATED AREAS
SHALL BE THE SAME AS FOR RAIN / STORM WATER ABOVE AND BE 1" THICK.
9.
CLEANOUTS:
9.1. SHALL BE AS MANUFACTURED BY JR SMITH, JOSAM, ZURN OR APPROVED
EQUAL. REFER TO THE DRAWINGS AND SCHEDULES FOR TYPES AND
PERFORMANCE CRITERIA.
9.2. CLEANOUTS IN CAST IRON WASTE PIPING SHALL BE STANDARD PIPE SIZE
CONFORMING IN THICKNESS TO THAT REQUIRED FOR PIPE AND FITTINGS
AND SHALL EXTEND NOT LESS THAN 3/4" ABOVE THE HUB OF THE PIPE. THE
CLEANOUT PLUG SHALL BE OF CAST BRASS AND SHALL BE PROVIDED WITH
A RAISED NUT, 3/4" HIGH. CLEANOUTS IN COPPER WASTE PIPING SHALL BE
SOLDERED CAST BRASS CLEANOUT FITTINGS WITH EXTRA HEAVY BRASS
SCREW PLUGS OF THE SAME SIZE AS THE PIPING.
10. ACCESS PANELS:
10.1.
ACCESS PANELS SHALL BE AS MANUFACTURED BY MICRO PRODUCTS,
VENTLOCK, KNAPP OR APPROVED EQUAL. MINIMUM SIZE SHALL BE 12"x12".
ACCESS PANELS SHALL BE FIRE RATED WHERE REQUIRED.
10.2.
FURNISH ACCESS PANELS AS REQUIRED FOR PIPING COMPONENTS AND
EQUIPMENT SUCH AS CLEANOUTS, VALVES, SHOCK ARRESTERS, ETC.,
LOCATED WITHIN CONCEALED WALLS AND CEILINGS. PIPING SHALL BE LAID
OUT IN SUCH A MANNER AS TO MINIMIZE THE NUMBER OF ACCESS PANELS
REQUIRED. LOCATE COMPONENTS REQUIRING ACCESS ABOVE ACCESSIBLE
CEILINGS WHERE POSSIBLE. COORDINATE THE LOCATION OF ACCESS
PANELS WITH THE GENERAL CONTRACTOR AND APPROPRIATE SUBCONTRACTOR FOR PROPER INSTALLATION.
11. PLUMBING FIXTURES:
11.1.
PROVIDE PLUMBING FIXTURES AND TRIM COMPLETE WITH FAUCETS,
FIXTURE CARRIERS, DRAIN OUTLETS, TAILPIECES, P-TRAPS AND STOPS AND
SUPPLIES. REFER TO THE DRAWING SCHEDULES FOR FIXTURE TYPES,
MODEL NUMBERS AND PERFORMANCE CRITERIA.
11.2.
VITREOUS CHINA AND ENAMELED CAST IRON PLUMBING FIXTURES SHALL
BE AS MANUFACTURED BY KOHLER, AMERICAN STANDARD, ELJER OR
APPROVED EQUAL. STAINLESS STEEL SINKS SHALL BE AS MANUFACTURED
BY ELKAY, JUST, OR APPROVED EQUAL. WATER COOLERS SHALL BE AS
MANUFACTURED BY HALSEY TAYLOR, ELKAY, OASIS, OR APPROVED EQUAL.
MOP RECEPTORS AND SERVICE SINKS SHALL BE AS MANUFACTURED BY
FIAT, STERN-WILLIAMS, MUSTEE, OR APPROVED EQUAL.
11.3.
PLUMBING FIXTURE FAUCETS AND TRIM SHALL BE AS MANUFACTURED
BY KOHLER, AMERICAN STANDARD, ELJER OR APPROVED EQUAL.
11.4.
EMERGENCY EYE AND FACE WASH FIXTURES SHALL BE AS
MANUFACTURED BY GUARDIAN OR APPROVED EQUAL.
11.5.
DRAINAGE SPECIALTIES SUCH AS FLOOR DRAINS, AREA DRAINS, ROOF
DRAINS AND CLEAN OUTS SHALL BE AS MANUFACTURED BY WATTS, JR
SMITH, ZURN OR APPROVED EQUAL.
11.6.
STOPS AND SUPPLIES SHALL BE AS MANUFACTURED BY KOHLER,
AMERICAN STANDARD, ELJER, McGUIRE, OR APPROVED EQUAL. STOPS AND
SUPPLIES SHALL BE COPPER SWEAT EXTENSION TYPE WITH COPPER RISER,
ESCUTCHEON, LOOSE KEY UNLESS OTHERWISE NOTED AND CHROME
PLATED BRASS WHERE EXPOSED.
11.7.
P-TRAPS SHALL BE 17 GAUGE CAST BRASS WITH CLEANOUT, CHROME
PLATED WHERE EXPOSED. TRAPS SHALL BE 11/4"x11/2" FOR LAVATORIES
AND 11/2"x11/2" FOR SINKS.
11.8.
FIXTURES DESIGNATED FOR BARRIER FREE USE SHALL BE MOUNTED IN
ACCORDANCE WITH THE AMERICANS WITH DISABILITIES ACT (ADA) AS WELL
AS MAAB, STATE AND LOCAL CODES.
12. PLUMBING EQUIPMENT:
12.1.
PROVIDE PLUMBING EQUIPMENT COMPLETE WITH ALL ASSOCIATED
SERVICE VALVES, DRAIN VALVES, COMPONENTS AND MOUNTING
HARDWARE AS REQUIRED FOR A COMPLETE INSTALLATION. REFER TO THE
DRAWING SCHEDULES FOR EQUIPMENT TYPES, MODEL NUMBERS AND
PERFORMANCE CRITERIA.
12.2.
DOMESTIC WATER HEATERS SHALL BE AS MANUFACTURED BY AO
SMITH, STATE, RHEEM, OR APPROVED EQUAL.
12.3.
HOT WATER RECIRC PUMPS SHALL BE AS MANUFACTURED BY TACO,
BELL & GOSSETT, THRUSH OR APPROVED EQUAL.
12.4.
GAS, SAND AND OILY WATER RETENTION WATERTIGHT GAS AND SAND
TRAP SHALL BE AS MANUFACTURED BY SHEA CONCRETE PRODUCTS OR
APPROVED EQUAL.
13. HEAT TRACING
13.1.
HEAT TRACING SHALL BE CHROMALOX CPR CABLE SELF- REGULATING
POLYMER CORE CABLE AND CONNECTIONS KITS, OR EQUAL, CUT-TOLENGTH 3 WATTS/FT 208-277V AND FEATURES 16 GAUGE COPPER BUS
WIRES TO PERMIT MAXIMIZE CIRCUIT LENGTHS.
3.
4.
5.
6.
7.
273 CORPORATE DRIVE
PORTSMOUTH, NH 03801
T 603.436.2551
F 603.436.6973
www.jsainc.com
DESIGN ARCHITECT
Bexhill Group
1907 Sabine Street, Suite 140
Houston, TX 77007
713 300 4999
VALVES AND SPECIALTIES INSTALLATION:
3.1. VALVES SHALL BE INSTALLED ON ALL COLD AND HOT WATER SYSTEMS,
ABOVE ACCESSIBLE CEILINGS, AT ALL BRANCHES FROM MAINS, GROUPS OF
PLUMBING FIXTURES, EQUIPMENT SOURCES AND OTHER LOCATIONS AS
REQUIRED TO FACILITATE THE SHUT-DOWN, DRAINING, RE-FILLING AND
MAINTENANCE OF SYSTEMS.
3.2. SHOCK ARRESTERS SHALL BE INSTALLED ON ALL COLD AND HOT WATER
PIPING, ABOVE ACCESSIBLE CEILINGS, AT GROUPS OF PLUMBING FIXTURES
OR EQUIPMENT THAT MAY PRODUCE WATER HAMMER IN ACCORDANCE
WITH PDI STANDARD WH201.
PLUMBING FIXTURE AND EQUIPMENT INSTALLATION:
4.1. INSTALL PLUMBING FIXTURES, FAUCETS, TRIM, CARRIERS, STOPS, SUPPLIES
AND ALL RELATED COMPONENTS IN ACCORDANCE WITH THE
MANUFACTURES USERS RECOMMENDATIONS.
4.2. EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH LOCAL, STATE AND
FEDERAL CODES AND MANUFACTURE'S APPROVED LITERATURE.
INSTALLATION OF EQUIPMENT SHALL PERMIT ACCESSIBILITY FOR SERVICE,
REPAIR AND REPLACEMENT. EQUIPMENT THAT IS COMPRISED OF PUMPS
OR MOTORS SHALL BE PROVIDED WITH SPRING VIBRATION ISOLATION
MOUNTS OR HANGERS TO MINIMIZE SOUND AND VIBRATION TRANSMISSION
TO THE BUILDING STRUCTURE. VIBRATION ISOLATORS SHALL HAVE 95"
EFFICIENCY AT ALL FREQUENCIES.
4.3. PROVIDE FACTORY START-UP, SHAKE DOWN AND COMMISSIONING FOR ALL
EQUIPMENT PROVIDED UNDER THIS SECTION. TRAINED FACTORY
PERSONNEL SHALL ENSURE PROPER START-UP, COMMISSIONING AND
OPERATION OF EACH PIECE OF EQUIPMENT. NOTIFY THE OWNER AND
ARCHITECT/ENGINEER IN ADVANCE SO THAT PERSONNEL MAY WITNESS ALL
START-UPS. PROVIDE FACTORY TRAINING IN THE OPERATION OF ALL
EQUIPMENT TO THE OWNER'S DESIGNATED PERSONNEL.
CLEANING, FLUSHING AND PROJECT MAINTENANCE:
5.1. FLUSH ALL SYSTEMS UNTIL CLEAN. DISINFECT ALL POTABLE COLD AND HOT
WATER SYSTEMS WITH CHLORINE IN ACCORDANCE WITH THE PLUMBING
CODE REQUIREMENTS. ADJUST ALL SYSTEMS FOR PROPER WATER FLOW
AND TEMPERATURE AS REQUIRED.
5.2. UNUSED MATERIAL AND WASTE DEBRIS RESULTING FROM THE
PERFORMANCE OF WORK SHALL BE REMOVED ON A REGULAR BASIS TO AN
ONSITE LOCATION. HAZARDOUS MATERIALS AND WASTE SHALL BE
DISPOSED OF IN ACCORDANCE WITH THE EPA AND ALL LOCAL, STATE AND
NATIONAL CODES OR ORDINANCES.
TESTING, BALANCING AND ADJUSTING:
6.1. TEST AND PROVIDE INSPECTIONS FOR ALL SYSTEMS IN ACCORDANCE WITH
THE PLUMBING CODE. SANITARY WASTE AND VENT SYSTEMS SHALL BE
TESTED WITH A MINIMUM OF 10 FOOT HEAD OF WATER. DOMESTIC WATER
SYSTEMS SHALL BE TESTED WITH POTABLE WATER UNDER A MINIMUM
PRESSURE OF 150 PSIG OR 1.50 TIMES THE WORKING STREET PRESSURE.
GAS SYSTEMS SHALL BE TESTED UNDER A MINIMUM PRESSURE OF 100 PSIG
AND SUBJECT TO LOCAL INSPECTION.
6.2. UPON COMPLETION OF EACH SYSTEM TEST, PROVIDE COMPLIANCE TEST
CERTIFICATES FOR EACH SYSTEM AS NOTED ABOVE.
6.3. BALANCE AND ADJUST THE DOMESTIC HOT WATER RECIRC SYSTEM IN
ACCORDANCE WITH THE PLUMBING CODE. CHECK THE OPERATION OF
EVERY PUMP, MOTOR, DRIVE AND DAMPER OPERATOR. MAKE ALL
REQUIRED BALANCING AND ADJUSTMENTS TO BRING THE SYSTEM TO
WITHIN PLUS OR MINUS 5% OF THE DESIGN CONDITIONS.
CIVIL
Hoyle Tanner & Associates, Inc.
Pease International Tradeport
100 International Drive, Suite 360
Portsmouth, NH 03801
603-413-2904
STRUCTURAL
Summit Engineering
5 Greenleaf Woods Drive, #302
Portsmouth, NH 03801
t. (603) 319-1817
MEP FP
CSI Engineering LLC
Portsmouth, NH 03801
Tel # 603-319-8244
hvac
CSI
Engineering
fire protection
plumbing
3.
RELATED DOCUMENTS AND GENERAL REQUIREMENTS:
1.1. THIS PLUMBING CONTRACTOR SHALL PROVIDE "CERTIFICATE OF
INSURANCE" SHOWING CONTRACTOR'S LIABILITY INSURANCE IN AMOUNTS
AS REQUIRED BY THE OWNER.
1.2. REVIEW ALL ARCHITECTURAL, STRUCTURAL, CIVIL, HVAC, ELECTRICAL, FIRE
PROTECTION AND PLUMBING DRAWINGS TO IDENTIFY CONDITIONS
AFFECTING THE WORK OF THIS SECTION. VISIT SITE AND NOTE EXISTING
CONDITIONS. NOTIFY ANY DISCREPANCIES TO THE ARCHITECT IN WRITING.
1.3. ALL WORK COVERED CONSISTS OF FURNISHING ALL MATERIALS, LABOR,
EQUIPMENT AND SUPPLIES NECESSARY TO PROVIDE A COMPLETE WORKING
SYSTEM REQUIRED PER THE DESIGN DRAWINGS AND MASSACHUSETTS
STATE CODES.
1.4. ALL EQUIPMENT AND MATERIALS FURNISHED UNDER THE PLUMBING
CONTRACT, LABOR, AND TESTING PERFORMED HEREIN SHALL BE IN
COMPLETE ACCORDANCE WITH THE MASSACHUSETTS STATE BUILDING
CODE, INTERNATIONAL FUEL GAS CODE, STATE PLUMBING CODE, LOCAL
ORDINANCES AND REGULATIONS OF THE CITY OR TOWN, NATIONAL FIRE
PROTECTION ASSOCIATION AND INSURANCE REGULATIONS AND
REQUIREMENTS GOVERNING SUCH WORK.
1.5. PRIOR TO BID: THE PLUMBING SUBCONTRACTOR SHALL VISIT THE SITE AND
FAMILIARIZE HIMSELF WITH ALL TRADE DRAWINGS AND ASPECTS OF THE
SCOPE AND EXISTING CONDITIONS TO WHICH THE WORK WILL BE
INSTALLED. ANY DISCREPANCIES BETWEEN THE SCOPE OF WORK SHOWN
ON THE DRAWINGS AND ANY CONDITIONS SHALL BE SUBMITTED TO THE
ARCHITECT IN WRITING. FAILURE OF THE CONTRACTOR TO DO SO SHALL
NOT CONSTITUTE AN EXTRA TO THE CONTRACT.
1.6. THIS CONTRACTOR SHALL CAREFULLY COORDINATE ALL WORK INSTALLED
WITH THAT OF ALL OTHER TRADES. PROTECT ALL NEW AND EXISTING WORK
BEFORE, DURING AND AFTER INSTALLATION.
1.7. CERTIFICATES OF APPROVAL: UPON COMPLETION OF ALL WORK, THE
PLUMBING SUBCONTRACTOR SHALL FURNISH, IN DUPLICATE, CERTIFICATES
OF INSPECTIONS FROM ALL INSPECTORS AND AUTHORITIES HAVING
JURISDICTION, NOTARIZED LETTERS FROM THE MANUFACTURERS STATING
THAT AUTHORIZED FACTORY ENGINEERS HAVE INSPECTED AND TESTED
THE INSTALLATION OF THEIR RESPECTIVE SYSTEMS AND FOUND TO BE IN
PERFECT OPERATING CONDITION.
1.8. DEMOLITION WORK: PARTICULAR CARE SHALL BE TAKEN TO AVOID
CREATING HAZARDS ON THE SITE OR CAUSING DISRUPTION OF SERVICE IN
THE BUILDING. ALL EXISTING EQUIPMENT TO BE REMOVED SHALL BE DONE
IN A NEAT AND WORKMANLIKE MANNER. ALL EXISTING EQUIPMENT TO BE
TURNED OVER TO THE OWNER SHALL BE PRESENTED TO THE OWNER IN
GOOD CONDITION AT A LOCATION DESIGNATED BY THE OWNER. ALL OTHER
EQUIPMENT SHALL BE REMOVED FROM THE PREMISES. REMOVE ALL
ABANDONED PIPING AND EQUIPMENT NOT BUILT INTO BUILDING
CONSTRUCTION. WHERE CEILING OR WALLS ARE REMOVED, ALL
ABANDONED PIPING SHALL BE REMOVED AND ENDS OF LIVE SERVICES
CAPPED. ABANDONED ELEMENTS BUILT INTO WALLS OR LOCATED ABOVE
EXISTING INACCESSIBLE CEILINGS SHALL REMAIN AND ENDS CAPPED AND
MARKED ABANDONED.
1.9. CONTINUITY OF SERVICES: SERVICES SHALL NOT BE INTERRUPTED
WITHOUT OWNER'S APPROVAL. WHEN AN INTERRUPTION OF SERVICE
BECOMES NECESSARY, CONTRACTOR SHALL CONSULT WITH THE OWNER
AND SCHEDULE THE PROPER TIME TO DO THE SHUT-DOWN. SCHEDULE
MUST NOT DELAY NOR INTERFERE WITH THE PROGRESS OF THE PROJECT.
electrical
1.
This CAD Document is an
instrument of professional
service, and shall not be
used, in whole or in part, for
any project other than for
which it was created without
the express, written consent
of CSI ENGINEERING LLC.
Any unauthorized use,
reuse, modification or
alteration, including
automated conversion of
this document shall be at
the user's sole risk without
liability or legal exposure to
CSI ENGINEERING LLC
©2010 - 2022 CSI
ENGINEERING LLC.
125 AVIATION AVE. SUITE 4
PORTSMOUTH, NH 03801
603-319-8244
MILLION AIR- PEASE
EXETER ROAD
PORTSMOUTH, NH 03801
Sullivan Construction, LLC.
PIPE IDENTIFICATION AND VALVE TAGS:
7.1. ALL PLUMBING SYSTEMS SHALL BE LABELED AT EACH VALVE, AT EACH
BRANCH, AT EACH PIPE PASSAGE THROUGH WALL AND AT INTERVALS OF
NOT MORE THAN 20 FEET WITH COLOR CODED SEMI-RIGID SETMARK PIPE
MARKERS WITH ARROWS INDICATING THE DIRECTION OF FLOW. ALL VALVES
SHALL BE TAGGED WITH 1-1/2 INCH DIAMETER BRASS TAGS AND NUMBERED
IN SEQUENCE FROM POINT OF ORIGIN. VALVE CHARTS SHALL BE PLACED
UNDER GLASS, FRAMED AND PRESENTED TO THE OWNER.
C. EXECUTION
1.
2.
GENERAL INSTALLATION:
1.1. INSTALL SYSTEMS PER CODE, AS STRAIGHT AND DIRECT AS POSSIBLE,
NEATLY SPACED, FORMING RIGHT ANGLES OR PARALLEL LINES WITH THE
BUILDING STRUCTURE. HORIZONTAL RUNS OF PIPING SHALL BE INSTALLED
AS HIGH AND AS TIGHT TO STRUCTURE AS POSSIBLE. IT SHALL BE POSSIBLE
TO DRAIN THE WATER FROM ALL SECTIONS PIPING. PITCH PIPING BACK TO
DRAIN VALVES AS REQUIRED. VERTICAL RISERS SHALL BE FIRMLY
SUPPORTED BY RISER CLAMPS AND HANGERS. COMPLY WITH CODE
REQUIREMENTS FOR SUPPORT SPACING AND LOCATIONS. PROVIDE
SEISMIC PROTECTION WHERE REQUIRED BY CODE.
1.2. ALL PIPING SHALL BE KEPT A SUFFICIENT DISTANCE FROM OTHER WORK SO
THAT FINISHED SURFACES ARE NOT LESS THAN 2 INCHES FROM OTHER
WORK.
1.3. COORDINATE WALL, FLOOR AND ROOF PENETRATIONS WITH THE
STRUCTURAL ENGINEER AS REQUIRED. ALL OPENINGS SHALL BE SIZED
FROM APPROVED SHOP DRAWINGS.
PIPING, FITTING AND JOINT INSTALLATION:
2.1. PIPE, FITTINGS AND JOINTS IN COPPER SYSTEMS SHALL BE ASSEMBLED
USING APPROVED COPPER TUBE, COPPER OR CAST BRASS SWEAT
FITTINGS, LEAD FREE SOLDER AND NON-CORROSIVE FLUX. PIPING SHALL BE
REAMED SMOOTH AFTER CUTTING. ALL PIPE AND FITTINGS SHALL BE
INSTALLED IN ACCORDANCE WITH THE COPPER DEVELOPMENT
ASSOCIATION (CDA) STANDARDS.
2.2. PIPE, FITTINGS AND JOINTS IN HUBLESS CAST IRON SYSTEMS SHALL BE
ASSEMBLED USING APPROVED MECHANICAL COMPRESSION TYPE
COUPLINGS CONSISTING OF NEOPRENE COLLAR, STAINLESS STEEL BOLTS
AND NUTS ALL ASSEMBLED TO PROVIDE A WATERTIGHT SEAL. PIPE,
FITTINGS AND JOINTS IN HUB AND SPIGOT CAST IRON SYSTEMS SHALL BE
ASSEMBLED USING APPROVED CAST IRON PIPE, RESILIENT RUBBER
GASKETED PUSH JOINTS AND LUBRICANT. ALL CAST IRON PIPE AND
FITTINGS SHALL BE INSTALLED IN ACCORDANCE WITH THE CAST IRON SOIL
PIPE INSTITUTE (CISPI) STANDARD 301-75 AND PAMPHLET 100.
Scale:
Date:
Project Number:
12.02.2022
2021-167
REVISIONS
NO.
DESCRIPTION
DATE
PROGRESS SET 12.02.2022 NOT FOR CONSTRUCTION
SPECIFICATIONS
P4.01
COPYRIGHT C 2022
Download