Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 1 13.07.2023 Specifier's comments: 1 Input data Anchor type and diameter: HIT-HY 200-A + HAS-U 8.8 HDG M24 Return period (service life in years): 50 Item number: not available (element) / 2022696 HIT-HY 200-A (adhesive) Effective embedment depth: hef,opti = 280.0 mm (hef,limit = 480.0 mm) Material: 8.8 Evaluation Service Report: ETA 11/0493 Issued I Valid: 10.12.2021 | - Proof: Design Method EN 1992-4, Chemical Stand-off installation: eb = 0.0 mm (no stand-off); t = 20.0 mm Anchor plate : lx x ly x t = 400.0 mm x 400.0 mm x 20.0 mm; (Recommended plate thickness: not calculated) Profile: IPBi/HEA, IPBI 120 / HE 120 A; (L x W x T x FT) = 114.0 mm x 120.0 mm x 5.0 mm x 8.0 mm Base material: cracked concrete, C25/30, fc,cyl = 25.00 N/mm ; h = 800.0 mm, Temp. short/long: 40/24 °C, User-defined partial material safety factor gc = 1.500 Installation: hammer drilled hole, Installation condition: Dry Reinforcement: reinforcement spacing < 150 mm (any Ø) or < 100 mm (Ø <= 10 mm) R 2 with longitudinal edge reinforcement d >= 12.0 [mm] + close mesh (stirrups, hangers) s <= 100.0 [mm] R - The anchor calculation is based on a rigid anchor plate assumption. Geometry [mm] & Loading [kN, kNm] Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 1 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 2 13.07.2023 1.1 Load combination Case Description Forces [kN] / Moments [kNm] Seismic Fire Max. Util. Anchor [%] 1 Max Fx N = -114.075; Vx = -0.091; Vy = -37.197; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 58 2 Min Fx N = 103.610; Vx = 0.109; Vy = 37.254; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 99 3 Max Fy N = -123.447; Vx = -0.125; Vy = -36.682; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 57 4 Min Fy N = 105.110; Vx = 0.106; Vy = 37.246; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 100 5 Max Fz N = 13.038; Vx = -11.197; Vy = 0.029; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 18 6 Min Fz N = -37.856; Vx = 11.201; Vy = -0.070; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 18 7 Max Mx N = -10.472; Vx = 0.011; Vy = 0.598; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 1 8 Min Mx N = -10.472; Vx = 0.011; Vy = 0.598; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 1 9 Max My N = -115.575; Vx = -0.088; Vy = -37.189; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 58 10 Min My N = 105.110; Vx = 0.106; Vy = 37.246; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 100 11 Max Mz N = -10.472; Vx = 0.011; Vy = 0.598; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 1 12 Min Mz N = -10.472; Vx = 0.011; Vy = 0.598; Mx = 0.000; My = 0.000; Mz = 0.000; Nsus = 0.000; Mx,sus = 0.000; My,sus = 0.000; no no 1 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 2 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 3 13.07.2023 2 Load case/Resulting anchor forces y 3 Controlling load case: 10 Min My 4 Anchor reactions [kN] Tension force: (+Tension, -Compression) Anchor Tension force Shear force Shear force x Shear force y 1 26.277 9.312 0.026 9.312 2 26.277 9.312 0.026 9.312 3 26.277 9.312 0.026 9.312 4 26.277 9.312 0.026 9.312 max. concrete compressive strain: max. concrete compressive stress: x Tension 1 - [‰] 2 2 - [N/mm ] resulting tension force in (x/y)=(0.0/0.0): 105.110 [kN] resulting compression force in (x/y)=(0.0/0.0): 0.000 [kN] Anchor forces are calculated based on the assumption of a rigid anchor plate. Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 3 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 4 13.07.2023 3 Tension load (EN 1992-4, Section 7.2.1) Load [kN] Capacity [kN] Utilization bN [%] Status Steel Strength* 26.277 188.267 14 OK Combined pullout-concrete cone failure** 105.110 176.261 60 OK Concrete Breakout Failure** 105.110 153.578 69 OK Splitting failure** 105.110 246.924 43 OK * highest loaded anchor **anchor group (anchors in tension) 3.1 Steel Strength N NEd £ NRd,s = Rk,s gM,s EN 1992-4, Table 7.1 NRk,s [kN] gM,s NRd,s [kN] NEd [kN] 282.400 1.500 188.267 26.277 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 4 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 5 13.07.2023 3.2 Combined pullout-concrete cone failure N NEd £ NRd,p = Rk,p gM,p 0 NRk,p = NRk,p · 0 EN 1992-4, Table 7.1 Ap,N 0 Ap,N · y g,Np · y s,Np · y re,N · y ec1,Np · y ec2,Np EN 1992-4, Eq. (7.13) NRk,p y sus = y sus · t Rk · p · d · hef =1 EN 1992-4, Eq. (7.14) EN 1992-4, Eq. (7.14a) scr,Np = 7.3 · d · √y sus · t Rk £ 3 · hef 0,5 s 0 0 = y g,Np · (y g,Np - 1) ³ 1.00 s EN 1992-4, Eq. (7.15) ( ) y g,Np EN 1992-4, Eq. (7.17) cr,Np 0 y g,Np = √n - (√n - 1) · t Rk,c = (tt ) 1,5 Rk Rk,c ³ 1.00 EN 1992-4, Eq. (7.18) k3 · √hef · fck p·d c = 0.7 + 0.3 · 1.00 ccr,Np £ 1 = 1.00 2 · ec1,N £ 1+ scr,Np 1 = 1.00 2 · ec2,N £ 1+ scr,Np cmax smax , · hef = max ccr,Np scr,Np y s,Np y ec1,Np y ec2,Np ' hef EN 1992-4, Eq. (7.20) ( ) EN 1992-4, Eq. (7.21) ( ( ) EN 1992-4, Eq. (7.21) 2 ) 0 2 Ap,N [mm ] Ap,N [mm ] 722,500 372,396 ' hef EN 1992-4, Eq. (7.19) [mm] 203.4 ' ccr,Np [mm] 305.1 EN 1992-4, Eq. (7.9) 2 scr,Np [mm] ccr,Np [mm] cmin [mm] fc,cyl [N/mm ] 18.00 743.3 371.7 270.0 25.00 ' scr,Np [mm] 610.2 yc t Rk,cr [N/mm ] k3 t Rk,c [N/mm ] y g,Np 0 y g,Np 1.023 9.20 7.700 7.28 1.000 1.000 ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np 0.0 1.000 0.0 1.000 0.965 1.000 y sus asus y sus 0.740 0.000 1.000 0 0 NRk,p [kN] 141.148 2 t Rk,ucr,20 [N/mm ] 2 2 NRk,p [kN] gM,p NRd,p [kN] NEd [kN] 264.391 1.500 176.261 105.110 Group anchor ID 1-4 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 5 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 6 13.07.2023 3.3 Concrete Breakout Failure N NEd £ NRd,c = Rk,c gM,c EN 1992-4, Table 7.1 0 NRk,c = NRk,c · 0 Ac,N 0 Ac,N · y s,N · y re,N · y ec1,N · y ec2,N · y M,N 1,5 EN 1992-4, Eq. (7.1) NRk,c = k1 · √fck · hef EN 1992-4, Eq. (7.2) 0 Ac,N = scr,N · scr,N EN 1992-4, Eq. (7.3) y s,N = 0.7 + 0.3 · y ec1,N = y ec2,N 1+ ( 1+ ( = y M,N c 1.00 ccr,N £ 1 2 · eN,1 scr,N 1 2 · eN,2 scr,N EN 1992-4, Eq. (7.4) ) £ 1.00 EN 1992-4, Eq. (7.6) ) £ 1.00 EN 1992-4, Eq. (7.6) =1 ' hef = max 2 EN 1992-4, Eq. (7.7) ( cmax smax , ccr,N scr,N )·h 0 2 Ac,N [mm ] Ac,N [mm ] 722,500 291,600 ' hef ' ccr,N [mm] [mm] EN 1992-4, Eq. (7.9) ef 2 ccr,N [mm] scr,N [mm] fc,cyl [N/mm ] 420.0 840.0 25.00 ' scr,N [mm] 180.0 270.0 540.0 ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N 0.0 1.000 0.0 1.000 1.000 1.000 gM,c NRd,c [kN] NEd [kN] 1.500 153.578 105.110 z [mm] y M,N k1 0.0 1.000 7.700 0 NRk,c [kN] 92.976 Group anchor ID 1-4 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 6 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 7 13.07.2023 3.4 Splitting failure N NEd £ NRd,sp = Rk,sp gMsp EN 1992-4, Table 7.1 0 NRk,sp = NRk,sp · 0 Ac,N 0 Ac,N · y s,N · y re,N · y ec1,N · y ec2,N · y h,sp EN 1992-4, Eq. (7.23) = min (N0Rk,p, N0Rk,c) NRk,sp 0 Ac,N = scr,sp · scr,sp y s,N = 0.7 + 0.3 · y ec1,N = y ec2,N 1+ ( 1+ ( = y h,sp = 2 1.00 ccr,sp £ 1 2 · eN,1 scr,sp 1 2 · eN,2 scr,sp (hh ) min EN 1992-4, Eq. (7.3) c ) £ 1.00 EN 1992-4, Eq. (7.6) ) £ 1.00 EN 1992-4, Eq. (7.6) 2/3 £ max {1; (h 0 2 Ac,N [mm ] Ac,N [mm ] 722,500 291,600 ' hef [mm] EN 1992-4, Eq. (7.4) ' ccr,sp [mm] ef + 1.5· c1 hmin ) } £ 2.00 2/3 EN 1992-4, Eq. (7.24) ccr,sp [mm] scr,sp [mm] y h,sp fc,cyl [N/mm ] 280.0 560.0 1.608 25.00 ' scr,sp 2 [mm] 270.0 270.0 540.0 ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N k1 0.0 1.000 0.0 1.000 1.000 1.000 7.700 gM,sp NRd,sp [kN] NEd [kN] 1.500 246.924 105.110 0 NRk,sp [kN] 92.976 Group anchor ID 1-4 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 7 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 8 13.07.2023 4 Shear load (EN 1992-4, Section 7.2.2) Utilization bV [%] Status 112.960 9 OK N/A N/A N/A 37.246 307.156 13 OK 37.246 65.019 58 OK Load [kN] Capacity [kN] 9.312 N/A Pryout Strength** Concrete edge failure in direction y+** Steel Strength (without lever arm)* Steel failure (with lever arm)* * highest loaded anchor **anchor group (relevant anchors) 4.1 Steel Strength (without lever arm) V VEd £ VRd,s = Rk,s gM,s VRk,s = k7 · 0 0 VRk,s EN 1992-4, Table 7.2 EN 1992-4, Eq. (7.35) VRk,s [kN] k7 VRk,s [kN] gM,s VRd,s [kN] VEd [kN] 141.200 1.000 141.200 1.250 112.960 9.312 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 8 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 9 13.07.2023 4.2 Pryout Strength (Concrete Breakout Strength controls) V VEd £ VRd,cp = Rk,cp gM,c,p VRk,cp = k8 · min {NRk,c; NRk,p} A 0 NRk,c = NRk,c · 0c,N · y s,N · y re,N · y ec1,N · y ec2,N · y M,N Ac,N EN 1992-4, Table 7.2 EN 1992-4, Eq. (7.39c) EN 1992-4, Eq. (7.1) 0 = k1 · √fck · hef EN 1992-4, Eq. (7.2) Ac,N 0 = scr,N · scr,N EN 1992-4, Eq. (7.3) y s,N = 0.7 + 0.3 · y ec1,N = 1,5 NRk,c y ec2,N 1+ ( 1+ ( = y M,N c 1.00 ccr,N £ 1 2 · eV,1 scr,N 1 2 · eV,2 scr,N EN 1992-4, Eq. (7.4) ) £ 1.00 EN 1992-4, Eq. (7.6) ) £ 1.00 EN 1992-4, Eq. (7.6) =1 ' hef = max 2 EN 1992-4, Eq. (7.7) ( cmax smax , ccr,N scr,N )·h 0 2 Ac,N [mm ] Ac,N [mm ] 722,500 291,600 ' hef ' ccr,N [mm] 180.0 [mm] EN 1992-4, Eq. (7.9) ef 2 ccr,N [mm] scr,N [mm] k8 fc,cyl [N/mm ] 420.0 840.0 2.000 25.00 ' scr,N [mm] 270.0 540.0 ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N y M,N 0.0 1.000 0.0 1.000 1.000 1.000 1.000 k1 NRk,c [kN] 0 gM,c,p VRd,cp [kN] VEd [kN] 7.700 92.976 1.500 307.156 37.246 Group anchor ID 1-4 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 9 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 10 13.07.2023 4.3 Concrete edge failure in direction y+ V VEd £ VRd,c = Rk,c gM,c EN 1992-4, Table 7.2 Ac,V 0 VRk,c = kT · VRk,c · b a 0 · y s,V · y h,V · y a,V · y ec,V · y re,V 0 Ac,V 1,5 = k9 · dnom · lf · √fck · c1 VRk,c lf c1 = 0.1 · EN 1992-4, Eq. (7.41) 0,5 () d = 0.1 · ( c ) a EN 1992-4, Eq. (7.42) 0,2 nom b EN 1992-4, Eq. (7.40) EN 1992-4, Eq. (7.43) 1 0 Ac,V = 4.5 · y s,V c2 1.00 = 0.7 + 0.3 · 1.5 · c1 £ y h,V = y ec,V = = EN 1992-4, Eq. (7.44) (1.5h· c ) ( EN 1992-4, Eq. (7.45) 0,5 1 1+ y a,V 2 c1 1 2 · eV 3 · c1 ) ³ 1.00 EN 1992-4, Eq. (7.46) £ 1.00 EN 1992-4, Eq. (7.47) √(cos a ) + (10.5 · sin a ) 2 V V lf [mm] dnom [mm] 280.0 24.00 2 ³ 1.00 EN 1992-4, Eq. (7.48) k9 1.700 2 0 Ac,V a b fc,cyl [N/mm ] 0.102 0.062 25.00 2 2 [mm ] c1 [mm] Ac,V [mm ] 270.0 344,250 328,050 y s,V y h,V aV [°] y a,V ec,V [mm] y ec,V y re,V 0.900 1.000 0.08 1.000 0.0 1.000 1.400 kT gM,c VRd,c [kN] VEd [kN] 1.0 1.500 65.019 37.246 0 VRk,c [kN] 73.761 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 10 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 11 13.07.2023 5 Combined tension and shear loads (EN 1992-4, Section 7.2.3) Steel failure a bN bV a Utilization bN,V [%] Status 0.140 0.082 2.000 3 OK a bN + bV £ 1.0 Concrete failure a bN bV a Utilization bN,V [%] Status 0.684 0.573 1.500 100 OK a bN + bV £ 1.0 6 Displacements (highest loaded anchor) Short term loading: NSk VSk = = 19.465 [kN] dN = 0.0645 [mm] 6.897 [kN] dV = 0.2069 [mm] dNV = 0.2168 [mm] Long term loading: NSk = 19.465 [kN] dN = 0.1475 [mm] VSk = 6.897 [kN] dV = 0.3449 [mm] dNV = 0.3751 [mm] Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not included in this calculation! The acceptable anchor displacements depend on the fastened construction and must be defined by the designer! Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 11 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: | Efix man hea120 Page: Specifier: E-Mail: Date: 12 13.07.2023 7 Warnings • The anchor design methods in PROFIS Engineering require rigid anchor plates per current regulations (AS 5216:2021, ETAG 001/Annex C, EOTA TR029 etc.). This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Engineering calculates the minimum required anchor plate thickness with CBFEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the rigid anchor plate assumption is valid is not carried out by PROFIS Engineering. Input data and results must be checked for agreement with the existing conditions and for plausibility! • Checking the transfer of loads into the base material is required in accordance with EN 1992-4, Annex A! • The design is only valid if the clearance hole in the fixture is not larger than the value given in Table 6.1 of EN 1992-4! For larger diameters of the clearance hole see section 6.2.2 of EN 1992-4! • The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to be followed to ensure a proper installation. • For the determination of the y re,v (concrete edge failure) the minimum concrete cover defined in the design settings is used as the concrete cover of the edge reinforcement. • Bore hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice, blow twice with oil-free compressed air (min. 6 bar)). • Characteristic bond resistances depend on short- and long-term temperatures. • Edge reinforcement is not required to avoid splitting failure • The characteristic bond resistances depend on the return period (service life in years): 50 Fastening meets the design criteria! Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 12 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: Page: Specifier: E-Mail: Date: | Efix man hea120 13 13.07.2023 8 Installation data 2 Anchor plate, steel: Custom anchor plate material; E = 200,000.00 N/mm ; fyk = Anchor type and diameter: HIT-HY 200-A + HAS-U 8.8 2 HDG M24 250.00 N/mm Profile: IPBi/HEA, IPBI 120 / HE 120 A; (L x W x T x FT) = 114.0 mm x 120.0 Item number: not available (element) / 2022696 HIT-HY mm x 5.0 mm x 8.0 mm 200-A (adhesive) Hole diameter in the fixture: df = 26.0 mm Maximum installation torque: 200 Nm Plate thickness (input): 20.0 mm Hole diameter in the base material: 28.0 mm Recommended plate thickness: not calculated Hole depth in the base material: 280.0 mm Drilling method: Hammer drilled Cleaning: Compressed air cleaning of the drilled hole according to instructions Minimum thickness of the base material: 336.0 mm for use is required Hilti HAS-U threaded rod with HIT-HY 200 injection mortar with 280 mm embedment h_ef, M24, Hot dip galvanized, Hammer drilled installation per ETA 11/0493 8.1 Recommended accessories Drilling Cleaning Setting • Suitable Rotary Hammer • Properly sized drill bit • Compressed air with required accessories to blow from the bottom of the hole • Proper diameter wire brush • Dispenser including cassette and mixer • Torque wrench y 200.0 4 310.0 200.0 3 45.0 200.0 200.0 x 2 45.0 1 45.0 310.0 45.0 Coordinates Anchor [mm] Anchor x y c-x c+x c-y c+y 1 2 3 4 -155.0 155.0 -155.0 155.0 -155.0 -155.0 155.0 155.0 270.0 580.0 270.0 580.0 580.0 270.0 580.0 270.0 270.0 270.0 580.0 580.0 580.0 580.0 270.0 270.0 Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 13 Hilti PROFIS Engineering 3.0.86 www.hilti.cz Company: Address: Phone I Fax: Design: Fastening point: | Efix man hea120 Page: Specifier: E-Mail: Date: 14 13.07.2023 9 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for conformity with the existing conditions and for plausibility! PROFIS Engineering ( c ) 2003-2023 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan 14