Document Title:
I Effective from 02.06.2022
I RDSO/SPN/196/2020
I Version 4.0
d3
Specification of Kavach (The Indian Railway ATP)- KAVACH Station Master Operation and
Indication Panel (SM-OCIP) Requirements
Annexure-Q
Annexure -Q
Station Master
(SM-OCI
Printed:
Nagendra Singh
JE/S&T
R. N. Singh
ADE/Signal - V
M.M. Srivastava
DirectorrlSig-IV
Page 1 of 3
ISO 9001: 2015
I
Document Title:
Effective from 02.06.2022
RDSO/SPN/196/2020
Version 4.0 d3
Specification of Kavach (The Indian Railway ATP)- KAVACH Station Master Operation and
Indication Panel SM-OCIP) Re uirernents
Annexure-
Introduction
Q.l
This document describes the SM-OCIP requirements to be used for the purpose of
Stationary KA VACH System
Requirements
Q.2
Q.2.1
SM-OCIP shall provide the following
Q.2.2
L
LED Indications
H.
Switches
IlL
LCD Panel
IV.
Buzzer
v.
6 digits counter which are updated on SO
VI.
Station Master's key.
It shall provide the following LED Indicatlo~""". ..•.•..•
2
3
LED Name
HEALTH OK
HEALTH FAIL
SOS
1
RED
YELLOW
Common switch to press along with SOS
switch
To cancel the SOS from station
To enerate SOS from Station
To acknowledge TSR
-0 IP shall not allow switches functionality without SM-KEY insertion into
SM-OCIP.
A 4 Line X 20 Characters LCD panel shall be provided on the console for Stationary KAVACH for display purpose
Q.2.6
The SM-OCIP shall display the following information on LCD:
1.
Station ID KMS Key Index, TSR Count along with the Station KAVACH OK or FAIL. (Line-l shall display the "ID:00531 KI:XX
T;.KX" ,Line-4 shall display the "STN KAVACH OK/SYSTEM
LINK FAIL" ).
11.
Software checksums of all modules along with the Application data
Printed :
Nagendra Singh
JE/S&T
R. N. Singh
ADE/Signal-V
M.M. Srivastava
DirectorrlSig-IV
G.
van Kumar
ED/Tele-U
Page 2 of 3
ISO 9001: 2015
Document Title:
I Effective from 02.06.2022
I Version
IRDSO/SPN/196/2020
4.0 d3
Specification of Kavach (The Indian Railway ATP)- KAVACH Station Master Operation and
Indication Panel (SM-OCIP) Requirements
Annexure-Q
checksum shall be display On Pressing COMMON button, after 1 minute it shall clear the LCD display.
lll.
Sub - System faults information Station KAVACH Manual SOS generated information shall be displayed as follows (Line-2 shall display
"SOS PRESSED") and Cancelled (Line-3 shall display "CANCEL
PRESSED")
Q.2.7
Stationary KAVACH shall blink SOS LED in SM-OCIP console when manual
SOS is generated.
Q.2.8
Stationary KAVACH shall drive Buzzer in SM-OClP console wne
SOS is generated
Q.2.9
Stationary KAVACH shall increment
counter after pressing the manual SOS.
Q.3
Installation of SM-OCIP
tatio Relay Room of the station Master's table or a nearby
wall such that it is accessible and i~ib to the S ation Master. 12 Core signalling cable shall be used for button, counter !8vpower supply. 10 pair PUF cable
shall be used for communic a
ortion. The typical SM-OCIP looks like the
below diagram
ST. lION
('FERA'JION.CUII.I
GER"S
lION PAIEL
(SfM.OCIp)
1EM.1H0K
SIlKEY
LCD
$OS
199999
91
SOSCounter
0
~
0
CMICB..
HEAL,..
FAL
0
50S
TSR-ACK
~