5.1 SYSTEM DIAGNOSIS 5.1.1 Compressor Start Relay (CSR) Testing Procedure: 1. Make sure that the refrigerator is switched off and is not plugged in. 2. Remove the lock panel of the refrigerator. 3. Locate the compressor’s pins (typically located on the lower side of the compressor). 4. Keep on track of the resistance values: a. Connect the tester’s pins to the terminal to see how the current changes throughout the process. b. Take note of the resistance readings the component that provide each reading. Table 1: Compressor Start Relay Table 2: Leak Testing Table 3: Charging Refrigerant Table 4: Cleaning by self-vacuuming Table 5: Overall Result 5. Identify each Terminal 6. Check if the compressor has a ground fault. 5.1.2 Leak Testing Procedure: 1. Be mindful of what the color-coded hoses of the auxiliary manifold gauge represent. Yellow hose for the middle auxiliary port. Red hose for the red gauge. Blue hose for the blue gauge. 2. Next, attach the hoses to their respective connection. Yellow hose to the canister. Red hose to the discharge line. Blue hose to the suction line. 3. Put soap on the water in the container. Let suds form in the sponge. 3. Perform a Leak Test a. Open the refrigerant tank that will allow the vapor to flow. b. Apply the soap suds prepared earlier to the auxiliary port and fittiing on the yellow hose. c. With the use of a mirror and flashlight, observe if bubbles are forming, this is an indication of a leak on the hose. Note: Be mindful of where the low and high pressure are. Avoid applying soap suds to the low-pressure side to avoid suction of the soap into the system. This can damage the system. 4. Repeat the process, this time, test the red hose. VI. RESULTS AND DISCUSSION 6.1 SYSTEM DIAGNOSIS 6.1.1 COMPRESSOR START RELAY TRIAL/S 1 2 COMPRESSOR START RELAY AMPERE LOW PRESSURE (Blue Side) 0.887 A 7.37 psi 0.825 A 7.37 psi Table 1: Compressor Start Relay HIGH PRESSURE (Red Side) 100 psi 115 psi DISCUSSION: 6.2.1 LEAK TESTING TRIAL/S 3 LEAK TESTING AMPERE LOW PRESSURE (Blue Side) 0.898 A 0 Table 2: Leak Testing HIGH PRESSURE (Red Side) 150 psi DISCUSSION: Since there is no bubbles form while the soap suds are applied to the auxiliary ports and fittings, the is no leakage.