6.4.1 Electrical Connections Electrical Circuit Diagram #6 Spea ker B5 J6 #5 B2 #7 #8 B3 M1 #8 #9 Configuration of 8.4" display LN J5 #11 M3 M3 J8 #52 #12 I2C /PCON/AC J4 #13 5V/12V #14 16.8V J5 J4 #29 J1-4 J2 B23 Connected to #57 #16 J3 J2 J3-12 J1-2 Fan J3 J14 #56 J2-1 J2-2 B24 J2-3 #55 #40 J2-4 #55 #58 J8 J9 #11 #23 J10 J17 #37 #11 B13 J3 J15 J1-1 #37 J3 16.8V J5 J2 J1 J7 #45 #15 J4 #15 J8 #15 #23 J2 #50 B21 B22 B10/B11/B12 #24 P1 J6 #15 B14 J1-2 J14 J7 #49 #46 #47 B17 B18 #48 Parallel 3 electrical outlets #32//#4//#43//#44 External CO2 module Configuration when there is no isolation transformer. #1 509B-1006192 B9 5V/12V 风扇 Parallel 3 fuses AC socket #22 #13 B16 Connected to ● 509B-1006192 M2 #21 J4 J6 #2 ● AC socket J1 #19 J16 J14 J1-1 J9-1 J10 #57 #41 J3 5B/12V and serial port J7 Temperature Sensor LVDS #18 #3 J2 B7 J1 J9-2 #29 12V B6 #17 AC/PCON J1 Circuit switch J2 B1 J2 风扇 J3 J4 #3 J5 Configuration of 7" display B4 #10 B8 M4 J7 Connected to N #36 J4 J1 #31 Parallel 3 fuses #32 #4 #43 #44 #35 #35 J2 J3 J5 #33 C o n n e c t e d t o J3-2 J3-3 J3-4 J11 J3-7 Parallel 3 electrical outlets B15 Isolation transformer J3-1 L #2 #53 #16 Conne cted to #25 #26 Conne cted to Conne cted to #27 #16 #16 Conne cted to #29 J3-5 J3-6 #16 Conne cted to #29 J3-8 #16 Conne cted to #30 #34 J3-12 J3-13 #16 Ship-shaped switch System switch Circuit switch Bag/mechanical ventilation switch Conne cted to #28 Conne cted to #16 #42 #16 Conne cted to #42 Conne cted to #42 #39 O2 sensor O2 pressure switch of gas supply inlet assembly Inspiratory valve PEEP valve Safe valve Wiring S/N P/N Description 1 009-000057-00 AC power cable (with isolation transformer) 2 009-000058-00 AC power cable for the power board 3 9201-30-35926 Power cable for the lithium battery 6-57 #54 ACGO limit switch and pneumatic block pressure switch Conne cted to #16 B19 B20 Three-way-valve #29 J3-9 J1 J1 BYPASS #51 Conne cted to J3-10 Configuration when there is isolation transformer. #16 #16 #38 Tempe rature switch Fan #16 S/N P/N Description 4 0621-20-69609 European standard socket connection line 5 009-000070-00 Inverter drive line 6 009-000071-00 12V power cable for the 7" display conversion board 7 8000-21-10239 Connection line for the TFT display backlight board 8 009-000045-00 Drive line for the keypad scanning board 9 9200-21-10460 Encoder connection line 10 9200-21-10633 2.25" speaker and connection line 11 009-000046-00 Power cable for the keypad board etc. 12 009-000047-00 Power board control communication cable 13 009-000048-00 5V/12V power cable 14 009-000049-00 16.8V power cable 15 009-000044-00 Monitor board connection line 16 009-000072-00 Power signal connection line 17 009-000050-00 Keypad board communication cable 18 009-000069-00 8" TFT display data line 19 009-000073-00 7" display LVDS data line 21 009-000199-00 FPC 7" display LVTTL data line 22 009-000051-00 Internal network cable 23 009-000052-00 CO2 connection line for flow calibration 24 009-000053-00 CO2 module external cable 25 009-000059-00 Flowmeter backlight connection line 26 009-000060-00 Table toplight connection line 27 0621-20-69494 System switch connection line B 28 0601-21-78956 Connection line for the circuit internal O2 sensor 29 0621-20-78593 Connection line for the circuit internal switch 30 0621-20-69588 Connection line for the flowmeter inlet pressure switch 31 0621-20-69606 Power cable for the auxiliary output 32 0621-20-69608 National standard socket connection line 33 009-000062-00 Connection line for fan and temperature switch 34 0611-20-58667 Transformer cooling fan and connection line 35 TSB1-20-20394 Isolation transformer 36 009-000063-00 AC power cable B for the isolation transformer 37 009-000100-00 Communication cable between the main control board and monitor board 38 0621-20-78594 Isolation transformer temperature switch line 39 0601-20-78941 Connection line for the circuit external O2 sensor 40 009-000368-00 0616 AC power cable 41 009-000074-00 7" display backlight drive line 42 009-000066-00 Connection line for NORGREN pneumatic block 43 009-000067-00 American standard socket connection line 6-58 S/N P/N Description 44 009-000068-00 British and Indian standard socket connection line 45 009-000198-00 Circuit switch/bypass line 46 009-000054-00 CO2 module internal power supply and communication cable 47 009-000055-00 Connection line between the CO2 module and the LED indicator on the front panel 48 6200-21-11608 Fan connection line 49 M02A-20-25934 Watertrap connection line 50 009-000056-00 Connection line between the calibration power interface board and VT 51 009-0000061-00 Connection line for the three-way valve assembly 52 8002-20-36195 Fan and connection line 53 009-000076-00 Connection line between the breaker and power board 54 009-000075-00 Table toplight switch line B1 051-000117-00 Power board PCBA B2 0000-10-11020 Inverter B3 051-000045-00 8.4" display keypad scanning board B4 051-000044-00 7" display keypad scanning board B5 0010-30-43089 Copper axis encoder board B6 051-000043-00 Keypad board B7 051-000041-00 or 051-000138-00 0616 7" display conversion board PCBA B8 051-000042-00 Power signal conversion board B9 0621-30-78696 Main control board B10 0621-30-78632 Signal detection board B11 0621-30-78634 Valve drive board B12 0621-30-78636 Auxiliary monitor board B13 9210-30-30152 Network conversion board B14 051-000046-00 Calibration power interface board B15 051-000036-00 Drive board for the isolation transformer B16 051-000047-00 CO2 module signal conversion board B17 M02B-30-64513 CO2 module main unit B18 6200-20-11585 Indicator board B19 051-000040-00 Flowmeter backlight board B20 0621-30-69356 Table toplight board B21 \ VT B22 \ CO2 watertrap M1 0000-10-10772 LCD TFT 8.4" 800*600 3.3V M2 0000-10-11182 or 021-000007-00 LCD TFT 7.0" 800*480 LED M3 M05-010001-06 Li-ion 11.1V4400mAhLI23S001A M4 M07-00086S--- SWITCH breaker 250V 7.5A welded terminal 6-59 6.4.2 Pneumatic Connections 6.4.2.1 Pneumatic Connection A: Module Pneumatic Connections Connection Diagram 6-60 Tubing 0616 tube No. reference table (module pneumatic diagram) Tube No. Length(m m) DiameterФ(m m) P/N Remark 1 1100 Tube 5.6*2.4 A21-000007--- / 2 800 Tube 5.6*2.4 A21-000007--- / 3 1080 Tube 5.6*2.4 A21-000007--- / 4 315 Tube 5.6*2.4 A21-000007--- / 5 270 Tube 5.6*2.4 A21-000007--- / 6 255 Tube 5.6*2.4 A21-000007--- / 7 190 Tube 5.6*2.4 A21-000007--- / 10 80 Tube 5.6*2.4 A21-000007--- / 12 80 Tube 5.6*2.4 A21-000007--- / 14 80 Tube 5.6*2.4 A21-000007--- / 16 125 Tube 5.6*2.4 A21-000007--- / 11 590 PU tube 4*2.5 M6G-020046--- / 13 550 PU tube 4*2.5 M6G-020046--- / 15 550 PU tube 4*2.5 M6G-020046--- / 17 550 PU tube 4*2.5 M6G-020046--- / 90 Silicone tube 25*20 18 / M6G-020018--- 21 225/60 PU tube 10*7 082-000519-00 The length is 60mm when separate ACGO is configured. 22 225/150 PU tube 10*7 082-000519-00 The length is 150mm when ACGO is not configured. 23 240 Silicone tube 25*20 M6G-020018--- 82 65 Tube 5.6*2.4 A21-000007--- 125 Silicone tube 25*20 27 28 29 100 80 PU tube 10*7 MPF tube 2*3.5 / / / M6G-020018--082-000519-00 Only available when separate ACGO is configured. M6G-020005--- Only available when AG module is configured. Select the following tubes when ACGO straight connector (with ACGO pressure monitoring) is configured 94 150 Tube 5.6*2.4 A21-000007--- / 95 230 Tube 5.6*2.4 A21-000007--- / 97 750 PU tube 4*2.5 M6G-020046--- / 6-61 Notes: 1. When a tube whose length is ≥300mm is selected, the tolerance requirement is ±10mm. When a tube whose length is ≤300mm is selected, the tolerance requirement is ±5mm. 2. Y1 indicates connector: StraightReduction,1/8"&3/32"ID,P/N:M90-100027--3. Y2 indicates connector: Tube to Tube right angle connector 3102-10-00,P/N:M6Q-030082--4. Y3 indicates connector: connector.Y,200Barb,1/8"ID,White Nylon,P/N:M90-100030--- 6-62 6.4.2.2 Pneumatic Connection B: Pneumatic Connections (O2, N2O and Air supplies, gas cylinders, O2 drive gas) Connection Diagram 6-63 Tubing 0616 tube No. reference table (configured with O2, N2O and Air supplies, cylinders, and O2 as the drive gas) Tube No. Length (mm) DiameterФ(mm) P/N Remark 25 600 PU tube 8*5.5 M6G-020045--- / 39 510/380 PU tube 4*2.5 M6G-020046--- The length is 510mm for European standard and 380mm for American standard/American European standard. 40 420 PU tube 4*2.5 M6G-020046--- / 41 440/570 PU tube 4*2.5 M6G-020046--- The length is 440mm for European standard and 570mm for American standard/American European standard. 42 120/60 PU tube 6*4 M6G-020026--- The length is 60mm when auxiliary O2 supply assembly is configured. 43 160 PU tube 6*4 M6G-020026--- / 44 620 PU tube 6*4 M6G-020026--- / 45 200 PU tube 6*4 M6G-020026--- / 46 110 PU tube 6*4 M6G-020026--- / 47 210 PU tube 6*4 M6G-020026--- / 48 300 PU tube 4*2.5 M6G-020046--- / 49 280 PU tube 4*2.5 M6G-020046--- / 50 280 PU tube 6*4 M6G-020026--- / 51 280 PU tube 6*4 M6G-020026--- / 52 250/75 PU tube 6*4 M6G-020026--- The length is 75mm when ACGO is not configured. 53 630 PU tube 8*5.5 M6G-020045--- / 54 280 PU tube 8*5.5 M6G-020045--- / 55 460 PU tube 6*4 M6G-020026--- / 56 60 PU tube 6*4 M6G-020026--- Only available when auxiliary O2 supply is configured. 57 380 PU tube 6*4 M6G-020026--- Only available when auxiliary O2 supply is configured. 58 200 PU tube 8*5.5 M6G-020045--- / 60 150 PU tube 8*5.5 M6G-020045--- / 62 120 PU tube 8*5.5 M6G-020045--- / 63 70 PU tube 8*5.5 M6G-020045--- / 64 70 PU tube 8*5.5 M6G-020045--- / 65 100 PU tube 8*5.5 M6G-020045--- / 6-64 Select the following tubes when O2 and Air cylinders are configured 68 280 PU tube 8*5.5 M6G-020045--- / 69 100 PU tube 8*5.5 M6G-020045--- / M6G-020045--- The length is 300mm for European standard and 230mm for American standard/American European standard. M6G-020045--- The length is 125mm for European standard and 240mm for American standard/American European standard. 85 88 300/230 125/240 PU tube 8*5.5 PU tube 8*5.5 Select the following tubes when O2 and N2O cylinders are configured 82 300 PU tube 8*5.5 M6G-020045--- / 83 100 PU tube 8*5.5 M6G-020045--- / M6G-020045--- The length is 270mm for European standard and 370mm for American standard/American European standard. M6G-020045--- The length is 300mm for European standard and 230mm for American standard/American European standard. 84 85 270/370 300/230 PU tube 8*5.5 PU tube 8*5.5 Select the following tubes when only one O2 cylinder is configured 85 300/230 PU tube 8*5.5 M6G-020045--- The length is 300mm for European standard and 230mm for American standard/American European standard. Select the following tubes when two O2 cylinders are configured 85 80 PU tube 8*5.5 M6G-020045--- / 86 135 PU tube 8*5.5 M6G-020045--- / 87 205 PU tube 8*5.5 M6G-020045--- / 6-65 Notes: 1. When N2O cylinder is not configured, connect the N2O supply inlet assembly directly to the pressure regulator assembly. The tubes used and their Nos. are same to those in Appendix 2 (tube No.: 61#, tube length: 460±10mm, diameter: 8*5.5). 2. When Air cylinder is not configured, connect the Air supply inlet assembly directly to the pressure regulator assembly. The tubes used and their Nos. are same to those in Appendix 2 (tube No.: 66#, tube length: 380±10mm, diameter: 8*5.5). 3. When only one O2 cylinder is configured, insert tube 85# directly into the connector of O2 cylinder yoke 1. 4. A indicates connector: Tube to Tube Y piece 3140-06-00,P/N:M6Q-030024---, indicated by A1 and A2 in the diagram. 5. B indicates connector: Tube to Tube Y piece 3140-08-00,P/N:M6Q-030025--, indicated by B1 and B2 in the diagram (P/N of B3 is 082-000448-00). 6. C and C2 indicate connector: different diameter Tube to Tube, straight connector, 3106-06-08,P/N:M6Q-030051--- 6-66 6.4.2.3 Pneumatic Connection C: Pneumatic Connections (O2, N2O and Air supplies, gas cylinders, Air drive gas) Connection Diagram 6-67 Tubing 0616 tube No. reference table (configured with O2, N2O and Air supplies, cylinders, and Air as the drive gas) Tube No. Length (mm) DiameterФ(mm) P/N Remark 25 600 PU tube 8*5.5 M6G-020045--- / 39 510/380 PU tube 4*2.5 M6G-020046--- The length is 510mm for European standard and 380mm for American standard/American European standard. 40 420 PU tube 4*2.5 M6G-020046--- / 41 440/570 PU tube 4*2.5 M6G-020046--- The length is 440mm for European standard and 570mm for American standard/American European standard. 42 120/60 PU tube 6*4 M6G-020026--- The length is 60mm when auxiliary O2 supply assembly is configured. 43 160 PU tube 6*4 M6G-020026--- / 44 620 PU tube 6*4 M6G-020026--- / 45 200 PU tube 6*4 M6G-020026--- / 46 110 PU tube 6*4 M6G-020026--- / 47 210 PU tube 6*4 M6G-020026--- / 48 300 PU tube 4*2.5 M6G-020046--- / 49 280 PU tube 4*2.5 M6G-020046--- / 50 280 PU tube 6*4 M6G-020026--- / 51 280 PU tube 6*4 M6G-020026--- / 52 250/75 PU tube 6*4 M6G-020026--- The length is 75mm when ACGO is not configured. 53 630 PU tube 8*5.5 M6G-020045--- / 54 280 PU tube 8*5.5 M6G-020045--- / 55 460 PU tube 6*4 M6G-020026--- / 56 60 PU tube 6*4 M6G-020026--- Only available when auxiliary O2 supply is configured. 57 380 PU tube 6*4 M6G-020026--- Only available when auxiliary O2 supply is configured. 58 200 PU tube 8*5.5 M6G-020045--- / 60 150 PU tube 8*5.5 M6G-020045--- / 62 120 PU tube 8*5.5 M6G-020045--- / 63 70 PU tube 8*5.5 M6G-020045--- / 64 135 PU tube 8*5.5 M6G-020045--- / 6-68 68 280 PU tube 8*5.5 M6G-020045--- / 69 100 PU tube 8*5.5 M6G-020045--- / Select the following tubes when O2 and Air cylinders are configured 85 300/230 8*5.5 M6G-020045--- The length is 300mm for European standard and 230mm for American standard/American European standard. 88 120/290 8*5.5 M6G-020045--- The length is 120mm for European standard and 290mm for American standard/American European standard. 89 120 8*5.5 M6G-020045--- / Select the following tubes when O2 and N2O cylinders are configured 82 280 8*5.5 M6G-020045--- / 83 85 8*5.5 M6G-020045--- / M6G-020045--- The length is 270mm for European standard and 370mm for American standard/American European standard. 84 270/370 85 300/230 PU tube 8*5.5 8*5.5 The length is 300mm for European standard and 230mm for American standard/American European standard. M6G-020045--- elect the following tubes when only one O2 cylinder is configured 85 300/230 8*5.5 M6G-020045--- The length is 300mm for European standard and 230mm for American standard/American European standard. Select the following tubes when two O2 cylinders are configured 85 80 8*5.5 M6G-020045--- / 86 135 8*5.5 M6G-020045--- / 87 205 8*5.5 M6G-020045--- / 6-69 Notes: 1. When N2O cylinder is not configured, connect the N2O supply inlet assembly directly to the pressure regulator assembly. The tubes used and their Nos. are same to those in Appendix 2 (tube No.: 61#, tube length: 460±10mm, diameter: 8*5.5). 2. When Air cylinder is not configured, insert tube 54# into B4-3 directly. 3. When only one O2 cylinder is configured, insert tube 85# directly into the connector of O2 cylinder yoke 1. 4. A indicates connector: Tube to Tube Y piece 3140-06-00,P/N:M6Q-030024---, indicated by A1 and A2 in the diagram. 5. B indicates connector: Tube to Tube Y piece 3140-08-00,P/N:M6Q-030025--, indicated by B1 and B2 in the diagram (P/N of B3 is 082-000448-00). 6. C and C2 indicate connector: different diameter Tube to Tube, straight connector, 3106-06-08,P/N:M6Q-030051---. 6-70