Uploaded by hys.1999

impellers

advertisement
Saudi Fan Industries
S
Management Commitment To Quality
We are continuously striving to provide higher quality products and
services to achieve total customer satisfaction by understanding
their requirements and anticipating their future expectations or
needs.
We are committed to development and strengthening of partnership
with our external and internal customers and suppliers.
We are dedicated to the continual improvement of all products and
services through involvement of all employees.
We value all people by understanding and drawing upon their
strengths i.e. abilities and knowledge and make efforts for their
training and development.
President
Ali Saleh Al-Khalaf
General Technical Information
Saudi Fans Distinguished Features
Saudi Fan Industries ' fans are equipped with direct driven
external rotor motors, which have decisive advantages over
conventional fans:
Long Service Life
Compact design
The speed is 100% controllable through
auto transformer or electronic control.
Low starting currents.
Advantages of our single phase type fans.
We recommend the use of single phase fans (E), whenever
possible, which offer the following advantages:
Two or five cores plus earth cable only. Always correct
direction of rotation.
Motor protection through built-in thermal overload contacts,
wired in series with the motor winding.
Low cost speed controllers with 5 steps or electronic control,
available ex-stock.
External rotor motors
The external rotor motor drive offers features such as space
saving, compact and attractive design.
The motor is fitted within the impeller, which enables the best
possible cooling. For this reason a 100% variable speed
control can be guaranteed. V-belts, additional tension bars
and motor mountings are not necessary.
Only over-dimensioned ball-bearings (German products),
fitted on both side, sealed for life, are used. Both ball-bearing
seats are ground to high precision in one work process to
eliminate any vibrations.
External rotor motors have extremely low starting
currents.
The motors comply with protection class IP44 according to DIN
40050. Protection class IP 54 for double inlet fans is available
on request.
External rotor motor construction
Stator
Labyrinth
Insulation Class
The windings of single inlet fans comply with insulation class B,
the windings of double inlet fans comply with insulation class F.
In addition the windings have a standard moisture impregnation.
Thermal Protection
All external rotor motors except the explosion-proof motors are
equipped with thermal contacts, embedded in the windings to
protect the motor. Thermal contacts are bi-metallic cutouts,
temperature dependent, When properly wired they protect
against overload, main-phase failure, stalling of motor and too
high ambient temperatures.
Motor protection is guaranteed, when the thermal contacts are
wired through a tip contactor circuit.
In connection with thermal contacts we recommend to fit our
supplied controllers for better motor protection.
For the exhaust of explosive mixture in temperature classes
T1 to T3 in Zone 1 and 2, we offer fans with specific controllable
motors in protection class "e", for intrinsically safe application,
according to DIN 50019.
Electrical connection
Electrical connection will be made by an enclosed terminal box,
protection class IP 44. As special execution we are able to deliver
terminal box made of aluminum protection class IP 55.
Selection of Fans
The following must be considered when selecting a suitable fan;
Desired air volume and pressure loss
Possible sizes
Sound characteristics
Ambient conditions
Electrical power supply and tolerances
For the determination of the required air volume, any existing
resistance must be considered, which determine the operating
point. These losses could be from ducts and filters in front of or
behind the fan, air diffusers, heating and cooling elements and
ducts bends.
Rotor
These resistence vary at the square of the air volume and can be
described in a specific characteristics curve.
Ball bearing
Ambient operating temperature
Maximum ambient operating temperature can be taken from the
data sheets. Should the temperature indicated not be sufficient,
the possible temperature can be increased by using a larger motor
(at extra expenses).
Tube Fans
With radial impellers RS/R
Advantages of tube fans:
Simple and easy installation by use of round ducts according to DIN
Can be installed in any position
Easy electrical connection via IP 54 terminal box fitted to the outside
100% variable speed controllable via auto transformers or electronic
control
Uniting the advantages of axial fans straight airflow with high
pressure stability, low noise level and high efficiency of the radial
Built-in thermal overload protection.
Advantages of the plastic casing compared with sheet steel types:
Lower noise level
Completely corrosion resistant
Easy installation with mounting brackets
Higher pressure and better efficiency through guide vane
Lower weight
Application:
Clean air ventilation
Ventilation of commercial premises where low acoustic level is required
(shops, meeting and conference rooms)
Slightly dusty and greasy air, Slightly aggressive gases and fumes (please
refer to our engineers).
o
Mediums up to an atmospheric density of 1,2 kg/m3 .& 50 C ambient /
medium temperature
An economical series due to its compact design, can remedy problems
of low-flow ventilation.
Ranges:
Two Versions:
Metal casing
Models:
Flow rate:
Plastic casing
Models:
Flow rate:
Type : R
11 Models
up to 1350 CFM
up to 2,300 m3/h
Type : RS
9 Models
up to 558 CFM
up to 950 m3/h
Construction
Plastic casing
The size RS 100L RS 315L are equipped with an attractive, impact
strong and hardly inflammable plastic casing with integrated IP 44
terminal box and guide vane.
Metal casing
The casings of sizes R100 to R315 are manufactured of galvanized
sheet steel, the casing of R355 is made of aluminum.
Impeller
The impellers from size 100 to 250 are made from plastic
( PA 25%GF). The impeller of the RS 315 is made of plastic.
The impeller of the RS 315L is made of galvanized sheet steel.
The impeller is mounted directly to the rotor of the external rotor
motor and the motor impeller is balanced at two levels according
to quality level G 2,5 according to DIN/ISO 1940.
Motor
The 100% variable speed external rotor motors are in accordance
with protection class IP44 according to DIN 40050. Electrical
construction according to VDE 0530, and Motor winding comply to
insulation class B with moisture impregnation and built-in thermal
protection.
Electrical connection
The motors are fitted with flying lead. The electrical connection can
be made via an IP 54 terminal box.
Documentation:
Manufacturers declaration and operating instruction are according to
machinery directive 89/392/EEC, CE identification in accordance to
EMC-directive 89/336/EEC and low voltage directive 73/23/EEC.
Installation
Rigid folded spiral- seam (Spiro), flexible aluminum or plastic ducts
with standardized diameter can be used. If the tube fan is used for
several floor levels, the local laws concerning fire protection have to
be observed.
Reference Code
R
R
tube fan
S
plastic casing
8-angular
duct diameter
L
larger motor
S
315
L
Accessories
SPEED CONTROL (for single phase)
Reducing Speed for fan
Speed Controls are available in various models for different applications up to 10 Amps, this speed controller requires
50x100 handy box and its circuit is illustrated on the drawing below for (single phase motors).
Speed control (for three phase)
Guide for specification
Inline fan for Supply/Exhaust service shall be type : R/RS, size : 100 to 355L as manufactured by Saudi Fan Industries, Saudi Arabia fitted with
direct drive/ close coupled external rotor motor suitable with 127V or 220V 1Phase 50Hz or 60Hz power supply where required.
PLASTIC CASING : TYPE RS
The complete fan shall be constructed using a compact combination of external rotor motor close coupled to a backward curve centrifuga
impeller to realize best possible cooling.
The external rotor motor shall have a minimum of IP44 construction per DIN 40050; the insulation winding shall have class “B” construction with
additional protection against moisture; each external rotor motor shall be 100% compatible with standard electronic speed control by varying
fan speed from 100% to 10% of rated speed.
Each motor shall have a built in thermal overload protection.
The plastic casing shall be attractive, impact resistant, non-flammable plastic and 100% corrosion resistant.
Each fan shall be equipped with an IP 44 terminal box with a wiring diagram.
Fan shall be UL & AMCA listed.
METAL CASING : TYPE - R
Features Same as above.
The metal casing shall be manufactured using galvanized steel sheets, with the exception of size : 355 which is made of aluminum.
Fan shall be UL & AMCA listed.
Typical application
Refrigeration House Group
For contacts & inquiry
.
.
.
Head Office
Tel:(03) 882 1713 - 882 3515 Fax: (03)882 3066
Manufacturing Divisions
Dammam 2nd Industrial City
National Factory
Tel:(03) 812 1282 Fax: (03) 812 1848
Saudi Fan Industries Tel:(03) 812 1866 Fax: (03) 812 1894
Contracting Division
Klimatechnik Tel: (03) 882 3534 Fax: (03) 882 2807
Riyadh
Tel: (01) 465 6198 Fax: (01) 462 8347
Trading Divisions
Refrigeration House
Al-Khobar Tel: (03) 869 1043 Fax: (03) 898 4161
Jubail
Tel: (03) 361 5512 Fax: (03) 361 279
Riyadh
Tel: (01) 476 9720 Fax: (01) 476 9518
Jeddah
Tel: (02) 665 2276 Fax: (02) 661 2265
Bahrain Regional Office
Tel.:++973 537784 Fax:++973 537138
PETROL STATION
Al-Hassa
MODERN iNDS.C0.
(TIDE)
Al-Yaf Ind.
Abha Street
NOTIONAL
FACTORY
ABQAIQ HIGHWAY
Eastern heaters.
Al-Hamarani.
m
Dam
N
-MOO
HALF ACH
BE
Klimatechnik
S
.
.
P.O.Box.1823 - Al-Khobar.31952
SAUDI ARABIA
am
MAIN ENTRANCE
2ND INDS. CITY
DAMMAM
Gasket factory
Saudi Inds.
Solvrnt C0.
Saudi Fan Inds.
Download