FLAT COVERS Special Product: FLAT COVERS GLUED AND Type CL-SIM SEWN Glued style “A” AP AP a x Formula for calculating the CLOSED LENGTH P. C.= NP . 4 + lange thickness x d P.A. NP= Number of folds = B AP= Opening of 1 fold = x . 1,41 AP Sewn style “C” Type TL-SIM AP 4 AP 4 x a Reproduction of this page is strictly prohibited. +2 AP Formula for calculating the CLOSED LENGTH P. C.= NP . 2,5 + flange thickness x NP= Number of folds = P.A. +2 AP AP= Opening of 1 fold = (x-8) . 1,41 B AP P.A. P.C. Mobile carriage Contact our engineering department for this type of cover. NOTE: The data fields and/or tables marked by Ref. P.A. Open length Description P.C. Closed length Dim. Type Style Stroke (P.A. - P.C.) a Outside height B Outside width x Fold height d Return dimension AP Fold opening NP Number of folds are the least ones to be filled in order to give you a quotation. www.pei.it 39