Uploaded by mspeiwenlau

PID Legend Sheet

advertisement
1
2
00. LINE TYPES LEGEND
A
3
4
5
02. PIPELINE FITTINGS CONT.
MAIN PROCESS LINE
OPEN VENT
(GIVE NOTE IF RUN TO GRADE)
SECONDARY PROCESS LINE
OPEN DRAIN
6
03. VALVES CONT.
7
CYLINDER VALVE
PCV
XXXX
PRV
XXXX
BURSTING DISC
PNEUMATIC SIGNAL
B
ELECTRICAL SIGNAL
\
\
\
\
\
ELECTRICAL BINARY SIGNAL DIGITAL
PRESSURE RELIEF
OR SAFETY VALVE
SHOWING PRESSURE SETTING
PUMP, RECIPROCATING
VORTEX METER
CIRCULAR GUIDE VANE VALVE
BAND SCREEN
PUMP, DOSING
PRelV
XXXX
GAS RELIEF VALVE
SPRAY HEADER OR DIFFUSER
FI
XX
PERISTALTIC PUMP
ROTARY VALVE
FE
XX
8301PU
RUPTURE DISK (OR BURSTING
DISC)
VACUUM RELIEF
PSE
XXXX
BACK PRESSURE REGULATING
(EXTERNAL TAPPING)
04. ACTUATORS
06. ACTUATOR FAIL POSITIONS
03. VALVES
TP
VALVE SIZE INDICATED ABOVE
VALVE (GENERAL SYMBOL)
TAG No. INDICATED BELOW
B
P
THREE WAY VALVE, FAIL OPEN
TO PATH A-C
I
09. FLOW CONTROL DEVICES
C
PISTON ACTUATOR WITH
POSITIONER
GLOBE VALVE
NEEDLE VALVE
PIPE TO INSTRUMENTATION
SPECIFICATION CHANGE POINT
13. BLOWERS AND COMPRESSORS
I TO P CONVERTER
FAN
B
DIAPHRAGM ACTUATOR
C
BLOWER
INTERLOCK OR LOGIC FUNCTION
G
P
A
REDUCING VALVE
GENERATOR
PURGE OR FLUSHING DEVICE
FOUR WAY VALVE, FAIL OPEN
TO PATHS A-C & D-B
V-NOTCH WEIR
ATTENUATOR / SILENCER
D
ABOVE GROUND &
UNDERGROUND BURIED
AUTOMATIC DIAPHRAGM
ACTUATOR
DIAPHRAGM VALVE
02. PIPELINE FITTINGS
AAxBB
REDUCED PRESSURE ZONE
DEVICE
PNEUMATIC DIAPHRAGM
ACTUATOR
PENSTOCK
PRESSURE BALANCED
DIAPHRAGM ACTUATOR
BUTTERFLY VALVE
RECTANGULAR WEIR
SCREEN
THE FAILURE MODES INDICATED ARE THOSE COMMONLY
DEFINED BY THE TERM "SHELF POSITION".
AS AN ALTERNATIVE TO THE ARROWS AND BARS, THE
FOLLOWING ABBREVIATIONS MAY BE EMPLOYED:
HANDWHEEL
ANGLE VALVE
RESET OR LATCH TYPE
ACTUATOR
DRYER
ANY VALVE, FAIL INTERMEDIATE
PLUG VALVE
END CAP
AIR DRYER
R
STOPLOG OR BOARD
SPRING ACTUATOR - FOR
PRESSURE RELIEF OR SAFETY
VALVE ONLY
HOSE CONNECTION FEMALE
HOSE CONNECTION MALE
SELECTOR SWITCH
ANY VALVE, FAIL LOCKED
REDUCER
CONTROL SWITCH AND/OR
PUSHBUTTON STATION
AFTER COOLER
LUBRICATOR
VENTURI
FLOAT SWITCH
FO
XX
FILTER
F
FLOW ELEMENT, ORIFICE TYPE
D/F
AIR SUPPLY FITTING
WALL TYPE
FO - FAIL OPEN
W/F
WASHABLE FILTER
SOLENOID
ANGLE FLOAT VALVE
FC - FAIL CLOSED
BELLMOUTH
FLANGED JOINT
PLUGGED SOCKET
IN-LINE FLOAT VALVE
FLOAT
BELLOWS OR EXPANSION JOINT
AGITATOR, FAN, PROPELLER
LO - LOCKED OPEN
TRAP
P
WATER TRAP
EDUCTOR/INJECTOR/EJECTOR
PNEUMATIC ACTUATOR
STATIC IN-LINE MIXER
H
G
GEARBOX
M
H
1
Date Plotted: 25/06/2018
Plot Style: Water.ctb
DATE
2
Plotted by: Essery, Scott
DRAWN
CHECKED
3
ULTRASONIC LEVEL PROBE
DAMPER, MULTI BLADE
PARALLEL
DAMPER, FIRE
LEVEL SWITCH PADDLE
B
ISSUE
DAMPER, MULTI BLADE
OPPOSED
NC - NORMALLY CLOSED
TRAPPED VENT
No.
FLASHING LIGHT OR SIGNAL
LAMP
HYDRAULIC ACTUATOR
FOUR WAY VALVE
K. Danenbergsons
DAMPER, SINGLE BLADE
AXIAL FLOW MIXER OR
FLOCCULATOR
NO - NORMALLY OPEN
C. Dickson
AIR EXHAUST FITTING
CEILING TYPE
G
LC - LOCKED CLOSED
THREE WAY VALVE
15/06/2018
COMPRESSOR
MOTORISED
M
INITIAL ISSUE
AIR SUPPLY FITTING
CEILING TYPE
SUBMERSIBLE MIXER
SLIDE GATE VALVE
STRAINER, Y-TYPE (FLANGED)
AIR FILTER
FI - FAIL INTERMEDIATE
KNIFE GATE VALVE
FLANGED VALVE
AIR EXHAUST FITTING
WALL TYPE
10. MIXING AND FLOCCULATION
FL - FAIL LOCKED (LAST POSITION)
WEIGHT
HOSE COUPLING
A
F
DISPOSABLE FILTER
BLANKED FLANGE
G
E
S
INTERFACE POINT
F
I
D
PISTON ACTUATOR
LIMIT OF CONTRACT
u/g
DIAPHRAGM SEAL
TURBINE
MINI HYDRO
A
IPXX-X
MECHANICAL VIBRATOR
MOTOR
TWO WAY VALVE, FAIL OPEN
BALL VALVE
INST.
FE
XX
AUTOMATIC ACTUATOR WITH
POSITIONER
GATE VALVE
PIPING
M
TWO WAY VALVE, FAIL CLOSED
TERMINATION POINT
LOC
08. MOTORS AND DRIVES
BAR SCREEN
AUTOMATIC ACTUATOR
PIPE SPECIFICATION
CHANGE POINT
DICL
a/g
FE
XX
ULTRASONIC FLOWMETER
PROCESS LINE CROSSOVER
E
SUBMERSIBLE PUMP
C
BASKET STRAINER
FLUME
PRelV
XXXX
CONNECTION (OF LINES)
D
PRESSURE REGULATING
(EXTERNAL TAPPING)
EQUIPMENT NUMBER DISPLAY
DIRECTION OF FLOW / ARROW
PVCU
TURBINE OR PROPELLER METER
PRV
XXXX
CONE VALVE
RUPTURE DISK (OR BURSTING
DISC)
PRESSURE RELIEF
PSE
XXXX
VARIABLE AREA FLOW
INDICATOR
BACK PRESSURE REGULATING
SPRAY NOZZLE
LINE 1
LINE 2
AAXYZ-PPPP
B
PUMP CONTROL
HYDRAULIC SIGNAL
PROCESS FLOW CONTINUATION
FLAG - 3 LINES
IN LEFT / OUT RIGHT
ROTARY FINE SCREEN
POSITIVE DISPLACEMENT TYPE
FLOWMETER C/W FLOW
TOTALIZING INDICATOR
PRV
XXXX
SPACER
C
MAGNETIC FLOWMETER
FQI
XX
PUMP, ROTARY VANE
CAPILLARY TUBING
01. LABELLING
FE
XX
PRESSURE REGULATING
PRESSURE VACUUM VALVE
SPADE BLIND (OR SLIP BLIND)
INCLINED SCREEN (MOTOR
RAKED)
M
SPECTACLE BLIND,
NORMALLY OPEN
ELECTROMAGNETIC OR SONIC
SIGNAL
A
FE
XX
PUMP, HELICAL ROTOR
IN-LINE PRESSURE
RELIEF VALVE
SPECTACLE BLIND,
NORMALLY CLOSED
INCLINED SCREEN (MECH RAKED)
PUMP, CENTRIFUGAL
DOUBLE NON-RETURN CHECK
VALVE
UNDEFINED SIGNAL
12. SCREENING
PITOT TUBE OR ANNUBAR
NON-RETURN / CHECK VALVE /
REFLUX VALVE
STRAINER, GENERAL SYMBOL
12
GENERAL SYMBOL (UNSPECIFIED)
AIR PURGING DEVICE
TUNDISH / DRAIN
11
FE
XX
IN-LINE PRESSURE RELIEF
OR SAFETY VALVE
SHOWING PRESSURE SETTING
SYPHON DRAIN
INSTRUMENT SUPPLY OR
CONNECTION TO PROCESS
FO
X
PCV
XXXX
FLEXIBLE HOSE LINE
OPEN OR COVERED CONCRETE
CHANNEL
10
11. INSTRUMENT AND CONTROLS
PUMP, GENERAL SYMBOL
OVERFLOW (EG. TANK)
PROCESS LINE DOUBLE
CONTAINED
9
07. PUMPS
05. SELF ACTUATED
REGULATORS AND VALVES
PINCH VALVE
INSULATED / LAGGED
PROCESS LINE
8
D. Eager
AUTHORISED
DAM
RES
SPS
BWS
WAT
STP
WTP
SEW
WPS
REC
F
AERATOR
DRAWING STATUS
STANDARD DRAWING
PIPING AND INSTRUMENTATION DIAGRAM (P&ID)
DRAWING SYMBOLS
SHEET 1 OF 2
Current
SD-1100-D
ISSUE
A1
ASSET AREA APPLICABILITY
4
CADD File Name:C:\Temp\BC-WorkSpace\S_ESSERY\M-Seappsprd37,D-DrwWaterdbP\Masters\Standard_Drawing\1100\SD_1100_D.dwg
5
6
7
8
9
10
H
11
© Icon Water. 2017
12
A
1
2
3
14. FILTRATION
A
4
16. SLUDGE TREATMENT
5
6
7
20. GRIT AND OIL REMOVAL
18. CHLORINATION AND
DECHLORINATION
9
21. EQUIPMENT (MISC.) CONT.
10
22. STORAGE AND PRESSURE
VESSELS CONT.
EVAPORATOR
ACCUMULATOR OR
PULSATION DAMPENER
TRAVELING HOIST
FILTER BELT PRESS
Clâ‚‚
12
23. WATER AND SEWAGE
COMBINED FLUID CODES
1. REFER TO STD-SPE-M-002 FOR THE
APPLICATION OF WATER AND SEWAGE
TREATMENT FLUID CODES AS WELL AS VALVE
AND PIPING IDENTIFICATION CODES.
A
2. REFER TO WORK INSTRUCTION WI05.14.04
TITLED "ENGINEERING ASSET
IDENTIFICATION" FOR THE APPLICATION OF
ASSET LABELING AND EQUIPMENT
IDENTIFICATION CODES.
RAPID GRAVITY SAND FILTER
CHLORINATOR INCLUDING
INJECTOR
11
FIXED HOIST (HAND OPERATED)
MECHANICAL CLASSIFIER
FILTER PLATE PRESS
SAND FILTER (SHEET MEDIA)
8
GRIT CLASSIFIER (SCREW TYPE)
OVERHEAD CRANE
CENTRIFUGE (HORIZONTAL)
PRESSURE VESSEL
MEMBRANE FILTER MODULE
ELECTRICAL PLUG AND SOCKET
B
B
GAS CYLINDER
15. SEDIMENTATION TANKS,
THICKENERS AND CLARIFIERS
21. EQUIPMENT (MISC.)
CENTRIFUGE (BOWL TYPE)
ELECTROLYSER
24. INSTRUMENTATION & CONTROL
ELECTROLYSER
INSECT SCREENED VENT
VAC
17. SOLIDS HANDLING
CIRCULAR THICKENER
FLAT BOTTOM
SPRING
VACUUM REGULATOR
22. STORAGE AND PRESSURE
VESSELS
PRIMARY
FIELD
LOCATION
MOUNTED NORMALLY
ACCESSIBLE
TO
OPERATOR
SCRUBBER WITH DEMIST PAD
FIRE EXTINGUISHER
GAS DRUM
C
UV LAMP
CONVEYOR (BELT TYPE)
RECTANGULAR
THICKENER/SEDIMENTATION
TANK
STORAGE TANK
ODOUR ABSORPTION TOWER
WITH DEMIST PAD AND MEDIA
OR BIOTRICKLING FILTER
FIRE HOSE REEL
19. HEAT TRANSFER EQUIPMENT
HEAT EXCHANGER
HOSE COCK
INCLINED CONVEYOR (BELT
TYPE)
ELECTRIC HEATER
RECTANGULAR
GRIT SEPARATION TANK
D
DISCRETE
INSTRUMENTS
X
X
X
X
X
X
X
X
COMPUTER
FUNCTION
X
X
X
X
X
X
X
X
SHARED
DISPLAY
SHARED
CONTROL
X
X
X
X
X
X
X
X
PROGRAMMABLE
LOGIC CONTROL
(PLC)
X
X
X
X
X
X
X
X
C
SKIP BIN
CYCLONE SEPARATOR
CIRCULAR THICKENER
CONICAL BOTTOM
NORMALLY
NOT
LOCATION
ACCESSIBLE
NORMALLY
TO
ACCESSIBLE
OPERATOR
TO
OPERATOR (BEHIND
THE PANEL)
OPEN TANK
HYDRANT
D
FIRE HYDRANT
CONVEYOR (SCREW TYPE)
ADSORPTION COLUMN OR
TOWER
OIL BURNER
CLARIFIER WITH
PERIPHERAL LAUNDER
SCREW DOWN HYDRANT
OPEN TANK WITH COVER
INCLINED CONVEYOR (SCREW
TYPE)
GAS BURNER
DELUGE SHOWER
CLARIFIER WITH RADIAL
LAUNDER
HEATER
CONVEYOR (BUCKET TYPE)
SEALED TANK
EYE WASH
HORIZONTAL TANK
E
E
FLAME ARRESTOR
SAFETY SHOWER & EYE WASH
WEIGHING MACHINE
SCUM DRAW OFF
BOILER
WEIGHBRIDGE OR PLATFORM
WEIGHER
RAKE SCRAPER
CONTACT TANK
SILO (BASIC SYMBOL)
CARBOY/CONTAINER
CALIBRATION CYLINDER
COLLECTOR / HOPPER
FURNACE
SURFACE SKIMMER
INSPECTION HATCH /
MAINTENANCE HATCH
F
SIGHT LEVEL INDICATOR
DISINTEGRATOR/MACERATOR
SLUDGE ROLLER
F
ACCUMULATOR
BOTTLE/PULSATION
DAMPENER
AIR COOLED CONDENSER
SIGHT LEVEL INDICATOR WITH
GAUGE
FLIGHT SCRAPER
DOUBLE PIPE HEAT EXCHANGER
SCRAPER (GENERAL)
WHEELY BIN
PLATE HEAT EXCHANGER
G
SCRAPER (CHAIN & FLIGHT)
FIN TUBE HEAT EXCHANGER
G
AUTOMATIC SAMPLER
WATER SURFACE LEVEL
LAGOON
VAPOURISER
HORN
H
A
INITIAL ISSUE
15/06/2018
No.
ISSUE
1
Date Plotted: 25/06/2018
Plot Style: Water.ctb
DATE
2
Plotted by: Essery, Scott
C. Dickson
DRAWN
K. Danenbergsons
CHECKED
3
D. Eager
AUTHORISED
DAM
RES
SPS
BWS
WAT
STP
WTP
SEW
WPS
REC
DRAWING STATUS
STANDARD DRAWING
PIPING AND INSTRUMENTATION DIAGRAM (P&ID)
DRAWING SYMBOLS
SHEET 2 OF 2
Current
SD-1101-D
ISSUE
A1
ASSET AREA APPLICABILITY
4
CADD File Name:C:\Temp\BC-WorkSpace\S_ESSERY\M-Seappsprd37,D-DrwWaterdbP\Masters\Standard_Drawing\1100\SD_1101_D.dwg
5
6
7
8
9
10
H
11
© Icon Water. 2017
12
A
1
2
3
4
5
6
7
8
9
VALVES
WATER
10
11
12
OTHER FITTINGS
WATER
SEWER
WATER
SEWER
SEWER
A
A
AV
X
GATE VALVE
X
AIR VALVE - SINGLE
X
X
AIR GAP DEVICE
DEAD END
AIR VALVE - DOUBLE
X
X
AIR VESSEL
DISCHARGE POINT
AIR VALVE - ENHANCED DOUBLE
X
X
BLANK FLANGE
GAUGING POINT (ACTIVE)
BALL VALVE
X
X
DISMANTLING JOINT
GAUGING POINT (NON-ACTIVE)
DAV
X
ALTITUDE
ALT
EAV
FUNCTIONALITY
BAV
B
BACKUP ALTITUDE
X
KNIFE
X
X
*
M
M
MOTORISED
X
X
MOTORISED - NORMALLY
CLOSED
X
X
NORMALLY CLOSED
X
X
ALTITUDE
BACKUP ALTITUDE
BAV
END CAP
DOUBLE CHECK VALVE
X
FLOW ELEMENT
MAINTENANCE HOLE
FLOAT OPERATED VALVE
X
FLOW METER OR RECORDING DEVICE
REDUCER
DCV
FUNCTIONALITY
FRCV
D
FAV
M
PLUG
FLOW RATE ALTITUDE
COMBINATION
X
GIBAULT JOINT
PLUG VALVE
X
MOTORISED - NORMALLY
CLOSED
*
X
M
X
P
STOP OR SCOUR VALVE (NORMALLY
CLOSED ON SCOUR OR DRAIN PIPE)
X
TEMPORARY ZONE VALVE
X
X
S
HYDRANT - MILCOCK
STORAGE TANK (BURIED) OR
SEWAGE OVERFLOW STRUCTURE
OVERHEAD FILLING POINT
STORAGE TANK (NOT BURIED)
INLINE VALVE - TONGUE REMOVED
E
PCV
X
FUNCTIONALITY
FAV
FRCV
OCV
PRV
FLOW RATE ALTITUDE
COMBINATION
X
FLOW RATE CONTROL
X
OUTLET CONTROL
X
PRESSURE REDUCING
X
VERTICAL DROP
VORTEX DROP
E
WEIR
REDUCER / TAPER
VERTICAL RISER
PUMP, PUMP STATION
TEE
SAMPLING POINT
F
TEE / OPEN END
STOPCOCK
THRUST BLOCK
SEWER
TRENCH / SCOUR
NOTES:
BURIED VERTICAL RISER (BVR)
G
1. ALL SYMBOLS SHALL BE SHOWN IN BLACK UNLESS PRESENTED OTHERWISE.
SERVICE POINT
2. REFER TO DRAWING SD-1103 FOR LINETYPES.
SLOPE JUNCTION
X
CONE VALVE
VENT (INDUCT)
MAIN COCK
X
PUMP CONTROL
PCV
W
SP
X
PRESSURE SUSTAINING
PSV
REDUCED PRESSURE ZONE DEVICE
(RPZD)
VENT (EDUCT)
BILLING METER LARGE(≥40mm)
BVR
G
V
D
BILLING METER SMALL(<40mm)
X
BACKUP ALTITUDE
F
WATER
X
ALTITUDE
BAV
PRESSURE GAUGE OR RECORDING
DEVICE
X
GLOBE VALVE
ALT
SVD
X
PUMP CONTROL
SVE
SVI
MAINTENANCE HOLE
SERVICE CONNECTION FITTINGS
SPECIAL INSPECTION SHAFT
HYDRANT - SPRING
ORIFICE PLATE
NORMALLY CLOSED
SCREEN
SIS
HYDRANT - PILLAR
OH
X
STOP LOG
SCOUR
X
X
SL
X
RODDING POINT
C
X
PENSTOCK VALVE
PRESSURE RELIEF VALVE
MOTORISED
M
X
X
FLOW RATE CONTROL
FRCV
P
RP
X
NEEDLE VALVE
X
DUAL FLOW RATE
CONTROL
INSPECTION SHAFT (STANDARD
225mm)
X
C
ALT
SMS
ZONE VALVE
X
BUTTERFLY VALVE
B
3. SYMBOLS SIZED FOR LEGIBILITY WHEN PRINTED AT A3 SIZE.
4. VALVE AND FITTINGS NORMALLY OPEN UNLESS NOTED OTHERWISE.
FUNCT.
X
ALTITUDE
ALT
H
DAM
RES
SPS
BWS
WAT
STP
A
INITIAL ISSUE
15/06/2018
S. Essery
K. Danenbergsons
D. Eager
WTP
SEW
B
DISTRICT METER ZONE VALVE CHANGED TO ZONE VALVE
18/06/2019
S. Essery
K. Danenbergsons
C. Patrick
WPS
REC
No.
ISSUE
1
Date Plotted: 2/07/2019
Plot Style: Water.ctb
DATE
2
Plotted by: Essery, Scott
DRAWN
CHECKED
3
AUTHORISED
DRAWING STATUS
STANDARD DRAWING
BULK WATER, WATER & SEWERAGE
DESIGN SYMBOLS FOR PLANS AND TIE BOOKS
Current
SD-1102-D
ISSUE
A1
ASSET AREA APPLICABILITY
4
CADD File Name:C:\Temp\BC-WorkSpace\S_ESSERY\M-Seappsprd37,D-DrwWaterdbP\Projects\CX10999\Standard_Drawing\1100\SD_1102_D.dwg
5
6
H
7
8
9
10
11
© Icon Water. 2017
12
B
1
2
3
4
5
6
7
8
TABLE 1: LINETYPES FOR THE PRODUCTION OF KEY PLANS, HYDRAULIC PLANS AND SERVICE PLANS
A
LINE TYPE
SERVICE TYPE
eW
WATER MAIN/LINE (REF. NOTE 1)
eS
GRAVITY SEWER MAIN
SRM
EXISTING ASSETS WATER OR SEWER
7
0.25
W
W
LINETYPE
HYDRAULIC PLANS
W
BULK WATER MAIN
W
W
W
PROPOSED OR NEW
ASSETS - WATER
NETWORK
WATER DISTRIBUTION MAIN
175
WATER RETICULATION MAIN
145
WATER RISING MAIN
145
WATER NETWORK - DRAIN LINE
235
WATER NETWORK - OVERFLOW LINE
75
C
0.70
WATER NETWORK - DOMESTIC SERVICE
LINE
WATER NETWORK - FIRE SERVICE LINE
S
S
D
S
PROPOSED OR NEW
ASSETS - SEWERAGE
NETWORK
SRM
135
0.70
235
BVR
X
TELECOMMUNICATIONS (e.g. TELSTRA)
X
0.25
X
ABANDONED
85
STORMWATER MAIN (STW)
NOTES:
232
252
1.50
206
1.00
1.
WATER MAINS/LINES ARE DEFINED AS: BULK SUPPLY MAINS, DISTRIBUTION MAINS, RETICULATION MAINS, RISING MAINS, DRAIN LINES,
OVERFLOW LINES, SCOUR LINES, WASHDOWN LINES, DOMESTIC SERVICE LINES AND FIRE SERVICE LINES, ALL OF WHICH HAVE THE
INTENDED PURPOSE OF CONVEYING BULK OR POTABLE WATER.
2.
A MAIN/LINE TO BE DECOMMISSIONED, WHETHER IT BE FOR WATER OR SEWERAGE, SHALL BE ANNOTATED TO SHOW THE TYPE OF
DECOMMISSIONING. FOR EXAMPLE, DESCRIPTORS SUCH AS "ABANDONED" , "EXHUMED" , "DECOMMISSIONED AND END CAPPED" SHALL BE
CLEARLY SHOWN ON THE RELEVANT PLANS. THIS WILL ALLOW ICON WATER TO BETTER DETERMINE WHETHER A DECOMMISSIONED LINE
CAN BE REINSTATED FOR USE AT A LATER DATE.
F
STORMWATER (REF. NOTE 3)
612.220
675 x
28.3 m
0.46 %
612.090
LENGTH (m)
DEPTH (m)
SIZE (mm)
MATERIAL
PIPE MATERIALS
G
0.70
GAS MAIN (GAS)
G
PROPOSED OR NEW
ASSETS
SEWER TIE
TIE
TIE
TIE
TIE
4
EFFLUENT REUSE MAIN (EFF)
ELECTRICITY (ELC)
TABLE 2: HYDRAULIC INFORMATION BOXES
SEWER
T 1.0
D 0.0
S 100
M uPVC
D
E
WATER ZONE BOUNDARY
UPSTREAM INVERT LEVEL
PIPE DIAMETER & MATERIAL
PIPE LENGTH (m)
PIPE GRADE
DOWNSTREAM INVERT LEVEL
ABANDONED
232
OTHER
612.220
150 PE
28.3 m
0.46 %
612.090
X
SW
SEWER TIE (WITH BVR CONNECTED TO
MAINS)
SEWER MAIN
0.50
TELECOMMUNICATIONS (e.g. TELSTRA)
232
STAGE BOUNDARY
F
0.50
STORMWATER MAIN (STW)
SW
0.70
65
SEWER TIE (CONNECTED TO MAINS)
E
3
C
GAS MAIN (GAS)
G
245
SEWER NETWORK - TIE OR
PROPERTY SERVICE LINE
LINE COLOUR LINE THICKNESS (mm)
SERVICE TYPE
ELECTRICITY (ELC)
145
SEWER SCOUR MAIN
B
174
EFFLUENT REUSE MAIN (EFF)
ERM
ERM
SEWER RISING MAIN
84
215
245
SEWER SYPHON MAIN
STORMWATER MAIN, MANHOLE AND
SUMP (REF. NOTE 3)
WATER MAIN
245
SEWER GRAVITY MAIN - TUNNEL
0.50
SPRINKLER SERVICE
LINETYPE
245
SEWER GRAVITY MAIN - TRUNK
14
SS
TABLE 4: LINETYPES FOR THE PRODUCTION OF KEY PLANS, HYDRAULIC PLANS & SERVICE PLANS OTHER UTILITIES (NOTE 3)
EXISTING ASSETS
SEWER GRAVITY MAIN - RETIC
SEWER MAIN, MANHOLE AND JUNCTION
FIRE SERVICE
SW
45
WATER NETWORK - WASHDOWN LINE
0.50
FS
S
TIE BOOKS
3
DOMESTIC WATER SERVICE
W
WATER NETWORK - SCOUR LINE
12
LINE COLOUR LINE THICKNESS (mm)
SERVICE TYPE
W
S
35
11
A
SEWER SCOUR MAIN, SEWER TIE OR
PROPERTY SERVICE LINE
MAIN/LINE TO BE DECOMMISSIONED SEWER OR WATER (REF. NOTE 2)
eS
10
TABLE 3: LINETYPES FOR THE PRODUCTION OF DRAINAGE PLANS & TIE BOOKS
SEWER RISING MAIN
eS
B
LINE COLOUR
LINE THICKNESS (mm)
9
UPSTREAM INVERT LEVEL
PIPE DIAMETER / MATERIAL
PIPE LENGTH (m)
PIPE GRADE
DOWNSTREAM INVERT LEVEL
LINE THICKNESS
PIPE SPECIFICATION CHANGE POINT
3.
UTILITIES NOT OWNED/OPERATED BY ICON WATER SHALL BE SHOWN IN ACCORDANCE WITH THE RELEVANT AGENCY/UTILITY'S DRAFTING
STANDARDS ON THE CONDITION THAT EXISTING AND NEW/PROPOSED LINES ARE SHOWN IN COLOUR "0" (BLACK) WITH THE EXCEPTION
OF STORMWATER. ICON WATER AND TRANSPORT CANBERRA AND COMMUNITY SERVICES (TCCS) HAVE AGREED THAT STORMWATER LINES
(BOTH EXISTING AND PROPOSED) SHALL BE SHOWN IN ACCORDANCE WITH TCCS DRAFTING REQUIREMENTS (i.e. BLACK FOR EXISTING AND
GREEN FOR NEW/PROPOSED). IF THE RELEVANT AGENCY/UTILITY DOES NOT HAVE A DEFINED DRAFTING STANDARD THEN THE ICON
WATER PREFERRED LINETYPES SHOWN IN TABLE 4 SHALL BE APPLIED.
4.
REFER TO DRAWING SD-1102 FOR THE DESIGN SYMBOLS TO BE USED.
5.
THE LINE COLOURS INDICATED IN TABLES 1 TO 4 ABOVE REFER TO COLOUR NUMBERS FROM THE STANDARD AUTOCAD COLOUR PALETTE.
THE LINEWEIGHTS INDICATED ARE FOR PRINTING AT A1 SIZE. WHEN PRINTING AT A3 SIZE, HALFWIDTHS SHALL BE USED.
G
0.25mm
LIMIT OF CONTRACT
L OF C
L OF C
H
DAM
RES
SPS
BWS
WAT
STP
A
INITIAL ISSUE
15/06/2018
M. Matusiak
K. Danenbergsons
D. Eager
WTP
SEW
B
SEWER TIE INFORMATION BOX AND LINE TYPES UPDATED
18/06/2019
S. Essery
K. Danenbergsons
C. Patrick
WPS
REC
No.
ISSUE
1
Date Plotted: 2/07/2019
Plot Style: Water.ctb
DATE
2
Plotted by: Essery, Scott
DRAWN
CHECKED
3
AUTHORISED
DRAWING STATUS
STANDARD DRAWING
BULK WATER, WATER & SEWERAGE
LINETYPES AND NOTATION
FOR PLANS AND TIE BOOKS
Current
SD-1103-D
ISSUE
A1
ASSET AREA APPLICABILITY
4
CADD File Name:C:\Temp\BC-WorkSpace\S_ESSERY\M-Seappsprd37,D-DrwWaterdbP\Projects\CX10999\Standard_Drawing\1100\SD_1103_D.dwg
5
6
7
8
9
10
H
11
© Icon Water. 2017
12
B
1
2
3
4
5
6
7
8
9
10
11
12
NOTES:
LEGEND WITH ALL
RELEVANT LINE TYPES
AND SYMBOLS SHOWN
A
3
4
5
6
7
560
8
9
10
2.
eS
LEGEND
EXISTING WATER MAIN
PRESSURE ZONE BOUNDARY
ZONE VALVE. REFER DETAIL 3
W
EXISTING SEWER MAIN
NEW WATER MAIN
NEW WATER PROPERTY SERVICE LINE
FROM CONNIE RESERVOIR
STAGE CONNECTION
SEE DETAIL 1
PRESSURE ZONE BOUNDARY
SVD
98
1
11
9
2
3
4
1
3
5
7
6
5
75
9
8
7
5
7
9
3
1
12
11
10
10
8
6
14
12
16
eS
2
1
10
12
14
4
5
7
3
6
2
15
14
13
12
9
11
15
5
7
13
3
H
*
T
N
E
15
14
16
14
12
10
8
C
16
14
eS
20
19
18
16
21
17
22
7
9
11
15
17
5
13
3
7
13
8
6
5
12
6
7
G
F
STAGE CONNECTION DETAIL
E
PAUL PAR
SUPER HIGH PRESURE ZONE
2
SVD
4
14
70
13
68
12
32
4
6
5
8
6
10
64
10
E
FL-SOC
THRUST WALL
*
F
H
FL-SOC
12
65
STOP VALVE, OPEN
16
8
40
80
120
DETAIL 3
8
14
0
ZONE VALVE, CLOSED
THRUST WALL
7
11
FL-FL PIPE SPACER
FL-FL PIPE
SPACER
9
67
66
HIGH PRESURE ZONE
HYDRANT AND TEE
FL-FL SPOOL PIPE
2
3
15
72
BAILEY'S RESIDENTIAL ESTATE
STAGE 1 - SUB STAGE 1A
SEWER AND WATER KEY PLAN
D
eS
eS
5
69
eS
6
7
12
71
CONNECTION DETAILS
(NOTE 3)
DETAIL 2
31
1
46
eS
eS
13
4
74
eW
10
150∅ DICL
W
STAGE 1A
eW
12
8
6
5
7
15
47
7
6
12
3
73
C
150 x 150 TEE
23
1
76
2
DETAILS OF ALL CONNECTION POINTS ARE TO BE
SHOWN ON THE HYDRAULIC CONNECTIONS PLAN. IF
ADDITIONAL SPACE IS REQUIRED, A DEDICATED
CONNECTION DETAILS DRAWING IS TO BE
PROVIDED AS THE NEXT DRAWING IN THE SET.
eW
13
16
9
5
14
14
11
4
15
10
9
5
13
3
16
12
11
48
76
8
eS
1
1
16
15
eS
eS
14
13
4
14
78
1
2
4
STAGE 1C
2
1
16
15
3
15
80
7
11
eW
eW
CONNECTION
LOCATIONS SHOWN AND
REFERENCED ON PLANS
4
3
2
24
12
6
D
SV
D
SV
D
SV
eS
S
2
1
82
PAUL PARADE
D
SV
CONNECT TO EXISTING
SEWER MAINTENANCE
HOLE
16
84
F
13
5
6
eW
SVD
eS
86
18
20
22
E
*
eS
C
S
E
R
C
A
LI
S
T
eS
A
20
21
17
16
33
49
18
14
STAGE 1B
STAGE 1D
19
12
eW
E
eW
10
B
eW
STAGE CONNECTION
SEE DETAIL 1
5
4
3
2
1
10
9
8
7
8
6
4
1
6
D
eW
92
eS
A PLAN VIEW OF THE FULL EXTENT OF THE
CONNECTION AREA.
ALL ADJOINING (INCLUDING FUTURE) STAGES /
ICON WATER ASSETS TO THE CONNECTION AREA.
LOCATION OF ALL ZONE VALVES, PRV'S, HYDRANTS
AND SLUICE VALVES.
PRESSURE ZONES, WITH CLEAR BOUNDARIES AND
LABELS STATING PRESSURE DETAILS.
ALL CONNECTION DETAILS, WITH REFERENCE TO
THE RELEVANT CONNECTION DETAIL AND
DRAWING NUMBER (IF APPLICABLE).
LEGEND WITH ALL RELEVANT LINE TYPES AND
SYMBOLS.
eW
H
PRESSURE ZONE
BOUNDARIES
SHOWN
REMOVE BLANK FLANGE
BY ICON WATER AT
CONTRACTORS EXPENSE.
16
E
McRAE PLAC
2
9
11
13
15
17
8
17
1
3
5
7
16
18
C
eS
S T R E E T
SVD
SVD
3.
SVD
34
SVD
E S S E R Y
SVD
8
2
4
STAGE CONNECTION DETAIL
SEWER VERTICAL DROP
11
6
1
15
DETAIL 1
SEWER MAINTENANCE HOLE
6
4
8
9
·
·
ZONE VALVE
NABIN ROAD
19
13
*
W
10
11
*
50
14
WATER FIRE HYDRANT
5
150∅ DICL
P A R K W A Y
S T R E E T
M A T T H E W
7
2
4
6
4
35
P A R K W A Y
SUPER HIGH
PRESSURE ZONE
TWL 685.0
8
3
WATER STOP VALVE
B
WATER REDUCER
eW
SVD
10
W
eS
12
D A N E N B E R G S O N S
10
8
5
6
7
9
2
(EXISTING)
eW
eW
51
81
77
eW
4
3
2
1
1
(NEW)
79
eS
10
D A N E N B E R G S O N S
W
0
11
8
6
10
4
10
HIGH PRESSURE
ZONE
TWL 640.0
·
150∅ DICL
83
D
·
W
eW
D
·
NEW SEWER MAIN / PROPERTY SERVICE LINE
B
C
·
3
eS
W
A
A
DISCONNECT AND REMOVE END CAP AND
THRUST BLOCK. CONNECT NEW 150∅
WATER MAIN. CONNECTION BY ICON
WATER AT CONTRACTORS EXPENSE
STAGE BOUNDARY
ARRANGEMENTS AND DETAILS OF SERVICES,
THRUST RESTRAINTS AND EQUIPMENT DEPICTED IN
THIS DRAWING ARE EXAMPLES ONLY. THIS
DRAWING IS NOT TO BE USED AS A GUIDE TO
WATER AND SEWER PIPE AND EQUIPMENT
LAYOUTS.
A HYDRAULIC CONNECTIONS DRAWING MUST
CONTAIN THE FOLLOWING DETAILS:
W
B
C
12
52
A
PRESSURE ZONE
INFORMATION
SHOWN
11
W
150∅ DICL
2
eS
1
1.
160
30
PRESSURE ZONE BOUNDARY ZONE VALVE
200m
G
F
SCALE 1:2000
SCALE 1:2000 @ A1
Issued For Construction
Drawn:
Designed:
H
A
KEIRAN
BAILEY'S RESIDENTIAL ESTATE
STAGE 1D
HYDRAULIC CONNECTIONS
PLAN
C. Allen
26/06/2019
INITIAL ISSUE
No.
DATE
REVISION
1
G
Scale:
I. McDonell
2
ENG CHECKED
3
VERIFIED
DESIGN AUTH
4
5
6
7
8
9
Date:
Sheet No.:
30/01/2018
Project No.:
Tender No.:
CX10999
ACT Cadastral information supplied by the ACT Environment
& Sustainable Development Directorate. © ACT Gov. 2016.
Rev
2019/00112
10
11
H
TITLE BLOCK TO BE PREPARED IN
ACCORDANCE WITH ICON WATER
DRAFTING STANDARDS
12
Water.ctb
H
A
INITIAL ISSUE
26/06/2019
No.
ISSUE
1
Date Plotted: 3/07/2019
Plot Style: Water.ctb
DATE
2
Plotted by: Essery, Scott
S. Essery
DRAWN
K. Danenbergsons
CHECKED
3
C. Patrick
AUTHORISED
ALL INFORMATION SHOWN ON
THIS DRAWING MUST BE CLEAR
WHEN PRINTED AT A3
SCALE BAR TO BE SHOWN
STAGE LABEL
DAM
RES
SPS
BWS
WAT
STP
WTP
SEW
WPS
REC
DRAWING STATUS
STANDARD DRAWING
WATER AND SEWER NETWORK
HYDRAULIC CONNECTIONS DRAWING
DRAWING EXAMPLE AND REQUIREMENTS
Current
4
5
6
7
8
9
10
H
SD-1104-C
A1
ASSET AREA APPLICABILITY
CADD File Name:C:\Temp\BC-WorkSpace\S_ESSERY\M-Seappsprd37,D-DrwWaterdbP\Projects\CX10999\Standard_Drawing\1100\SD_1104_C.dwg
G
11
ISSUE
© Icon Water. 2017
12
A
Download