Uploaded by Volodymyr Krytskyi

Test Report 2 902umol LED1000W PRO+

advertisement
Spectrophotocolorimeter Test Report
1 Of 6
Plant optics Test Report
9.3 SDCM
1.200
1.000
Spectrum
0.800
0.600
0.400
0.200
0.000
200
300
400
500
600
Wavelength(nm)
700
800
x=0.380 y=0.380 F4000
Plant Parameters:
Flux(lm): 174502
Spectral radiance(W/nm): 622.4
Flux(W): 602
Efficiency: 0.6126
Kp(PPE)(umol/J): 2.902
Erb_Ratio: 1.648
Flux_UV(W): 0.02497
PPF.t(umol): 2851
Flux(400-700)(W): 602
Flux_ch-A(W): 111
Flux_ch-B(W): 124.6
Flux b(W): 137.8
Flux y(W): 236.9
Flux r(W) : 227.2
Qv(lm.s): 174502
Qe(J): 622.4
Far-red flux(W): 19.88
Effi-fr: 0.02023
Kfr: 0.1232
Flux_b(W): 621.9
Flux_fr(W): 19.88
Photon flux_fr(umol/s): 121.1
Flux(380-780)(W): 621.4
Flux_ch-A.t(J): 111
Flux_ch-B.t(J): 0.1246
Flux b.t(J): 137.8
Flux y.t(J): 236.9
Flux r.t(J): 227.2
PPF(400-700)(umol/s): 2851
PPF(500-600)(umol/s): 1097
PPF(200-800)(umol/s): 2973
PPF(400-500)(umol/s): 531.6
PPF(600-700)(umol/s): 1222
PPF(280-800)(umol/s): 2973
Electrical Parameters:
Lamp
: U=238.3V
I=4.157A
P=982.6W PF=0.9920
Product Type:LEDZW008 1000W8条
Number:001
Temperature:25.3 deg
Test Operator:Lianjia
Software:V3.00.124
Remarks:
Freq=60.01Hz
Manufacturer:EVERFINE
Test Department:
Humidity:65.0%
Test Date:2022-07-21 09:47:41
Instrument:PMS-2000 (SN:M181843CS1401115)
Spectrophotocolorimeter Test Report
2 Of 6
UV Radiation:
Euva
24.409 mW
UV-A irradiance
Euvb
0.563 mW
UV-B irradiance
Euvc
8.4611 mW
UV-C irradiance
Kuva
0.13988 mW/klm
Ratio of the UV-A radiometric quantity to the photometri
Kuvb
0.0032263 mW/klm
Ratio of the UV-B radiometric quantity to the photometri
Kuvc
0.048487 mW/klm
Ratio of the UV-C radiometric quantity to the photometri
Euva_eff
0.0024433 mW
UV-A effective ultraviolet irradiance
Euvb_eff
0.19323 mW
UV-B effective ultraviolet irradiance
Euvc_eff
1.9936 mW
UV-C effective ultraviolet irradiance
Kuva_eff
1.4002e-005 mW/klm
Ratio of UV-A effective radiometric quantity to the phot
Kuvb_eff
0.0011073 mW/klm
Ratio of UV-B effective radiometric quantity to the phot
Kuvc_eff
0.011425 mW/klm
Ratio of UV-C effective radiometric quantity to the phot
UVA+UVB
0.0011214 mW/klm
Sum of Euva_eff and Euvb_eff
Euv_eff
1.2532e-005 mW
Effective ultraviolet irradiance for wavelength from 250
Kuv(250-400)
3.3296e-008 mW/klm
Ratio of effective ultraviolet radiometric quantity for
Kuv(200-400)
7.1873e-008 mW/klm
Ratio of effective ultraviolet radiometric quantity for
Euv
33.433 mW
Irradiance for wavelength from 250nm to 400nm
Kred
13.997 %
Ratio of the photometric quantity in 610nm-780nm to the
E(s)
2.1886 mW
Effective ultraviolet irradiance for wavelength from 200
E(b)
1.0427e+005 mW
Blue light hazard weighted irradiance
E(vis)
6.2149e+005 mW
Irradiance for wavelength from 380nm to 780nm
ECE37 k1
0.13988 mW/klm
Ratio of the radiometric quantity for wavelength from 31
ECE37 k2
0.0085652 mW/klm
Ratio of the radiometric quantity for wavelength from 25
Product Type:LEDZW008 1000W8条
Number:001
Temperature:25.3 deg
Test Operator:Lianjia
Software:V3.00.124
Remarks:
Manufacturer:EVERFINE
Test Department:
Humidity:65.0%
Test Date:2022-07-21 09:47:41
Instrument:PMS-2000 (SN:M181843CS1401115)
Spectrophotocolorimeter Test Report
3 Of 6
Plant optics Test Report
9.4 SDCM
1.200
1.000
Spectrum
0.800
0.600
0.400
0.200
0.000
200
300
400
500
600
Wavelength(nm)
700
800
x=0.380 y=0.380 F4000
Plant Parameters:
Flux(lm): 174075
Spectral radiance(W/nm): 621.1
Flux(W): 600.6
Efficiency: 0.6143
Kp(PPE)(umol/J): 2.909
Erb_Ratio: 1.643
Flux_UV(W): 0.02703
PPF.t(umol): 2845
Flux(400-700)(W): 600.6
Flux_ch-A(W): 110.6
Flux_ch-B(W): 124.3
Flux b(W): 137.8
Flux y(W): 236.4
Flux r(W) : 226.4
Qv(lm.s): 174075
Qe(J): 621.1
Far-red flux(W): 19.87
Effi-fr: 0.02032
Kfr: 0.1238
Flux_b(W): 620.5
Flux_fr(W): 19.87
Photon flux_fr(umol/s): 121.1
Flux(380-780)(W): 620.1
Flux_ch-A.t(J): 110.6
Flux_ch-B.t(J): 0.1243
Flux b.t(J): 137.8
Flux y.t(J): 236.4
Flux r.t(J): 226.4
PPF(400-700)(umol/s): 2845
PPF(500-600)(umol/s): 1095
PPF(200-800)(umol/s): 2966
PPF(400-500)(umol/s): 531.6
PPF(600-700)(umol/s): 1218
PPF(280-800)(umol/s): 2966
Electrical Parameters:
Lamp
: U=275.6V
I=3.609A
P=977.8W PF=0.9832
Product Type:LEDZW008 1000W8条
Number:002
Temperature:25.3 deg
Test Operator:Lianjia
Software:V3.00.124
Remarks:
Freq=60.01Hz
Manufacturer:EVERFINE
Test Department:
Humidity:65.0%
Test Date:2022-07-21 09:51:40
Instrument:PMS-2000 (SN:M181843CS1401115)
Spectrophotocolorimeter Test Report
4 Of 6
UV Radiation:
Euva
25.692 mW
UV-A irradiance
Euvb
1.341 mW
UV-B irradiance
Euvc
6.5906 mW
UV-C irradiance
Kuva
0.14759 mW/klm
Ratio of the UV-A radiometric quantity to the photometri
Kuvb
0.0077036 mW/klm
Ratio of the UV-B radiometric quantity to the photometri
Kuvc
0.037861 mW/klm
Ratio of the UV-C radiometric quantity to the photometri
Euva_eff
0.0015478 mW
UV-A effective ultraviolet irradiance
Euvb_eff
0.7778 mW
UV-B effective ultraviolet irradiance
Euvc_eff
1.3721 mW
UV-C effective ultraviolet irradiance
Kuva_eff
8.8918e-006 mW/klm
Ratio of UV-A effective radiometric quantity to the phot
Kuvb_eff
0.0044682 mW/klm
Ratio of UV-B effective radiometric quantity to the phot
Kuvc_eff
0.0078823 mW/klm
Ratio of UV-C effective radiometric quantity to the phot
UVA+UVB
0.0044771 mW/klm
Sum of Euva_eff and Euvb_eff
Euv_eff
1.235e-005 mW
Effective ultraviolet irradiance for wavelength from 250
Kuv(250-400)
3.4051e-008 mW/klm
Ratio of effective ultraviolet radiometric quantity for
Kuv(200-400)
7.1e-008 mW/klm
Ratio of effective ultraviolet radiometric quantity for
Euv
33.624 mW
Irradiance for wavelength from 250nm to 400nm
Kred
13.971 %
Ratio of the photometric quantity in 610nm-780nm to the
E(s)
2.1515 mW
Effective ultraviolet irradiance for wavelength from 200
E(b)
1.042e+005 mW
Blue light hazard weighted irradiance
E(vis)
6.2013e+005 mW
Irradiance for wavelength from 380nm to 780nm
ECE37 k1
0.14759 mW/klm
Ratio of the radiometric quantity for wavelength from 31
ECE37 k2
0.00939 mW/klm
Ratio of the radiometric quantity for wavelength from 25
Product Type:LEDZW008 1000W8条
Number:002
Temperature:25.3 deg
Test Operator:Lianjia
Software:V3.00.124
Remarks:
Manufacturer:EVERFINE
Test Department:
Humidity:65.0%
Test Date:2022-07-21 09:51:40
Instrument:PMS-2000 (SN:M181843CS1401115)
Spectrophotocolorimeter Test Report
5 Of 6
Plant optics Test Report
9.4 SDCM
1.200
1.000
Spectrum
0.800
0.600
0.400
0.200
0.000
200
300
400
500
600
Wavelength(nm)
700
800
x=0.380 y=0.380 F4000
Plant Parameters:
Flux(lm): 173640
Spectral radiance(W/nm): 619.4
Flux(W): 599.1
Efficiency: 0.586
Kp(PPE)(umol/J): 2.775
Erb_Ratio: 1.637
Flux_UV(W): 0.02064
PPF.t(umol): 2837
Flux(400-700)(W): 599.1
Flux_ch-A(W): 110.2
Flux_ch-B(W): 124
Flux b(W): 137.7
Flux y(W): 235.8
Flux r(W) : 225.5
Qv(lm.s): 173640
Qe(J): 619.4
Far-red flux(W): 19.7
Effi-fr: 0.01927
Kfr: 0.1174
Flux_b(W): 618.9
Flux_fr(W): 19.7
Photon flux_fr(umol/s): 120
Flux(380-780)(W): 618.4
Flux_ch-A.t(J): 110.2
Flux_ch-B.t(J): 0.1240
Flux b.t(J): 137.7
Flux y.t(J): 235.8
Flux r.t(J): 225.5
PPF(400-700)(umol/s): 2837
PPF(500-600)(umol/s): 1092
PPF(200-800)(umol/s): 2957
PPF(400-500)(umol/s): 531.3
PPF(600-700)(umol/s): 1213
PPF(280-800)(umol/s): 2957
Electrical Parameters:
Lamp
: U=120.2V
I=8.510A
P=1022W PF=0.9993
Product Type:LEDZW008 1000W8条
Number:003
Temperature:25.3 deg
Test Operator:Lianjia
Software:V3.00.124
Remarks:
Freq=60.01Hz
Manufacturer:EVERFINE
Test Department:
Humidity:65.0%
Test Date:2022-07-21 09:56:46
Instrument:PMS-2000 (SN:M181843CS1401115)
Spectrophotocolorimeter Test Report
6 Of 6
UV Radiation:
Euva
20.642 mW
UV-A irradiance
Euvb
0 mW
UV-B irradiance
Euvc
0 mW
UV-C irradiance
Kuva
0.11888 mW/klm
Ratio of the UV-A radiometric quantity to the photometri
Kuvb
0 mW/klm
Ratio of the UV-B radiometric quantity to the photometri
Kuvc
0 mW/klm
Ratio of the UV-C radiometric quantity to the photometri
Euva_eff
0.0010435 mW
UV-A effective ultraviolet irradiance
Euvb_eff
0 mW
UV-B effective ultraviolet irradiance
Euvc_eff
0 mW
UV-C effective ultraviolet irradiance
Kuva_eff
6.0096e-006 mW/klm
Ratio of UV-A effective radiometric quantity to the phot
Kuvb_eff
0 mW/klm
Ratio of UV-B effective radiometric quantity to the phot
Kuvc_eff
0 mW/klm
Ratio of UV-C effective radiometric quantity to the phot
UVA+UVB
6.0096e-006 mW/klm
Sum of Euva_eff and Euvb_eff
Euv_eff
0 mW
Effective ultraviolet irradiance for wavelength from 250
Kuv(250-400)
3.461e-011 mW/klm
Ratio of effective ultraviolet radiometric quantity for
Kuv(200-400)
3.461e-011 mW/klm
Ratio of effective ultraviolet radiometric quantity for
Euv
20.642 mW
Irradiance for wavelength from 250nm to 400nm
Kred
13.948 %
Ratio of the photometric quantity in 610nm-780nm to the
E(s)
0.0010435 mW
Effective ultraviolet irradiance for wavelength from 200
E(b)
1.041e+005 mW
Blue light hazard weighted irradiance
E(vis)
6.1848e+005 mW
Irradiance for wavelength from 380nm to 780nm
ECE37 k1
0.11888 mW/klm
Ratio of the radiometric quantity for wavelength from 31
ECE37 k2
0 mW/klm
Ratio of the radiometric quantity for wavelength from 25
Product Type:LEDZW008 1000W8条
Number:003
Temperature:25.3 deg
Test Operator:Lianjia
Software:V3.00.124
Remarks:
Manufacturer:EVERFINE
Test Department:
Humidity:65.0%
Test Date:2022-07-21 09:56:46
Instrument:PMS-2000 (SN:M181843CS1401115)
Download