Title page
Alcatel-Lucent
Base Station Subsystem | B12
Modify Logical Parameter Using MLU
9YZ-03803-1860-RJZZA
Issue 2 | May 2013
Legal notice
Legal notice
Alcatel, Lucent, Alcatel-Lucent and the Alcatel-Lucent logo are trademarks of Alcatel-Lucent. All other trademarks are the property of their respective
owners.
The information presented is subject to change without notice. Alcatel-Lucent assumes no responsibility for inaccuracies contained herein.
Copyright © 2013 Alcatel-Lucent. All rights reserved.
Note:
Not to be used or disclosed except in accordance with applicable agreements.
Contents
About this document
vii
Purpose ............................................................................................................................................................................................ vii
Reason for reissue
....................................................................................................................................................................... vii
vii
New in this release
...................................................................................................................................................................... vii
vii
Intended audience
...................................................................................................................................................................... viii
viii
Supported systems
..................................................................................................................................................................... viii
viii
How to use this document ....................................................................................................................................................... viii
viii
Prerequisites ................................................................................................................................................................................. viii
viii
Conventions used
....................................................................................................................................................................... viii
viii
Related information
Document support
..................................................................................................................................................................... ix
ix
........................................................................................................................................................................ ix
ix
Technical support .......................................................................................................................................................................... ix
ix
How to order ................................................................................................................................................................................... ix
ix
How to comment ........................................................................................................................................................................... ix
ix
1
Overview
Overview ...................................................................................................................................................................................... 1-1
1-1
Presentation ................................................................................................................................................................................. 1-1
1-1
Preparation
.................................................................................................................................................................................. 1-5
1-5
Scheduling ................................................................................................................................................................................... 1-6
1-6
Telecom / Supervision Outage and Operating Impact ................................................................................................. 1-7
1-7
Resources ..................................................................................................................................................................................... 1-8
1-8
2
Scenario
Overview ...................................................................................................................................................................................... 2-1
2-1
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
iii
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Contents
....................................................................................................................................................................................................................................
Before Going Onsite
Preparation Before Going Onsite ........................................................................................................................................ 2-3
2-3
Before You Start
Preparations Before You Start .............................................................................................................................................. 2-4
2-4
Scenario Description
Scenario Description Overview ........................................................................................................................................... 2-5
2-5
Initial Checks .............................................................................................................................................................................. 2-6
2-6
Create Backup PRC
................................................................................................................................................................. 2-8
2-8
Modify Parameters ................................................................................................................................................................. 2-10
2-10
Export Configuration
............................................................................................................................................................ 2-18
2-18
Import / Synchronize PRC .................................................................................................................................................. 2-20
2-20
Download MLU ...................................................................................................................................................................... 2-25
2-25
Activate MLU .......................................................................................................................................................................... 2-29
2-29
Final Checks ............................................................................................................................................................................. 2-31
2-31
Accept MLU ............................................................................................................................................................................. 2-32
2-32
Reverse Procedure without Accept
How to Perform Reverse Procedure without Accept ................................................................................................. 2-35
2-35
Reject / Logical Audit / Re-synchronize GPRS
.......................................................................................................... 2-36
2-36
O1: Activate Backup PRC ................................................................................................................................................... 2-39
2-39
Final Checks ............................................................................................................................................................................. 2-41
2-41
Reverse Procedure after Accept
Activate Backup PRC ........................................................................................................................................................... 2-43
2-43
Final Checks ............................................................................................................................................................................. 2-46
2-46
Parallel Checks
How to Perform Parallel Checks
...................................................................................................................................... 2-48
2-48
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
iv
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
List of figures
1-1
Files and Attributes Relevant to Logical Parameter Modifications
........................................................ 1-2
1-2
Modify Logical Parameters with OMC-R using MLU ................................................................................ 1-4
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
v
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
List of figures
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
vi
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
About this document
About this document
Purpose
This scenario describes how to perform a massive logical update to optimize the
performance and capacity of the network.
It describes how to:
•
•
Modify the frequency plan
Modify the hopping mode
•
•
Modify the logical parameters
Create / delete adjacencies and external cells.
Reason for reissue
Issue number
Reason for reissue
2
The following sections were updated:
1
•
“Download MLU” (p. 2-25)
•
“Accept MLU” (p. 2-32).
First official release of the document for B12.
New in this release
This section contains information about changes to the current document.
New features
None.
Other changes
None.
...................................................................................................................................................................................................................................
Alcatel-Lucent BSS
vii
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
About this document
....................................................................................................................................................................................................................................
Intended audience
This document is intended for:
•
•
•
Network modification planners
Operations and Maintenance technicians and systems designers
Operators who are responsible for carrying out the following O&M functions on
assigned BSSs.
As follows:
– Configuration
– Performance
– Fault Management.
Supported systems
This document applies to Release B12 of the BSS.
How to use this document
No specific recommendation applies regarding the way readers should read this
document.
Prerequisites
You must have a basic understanding of the following:
•
•
Planning
Including:
– Network architecture and reshuffling principles
– Scheduling.
Implementation.
Including:
– Alcatel-Lucent Operations and Maintenance (O&M) concepts for the BSS
– GPRS concepts
– 9153 OMC-R operating in Release B12.
Conventions used
This section gives information on conventions.
Vocabulary conventions
None.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
viii
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
About this document
....................................................................................................................................................................................................................................
Typographical conventions
The following typographical conventions are used in this document:
Appearance
Description
Italicized text
Emphasized information.
graphical user interface text
Text that is displayed in a graphical user interface or in a
hardware label.
Document reference,
9YZ-03803-1860-RJZZA
Related document that is referenced in the document.
Related information
None.
Document support
For support in using this or any other Alcatel-Lucent document, contact Alcatel-Lucent at
one of the following telephone numbers:
•
•
1-888-582-3688 (for the United States)
1-317-377-8618 (for all other countries)
Technical support
For technical support, contact your local Alcatel-Lucent customer support team. See the
Alcatel-Lucent Support web site (http://www.alcatel-lucent.com/support/) for contact
information.
How to order
To order Alcatel-Lucent documents, contact your local sales representative or use Online
Customer Support (OLCS) (http://support.alcatel-lucent.com)
How to comment
To comment on this document, go to the Online Comment Form (http://infodoc.alcatellucent.com/comments/) or e-mail your comments to the Comments Hotline
(comments@alcatel-lucent.com).
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
ix
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
About this document
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
x
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
1
Overview
1
Overview
Purpose
This Overview gives information needed by project managers and foremen, for
presentation to the customer and for site planning.
Contents
Presentation
1-1
Preparation
1-5
Scheduling
1-6
Telecom / Supervision Outage and Operating Impact
1-7
Resources
1-8
Presentation
Overview
This scenario defines how to perform a massive logical update to:
•
•
•
•
Modify the frequency plan
Modify the frequency hopping mode
Modify different logical parameters on cells
Create / delete / modify adjacencies and external cells.
These modifications optimize the performance and capacity of the network.
Note that BSC parameters cannot be modified via the MLU.
...................................................................................................................................................................................................................................
Alcatel-Lucent BSS
1-1
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Overview
Presentation
....................................................................................................................................................................................................................................
A frequency plan can cover a complete network, which can be under the control of
several OMC-Rs. An OMC-R is impacted if it contains cells directly modified by the
frequency plan, or cells that are in the neighborhood of modified cells. Analyzing the
impact on neighboring cells is essential in order to avoid losing handover relationships.
This method applies to both the 9120 BSC and the 9130 BSC Evolution.
Tip: If you do not have a thorough knowledge of the impacted cells, assume that all
the OMC-Rs of the network are impacted.
Non-Alcatel-Lucent OMC-Rs can also be impacted. Although updating such OMC-Rs
does not concern Alcatel-Lucent, it is mentioned in the scenario as a reminder.
The OMC-Rs export their frequency information in the 9153 OMC Configuration Import
/ Export (ACIE) format.
For more information about this format, refer to:
•
•
9153 OMC-R Configuration Import/Export Interface
9153 OMC-R Configuration Import/Export Interface: Supplementary Information.
Several comma-separated value (csv) files are generated, which cover the complete
configuration of the OMC-R.
Figure 1-1 Files and Attributes Relevant to Logical Parameter Modifications
Only five of these files and attributes are relevant for frequency modification. The
following table gives the names of the files and the relevant attributes.
File Name
Attributes
Cell.csv
Mode, CellInstanceIdentifier, CellAllocation, HoppingMode,
BSIdentityCode.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
1-2
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Overview
Presentation
....................................................................................................................................................................................................................................
File Name
Attributes
RnlBasebandTranceiver.csv
Mode, RnlBaseBandTranceiverInstanceIdentifier,
ListOfRadioChannels.
RnlFrequencyHoppingSystem.csv
ModeRnlFrequency, HoppingSystemInstanceIdentifier,
MobileAllocation, HoppingSequenceNumber.
Adjacency.csv
Mode, AdjacencyInstanceIdentifier, RnlAdjacencyType,
HoMargin, LinkfactorOn, HoMarginLevel, HoMarginQual,
HoPriorityLevel.
ExternalOmcCell.csv
ExternalCell.
Note: When using the 9159 NPO as the external tool, it recovers the OMC-R
configuration information automatically, usually on a daily basis. You can use the
most recent of these exported files to modify your logical parameters.
Cases
The following cases apply:
•
•
C1: Modify Logical Parameter with 9153 OMC-R
C2: Modify Logical Parameter with External Tool.
Options
The following option apply: O1: BSC with an associated MFS
Restrictions
None.
Grouped Task Sequence
The following figure shows the grouped task sequence for this scenario.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
1-3
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Overview
Presentation
....................................................................................................................................................................................................................................
Figure 1-2 Modify Logical Parameters with OMC-R using MLU
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
1-4
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Overview
Presentation
....................................................................................................................................................................................................................................
Preparation
Prerequisites
The following prerequisites apply:
•
•
Before you activate an MLU, you must perform a lock on all BTS-O&M that are in a
faulty state
If an External Tool is used, it must be able to interpret the format of the exported
OMC-R file. The tool's output file must also conform to the same format, so that it
can be imported back into the OMC-R.
For more information, refer to:
– 9153 OMC-R Configuration Import/Export Interface
– 9153 OMC-R-Configuration Import/Export Interface: Supplementary
Information.
The 9159 NPO can interpret and output to this format.
Note: Estimated durations of tasks described in this document are not applicable for
overloaded OMC-Rs.
Site Specific Information
You must have the following information to complete the scenario:
•
•
Site database (location, topography, antenna direction, etc.)
OMC-R user name and password for network reconfiguration
•
•
•
•
Neighborhood relationships (adjacencies)
Border coordination
Coverage plots
Policy on preferred frequency usage.
External Tasks
The following external tasks may apply:
•
•
Running the External Tool program to create the import files, if necessary
Modifying the parameters at the MSC site, if required.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
1-5
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Overview
Scheduling
....................................................................................................................................................................................................................................
Scheduling
Time based on technical constraints
In the following table, the number of resources shown does not take into account
individual customer or safety requirements.
Grouped Task
Site / Resource
Time/Task
Initial Checks
OMC-R /1 ope.
30 min. + 15 min./ BSS+
Create Backup PRC
OMC-R /1 ope.
9 - 42 min.
Export Configuration (C2)
OMC-R /1 ope.
11-29 min.
Import/Synchronize PRC (C2)
MSC /1 ope.
51 min. + 3 min./ BSS -1 h 6 min. + 3
min./ BSS
OMC-R /1 ope.
External Tool Site, if other than
OMC-R / 1 ope.
Modify Parameters (C1)
MSC /1 ope.
OMC-R /1 ope.
Parallel Checks
42 min. + max 22 min./ cell + 3 min./ BSS
- 1 h 19 min. + max 22 min./ cell + 3 min./
BSS
10 min.
Download MLU
OMC-R /1 ope.
22 min. + 12 min./ BSS - 2 h 30 min. +12
min./ BSS
Activate MLU
OMC-R /1 ope.
17 min. + 30 min./ BSS
Final Checks
BTS /1 com
40 min.
OMC-R /1 ope.
Accept MLU
OMC-R /1 ope.
5 min. + 4 min./ BSS
TOTAL TIME
C1: 2 h 55 min. + 1 h 4 min./ BSS + max 22 min./ cell - 6 h 13 min. + 1h 4
min./ BSS + max 22 min./ cell
C2: 3 h 15 min. + 1 h 4 min./ BSS - 6 h 29 min. + 1 h 4 min./ BSS
Notes:
1.
ope. OMC-R operator
2.
Com. Commissioning Team
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
1-6
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Overview
Telecom / Supervision Outage and Operating Impact
....................................................................................................................................................................................................................................
Telecom / Supervision Outage and Operating Impact
Overview
The following table describes the traffic outage and loss of supervision caused by each
grouped task.
Out.
Ref.
Grouped Task
Outage / Impact ...
-
Initial Checks
None.
-
Create Backup PRC
None.
-
Export Configuration
None.
-
Parallel Checks
None.
-
Import/Synchronize PRC
None.
-
Modify Parameters
None.
-
Parallel Checks
None.
-
Download MLU
Supervision Outage
28 min. + 2 min./ BSS - 2h 20min. + 2
min./ BSS
Impact
No network modification is allowed from
now on, either on impacted BSSs or in
cells adjacent to the impacted ones.
Telecom / GPRS
Outage
4 min./ 4 min. (only on impacted cells).
Supervision Outage
17 min. + 10 min./ BSS
Impact
No network modification is allowed from
now on, either on impacted BSSs or in
cells adjacent to the impacted ones.
1
Activate MLU
-
Final Checks
None.
-
Accept MLU
None.
TOTAL TIME
Telecom / GPRS
Outage
4 min./ 4 min. (only on impacted cells)
Supervision Outage
45 min. + 12 min./ BSS - 2h 37 min. + 12
min./ BSS
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
1-7
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Overview
Resources
....................................................................................................................................................................................................................................
Resources
Tools
The following tables describe the tools required for this scenario.
Hardware Tools
Item
Use at ...
Trace mobiles equipped with SIM cards for call testing.
BTS
Software Tools
Item
Use at ...
External Tool
External Tool Site
Customer Documentation CD with the version associated with the current
document edition. Remember that the document you are reading cannot be
used as a paper version. It is online documentation using hypertext links
which take you to other parts of a document on the same CD-ROM. All
words in italics are hypertext links.
OMC-R
Forms
None.
Supplies
Item
Contents
Use at ...
Topology regarding operation.
Must be provided by the
customer.
OMC-R
Applicable Documents
You must have the following documents or have electronic access to the following
documents:
•
Alcatel-Lucent Base Station Subsystem - Methods Handbook
•
Alcatel-Lucent Base Station Subsystem - Configuration Handbook
•
Alcatel-Lucent Base Station Subsystem - Surveillance Handbook
•
•
Alcatel-Lucent Base Station Subsystem - Network Reconfiguration
Recommendations
9153 OMC-R Configuration Import/Export Interface
•
9153 OMC-R Configuration Import/Export Interface: Supplementary Information
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
1-8
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Overview
Resources
....................................................................................................................................................................................................................................
•
•
•
NPO User Guide
NPO Administration Guide
Alcatel-Lucent 9153 Operation & Maintenance Center Radio - Tuning Browser User
Guide.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
1-9
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Overview
Resources
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
1-10
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
2
Scenario
2
Overview
Purpose
This Scenario presents all checks needed before beginning the scenario, and all detailed
tasks to be performed on each site.
Contents
Before Going Onsite
2-3
Preparation Before Going Onsite
2-3
Before You Start
2-4
Preparations Before You Start
2-4
Scenario Description
2-5
Scenario Description Overview
2-5
Initial Checks
2-6
Create Backup PRC
2-8
Modify Parameters
2-10
Export Configuration
2-18
Import / Synchronize PRC
2-20
Download MLU
2-25
Activate MLU
2-29
Final Checks
2-31
Accept MLU
2-32
Reverse Procedure without Accept
2-35
How to Perform Reverse Procedure without Accept
2-35
Reject / Logical Audit / Re-synchronize GPRS
2-36
...................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-1
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Overview
....................................................................................................................................................................................................................................
O1: Activate Backup PRC
2-39
Final Checks
2-41
Reverse Procedure after Accept
2-43
Activate Backup PRC
2-43
Final Checks
2-46
Parallel Checks
2-48
How to Perform Parallel Checks
2-48
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-2
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Before Going Onsite
Preparation Before Going Onsite
....................................................................................................................................................................................................................................
Before Going Onsite
Preparation Before Going Onsite
Overview
Before going onsite, you must check that the following information and supplies are
available:
•
All “Prerequisites” (p. 1-5) are met
•
The customer is informed of the following information.
Indicate the:
– Date and time
•
– Site name and address
– Purpose of operation.
Personnel are available; refer to “Scheduling” (p. 1-6)
•
•
“Site Specific Information” (p. 1-5) is available
•
“Supplies” (p. 1-8) are available and ready for operation
•
“Applicable Documents” (p. 1-8) are available.
“Tools” (p. 1-8) are available and ready for operation
Ensure that the technical release level of the delivered board is in accordance with the
BSS hardware technical release document.
Ensure that the method used at the BSS site is at the same level as at the OMC-R.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-3
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Before You Start
Preparations Before You Start
....................................................................................................................................................................................................................................
Before You Start
Preparations Before You Start
Checks
Perform the following operations:
•
Check that all “Prerequisites” (p. 1-5) are met
•
Check the availability of all necessary “Tools” (p. 1-8) and “Supplies” (p. 1-8)
•
Inform the operator.
Attention: Among the “Cases” (p. 1-3) and the “Options” (p. 1-3), identify which
cases and options apply to you.
Required Knowledge
You must be familiar with the following:
•
Safety Rules and Precautions
•
“Telecom / Supervision Outage and Operating Impact” (p. 1-7)
•
Reverse Procedure
•
“Grouped Task Sequence” (p. 1-3)
•
•
Operating Hints
How to document Faults and Anomalies.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-4
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Scenario Description Overview
....................................................................................................................................................................................................................................
Scenario Description
Scenario Description Overview
Overview
This section describes how to modify logical parameters using a Massive Logical Update
(MLU).
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-5
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Initial Checks
....................................................................................................................................................................................................................................
Initial Checks
Overview
Attention: Before starting the logical parameters modification, stop all
reconfiguration on the network.
Procedure
Perform the following initial checks:
...................................................................................................................................................................................................
1
Check the alignment status of all cells and BSCs and correct them if there are any
discrepancies, using Query Adjacencies Inconsistencies.
If errors are found, Correct Adjacencies Inconsistencies.
Case/Option All
Site OMC-R
Time/Task 20 min.
Outage None.
...................................................................................................................................................................................................
2
View Status of Managed Objects and Alarms on the required BSSs. Print or save this
report as a file. It shows the exact status of the hardware equipment.
Case/Option All
Site OMC-R
Time/Task 10 min.
Outage None.
...................................................................................................................................................................................................
3
Perform BSC/BSS Logical Audit on the BSSs where an MLU is applied. It is advised to
perform this audit on all your BSSs.
Check the global configuration and alignment status of the network in RNUSM.
Case/Option All
Site OMC-R
Time/Task 10 min./ BSS
Outage None.
...................................................................................................................................................................................................
4
Re-synchronize GPRS on the BSC.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-6
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Initial Checks
....................................................................................................................................................................................................................................
Case/Option O1.
Site OMC-R
Time/Task 5 min./ BSS
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-7
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Create Backup PRC
....................................................................................................................................................................................................................................
Create Backup PRC
Overview
Perform this step to create a backup PRC. This allows you to return to the initial
configuration when the “Reverse Procedure without Accept” (p. 2-35) or “Reverse
Procedure after Accept” (p. 2-43) is applied.
Procedure
Create the backup PRC:
...................................................................................................................................................................................................
1
Create a PRC (Backup PRC) in restricted mode. This task opens a PRC by default.
There is one PRC per impacted OMC-R.
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
2
In the Backup PRC, Copy OMC Cells to PRC and Copy External Cells to PRC from the
SC.
Note: The duration depends on the number of cells.
Case/Option All
Site OMC-R
Time/Task 2 - 20 min.
Outage None.
...................................................................................................................................................................................................
3
In the Backup PRC, Check PRC (check all, without forcing the administrative state). If
errors are reported, correct the Backup PRC.
Then, Activate PRC (without forcing the administrative state and without cell cleanup) to
correct the current configuration.
Note: The duration depends on the number of cells.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-8
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Create Backup PRC
....................................................................................................................................................................................................................................
Case/Option All
Site OMC-R
Time/Task 5-20 min.
Outage None.
...................................................................................................................................................................................................
4
Close PRC (Backup PRC).
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-9
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Modify Parameters
....................................................................................................................................................................................................................................
Modify Parameters
Overview
After PRC creation and population, use the tasks in this section to modify the attributes of
one cell. Repeat the following steps for all the cells to be modified.
Procedure
Modify the parameters:
...................................................................................................................................................................................................
1
Create a PRC (Working PRC) in restricted mode. This task opens a PRC by default.
There is one PRC per impacted OMC-R.
Case/Option C1.
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
2
In the Working PRC, Copy OMC Cells to PRC and Copy External Cells to PRC from the
SC.
Note: The duration depends on the number of cells.
Case/Option C1.
Site OMC-R
Time/Task 2-20 min.
Outage None.
...................................................................................................................................................................................................
3
“How to Perform Parallel Checks” (p. 2-48) can be performed now.
Case/Option C1.
Site OMC-R
Time/Task 10 min.
Outage None.
...................................................................................................................................................................................................
4
If necessary, Change Cell LAC / CI for each cell.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-10
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Modify Parameters
....................................................................................................................................................................................................................................
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
5
If necessary, Create Radio Frequency to add a new frequency.
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
6
If you are creating a new FHS definition, add the new frequency and other existing
frequencies, using Create Frequency Hopping System.
If the new frequency is used in an existing FHS definition, add the new frequency and
delete the old frequency, using Modify Frequency Hopping System.
The old frequency must be deleted from the FHS definition before it can be deleted from
the allocated frequency table.
Case/Option C1.
Site OMC-R
Time/Task 2 min./ cell
Outage None.
...................................................................................................................................................................................................
7
If you do not use FHS (no hopping), use Modify TRX to modify the frequencies
(ARFCN).
Note: If you use an existing FHS definition that is used by a TRX (hopping), you do
not need to modify the TRX; it uses the modified FHS definition.
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
8
If necessary, Configure Logical Channels.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-11
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Modify Parameters
....................................................................................................................................................................................................................................
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
9
If necessary, Specify TRX Preference.
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
10
If necessary, Set/Update Circuit/Packet Preference Mark Configuration Using Script.
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
11
If necessary, Configure TRX Channel Hopping Law.
Case/Option C1.
Site OMC-R
Time/Task 2 min./ cell
Outage None.
...................................................................................................................................................................................................
12
Use Delete Radio Frequency to delete the frequency that is no longer used.
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
13
If necessary, Set Cell Telecom Parameters (to change the BCC, NCC, TSC, RAC, PDCH
of the cell).
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-12
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Modify Parameters
....................................................................................................................................................................................................................................
Case/Option C1.
Site OMC-R
Time/Task 3 min./ cell
Outage None.
...................................................................................................................................................................................................
14
If necessary, Create External OMC Cell.
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
15
If necessary, Modify External OMC Cell.
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
16
If necessary, Delete External Cell from SC.
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
17
If necessary, Create Adjacency.
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
18
If necessary, Modify Adjacency.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-13
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Modify Parameters
....................................................................................................................................................................................................................................
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
19
If necessary, Delete Adjacency.
Case/Option C1.
Site OMC-R
Time/Task 1 min./ cell
Outage None.
...................................................................................................................................................................................................
20
Click on Apply & Check in the Edit Cell window to save cell modifications in the
working PRC. If an error occurs, it is reported in the check result window. Information on
how to fix the error is also listed in the check result window.
Click on Close to exit the Edit Cell window.
Case/Option C1.
Site OMC-R
Time/Task 2 min./ cell
Outage None.
...................................................................................................................................................................................................
21
Use the Check All option in Check PRC for MLU to check the parameters, hardware and
telecom impact of your working PRC.
Depending on the parameters you have modified, a window with the impacted items may
appear; you must close this window.
If the check produces error messages, correct the configuration as required and re-attempt
Check PRC for MLU to check the working PRC. Continue corrections and checks until
no errors occur.
Note: The duration depends on the number of cells.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-14
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Modify Parameters
....................................................................................................................................................................................................................................
Case/Option C1.
Site OMC-R
Time/Task 1-20 min.
Outage None.
...................................................................................................................................................................................................
22
Inform the MSC personnel about the new parameters, if necessary.
Case/Option C1 EXCH.
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
23
Stop the automatic DLS backup process with Disable Automatic DLS Backup.
Case/Option C1.
Site OMC-R
Time/Task 1 min./ BSS
Outage None.
...................................................................................................................................................................................................
24
Check if there are still BTS-O&Ms in a faulty state and lock them all, using Lock BTS
O&M Capability.
Case/Option C1.
Site OMC-R
Time/Task 5 min.
Outage None.
...................................................................................................................................................................................................
25
Perform a manual DLS backup for each BSS on the OMC-R side with Backup BSC Data
Base.
Note: Perform this task for all BSS in parallel. Ensure that the DLS backup is finished
before starting any further activity.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-15
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Modify Parameters
....................................................................................................................................................................................................................................
Case/Option C1.
Site OMC-R
Time/Task 10 min.
Outage None.
...................................................................................................................................................................................................
26
Check the unitary report to ensure that there are no DLS inconsistencies.
Perform the following tasks:
•
Open a console window and type the following commands:
cd /alcatel/var/share/DPCK/report
ls
•
Open the unitary report file:
more <BSSNAME>_<Date><Hour><Minute><Second>.log.old
Where
– BSSNAME: the friendly name of the BSC used on the OMC-R
–
Date: 8 bytes, yyyymmdd
–
Hour, Minute, Second: 2 bytes for each, hhmmss
–
•
•
.old: The .old extension is necessary for the OMC-R to perform the log cleanup.
Example: BSS_5_20050729005609.log.old
Check that no errors or warnings are logged here.
Close the unitary report file.
Case/Option C1.
Site OMC-R
Time/Task 10 min.
Outage None.
...................................................................................................................................................................................................
27
Use Lock Alerter to stop the QoS Alerters.
Case/Option C1
Site OMC-R
Time/Task 2 min.
Outage None.
...................................................................................................................................................................................................
28
Check the BSC disks.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-16
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Modify Parameters
....................................................................................................................................................................................................................................
To check the BSC disks:
•
For a 9120 BSC, Display List of Files from a BSC SSD
•
For a 9130 BSC Evolution, Display List of Files from 9130 BSC.
Check if one ELCU file is present:
•
For a 9120 BSC, in the S-CPRA disks
•
For a 9130 BSC Evolution, in the SCPRDISKs.
If an ELCU file is present, make a note of the ELCU file name (the file extension is
incremented each time an MLU is performed).
An ELCU file has the filename ELC_**01.01A.
Case/Option C1.
Site OMC-R
Time/Task 2 min./ BSS
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-17
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Export Configuration
....................................................................................................................................................................................................................................
Export Configuration
Overview
Note: If the 9159 NPO is used:
•
•
The radio configuration is automatically exported every night
To export a fresh configuration, open a terminal as the axadmin user on the
Master OMC-R and type:
/alcatel/omc3/omc3rno/script/run_periodicExport -all
Procedure
Export the configuration:
...................................................................................................................................................................................................
1
Create a PRC (Export PRC) in restricted mode. This task opens a PRC by default.
There is one PRC per impacted OMC-R.
Case/Option C2.
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
2
In Export PRC, Copy OMC Cells to PRC and then Copy External Cells to PRC from the
SC, for impacted BSCs.
Note: The duration depends on the number of cells.
Case/Option C2.
Site OMC-R
Time/Task 2-20 min.
Outage None.
...................................................................................................................................................................................................
3
Perform the “How to Perform Parallel Checks” (p. 2-48).
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-18
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Export Configuration
....................................................................................................................................................................................................................................
Case/Option C2.
Site OMC-R
Time/Task 10 min.
Outage None.
...................................................................................................................................................................................................
4
Export Radio Configuration from the PRC.
Case/Option C2.
Site OMC-R
Time/Task 5 min.
Outage None.
Several files are generated in:
/alcatel/var/share/AFTR/ACIE /ACIE_NLexportDir<y>
Where <y> is the directory number you choose.
...................................................................................................................................................................................................
5
Verify if the export action was successful.
To verify if the export action was successful, open an X terminal window on the OMC-R
and open the directory with the following Unix commands:
cd /alcatel/var/share/AFTR/ACIE /ACIE_NLexportDir<y>
ls -l
Case/Option C2.
Site OMC-R
Time/Task 2 min.
Outage None.
...................................................................................................................................................................................................
6
Close PRC (Export PRC).
Case/Option C2.
Site OMC-R
Time/Task 1 min.
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-19
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Import / Synchronize PRC
....................................................................................................................................................................................................................................
Import / Synchronize PRC
Overview
Do not perform multiple imports of the same cell into the same PRC. Cells must be
imported only once into the PRC.
In order to avoid any discrepancies that could appear between the imported (modified)
configuration and the SC, these files will be imported at a pre-determined time before
applying the MLU session.
Note: To import a fresh OMC-R configuration in NPO, refer to Import Parameter
Values from the NPO Administration Guide.
Procedure
Import or synchronize the PRC:
...................................................................................................................................................................................................
1
Run the External Tool program to create the import files.
If the 9159 NPO is used, refer to Tuning Session Manager from the NPO User Guide and
perform the following steps:
1. Create Tuning Session
2. Check Tuning Session
3. Apply Tuning Session
4. Check if the file generated by tuning session was sent to OMC-R. Select:
Tuning jobs management->Open tuning jobs window->Display tuning job follow
up.
Check in Follow up window if the file was sent to the OMC-R. Perform the following
task only if Step 4 was completed.
Case/Option C2 EXT.
Site External Tool Site
Time/Task Outage None.
...................................................................................................................................................................................................
2
After the External Tool has made its modifications, copy the related files (for 9159 NPO,
files with the extension .csv) to /alcatel/var/share/AFTR/ACIE/ ACIE_NLimportDir<x>,
where <x> is the number of the directory you chose.
Copy the imported files into each OMC-R. Ensure that the directory is not used by
another user, i.e., ensure files do not already exist in the directory. The easiest way is to
choose an empty directory.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-20
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Import / Synchronize PRC
....................................................................................................................................................................................................................................
Note: If the 9159 NPO is chosen, use NPO tuning browser to copy the imported files
into OMC-R. Refer to Using the Tuning Browser in the Tuning Browser User Guide.
Case/Option C2.
Site OMC-R
Time/Task 5 min.
Outage None.
...................................................................................................................................................................................................
3
To verify if the action was successful, open an X terminal window on the OMC-R and
open the directory with the Unix commands:
cd /alcatel/var/share/AFTR/ACIE/ ACIE_NLimportDir<x>
ls -l
Case/Option C2.
Site OMC-R
Time/Task 2 min.
Outage None.
...................................................................................................................................................................................................
4
Create a PRC (Working PRC) in restricted mode.
There is one PRC per impacted OMC-R.
Case/Option C2.
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
5
Import Radio Configuration (ACIE files) into Working PRC.
Case/Option C2.
Site OMC-R
Time/Task 10 min.
Outage None.
...................................................................................................................................................................................................
6
Use the Check All option in Check PRC for MLU to check the parameters, hardware and
telecom impact of your working PRC.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-21
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Import / Synchronize PRC
....................................................................................................................................................................................................................................
Depending on the parameters you have modified, a window with the impacted items may
appear; you must close this window.
If the check produces error messages, correct the errors in the reduced ACIE import files
produced by the external tool and redo the import phase, using a new PRC (Working
PRC+).
Re-attempt Check PRC for MLU on Working PRC+. Repeat this phase until there are no
errors. The correct PRC is used for MLU application.
Note: Each import must be done in a new PRC. Never re-use the same PRC to
re-import the data.
The duration depends on the number of cells.
Case/Option C2.
Site OMC-R
Time/Task 5-20 min.
Outage None.
...................................................................................................................................................................................................
7
Inform the MSC personnel about the new parameters, if necessary.
Case/Option C2 EXCH.
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
8
Stop the automatic DLS backup with Disable Automatic DLS Backup.
Case/Option C2.
Site OMC-R
Time/Task 1 min./ BSS
Outage None.
...................................................................................................................................................................................................
9
Check if there are still BTS-O&Ms in a faulty state and lock them all using Lock BTS
O&M Capability.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-22
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Import / Synchronize PRC
....................................................................................................................................................................................................................................
Case/Option C2.
Site OMC-R
Time/Task 5 min.
Outage None.
...................................................................................................................................................................................................
10
Perform a manual DLS backup for each BSS on the OMC-R side with Backup BSC Data
Base.
Note: Perform this task for all BSS in parallel. Ensure that the DLS backup is finished
before starting any further activity.
Case/Option C2.
Site OMC-R
Time/Task 10 min.
Outage None.
...................................................................................................................................................................................................
11
Check the unitary report to ensure that there are no DLS inconsistencies.
Perform the following tasks:
•
Open a console window and type the following commands:
cd /alcatel/var/share/DPCK/report
ls
•
Open the unitary report file:
more <BSSNAME>_<Date><Hour><Minute><Second>.log.old
Where
– BSSNAME: the friendly name of the BSC used on OMC-R
–
Date: 8 bytes, yyyymmdd
–
Hour, Minute, Second: 2 bytes for each, hhmmss
–
•
•
.old: The .old extension is necessary for OMC-R to perform the log cleanup.
Example: BSS_5_20050729005609.log.old
Check that no errors or warnings are logged here.
Close the unitary report file.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-23
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Import / Synchronize PRC
....................................................................................................................................................................................................................................
Case/Option C2.
Site OMC-R
Time/Task 10 min.
Outage None
...................................................................................................................................................................................................
12
Use Lock Alerter to stop the QoS Alerters.
Case/Option C2
Site OMC-R
Time/Task 2 min.
Outage None.
...................................................................................................................................................................................................
13
Check the BSC disks.
To check the BSC disks:
•
In the case of a 9120 BSC, Display List of Files from a BSC SSD
•
In the case of a 9130 BSC Evolution, Display List of Files from 9130 BSC.
Check if one ELCU file is present:
•
•
In the case of a 9120 BSC, in the S-CPRA disks
In the case of a 9130 BSC Evolution, in the SCPRDISKs.
If an ELCU file is present, make a note of the ELCU file name (the file extension is
incremented each time an MLU is performed).
An ELCU file has the filename ELC_**01.01A.
Case/Option C2.
Site OMC-R
Time/Task 2 min./ BSS
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-24
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Download MLU
....................................................................................................................................................................................................................................
Download MLU
Overview
Attention: No changes can be made once the Apply MLU Session is started from
the PRC.
If there is a doubt about the PRC and you have to close the MLU session on a part of
the BSCs before activating the MLU package, the cells became misaligned on the
concerned BSCs. Perform a rollback and a logical audit on the required BSCs to get
the initial configuration, as described in “Reverse Procedure without Accept”
(p. 2-35).
Also, to recover the initial values in the MFS, it is necessary to activate the Backup
PRC, but only for the required BSCs; refer to “O1: Activate Backup PRC” (p. 2-39)).
Note: When only MFS parameters are modified by applying MLU, a sand-clock
appears only on the GPRS side of the impacted cells (no sand-clock appears on the
GSM side), and the cell aligning status is Aligning Down. In this case, to finish the
modifications, perform only Activate MFS for MLU Package, as described in
“Activate MLU” (p. 2-29).
Procedure
Download the MLU:
...................................................................................................................................................................................................
1
Perform an Audit Alarm State on each BSS.
Case/Option All
Site OMC-R
Time/Task 10 min./ BSC
Outage None.
...................................................................................................................................................................................................
2
Display Cell List Report for all cells from each BSC. Print or save this report as a file. It
shows exactly what is in service before the activation and also which cells are degraded.
Case/Option All
Site OMC-R
Time/Task 5 min.
Outage None.
...................................................................................................................................................................................................
3
Check the PRC for the MLU.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-25
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Download MLU
....................................................................................................................................................................................................................................
Use the Check All option in Check PRC for MLU and click on PRC/SC Diff from the
message window, to help you decide whether the Working PRC must be applied with
synchronization or not.
Note: The duration depends on the number of cells.
Applying the PRC without synchronization will discard all changes made on SC since
the PRC creation.
Case/Option All
Site OMC-R
Time/Task 1-20 min.
Outage None.
...................................................................................................................................................................................................
4
Apply the MLU Session.
From the Working PRC, Apply MLU Session. The MLU can be applied with or without
cells cleanup.
It is recommended to apply the MLU session with cells cleanup because the cells that
were not modified are removed from the PRC and as a result the activation takes less time
and it reduces the risk of overwriting other modifications performed in the network since
the PRC creation time.
Note: This PRC can be applied with cells cleanup only once (when applying it for the
first time).
A result window appears. When the operation is complete, the BSC Current Session
Status flag in the RNUSM Matrix Browser window changes from No Session to MLU
Session and the status of all impacted cells becomes aligning down. Wait until the
Progression Status changes from Idle to In Progress for all BSCs involved in the MLU.
If only MFS parameters are modified, the BSC Current Session Status flag in the
RNUSM window remains No Session.
The Follow up window shows the progress status, expressed in percentages.
Attention: Do not close the working PRC during this operation.
Note: The duration depends on the number of cells.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-26
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Download MLU
....................................................................................................................................................................................................................................
Case/Option All
Site OMC-R
Time/Task 3-30 min.
Outage None.
...................................................................................................................................................................................................
5
Generate the MLU Package.
From the SC, Generate MLU Package for all impacted BSCs.
In the RNUSM Matrix Browser window, select OMC-BSCs. Wait until the Software
Package Production Status changes to Terminated.
Note: A warning appears concerning large PRCs. The duration depends on the PRC
dimension.
Case/Option All
Site OMC-R
Time/Task 3 min.-1h
Outage None.
...................................................................................................................................................................................................
6
Download and preload the MLU Package.
From the SC, Download and Preload MLU Package for all impacted BSCs.
In the RNUSM Matrix Browser window, select OMC-BSCs. Wait until the Replacement
Job Status changes from Downloading to BSC-Preloaded.
If the BSC status remains downloaded, then the preload step failed on the BSC (check
the alarm flow and the X.25/IP status). Once the problem is solved, perform Preload
MLU Package or Abort MLU Package and try again to Download and Preload MLU
Package.
Note: For the 9120 BSC, the duration of this operation depends on the size of
transferred files (15 min. for 1 Mbyte or more on a 64k X.25 link).
There is no restriction on the number of BSCs that you can select for download, but
for supervision purposes it is recommended that you download only four 9120 BSCs
at a time. There is no restriction on the number of 9130 BSC Evolution to be
downloaded at the same time.
If an error message such as
JobUnsuccessful has been received from the BSS: BSC_disk_
problem (13) for the action %s. appears in the Follow up window, connect
to the station of the 9130 BSC Evolution and check, using the df -k command, that
there is enough space on the rootfs partition (less than 95% is in use).
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-27
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Download MLU
....................................................................................................................................................................................................................................
Case/Option All
Site OMC-R
Time/Task 10-35 min.
Outage None.
...................................................................................................................................................................................................
7
End of the operation.
At the end of the operation:
•
For a 9120 BSC, Display List of Files from a BSC SSD
•
For a 9130 BSC Evolution, Display List of Files from a 9130 BSC Evolution.
Check the ELCU file:
•
•
•
•
For a 9120 BSC, in the S-CPRA disks
For a 9130 BSC Evolution, in the SCPR disks.
If an ELCU file existed before the MLU was performed (refer to the last step of
“Modify Parameters” (p. 2-10)), check that the extension of the file was incremented
If no ELCU file was present before the MLU was performed, check that an ELCU file
now exists.
An ELCU file has the filename ELC_**01.01A
The file extension is incremented each time a MLU is performed.
Note: It is recommended to keep a copy of the modified DLS for each impacted BSC.
Case/Option All
Site OMC-R
Time/Task 2 min./ BSC
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-28
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Activate MLU
....................................................................................................................................................................................................................................
Activate MLU
Overview
Attention: There is no restriction on the number of BSCs that you can select for
activation, but for supervision purposes, it is recommended that you activate only four
9120 BSCs at a time. There is no restriction on the number of 9130 BSC Evolution to
be activated at the same time.
Repeat all the tasks below for each group of BSCs.
Procedure
Activate the MLU:
...................................................................................................................................................................................................
1
Activate the MFS for the MLU Package.
From the SC, Activate MFS for MLU Package.
If only MFS parameters were modified and if the MFS does not appear in the displayed
list, it means that the previous task (Apply MLU Session) is not finished yet. Do not
continue the current task until the MFS appears in the list.
Wait until, in the RNUSM Matrix Browser window, in OMC MFSs, the Reservation Status
changes from Busy to Idle.
Note: Perform the next task immediately after the MFS is successfully activated, in
order to limit the time during which the BSC and the MFS are de-synchronized.
Case/Option O1.
Site OMC-R
Time/Task 17 min.
Outage None.
...................................................................................................................................................................................................
2
Activate the MLU Package.
From the SC, Activate MLU Package for all impacted BSCs.
In the RNUSM Matrix Browser window, select OMC-BSCs. Wait for the Replacement Job
Status to become Activated and for the Progression Status to becomeIn Progress for
each impacted BSC. It is not necessary to restart the BSCs.
An alarm / state audit is automatically triggered by the OMC-R when the BSC is
activated. Wait for the end of this action.
Note: The duration of this operation depends on the modification performed in the
reconfiguration.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-29
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Activate MLU
....................................................................................................................................................................................................................................
Case/Option All
Site OMC-R
Time/Task 20 min./ group of 4 9120 BSCs
20 min./ all 9130 BSCs
Outage START1
END1
Refer to “Telecom / Supervision Outage and Operating Impact” (p. 1-7)
...................................................................................................................................................................................................
3
If it was not automatically triggered in the previous task, then perform an Audit Alarm
State on the BSCs.
Compare the results with those obtained before applying the MLU.
Case/Option All
Site OMC-R
Time/Task 10 min./ BSS
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-30
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Final Checks
....................................................................................................................................................................................................................................
Final Checks
Procedure
If the checks are not successful, apply the “Reverse Procedure without Accept” (p. 2-35).
Perform the final checks:
...................................................................................................................................................................................................
1
Perform call and handover tests at the same time as the next check task.
Case/Option All
Site BTS
Time/Task 15 min.
Outage None.
...................................................................................................................................................................................................
2
Display USD Detailed Cell Information.
Check that the cells are in traffic and are operational. If not, see if errors can be corrected
from the OMC-R side; otherwise, reject the MLU Package using the “Reverse Procedure
without Accept” (p. 2-35) .
Display Cell List Report for all cells from each BSC. Print or save this report as a file.
Compare it with the report obtained in the second task of “Download MLU” (p. 2-25)
Perform View Status of Managed Objects and Alarms for the required BSSs. Print or save
this report as a file. Compare it with the report obtained in the second task of “Initial
Checks” (p. 2-6).
Note: If any cell is misaligned, correct the misalignment.
Case/Option CHECK.
Site OMC-R
Time/Task 25 min.
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-31
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Accept MLU
....................................................................................................................................................................................................................................
Accept MLU
Procedure
Accept the MLU:
...................................................................................................................................................................................................
1
Accept the MLU Package.
From the SC, Accept MLU Package for all impacted BSCs.
The Progression Status becomes Finished.
Note: In the RNUSM Matrix Browser window, select OMC-BSCs. Wait for an Idle
Replacement Job Status before closing the session.
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
2
Close the MLU Session.
From the SC, Close MLU Session on the whole MLU session.
TheProgression Status becomesIdle.
Note: If, after applying the close MLU action, a warning appears, then either the
accept of at least one equipment is not completed or the status of one equipment is not
finalized.
If you must return your system to its initial settings later, go to the “Reverse
Procedure after Accept” (p. 2-43). This is only possible if a Backup PRC was created.
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
3
Perform an Audit PM.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-32
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Accept MLU
....................................................................................................................................................................................................................................
Case/Option All
Site OMC-R
Time/Task 3 min./ BSS
Outage None.
...................................................................................................................................................................................................
4
Close PRC (Working PRC).
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
5
Enable the Automatic DLS Backup.
Enable Automatic DLS Backup to restart the automatic DLS backup.
Note: If the time until the next automatic DLS backup is too long, perform a manual
DLS backup, as described in Backup BSC Database.
If a manual DLS backup is performed, the unitary report must be checked as
described in “Modify Parameters” (p. 2-10).
Case/Option All
Site OMC-R
Time/Task 1 min./ BSS
Outage None.
...................................................................................................................................................................................................
6
Unlock Alerter to restart the QoS Alerters.
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
7
Delete PRC (both Working PRC and Backup PRC) when all tasks are completed.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-33
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Scenario Description
Accept MLU
....................................................................................................................................................................................................................................
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-34
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure without Accept
How to Perform Reverse Procedure without Accept
....................................................................................................................................................................................................................................
Reverse Procedure without Accept
How to Perform Reverse Procedure without Accept
Procedure
Note: Depending on the moment when the MLU session was interrupted, to
perform a rollback, start the reverse procedure as indicated below:
•
•
•
After Apply MLU Session or Generate MLU Package, start with Close MLU
Session
After Download and Preload MLU Package, start with Abort MLU Package
After Activate MLU Package, start with Reject MLU Package.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-35
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure without Accept
Reject / Logical Audit / Re-synchronize GPRS
....................................................................................................................................................................................................................................
Reject / Logical Audit / Re-synchronize GPRS
Procedure
Perform the following tasks:
...................................................................................................................................................................................................
1
From the SC, Reject MLU Package on all affected BSCs. Wait until, in the RNUSM
Matrix Browser window, in OMC BSCs, the Replacement Job Status changes to
Downloaded.
Note: An alarm / state audit is automatically triggered by the OMC-R. Wait for the
end of the audit before performing any other action.
Case/Option All
Site OMC-R
Time/Task 10 min.
Outage None.
...................................................................................................................................................................................................
2
From the SC, Abort MLU Package for all affected BSCs. In the RNUSM Matrix Browser
window, the Replacement Job Status must change to Idle.
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
3
From the SC, Close MLU Session on the affected BSCs.
The Progression Status becomes Idle.
Note: Do not close the MLU session for the MFS until the MLU session is closed on
all associated BSCs.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-36
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure without Accept
Reject / Logical Audit / Re-synchronize GPRS
....................................................................................................................................................................................................................................
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
4
For the BSCs that are still present in the MLU session, perform the following actions:
•
“Activate MLU” (p. 2-29)
•
“Final Checks” (p. 2-31)
•
“Accept MLU” (p. 2-32)
Note: When the above operations are finished, continue the procedure for the affected
BSCs.
Case/Option All
Site OMC-R
Time/Task 17 min. + 10 min. /BSS
+ 20 min./ group of 4 9120 BSCs
+ 20 min./ all 9130 BSCs
Outage START1
END1
Refer to “Telecom / Supervision Outage and Operating Impact” (p. 1-7).
...................................................................................................................................................................................................
5
If there are MLU sessions opened, from the SC, Close MLU Session on the whole MLU
session. Acknowledge the confirmation window which appears.
The Progression Status becomes Idle.
Case/Option All
Site OMC-R
Time/Task 1 min./ BSS
Outage None.
Note: If, after applying the close MLU action, a warning appears, then either the
accept of at least one equipment is not completed or the status of one equipment is not
finalized.
...................................................................................................................................................................................................
6
Perform BSC / BSS Logical Audit on each impacted BSS.
Note: The duration of this task depends on the number of impacted cells.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-37
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure without Accept
Reject / Logical Audit / Re-synchronize GPRS
....................................................................................................................................................................................................................................
Case/Option All
Site OMC-R
Time/Task 10 min./ BSS
Outage None.
...................................................................................................................................................................................................
7
Re-synchronize GPRS on the MFS.
Note: If there are still MLU sessions open on other BSS from the required MFS,
perform this action only after these sessions are closed.
Case/Option O1.
Site OMC-R
Time/Task 2 min.
Outage None.
...................................................................................................................................................................................................
8
Close PRC (Working PRC).
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
9
Correct Adjacency Inconsistencies in the Supervised Configuration.
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-38
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure without Accept
O1: Activate Backup PRC
....................................................................................................................................................................................................................................
O1: Activate Backup PRC
Overview
Note: If the MLU session is closed only on a part of the BSCs, you have to create a
new, partial Backup PRC. This PRC, based on the already created backup PRC, must
contain only the impacted cells of the affected BSCs (with neighboring cells).
Activate this partial Backup PRC and close it as described in the following tasks.
Procedure
Activate the backup PRC:
...................................................................................................................................................................................................
1
Open PRC (Backup PRC).
Case/Option O1.
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
2
Remove the BSSs from the backup PRC that are not involved in the reverse procedure.
Case/Option O1.
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
3
Remove all unmapped OMC Cells from PRC (backup PRC)
Case/Option O1.
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
4
Activate the PRC.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-39
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure without Accept
O1: Activate Backup PRC
....................................................................................................................................................................................................................................
Case/Option O1.
Site OMC-R
Time/Task 2 min.
Outage None.
Activate PRC (Backup PRC), with forcing the administrative state, in queued mode
and without cell cleanup.
The Follow up window shows the progress status, expressed in percentages.
Note: Ensure that this PRC is activated in Message Mode.
...................................................................................................................................................................................................
5
Close PRC (Backup PRC).
Case/Option O1.
Site OMC-R
Time/Task 1 min.
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-40
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure without Accept
Final Checks
....................................................................................................................................................................................................................................
Final Checks
Procedure
Perform the following checks:
...................................................................................................................................................................................................
1
Perform call and handover tests.
Case/Option All
Site BTS
Time/Task 5 min.
Outage None.
...................................................................................................................................................................................................
2
Display USD Detailed Cell Information.
Check that the cells are in traffic. If the cells are not in traffic, open the BSSUSM window
Main View for the relevant BTS. Expand the Equipment Tree in the GSM Functional
View panel and ensure that the Administrative State of all objects is Unlocked.
Display Cell List Report for all cells from each BSC. Print this report. Compare this
report with the report obtained in the second task of “Download MLU” (p. 2-25).
Check the alignment status of all cells and the BSCs. Also, Query Adjacency
Inconsistencies.
If errors are found, Correct Adjacency Inconsistencies.
Case/Option All
Site OMC-R
Time/Task 5 min.
Outage None.
...................................................................................................................................................................................................
3
Perform an Audit Alarm State on the BSS. Compare the results with those obtained
before applying the MLU.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-41
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure without Accept
Final Checks
....................................................................................................................................................................................................................................
Case/Option All
Site OMC-R
Time/Task 10 min./ BSS
Outage None.
...................................................................................................................................................................................................
4
Perform an Audit PM.
Case/Option All
Site OMC-R
Time/Task 3 min./ BSS
Outage None.
...................................................................................................................................................................................................
5
Unlock Alerter to restart the QoS Alerters.
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
6
Enable Automatic DLS Backup to restart the automatic DLS backup.
Case/Option All
Site OMC-R
Time/Task 1 min./ BSS
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-42
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure after Accept
Activate Backup PRC
....................................................................................................................................................................................................................................
Reverse Procedure after Accept
Activate Backup PRC
Procedure
Perform the reverse procedure:
...................................................................................................................................................................................................
1
Open PRC (Backup PRC).
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
2
Copy External Cells to the PRC.
If there are newly created external cells, Copy External Cells to PRC (Backup PRC) from
the SC and Delete External Cell from SC (only the newly created external cells).
Note: The duration of the copy operation depends on the number of cells.
Case/Option All
Site OMC-R
Time/Task 4-20 min.
Outage None.
...................................................................................................................................................................................................
3
From the Backup PRC, Apply MLU Session (without cell cleanup).
Note: The duration depends on the number of cells.
Case/Option All
Site OMC-R
Time/Task 3-30 min.
Outage None.
...................................................................................................................................................................................................
4
From the SC, Generate MLU Package.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-43
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure after Accept
Activate Backup PRC
....................................................................................................................................................................................................................................
Note: A warning appears concerning large PRCs. The duration depends on the PRC
dimension.
Case/Option All
Site OMC-R
Time/Task 3 min.-1h
Outage None.
...................................................................................................................................................................................................
5
From the SC, Download and Preload MLU Package.
Note: For the 9120 BSC, the duration of this operation depends on the size of
transferred files (15 min. for 1 Mbyte or more on 64k X.25 link).
Case/Option All
Site OMC-R
Time/Task 10-35 min.
Outage None.
...................................................................................................................................................................................................
6
Activate the MFS for the MLU Package.
From the SC, Activate MFS for MLU Package. Wait until, in the RNUSM Matrix Browser
window, in OMC MFSs, the Reservation Status changes from Busy to Idle.
Note: Perform the next task immediately after the MFS is successfully activated, in
order to limit the time during which the BSC and the MFS are de-synchronized.
Case/Option O1.
Site OMC-R
Time/Task 17 min.
Outage None.
...................................................................................................................................................................................................
7
Activate the MLU Package.
From the SC, Activate MLU Package. Wait until, in the RNUSM Matrix Browser window,
in OMC BSCs, the Replacement Job Status changes to Activated and for the
Progression Status to becomeIn Progress.
An alarm / state audit is automatically triggered by the OMC-R when the BSC is
activated. Wait for the end of this audit.
Note: The duration of this operation depends on the modifications made to the
configuration.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-44
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure after Accept
Activate Backup PRC
....................................................................................................................................................................................................................................
Case/Option All
Site OMC-R
Time/Task 20 min./ group of 4 9120 BSCs
20 min./ all 9130 BSCs
Outage None.
...................................................................................................................................................................................................
8
From the SC, Accept MLU Package. The Progression Status becomesFinished.
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
9
From the SC, Close MLU Session on the whole MLU session. The Progression Status
becomes Idle.
Note: If, after applying the Close MLU action, a warning appears, then either the
accept of at least one equipment is not completed or the status of one equipment is not
finalized.
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
...................................................................................................................................................................................................
10
Close PRC (Backup PRC and Working PRC).
Case/Option All
Site OMC-R
Time/Task 1 min.
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-45
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure after Accept
Final Checks
....................................................................................................................................................................................................................................
Final Checks
Procedure
Perform the final checks:
...................................................................................................................................................................................................
1
Perform call and handover tests.
Case/Option All
Site BTS
Time/Task 5 min.
Outage None.
...................................................................................................................................................................................................
2
Display USD Detailed Cell Information.
Check that the cells are in traffic. If the cells are not in traffic, open the BSSUSM window
Main View for the relevant BTS. Expand the Equipment Tree in the GSM Functional
View panel and ensure that the Administrative State of all objects is Unlocked.
Display Cell List Report for all cells from each BSC. Print this report. Compare this
report with the report obtained in the second task of “Download MLU” (p. 2-25).
Check the alignment status of all cells and the BSCs. Also, Query Adjacency
Inconsistencies. If errors are found, Correct Adjacency Inconsistencies.
Case/Option All
Site OMC-R
Time/Task 5 min.
Outage None.
...................................................................................................................................................................................................
3
Perform an Audit Alarm State on the BSS. Compare the results with those obtained
before applying the MLU.
Case/Option All
Site OMC-R
Time/Task 10 min./ BSS
Outage None.
...................................................................................................................................................................................................
4
Enable Automatic DLS Backup to restart the automatic DLS backup.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-46
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Reverse Procedure after Accept
Final Checks
....................................................................................................................................................................................................................................
Case/Option All
Site OMC-R
Time/Task 1 min./ BSS
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-47
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Parallel Checks
How to Perform Parallel Checks
....................................................................................................................................................................................................................................
Parallel Checks
How to Perform Parallel Checks
Overview
The following checks are also essential, but are not part of the main procedure. Another
operator can perform them in parallel.
Procedure
Perform the parallel checks:
...................................................................................................................................................................................................
1
For the 9120 BSC, check the X.25 links in the Current and Historic Alarm View.
Check if an X.25 Failure is reported.
Case/Option All
Site OMC-R
Time/Task 2 min.
Outage None.
...................................................................................................................................................................................................
2
Check the alarm history on each OMC-R.
Including:
•
Check indeterminate alarms on TCU
•
•
Processor reset / restart
Toggling MO (OML, Abis, A Interface)
•
General alarm flow.
Correct major problems to limit the number of alarms.
Case/Option All
Site OMC-R
Time/Task 5 min.
Outage None.
...................................................................................................................................................................................................
3
Check the BSC disks.
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-48
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
Parallel Checks
How to Perform Parallel Checks
....................................................................................................................................................................................................................................
For a:
•
9120 BSC, Display List of Files from a BSC SSD
•
9130 BSC Evolution, Display List of Files from a 9130 BSC Evolution.
Ensure that only one DLS is present on the two S-CPR disks.
Check the number of free pages and sectors, comparing it with a reference BSC.
Case/Option All
Site OMC-R
Time/Task 3 min.
Outage None.
E...................................................................................................................................................................................................
N D O F S T E P S
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-49
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Scenario
How to Perform Parallel Checks
....................................................................................................................................................................................................................................
....................................................................................................................................................................................................................................
Alcatel-Lucent BSS
2-50
9YZ-03803-1860-RJZZA B12
Issue 2 May 2013
Download