327 FIRE FIRE DIVISION CONTACT LIST Ceri Chadwick-Dunbar UK Fire Sales Manager Peter Holmes Mob 07730 804 537 ceri.chadwick-dunbar@adi-gardiner.com Mark Wild Technical Support Tel: 01706 510 515 Fax: 01706 861 125 Business Product Manager Fire Tel: 0161 767 2933 (Direct) Mob 07836 276 771 peter.holmes@adi-gardiner.com Duncan Mudie mark.wild@adi-gardiner.com Technical Support Tel: 01706 510 516 Fax: 01706 861 125 duncan.mudie@adi-gardiner.com Campbell Bailey Aberdeen Edinburgh Scotland Carlisle Glasgow Mob 07768 947 093 campbell.bailey@adi-gardiner.com Mike Slater Bolton Preston Salford North West Belfast Liverpool Rochdale Mob 07766 315 882 Eric Bowman Hull Newcastle Teeside North East Leeds Sheffield Mob 07770 632 590 eric.bowman@adi-gardiner.com mike.slater@adi-gardiner.com Mike Parlett Stoke Leicester Nottingham Midlands Birmingham Northampton Mob 07767 327 762 Robin Smith Bristol Exeter South West & Wales Cardiff mike.parlett@adi-gardiner.com Mob 07891 254 847 robin.smith@adi-gardiner.com Ian Cowham Enfield Luton North London Kingsbury John Palmer Beckton Norwich East Anglia & NE London Chelmsford Mob 07891 254 865 Mob 07854 255 789 ian.cowham@adi-gardiner.com Karl Tart Catford Crawley Croydon London & South East Merton Strood Crayford john.palmer@adi-gardiner.com John Lock Reading Poole Aldershot Mob 07778 558 129 Mob 07768 303 715 karl.tart@adi-gardiner.com South Central Eastleigh Oxford john.lock@adi-gardiner.com 328 FIRE INDEX Non-Addressable Fire Alarm Systems C-Tec Non-Addressable Fire Alarm Control Panels Kentec Non-Addressable Fire Alarm Control Panels 330-331 332 Ventcroft Non-Addressable Fire Alarm Control Panels 333 2 Wire Addressable & Non-Addressable Fire Alarm Systems Alarmsense 2 Wire Non-Addressable Fire Alarm Systems 334 Firesense 2 Wire Non-Addressable Fire Alarm Systems 335 332 C-Tec Extinguishant System 338 Rafiki 2 Wire Non-Addressable Fire Alarm System 336-337 Rafiki 2-Wire Addressable Fire Alarm Systems 337 Extinguishant Systems Kentec Extinguishant Control Panel Non-Addressable Detectors & Manual Callpoints Hochiki Non-Addressable Detectors Apollo Non-Addressable Detectors The Fire Beam Company Linear Beam Smoke Detectors Hochiki Linear Beam Smoke Detectors 339 340 Fire Fighting Enterprises (FFE) Linear Beam Smoke Detectors 342-343 KAC Non-Addressable Manual Callpoints 344-345 Fulleon Non-Addressable Manual Callpoints 346 341 341 Analogue Addressable Equipment C-Tec Analogue Addressable Fire Alarm Control Panels Advanced Analogue Addressable Fire Alarm Control Panels Morley IAS Analogue Addressable Fire Alarm Control Panels 356-357 Kentec Analogue Addressable Fire Alarm Control Panels 358 354 355 STI Non-Addressable Manual Callpoints CQR/STI/Vimpex Non-Addressable Manual Callpoints Intruder Panel Detectors Domestic Detectors C/O Detectors 347 348 349 349 349 Hochiki Analogue Addressable Detectors, Sounders & Interfaces 359 Apollo Analogue Addressable Detectors, Sounders & Interfaces 360-362 Integrated Building Protection 363 Audio & Visual Alarms (Sounders, Strobes & Bells) Fulleon Cranford Controls 364-365 366-367 Klaxon 368-369 Vimpex 370-371 24V Power Supply Units STI – Cages, Stoppers etc Fire Resistant Cable & Ancillaries 373-374 375 376-378 C-Tec Quantec Addressable Call Systems 390-391 Ancillary Fire Products No Climb Detector Test Equipment RedCare Fire Stu’s Ancillaries – Relays, Remote LED’s, Door Retainers etc Water Leakage Detection System Custom Electronics Automatic Opening Vent Controls (AOV’s) 350 351 353 372 352 Emergency Lighting Spel 379-381 Emergi-Lite 382-383 Voice Alarm Systems Signet System 384 Signet AVAC 385 C-Tec Waiting Room Call System Ventcroft Disabled Toilet Alarm 388 389 Call Systems & Disabled Toilet Alarms C-Tec Nursecall Systems/Disabled Toilet Alarms 386-387 Induction Loop Systems Induction Loop Systems 392-393 Disabled Refuge Systems Disabled Refuge Systems 394 Vertical Markets 2-3 Online Ordering 4 Fire Division Contact Information 328 ADI-GARDINER – ICEL Emergency Lighting Training Schedule 2008 395 329 ADI-GARDINER – Supplier Product Training Schedule 2008 395 ADI-GARDINER – FIA Training Schedule 2008 396-397 BSI Service 398 The Roadmap – Proof of Competence 399 Delivery and Information & Special Orders 610 Returns & Repair Policy 611 Terms and Conditions 612 Account Application Form 613-615 Branch Information 617 C-TEC CFP NON-ADDRESSABLE FIRE PANELS Code C-TEC CFP RANGE (to EN54 parts 2/4) • • • • • • • • • Available with 2, 4 or 8 detector zone circuits Four sounder circuits End of line units included (one per zone) Standard, economy and LPCB approved versions available Attractive flush or surface mountable plastic lid and enclosure Class change and alert inputs Auxiliary remote, aux. fire, fault and reset outputs Ancillary connections provided for up to eight two wire repeaters and optional Wide range of engineering functions including (dependent on model purchased) coincidence, zone test, zone delay and non-latching zones – see chart for details CFP STANDARD PANELS (to EN54 parts 2/4) 601-0383 CFP702-4 CFP standard two zone panel (does not extend) 601-0381 CFP704-4 CFP standard four zone panel (does not extend) 601-0379 CFP708-4 CFP standard eight zone panel (does not extend) CFP ECONOMY PANELS (to EN54 parts 2/4) ◆ ◆ ◆ 621-0070 CFP702E-4 CFP economy two zone panel (does not extend) 621-0073 CFP704E-4 CFP economy four zone panel (does not extend) 621-0075 CFP708E-4 CFP economy eight zone panel (does not extend) CFP LPCB APPROVED PANELS (to EN54 parts 2/4) C 601-0513 CFP702-4/LPC CFP LPCB approved two zone panel (does not extend) C 601-0514 CFP704-4/LPC CFP LPCB approved four zone panel (does not extend) C 601-0515 CFP708-4/LPC CFP LPCB approved eight zone panel (does not extend) CFP ANCILLARIES (for use with standard and LPCB approved CFPs only) 601-0395 CFP761 Network driver card (one required per repeater system) 601-0396 CFP760 8 zone repeater panel (max. eight per main) 601-0394 CFP762 4 relay output card (relays follow panel’s aux. outputs) 601-0393 CFP763 12 relay output card (as above plus 8 zonal relays) 601-0720 BF362 Barrier interface unit (allows a CFP zone circuit to be connected to up to 10 intrinsically safe detectors and call points via a Zenner barrier, not supplied) ◆ NEW GENERAL FIRE ANCILLARIES (for use with CFP, FP, MFP and other fire panels) 330 601-0181 FF502P Universal four zone sounder circuit extender kit 623-0257 BF376 24V 5A polarised relay on a single gang plate 620-0400 BF318 Remote LED indicator on a single gang plate 620-0399 BF367 Keyswitch operated device isolator on a single gang plate 620-0398 BF366 Keyswitch isolatable 24V 5A relay on a single gang plate 601-0648 BF365SC Sounder isolator controller, supplied on a double gang plate 601-0649 BF365IM Sounder isolator module (Max. 35 per BF365SC) ◆ C = Third Party Certified product FP RANGE MFP RANGE NON-ADDRESSABLE FIRE PANELS (continued) Code C-TEC FP RANGE (to BS5839 part 4) • • • • • • • • • • Available with 2 to 14 detector zone circuits (in 2 zone steps) Two sounder circuits Lift-off lid for easy first fix and straightforward maintenance Robust metal lid, metal back box and heavy duty base connections One end of line monitor unit required per zone for head removal indication Separate indicators for open and short circuit faults, sounder fault and battery/PSU fault One man test and zone disable facility (not available on single zone version) Ancillary connections for repeater panels and optional expansion looms Optional short circuit = fire facility and true three wire operation of detector and sounder (0V is common) Ideal for retro BS installations 601-0006 FF380-2 FP 1 zone panel (EFP-1) 601-0187 FF380X EFP-X Expansion loom for EFP-1 601-0007 FF382-2 FP 2 zone panel (does not extend) 601-0008 FF384-2 FP 4 zone panel (expandable to 6 zones) 601-0009 FF386-2 FP 6 zone panel (does not expand) 601-0319 FF388-2 FP 8 zone panel (expandable to 14 zones) 601-0177 FF374X FP-X Expansion loom for FP 2-14 zone panels 601-0320 FF387Z-2 FP 2 zone extender board 601-0011 BF378 End of line monitor unit (1 required per zone for head out monitoring) 601-0114 FF396-2 FP 10 zone repeater panel (max. 3 per main panel) 601-0342 FF398-2 FP 20 zone repeater panel (max. 3 per main panel) C-TEC MFP RANGE (to BS5839 part 4) Features as per FP RANGE plus:Two extra sounder circuits (i.e. four sounder circuits per panel) End of line monitor units provided as standard (one per zone) Sounder disable and aux. disable facilities Non-latching zones and sounder delay (30 secs) facilities 601-0012 FF504 MFP 4 zone panel (expandable to 12 zones) 601-0013 FF516 MFP 16 zone panel (expandable to 28 zones) 601-0014 FF501Z MFP 4 zone extender PCB 604-0027 FF574X MFP-X expansion loom 601-0322 FF596T MFP repeater transmitter PCB (one required per repeater system) 601-0323 FF596 MFP 8 zone repeater panel (expands to 32 zones) 601-0324 FF596R MFP 8 zone extender PCB kit 331 Non-Addressable Fire Panels • • • • • NON-ADDRESSABLE FIRE PANELS (continued) Code N N N N N N KENTEC SIGMA CP EN-54 APPROVED FIRE CONTROL PANELS C 601-0640 2 Zone Conventional C 601-0641 4 Zone Conventional C 601-0642 8 Zone Conventional C 602-0056 2 Zone Two Wire C 602-0057 4 Zone Two Wire C 602-0058 8 Zone Two Wire 601-0643 LCMU Line Continuity Monitoring Unit 601-0686 Sigma CP Sounder PCB 601-0687 Sigma CP Ancillary PCB N C KENTEC EXTINGUISHANT CONTROL PANELS 620-0666 Sigma XT 620-0667 Sigma SI 6 lamp status unit 620-0668 Sigma Si 6 lamp status unit with mode select keyswitch 620-0669 Sigma SI 6 lamp status unit with mode select keyswitch and manual release 620-0670 Sigma SI 10 lamp status unit with mode select keyswitch and manual release 620-0931 Sigma Si Weatherproof (IP65) 6 lamp status unit 620-0879 Sigma Si Weatherproof (IP65) 6 lamp status unit with mode select keyswitch 620-0932 Sigma Si Weatherproof (IP65) 6 lamp status unit with mode select keyswitch and manual release 620-0933 Sigma Si Weatherproof (IP65) 10 lamp status unit with mode select keyswitch and manual release 620-0671 Sigma XT hold off switch unit 601-0688 Sigma XT Ancillary PCB KENTEC DOCUMENT ENCLOSURES 620-0672 Document Box Slim 620-0673 Document Box Deep KENTEC BATTERY CHARGERS & POWER SUPPLIES 621-0164 PSU 12V & 24V 750mA DC c/w Cabinet (max 7Ah Battery Capacity) 621-0179 PSU 24V 1.25A c/w Cabinet (max 7Ah Battery Capacity) 621-0165 PSU 24V 2.5A c/w Cabinet (max 7Ah Battery Capacity) 621-0180 PSU 24V 2.5A c/w Cabinet (max 17Ah Battery Capacity) C 621-0166 PSU 24V 4A EN54-4 c/w Cabinet (max 7Ah Battery Capacity) C 621-0181 PSU 24V 4A EN54-4 c/w Cabinet (max 17Ah Battery Capacity) C 621-0182 PSU 24V 4A EN54-4 c/w Cabinet (max 38Ah Battery Capacity) 621-0183 PSU 24V 10A c/w Cabinet (max 38Ah Battery Capacity) N N N KENTEC BATTERY BOXES 332 620-0674 Battery Box max 7Ah Battery Capacity 620-0675 Battery Box max 17Ah Battery Capacity 620-0677 Battery Box max 38Ah Battery Capacity 620-0678 Battery Box max 65Ah Battery Capacity (Grey Industrial Enclosure Only) N C = Third Party Certified product VENTCROFT COMPACT & PROFESSIONAL RANGES NON-ADDRESSABLE FIRE PANELS (continued) Code VENTCROFT FIRETRAX ‘’COMPACT’’ FIRE ALARM CONTROL PANELS - PC HOUSING 601-0610 1 Zone Fire Alarm Panel - 2 sounder circuits AEOL all zones - Key Switch & Keypad control EN54 Pt 2 & 4 601-0605 2 Zone Fire Alarm Panel - 2 sounder circuits AEOL all zones - Key Switch & Keypad control EN54 Pt 2 & 4 601-0607 4 Zone Fire Alarm Panel - 2 sounder circuits AEOL all zones - Key Switch & Keypad control EN54 Pt 2 & 4 VENTCROFT FIRETRAX ‘’PROFESSIONAL’’ FIRE ALARM CONTROL PANELS - METAL HOUSING/PC FRONT 601-0604 2 Zone Fire Alarm Panel - 2 sounder circuits AEOL all zones - Key Switch & Keypad control EN54 Pt 2 & 4 601-0606 4 Zone Fire Alarm Panel - 2 sounder circuits AEOL all zones - Key Switch & Keypad control EN54 Pt 2 & 4 601-0608 6 Zone Fire Alarm Panel - 2 sounder circuits AEOL all zones - Key Switch & Keypad control EN54 Pt 2 & 4 601-0609 8 Zone Fire Alarm Panel - 2 sounder circuits AEOL all zones - Key Switch & Keypad control EN54 Pt 2 & 4 333 334 C-TEC ALARMSENSE 2 WIRE NON-ADDRESSABLE FIRE ALARM SYSTEMS Code Intruder Fire Panel & Carbon Monoxide Detectors, Fire Extinguishers & Blankets FIRESENSE ALARMSENSE 602-0071 Alarmsense 2 zone fire panel 602-0072 Alarmsense 4 zone fire panel 602-0073 Alarmsense 4 zone fire panel (Large Case) 602-0074 Alarmsense 6 zone fire panel 602-0075 Alarmsense 8 zone fire panel 602-0076 Alarmsense 12 zone fire panel 602-0077 Bezel & Glass Door Kit for 8104 L, 8106, 8108 & 8112 602-0078 Bezel & Flush Kit for 8102 & 8104 601-0540 Bezel & Flush Kit for 8104L, 8106, 8108 & 8112 C-TEC ALARMSENSE N N N N N N N N N N N N N N N N N 601-0384 CFP Alarmsense 2 wire 2 zone fire panel 601-0382 CFP Alarmsense 2 wire 4 zone fire panel 601-0380 CFP Alarmsense 2 wire 8 zone fire panel 601-0395 CFP761 Network driver card (one required per repeater system) 601-0396 CFP760 8 zone repeater panel (max. eight per main) 601-0394 CFP762 4 relay output card (relays follow panel’s aux. outputs) 601-0393 CFP763 12 relay output card (as above plus 8 zonal relays) APOLLO FIRESENSE FIRE DETECTORS C 602-0064 Alarmsense Series Sounder Beacon Base and Detector Combination Optical Smoke Combination C 602-0065 Alarmsense Series Sounder Beacon Base and Detector Combination Integrating Optical Smoke Combination C 602-0066 Alarmsense Series Sounder Beacon Base and Detector Combination Standard Heat (A1R) Heat Combination C 602-0067 Alarmsense Series Sounder Beacon Base and Detector Combination High Temperature (CS) Heat Combination C 602-0063 Alarmsense Series Sounder Base and Detector Combinations Optical Smoke Combination C 602-0068 Alarmsense Series Sounder Base and Detector Combinations Integrating Optical Smoke Combination C 602-0069 Alarmsense Series Sounder Base and Detector Combinations Standard (A1R) Heat Combination C 602-0070 Alarmsense Series Sounder Base and Detector Combinations High Temperature (CS) Heat Combination C 601-0392 Alarmsense Series AlarmSense Optical Smoke Detector C 601-0650 Alarmsense Series AlarmSense Integrating Optical Smoke Detector C 601-0391 Alarmsense Series AlarmSense Standard (A1R) Heat Detector C 602-0033 Alarmsense Series AlarmSense High Temperature (CS) Heat Detector C 601-0390 Alarmsense Series AlarmSense Base with RemovAlert C 615-0120 Alarmsense Series AlarmSense Manual Call Point C 620-0717 Alarmsense Series AlarmSense Relay Module C 620-0718 Alarmsense Series AlarmSense Sounders with Integrated Base Sounder Base for Detector Mounting C 620-0719 Alarmsense Series AlarmSense Sounders with Integrated Base Sounder Beacon Base for Detector Mounting 620-0720 Alarmsense Series AlarmSense Sounders with Integrated Base Locking White Cap 620-0721 Alarmsense Series AlarmSense Sounders with Integrated Base Locking Red Cap 334 N C = Third Party Certified product FIRESENSE CONCEPT 2 WIRE NON-ADDRESSABLE FIRE ALARM SYSTEMS (continued) Code FIRESENSE 601-0370 Concept 2 zone fire panel 601-0371 Concept 4 zone fire panel 601-0372 Concept 6 zone fire panel 601-0373 Concept 8 zone fire panel 601-0374 Concept 12 zone fire panel 601-0453 Serial 16z Repeater (Must be ordered together with panel) 601-0540 Flush Bezel for 4/6/8 and 12 zone panels FULLEON SOUNDERS (for use on the above system) 618-0115 Symphoni 2 Wire Sounder Red- 100dB(A), 5mA 618-0113 Squashni Micro 2 Wire Red - 86dB(A) 3mA (low output), 95dB(A) 10mA (high output) 618-0112 Squashni Micro 2 Wire White - 86dB(A) 3mA (low output), 95dB(A) 10mA (high output) N NEW 618-0619 2 Wire Squashni Sounder Beacon CONVENTIONAL DETECTORS APOLLO CONVENTIONAL DETECTORS - SERIES 65 N N N N N N N N C 607-0192 Optical smoke detector C 607-0193 Ionisation smoke detector C 607-0351 Integrating ionisation smoke detector C 607-0194 A1R (57°C) Rate of Rise Heat C 607-0195 BR (75°C) Rate of Rise Heat C 607-0196 CR (90°C) Rate of Rise Heat C 607-0197 CS (90°C) Static Heat 607-0011 Standard base 607-0012 Diode base 607-0216 Conduit Box 607-0182 E-Z fit 6" base 607-0205 Standard relay base 608-0185 MiniDisc remote indicator C APOLLO CONVENTIONAL DETECTORS - ORBIS N N N N N N N N N N N N N N C 607-0289 Optical Smoke Detector C 607-0290 Multisensor C 607-0291 A1R (57°C) Rate of Rise Heat C 607-0292 A2S (57°C) Static Heat C 607-0293 BR (75°C) Rate of Rise Heat C 607-0294 BS (75°C) Static Heat C 607-0295 CR (90°C) Rate of Rise Heat C 607-0296 CS (90°C) Static Heat 608-0368 Air Sampling Unit 607-0297 Time Saver Base 607-0393 Deep Time Saver Base C 607-0298 Time Saver Diode Base C 607-0299 Time Saver Relay Base C 607-0300 Sav-Wire Base 607-0352 Orbis Adaptor NEW C NEW N C = Third Party Certified product 335 336 2-WIRE FIRE ALARM SYSTEMS (continued) Code RAFIKI TWINFLEX 2-WIRE 602-0009 Twinflex 2 wire 2 zone 602-0008 Twinflex 2 wire 4 zone 602-0007 Twinflex 2 wire 8 zone (Metal Box) 602-0004 Twinflex 2 wire 8 zone repeater 602-0045 Twinflex 2 wire 16 zone repeater TWINFLEX ANCILLARIES 602-0018 Twinflex-Multipoint c/w sounder 602-0017 Twinflex-Multipoint w/out sounder 602-0015 Twinflex callpoint 602-0013 Twinflex callpoint c/w sounder 602-0049 Twinflex callpoint Waterproof to IP55 615-0205 Twinflex callpoint keys (pack of 5) 602-0012 Twinflex Hatari sounder (red) 602-0011 Twinflex Hatari sounder (white) 602-0050 Twinflex Soundpoint Waterproof to IP55 602-0046 Twinflex Flashpoint sounder / Strobe (red/red) 602-0086 Twinflex Flashpoint sounder / Strobe (red/red) IP55 620-0486 Twinflex output module 602-0003 Rafiki metal panel bezel 602-0002 Rafiki optical chamber 602-0001 Rafiki head removal tool 2 WIRE ADDRESSABLE FIRE ALARM SYSTEMS RAFIKI 2-WIRE ADDRESSABLE 603-0006 Sita addressable single loop panel 603-0028 Sita Repeater Panel 603-0005 Sita addressable detector c/w sounder 603-0004 Sita addressable detector w/out sounder 602-0047 Sita Detector Base (Pack of 5) 603-0002 Sita addressable callpoint with Isolator 603-0029 Sita Callpoint Waterproof to IP55 603-0027 Sita Callpoint c/w sounder 603-0031 Sita Soundpoint Sounder Red 603-0032 Sita Soundpoint Sounder White 603-0030 Sita Soundpoint Sounder Waterproof to IP55 603-0026 Sita Hi-Point Horn 603-0025 Sita Flashpoint sounder / strobe 603-0017 Sita addressable input module 603-0018 Sita addressable output module 603-0019 Sita addressable Interface Relay Base V2 603-0020 Sita addressable Interface Relay Box V2 603-0007 Sit addressable Upload Lead 337 EXTINGUISHER PANELS Code C-TEC EP RANGE 3 ZONE AUTOMATIC EXTINGUISHER PANEL (TO EN12094-1) & ANCILLARIES • • • • • • • • • • • • • A new three-zone automatic extinguisher panel for areas housing expensive, dangerous or irreplaceable items of equipment Fully compliant with EN12094 part 1 Functions as a standard three zone fire panel with extra circuitry for controlling the release of fire-suppressing gas into computer rooms, chemical plants, etc. 128 x 64 pixel graphical display facilitates straightforward system programming Any combination of activated zones can be programmed to automatically start the panel’s release sequence Includes a front-panel mounted release button and two keyswitches for accessing the panel’s functions and toggling between automatic/ manual mode Three conventional sounder circuits, (two x 1st stage, one x 2nd stage) Wide range of monitored inputs and auxiliary outputs Abort and hold options allow the release sequence to be cancelled or suspended at any time Time-stamped event log Connections for up to eight remote status units with their own LCDs, manual release and mode switches Connections for up to eight economy status units also provided Optional relay expansion boards and single gang abort and hold buttons available ◆ NEW 620-0890 ◆ NEW 620-0902 ◆ NEW 620-0903 ◆ NEW 620-0904 ◆ ◆ EP203 3 zone EP automatic extinguisher panel (to EN12094-1) c/w 3A EN54-4 PSU & 128 x 64 pixel graphical LCD display EP212 Output expansion relay board for EP203, provides volt-free changeover relay contacts for reset, mode, discharged, hold and abort, Max. 8 x EP210F or EP210S per EP203 EP210F Remote status unit , flush mounting, fully-functional c/w Status LCD, manual release & mode (auto/manual) switches, Max. 8 x EP210F per EP203 EP210S Remote status unit, surface mounting, fully-functional c/w Status LCD, manual release & mode (auto/manual) switches, Max. 8 x EP210S per EP203 NEW 620-0881 BF359/1 Weatherproof enclosure, IP66, steel, non-locking (for EP210F/S) NEW 620-0891 EP211 Economy status unit, single gang c/w keyswitch operated mode (auto/manual) switch and Status LEDs. Max. 8 per EP203 ◆ NEW 620-0900 ◆ ◆ ◆ EP214 System line terminator (max. 2 per system) for terminating the EP203’s extinguishant release output to a gas release solenoid NEW 620-0905 NEW 620-0906 EP216 System abort button, single gang NEW 620-0907 BF372 Yellow extinguishant release call point, surface mounting 623-0398 BC286/2 24V 7.0 A Hr VRLA battery pack (2 x 12V including link wire) 338 EP215 System hold off button, single gang CDX RANGE NON-ADDRESSABLE FIRE DETECTORS Code N N N N N N HOCHIKI SMOKE DETECTORS C 607-0278 Optical Smoke Detector LPCB, available in white C 607-0279 Combined Heat Detector FT 60ºC (EN54 ClassA1/A1R), available in white C 607-0280 Combined Heat Detector FT 90ºC (EN54 Class C/CR), available in white C 607-0281 Fixed Temperature Heat Detector 60ºC (EN54 ClassA1/A1s), available in white C 607-0282 Fixed Temperature Heat Detector 90ºC (EN54 Class C/CS), available in white C 607-0160 Waterproof 60ºC Fixed Temperature Heat Detector 607-0283 Standard Conventional Mounting Base (No Diode), available in white 607-0284 Shottky Diode Detector Base, available in white 607-0285 2 Wire PA Base 607-0286 Latching Relay Base, available in white 607-0287 Latching Relay Base With Schottky Diode, available in white 607-0288 No Latching Relay Base, available in white N C = Third Party Certified product 339 APOLLO SERIES 65 NON-ADDRESSABLE FIRE DETECTORS Code N N N N N N N N APOLLO CONVENTIONAL DETECTORS - SERIES 65 C 607-0192 Optical smoke detector C 607-0193 Ionisation smoke detector C 607-0351 Integrating ionisation smoke detector C 607-0194 A1R (57°C) Rate of Rise Heat C 607-0195 BR (75°C) Rate of Rise Heat C 607-0196 CR (90°C) Rate of Rise Heat C 607-0197 CS (90°C) Static Heat 607-0011 Standard base 607-0012 Diode base 607-0216 Conduit Box 607-0182 E-Z fit 6" base 607-0205 Standard relay base 608-0185 MiniDisc remote indicator 618-0474 Series 65 Sounder Base with Diode C N C APOLLO CONVENTIONAL DETECTORS - ORBIS N N N N N N N N N N N N N N C 607-0289 Optical Smoke Detector C 607-0290 Multisensor C 607-0291 A1R (57°C) Rate of Rise Heat C 607-0292 A2S (57°C) Static Heat C 607-0293 BR (75°C) Rate of Rise Heat C 607-0294 BS (75°C) Static Heat C 607-0295 CR (90°C) Rate of Rise Heat C 607-0296 CS (90°C) Static Heat 608-0368 Air Sampling Unit 607-0297 Time Saver Base NEW C 607-0393 Deep Time Saver Base C 607-0298 Time Saver Diode Base C 607-0299 Time Saver Relay Base C 607-0300 Sav-Wire Base 607-0352 Orbis Adaptor NEW 340 N C = Third Party Certified product Code N N N N N N C 616-0049 The Fire Beam standard 5 to 40 m range C 616-0050 Mid range extension kit 40 to 80m C 616-0051 Long range extension kit 80 to 100m C 616-0052 Mount plate / adapter for beam head and single reflector - Unistrut friendly C C N C THE FIRE BEAM COMPANY HOCHIKI 608-0134 30 mtr Reflective Beam Detector 608-0135 Back Box for SRA-ET 621-0199 SPC-ET 100m beam detector set. Receiver and emitter type. Receiver requires zone connection. Emitter requires 24V aux supply = Third Party Certified product 341 Linear Beam Smoke Detectors LINEAR BEAM SMOKE DETECTORS LINEAR BEAM SMOKE DETECTORS (continued) Code Fire Fighting Enterprises N N NN N N NN 616-0014 FireRay 2000 End to End beam detector NEW 616-0037 Alignment Tool for Fireray 2000 C NEW 616-0045 Fireray 2000 EExd Beam Detector C 616-0022 FireRay 50R Reflective Beam detector - 50m Range C 616-0021 FireRay 100R Reflective Beam detector - 100m Range C NEW 616-0062 Surface Mount Wall Bracket for Fireray 50/100R Reflective Beam Detector Linear Beam Smoke Detectors C FIRERAY 2000 ALIGNMENT TOOL FIRERAY 2000 EEXD 342 N C = Third Party Certified product LINEAR BEAM SMOKE DETECTORS (continued) Code N N N C 616-0055 FireRay 5000 System (1 system controller, 1 detector, 1 prism) C 616-0056 FireRay 5000 Long Range Kit for distances between 50m & 100m C 616-0057 FireRay 5000 Universal Bracket N C = Third Party Certified product Linear Beam Smoke Detectors FIRERAY 5000 SYSTEM FIRERAY 50100R 343 F5000 UNIVERSAL BRACKET 344 N C = Third Party Certified product NON-ADDRESSABLE MANUAL CALL POINTS Code KAC Fire Call points N N N N N N N C 615-0003 Red indoor call point, Flush, 680 Ohm resistor C 615-0005 Red indoor call point, Surface, 680 Ohm resistor C 615-0118 Red indoor call point, Surface, 680 Ohm resistor, Re-settable C 615-0002 Red indoor call point, Flush, (No resistor) C 615-0004 Red indoor call point, Surface, (No resistor) C 615-0243 Red indoor call point, Surface, (No resistor) Re-settable C 615-0309 Red Outdoor Call Point, No resistor KAC COLOURED CALL POINTS N C 615-0094 White Call point, Surface, No resistor 615-0095 Yellow Call point, Surface, No resistor 615-0096 Blue Call point, Surface, No resistor 615-0001 Green Call point, Surface, No resistor 615-0099 Green call point, Surface, Double Pole, No resistor 615-0310 Surface mount, EXTERNAL Green break glass unit. IP67 (KAC) EDR marking KAC SPARES N C 615-0006 Spare Glass (pack 5) 620-0122 Flexible Element 620-0146 Continuity Links (pack of 5) 620-0121 Transparent hinge cover 615-0075 Test keys (pack of 10) 620-0213 Red Call point back box 615-0007 Flush Terminal Tray 615-0009 Surface terminal Box = Third Party Certified product 345 NON-ADDRESSABLE MANUAL CALL POINTS Code N C FULLEON 615-0100 615-0312 Fulleon Callpoint - Conventional Red, 470R (without back box) Fulleon CXL GP Universal Callpoint - High visibility LED alarm indicator, choice of connection for 470R or 680R resistors, fitted glass element, supplied resettable element with alarm flag, unique test/reset/cover removal key, back box with fixing screws. Red 615-0313 Fulleon CXL GP Universal Callpoint - High visibility LED alarm indicator, choice of connection for 470R or 680R resistors, fitted glass element, supplied resettable element with alarm flag, unique test/reset/cover removal key, back box with fixing screws, weather resistant - IP67. Red 615-0103 Fulleon Callpoint - Conventional Red, 470R, plastic resettable element (including backbox) 615-0247 Fulleon Callpoint - Conventional Green, plastic resettable element (including back box) 615-0244 Fulleon Callpoint Accessories - Standard Back Box (pack of 10) 615-0249 Fulleon Callpoint Accessories - Spacer (pack of 10) 615-0248 Fulleon Callpoint Accessories - Spacer Open Back (pack of 10) 615-0246 Fulleon Callpoint Accessories - Polycarbonate Cover (pack of 10) 615-0245 Fulleon Callpoint Accessories - Polycarbonate Cover Inc. Security Tie (pack of 10) 601-0558 Fulleon Callpoint Accessories - Resettable Element Conversion Kit (pack of 10) 346 615-0106 Fulleon Callpoint Accessories - Spare Glass (pack of 10) 615-0107 Fulleon Callpoint Accessories - Spare Key (pack of 10) N C = Third Party Certified product N C = Third Party Certified product 347 CQR FP3 NON-ADDRESSABLE MANUAL CALL POINTS (continued) Code CQR 615-0229 CQR FP3 Manual Callpoint complete with both frangible and resettable windows and high visibility LED, Resistor selection using jumpers. Complies with EN54-11 615-0230 Lift up cover for CQR FP3 Manual Call Point 615-0288 FP3/Glass (Pack of 5) 615-0264 FPE/Key STI Fire Call Points. Other colours available upon request N N N C 615-0338 RP-RF-01 ReSet Call Point EN54-11, Flush Mount C 615-0339 RP-RS-01 ReSet Call Point EN54-11, Surface Mount C 615-0340 WRP-R-01 IP67 Waterproof ReSet Call Point VIMPEX N N C 615-0242 Resettable Call Point, Flush Mount C 615-0241 Resettable Call Point, Surface Mount Also available in Green, Blue, Yellow and white N Non-Addressable Manual Call Points NEW 615-0337 Waterproof Resettable Callpoint, Surface Mount, IP66 348 N C = Third Party Certified product INTRUDER PANEL FIRE DETECTORS Code TEXECOM Exodus OH/4W (5 Year Warranty) EN54 certified 12V optical heat-enhanced smoke detector for use with security control panels. Heat enhancement ensures high sensitivity to fast burning fires whilst optical chamber provides exceptional false alarm immunity. BSI Kitemark approved to EN54 part 7. Features include: Microprocessor technology, latch input, built-in relay, drift compensation and chamber test facility. Complete with complimentary connector base. 609-0090 Exodus FT64/4W (5 Year Warranty) EN54 certified 12V fixed 64° C heat detector for use with security control panels. Suitable for environments where smoke or dust is prevalent. Superior false alarm immunity. BSI Kitemark approved to EN54 part 5. Features include: Microprocessor technology, latch input, built-in relay and thermistor test facility. Complete with complimentary connector base. 609-0091 Exodus FT90/4W (5 Year Warranty) EN54 certified 12V fixed 90° C heat detector for use with security control panels. Suitable for environments where smoke or dust is prevalent. Ideal for extreme ambient temperature conditions. BSI Kitemark approved to EN54 part 5. Features include: Microprocessor technology, latch input, built-in relay and thermistor test facility. Complete with complimentary connector base. 609-0092 Exodus RR/4W (5 Year Warranty) EN54 certified 12V rate of rise heat detector for use with security control panels. Suitable for environments where smoke or dust is prevalent. Excellent detection performance even at low ambient temperatures. BSI Kitemark approved to EN54 part 5. Features include: Microprocessor technology, latch input, built-in relay and thermistor test facility. Complete with complimentary connector base. DOMESTIC FIRE DETECTORS SENSOTEC 609-0053 4800 9v Ionisation 609-0052 4900 9v Optical 609-0050 4870 230v Ionisation (c/w battery back-up) 609-0064 4973 230v Optical (c/w battery back-up) 609-0068 4899 230v Heat (c/w battery back-up) 607-0166 4890 Surface Pattress 607-0167 4891 Relay Base C/O DETECTORS SENSOTEC 620-0396 4CB 4.5V Battery Detector 610-0030 4CMBi Mains detector plus interlink and battery back-up 610-0032 4CMBiR Mains detector plus interlink, battery back-up and relay 349 Intruder Panel/Domestic Detectors 609-0088 DETECTOR TEST EQUIPMENT Code DETECTOR TESTERS HANDHELD AEROSOLS 612-0002 N N C C “Canned Smoke” - 150ml, Non-flammable Smoke Aerosol for hand-held use 612-0068 Chekkit Smoke Aerosol Smoke detector Tester, Non-flammable, 150ml Smoke Aerosol for hand-held use 612-0069 Chekkit Smoke Aerosol Smoke detector Tester, Non-flammable, 35ml Smoke Aerosol for hand-held use SOLO AEROSOLS N C 612-0031 SOLO Smoke Detector Tester - 250ml, Non-flammable, Smoke Aerosol (for use with SOLO330 Dispenser and SOLO Test Kits) 612-0037 SOLO Carbon Monoxide (CO) Test Gas - 4Ltr compressed gas. Non-flammable. (For Testing of CO Fire Detectors. Must be used with SOLO330 dispenser) 612-0054 SOLO “Detector Duster” - 250ml, Non-flammable, Compressed Air Spray SOLO TOOLS 612-0021 SOLO100 4-Section, Fibreglass Telescopic Pole (6Mtr reach) 612-0055 SOLO108 2-Section, Fibreglass Telescopic Pole (4Mtr reach) 612-0027 SOLO101 1-Piece Fibreglass Extension Pole (2.5Mtr reach) 620-0177 N C SOLO200 Universal, Detector Head Removal and Replacement (Inspection) Tool 612-0034 SOLO330 Smoke/CO Dispenser (for use with SOLOA3 Smoke Aerosol or SOLOC3 CO Test Gas) 612-0040 SOLO423 Heat Detector Tester - Mains 110/120v, c/w 5 Mtr Cable 612-0033 SOLO424 Heat Detector Tester - Mains 220/240v, c/w 5 Mtr Cable N C 612-0059 SOLO425 Extra 5Mtr Extension Cable Assembly 612-0028 SOLO461 Cordless Heat Detector Test Kit (c/w 2 x Battery Batons and Charger) 612-0022 SOLO610 2-Part, Padded Carry/Storage Bag System SOLO KITS 612-0060 SOLO808 Smoke Test ‘Starter Pack’, excl. Bag (4 Mtr reach) 612-0061 SOLO809 Smoke Test ‘Starter Pack’, excl. Bag (6 Mtr reach) 612-0018 SOLO811 Smoke Detector Test and Inspection Kit, incl. Bag (6 Mtr reach) 612-0016 SOLO814 Smoke and Mains Heat Detector Test and Inspection Kit (6 Mtr reach) 612-0035 SOLO822 Smoke and Cordless Heat, Detector Test and Inspection Kit (6 Mtr reach) 612-0036 SOLO823 Smoke and Cordless Heat, Detector Test and Inspection Kit (9 Mtr reach) TESTIFIRE TOOLS • World’s first multi-stimulus detector tester for Smoke, Heat and CO fire detectors • Suitable for use on Smoke, Heat, CO, Multi Sensor, Conventional, Addressable and Intelligent detectors • Testing with one tool is faster and more productive • Smoke, Heat and CO tests are delivered individually or for the first time simultaneously in whichever combination is required Please Contact the Technical Department for further information on this range. 350 N C = Third Party Certified product Code BT REDCARE FIRE STU’S 620-0535 Firestu.com 3 Pin Firestu in Boxed PSU (Redcare Ready) 620-0045 3G 8 Pin Stu - Stand Alone 351 Redcare Fire Stu’s BT REDCARE 24V FIRE STU’S ANCILLARY FIRE PRODUCTS ANCILLARY FIRE PRODUCTS Code Code C-TEC Ancillaries Door Retainers 601-0181 FF502P Universal four zone sounder circuit extender kit 623-0257 BF376 24V 5A polarised relay on a single gang plate VIMPEX - Remote Indicator N N NFULLEON - Door Retainers NEW 620-0924 Vimpex LED Remote Indicator, flush, white NEW 620-0928 Vimpex LED Remote Indicator, surface, white NEW 620-0929 Mounting Box, White 620-0400 BF318 Remote LED indicator on a single gang plate 620-0399 BF367 Keyswitch operated device isolator on a single gang plate 620-0398 BF366 Keyswitch isolatable 24V 5A relay on a single gang plate 601-0648 BF365SC Sounder isolator controller, supplied on a double gang plate 620-0504 Wall Mounted Magnetic Door Release 24V dc 620-0528 Wall Mounted Magnetic Door Release 230V ac BF365IM Sounder isolator module (Max. 35 per BF365SC) CUSTOM - Door Retainers/Closers 601-0649 C-TEC Fire door retainers 621-0051 CRANFORD CONTROLS - Door Retainers 620-0634 DRW-L Low Profile Door Retainer 24V dc c/w Keeper Plate 620-0637 24V dc 500N Low Profile Retainer c/w keeper Plate MDR-025 24 V.d.c Magnetic Door Retainer C/W Keeper Plate 620-0759 MDR-026 240 V.a.c. Magnetic Door Retainer C/W Keeper Plate 620-0465 MDR-003 Floor Mounting Bracket for above Retainers 620-0245 MDH-613 24 V.d.c Overhead Door Closer (Hold Open) 620-0244 MDH-623 24 V.d.c Overhead Door Closer (Hold Open Swing Free) 620-0635 DRW-M Low Profile Door Retainer 230V dc c/w Keeper Plate 620-0636 FMB-04 Floor Mounting Bracket for Door Retainer 620-0390 KP-02 Universal Keeper Plate 620-0223 DRF-C Chain & Keeper Plate with 1 Metre of chain 620-0530 DRX-200 Floor Mounted Door Retainer 24V dc 200N c/w keeper Plate 621-0121 REM-003 Remote Indicator with “Fire Alarm Detector Operated” Text - 5mm 620-0705 DRX-500 Floor Mounted Door Retainer 24V dc 500N c/w keeper Plate 620-0783 REM-023 Remote LED Indicator/Buzzer Unit 620-0784 REM-024 Remote LED Indicator/Buzzer Unit C/W Keyswitch 620-0706 DRP-L500 24V Door Retainer on a pole - Swivel head 283/350mm 500-750 N CUSTOM - Auxiliary Relay Devices 620-0707 DRP-L1000 24V Door Retainer on a pole - Swivel head 283/350mm 1000-1300 N 621-0118 REL-001 24 Volt 5 Amp d.c. Resistive Load (PCB only) 621-0119 REL-002 24 Volt 5 Amp d.c. Resistive Load in IP65 ABS enclosure DRP-S500 24V Door Retainer on a pole - Swivel head 183/250mm 500-750 N 621-0120 REL-004 24 Volt 5 Amp d.c. Relay on Single Gang Plate 620-0708 Ancillary Fire Products 620-0758 BF375PK Door retainer kit c/w 250mA PSU & 1 door holder CUSTOM - Remote Indicators Dual voltage 24V & 2.5V Red LED N N N N VIMPEX Heavy Duty Door Retainers 620-0709 DRP-S1000 24V Door Retainer on a pole - Swivel head 183/250mm 1000-1300 N 620-0788 24V dc Decorative Door Retainer - Chrome 620-0789 24Vdc Decorative Door Retainer - Chrome/Switch 620-0790 Chrome Mounting Kit 620-0791 24V dc Decorative Door Retainer - Brass 620-0792 24Vdc Decorative Door Retainer - Brass/Switch 620-0793 Brass Mounting Kit FIRE EXTINGUISHERS 620-0910 IP65 24V dc Door Retainer - 1200N THOMAS GLOVER NEW 620-0911 DRW-L-M - Low Profile Metal Door Retainer - 24V dc - 200N NEW 620-0912 DRX-200 VP - Vandal Proof Floor Mounted Door Retainer - 200N NEW 620-0913 DRX-500 VP - Vandal Proof Floor Mounted Door Retainer - 500N 620-0785 RIU-01 Remote Indicator without text 620-0786 RIU-01B Remote Indicator without text - Deep Back Box 620-0003 RIU-02 Square Indicator c/w ‘’Fire Detector Operated’’ text 620-0419 RIU-02B Square Indicator as above with Deep Back Box 620-0242 RIU-06 Circular Indicator without text C 620-0886 Door retainer wall mount 24Vdc, 200N, extra strong housing C 620-0888 Door retainer 230Vac, 200N, extra strong housing C 620-0887 Anti -Vandal Floor Mounting Door Retainer C 620-0714 Heavy duty wall mounted door retainer in aluminium casting 400N, 24Vdc Also available - Floor mount extension poles and Chrome/Brass Finishes N N NCRANFORD CONTROLS - Remote Indicators 613-0071 2.0kG CO2 with Swivel Horn 613-0037 9Ltr Water 613-0026 1kG Dry Powder 613-0003 2Kg Dry Powder 613-0072 4Kg Dry Powder 613-0055 6Kg Dry Powder 613-0038 6Ltr Foam 613-0032 9Ltr Foam CRANFORD CONTROLS - Auxiliary Relays FIRE BLANKETS 620-0420 RIU-R24B 24V dc Auxiliary dual relay in single gang housing THOMAS GLOVER 620-0421 R24-PCB 24V dc Auxiliiary dual relay PCB only 614-0006 620-0336 R24-BOX 24V dc Auxiliary dual relay in metal enclosure 1m x 1m PVC rigid pack INTERFACE SOLUTIONS - Auxiliary Relays N N N NEW 620-0914 24V (2 Amp) Mini Transistorised Double Pole Relay (Single Unit) ISM24T NEW 620-0915 24V (2 Amp) Mini Double Pole Polarised Relay (Single Unit) ISM24 NEW 620-0916 24V Induced AC/Spike Filter IS24F 352 N C = Third Party Certified product WATER LEAKAGE DETECTION SYSTEM Code VIMPEX Single Zone Control Panel (ABS enclosure) 624-0003 2 Zone Control Panel (ABS enclosure) 624-0004 4 Zone Control Panel (ABS enclosure) 624-0005 6 Zone Control Panel (ABS enclosure) 624-0027 2 Zone Control Panel 624-0026 2 Zone Flush Control Panel 624-0025 4 Zone Control Panel 624-0024 4 Zone Flush Control Panel 624-0012 8 Zone Control Panel 624-0013 8 Zone Flush Control Panel 624-0014 12 Zone Control Panel 624-0015 12 Zone Flush Control Panel 624-0023 16 Zone Control Panel 624-0022 16 Zone Flush Control Panel 624-0021 24 Zone Control Panel 624-0020 24 Zone Flush Control Panel 624-0006 Floor Mounted Probe 624-0030 Floor Mounted Probe supplied with protective cage (steel web) and spacer 624-0007 Drip Tray Mounted Probe 624-0019 Remote Lamp Unit “Water Alarm” 624-0008 Hydrowire (Water Detection Cable) 5m length 624-0018 Hydrowire (Water Detection Cable) 10m length 624-0009 Connection Box 624-0010 End of Line Plug 624-0011 Leader Cable (50m) 624-0017 Pack of Fixing Clips for Leader and Hydrowire Cable (100) 353 Water Leakage Detection System 624-0002 ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANELS Code C-TEC XFP NETWORKABLE RANGE (LPCB Approved to EN54 parts 2/4) • • • • • • • • • • • • • • Single loop 16 zone and one and two loop 32 zone versions available Compatible with Hochiki and Apollo (XP95/Discovery) protocols Up to 32 network nodes (can comprise multiple master and repeater panels) Two independently programmable conventional sounder circuits Alert, Reset, Silence and ‘Class Change’ inputs Day and Night (building occupied/unoccupied) function Investigation delay period function Individual sensitivity settings for each device Zone dependency (coincidence) function Phased Evacuation facility Alarm Counter Intuitive Windows based PC upload-download programming software Third-party certificated to EN54-2/4 by the LPCB Fully compatible with C-TEC’s new Hush Button fire alarm solution for Houses of Multiple Occupation (HMOs) N N N N N N XFP NETWORKABLE FIRE PANELS (XP95/Discovery protocol) N N N N N N XFP NETWORKABLE FIRE PANELS (Hochiki protocol) C 604-0297 XFP Networkable single loop 16 zone panel (XP95/Discovery), code entry, c/w 1.4A psu, plastic lid, plastic back box C 604-0296 XFP Networkable single loop 16 zone panel (XP95/Discovery), keyswitch entry, c/w 1.4A psu, plastic lid, plastic back box C 604-0301 XFP Networkable one loop 32 zone panel (XP95/Discovery), code entry, c/w 3A psu, plastic lid, metal back box C 604-0300 XFP Networkable one loop 32 zone panel (XP95/Discovery), keyswitch entry, c/w 3A psu, plastic lid, metal back box C 604-0305 XFP Networkable two loop 32 zone panel (XP95/Discovery), code entry, c/w 3A psu, plastic lid, metal back box C 604-0304 XFP Networkable two loop 32 zone panel (XP95/Discovery), keyswitch entry, c/w 3A psu, plastic lid, metal back box C 604-0308 XFP Networkable single loop 16 zone panel (Hochiki), code entry, c/w 1.4A psu, plastic lid, plastic back box C 604-0295 XFP Networkable single loop 16 zone panel (Hochiki), keyswitch entry, c/w 1.4A psu, plastic lid, plastic back box C 604-0298 XFP Networkable one loop 32 zone panel (Hochiki), code entry, c/w 3A psu, plastic lid, metal back box C 604-0299 XFP Networkable one loop 32 zone panel (Hochiki), keyswitch entry, c/w 3A psu, plastic lid, metal back box C 604-0302 XFP Networkable two loop 32 zone panel (Hochiki), code entry, c/w 3A psu, plastic lid, metal back box C 604-0303 XFP Networkable two loop 32 zone panel (Hochiki), keyswitch entry, c/w 3A psu, plastic lid, metal back box XFP ANCILLARIES (repeaters, network cards, printers and software) N N N N NEW 604-0538 NEW v604-0539 XFP510-16 Networkable repeater panel, 16 zones (all protocols), code entry, c/w psu, plastic enclosure XFP 510-16K Networkable repeater panel, 16 zones (all protocols), keyswitch entry, c/w psu, plastic enclosure NEW 604-0540 XFP510-32 Networkable repeater panel, 32 zones (all protocols), code entry, c/w psu, plastic lid, metal back box NEW 604-0541 XFP 510-32K Networkable repeater panel, 32 zones (all protocols), keyswitch entry, c/w psu, plastic lid, metal back box 601-0395 XFP network communications card for XFP 16 zone panels (all protocols, one required per master panel) 604-0070 XFP network communications card for XFP 32 zone panels (all protocols, one required per master panel) 604-0167 Flush mounting bezel (for XFP 32 zone master & repeater panels) 604-0166 XFP printer kit, including printer, lead and socket 604-0306 XFP Upload download software (Windows 2000/XP) c/w lead 604-0486 2m programming lead only BS 5839 PART 6 HUSH BUTTONS C-TEC BS 5839 PART 6 HUSH BUTTON SOLUTION FOR HOUSES OF MULTIPLE OCCUPATION • • • • N N A new BS 5839-6 compliant fire alarm solution for houses of multiple occupation (HMOs) Designed to sit on an Apollo or Hochiki analogue addressable loop Each Hush Button has its own conventional detector circuit, conventional sounder circuit and onboard loop isolator Provides each HMO dwelling with a two-minute silence facility and 15-minute isolate facility (to BS 5839-6 clause 12.2) NEW 604-0553 XFP508H BS 5839-6 Hush Button (Hochiki ESP) NEW 604-0554 XFP508X BS 5839-6 Hush Button (Apollo XP95/Discovery/Xplorer) 354 N C = Third Party Certified product ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANELS (continued) Code ADVANCED ELECTRONICS MX-4000 RANGE Approved to BS EN 54 parts 2 & 4 N N N N N C 604-0097 Mx-4100 Single loop 100 Zone (Apollo/Hochiki) c/w 2 loops C 604-0104 Mx-4201 2 loop 200 zone panel (Apollo/Hochiki) c/w 1 loop C 604-0103 Mx-4401 4 loop 200 zone panel (Apollo/Hochiki) c/w 1 loop C 604-0281 MX-4802 8 loop 200 zone panel (Apollo/Hochiki) c/w 2 loops C 604-0108 Loop driver card (Apollo/Hochiki) for Mx-4201/Mx-4401 or Mx-4802 604-0120 Mxp-012 On-board printer for Mx-4200/4400/4800 604-0106 Mxp-011 Key access enable keyswitch assembly MX-4000 ZONAL LED CARDS N N N N N C 604-0285 Mxp-024 20 Zone LED card for Mx-4100 C 604-0286 Mxp-025 20 Zone LED card for Mx-4201/4401/4802 C 604-0116 Mxp-013-050 50 zone LED card for Mx-4201/4401/4802 C 604-0117 Mxp-013-100 100 zone LED card for Mx-4201/4401/4802 C 604-0283 Mxp-013-200 200 zone LED card for Mx-4201/4401/4802 MX-4000 EXPANSION MODULES 604-0115 Mxp-008 8-way programmable relay output card for Mx-4200 /4400 /4800 604-0118 Mxp-014 8-way programmable input card 604-0289 Mxp-029 Shop Interface Unit (input/output card) 604-0259 Mxp-021 4-way sounder splitter card 604-0284 Mxp-021-BXP 4-way sounder splitter with 4A PSU (Boxed) 604-0287 Mxp-026-BXP 4 Amp Sounder Booster Card with 4 Amp PSU (boxed) 604-0293 Mxp-028 Modem card (24V) 604-0288 Mxp-028-BX Modem card (24V) boxed MX-4000 FLUSHING KITS 604-0099 Mxm-001 Semi-flushing bezel for Mx-4100 604-0098 Mxm-002 Semi-flushing bezel for Mx-4201/Mx-4401 604-0260 Mxm-008 Semi-flushing bezel for Mx-4010/Mx-4020 604-0282 Mxm-032 Semi-flushing bezel for Mx-4802 604-0454 Mxm-007 Perspex door kit for Mx-4201/Mx-4401 MX-4000 REMOTE TERMINALS 604-0110 (RDT) Remote Display Terminal, standard network interface, 24V dc 604-0109 (RCT) Remote Control Terminal, standard network interface, 24V dc 604-0292 Remote Display Terminal with fault-tolerant network interface, 24V dc 604-0280 Remote Control Terminal with fault-tolerant network interface, 24V dc AD-NET NETWORKING N N C 604-0107 Mxp-003 Standard Network Card C 604-0270 Mxp-009 Fault Tolerant Network Card 604-0224 Graphics Interface Boxed (24V) 604-0462 Graphics Interface Boxed with fault-tolerant network interface (24V) MX-4000 PC-NET SOFTWARE 604-0100 Pc-NeT-03 Mx configuration software & lead 604-0290 PC-NeT-03-USB Mx configuration software & USB upload/ download lead 604-0291 Pc-NeT-04 Mx-4000 series remote dial-up software upload/ download lead (Virtual Panel) See Across Mx Graphical Control software requires Mxp-010 graphical interface 604-0279 Pc-NeT-07 Mx-4000 series logo programming software MX-4000 PERIPHERALS 604-0455 Mxp-048 Portable Re-chargeable Printer C 604-0456 24V 1.5A EN54-4 Approved Power supply/charger boxed C 604-0457 24V 3A EN54-4 Approved Power supply/charger boxed C 604-0458 24V 5A EN54-4 Approved Power supply/charger boxed 604-0500 ESPA Pager Interface Card C 604-0501 Peripheral Bus Interface Card C 604-0502 Peripheral Bus - EN54-2 Certified Fire/Fault Routing Card 604-0503 Peripheral Bus - 4-Way Sounder Card 604-0504 Peripheral Bus - 4-Way Sounder with 4A PSU (Boxed) NEW 604-0560 Peripheral Bus - 4-way relay card NEW 604-0561 Peripheral Bus - 4-way relay card with 1.5A PSU (Boxed) N N N N N N N N C = Third Party Certified product 355 MORLEY IAS ZX RANGE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANELS (continued) Code MORLEY IAS “ZX” SERIES N N N N 604-0113 ZX2e 1-2 Loop base panel (expandable to 2 loops, networkable), 20 zones 604-0563 ZX2Se 1-2 Loop base panel 4 line LCD, 460mA/loop capability (expandable to 2 loops, networkable), 20 zones C 604-0111 ZX5e 1-5 Loop base panel (expandable to 5 loops, networkable), 20 zones fitted expands to 80 zones C 604-0494 ZX5Se 1-5 Loop base panel 4 line LCD, 460mA/loop capability (expands to 5 loops networkable), 20 zones fitted expands to 80 zones C NEW 604-0112 ZX1e Single Loop base panel, 20 zones (networkable) 604-0562 ZX1Se Single Loop base panel 4 line LCD, 460mA/loop capability, 20 zones (networkable) 604-0023 RS485 Plug in communications/network card 604-0024 RS232 Plug in communications card 604-0041 4 Way relay card 604-0042 4 Way sounder card 604-0040 Boxed 3 amp PSU/charger/sounder booster unit 604-0034 8 Way serial input card N NEW 356 608-0115 HI485 High integrity communications/network card 604-0265 Visualeyez graphics workstation software - basic edition. For connection to a stand alone panel. Pc based mimic panel. 604-0266 Visualeyez graphics workstation software - standard edition. For connection to a single network with up to 9 panels. 604-0267 Visualeyez graphics workstation software - standard edition. For connection to a single network with up to 99 panels. 604-0020 Loop driver card Nittan protocol 604-0168 RS485/232 Converter 604-0029 Loop driver Apollo S90/XP95 protocol 604-0030 Integral printer for ZX5E 604-0170 Modbus interface 604-0125 Loop driver card Hochiki protocol 604-0497 MKII Loop driver card Hochiki protocol, 460mA 604-0171 Boxed remote printer 230v 612-0038 Boxed 5 amp power supply 604-0172 5 amp psu chassis mounted 604-0173 Mimic driver card 604-0064 Loop driver Apollo XP95/Discovery protocol 604-0495 MKII Loop Driver Apollo XP95/Discovery protocol, 460mA 604-0174 Boxed peripheral pager unit 604-0065 Loop driver card system sensor protocol 604-0498 MKII Loop driver card system sensor protocol 460mA 604-0175 Loop driver card Morley – IAS protocol 604-0127 20 zone expander PCB for ZX5E 604-0126 60 zone expander PCB for ZX5E N C = Third Party Certified product MORLEY IAS DX RANGE ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANELS (continued) Code 604-0176 Interface Lead for Morley panels 9 way D-TYP>4 way PLG 604-0548 USB to RS232 converter (upload/download lead serial port to USB converter) 604-0177 Dongle, fire 6 dial-up s/ware 604-0178 Engineers software programming kit CD 620-0371 Printer ribbon + paper (for ZX5E Integral printer) 620-0349 Thermal printer paper (for boxed remote printer) 604-0434 ZX1e/2e Battery box, 400x400x135 N NEW 604-0435 ZX5e Battery box, 500x500x185 604-0436 L’ shaped bracket suitable for mounting peripheral pcb within Zxe/Z/X5e 604-0124 ZX1e/2e Flush mounting bezel 604-0123 ZX5e Flush mounting bezel 620-0366 ZX1e/2e Glass/inner door kit 620-0282 ZX5e Glass/inner door kit 604-0134 ZXr-A Base active repeater 604-0133 ZXr-P Base passive repeater 604-0132 Bezel for ZXr-A/ZXr-P repeaters, semi-flush mounting NEW 604-0564 Stainless Steel Active Repeater NEW 604-0565 Stainless Steel Passive Repeater C 604-0159 DX1e-20S 1 Loop panel C 604-0181 DX1e-40M 1 Loop panel C 604-0163 DX2e-40M 2 Loop panel C 604-0164 DX4e-40L 4 Loop panel 604-0196 Bezel kit, dimension DXS 604-0197 Bezel kit, dimension DXM 604-0198 Bezel kit, dimension DXL 604-0199 DXM control panel cover with printer slot 604-0268 DX Glass door kit (for M & L enclosures) 604-0269 DX Glass door kit (for M & L enclosures with printer) NEW 604-0566 DX-S stainless steel bezel and door kit with printer slot NEW 604-0567 DX-M stainless steel bezel and door kit with printer slot NEW 604-0568 DX-L stainless steel bezel and door kit with printer slot NEW 604-0569 DX-S battery box or mounting enclosure, 245 x 380 x 110 NEW 604-0570 DX-M battery box or mounting enclosure, 380 x 380 x 130 N NMORLEY IAS “DIMENSION” N N N N N N N N N N 604-0176 Interface Lead for Morley panels 9 way D-TYP>4 way PLG 604-0548 USB to RS232 converter (upload/download lead serial port to USB converter) 604-0178 Engineers software programming kit CD 604-0179 Kit, DX Keyswitch 604-0180 Kit, DX Printer 604-0134 ZXr-A Base active repeater 604-0133 ZXr-P Base passive repeater 604-0132 Bezel for ZXr-A/ZXr-P repeaters, semi-flush mounting NEW 604-0564 Stainless Steel Active Repeater NEW 604-0565 Stainless Steel Passive Repeater NEW N N N C = Third Party Certified product 357 ANALOGUE ADDRESSABLE FIRE ALARM CONTROL PANELS (continued) Code N N N C C C N N N C C C KENTEC Syncro AS Control Panels - Hochiki Protocol 604-0510 604-0511 604-0512 604-0574 604-0575 Single Loop Hochiki Syncro AS Lite C/P (16 Zone Leds, Surface) Single Loop Hochiki Syncro AS C/P (16 Zone Leds, Surface) Single Loop Hochiki Syncro AS C/P with printer (16 Zone Leds, Surface) 2 Loop Hochiki Syncro AS C/P (16 Zone Leds, Surface) 2 Loop Hochiki Syncro AS C/P with printer (16 Zone Leds, Surface) Syncro AS Control Panels - Apollo Protocol 604-0489 604-0513 604-0514 604-0576 604-0577 Single Loop Apollo Syncro AS Lite C/P (16 Zone Leds, Surface) Single Loop Apollo Syncro AS C/P (16 Zone Leds, Surface) Single Loop Apollo Syncro AS C/P with printer (16 Zone Leds, Surface) 2 Loop Apollo Syncro AS C/P (16 Zone Leds, Surface) 2 Loop Apollo Syncro AS C/P with printer (16 Zone Leds, Surface) Syncro Control Panels - Hochiki Protocol N N N N N N N N N N N N N N N N N N N N N N N N N N N N N N C C C C C C C C C C C C C C C C C C C C C C C C C C C C C C 604-0359 604-0360 604-0361 604-0362 604-0363 604-0364 604-0365 604-0366 604-0367 604-0368 604-0369 604-0370 604-0371 Syncro Control Panels - Apollo Protocol 604-0372 604-0373 604-0374 604-0375 604-0376 604-0377 604-0378 604-0379 604-0380 604-0381 604-0382 604-0383 604-0384 2 Loop Apollo Syncro Lite C/P (16 Zone Leds, Surface) 2 Loop Apollo Syncro C/P (16 Zone Leds, Surface) 2 Loop Apollo Syncro C/P (16 Zone Leds, Surface c/w Printer) 2 Loop Apollo Syncro C/P (48 Zone Leds, Surface) 2 Loop Apollo Syncro C/P (48 Zone Leds, Surface c/w Printer) 2 Loop Apollo Syncro C/P (96 Zone Leds, Surface) 2 Loop Apollo Syncro C/P (96 Zone Leds, Surface c/w Printer) 4 Loop Apollo Syncro C/P (16 Zone Leds, Surface) 4 Loop Apollo Syncro C/P (16 Zone Leds, Surface c/w Printer) 4 Loop Apollo Syncro C/P (48 Zone Leds, Surface) 4 Loop Apollo Syncro C/P (48 Zone Leds, Surface c/w Printer) 4 Loop Apollo Syncro C/P (96 Zone Leds, Surface) 4 Loop Apollo Syncro C/P (96 Zone Leds, Surface c/w Printer) Syncro GUIDE - PC Graphics Packages 604-0385 604-0386 604-0387 604-0388 604-0389 604-0390 Single Panel Package 4 Panel Package 8 Panel Package 16 Panel Package 32 Panel Package 64 Panel Package Syncro Focus - Network LCD Repeaters 604-0397 604-0398 604-0399 604-0400 Public Address Systems 2 Loop Hochiki Syncro Lite C/P (16 Zone Leds, Surface) 2 Loop Hochiki Syncro C/P (16 Zone Leds, Surface) 2 Loop Hochiki Syncro C/P (16 Zone Leds, Surface c/w Printer) 2 Loop Hochiki Syncro C/P (48 Zone Leds, Surface) 2 Loop Hochiki Syncro C/P (48 Zone Leds, Surface c/w Printer) 2 Loop Hochiki Syncro C/P (96 Zone Leds, Surface) 2 Loop Hochiki Syncro C/P (96 Zone Leds, Surface c/w Printer) 4 Loop Hochiki Syncro C/P (16 Zone Leds, Surface) 4 Loop Hochiki Syncro C/P (16 Zone Leds, Surface c/w Printer) 4 Loop Hochiki Syncro C/P (48 Zone Leds, Surface) 4 Loop Hochiki Syncro C/P (48 Zone Leds, Surface c/w Printer) 4 Loop Hochiki Syncro C/P (96 Zone Leds, Surface) 4 Loop Hochiki Syncro C/P (96 Zone Leds, Surface c/w Printer) Syncro Focus with power supply Syncro Focus less power supply Syncro Focus Plus with controls & with power supply Syncro Focus plus with controls less power supply Syncro View - Serial LCD Repeaters 604-0401 604-0508 604-0402 604-0509 Syncro View with power supply Syncro View with power supply, c/w enable control k/switch Syncro View less power supply Syncro View less power supply, c/w enable control k/switch Syncro I/O Boards & Enclosures 604-0403 604-0404 604-0405 604-0406 604-0407 604-0408 604-0409 604-0410 Syncro I/O - 4 Way Conventional interface Syncro I/O - 6 Way Sounder card Syncro I/O - 8 Way Programmable relay card Syncro I/O - 16 Channel I/O card Syncro I/O module enclosure (Fits 3No Syncro I/O Modules) Syncro I/O module enclosure c/w 750mA PSU (Fits 2No Syncro I/O Modules) Syncro I/O module enclosure c/w 2.5A PSU (Fits 2No Syncro I/O Modules) Syncro I/O module enclosure c/w 4A PSU (Fits 2No Syncro I/O Modules) Syncro Ancillary Items 604-0411 604-0412 604-0413 604-0414 604-0443 358 Syncro Network Interface card Apollo 2 Loop extender board Hochiki 2 Loop extender board Syncro panel printer assembly Standard software download lead (All panels) N C = Third Party Certified product HOCHIKI ESP RANGE ANALOGUE ADDRESSABLE FIRE DETECTORS Code HOCHIKI N N N N N N C 608-0072 Optical Smoke Sensor, also available in white C 608-0190 Optical Smoke Sensor (Black) C 608-0191 Multi Sensor Optical/Heat, also available in white C 608-0073 Ionisation Smoke Sensor C 608-0290 Multi-Heat Sensor, also available in white C 608-0291 Weather Proof Multi-criteria IP67 Heat Sensor 608-0075 Standard Sensor Base, also available in white 608-0189 Standard Sensor Base (Black) 608-0133 Short Circuit Isolator Base, also available in white 618-0496 Isolator and sounder base and sounder base beacon blanking cover N N 615-0297 Addressable manual call point, flush mounting 615-0009 Surface mounting back box for use with HCP-E manual call point 615-0298 Addressable weatherproof manual point C 618-0495 Loop powered sounder base, also available in white C 618-0498 Loop powered red wall mounted sounder, also available in white 618-0499 Wall sounder weather proofing kit N C 608-0309 (RED) wall sounder mounting base, red, also available in white 608-0310 (RED) wall sounder mounting base, red, complete with loop isolator, also available in white 618-0573 Loop powered sounder base beacon, also available in white 619-0111 Addressable Loop Powered Flashing Beacon, RED, other colours available N NEW 620-0394 Addressable loop powered remote indicator, clear lens with red LED indication 608-0071 Hand Held Address Programmer INTERFACES 608-0130 Dual zone monitor (requires local 24vdc) unboxed, LPCB approved NEW 608-0320 Dual sounder circuit controller, c/w loop isolator, requires local 24V DC supply (unboxed) NEW 608-0322 Single zone monitor, c/w loop isolator, loop powered (unboxed) NEW 608-0324 Dual relay controller, c/w loop isolator, loop powered (unboxed) NEW 608-0326 Dual input module, c/w loop isolator, loop powered (unboxed) NEW 608-0328 Mains relay controller, relay rated at 240V AC, 5Amp resistive load maximum, c/w loop isolator NEW 608-0329 Loop powered, powered output module NEW 608-0341 Back box for use with all the above listed interface modules NEW 608-0342 White box lid for use with new modules NEW 608-0343 Adaptor plate. Adaptor for use with all new modules, allows retrofitting of new modules into old style module back box Public Address Systems N N N N N N N N N N C DIN RAIL MOUNTING INTERFACES N N N N N NEW 608-0331 Dual Input Module c/w Isolator NEW 608-0333 Dual Relay Controller c/w Isolator NEW 608-0335 Single Zone Monitor c/w Isolator NEW 608-0337 Dual Sounder Controller c/w Isolator NEW 608-0339 Mains Relay Controller c/w Isolator 608-0340 Short Circuit Loop Isolator N C = Third Party Certified product 359 ADDRESSABLE FIRE DETECTORS (continued) Code APOLLO INTELLIGENT XP95 FIRE DETECTORS N N N N N N N N N C 608-0003 Ionisation Smoke C 608-0004 Optical Smoke C 608-0005 Standard Heat (55ºC) C 608-0048 High Temperature Heat (90ºC) C 608-0107 Multisensor NEW 608-0369 Base Mounted Triple IR Flame Detector NEW 608-0370 Base Mounted Dual UV/IR Flame Detector NEW 608-0371 Base Mounted UV Flame Detector 608-0006 Base with XPERT card 608-0053 Spare blank XPERT card 607-0216 Conduit Box C 615-0276 Manual callpoint surface mount C 615-0277 Manual callpoint surface mount -Isolated C 620-0214 Manual callpoint - weatherproof C 608-0061 20 device isolating base 608-0185 MiniDisc remote indicator C N N N N N N N N N N N N N N APOLLO INTELLIGENT XP95 LOOP INTERFACES AND ACCESSORIES 608-0041 Mini switch monitor C 608-0089 Mini switch monitor with interrupt C 608-0282 Switch monitor with isolator C 608-0260 Switch monitor plus with isolator C 604-0128 Zone monitor with isolator C 608-0303 Output unit with isolator C 608-0193 Input/output unit with isolator C 604-0129 Input/output unit - mains rated output C 608-0305 3-channel input/output unit with isolator C 608-0304 Sounder circuit controller (requires 24Vdc supply) isolated 618-0433 Integrated Base Sounder (55-91dB) 618-0434 Integrated Base Sounder with Isolator (55-91dB) 618-0435 Sounder Beacon Base (55-91dB) 618-0436 Sounder Beacon Base with Isolator (55-91dB) 618-0437 Locking White Cap (for use with 45681-278/277APO) 618-0438 Locking Red Cap (for use with 45681-278/277APO) 618-0232 Ancillary base sounder 619-0100 Loop-powered beacon 619-0161 Loop-powered beacon (clear lens/red flash) 619-0149 Loop-powered beacon (amber) 608-0280 Waterproof Enclosure for Beacon 618-0510 Open Area Sounder Red IP65 618-0511 Open Area Sounder White IP65 618-0512 Open Area Sounder Beacon Red IP65 618-0513 Open Area Sounder Beacon White IP65 618-0514 Open Area Beacon Red IP65 618-0515 Open Area Beacon White IP65 607-0378 Ceiling Tile mounting box for standard bases 607-0390 Ceiling Tile mounting box for sounder bases Public Address Systems C 360 N C = Third Party Certified product ADDRESSABLE FIRE DETECTORS (continued) Code APOLLO XP95 DIN-RAIL INTERFACES N N C NEW 608-0108 Input/Output Unit 608-0372 Mains Input/Output Unit 608-0109 Output Unit N N N N N N C 608-0110 Switch Monitor C 608-0111 Switch Monitor Plus C 604-0131 Zone Monitor (with integral isolator) C 608-0113 Sounder Control Unit C 608-0114 Dual Isolator 608-0373 Mini Switch Module NEW APOLLO XPLORER FIRE DETECTORS N N N N N N N N N N N N N C 607-0267 Optical Smoke Detector C 607-0268 Standard Heat (55ºC) C 608-0216 High Temperature Heat (90ºC) C 608-0217 Spare standard base C 608-0218 LED driver base Optical C 608-0219 LED driver base Standard Heat (55ºC) C 608-0220 LED driver base High Temperature Heat (90ºC) C 608-0221 Base Sounder Optical C 608-0222 Base Sounder Standard Heat (55ºC) C 608-0223 Base Sounder High Temperature Heat (90ºC) C 607-0269 Manual Call Point with Backbox C 608-0224 Output Unit C 608-0225 Isolator Unit APOLLO DISCOVERY INTELLIGENT FIRE DETECTORS Ionisation Smoke Detector C 608-0160 Optical Smoke Detector C 608-0171 Heat Detector C 608-0158 Multisensor Detector C 610-0025 Carbon Monoxide Fire Detector C 615-0278 Red (Surface) with backbox C 615-0279 Red (Surface) with backbox - Isolated C 615-0348 IP67 (Red) with Isolator - resettable C 615-0325 IP67 (Yellow) with Isolator - resettable N N N N N N N N DISCOVERY ACCESSORIES N N N NEW 618-0625 Sounder Beacon Base NEW 618-0626 Open Area Sounder Beacon Red Isolated (Sonos) NEW 618-0627 Open Area Sounder Beacon White Isolated (Sonos) Note 1. Please check with your panel manufacturer for compatibility with these N C = Third Party Certified product 361 Public Address Systems 608-0159 ADDRESSABLE FIRE DETECTORS (continued) Code XPANDER RADIO FIRE DETECTION PRODUCTS Notes 1. Xpander products are only available to companies who have completed training and are certificated to use this product range. 2. A full radio survey is required using the Xpander survey tool prior to installation to ensure suitability of the site and the application. N N N N N N N N N N N N N N NEW 608-0346 Xpander Optical Detector with Address Module NEW 608-0347 Xpander Multisensor Detector with Address Module NEW 608-0348 Xpander A1R Heat Detector with Address Module NEW 608-0349 Xpander CS Heat Detector with Address Module NEW 618-0620 Xpander Sounder (Red) with Sounder Base (Red) NEW 618-0621 Xpander Sounder (White) with Sounder Base (White) NEW 618-0622 Xpander Sounder Beacon (Red) with Sounder Base (Red) NEW 618-0623 Xpander Sounder Beacon (Amber) with Sounder Base (White) NEW 618-0624 Xpander Sounder Beacon (Clear) with Sounder Base (White) NEW 615-0347 Xpander Manual Call Point (Integral Address Module) NEW 608-0350 Xpander Interface Module with Isolator NEW 608-0351 Xpander External Standard Aerial NEW 608-0352 Xpander External Directional Aerial NEW 608-0353 Xpander Survey Tool XPANDER SPARES N N N N N N N N N N N N N N NEW 608-0354 Xpander Optical Detector* NEW 608-0355 Xpander Multisensor Detector* NEW 608-0356 Xpander A1R Heat Detector* NEW 608-0357 Xpander CS Heat Detector* NEW 608-0358 Xpander Address Module NEW 608-0359 Xpander Sounder Base (Red) NEW 608-0360 Xpander Sounder Base (White) NEW 608-0361 XPERT Card (Red) - 7 bit NEW 608-0362 XPERT Card (White) - 7 bit NEW 608-0363 Xpander Sounder (Red) NEW 608-0364 Xpander Sounder (White) NEW 608-0365 Xpander Sounder Beacon (Red) NEW 608-0366 Xpander Sounder Beacon (Amber) NEW 608-0367 Xpander Sounder Beacon (Clear) 362 CAPTION CAPTION CAPTION CAPTION HEADING Code Public Address Systems 363 AUDIO & VISUAL ALARMS Code N N ELECTRONIC SOUNDERS FULLEON ROSHNI LOW PROFILE ELECTRONIC SOUNDERS C 618-0003 RoLP Shallow Base Red - 102dB(A), IP65, 9-28V dc, 16mA C 618-0004 618-0082 618-0567 RoLP Deep Base Red - 102dB(A), IP65, 9-28V dc, 16mA RoLP U Base Red - 102dB(A), IP65, 9-28V dc, 16mA RoLP MAXI Shallow Base Red - 105db(A) (tone 3), IP65, 9-28V dc, 30mA RoLP MAXI Deep Base Red - 105db(A) (tone 3), IP65, 9-28V dc, 30mA RoLP MAXI U Base Red - 105db(A) (tone 3), IP65, 9-28V dc, 30mA 618-0568 618-0569 FULLEON SQUASHNI ELECTRONIC SOUNDERS 618-0570 618-0572 618-0006 N N C 618-0397 C 618-0072 N N C C Squashni G3 AV Platform Sounder Beacon, White with Clear Lens - 90dB(A), 18-28V dc, 10mA Squashni G3 Platform Sounder, White - 90dB(A), 18-28V dc, 4mA Squashni Platform Sounder, White - 93dB(A), 9-28V dc, 18mA (tone 3) Squashni Micro Platform Sounder, Red - 90dB(A) 5.5mA (low setting), 97dB(A) 15mA (high setting), 9-30V dc Squashni Micro Platform Sounder, White - 90dB(A) (low setting), 97dB(A) (high setting), 9-30V dc, 5.5mA (low setting), 15mA (high setting) FULLEON SYMPHONI ELECTRONIC SOUNDERS 618-0067 618-0098 Symphoni Sounder Red - 100dB(A) 12-30V dc, 5mA Symphoni High Output Sounder Red - 114dB(A) (tone 3), 120 dB(A) (tone 6), 9-28V dc, 240mA max FULLEON 2 WIRE SOUNDERS 618-0115 618-0113 618-0112 Symphoni 2 Wire Sounder Red- 100dB(A), 5mA Squashni Micro 2 Wire Red - 86dB(A) 3mA (low output), 95dB(A) 10mA (high output) Squashni Micro 2 Wire White - 86dB(A) 3mA (low output), 95dB(A) 10mA (high output) N FULLEON ASKARI ELECTRONIC SOUNDERS N N NEW C C 618-0619 2 Wire Squashni Sounder Beacon 618-0094 618-0095 618-0386 Askari Compact Sounder Flush Red - 97dB(A), 9-28V dc, 18mA Askari Compact Sounder Flush White - 97dB(A), 9-28V dc, 18mA Askari Panel Sounder Red - 92dB(A) @ 24V dc, 9-28V dc, 18mA @ 24V dc Askari Panel Sounder White - 92dB(A) @ 24V dc, 9-28V dc, 18mA @ 24V dc 618-0328 Ancillary Fire Products N N N N BEACONS FULLEON SOLEX XENON BEACONS C 619-0192 C 619-0193 C 619-0194 C 619-0195 N N Solex 3 Red Lens - Shallow Base, 3-2.5Cd, 10-60V dc, 35mA @ 24V dc Solex 3 Red Lens - Deep Base, 3-2.5Cd, 10-60V dc, 3 5mA @ 24V dc Solex 10 Red Lens - Shallow Base, 10-10Cd, 10-60V dc, 80mA @ 24V dc Solex 10 Red Lens - Deep Base, 10-10Cd, 10-60V dc, 80mA @ 24V dc FULLEON FLASHNI BEACONS C 618-0092 C 618-0171 Flashni Sounder and Beacon Combination - 90dB(A) (tone), Red Lens, Red, Shallow Base, 18-30V dc 68mA (24V version) Flashni Sounder and Beacon Combination - 90dB(A) (tone), Red Lens, Red, Deep Base, 18-30V dc 68mA (24V version) BEACONS SOLISTA LOW CURRENT LED BEACONS 619-0139 619-0134 619-0196 619-0197 619-0138 N C Solista LED Beacon - Conventional Shallow Base, Red, With Base, 10-28V dc, 3mA/6mA (user selectable) Solista LED Beacon - Conventional Shallow Base, White, With Base, 10-28V dc, 3mA/6mA (user selectable) Solista MAXI LED Beacon - Shallow Base, Red, Clear Lens, 9-60V dc, 3mA/6mA/15mA (user selectable) Solista MAXI LED Beacon - Shallow Base, White, Clear Lens, 9-60V dc, 3mA/6mA/15mA (user selectable) Solista Beacon - Squashni Micro Fitting FULLEON SOLISTA LOW CURRENT LED BEACON SOUNDER 618-0396 RoLP Solista LED Beacon Sounder - Red Lens, 102dB(A) (tone 3), 9-28V dc, 21mA (tone 3) FULLEON SYMPHONI ELECTRONIC SOUNDER BEACON 618-0430 618-0431 364 Symphoni AV - Red Body, Red Flash Colour, 18-30V dc, 10mA Max, 100dB(A) Symphoni AV - White Body, Red Flash Colour, 18-30V dc, 10mA Max, 100dB(A) N C = Third Party Certified product FULLEON ASSERTA AUDIO & VISUAL ALARMS (continued) Code FULLEON BELLS 618-0296 Fulleon 6 inch Motorised Bell 24V dc - Centrifugal 617-0070 Fulleon 6 inch Electronic Solenoid Bell 12V dc, Red 617-0044 Fulleon 6 inch Electronic Solenoid Bell 24V dc, Red 617-0043 Fulleon 6 inch Electronic Solenoid Bell 230Vac, Red 617-0042 Fulleon 6 inch Weatherproof Electronic Solenoid Bell 24V dc, Red FULLEON DOOR RETAINERS 620-0504 Wall Mounted Magnetic Door Release 24V dc 620-0528 Wall Mounted Magnetic Door Release 230V ac FULLEON ASSERTA INDUSTRIAL SOUNDERS 618-0391 Asserta Sounder 110dB(A) IP66, Red, 24V 618-0387 Asserta Sounder 110dB(A) IP66, Red, 230V ac 618-0392 Asserta Sounder 120dB(A) IP66, Red, 24V 618-0388 Asserta Sounder 120dB(A) IP66, Red, 230V ac FULLEON ASSERTA INDUSTRIAL SOUNDER BEACONS 618-0382 Asserta Sounder 110dB(A) IP66, Red Body, Red Lens, 24V 618-0390 Asserta Sounder 110dB(A) IP66, Red Body, Red Lens, 230V ac 618-0393 Asserta Sounder 120dB(A) IP66, Red Body, Red Lens, 24V 618-0389 Asserta Sounder 120dB(A) IP66, Red Body, Red Lens, 230V ac FULLEON ASSERTA INDUSTRIAL BEACONS Asserta Beacon, 24V dc, Red Body, Red Lens 619-0154 Asserta Beacon, 230V ac, Red Body, Red Lens FULLEON ASSERTA INDUSTRIAL SOUNDER 618-0426 Asserta Midi Sounder, Red Body, 9-60V dc 618-0427 Asserta Midi Sounder, Red Body, 115/230V ac NEW 618-0607 Asserta Mini Sounder, Red Body, 9-60V dc NEW 618-0608 Asserta Mini Sounder, Red Body, 115/230V ac N N FULLEON ASSERTA INDUSTRIAL SOUNDER BEACONS 618-0428 Asserta Midi Sounder Beacon, Red Body, Red Lens, 9-60V dc 618-0429 Asserta Midi Sounder Beacon, Red Body, Red Lens, 115/230V ac NEW 618-0609 Asserta Mini Sounder Beacon, Red Body, Red Lens, 9-60V dc NEW 618-0610 Asserta Mini Sounder Beacon, Red Body, Red Lens, 115/230V ac NEW 618-0611 Symphoni AV with +, Red Body, Red Flash. NEW 618-0612 Symphoni AV with +, White Body, Red Flash. N N FULLEON VOICE SOUNDERS voice N voice N FULLEON INDUSTRIAL WARNING BEACONS 619-0155 Rotating Mirror Beacon 24V ac/dc, Red 619-0156 Rotating Mirror Beacon 24V ac/dc, Yellow 619-0157 Double Flash Beacon 24V dc, Red 619-0158 Double Flash Beacon 24V dc, Yellow FULLEON INDUSTRIAL WARNING BEACON ACCESSORIES 619-0159 Wall Bracket Accessory for Beacons 619-0160 Guard Accessory for Beacons ACCESSORIES 618-0571 Powered Deep Base, 24V dc, 100mA max. Red 618-0613 Powered Deep Base, 24V dc, 100mA max. White N NEW 365 Domestic Smoke & Carbon Monoxide Detection 619-0153 AUDIO & VISUAL ALARMS 366 (continued) Code CRANFORD CONTROLS VANTAGE SPATIAL 32 TONE SOUNDERS 618-0141 623-0503 618-0140 618-0236 618-0451 N N N N Vantage 24V dc- 32 Tone - Red, Shallow Base Vantage 24V dc- 32 Tone - White, Shallow Base Vantage 24V dc- 32 Tone - Red, Deep Base Vantage 24V dc- 32 Tone - White, Deep Base Vantage 24V dc- 32 Tone - White, Deep Base Anti Tamper VANTAGE SPATIAL SOUNDERS APPROVED C 618-0452 C 618-0453 C 618-0454 C 618-0455 Vantage 24V dc- 32 Tone - Red, Shallow Base EN54 PT3 Approved Vantage 24V dc- 32 Tone - White, Shallow Base EN54 PT3 Approved Vantage 24V dc- 32 Tone - Red, Deep Base EN54 PT3 Approved Vantage 24V dc- 32 Tone - White, Deep Base EN54 PT3 Approved VSO PLATFORM SOUNDERS NN N N VSO PLATFORM SOUNDERS/BEACONS N C NEW 618-0551 VSO 24V dc - 32 Tone - White, EN54 PT 3 Approved NEW 618-0552 Cover Plate - White NEW 618-0553 Cover Plate - Red NEW 618-0602 VSO 24V dc - 32 Tone - LED Base Sounder/Beacon White Body/Clear Lens VECTOR PLATFORM SOUNDERS 618-0123 618-0124 618-0237 620-0337 24V dc 4 Tone - Apollo White 24V dc 4 Tone - Hochiki Ivory Cover Plate - Red Cover Plate - White VARA ROOM SOUNDERS 618-0109 618-0108 618-0111 618-0110 618-0351 24V dc 4 Tone - Red 24V dc 4 Tone - White Vara Sounder with dual LED’s - Red Vara Sounder with dual LED’s - White Vara Sounder with dual LED’s - White c/w ”Fire Alarm’’ text VIPER SPATIAL SOUNDERS 618-0294 618-0246 618-0295 618-0247 618-0456 618-0457 24V dc 4 Tone IP65 - 103 dBa Red 24V dc 4 Tone IP65 - 103 dBa White 24V dc 4 Tone IP65 Hi-output sounder - 107 dBa Red 24V dc 4 Tone IP65 Hi-output sounder - 107 dBa White 110/230V ac 32 Tone Red 110/230V ac 32 Tone White VANTAGE COMBI SOUNDER/BEACONS 618-0150 618-0149 618-0148 618-0147 618-0554 618-0555 618-0556 618-0557 618-0558 618-0494 618-0559 618-0560 618-0561 618-0562 618-0563 618-0564 366 Low Current Combi 24V dc- 32 Tone - Red Body/Red Lens, Shallow Base Low Current Combi 24V dc- 32 Tone - White Body/Red Lens, Shallow Base Low Current Combi 24V dc- 32 Tone - Red Body/Red Lens, Deep Base Low Current Combi 24V dc- 32 Tone - White Body/Red Lens, Deep Base Low Current Combi 24V dc- 32 Tone - Red Body/Amber Lens, Deep Base Low Current Combi 24V dc- 32 Tone - White Body/Amber Lens, Deep Base Low Current Combi 24V dc- 32 Tone - Red Body/Amber Lens, Shallow Base Low Current Combi 24V dc- 32 Tone - White Body/Amber Lens, Shallow Base Low Current Combi 24V dc- 32 Tone - Red Body/Clear Lens, Deep Base Low Current Combi 24V dc- 32 Tone - White Body/Clear Lens Deep Base Low Current Combi 24V dc- 32 Tone - Red Body/Clear Lens, Shallow Base Low Current Combi 24V dc- 32 Tone - White Body/Clear Lens Shallow Base Low Current Combi 24V dc- 32 Tone - Red Body/Blue Lens, Deep Base Low Current Combi 24V dc- 32 Tone - White Body/Blue Lens, Deep Base Low Current Combi 24V dc- 32 Tone - Red Body/Blue Lens, Shallow Base Low Current Combi 24V dc- 32 Tone - White Body/Blue Lens, Shallow Base N C = Third Party Certified product AUDIO & VISUAL ALARMS (continued) Code VANTAGE LED BEACONS 619-0098 24V dc LED beacon - Red Body/Red Lens, Shallow Base 618-0352 24V dc LED beacon - White Body/Red Lens, Shallow Base 619-0099 24V dc LED beacon - Red Body/Red Lens, Deep Base 618-0358 24V dc LED beacon - White Body/Red Lens, Deep Base 619-0186 24V dc LED beacon - Red Body/Amber Lens, Shallow Base 619-0187 24V dc LED beacon - White Body/Amber Lens, Shallow Base 619-0188 24V dc LED beacon - Red Body/Amber Lens, Deep Base 619-0189 24V dc LED beacon - White Body/Amber Lens, Deep Base VOCALARM VOICE ENHANCED SOUNDER 618-0353 24V dc 1 message - Red 618-0354 24V dc 1 message - White 618-0355 24V dc 2 message - Red 618-0356 24V dc 2 message - White VBL BELLS 617-0074 Enhanced 6"’ Fire Alarm Bell - Red 617-0067 VBL 6" Bell 24V dc 95dBa - Grey REMOTE INDICATORS 620-0785 RIU-01 Remote Indicator without text 620-0786 RIU-01B Remote Indicator without text - Deep Back Box 620-0003 RIU-02 Square Indicator c/w ”Fire Detector Operated’’ text 620-0419 RIU-02B Square Indicator as above with Deep Back Box 620-0242 RIU-06 Circular Indicator without text AUXILIARY RELAYS 620-0420 RIU-R24B 24V dc Auxiliary dual relay in single gang housing 620-0421 R24-PCB 24V dc Auxiliiary dual relay PCB only 620-0336 R24-BOX 24V dc Auxiliary dual relay in metal enclosure DOOR RETAINERS 620-0634 DRW-L Low Profile Door Retainer 24V dc c/w Keeper Plate 620-0637 24V dc 500N Low Profile Retainer c/w keeper Plate 620-0635 DRW-M Low Profile Door Retainer 230V dc c/w Keeper Plate 620-0636 FMB-04 Floor Mounting Bracket for Door Retainer 620-0390 KP-02 Universal Keeper Plate 620-0223 DRF-C Chain & Keeper Plate with 1 Metre of chain 620-0530 DRX-200 Floor Mounted Door Retainer 24V dc 200N c/w keeper Plate 620-0705 DRX-500 Floor Mounted Door Retainer 24V dc 500N c/w keeper Plate 620-0706 DRP-L500 24V Door Retainer on a pole - Swivel head 283/350mm 500-750N 620-0707 DRP-L1000 24V Door Retainer on a pole - Swivel head 283/350mm 1000-1300N 620-0708 DRP-S500 24V Door Retainer on a pole - Swivel head 183/250mm 500-750N 620-0709 DRP-S1000 24V Door Retainer on a pole - Swivel head 183/250mm 1000-1300N 620-0788 24V dc Decorative Door Retainer - Chrome 620-0789 24V dc Decorative Door Retainer - Chrome/Switch 620-0790 Chrome Mounting Kit 620-0791 24V dc Decorative Door Retainer - Brass 620-0792 24V dc Decorative Door Retainer - Brass/Switch 620-0793 Brass Mounting Kit NEW 620-0910 IP65 24V dc Door Retainer - 1200N NEW 620-0911 DRW-L-M - Low Profile Metal Door Retainer - 24V dc - 200N NEW 620-0912 DRX-200 VP - Vandal Proof Floor Mounted Door Retainer - 200N NEW 620-0913 DRX-500 VP - Vandal Proof Floor Mounted Door Retainer - 500N C 620-0794 KFDO-CS-EX1.54 Barrier for XP95 I.S. Detectors C 620-0299 KFDO-CS-EX1.51 Barrier for Conventional Detectors C 620-0710 Solenoid Driver C 618-0458 IS-Minialarm - Sounder C 619-0165 IS - Minialite - Beacon - Red Lens C 619-0190 IS - Minialite - Beacon - Amber Lens C 619-0191 IS - Minialite - Beacon - Clear Lens C 618-0459 IS - Minialert - Sounder/Beacon - Red Lens C 618-0565 IS - Minialert - Sounder/Beacon - Amber Lens C 618-0566 IS - Minialert - Sounder/Beacon - Clear Lens C 618-0460 Ex Sounder EX/D 110 dBa 24V dc 32 tone C 619-0166 Ex Xenon Flasher Ex/D 24V dc C 618-0461 Ex Sounder/Xenon Flasher Ex/D 24V dc Combined 620-0520 Enclosure up to 6 Barriers 620-0711 Enclosure for up to 6 Barriers and Translators N N N NHAZARDOUS AREA EQUIPMENT N N N N N N N N N N N N N N C = Third Party Certified product 367 AUDIO & VISUAL ALARMS (continued) Code N N N N KLAXON SONOS ELECTRONIC SOUNDERS C 618-0368 Sonos sounder, 32 tone, red c/w shallow base, 101 dB(A), 18mA, 8-60V dc C 618-0372 Sonos sounder, 32 tone, red c/w deep base, IP65, 101 dB(A), 18mA, 8-60V dc C 618-0367 Sonos sounder, 32 tone, white c/w shallow base, 101 dB(A), 18mA, 8-60V dc C 618-0371 Sonos sounder, 32 tone, white c/w deep base, IP65, 101 dB(A), 18mA, 8-60V dc N N N N N N N N N N KLAXON SONOS SOUNDERS/LED BEACONS C 618-0374 Sonos sounder/led beacon, 32 tone, red c/w shallow base, 101 dB(A), 22mA, 8-60V dc C 618-0376 Sonos sounder/led beacon, 32 tone, red c/w deep base, IP65, 101 dB(A), 22mA, 8-60V dc C 618-0419 Sonos sounder/led beacon, 32 tone, amber lens c/w red shallow base, 101 dB(A), 22mA, 8-60V dc C 618-0530 Sonos sounder/led beacon, 32 tone, amber lens c/w red deep base, IP 65, 101 dB(A), 22mA, 8-60V dc C 618-0531 Sonos sounder/led beacon, 32 tone, clear lens, red leds c/w white shallow base, 101 dB(A), 22mA, 8-60V dc C 618-0532 Sonos sounder/led beacon, 32 tone, clear lens, red leds c/w white deep base, IP 65, 101 dB(A), 22mA, 8-60V dc C 618-0533 Sonos sounder/led beacon, common operation, 32 tone, red c/w shallow base, 101 dB(A), 22mA, 8-60V dc C 618-0534 Sonos sounder/led beacon, common operation, 32 tone, red c/w deep base, IP 65, 101 dB(A), 22mA, 8-60V dc C 618-0535 Sonos sounder/led beacon, common operation, 32 tone, amber lens c/w red shallow base, 101 dB(A), 22mA, 8-60V dc C 618-0536 Sonos sounder/led beacon, common operation, 32 tone, amber lens c/w red deep base, IP 65, 101 dB(A), 22mA, 8-60V dc KLAXON SONOS LED BEACONS 619-0128 Sonos LED beacon, red lens, c/w red shallow base, 5mA, 17-60V dc 619-0130 Sonos LED beacon, red lens, c/w red deep base, 5mA, IP 65, 17-60V dc 619-0182 Sonos LED beacon, amber lens, c/w red shallow base, 5mA, 17-60V dc 619-0183 Sonos LED beacon, amber lens, c/w red deep base, IP 65, 5mA, 17-60V dc Audio & Visual Alarms Clear lens variants available upon request N N KLAXON SONOS BASE SOUNDERS C 618-0424 Sonos universal base sounder, 32 tone, Apollo white, 95 dB(A),7mA, 17-60V dc C 618-0425 Sonos universal base sounder, 32 tone, Hochiki cream, 95 dB(A),7mA, 17-60V dc KLAXON SONOS BASE SOUNDER BEACONS N N NEW 618-0615 Sonos universal base sounder, 32 tone, white, 95 dB(A), 7mA, 17-60V dc, LED beacon NEW 618-0600 Sonos universal base sounder, 32 tone, cream, 95 dB(A), 7mA, 17-60V dc, Led beacon KLAXON SONOS COMPACT SOUNDERS 618-0272 Sonos Compact Sounder, 10 tones, red, 90dB(A), 11mA, 10-30V dc 618-0273 Sonos Compact Sounder, 10 tones, white, 90dB(A), 11mA, 10-30V dc KLAXALARM FIRE ALARM 601-0311 Klaxalarm Terrier battery powered fire alarm callpoint/ sounder unit, 100dB(A) 615-0217 Klaxalarm Boxer battery powered fire alarm callpoint/ sounder unit, 85dB(A) KLAXON MASTER BLASTER HIGH POWER SIREN 618-0153 368 Master Blaster, 127dB(A), 230v AC with 24V dc trigger relay N C = Third Party Certified product AUDIO & VISUAL ALARMS (continued) Code KLAXON NEXUS HIGH-OUPUT ELECTRIC SOUNDER 24V dc 618-0475 Nexus 105 high-output sounder, 64 tones, red, IP 66, 105dB(A), 25mA, 10-60V dc 618-0479 Nexus 110 high-output sounder, 64 tones, red, IP 66, 110dB(A), 43mA, 10-60V dc 618-0483 Nexus 120 high-output sounder, 64 tones, red, IP 66, 120dB(A), 500mA, 10-60V dc KLAXON NEXUS HIGH-OUPUT ELECTRIC SOUNDER 110/230V ac 618-0476 Nexus 105 high-output sounder, 64 tones, red, IP 66, 105dB(A), 40mA, 110/230V ac 618-0480 Nexus 110 high-output sounder, 64 tones, red, IP 66, 110dB(A), 40mA, 110/230V ac 618-0484 Nexus 120 high-output sounder, 64 tones, red, IP 66, 120dB(A), 200mA, 110/230V ac NEXUS HIGH-OUPUT SOUNDER/LED BEACON UNIT 24V dc 618-0537 Nexus 105 high-output sounder/beacon, 64 tones, red led beacon, red sounder, IP 66, 105dB(A), 43mA, 10-60V dc 618-0538 Nexus 105 high-output sounder/beacon, 64 tones, amber led beacon, red sounder, IP 66, 105dB(A), 43mA, 10-60V dc 618-0539 Nexus 110 high-output sounder/beacon, 64 tones, red led beacon, red sounder, IP 66, 110dB(A), 61mA, 10-60V dc 618-0540 Nexus 110 high-output sounder/beacon, 64 tones, amber led beacon,red sounder, IP 66, 110dB(A), 61mA, 10-60V dc 618-0541 Nexus 120 high-output sounder/beacon, 64 tones, red led beacon, red sounder, IP 66, 120dB(A), 518mA, 10-60V dc 618-0542 Nexus 120 high-output sounder/beacon, 64 tones, amber led beacon, red sounder, IP 66, 120dB(A), 518mA, 10-60V dc Clear, Green and Blue lens variants available upon request Clear, Green and Blue lens variants available upon request Clear, Green and Blue lens variants available upon request NEXUS HIGH-OUPUT SOUNDER/5J XENON BEACON UNIT - 24V dc 618-0477 Nexus 105 high-output sounder/beacon, 64 tones, red 5J beacon, red sounder, IP 66, 105dB(A), 275mA ave., 725mA 618-0543 Nexus 105 high-output sounder/beacon, 64 tones, amber 5J beacon, red sounder ,IP 66, 105dB(A), 275mA ave., 725mA peak, 10-60V dc. 618-0481 Nexus 110 high-output sounder/beacon, 64 tones, red 5J beacon, red sounder, IP 66, 110dB(A), 293mA ave., 743mA peak, 10-60V dc. 618-0544 Nexus 110 high-output sounder/beacon, 64 tones, amber 5J beacon, red sounder, IP 66, 110dB(A), 293mA ave., 743mA peak, 10-60V dc. 618-0485 Nexus 120 high-output sounder/beacon, 64 tones, red 5J beacon, red sounder, IP 66, 120dB(A), 750mA ave., 1200mA peak, 10-60V dc 618-0545 Nexus 120 high-output sounder/beacon, 64 tones, amber 5J beacon, red sounder, IP 66, 120dB(A), 750mA ave., 1200mA peak, 10-60V dc. Clear, Green and Blue lens variants available upon request Clear, Green and Blue lens variants available upon request NEXUS HIGH-OUPUT SOUNDER/5J XENON BEACON UNIT - 110/230V ac 618-0478 Nexus 105 high-output sounder/beacon, 64 tones, red 5J beacon, red sounder, IP 66, 105dB(A), 110mA, 110/230V ac 618-0546 Nexus 105 high-output sounder/beacon, 64 tones, amber 5J beacon, red sounder, IP 66, 105dB(A), 110mA, 110/230V ac Clear, Green and Blue lens variants available upon request 618-0482 Nexus 110 high-output sounder/beacon, 64 tones, red 5J beacon, red sounder, IP 66, 110dB(A), 110mA, 110/230V ac 618-0547 Nexus 110 high-output sounder/beacon, 64 tones, amber 5J beacon, red sounder, IP 66, 110dB(A), 110mA, 110/230V ac 618-0486 Nexus 120 high-output sounder/beacon, 64 tones, red 5J beacon, red sounder, IP 66, 120dB(A), 270mA, 110/230V ac 618-0548 Nexus 120 high-output sounder/beacon, 64 tones, amber 5J beacon, red sounder, IP 66, 120dB(A), 270mA, 110/230V ac Clear, Green and Blue lens variants available upon request Clear, Green and Blue lens variants available upon request 369 Audio & Visual Alarms Clear, Green and Blue lens variants available upon request BANSHEE MT AUDIO & VISUAL ALARMS (continued) Code N N N N N N N N N N N N NN NN VIMPEX BANSHEE MT SOUNDERS C 618-0131 Banshee MT RED IP45, 9V dc to 30V dc, 100-112dBA 12mA C 618-0134 Banshee MT RED IP 66, 9V dc to 30V dc, 100-112 dBA 12mA C 618-0206 Banshee MT WHITE IP45, 9V dc to 30V dc, 100-112dBA 12mA C 618-0240 Banshee MT WHITE IP 66, 9V dc to 30V dc,100-112dBA 12mA C 618-0207 Banshee MT GREY IP45, 9V dc to 30V dc, 100-112dBA 12mA C 618-0241 Banshee MT GREY IP 66, 9V dc to 30V dc, 100-112dBA 12mA C 618-0130 Wafer MT Multi-tone sounder, 9V dc to 30V dc, 98dBA 13mA C 618-0228 Cover for wafer C 618-0103 FM Bedroom sounder white 90dBA 24V 7mA C 618-0104 FM Bedroom sounder red 90dBA 24V 7mA C 618-0242 Surface-mount bedroom sounder 96dBA 14mA C 618-0463 True sub 400Hz Animal Friendly Sounder C NEW 618-0604 TriTone Electronic Sounder, Low Current (5mA), Red, Shallow Base EN54 Pt3 C NEW 618-0605 TriTone Electronic Sounder, Low Current (5mA), Red, Deep Base, EN54 Pt3 N N N N N N N VIMPEX MT SOUNDERS C/W DUAL FUNCTION XENON STROBE C 618-0516 FlashTone MT red body/red lens IP45 9-30V dc 52mA@24V C 618-0517 FlashTone MT red body/clear lens IP45 9-30V dc 52mA@24V C 618-0518 FlashTone MT red body/amber lens IP45 9-30V dc 52mA@24V C 618-0519 FlashTone MT red body/blue lens IP45 9-30V dc 52mA@24V C 618-0520 FlashTone MT white body/amber lens IP45 9-30V dc 52mA@24V C 618-0521 FlashTone MT white body/blue lens IP45 9-30V dc 52mA@24V C 618-0522 FlashTone MT white body/green lens IP45 9-30V dc 52mA@24V 618-0173 Deepbase to weatherproof FlashTone MT to IP65 Red 618-0616 Deepbase to weatherproof FlashTone MT to IP65 White N N VIMPEX MT SOUNDERS C/W DUAL FUNCTION LED STROBE C 618-0523 FlashTone MT LED red body/red lens IP45 9-30V dc Typically 17mA@24V C 618-0524 FlashTone MT LED White body/Red lens IP45 9-30V dc Typically 17mA@24V 618-0173 Deepbase to weatherproof FlashTone MT to IP65 Red 618-0616 Deepbase to weatherproof FlashTone MT to IP65 White VIMPEX FLASHDOME MT LED BEACON 619-0181 FlashDomeMT LED Beacon VIMPEX FIRECRYER VOICE SOUNDERS N N N N 618-0122 Single Message Fire Cryer Synchronised 618-0121 Fire-Cryer 4 message sounder 100dBA 20mA 618-0119 Mini Fire-Cryer 4 message sounder 90dBA 20mA 618-0243 Midi Fire-Cryer 4 message sounder 110dBA 618-0244 Maxi Fire-Cryer 4 message sounder 116dBA 618-0432 Ani-Mate, Animal Friendly Voice Sounder 618-0117 Message selection PCB 618-0245 Pre-wired controller VIMPEX BELLS C 617-0005 Kobishi 6" motorised, 95dBA 24V dc 11 mA C 617-0068 Kobishi 6" motorised, 95dBA 12V dc 11 mA C 617-0055 Kobishi 6" motorised, IP65 95dBA 24V dc iSmA C 617-0030 Kobishi 8" motorised, IP65 95dBA 24V dc 15mA 370 N C = Third Party Certified product AUDIO & VISUAL ALARMS (continued) Code VIMPEX STROBELL BELL/STROBE COMBINATION 617-0073 Combined Strobe/Bell unit 24V dc 41mA/61mA VIMPEX STROBES 619-0050 Kobishi SL401 (red) 24V dc 35mA 619-0062 Kobishi SL401 (clear c/w fire legend) 24V dc 35mA 619-0061 Kobishi SL401 (amber) 24V dc 35mA 619-0063 Kobishi SL401 (blue) 24V dc 35mA VIMPEX EASY AV SMART STROBE CONVERSION 618-0423 Easy conversion to strobe/sounder for Roshni 618-0422 Easy conversion to strobe/sounder for LF LP Banshee/Bedlam/Fire-Cryer 618-0509 Universal conversion for sounders bells to AV units VIMPEX SOUNDER/STROBE ACCESSORIES 620-0440 Flush Mounting Ring for BansheeMT or FlashTone 620-0156 Xenon strobe/sounder combination bracket for Banshee/Bedlam or Fire-Cryer® 620-0385 Mains Pack. 230V ac input, 24V dc output (for Banshee) 618-0183 Installation accessory for Deep Base (avoids base thus drilling through retaining IP66) DOOR RETAINERS VIMPEX HEAVY DUTY DOOR RETAINERS N N N C 620-0886 Door retainer wall mount 24V dc, 200N, extra strong housing C 620-0888 Door retainer 230V ac, 200N, extra strong housing C 620-0887 Anti-Vandal Floor Mounting Door Retainer 620-0714 Heavy duty wall mounted door retainer in aluminium casting 400N, 24V dc Also available - Floor mount extension poles and Chrome/Brass Finishes FIRE CALL POINTS N N N C 615-0242 C 615-0241 NEW 615-0337 Resettable Call Point, Flush Mount Resettable Call Point, Surface Mount Also available in Green, Blue, Yellow and White Waterproof Resettable Callpoint, Surface Mount, IP66 REMOTE INDICATORS N N N NEW 620-0924 Vimpex LED Remote Indicator, flush, white NEW 620-0928 Vimpex LED Remote Indicator, surface, white NEW 620-0929 Mounting Box, White HAZARDOUS AREA EQUIPMENT N N N N NEW 619-0211 IS Flash Dome, Intrinsically Safe Beacon, Red, 24VDC, ATEX Approved NEW 620-0922 Enclosure for up to four MTL 5000 Isolators or MTL 7000 Barriers NEW 620-0686 Galvanic Isolator for Banshee IS28 Sounder or IS Flash Dome NEW 620-0923 Zener Barrier for Banshee IS28 Sounder or IS Flash Dome N C = Third Party Certified product 371 24V AOV CONTROL UNITS Code Single Zone Standard Automatic Detection or Fire Panel Control ◆ ◆ ◆ ◆Single Zone Automatic With Keyswitch Override ◆ ◆ ◆ ◆ NEW 620-0946 AOV Single Zone - Auto 1amp 24v NEW 620-0947 AOV Single Zone - Auto 3amp 24v NEW 620-0948 AOV Single Zone - Auto 5amp 24v NEW 620-0949 AOV Single Zone - Auto 10amp 24v NEW 620-0950 AOV Single Zone w/ Keyswitch 1amp 24v NEW 620-0951 AOV Single Zone w/ Keyswitch 3amp 24v NEW 620-0952 AOV Single Zone w/ Keyswitch 5amp 24v NEW 620-0953 AOV Single Zone w/ Keyswitch 10amp 24v Single Zone Automatic With Comfort Control/ Fireman Control ◆ ◆ ◆ ◆ NEW 620-0954 AOV Single Zone w/ Comfort Control 1amp 24v NEW 620-0917 AOV Single Zone w/ Comfort Control 3amp 24v NEW 620-0918 AOV Single Zone w/ Comfort Control 5amp 24v NEW 620-0955 AOV Single Zone w/ Comfort Control 10amp 24v 1-15 Zone Automatic With Detection or Fire Panel Control ◆ ◆ ◆ ◆ ◆ ◆ Actuators ◆ ◆ ◆ ◆ Mounting Brackets ◆ ◆ ◆ ◆ ◆ ◆ ◆ Call Points ◆ ◆ ◆ ◆ Detectors & Sensors ◆ ◆ ◆ NEW 620-0956 AOV Multi 5 zone - Auto 5amp 24v NEW 620-0957 AOV Multi 5 zone - Auto 10amp 24v NEW 620-0958 AOV Multi 10 zone - Auto 10amp 24v NEW 620-0959 AOV Multi 10 zone - Auto 20amp 24v NEW 620-0960 AOV Multi 15 zone - Auto 15amp 24v NEW 620-0961 AOV Multi 15 zone - Auto 30amp 24v NEW 620-0919 Chain Actuator 24V/2.1A 300N Stroke 100 - 400mm - White NEW 620-0962 Chain Actuator 24V/2.1A 300N Stroke 100 - 400mm Matt black NEW 620-0963 Chain Actuator 24V/2.1A 300N Stroke 100 - 400mm - Silver NEW 620-0920 Chain Actuator 24V/2.1A 400N Stroke 800mm - White NEW 620-0964 Standard bracket set for ACT-301 NEW 620-0965 Fall back bracket set for ACT-301 NEW 620-0966 Small Swivel Bracket for ACT-301 NEW 620-0945 Large Swivel Bracket for ACT-301 NEW 620-0967 Slide Bracket for ACT-501 NEW 620-0968 Pivot bracket for ACT-501 NEW 620-0969 Z Bracket for Act-501 NEW 620-0970 Manual Call Point standard yellow NEW 620-0921 Manual Control Unit yellow with clear cover open/close switches NEW 620-0971 Keyswitch Call Point yellow - open/close NEW 620-0972 Keyswitch Call Point yellow - auto/open/close NEW 620-0973 Photoelectric smoke detector (needs DET-009) NEW 620-0974 Mounting base - auto reset NEW 620-0975 Rain sensor - auto reset 372 24V DC POWER SUPPLY UNITS Code CUSTOM ELECTRONICS Charger/Power Supply units - Boxed 24V Standard 621-0002 1 Amp @ 24V dc Power Supply C/W Fault Relay 621-0004 3 Amp @ 24V dc Power Supply C/W Fault Relay 621-0006 5 Amp @ 24V dc Power Supply C/W Fault Relay 621-0094 10 Amp @ 24V dc Power Supply C/W Fault Relay Charger/Power Supply units - Boxed 24V Standard with DIN rails 621-0046 1 Amp @ 24V dc PSU C/W Fault Relay + one DIN rail (Enc 400 x 400 x 135) 621-0047 3 Amp @ 24V dc PSU C/W Fault Relay + one DIN rail (Enc 400 x 400 x 135) 621-0095 5 Amp @ 24V dc PSU C/W Fault Relay + one DIN rail (Enc 400 x 400 x 135) Sounder Circuit Booster & SLA Charger Boxed 24V Standard 621-0108 Sounder Booster 1 Amp @ 24V dc C/W Relay 621-0109 Sounder Booster 3 Amp @ 24V dc C/W Relay 621-0110 Sounder Booster 5 Amp @ 24V dc C/W Relay Charger/Power Supply Units - Boxed 24V EN54-4 compliant 621-0176 EN54 4/1 - 4A load and 1A charger 621-0177 EN54 3/2 - 3A load and 2A charger 621-0178 EN54 3/1 - 3A load and 1A charger 621-0205 EN54 1/2 - 1A load and 2A charger ◆ NEW Economy Charger Power Supply Units - Boxed 24V No monitoring ◆ ◆ ◆ NEW 621-0202 1 Amp @ 24V.d.c Charger PSU NEW 621-0203 3 Amp @ 24V.d.c Charger PSU NEW 621-0204 5 Amp @ 24V.d.c Charger PSU Trans/Rec Power Supply units - Boxed 24V No battery charger 620-0235 Transformer Rectifier 1 Amp @ 24V dc 621-0098 Transformer Rectifier 1 Amp @ 24V dc C/W Relay and Fault Relay 620-0237 Transformer Rectifier 3 Amp @ 24V dc 621-0102 Transformer Rectifier 3 Amp @ 24V dc C/W Relay and Fault Relay 620-0239 Transformer Rectifier 5 Amp @ 24V dc 621-0106 Transformer Rectifier 5 Amp @ 24V dc C/W Relay and Fault Relay Enclosures 621-0115 Battery Cabinet (2x12V 7AHr) 320mm x 235mm x 80mm 621-0116 Battery Cabinet (2x12V 18AHr) 400mm x 400mm x 110mm 621-0117 Battery Cabinet (2x12V 24AHr) 400mm x 400mm x 200mm 621-0045 DIN rail enclosure with 2 DIN rails 400mm x 400mm x 135mm Auxiliary Relay Devices 621-0118 24 Volt 5 Amp dc Resistive Load (PCB only) 621-0119 24 Volt 5 Amp dc Resistive Load in IP65 ABS enclosure 621-0120 24 Volt 5 Amp dc Relay on Single Gang Plate Remote Indicators - Dual voltage 24V & 2.5V Red LED 621-0121 Remote Indicator with “Fire Alarm Detector Operated” Text - 5mm 620-0783 Remote LED Indicator/ Buzzer Unit 620-0784 Remote LED Indicator/ Buzzer Unit C/W Keyswitch 373 24V DC POWER SUPPLY UNITS (continued) Code EN54-4 POWER SUPPLIES ELMDENE N N N N N C C C C C ELMDENE EN54 - 4 621-0149 24v 1amp PSU 420h x 400w x 80d Vds certificated to EN54-4 621-0147 24v 2amp PSU 420h x 400w x 80d Vds certificated to EN54-4 621-0148 24v 3amp PSU 420h x 400w x 80d Vds certificated to EN54-4 621-0023 24v 5amp PSU 420h x 400w x 80d Vds certificated to EN54-4 621-0146 24v 5amp PSU 2.5A to load and 2.5A battery charging. 420h x 400w x 80d Vds certificated to EN54-4 ELMDENE Transformer/Rectifier 620-0243 24v 2amp switched output PSU for Fire 200h x 230w x 80d 621-0065 24v 4amp switched output PSU for Fire 200h x 230w x 80d ELMDENE Beacons 619-0003 24v -2 watt beacon in Red with Surface mount assembly 619-0001 24v -2 watt beacon in Amber with Surface mount assembly 619-0060 240v -2 watt beacon in Red with Surface mount assembly ELMDENE 24v Battery Monitored 621-0028 24v 1amp PSU 330w x 275h x 80d Battery Monitored 621-0027 24v 2amp PSU 330w x 275h x 80d Battery Monitored 621-0026 24v 3amp PSU 330w x 275h x 80d Battery Monitored 621-0024 24v 5amp PSU 330w x 275h x 80d Battery Monitored ELMDENE 24v Standard 374 621-0080 24v 1Amp PSU 330w x 275h x 80d Standard 621-0081 24v 2Amp PSU 330w x 275h x 80d Standard 621-0082 24v 3Amp PSU 330w x 275h x 80d Standard 621-0083 24v 5Amp PSU 330w x 275h x 80d Standard N C = Third Party Certified product ANCILLARY FIRE PRODUCTS Code STOPPER - Available in RED as standard. Other colours available upon request 601-0432 STI6530 Stopper flush mounted 601-0431 STI6531 Stopper surface mounted 601-0430 STI6532 Stopper flush mounted with integral sounder 601-0429 STI6533 Stopper surface mounted with integral sounder OPTIONS 620-0936 /BS Security break seal 620-0937 CL Special custom label 620-0938 DC1224 Allows connection to 12 or 24 VDC supply ACCESSORIES 620-0939 STI6501Weather gasket set 601-0428 STI650330 mm acrylic spacer (included with 6531 & 6533) 601-0427 STI6504 50 mm acrylic spacer 601-0555 STI/BS Breakable seals (packs of 10) CALL POINT STOPPER – Available in RED as standard. Other colours available upon request 620-0899 STI6930 New Call Point Stopper flush mounted 620-0858 STI6931 New Call Point Stopper surface mounted EXIT STOPPER – Available in RED as Standard. Also available in green, upon request 601-0425 STI6400 Emergency Exit Alarm 601-0424 STI6402 As above for double doors ACCESSORIES 620-0940 CO23/A Spare keys (only one supplied) 601-0423 STI6400/RK Remote installation Kit 601-0422 STI6400/RS Remote 98 dB sounder 601-0599 STIL6400 Alarm Warning Emergency Exit Sign 127mm h x 127 mm w EXTINGUISHER STOPPER – Available in RED as standard 601-0412 STI6200 Fire Extinguisher theft Stopper 620-0941 STI6200/DC1224 As above but suitable for connection to 12 or 24 VDC ACCESSORIES 620-0559 STI6204 Service/deactivation cable 601-0411 STI6205 Operating cable kit (includes cable & seal device) 620-0560 STI6206 Operating cable seal 620-0561 F021 Tamper Key 620-0938 DC1224 Allows connection of 12 or 24 VDC supply STEEL WEB STOPPERS – To protect smoke detectors and fire bells 601-0420 STI9604 Low profile 75 d x 175 diameter - flush mount 601-0419 STI9604-SS Low profile 75 d x 175 diameter - flush mount stainless steel finish 601-0418 STI9606 Low profile 95 d x 175 diameter - flush mount 601-0417 STI9609 High profile 124 d x 215 diameter - flush mount 601-0416 STI-9609-SS High profile 124 d x 215 diameter - flush mount stainless steel finish 601-0421 STI9601 Low profile 70 d x 210 diameter - flush mount 620-0942 STI9713 Low profile 63 d x 174 diameter - flush mount photoelectric detectors 601-0410 STI9605 Low profile 115 d x 180 diameter - surface mount 601-0414 STI9605-SS Low profile 115 d x 180 diameter - surface mount stainless steel finish 601-0413 STI9610 High profile 145 d x 214 diameter - surface mount 601-0415 STI9602 Low profile 108 d x 215 diameter - surface mount 620-0943 STI9712 174 d x 115 diameter - surface mount photoelectric detectors Fire Call points. Other colours available upon request 615-0338 RP-RF-01 ReSet Call Point EN54-11, Flush Mount 615-0339 RP-RS-01 ReSet Call Point EN54-11, Surface Mount 615-0340 WRP-R-01 IP67 Waterproof ReSet Call Point 375 RED REEL STANDARD FIRE RESISTANT CABLE Code N N N N N N N N N VENTCROFT STANDARD FIRE PERFORMANCE CABLE LPCB APPROVED C 611-0234 2 Cores & Earth 1.00mm (Red) C 611-0232 2 Cores & Earth 1.50mm (Red) C 611-0236 2 Cores & Earth 2.5mm (Red) C 611-0231 2 Cores & Earth 1.50mm (Red) 500 Mtrs Reel C 611-0238 3 Cores & Earth 1.50mm (Red) C 611-0243 4 Cores & Earth 1.00mm (Red) C 611-0241 4 Cores & Earth 1.50mm (Red) C 611-0240 4 Cores & Earth 1.50mm (Red) 500 Mtrs Reel C 611-0245 4 Cores & Earth 2.5mm (Red) WHITE REEL N N N N N N C 611-0235 2 Cores & Earth 1.00mm (White) C 611-0233 2 Cores & Earth 1.50mm (White) C 611-0237 2 Cores & Earth 2.5mm (White) C 611-0239 3 Cores & Earth 1.50mm (White) C 611-0244 4 Cores & Earth 1.00mm (White) C 611-0242 4 Cores & Earth 1.50mm (White) BLACK REEL N C 611-0230 2 Cores & Earth 1.50mm (Black) N C 376 = Third Party Certified product ENHANCED FIRE RESISTANT CABLE Code VENTCROFT ENHANCED FIRE PERFORMANCE CABLE LPCB APPROVED Pending 611-0266 2 Cores & Earth 1.50mm (Red) Pending 611-0267 4 Cores & Earth 1.50mm (Red) Pending = Third Party Certification pending 377 First Fix & Fire Cable Ancillaries FIRST FIX & FIRE CABLE ANCILLARIES Code Code Clips - Glands - Shrouds and Locknuts Girder Clips 611-0188 AC8 P Clips White (100) for 2 core 1.00mm & 1.50mm 611-0205 Girder Clips 7-9mm Cable Run Clip Large (100) 611-0187 AC8 P Clips Red (100) for 2 core 1.00mm & 1.50mm 611-0206 Girder Clips 10-11mm Cable Run Clip Large (100) 611-0189 AC9 P Clips Red (100) for 4 core 1.00mm 611-0207 Girder Clips 12-14mm Cable Run Clip Large (100) 611-0190 AC9 P Clips White (100) for 4 core 1.00mm Accessory Boxes 611-0191 AC11 P Clips Red (100) for 2 core 2.50mm / 4 core 1.50mm 611-0192 AC11 P Clips White (100) for 2 core 2.50mm / 4 core 1.50mm 611-0193 302 RSFJ Double Clips Red (50) for 2 core 1.00mm 611-0194 302 RSFJ Double Clips White (50) for 2 core 1.00mm 611-0195 342 RSFJ Double Clips Red (50) for 2 core 1.50mm 611-0196 342 RSFJ Double Clips White (50) for 2 core 1.50mm 611-0197 422 RSFJ Double Clips Red (50) for 4 core 1.50mm 611-0198 422 RSFJ Double Clips White (50) for 4 core 1.50mm 611-0199 251 20mm Gland Red (100) requires locknut 611-0213 Coupler for 25 x 16 Trunking (Red) 611-0200 251 20mm Gland White (100) requires locknut 611-0214 End cap for 25 x 16 Trunking (Red) 611-0209 20mm Locknut White (100) 611-0215 Equal tee for 25 x 16 Trunking (Red) 611-0208 20mm Locknut Red (100) 611-0216 Internal bend for 25 x 16 Trunking (Red) 611-0201 LSOH Shrouds Red (10) 611-0217 External bend for 25 x 16 Trunking (Red) 611-0202 LSOH Shrouds White (10) 611-0246 Flat bend for 25 x 16 Trunking (Red) 620-0175 Plastic Trunking 25 x 16 x 3m (Red) Cable Stripper 611-0158 Firecel Cable Stripper Stainless Steel Cable Ties 611-0203 Stainless Steel Cable Ties 225mm x 6.0mm (100) 611-0204 Stainless Steel Cable Ties 450mm x 6.0mm (100) 611-0250 MK Red Alert Backbox c/w Flanged Entry (Red) 611-0254 MK White Alert Backbox c/w Flanged Entry (White) 611-0251 MK Red Alert White Circular Box 611-0210 Single gang / Single entry accessory box (Red) 611-0211 Single gang / Double entry accessory box (Red) 611-0212 Circular accessory box 1 or 2 entry (Red) Trunking & Trunking Fittings Metal Conduit Boxes 611-0220 1 x 20mm metal conduit box (Stop end box) 611-0221 2 x 20mm metal conduit box (U box) 611-0248 2 x 20mm metal conduit box (Thru box) 378 EMERGENCY LIGHTING Code SPEL EMERGENCY LIGHTING 622-0469 Dalby 8W Non-Maintained Bulkhead 622-0470 Dalby 8W Maintained Bulkhead 622-0479 Dalby 8W Non-Maintained Exit Sign 622-0480 Dalby 8W Maintained Bulkhead Exit Sign 622-0471 White Semi-Recessing Kit to suit Dalby 622-0472 Arrow Down Legend to Suit Dalby 622-0473 Arrow Left Legend to Suit Dalby 622-0474 Arrow Right Legend to Suit Dalby 622-0475 Arrow Up Legend to Suit Dalby 622-0355 Spelex 8W Maintained IP65 Exit Sign 622-0354 Spelex 8W Non-Maintained IP65 Exit Sign 622-0476 White Semi-Recessing Kit to suit Spelex 622-0356 Arrow Down Legend to Suit Spelex 622-0357 Arrow Left Legend to Suit Spelex 622-0358 Arrow Right Legend to Suit Spelex 622-0359 Arrow Up Legend to Suit Spelex 622-0434 Petina 3 x 1W LED NM3/M3 White Exit Sign 622-0435 Petina 3 x 1W LED NM3/M3 Black Exit Sign 622-0436 Petina 3 x 1W LED NM3/M3 Silver Grey Exit Sign 622-0443 Arrow Down Legend to Suit Petina 622-0444 Arrow Left Legend to Suit Petina 622-0445 Arrow Right Legend to Suit Petina 622-0446 Arrow Up Legend to Suit Petina 622-0477 50W 12V Non-Maintained Lighting Train 622-0478 50W 12V Maintained Lighting Train 622-0349 Pictor 8W Maintained Polycarbonate Exit Sign 622-0348 Pictor 8W Non-Maintained Polycarbonate Exit Sign 622-0350 Arrow Down Legend to Suit Herald/Pictor 622-0351 Arrow Left Legend to Suit Herald/Pictor 622-0352 Arrow Right Legend to Suit Herald/Pictor 622-0353 Arrow Up Legend to Suit Herald/Pictor ORDERING EMERGENCY LIGHTING When ordering lighting products the following should be confirmed: • • • • Type required (i.e. luminaire, bulkhead, exit sign) Colour finish required Mode required (i.e. mains, non-maintained, maintained) If applicable, legend type required (see guide below) 379 ORDERING EMERGENCY LIGHTING When ordering lighting products the following should be confirmed: • • • • Type required (i.e. luminaire, bulkhead, exit sign) Colour finish required Mode required (i.e. mains, non-maintained, maintained) If applicable, legend type required (see guide below) EMERGENCY LIGHTING (continued) Code 622-0302 Anglolite 8W White Non-Maintained Recessed Luminaire 622-0303 Anglolite 8W Brass Non-Maintained Recessed Luminaire 622-0304 Anglolite 8W Chrome Non-Maintained Recessed Luminaire 622-0305 Anglolite 8W White Maintained Recessed Luminaire 622-0306 Anglolite 8W Brass Maintained Recessed Luminaire 622-0307 Anglolite 8W Chrome Maintained Recessed Luminaire 622-0308 Mini-D 16W Mains IP65 Circular Luminaire 622-0309 Mini-D 28W Mains IP65 Circular Luminaire 622-0310 Mini-D 16W Maintained IP65 Circular Luminaire 622-0311 Mini-D 28W Maintained IP65 Circular Luminaire 622-0468 White Semi-Recessing Kit to suit Mini-D 622-0347 Herald 8W Maintained Exit Box 622-0346 Herald 8W Non-Maintained Exit Box 622-0350 Arrow Down Legend to Suit Herald/Pictor 622-0351 Arrow Left Legend to Suit Herald/Pictor 622-0352 Arrow Right Legend to Suit Herald/Pictor 622-0353 Arrow Up Legend to Suit Herald/Pictor 622-0280 Phantom 2 x 21W NM3 Tungsten Twin-Spot 622-0257 Phantom 2 x 20W NM3 Tungsten Halogen Twin-Spot 622-0256 Phantom 2 x 55W NM1 Tungsten Halogen Twin-Spot 622-0440 Rota 3 x 1W High Output LED M3 White Exit Sign 622-0441 Rota 3 x 1W High Output LED M3 Black Exit Sign 622-0442 Rota 3 x 1W High Output LED M3 Silver Grey Exit Sign 622-0447 Arrow Down Legend to Suit Rota 622-0448 Arrow Left Legend to Suit Rota 622-0449 Arrow Right Legend to Suit Rota 622-0450 Arrow Up Legend to Suit Rota SPEL CENTRAL SYSTEMS To compliment our extensive range of emergency lighting, SPEL also supply central battery and static inverter systems, covering various Voltages and battery types and are manufactured to the highest standards to provide long, trouble-free service. The central location of the cubicles ensures that maintenance, control and monitoring of the emergency lighting system is far easier than conventional emergency lighting. For further technical information on SPEL central systems, please contact our technical department. 380 ORDERING EMERGENCY LIGHTING When ordering lighting products the following should be confirmed: • Type required (i.e. luminaire, bulkhead, exit sign) • Colour finish required • Mode required (i.e. mains, non-maintained, maintained) • If applicable, legend type required (see guide below) EMERGENCY LIGHTING (continued) Code 622-0337 Eden 8W Non-Maintained Bulkhead 622-0338 Eden 8W Maintained Bulkhead 622-0467 White Semi-Recessing Kit to suit Eden 622-0229 Self-Adhesive Legend Kit 622-0361 Talisman 8W Maintained Brass Exit Sign 622-0360 Talisman 8W Non-Maintained Brass Exit Sign 622-0363 Regal 8W Maintained Brass Recessed Exit Sign 622-0362 Regal 8W Non-Maintained Brass Recessed Exit Sign 622-0364 Arrow Down Legend to Suit Talisman/Regal 622-0365 Arrow Left Legend to Suit Talisman/Regal 622-0366 Arrow Right Legend to Suit Talisman/Regal 622-0367 Arrow Up Legend to Suit Talisman/Regal 622-0312 Capella 16W White Mains Circular Luminaire 622-0313 Capella 28W White Mains Circular Luminaire 622-0314 Capella 16W White Maintained Circular Luminaire 622-0315 Capella 28W White Maintained Circular Luminaire Lighting Design Guidance The following information outlines some basic design requirements of BS5266 and prEN 1838 (draft European Standard) and is intended for guidance only, your emergency lighting stystem design should be approved by your local fire authority and/or the Building Control Department prior to installation. Emergency lighting lighting should Emergency shouldbe beprovided provided- -atchanges changesin inDirection Direction - at and Corridor intersections and Corridor Intersections --at at Fire Fire Alarm Fire and Alarm Callpoints Callpoints Fire and FirstAid Aid Equipment Equipment and and Potential Potential Hazards Hazards First 2 , Lift cars and Plant Rooms - inToilets Toiletsexceeding exceeding8m 8m - in , Lift cars and Plant Rooms 2 - outside outside each each Final Final Exit at changes in floor level - at- changes in floor level and and Flights of Stairs Flights of Stairs With Withilluminated iluminatedExit ExitSigns SignsatatExit ExitDoors Doors 381 EMERGENCY LIGHTING (continued) Code EMERGI-LITE When ordering lighting products the following should be confirmed: • • • • Type required (i.e. luminaire, bulkhead, exit sign) Colour finish required Mode required (i.e mains, non-maintained, maintained) If applicable, legend type required (see guide below) 622-0511 Safety Self Contained Safety 8WT5 NM3 White 622-0512 Safety Self Contained Safety 8WT5 M3 White 622-0513 Navigator Compact Self Contained Exit Sign 8WT5 NM3 White 622-0514 Navigator Compact Self Contained Exit Sign 8WT5 M3 White 622-0515 Navigator Compact Legend Screen Printed Panel Pictogram Arrow Down 622-0516 Navigator Compact Legend Screen Printed Panel Pictogram Arrow Left 622-0517 Silver-Lite Self Contained Recessed 8WT5 NM3 622-0518 Silver-Lite Self Contained Recessed 8WT5 M3 622-0519 Silver-Lite Signs Legend Screen Printed Panel Pictogram 622-0520 Silver-Lite Signs Accessory Trim Kit Exit Sign White 622-0521 Silver-Lite Signs Accessory Trim Kit Exit Sign Brass 622-0522 Silver-Lite Signs Accessory Trim Kit Exit Sign Stainless Steel 622-0523 Silver-Lite Accessory Trim Kit Recessed White 622-0524 Silver-Lite Accessory Trim Kit Recessed Brass 622-0525 Silver-Lite Accessory Trim Kit Recessed Stainless Steel 382 EMERGENCY LIGHTING (continued) Code 622-0526 Range-Lite Self Contained Twin Spot 2X18W HIT NM3 White 622-0527 Range-Lite Self Contained Twin Spot 2X20W HAL NM3 White 622-0528 Range-Lite Self Contained Twin Spot 2X55W HAL NM1 White 622-0529 Low Voltage Torpedo Self Contained Power Pack 12V50W NM3 622-0530 Low Voltage Self Contained Power Pack 12V50W M3 622-0507 LED Downlighter Self Test 622-0508 LED Downlighter Self Test 622-0509 AC/DC LED Downlighter 622-0510 AC/DC LED Downlighter 383 VOICE ALARM SYSTEMS Code SIGNET LinX SINGLE ZONE VOICE ALARM SYSTEM • Includes many of the features of larger voice alarm systems, but in a compact wall-mount swing frame rack • Easy to install - supplied pre-wired and ready for connection to the fire alarm, loudspeakers and batteries • Comes with a wall mounting fire microphone in a lockable red enclosure • Three spare inputs - two for paging mics. and one spare input for a music source • Available in 400W multiples Linx Mainframe and peripherals 620-0806 LINX1-400 1 Zone 400 Watt VA system 620-0807 LINX1-800 1 Zone 800 Watt VA system 620-0808 iXLS 6:1 Prioritised LS mixer 620-0809 ALFI2 2 Input fire alarm interface with reset 620-0810 TIJLS 22kHz Crystal controlled tone injector 0 to 50V Microphones and paging consoles 620-0811 1ZDM 1 Zone LS local desk paging microphone 620-0812 FM1 1 Zone Fireman’s microphone with red case Message storage 620-0813 SVMP2-8 Sound Vault dual 30 second LS message player 620-0814 Sndvaultexe Sound Vault upload/ download software & lead SIGNET INTEGRITY 2-64 ZONE VOICE ALARM SYSTEM A fully integrated VA, PA and BGM solution for theatres, hotels, sports grounds, exhibition halls, shopping centres, etc. • Unique PC software allows the system to be designed and demonstrated prior to purchase, giving customers and designers confidence and control over the site’s voice evacuation strategies • Simple monitored interface with fire systems via normal sounder circuits • Ideal for applications requiring complex routing of multiple channels, such as alert, evacuate, bomb and test messages, paging and music • Large 40 character panel displays date/time, location and engineer configurable fault texts Integrity mainframe and configuration software 620-0815 MF16 Integrity 16 zone mainframe, main CPU, 24VDC, fault display & configuration software 620-0816 CFG Integrity configuration software Input/output modules 620-0817 1LS All-call Fire mic card, two message trigger, max four mics 620-0818 SVMA 30 second LS message card, c/w alert message 620-0819 SVME 30 second LS message card, c/w evac message 620-0820 SVM-CUST 30 second LS message card, c/w custom message 620-0821 CI-16 16 input, one reset, one output contact card 620-0822 BGM Stereo music input card, four externally selectable groups 620-0823 OP2 2 zone audio output card 620-0824 GPI General purpose interface card 620-0825 INTHUB Microphone interface for Integrity card Microphones & paging consoles 620-0826 FMIC Firefighter’s all call mic, 2 message trigger 620-0927 FMX Fire mic. adaptor board 620-0827 1ZDM 1 Zone LS local desk paging microphone 620-0828 MPC16I 16 button desk mount emergency paging panel c/w fault display & Integrity firmware 620-0829 MPC16WI 16 button wall mount emergency paging panel c/w fault display & Integrity firmware 620-0830 MPP24/WI 24 button wall mount emergency paging panel c/w fault display, 32 input opto isolated fire alarm interface & Integrity firmware 620-0831 MPC32I 32 button desk mount emergency paging panel c/w fault display & Integrity firmware 620-0832 MPC32WI 32 button wall/rack mount emergency paging panel c/w fault display & Integrity firmware 620-0833 MPC48I 48 button desk mount emergency paging panel c/w fault display & Integrity firmware 620-0834 MPC64I 64 button desk mount emergency paging panel c/w fault display & Integrity firmware SIGNET LS DISTRIBUTED VOICE ALARM SYSTEM (prices on application) • Ideal for applications requiring complex audio routing such as airports, shopping centres and stadia • A 240 audio zone capacity 8 channel matrix with multiple links to distributed fire detection systems and optional PC controlled functions for paging and automated messaging • Allows PA, VA & BGM to be integrated in one system • Dual data rings ensure continuous operation of system and transmission of data even in the event of catastrophic failure Prices for racks, rack building, loudspeakers, background music sources and commissioning available on request 384 VOICE ALARM SYSTEMS (continued) Code C-TEC AVAC VOICE ALARM SYSTEM • A low-cost, high quality modular voice alarm system purposely designed to simplify the provision of a fully BS5839-8 compliant voice alarm system. • Comprises conventional and analogue (Apollo XP95/Discovery) fire alarm interfaces • A high-quality digital message store containing programmable Evacuate, Alert and Test messages • A prioritised mixer • Two x 60-Watt max. peak Class D amplifiers (plus an optional standby amp) • An EN54-4 compliant switch mode power supply and battery charger • Three balanced line level inputs for the (optional) connection of a fire mic, paging/public address equipment and a background music source MASTER AMPLIFIERS 620-0428 620-0429 VA403 Master AVAC dual 60W amplifier, charger & PSU. Includes fire alarm interface, emergency mic., paging and BGM connections VA403H Master AVAC dual 60W amplifier, charger & PSU c/w ‘hotswap’ standby amp. Includes fire alarm interface, emergency mic., paging and BGM connections SLAVE AMPLIFIERS 620-0426 VA402 Slave AVAC dual 60W amplifier, charger & PSU. Includes local paging and BGM connections Includes fire alarm interface, emergency mic., paging and BGM connections 620-0427 VA402H Slave AVAC dual 60W amplifier, charger & PSU c/w ‘hotswap’ standby amp. Includes local paging and BGM connections MICROPHONES VA405 Emergency microphone (max. 1 per system) 620-0586 VA406 Line level paging microphone (max. 1 per system) SPEAKERS 620-0697 VA421A 6" 6W ceiling speaker c/w steel fire dome & ceramic terminal block 620-0698 VA422A 8W wall mounting metal cabinet speaker c/w ceramic terminal block 620-0434 VA423 8W wall mounting bi-directional metal speaker c/w ceramic terminal block 620-0699 VA428 30W pendant loudspeaker c/w 8m cable and internal stress wire (requires VA490 or VA492) 620-0588 VA430 6W round wall/ceiling speaker in metal cabinet c/w ceramic terminal block 620-0700 VA490 Ceramic terminal block and thermal fuse assembly (use to convert wire-end sealer to BS5839-8, needs adaptable back box) 620-0701 VA492 VA loudspeaker metal termination box c/w 2 x ceramic terminal blocks and thermal fuses Speakers for special applications-column, horn, sound projection, spherical suspension, etc. are also available (special order only) AVAC TESTING EQUIPMENT 620-0585 LOADMASTER Loudspeaker line tester 623-0485 PNGN Pink noise generator 385 Voice Alarm Systems 620-0430 NURSECALL/DISABLED TOILET ALARM SYSTEMS Code EMERGENCY CALL POINTS Can generate standard and emergency calls 623-0280 NC802DEB-1/2 Emergency call point, button reset c/w remote socket 623-0279 NC802DEM Emergency call point, magnetic reset, with remote socket IP65 WATER RESISTANT ALERT POINTS Can be set up to generate standard or emergency calls (not both) 623-0363 NC802DEWM Water resistant master alert point, magnetic reset, no remote socket 623-0362 NC802DEWS Water resistant slave alert point, no on-board reset, no remote socket, max 10 per master 623-0692 NC802DESS IP69K sauna alert point (must be used as a slave to a NC802DEWM) STAINLESS STEEL ALERT CALL POINTS Can be set up to generate standard or emergency calls (not both) 623-0385 NC802DEM/SS Stainless steel call point, magnetic reset, no remote socket INFRARED CALL POINTS AND CEILING RECEIVERS Generate standard and/or emergency calls when triggered by a suitable transmitter 623-0210 NC802DERB Infrared call point, button reset c/w remote socket 623-0209 NC802DERM Infrared call point, magnetic reset c/w remote socket 623-0214 NC302RXC Infrared master ceiling receiver, no on-board reset 623-0215 NC302RXCS Infrared slave ceiling receiver, max. 3 per master INFRARED TRANSMITTERS For triggering Infrared call points and ceiling receivers 623-0623 QT412RXA Mk2 transmitter, push/pull for emergency 623-0618 QT412RXCA Mk2 transmitter, push for call/pull for emergency 623-0621 QT424/1 Single way charging unit for NC412 range transmitter 623-0617 QT424/10 Ten way charging unit for NC412 range transmitters RESET POINTS Can be used to reset devices which do not have an on-board reset facility 623-0015 NC809DB Button reset point 623-0283 NC809DM Magnetic reset point 623-0216 NC899IRR Keyswitch reset point, for use with infra-red ceiling receivers 623-0685 NC809DBB Button reset point c/w sounder and braille label MAGNETIC RESET KEYS For use with all magnetic call points, monitoring points and reset points 623-0074 NC803M/10 Pack of 10 magnetic reset keys ANCILLARY CALLING DEVICES Generate standard calls via a call point’s remote socket 623-0019 NC805C/6 1.8m (6ft) tail call lead 623-0020 NC805C/14 4.2m (14ft) tail call lead 623-0419 NC805D 1.2 to 3.6m (4 to 12ft) coiled tail call lead 620-0334 NC805P Hand/foot operated pneumatic pad (requires 1 x NC805AS) 620-0332 NC805AS Remote air switch for NC805P 623-0432 NC805MD Portable movement detector MISCELLANEOUS 800 SERIES DEVICES Generate standard calls via a call point’s remote socket 623-0464 NC899KD Area isolator, can be used to isolate areas/zones 623-0463 NC884DE Emergency 5:1 input expander, can be used to provide area/zonal indication 618-0155 NC885 Standard 5:1 input expander, can be used to provide area/zonal indication 623-0163 NC889 Call latch module, can trigger a standard call from a n/o or n/c switch 623-0462 NC889ERM Multi-purpose call latch module, can trigger a standard and/or an emergency call from a n/o or n/c switch 623-0388 NC883D 12V relay unit, can be used to switch sirens, strobes, etc. 623-0461 NC848/50 50 x anti-tamper screws 623-0460 NC947 Anti-tamper Allen key, for use with anti-tamper screws 386 NURSECALL/DISABLED TOILET ALARM SYSTEMS (continued) Code C-TEC DISABLED PERSONS TOILET ALARM KITS DISABLED PERSONS TOILET ALARMS/SINGLE ZONE CALL SYSTEM KITS Include everything required for a reliable and easy to install disabled persons toilet alarm system (except cable and fixings). 623-0263 NC951 disabled persons toilet alarm kit, c/w battery back-up c/w NC942B call controller, NC807C ceiling pull, NC806CS overdoor light & sounder, NC809DBB reset point & sounder, NC949 disabled wc sticker 623-0371 NC951/SS Stainless steel disabled persons toilet alarm kit c/w NC941/SS call controller, NC807C plastic ceiling pull, NC806CS/SS s/steel overdoor light & sounder, NC809DB/SS s/steel reset point & sounder, NC949 disabled wc sticker C-TEC 800 SERIES CALL SYSTEM SINGLE ZONE EMERGENCY INDICATOR PANELS C/W 12V PSU Can indicate standard and/or emergency calls 623-0690 NC942 Single zone 140mA call controller c/w psu, reset/mute buttons & relay 623-0691 NC942B Single zone 140mA call controller c/w psu, reset/mute buttons, relay & on-board battery back-up 623-0380 NC941 Single zone 250mA double gang call controller, c/w psu & reset button 623-0381 NC941/SS Single zone 250mA double gang call controller, c/w psu & reset button (s/steel) 623-0403 NC941B Battery back-up kit for NC941 4-8 ZONE EMERGENCY INDICATOR PANELS C/W MUTE & RESET BUTTONS, REQUIRE 12V PSU Can indicate standard and/or emergency calls 623-0296 NC944 Four zone double gang call controller 623-0297 NC930 12V 250mA PSU for up to two NC944s 623-0077 NC925B1 12V 1A PSU for up to three NC944s 623-0386 NC944/SS Four zone double gang call controller (s/steel) 623-0382 NC930/SS 12V 250mA PSU for up to two NC944/SS (s/steel) 10 TO 30 ZONE EMERGENCY INDICATOR PANELS C/W 12V PSU, BATTERY AND MUTE BUTTON Can indicate standard and/or emergency calls 623-0278 NC812KE 10 zone Emergency master panel c/w PSU & battery 623-0276 NC822KE 20 zone Emergency master panel c/w PSU & battery 623-0031 NC832KE 30 zone Emergency master panel c/w PSU & battery Repeater panels and larger master panels available to order 10 TO 30 ZONE STANDARD INDICATOR PANELS C/W 12V PSU Can indicate standard calls only 623-0001 NC810K 10 zone Standard master panel c/w PSU 623-0002 NC820K 20 zone Standard master panel c/w PSU 623-0003 NC830K 30 zone Standard master panel c/w PSU Repeater panels and larger master panels available to order OVERDOOR LIGHTS AND SOUNDERS Can be used to increase call indication levels 623-0012 NC806C Overdoor light 623-0383 NC806C/SS Overdoor light (s/steel version) 623-0258 NC806CS Overdoor light with sounder 623-0384 NC806CS/SS Overdoor light with sounder (s/steel version) 623-0289 NC887D Switchable sounder 623-0290 NC888D Remote sounder STANDARD CALL POINTS, MONITORING POINTS & CEILING PULLS Can generate standard calls only 623-0298 NC802DB Standard call point, button reset c/w remote socket 623-0265 NC802DM Standard call point, magnetic reset c/w remote socket 623-0013 NC807C Ceiling pull unit, no on-board reset, no remote socket 623-0267 NC894DKB Monitoring point, button reset, no remote socket 623-0266 NC894DKM Monitoring point, magnetic reset, no remote socket 387 C-CALL NURSECALL/DISABLED TOILET ALARM SYSTEMS (continued) Code CALL WAITING ROOM SYSTEM Waiting Room Systems C-TEC C-CALL WAITING ROOM CALL SYSTEM • • • Attractive slimline indicator panels with personalised self-adhesive labels Available in self-resetting or manual reception reset formats Durable desk and wall mounting call pushes with call confirmation LEDs C-CALL SELF-RESETTING DISPLAY PANELS 623-0172 NC905KT 2 zone self-resetting display panel 623-0171 NC906KT 4 zone self-resetting display panel 623-0208 NC907KT 6 zone self-resetting display panel 623-0207 NC925C Double insulated PSU, one required per system C-CALL RECEPTION PANELS 623-0067 NC911K 10 zone reception panel 623-0206 NC921K 20 zone reception panel C-CALL MANUAL RESET RECEPTION PANELS 623-0205 NC912K-5 5 zone resettable reception panel c/w psu 623-0204 NC912K-10 10 zone resettable reception panel c/w psu 623-0195 NC912K-15 15 zone resettable reception panel c/w psu C-CALL CALL PUSHES, OVERDOOR LIGHTS AND REMOTE SOUNDERS 623-0165 NC917L Call push (latching or non-latching) 618-0075 NC915L Desk push/4ft lead (latching/non-latching), requires NC920 623-0196 NC920 Wall socket, for use with NC915L desk push 623-0012 NC806C Overdoor light 623-0290 NC888D Remote sounder 388 NURSE CALL/DISABLED TOILET ALARM SYSTEMS (continued) Code VENTCROFT 623-0632 VPA-200P STANDARD DISABLED TOILET KIT 623-0635 VPA-BB1 BACK UP BATTERY UNIT 623-0639 VPA-ODI OVERDOOR TWIN LED & SOUNDER 623-0640 VPA-220P PREMIER DISABLED TOILET KIT 623-0641 VPA-PC PULLCORD 623-0642 VPA-RP REMOTE RESET POINT 389 ADDRESSABLE CALL SYSTEM Code C-TEC QUANTEC ADDRESSABLE CALL SYSTEM • • • • • • • • • Multiple call levels - standard call, help required (assist), emergency and optional infrared staff attack Up to 256 network devices per system Quantec Controller is now programmable via a sophisticated upload/download PC program or by its front panel controls Up to 45 custom place names per system (in addition to an extensive library of pre-loaded place names) Flexible call routing - allows the system to be configured to suit a building’s exact operational requirements Full monitoring of all network devices Staff presence, call accept, manual and automatic call divert facilities New optional Quantec Surveyor software allows detailed data analysis reports to be sent direct to a PCs desktop on criteria such as longest calls, busiest shifts, average call response times, etc. Now with HTM2015 capability (requires specially designed third-party switch assemblies used in conjunction with our new range of Quantec universal devices) QUANTEC CONTROLLERS, DISPLAYS, SOUNDERS AND OVERDOOR LIGHTS 623-0359 QT601-2 Quantec controller 604-0167 AFP385 Flush bezel for Quantec controller 623-0397 QT707 Quantec PC programming software c/w lead (Windows) 604-0486 SAF7070000 2m programming lead only 623-0711 QT707S Quantec Surveyor Data Management Software c/w wall socket and lead 623-0358 QT603 Quantec network splitter (installation aid) 623-0357 QT608C Quantec corridor display, with controls 623-0342 QT606 Quantec overdoor light 623-0341 QT606A Quantec addressable overdoor light 623-0340 QT688 Quantec addressable sounder 623-0700 QT688/2 Quantec high-output 82dB addressable sounder (with optional HTM2015 capability - requires QT423 configurator) QUANTEC CALL POINTS, MONITORING POINTS, CEILING PULLS, INFRARED CEILING RECEIVERS AND RADIO RECEIVERS The QT602 call points listed below include remote sockets. Magnetic reset call points & call points without remote sockets are also available. 623-0355 QT602 Quantec call point, button reset 623-0354 QT602S Quantec call point, button reset with sounder 623-0353 QT602R Quantec call point, button reset with infrared receiver 623-0352 QT602RS Quantec call point, button reset with sounder & infrared receiver 623-0347 QT602D Quantec slave call point 623-0339 QT607 Quantec ceiling pull unit 623-0346 QT604 Quantec monitoring point, button reset 623-0344 QT302RX Quantec master infrared ceiling receiver 623-0343 QT302RXS Quantec slave infrared ceiling receiver 623-0630 QT422RX Quantec Mk2 radio receiver (compatible with QT412 range transmitters) 623-0631 QT422RXEA Quantec Mk2 radio receiver extension aerial 623-0629 QT421 Single gang monitored heartbeat plate (checks integrity of QT422RX radio receivers) 390 QUANTEC DUAL ACTION TRANSMITTERS QUANTEC ADDRESSABLE CALL SYSTEM ADDRESSABLE CALL SYSTEM (continued) Code QUANTEC UNIVERSAL DEVICES 623-0708 QT611 Quantec multi-purpose programmable device (unplated), allows third-party switch assemblies & indicators to be interfaced to Quantec 623-0703 QT612 Quantec relay output device (unplated), a zone-specific relay output to trigger third-party strobes, sounders, auto-diallers, etc. 623-0709 QT613 Quantec zonal indicator driver device (unplated), can be used to drive third-party LED indicating devices 623-0710 QT614 Quantec bedhead light dimmer interface (unplated) 623-0620 QT423 Quantec configurator (required to program QT611/612/613/614 devices) QUANTEC DUAL ACTION INFRARED/RADIO TRANSMITTERS Can be used to remotely trigger compatible Quantec infrared receivers and Quantec radio receivers QT412RXA Mk2 Dual action infrared/radio transmitter (Configured for push for attack/pull for attack) 623-0618 QT412RXCA Mk2 Dual action infrared/radio transmitter (Configured for push for call/pull for attack) 623-0620 QT423 Configurator for QT412RXU 623-0621 QT424/1 Single way charging unit for QT412 range dual action transmitter 623-0617 QT424/10 Ten way charging unit for QT412 range dual action transmitters ANCILLARY CALLING DEVICES, PRINTERS AND PAGING EQUIPMENT 623-0019 NC805C/6 1.8m (6ft) tail call lead 623-0020 NC805C/14 4.2m (14ft) tail call lead 623-0419 NC805D 1.2-3.6m (4-12ft) tail call lead 623-0332 QT600P Quantec printer kit incl. printer, lead & wall socket 623-0331 QT600S Quantec printer/paging wall socket 623-0399 DP874QA 400m Transmitter for alpha pagers, lead & wall socket 623-0500 DP876D Display pager aerial, extends transmitting range to 1500m 623-0501 DP876B Mounting bracket for DP876D 623-0502 DP876F 15 metre low loss cable for DP876D 623-0400 DP877QA 32 character alphanumeric display pager, group A 391 Addressable Call System 623-0623 PDA RANGE INDUCTION LOOP AMPLIFIERS INDUCTION LOOP HEARING SYSTEMS Code C-TEC PDA RANGE AUDIO FREQUENCY INDUCTION LOOP SYSTEMS The widest range of audio frequency induction loop equipment in the UK. • Can be used to help building managers and service providers comply with the • Disability Discrimination Act, BS8300 and the Care Standards Act. Can • be fitted by any competent electrician - no audio experience required. For ease of specification and installation, many of our induction loop amplifiers are available in kit format. Please note, loop cable is included in all ML1/K, PDA102 and DL50/K kits. For ‘AK’ range kits cable we recommend you use our 1mm2 LOOP2/W. For other loop amplifiers, please contact us for advice. All amplifiers (and kits) are supplied with an ‘induction loop in use’ sticker. Portable induction loop systems 623-0465 623-0524 623-0543 623-0542 623-0583 623-0567 PL1/K1 Portable loop system (in a cardboard storage case) c/w 1m (sq) portable loop amplifier and plugtop charger PL1/K2 Portable loop system with AFILS tester (in a cardboard storage case) c/w amplifier, charger, loop listener/field strength meter and headphones PL1/K3 Portable loop system (in a plastic storage/carry case) c/w 1m (sq) portable loop amplifier and plugtop charger PL1/K4 Portable loop system with AFILS tester (in a plastic storage/ carry case) c/w amplifier, charger, loop listener/field strength meter and headphones PL1/BATT Replacement battery for PL1 amplifier TEAR-P Spare self-adhesive “Induction Loop Available” sticker 1.2m (sq) counter induction loop kits 623-0466 623-0379 ML1/K Wall-mounting counter induction loop kit c/w 1.2m (sq) double gang loop amplifier, AMT microphone & TX2 counter loop PDA102C Free-standing counter induction loop kit c/w 1.2m (sq) loop amplifier, AMT microphone & TX121 counter loop 1.2m (sq) vehicle induction loop kits 623-0718 623-0719 VL1/B1 12V vehicle loop amp c/w 1.2m (sq) 12V, mini-loop amp, TX2 loop, AMT mic. & AL8 fused cigarette lighter adapter VL1/B2 24V vehicle loop amp c/w 1.2m (sq) 12V, mini-loop amp, TX2 loop, AMT mic. VL1PSU24 24V to12V converter Induction loop amplifiers & kits 20m (sq) induction loop amplifier 623-0467 ML1 Mini 20m (sq) wall-mounting double gang induction loop amplifier 50m (sq) small room induction loop kits 623-0433 623-0378 623-0582 623-0377 DL50/K Domestic induction loop kit c/w 50m (SQ) free-standing loop amplifier, AMT microphone, SCART lead & loop cable PDA102L Small room induction loop kit (tie/desk mic. version) c/w 50m (sq) free-standing loop amplifier, AMT microphone & 30m loop cable PDA102R Small room induction loop kit (plated mic. version) c/w 50m (sq) free-standing loop amplifier, AMP plated microphone & 30m loop cable PDA102S TV lounge induction loop kit c/w 50m (sq) free-standing loop amplifier, APS scart lead, APL connection plate & 30m loop cable 120m2 induction loop amplifiers & kits 620-0257 623-0376 623-0375 623-0468 623-0374 623-0469 623-0568 623-0439 623-0470 623-0584 623-0471 392 PDA200E 120m (sq) wall-mounting loop amplifier AKM1 Meeting/seminar room loop kit c/w 120m (sq) amplifier, APM omni-directional mic plate/cable AKL1 Lecture room induction loop kit c/w 120m (sq) amplifier, AMT tie/desk mic, AML lectern mic, 2 x APJ plate/cable AKT1 TV/music lounge induction loop kit c/w 120m (sq) amplifier, AMH handheld mic, APS scart lead, APJ plate/cable, APL plate/cable AKW1 Place of worship induction loop kit 1 c/w 120m (sq) amplifier, AML lectern mic, APJ plate/cable, APL plate/cable AKW2/L Place of worship loop kit 2 (lavalier mic. version) c/w 120m (sq) amplifier, plate/cable AMR/L AMR/LA lavalier radio mic, APQM plate/cable, 2 x APXM AKW2/H Place of worship loop kit 2 (handheld mic. version) c/w 120m (sq) amplifier, AMR/HA handheld radio mic, APQM plate/cable, 2 x APXM plate/cable AKR1 Waiting room loop kit c/w 120m (sq) amplifier, APL plate/cable AKH1/L Health and fitness club loop kit (lavalier mic version) c/w 120m (sq) amplifier, plate/cable AMR/LA lavalier radio microphone, APQM plate/cable & APL AKH1/H Health and fitness club loop kit (handheld mic version) c/w 120m (sq) amplifier, AMR/HA handheld radio microphone, APQM plate/cable & APL plate/cable AKU1 Retail unit induction loop kit c/w 120m (sq) amplifier, AML lectern microphone & APJ plate/cable balanced line input balanced line input standard two-pair audio cable (Belden 8723 or similar) APM APL SELF-CONTAINED DUAL PHONO OMNI-DIRECTIONAL MIC LINE LEVEL PLATE SCART INPUT FROM TV (i.e. APS LEAD) INDUCTION LOOP TESTING EQUIPMENT API PDA200E INDUCTION LOOP AMPLIFIER ‘AFILS ACTIVE’ INDICATOR APJ APXL APXM 3.5MM MONO JACK PLATE XLR LINE LEVEL PLATE XLR MICROPHONE PLATE MICROPHONE (i.e. AMT, AMH, AML or AMD) AUDIO FEED FROM MIXING DESK MICROPHONE (i.e. AMP) APQ 1 /4” STEREO JACK PLATE MICROPHONE (i.e. AMR) TYPICAL OUTREACH PLATE WIRING INDUCTION LOOP HEARING SYSTEMS (continued) Code Professional induction loop amplifiers 623-0606 623-0605 623-0607 623-0669 623-0686 PDA200/2 200m (sq) free-standing professional induction loop amplifier PDA500/2 500m (sq) free-standing professional induction loop amplifier PDA1000/2 900m (sq) free-standing professional induction loop amplifier PDA/RM 19" rack mount kit for PDA Pro-Range amplifier PDA/WM Wall mount kit for PDA Pro-Range amplifier Outreach plate audio input extension system Allows the connection of multiple microphone or line level inputs to a PDA Range amplifier via a range of specially designed single gang audio connector plates. A maximum of 10 plates (any mix) can be daisychained to the amplifier’s ‘Outreach’ socket* using standard two pair audio cable such as Belden 8723. *DL50 amps do not have an outreach socket. 623-0446 623-0474 623-0475 623-0570 623-0476 623-0477 623-0412 623-0746 623-0478 623-0479 623-0572 N NEW APJ 3.5mm mono jack plate, for connection of AMT, AMH, AML or AMD microphones APL Line level audio plate, for connection of APS SCART lead or other line level audio feeds APQM 6.35mm stereo jack plate, for connection of AMR/L and AMR/H radio microphone kits APQL 6.35mm stereo jack plate, for connection of line level feeds from mixing desks, etc APXM XLR mic level plate, for connection of AMP microphone APXL XLR line level plate, for connection of mixing desk line level feeds APM Omni-directional plated microphone for wall/ceiling/desk mounting APXO 3 pin XLR balanced line output plate, connected an Outreach chain to 3rd party equipment API AFILS active indicator light APS SCART to double phono lead (for use with APL plate) BELDEN/25 25m Belden 8723 four core screened cable for outreach network Microphones N NEW APM Omni-directional plated microphone for wall/ceiling/desk mounting AMT Tie/desk microphone for direct connection to ML1, DL50, PDA102, PDA200E, PL1, PDA PRO-RANGE & APJ outreach plate AMH Handheld microphone for direct connection to ML1, DL50, PDA102, PDA200E PL1, PDA PRO-RANGE & APJ outreach plate AML Long-stemmed Lectern microphone for direct connection to ML1, DL50, PDA102, PDA200E, PL1, PDA PRO-RANGE & APJ outreach plate AMLS Short-stemmed Lectern microphone for direct connection to ML1, DL50, PDA102, PDA200E, PL1, PDA PRO-RANGE & APJ outreach plate AMD Long-stemmed Desktop microphone for direct connection to ML1, DL50, PDA102, PDA200E, PL1, PDA PRO-RANGE & APJ outreach plate AMDS Short-stemmed Desktop microphone for direct connection to ML1, DL50, PDA102, PDA200E, PL1, PDA PRO-RANGE & APJ outreach plate AMD/P Desktop microphone, push to talk AMP Professional handheld microphone for direct connection to PDA200E or APXM outreach plate (requires AXLR lead) AMR/LA Levalier radio microphone (173.8 KHz), with microphone, receiver, transmitter & psu. For direct connection to PDA200E or APQM outreach plate AMR/LB Levalier radio microphone (174.6 KHz), with microphone, receiver, transmitter & psu. For direct connection to PDA200E or APQM outreach plate AMR/HA Handheld radio microphone (173.8 KHz) , with microphone, receiver, transmitter & psu. For direct connection to PDA200E or APQM outreach plate AMR/HB Handheld radio microphone (174.6 KHz), with microphone, receiver, transmitter & psu. For direct connection to PDA200E or APQM outreach plate PRO45 Hanging ambient microphone for PDA Pro-Range or APXM plate Induction loop testing equipment BS8300 (the code of practice for the design of buildings and their approaches to meet the needs of disabled people) states that all loop systems should conform to BS7594 & EN60118-4. The best way to ensure compliance is to use a PDA Range pink noise generator and FoSmeter magnetic field strength meter. 623-0485 623-0486 623-0487 623-0488 623-0573 623-0489 623-0490 623-0491 PNGN Pink noise generator (requires PP3 battery and AL1, 2 or 3 connection lead) AHHM FoSmeter magnetic field strength meter (requires PP3 battery) AMPN FoSmeter+ combined pink noise generator & magnetic field strength meter (requires PP3 battery and AL1, 2 or 3 connection lead) AHHM/H FoSmeter+ combined magnetic field strength meter & loop listener (requires PP3 battery and headphones) HEAD1 32 Ohm headphones for use with AHHM/H AL1 3.5mm jack to 3.5mm jack lead (connects PNGN to APJ plate) AL2 3.5mm jack to double phono lead (connects PNGN to APL plate) AL3 3.5mm jack to pre-cut end lead - for customer’s own connection of PNGN to a compatible line level input Miscellaneous induction loop ancillaries 623-0492 623-0493 623-0494 623-0577 623-0448 623-0495 623-0574 623-0716 623-0496 FLAT2005 1.0mm (sq) copper tape (for under carpet loops) 100m FLAT3005 1.5mm (sq) copper tape (for under carpet loops) 100m TAPE White synthetic fibre tape (to protect flat loop cable) 50m LOOP2/W 100m reel of 1.0mm (sq) single core white loop cable APT Loop connector plate (for the termination of induction loop cable) AXLR XLR to XLR lead (used to connect AMP mic to APXM plate) LEST 100V line (i.e. PA system output) to 0db (77mv line level) converter APPS Overspill reduction phase shifter TEAR10 Pack of 10 self-adhesive ‘induction loop in use’ stickers 393 Induction Loop Systems 623-0412 623-0481 623-0482 623-0483 623-0687 624-0028 623-0688 623-0747 623-0484 623-0410 623-0712 623-0569 623-0714 623-0689 DISABLED REFUGE SYSTEMS Code TYPE A FIRE TELEPHONE OUTSTATIONS 620-0418 THS1-E/MK4 Red telephone handset with key (fire telephone text on window) 620-0417 THS1-ET/MK4 Red telephone handset with handle & T bar (fire telephone text on window) 620-0416 T-BEZ Red flush bezel for THS1-E or THS1-ET 620-0415 THS/MK4 Red desk mount telephone handset TYPE B DISABLED REFUGE (HANDSFREE) OUTSTATIONS N N N NEW 620-0875 EVC302F Handsfree duplex EVC outstation, stainless steel, flush mounting NEW 620-0876 EVC302S Handsfree duplex EVC outstation, stainless steel, surface mounting NEW 620-0881 BF359/1 Weatherproof enclosure, IP66, steel, non-locking (for EVC302F/S) C-TEC SigTEL COMPACT EMERGENCY VOICE COMMUNICATION / DISABLED REFUGE SYSTEM • Meets and exceeds the requirements of BS 5839 part 9 • Ideal for all disabled refuge and fire telephone applications • New Compact 1-8 line (expandable to 16) wall-mounting central control unit saves valuable desk and floor space in crowded control rooms • Type B stainless steel ‘Disabled Refuge’ outstations offer true duplex hands-free speech - flush, surface and weatherproof versions are available • Type A ‘Fire Telephone’ outstations come in locking or non-locking red steel cabinets and offer true duplex speech - semi-flush, surface and weatherproof versions are available. • Unique ‘auto-learn’ facility allows fast network set up • All extensions can be named with user-defined text of up to 15 characters • Fully monitored hardware and software • System operates at 24 VDC. In the event of mains failure, operation can be maintained for 24 hours (standby) and 3 hours (in use) using 2 x 12V 7Ahr batteries • Optional line tester allows cable faults to be checked prior to equipment connection • Ideal for hotels, shopping malls, office blocks, transport terminals, banks, sports stadia, entertainment complexes, auditoria, etc. SIGTEL COMPACT 1-16 LINE COMBINED DIAL/CONTROL UNITS N N NEW 620-0873 ECU-8 8 Line Master EVC control unit c/w line cards, handset and display, wall-mounting, needs BC286/2 batteries NEW 620-0874 ECU-8S 8 Line Slave EVC expansion unit (expands ECU-8 to 16 lines max.), wall-mounting, max. one ECU-8S slave per ECU-8, no batteries required N N N N NEW 604-0167 AFP385 Grey flush bezel for ECU-8 or ECU-8S NEW 620-0908 ECU721 Network driver card - allows up to 15 SigTEL Compact ECU-8 dial/control units to be interlinked NEW 623-0398 BC286/2 24V 7AHr VRLA battery pack NEW 620-0405 FITT EVC line tester C-TEC SigTEL 16-128 LINE CONTROL & DIAL UNITS & ANCILLARIES • A modular 16-128 line emergency voice communication system - ideal for larger disabled refuge and fire telephone applications 394 620-0414 CCU-16 16 line master control unit c/w fault display, needs line cards 620-0412 SCU-16 16 line slave control unit c/w fault display, needs line cards 620-0413 LC2 Line Card for Type A fire telephone outstations, (2 lines per card - up to 8 cards per CCU-16/SCU-16) 620-0880 LC3 Line Card for Type B disabled refuge outstations, (2 lines per card - up to 8 cards per CCU-16/SCU-16) 623-0398 BC286/2 24V 7AHr VRLA battery pack 620-0411 SVMM Message card for CCU (optional) 620-0410 SVMM/C Custom message card for CCU (optional) 620-0409 ECU-32 Desk control unit c/w handset & display, 32 line 620-0408 ECU-64 Desk control unit c/w handset & display, 64 line 620-0407 ECU-128 Desk control unit c/w handset & display, 128 line 620-0406 ECUWMB Wall mount bracket for ECU 620-0404 catCON Adaptor box (for conversion of FP200 to CAT5) 620-0402 XSB Xenon strobe, blue, 12V 620-0782 XSA Xenon strobe, amber, 12V 620-0403 SDM Xenon strobe driver module, 12V ADI-GARDINER-SUPPLIER/PRODUCT 2008 TRAINING SCHEDULE Location Beckton Salford Birmingham Eastleigh Glasgow Feb 12th Mar Apr May 8th June July 2nd Aug Sept Oct 1st Nov 4th Dec 15th 3rd 18th 18th 18th Fire Alarm Panels 2 Wire Fire Alarm Systems Refuge/Sigtel/Quantec Systems Audio/Visual Alarm Equipment Test Equipment Point Detectors/Optical Beams 3rd 3rd 3rd 5th 29th 5th 24th 20th 20th 20th Fire Alarm Panels 2 Wire Fire Alarm Systems Refuge/Sigtel/Quantec Systems Audio/Visual Alarm Equipment Test Equipment Point Detectors/Optical Beams 5th Fire Alarm Panels 2 Wire Fire Alarm Systems Refuge/Sigtel/Quantec Systems Audio/Visual Alarm Equipment Test Equipment Point Detectors/Optical Beams 7th 4th 4th 11th 4th 7th 15th 15th 15th 23rd 23rd 23rd 4th 2nd 6th 13th 3rd 30th 30th 30th 5th 5th 5th 20th Fire Alarm Panels 2 Wire Fire Alarm Systems Refuge/Sigtel/Quantec Systems Audio/Visual Alarm Equipment Test Equipment Point Detectors/Optical Beams 3rd 2nd 4th 12th 23rd 15th 2nd 2nd 2nd 26th 26th 26th 18th Fire Alarm Panels 2 Wire Fire Alarm Systems Refuge/Sigtel/Quantec Systems Audio/Visual Arlarm Equipment Test Equipment Point Detectors/Optical Beams 3rd 14th 11th 21st 18th 18th 18th 8th 8th 8th Courses begin at 9:00am and finish at 4:30pm, lunch is provided between 12:30pm and 1:30pm (Please inform ADI-GARDINER of any special dietary requirements two weeks prior to a training course) For further information on each course, please contact Mark Wild on (01706) 510515. Don’t forget to log onto www.adi-gardiner.co.uk for news and updates on the latest ADI-GARDINER training initiatives! Morley IAS Rafiki C-TEC Apollo detectortesters Fire Beam Apollo detectortesters Klaxon Adv Electron Kentec ADI-GARDINER ICEL Emergency Lighting Courses Location Brentwood Birmingham Bristol Newport Enfield Plymouth Glasgow Ipswich Manchester Newcastle Poole Gatwick York Course Emergency Lighting Emergency Lighting Emergency Lighting Emergency Lighting Emergency Lighting Emergency Lighting Emergency Lighting Emergency Lighting Emergency Lighting Emergency Lighting Emergency Lighting Emergency Lighting Emergency Lighting Jan Feb Mar Apr May June July Aug Sept 19th Oct Nov Dec 7th 14th 21st 15th 4th 4th 5th 12th 10th 6th 20th 23rd 30th 21st 2nd 5th 2nd 13th 15th 10th 3rd Courses to run from 8:45am - 5:00pm, with lunch provided between 12:30pm and 1:30pm HOW TO BOOK 1. Simply visit the training section of the ADI-GARDINER website - www.adi-gardiner.co.uk/training.asp 2. Follow the links for the ICEL Training Courses to the ICEL on-line booking facility 3. Make a fast and secure booking for the date of your choice The Industry Committee for Emergency Lighting Ltd ICEL Emergency Lighting ONE DAY Training Course - £130 + VAT This one day course has been subsidised by ADI-GARDINER, and details the essential aspects of BS 5266 Parts 1, 7 and 8. BS 5266 Part 1 was revised in 2005 and the course includes this material with particular reference to the new test and servicing recommendations. The course is split into sections with a test after each, with those passing qualifying for an ICEL certificate. Delegates will also put into practice some of the course material and mark up a plan with appropriate emergency lighting. SECTIONS: Section A Background and legislation for emergency lighting. Section B Exit signs and illuminance requirements. Section C Maintained lighting, special requirements, labelling, recharge times and approval certification. Section D Design procedures for emergency lighting, including integrity and spacings. Section E High risk task areas, response times, correction factors and conversions. Section F Disability glare, installation, testing, service and maintenance for emergency lighting systems. This course qualifies for 6.5 hours of CPD (Continuing Professional Development). Ideally delegates will have been employed in a role that has given them adequate experience of emergency lighting systems (at least one year). 395 ADI-GARDINER – Supplier/Product ICEL 2008 Training Schedule Norwich Course Jan Fire Alarm Panels 2 Wire Fire Alarm Systems Refuge/Sigtel/Quantec Systems Audio/Visual Alarm Equipment Test Equipment Point Detectors/Optical Beams 396 FIA 2008 Training Schedule Location Course Brentwood UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 Birmingham Bristol Newport Enfield Glasgow Ipswich Manchester Bournemouth Gatwick York Feb Mar June July Aug Sept Oct Nov Dec 28th 29th 26th 27th 12th 24th 5th 22nd UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 19th UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 5th 9th 2nd 3rd 1st 15th 11th 3rd 16th 16th 2nd 3rd 22nd 4th 27th 19th 2nd 7th 8th 12th 16th 18th UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 6th UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 6th UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 5th 24th 22nd 23rd 6th 20th 5th 23rd 15th 22nd 23rd 9th 10th 10th 4th 13th 8th 10th 18th 15th 16th 22nd 5th 4th 8th 11th 21st 17th 24th 28th 29th 19th 3rd 4th 26th 18th 13th UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 10th UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 22nd 15th 16th 26th 9th 11th 12th 4th 21st 20th 19th UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 UNIT 9 UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 May 23rd 4th UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 Apr 26th 9th 10th 16th 14th 17th 15th 1st 7th 3rd 4th 22nd 1st 23rd 11th Courses begin at 9:00am and finish at 4:30pm, lunch is provided between 12:30pm and 1:30pm This joint FIA/ADI GARDINER initiative is subsidised by ADI-GARDINER for our customers. HOW TO BOOK 1. Simply visit the training section of the ADI-GARDINER website - www.adi-gardiner.co.uk/training.asp 2. Follow the links for the FIA Training Courses to the FIA on-line booking facility 3. Make a fast and secure booking for the date of your choice UNIT 1 Fire Detection Design Course £130 +VAT per delegate UNIT 2 Advanced Detection Design Course £130 +VAT per delegate UNIT 3 Advanced Alarm Design Course £130 +VAT per delegate UNIT 4 Installation and Testing Course £130 +VAT per delegate UNIT 5 Fire Alarm Maintenance Course £130 +VAT per delegate UNIT 6 Advanced Commissioning Course £130 +VAT per delegate UNIT 9 Fire Risk Assessment -Responsibilities & Procedures £130 +VAT per delegate NOTE: UNIT 9 PLEASE NOTE THAT DELEGATES WILL NOT BE QUALIFIED TO UNDERTAKE RISK ASSESSMENTS UPON THE COMPLETION OF THIS COURSE NOTE: UNIT'S 2 & 3 COURSES RUN IN CONJUNCTION AND ARE HELD ON CONSECUTIVE DAYS 397 ADI-GARDINER – FIA Training Schedule – 2008 Newcastle Jan 398 Introduction Changes to British Standards along with the introduction of the CFOA policy and the soon to be launched Regulatory Reform (Fire Safety) Order have/will bring about changes in the British Fire Industry, not least the overriding requirement for companies and personnel working within the industry to not only be competent but also to prove their competence. ADI-GARDINER Fire Division has entered a joint initiative with three of the Fire Industries leading bodies to promote the “Proof of Competence Roadmap CD-ROM” to ADI-GARDINER Fire Customers. Overview of the scheme ADI-GARDINER Fire has produced a “Proof of Competence Roadmap” CD-ROM sponsored by FIA, BAFE and BSI. The CD-ROM contains full details of schemes run by each of the three trade bodies as well as a training programme and application form for the third party certification scheme ‘SP203’, all of which is presented in the form of a time-table (Roadmap). The scheme involves customers/companies purchasing the “Proof of Competence” Roadmap CD-ROM. Your ADI-GARDINER Regional Fire Sales Manager will then sit down with you and assess your training to date and your future training requirements, planning this into the time-table (Roadmap) and booking courses as appropriate. As your company progresses through its training programme it will build up the CD-ROM folder with certificates of training courses sat and passed, thereby building up a record of “Proof of Competence”. Benefits to Companies working in the Fire Industry With legislation and policies calling for competent persons, and proof of competence of personnel and companies working within the fire industry, we feel this is the most cost effective way for companies to reach this aim. For further details, please contact Mark Wild on 01706 510515 or e-mail mark.wild@adi-gardiner.co.uk 200-0092 Proof of Competence “Roadmap” CD-ROM 399 £25.00 The Roadmap The “Proof of Competence” CD-ROM, complete with certificates of courses sat and passed along with accreditation to the BSI third party certification scheme SP203, which enables the use of the BSI kite-mark, will allow your company to prove its competence to potential and existing clients (specifiers, project management companies, contract managers, facilities managers and local authority building managers to name just a few). 400