Spectrophotocolorimeter Test Report 1 Of 6 Plant optics Test Report 9.3 SDCM 1.200 1.000 Spectrum 0.800 0.600 0.400 0.200 0.000 200 300 400 500 600 Wavelength(nm) 700 800 x=0.380 y=0.380 F4000 Plant Parameters: Flux(lm): 174502 Spectral radiance(W/nm): 622.4 Flux(W): 602 Efficiency: 0.6126 Kp(PPE)(umol/J): 2.902 Erb_Ratio: 1.648 Flux_UV(W): 0.02497 PPF.t(umol): 2851 Flux(400-700)(W): 602 Flux_ch-A(W): 111 Flux_ch-B(W): 124.6 Flux b(W): 137.8 Flux y(W): 236.9 Flux r(W) : 227.2 Qv(lm.s): 174502 Qe(J): 622.4 Far-red flux(W): 19.88 Effi-fr: 0.02023 Kfr: 0.1232 Flux_b(W): 621.9 Flux_fr(W): 19.88 Photon flux_fr(umol/s): 121.1 Flux(380-780)(W): 621.4 Flux_ch-A.t(J): 111 Flux_ch-B.t(J): 0.1246 Flux b.t(J): 137.8 Flux y.t(J): 236.9 Flux r.t(J): 227.2 PPF(400-700)(umol/s): 2851 PPF(500-600)(umol/s): 1097 PPF(200-800)(umol/s): 2973 PPF(400-500)(umol/s): 531.6 PPF(600-700)(umol/s): 1222 PPF(280-800)(umol/s): 2973 Electrical Parameters: Lamp : U=238.3V I=4.157A P=982.6W PF=0.9920 Product Type:LEDZW008 1000W8条 Number:001 Temperature:25.3 deg Test Operator:Lianjia Software:V3.00.124 Remarks: Freq=60.01Hz Manufacturer:EVERFINE Test Department: Humidity:65.0% Test Date:2022-07-21 09:47:41 Instrument:PMS-2000 (SN:M181843CS1401115) Spectrophotocolorimeter Test Report 2 Of 6 UV Radiation: Euva 24.409 mW UV-A irradiance Euvb 0.563 mW UV-B irradiance Euvc 8.4611 mW UV-C irradiance Kuva 0.13988 mW/klm Ratio of the UV-A radiometric quantity to the photometri Kuvb 0.0032263 mW/klm Ratio of the UV-B radiometric quantity to the photometri Kuvc 0.048487 mW/klm Ratio of the UV-C radiometric quantity to the photometri Euva_eff 0.0024433 mW UV-A effective ultraviolet irradiance Euvb_eff 0.19323 mW UV-B effective ultraviolet irradiance Euvc_eff 1.9936 mW UV-C effective ultraviolet irradiance Kuva_eff 1.4002e-005 mW/klm Ratio of UV-A effective radiometric quantity to the phot Kuvb_eff 0.0011073 mW/klm Ratio of UV-B effective radiometric quantity to the phot Kuvc_eff 0.011425 mW/klm Ratio of UV-C effective radiometric quantity to the phot UVA+UVB 0.0011214 mW/klm Sum of Euva_eff and Euvb_eff Euv_eff 1.2532e-005 mW Effective ultraviolet irradiance for wavelength from 250 Kuv(250-400) 3.3296e-008 mW/klm Ratio of effective ultraviolet radiometric quantity for Kuv(200-400) 7.1873e-008 mW/klm Ratio of effective ultraviolet radiometric quantity for Euv 33.433 mW Irradiance for wavelength from 250nm to 400nm Kred 13.997 % Ratio of the photometric quantity in 610nm-780nm to the E(s) 2.1886 mW Effective ultraviolet irradiance for wavelength from 200 E(b) 1.0427e+005 mW Blue light hazard weighted irradiance E(vis) 6.2149e+005 mW Irradiance for wavelength from 380nm to 780nm ECE37 k1 0.13988 mW/klm Ratio of the radiometric quantity for wavelength from 31 ECE37 k2 0.0085652 mW/klm Ratio of the radiometric quantity for wavelength from 25 Product Type:LEDZW008 1000W8条 Number:001 Temperature:25.3 deg Test Operator:Lianjia Software:V3.00.124 Remarks: Manufacturer:EVERFINE Test Department: Humidity:65.0% Test Date:2022-07-21 09:47:41 Instrument:PMS-2000 (SN:M181843CS1401115) Spectrophotocolorimeter Test Report 3 Of 6 Plant optics Test Report 9.4 SDCM 1.200 1.000 Spectrum 0.800 0.600 0.400 0.200 0.000 200 300 400 500 600 Wavelength(nm) 700 800 x=0.380 y=0.380 F4000 Plant Parameters: Flux(lm): 174075 Spectral radiance(W/nm): 621.1 Flux(W): 600.6 Efficiency: 0.6143 Kp(PPE)(umol/J): 2.909 Erb_Ratio: 1.643 Flux_UV(W): 0.02703 PPF.t(umol): 2845 Flux(400-700)(W): 600.6 Flux_ch-A(W): 110.6 Flux_ch-B(W): 124.3 Flux b(W): 137.8 Flux y(W): 236.4 Flux r(W) : 226.4 Qv(lm.s): 174075 Qe(J): 621.1 Far-red flux(W): 19.87 Effi-fr: 0.02032 Kfr: 0.1238 Flux_b(W): 620.5 Flux_fr(W): 19.87 Photon flux_fr(umol/s): 121.1 Flux(380-780)(W): 620.1 Flux_ch-A.t(J): 110.6 Flux_ch-B.t(J): 0.1243 Flux b.t(J): 137.8 Flux y.t(J): 236.4 Flux r.t(J): 226.4 PPF(400-700)(umol/s): 2845 PPF(500-600)(umol/s): 1095 PPF(200-800)(umol/s): 2966 PPF(400-500)(umol/s): 531.6 PPF(600-700)(umol/s): 1218 PPF(280-800)(umol/s): 2966 Electrical Parameters: Lamp : U=275.6V I=3.609A P=977.8W PF=0.9832 Product Type:LEDZW008 1000W8条 Number:002 Temperature:25.3 deg Test Operator:Lianjia Software:V3.00.124 Remarks: Freq=60.01Hz Manufacturer:EVERFINE Test Department: Humidity:65.0% Test Date:2022-07-21 09:51:40 Instrument:PMS-2000 (SN:M181843CS1401115) Spectrophotocolorimeter Test Report 4 Of 6 UV Radiation: Euva 25.692 mW UV-A irradiance Euvb 1.341 mW UV-B irradiance Euvc 6.5906 mW UV-C irradiance Kuva 0.14759 mW/klm Ratio of the UV-A radiometric quantity to the photometri Kuvb 0.0077036 mW/klm Ratio of the UV-B radiometric quantity to the photometri Kuvc 0.037861 mW/klm Ratio of the UV-C radiometric quantity to the photometri Euva_eff 0.0015478 mW UV-A effective ultraviolet irradiance Euvb_eff 0.7778 mW UV-B effective ultraviolet irradiance Euvc_eff 1.3721 mW UV-C effective ultraviolet irradiance Kuva_eff 8.8918e-006 mW/klm Ratio of UV-A effective radiometric quantity to the phot Kuvb_eff 0.0044682 mW/klm Ratio of UV-B effective radiometric quantity to the phot Kuvc_eff 0.0078823 mW/klm Ratio of UV-C effective radiometric quantity to the phot UVA+UVB 0.0044771 mW/klm Sum of Euva_eff and Euvb_eff Euv_eff 1.235e-005 mW Effective ultraviolet irradiance for wavelength from 250 Kuv(250-400) 3.4051e-008 mW/klm Ratio of effective ultraviolet radiometric quantity for Kuv(200-400) 7.1e-008 mW/klm Ratio of effective ultraviolet radiometric quantity for Euv 33.624 mW Irradiance for wavelength from 250nm to 400nm Kred 13.971 % Ratio of the photometric quantity in 610nm-780nm to the E(s) 2.1515 mW Effective ultraviolet irradiance for wavelength from 200 E(b) 1.042e+005 mW Blue light hazard weighted irradiance E(vis) 6.2013e+005 mW Irradiance for wavelength from 380nm to 780nm ECE37 k1 0.14759 mW/klm Ratio of the radiometric quantity for wavelength from 31 ECE37 k2 0.00939 mW/klm Ratio of the radiometric quantity for wavelength from 25 Product Type:LEDZW008 1000W8条 Number:002 Temperature:25.3 deg Test Operator:Lianjia Software:V3.00.124 Remarks: Manufacturer:EVERFINE Test Department: Humidity:65.0% Test Date:2022-07-21 09:51:40 Instrument:PMS-2000 (SN:M181843CS1401115) Spectrophotocolorimeter Test Report 5 Of 6 Plant optics Test Report 9.4 SDCM 1.200 1.000 Spectrum 0.800 0.600 0.400 0.200 0.000 200 300 400 500 600 Wavelength(nm) 700 800 x=0.380 y=0.380 F4000 Plant Parameters: Flux(lm): 173640 Spectral radiance(W/nm): 619.4 Flux(W): 599.1 Efficiency: 0.586 Kp(PPE)(umol/J): 2.775 Erb_Ratio: 1.637 Flux_UV(W): 0.02064 PPF.t(umol): 2837 Flux(400-700)(W): 599.1 Flux_ch-A(W): 110.2 Flux_ch-B(W): 124 Flux b(W): 137.7 Flux y(W): 235.8 Flux r(W) : 225.5 Qv(lm.s): 173640 Qe(J): 619.4 Far-red flux(W): 19.7 Effi-fr: 0.01927 Kfr: 0.1174 Flux_b(W): 618.9 Flux_fr(W): 19.7 Photon flux_fr(umol/s): 120 Flux(380-780)(W): 618.4 Flux_ch-A.t(J): 110.2 Flux_ch-B.t(J): 0.1240 Flux b.t(J): 137.7 Flux y.t(J): 235.8 Flux r.t(J): 225.5 PPF(400-700)(umol/s): 2837 PPF(500-600)(umol/s): 1092 PPF(200-800)(umol/s): 2957 PPF(400-500)(umol/s): 531.3 PPF(600-700)(umol/s): 1213 PPF(280-800)(umol/s): 2957 Electrical Parameters: Lamp : U=120.2V I=8.510A P=1022W PF=0.9993 Product Type:LEDZW008 1000W8条 Number:003 Temperature:25.3 deg Test Operator:Lianjia Software:V3.00.124 Remarks: Freq=60.01Hz Manufacturer:EVERFINE Test Department: Humidity:65.0% Test Date:2022-07-21 09:56:46 Instrument:PMS-2000 (SN:M181843CS1401115) Spectrophotocolorimeter Test Report 6 Of 6 UV Radiation: Euva 20.642 mW UV-A irradiance Euvb 0 mW UV-B irradiance Euvc 0 mW UV-C irradiance Kuva 0.11888 mW/klm Ratio of the UV-A radiometric quantity to the photometri Kuvb 0 mW/klm Ratio of the UV-B radiometric quantity to the photometri Kuvc 0 mW/klm Ratio of the UV-C radiometric quantity to the photometri Euva_eff 0.0010435 mW UV-A effective ultraviolet irradiance Euvb_eff 0 mW UV-B effective ultraviolet irradiance Euvc_eff 0 mW UV-C effective ultraviolet irradiance Kuva_eff 6.0096e-006 mW/klm Ratio of UV-A effective radiometric quantity to the phot Kuvb_eff 0 mW/klm Ratio of UV-B effective radiometric quantity to the phot Kuvc_eff 0 mW/klm Ratio of UV-C effective radiometric quantity to the phot UVA+UVB 6.0096e-006 mW/klm Sum of Euva_eff and Euvb_eff Euv_eff 0 mW Effective ultraviolet irradiance for wavelength from 250 Kuv(250-400) 3.461e-011 mW/klm Ratio of effective ultraviolet radiometric quantity for Kuv(200-400) 3.461e-011 mW/klm Ratio of effective ultraviolet radiometric quantity for Euv 20.642 mW Irradiance for wavelength from 250nm to 400nm Kred 13.948 % Ratio of the photometric quantity in 610nm-780nm to the E(s) 0.0010435 mW Effective ultraviolet irradiance for wavelength from 200 E(b) 1.041e+005 mW Blue light hazard weighted irradiance E(vis) 6.1848e+005 mW Irradiance for wavelength from 380nm to 780nm ECE37 k1 0.11888 mW/klm Ratio of the radiometric quantity for wavelength from 31 ECE37 k2 0 mW/klm Ratio of the radiometric quantity for wavelength from 25 Product Type:LEDZW008 1000W8条 Number:003 Temperature:25.3 deg Test Operator:Lianjia Software:V3.00.124 Remarks: Manufacturer:EVERFINE Test Department: Humidity:65.0% Test Date:2022-07-21 09:56:46 Instrument:PMS-2000 (SN:M181843CS1401115)