Wire & Cable Single Core Cables Bare Copper Conductors Portable Cord Arc Welding Cables THW Copper Conductor THHN-THWN Copper Conductor TFFN Copper Conductor Romex UF and NMC Copper Conductor Coaxial Cable Instrumentation Cable Saudi Cable Company Ducab Riyadh Cable Jeddah Cable MESC General Cable Alpha Manhattan Carol Triangle Belden Rock Bestos Custom Cable Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES LOW VOLTAGE POWER CABLES Single core, PVC insulated annealed copper conductors (450/750 V) Description Single core cables with copper conductors, PVC insulated, rated 450/750 V conforming to SASO & BS 6004 specification number 55 Construction Conductor Insulation Plain annealed circular copper conforming to IEC:228, class 1 and 2. (Also available in aluminum conductors sizes 10 to 630 mm2). Heat resistive PVC type 5, rated 85°C to 856746 (PVC type 1, 70°C to 856746 also available). To Order Applications Order by catalogue number, quantity and packaging required. Typical applications include equipment wiring, switching and distribution installations in conduits on or under plaster. CJA 1- 10A, 2000 metres in 100 m coils. Example Features Note Example Insulation adheres tightly to conductors yet strips easily, leaves conductor clean PVC insulation has good electrical properties. If 70°C rated PVC insulation is desired, change the second letter to '0' in the catalogue number. The catalogue number for 25 mm2, 70°C rated PVC insulated copper conductor will be CDA1-10W. Single core, PVC insulated annealed copper conductors Rated (450/750 V) Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES MEDIUM VOLTAGE POWER CABLES Armoured cables PVC insulated 0.6/1 kV Description Multi-core cables with copper or aluminium conductors PVC insulated, armoured and PVC sheathed. Cables are rated 0.6/1 kV and conform to IEC:502. Construction Conductor Assembly Plain circular or sector, solid or stranded copper and aluminium conductors, per IEC:228, class 1 and 2. Two, three or tour insulated conductors are laid up, filled with nonhygroscopic material compatible with the insulation and covered with layer of PVC bedding which may be an integral part of the filling Insulation Armour Heat resistive PVC type 5 to BS6746 rated 85DC for continuous operation. (PVC rated 70DC to 856746 also available on request). Galvanized steel tapes or steel wires applied over the P'vC bedding. Sheath PVC type ST2 to IEC 502, colour - black Colours for core identification Application Two core - red and black Three core - red, yellow and blue Four core - red, yellow, blue and black These cables are most suitable for underground burial where there is a risk of mechanical damage. To Order Order by catalogue number, quantity and packaging required. Example FJM4- 1 1A-A01, 8 km, 16 non returnable reels 5OO m each. Armoured cables Copper Conductors PVC insulated 0.6/1 kV DIMENSIONS AND WEIGHTS DST armoured cables Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES Armoured cables Copper Conductors PVC insulated 0.6/1 kV DIMENSIONS AND WEIGHTS DST armoured cables re— Circular Solid Conductor rm— Circular stranded Conductor sm— sector stranded Conductor * Circular conductors can be provided on request Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES Armoured cables Copper Conductors PVC insulated 0.6/1 kV DIMENSIONS AND WEIGHTS RSW armoured cables Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES Unarmoured cables XLPE insulated 0.6/1 kV Description Single core and multi-core cables with copper or aluminium conductors, XLPE insulated, and PVC sheathed. Cables are rated 0.6/1 kV and conform to IEC:502. Construction Conductor Plain circular or sector solid/stranded copper or aluminium conductors, p~r IEC:228, class 1 and 2. Insulation XLPE (Cross-linked polyethylene) insulation, rated 90°C. Assembly Two,three or four insulated conductors are laid up, filled with nonhygroscopic material compatible with the insulation. The filling may be omitted provided the outer shape of the cable remains practically circular and no adhesion occurs between cores and sheath. Sheath Colours for core identification Single core - red ( black on request) Two core - red and black Three core - red, yellow and blue Four core - red, yellow, blue and black PVC type ST2 to IEC 502, colour - black To Order Application Order by catalogue number, quantity and packaging required. These cables have been designated for general use including underground burial, where they are not likely to suffer mechanical damage. Example ENH4-10A, 10km, (10x 1000), non returnable reels Unarmoured cables Copper Conductors XLPE insulated 0.6/1 kV DIMENSIONS AND WEIGHTS Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES Unarmoured cables Copper Conductors XLPE insulated 0.6/1 kV DIMENSIONS AND WEIGHTS Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES Unarmoured cables Copper Conductors XLPE insulated 0.6/1 kV DIMENSIONS AND WEIGHTS 23.8 Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES INSTRUMENTATION & THERMOCOUPLE CABLES INDIVIDUAL AND OVERALL SHIELDED MULTIPAIR/MULTITRIAD OVERALL SHIELDED MULTIPAIR/MULTITRIAD UL STANDARD 13, TYPE PLTC, CSA C22.2 NO. 214, PCC FT4 300 VOLT UL STANDARD 13, TYPE PLTC, CSA C22.2 NO. 214, PCC FT4 300 VOLT CHARACTERISTICS OPERATING TEMPERATURE CHARACTERISTICS SPECIFICATIONS OPERATING TEMPERATURE • • • • • —20OC to 105OC VOLTAGE RATING • 300 Volt PRODUCT DESCRIPTION • Stranded Bare Copper Conductors • PVC Insulation Paired Construction Color Coded – One Black, One White Triad Construction Color Coded – One Black, One White, One Red White Conductor Printed with Pair/ Triad Number at one Inch Intervals for Easy Identification. • When Shielded: Aluminum Polyester Tape and Tinned Copper Drain Wire • PVC Jacket – Black, UV Resistant • —20OC to 105OC UL Standard 13, Type PLTC CSA C22.2 No. 214, PCC FT4 Passes UL Vertical Tray Flame Test Complies with NEC Article 725, Type PLTC • UL Listed, CSA Certified. AVAILABILITY • Bulk, Cut to Length ▲ Available in 1000 ft (305m) put-ups VOLTAGE RATING • 300 Volt PRODUCT DESCRIPTION • Stranded Bare Copper Conductors • PVC Insulation Paired Construction Color Coded – One Black, One White Triad Construction Color Coded – One Black, One White, One Red White Conductor Printed with Pair/ Triad Number at one Inch Intervals for Easy Identification. • When Shielded: Aluminum Polyester Tape and Tinned Copper Drain Wire • PVC Jacket – Black, UV Resistant SPECIFICATIONS • • • • UL Standard 13, Type PLTC CSA C22.2 No. 214, PCC FT4 Passes UL Vertical Tray Flame Test Complies with NEC Article 725, Type PLTC • UL Listed, CSA Certified. AVAILABILITY • Bulk, Cut to Length ▲ Available in 1000 ft (305m) put-ups Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES THERMOCOUPLE WIRE AND CABLE MULTIPAIR OVERALL SHIELDED & INDIVIDUALLY & OVERALL SHIELDED THERMOCOUPLE EXTEN. CABLE UL STANDARD 13, TYPE PLTC 150oC 300 VOLT CHARACTERISTICS OPERATING TEMPERATURE • —20OC to 105OC VOLTAGE RATING • 300 Volt PRODUCT DESCRIPTION • Solid Wire Matched and Calibrated to Standard Limits of Error per ISA Specification RP-1.1-3 and ANSI Circular MC 96.1 • ANSI Color-Coded PVC Insulation and Jacket • Twisted Pairs • Each Conductor Prited with a Pair Number at one Inch Intervals. Numbers are Printed Alternately and Inverted: • When Shielded: Aluminum/Polyster Tape and Tinned Copper Drain Wire Facing In • ANSI Color-Coded PVC Jacket • PVC Jacket – Black, UV Resistant SPECIFICATIONS • • • • • • ISA Specificatin TP-1.1-3 ANSI Circular MC 96.1 Passes UL Vertical Tray Flame Test UL Standard 13, Type PLTC NEC Article 725, Type PLTC UL Listed AVAILABILITY • Bulk, Cut to Length • Items Marked with ▲ Also available in 100 ft. (105m) put-ups UNSHIELDED/OVERALL SHIELDED MULTIPAIR INDIVIDUALLY AND OVERALL SHIELDED MULTIPAIR UL STANDARD 1277, TYPE TC, 90oC 600 VOLT CHARACTERISTICS OPERATING TEMPERATURE • —20OC to 90OC VOLTAGE RATING • 600 Volt PRODUCT DESCRIPTION • Stranded Bare Copper Conductors • PVC/Nylon Insulation Paired Construction Color Coded – One Black, One White White Conductor Printed with Pair/ Number for Easy Identification. • When Shielded: Aluminum Polyester Tape and Tinned Copper Drain Wire • PVC Jacket – Black, UV Resistant SPECIFICATIONS • UL Standard 1277, Type TC • Passes UL Vertical Tray Flame Test • Complies with NEC Article 340 (Article 725 Class 1 † Not Ul Listed • UL Listed AVAILABILITY • Bulk, Cut to Length ▲ Available in 1000 ft (305m) put-ups Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES INSTRUMENTATION & THERMOCOUPLE CABLES INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLES 300 VOLTS (TYPE PLTC) XLPE INSULATED MULTI PAIR/MULTI TRAID INDIVIDUAL & OVERALL SHIELDED Temperature range –40oC to +90oC Specifications: UL13 Application: Can be used in cable tray, conduit or direct burial application for instrumentation / process control, in dry or wet locations. Conductor Tinned copper to ASTM B33 & stranded to class B of ASTM B8. Insulation PAIRS Flame retardant XLPE to ICEA S-66524. Pair Colour Code White and black with pair number on white conductor. Triple Colour Code White, black and red with triple number on white conductor. Pairs/Triplers Twisting All pairs / triples are twisted to counter electromagnetic noise. Individual and Overall Each pair / triple is shielded with Shielding aluminium polyester tape and a tinned copper drain wire, for maximum electrostatic noise and crosstalk rejection. All pair/triple shields are electrically isolated from each other. individually shielded pairs/ triples cabled with nonhygroscopic fillers if necessary and the entire assembly is shielded with aluminium polyester tape and a tinned copper drain wire. Jacket Extruded black PVC as per UL13, oil and sunlight resistant, passes flame test as per IEEE - 383 (70000 BTU). The jacket is impervious to vapour and moisture penetration. Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES INSTRUMENTATION/PROCESS CONTROL CABLES POWER LIMITED TRAY CABLES 300 VOLTS (TYPE PLTC) WIRE ARMOURED XLPE INSULATED MULTI PAIR/TRIAD OVERALL SHIELDED Temperature range –40oC to +90oC Specifications: UL13 Application: Can be used in cable tray, conduit or direct burial application for instrumentation/process control, in dry or wet location. The wire armour provides longitudinal strength for use as a messenger cable or for support in vertical drops (NEC SECTION 300-19) and provides the protection against the mechanical damage. Conductor Tinned copper to ASTM B33 stranded to class B of ASTM B8. & Flame retardant XLPE to ICEA -66-524. S Insulation PAIRS Pair Colour Code White and black with pair number on white conductor. Triple Colour Code White, black and red with triple number on white conductor. Pairs/Triplers Twisting All pairs / triples are twisted to counter electromagnetic noise. Overall Shielding Inner Jacket Wire armour Outer Jacket Twisted Pairs/triples are cabled with non-hygroscopic fillers if necessary and the entire assembly is shielded with aluminum polyester tape and a tinned copper drain wire. Extruded black PVC as per UL13 A serving of round galvanised steel wires is applied with 90% minimum coverage. Extruded black PVC as per UL 13 is oil and sun light resistant and passes flame test as per IEEE-383 (70000 BTU) Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES INSTRUMENTATION & THERMOCOUPLE CABLES BASIC CABLE CONSTRUCTION The aim of cabling fibers is to provide adequate protection during cable installation and service to ensure that transmission properties remain stable throughout the life of the system. The overall design of an optical fiber cable depends upon the environmental conditions in which the cable is to be employed. as well as installation and service conditions. The optical fiber cable is a complicated composite cylindrical structure. In general the cable consists of the following six major components. (1) The loose tube/ tight buffer. made up of polybutylene terephthalate/ thermoplastic elastomer. (2) The central strength member (epoxyl glass rod or steel strands) acts as a strengthening element. and enables the cable to be held under tension at low strain. (3) The peripheral strength member (Aramidi Glass yarns) to supply the principal tensile strength to the cable during installation and to withstand everyday stress experienced by the cable. (4) Steel Armouring. corrugated transversly, is provided for giving lateral strength and bending flexibility to the cable. It makes the cable rodent and termite proof. (5) Filling gel, flooding gel. water blocking tape and moisture barrier tape are provided for protecting the cable from moisture and water. MEFC OPTICAL FIBER CABLES PRODUCT RANGE INDOOR CABLES 1. 2. 3. 4. SIMPLEX CABLE DUPLEX (ZIPCORD) DUPLEX (Round) INDOOR TIGHT BUFFER CABLE. OUTDOOR CABLES 1. 2. 3. 4. 5. DUCT CABLE DIRECT BURIED CABLE ARMOURED CABLE AERIAL (SELF-SUPPORTING) CABLE. HYBRID CABLE. NOTE: Metallic duct & direct buried cables contain aluminium moisture barrier tape. Non-metallic cable consists of dielectric central – strength member & aramid/glass yarns. Armoured cables can be offered with steel wire & corrugated polymer coated steel tape armouring. All dielectric self supporting type & figure 8 type aerial cables are also available. (6) An outer jacket (generally polyethylene) for providing necessary mechanical and environmental protection to the cable. NATURAL PARAMETERS WHICH CAN AFFECT THE OPTICAL FIBER CABLES PARAMETER EFFECT PROTECTION PROVIDED MOISTURE Corrosion, Electric breakdown, Degradation of fiber mechanical strength. LIGHTNING Puncture of cable sheath, Fusing Metallic tapes with good temp. of metallic parts. and electrical conductivity characteristics, or use of all dielectric cable. SUNLIGHT Degradation of Mechanical properties. Colour fading Laminated water block tapes, Metalic moisture barrier tapes, Flooding gel/filling. Use of additives in sheath/ jacket materials. RODENTS BIRDS, INSECTS Sheath Damage. Fiber Break Corrugated steel Tape. Aluminium tape Rainwater Corrosion. Water penetration, Degradation of fiber mechanical strength. Flooding gel & Filling gel. Temperature Thermal contraction/expansion Use of materials with low coefficient of thermal expansion. WINDS Increase in mechanical strain, Abrasive damage due to vibrations. High tensile modulus, Enough margins between operating tensile loads & designed tensile loads. QUALITY ASSURANCE With our highly skilled and qualified workforce and sophisticated machinery, it is ensured that consistently high quality Optical Fiber Cables are delivered to the customers. Continuous quality checks during m a nu f a c t u r in g and comprehensive cable tests guarantee the quality, reliability and performance of the cables during installation and operation. Tests are conducted as per international standards (IEC, ITU - T, EIA/ TIA), and to meet customer specific requirements. After conducting various mechanical and environmental tests the results are evaluated to guarantee the integrity of transmission through optical fibers in the cable. Tensile stresses can occur during cable installation time. These stresses must not affect the functioning of optical fiber. Finished cables are type tested on tensile testing machine to measure fiber strain, " E f' cable strain “Ec" and change in attenuaton as a function of tensile load "F". Optical cables are subject to a wide variety of temperatures (-40" C to +70"C) during operation and storage. These changes should not affect the optical transmission in the fibers. In order to determine the performance of the cable over this wide temperature range, finished cable is put in a computer controlled climatic chamber and change in attenuation is measured by OTDR, as a function of temperature cycles. Beside these tests, all our cables are type tested for Impact resistance, Crush resistance, Torsion and repeated bending. Statistical quality control techniques are implimented to verify the consistency in product quality and continuously monitor the performance of the cable. Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES DUPLEX O.F. CABLE (Tight Buffer) SIMPLEX O.F. CABLE (Tight Buffer) FEATURES • • • • • • Simplex fiber can be either single mode or multi mode. Easier to use as Patch cords. Light, Flexible, Easy Connection and Handling Can be easily installed in Trays, Conduit or Duct. Flame retardant outer sheath. Can with Stand wide range of temperatures and high tensile loads. FEATURES • • • • • • APPLICATION • • • Indoor application. Local area Network Limited outdoor use. APPLICATION • • • TECHNICAL SPECIFICATION Fiber Strength member Out sheath Cable OD Cable weight Minimum bend radius Minimum bend radius Permissible tension Operating Temperature Storage temperature Silica based primary coated fiber Aramid yarn Flame retardant jacketing 3.0 mm 8.0 kg/Km 30mm (no load condition) 45 mm (load condition) Max. 450 Newton -20oC to +70oC -40oC to +70oC Fiber Strength member Out sheath Cable OD Cable weight Minimum bend radius Minimum bend radius Permissible tension Operating Temperature Storage temperature Type of packaging: Plastic reel flange 270mm Standard length: 1000ft. SXL-1 50/125 SXRS-2 62.5/125 ATTENUATION db/km BANDWIDTH MZH-Km 850nm 1300nm 1550nm MAXIMUM 3.5 2.0 n/a TYPICAL 2.6 1.1 n/a MAXIMUM 3.5 1.0 n/a TYPICAL 2.9 0.9 n/a MAXIMUM 5.0 3.0 n/a SXRS-3 100/140 TYPICAL 4.5 2.5 n/a MAXIMUM n/a 0.7 0.7 SXRS-4 SINGLE MODE TYPICAL n/a 0.5 0.5 850nm 1300nm 400 400 160 500 100 n/a 100 n/a Type of packaging: Plastic reel flange 270mm Standard length: 500ft. OPTICAL FIBER SPECIFICATIONS RISER-SIMPLEX PART No. DXRS-1 SXPL-1 SXPL-2 SXPL-3 SXPL-4 SXPL-5 ATTENUATION db/km Fiber Type BANDWIDTH MZH-Km 850nm 1300nm 1550nm 62.5/1.25 50/1225 100/140 SINGLE MODE 62.5/125 MAXIMUM 3.5 1.0 n/a TYPICAL 2.9 0.9 n/a MAXIMUM 3.5 2.0 n/a TYPICAL 2.6 1.1 n/a MAXIMUM 5.5 3.5 n/a TYPICAL 4.5 2.5 n/a MAXIMUM n/a 1.5 1.5 TYPICAL n/a 0.5 MAXIMUM 3.75 1.5 850nm 160 400 ATTENUATION db/km Fiber Type 50/125 MAXIMUM 3.5 2.0 n/a TYPICAL 2.6 1.1 n/a MAXIMUM 3.5 1.5 n/a TYPICAL 2.9 0.9 n/a DXRS-2 62.5/125 MAXIMUM 5.5 3.5 n/a DXRS-3 100/140 TYPICAL 4.5 2.5 n/a SINGLE MODE MAXIMUM n/a 1.5 1.5 DXRS-4 TYPICAL n/a 0.5 0.5 400 850nm 1300nm 400 400 160 500 100 100 n/a n/a OPTICAL FIBER SPECIFICATIONS PLENUM-SIMPLEX 1300nm 500 BANDWIDTH MZH-Km 850nm 1300nm 1550nm OPTICAL FIBER SPECIFICATIONS PLENUM-SIMPLEX PART No. Silica based primary coated fiber Aramid yarn Flame retardant jacketing 3.0 mm x 6.0mm 17 kg/Km 30mm (no load condition) 45 mm (load condition) Max. 685 Newton -20oC to +70oC -40oC to +70oC Packaging Information OPTICAL FIBER SPECIFICATIONS RISER-SIMPLEX Fiber Type Indoor application. Local area Network Limited outdoor use. TECHNICAL SPECIFICATION Packaging Information PART No. Duplex fiber can be either single mode or multi mode. Easier to use as Patch cords. Light, Flexible, Easy Connection and Handling Can be easily installed in Trays, Conduit or Duct. Flame retardant outer sheath. Can with Stand wide range of temperatures and high tensile loads. PART No. DXPL-1 62.5/1.25 100 DXPL-2 50/1225 0.5 n/a n/a DXPL-3 100/140 n/a 160 200 DXPL-5 BANDWIDTH MZH-Km 850nm 1300nm 1550nm 100 DXPL-4 ATTENUATION db/km Fiber Type SINGLE MODE 62.5/125 MAXIMUM 3.5 1.0 n/a 850nm 1300nm 160 500 400 400 100 100 TYPICAL 2.9 0.9 n/a MAXIMUM 3.5 2.0 n/a TYPICAL 2.6 1.1 n/a MAXIMUM 5.5 3.5 n/a TYPICAL 4.5 2.5 n/a MAXIMUM n/a 1.5 1.5 TYPICAL n/a 0.5 0.5 n/a n/a MAXIMUM 3.75 1.5 n/a 160 200 Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES DIRECT BURIED O.F. CABLE INDOOR O.F. CABLE (Tight Buffer) FEATURES • • • • FEATURES • Conforms to MOPTT spec. MAT – 1602. All dielectric design for EMI immunity. Available UL listed type OFNR or OFNP type. Light weight & small ins size (easy installation) • • APPLICATION • • • • Computer network. Local area networks Data Links. APPLICATION DESCRIPTION The tight buffered optical fibers are assembled around the CSM. Which is possess excellent dielectric properties & high resistance to elongation & shrinkage. Aramid yarns serves as peripheral strength member. The outer sheath is made up of flame retardant halogen free copolymer compound. The cable is available up to 12 tight – buffered SM/MM optical fibers. TIGHT BUFFERED OPTICAL FIBER CABLE – INDOOR PRODUCT No. FIBER COUNT The cable allows higher tensile load and larger pulling – in lengths. No stress on fibers during installation, operation & maintenance. The thixotropic jelly prevents axial migration of water. The cable sheaths are specially designed for aggressive environments. OUTER DIA (mm) NET WEIGHT (kg) STANDARD LENGTH (Meter) DRUM SIZE (Flange Dia. mm) • • • • High speed voice, video & data communication. Telemetry and remote control. Local area network. Long haul network (Duct & Direct burial) DESCRIPTION The cable has been designed for outdoor underground (Direct – Burial) application. The PBT loose tubes prevent the optical fibers from axial or radial stresses by allowing free movement of fibers within the tube. Each loose tube (filled with high quality thixotropic gel) contains a maximum of 12 fibers. The cable is well guarded to protect optical & mechanical characteristics of the fibers. The outer jacket has been specially designed to be moisture ultraviolet & fungus resistant. MECHANICAL CHARACTERISTICS Minimum bending radius Minimum bending radius Tensile strength 15 x cable dia. (no load) 20 x Cable dia. (Full load) ≥1KN (others upon request) TBI-004 4 6.8 48 5000 1000 TBI-006 6 6.8 49 5000 1000 TEMPERATURE RANGE TBI-008 8 7.4 55 5000 1000 TBI-010 10 7.8 65 5000 1000 Storage temperature Operating Temperature TBI-012 12 8.4 75 5000 1100 MECHANICAL CHARACTERISTICS Minimum bending radius Minimum bending radius Tensile strength -20oC to +60oC -20oC to +70oC TIGHT BUFFERED OPTICAL FIBER CABLE – INDOOR 15 x cable dia. (no load) 20 x Cable dia. (Full load) ≥500N (others upon request) PRODUCT No. FIBER COUNT No. of LT No. of SM Fibers/LT OUTER DIA (mm) NET WEIGH T (kg) DELIVERY LENGTH (Meter) DRUM SIZE (Flange Dia. mm) DBR – 004 4 2 2 14.80 140.00 5000 1800 DBR – 006 6 3 2 14.80 141.50 5000 1800 DBR – 008 8 4 2 14.80 142.00 5000 1800 DBR – 012 12 6 2 14.80 142.00 5000 1800 DBR – 016 16 4 4 16.30 174.00 4000 1800 DBR – 024 24 6 4 16.30 176.00 4000 1800 DBR – 030 30 5 6 18.00 211.00 3000 1800 DBR – 036 36 6 6 18.00 218.00 3000 1800 DBR – 048 48 8 6 19.55 250.00 2500 1800 DBR – 096 96 8 12 21.00 297.00 2500 1800 TEMPERATURE RANGE Storage temperature Operating Temperature -20oC to +60oC -20oC to +70oC Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES ARMOURED O.F. CABLE HYBRID (FIBER/COPPER) CABLE FEATURES • • • Rodent & Termite proof. Resist Corrosion, mechanical & physical stresses in the cable. Perfect moisture/chemical barrier. FEATURES • • • • APPLICATION • • • Trunk, junction networks and inter exchange links. Oil fields & Railway communications. Long haul networks (under ground). Utilize advantages of bot copper & fiber. Simplified cable installation and reduced costs Increased communication reliability through media diversity. 6/12/24/36 Fibers with a copper pari hybrid cables are available. APPLICATION DESCRIPTION The cable has been designed for underground laying. It is a loose tube construction. The gel filled loose tubes are stranded around FRP Central Strength member and the cable core is flooded with flooding gel. The aramid or glass yarns put over the cable core supplement the tensile strength provided by FRP. Steel tape armouring, corrugated transversely, forms an integral bonded part of the armoured cable. 15 x cable dia. (no load) 20 x Cable dia. (Full load) ≥1.3 x W X 9.8 N (“W“ weight of cable kg/km) TEMPERATURE RANGE -20oC to +60oC -20oC to +70oC Storage temperature Operating Temperature Network requiring media diversity. PTT subscriber loop network. Engineering orderwire communication. As remote power feed for fiber optic links. DESCRIPTION The Hybrid cable shall be tailor made to suit customer requirements. The cables are designed for underground application. Copper conductors (twisted pairs, co-axial cables, power feed conductors etc.) and loose buffer tubes containing optical fibers are assembled around dielectric central strength member. Rest of the cable follows general constructional details for loose tube fiber optic cables. Both halogen –free and standard polyethylene jackets can be provided. MECHANICAL CHARACTERISTICS Minimum bending radius Minimum bending radius Tensile strength • • • • MECHANICAL CHARACTERISTICS Minimum bending radius Minimum bending radius Tensile strength 15 x cable dia. (no load) 20 x Cable dia. (Full load) As per requirement TEMPERATURE RANGE Storage temperature Operating Temperature PRODUCT No. Fiber Count No. of LT No. of SM Fibers/ LT Outer dia mm Net Wt. Kg/Km Delivery Length (mtr) Drum size (flange dia. mm) ARM – 004 4 2 2 17.40 245.00 4000 1800 ARM – 006 6 3 2 17.40 246.00 4000 1800 ARM – 008 8 4 2 18.52 279.00 3000 1800 ARM – 012 12 6 2 18.52 281.00 3000 1800 ARM – 018 18 6 2 or 4 18.52 281.00 3000 1800 ARM – 024 24 6 4 18.52 282.00 3000 1800 ARM – 048 48 6 8 19.72 318.00 3000 1800 -20oC to +60oC -20oC to +70oC Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES FIBER OPTIC CABLES CHARACTERSTICS AND ADVANTAGES OF OPTICAL FIBER CABLES CHARACTERSTICS ADVANTAGES Low attenuation Long repeater spacing or repeaterless networks Wide bandwidth Long transmission Capacity with simultaneous voice, data and video transmission capabilities Immunity from electromagnetic interference No shielding problems, No crosstalk Immunity from NEMP (INCLEAR ELECTROMAGNETIC PULSES) Ideal for high security applications Non-Conductive Transmitter and receiver are electrically isolated Non-inductive No danger of sparks from short circuits, perfect for use in hostile environments Small Size, Small bending Space efficient, ease installation with resulting cost benefits. Utilization of existing duct systems radius and light weight UNDERGROUND DUCT METALLIC SM OPTICAL FIBRE CABLE PRODUCT CODE FEFS TECH. SPEC. NO. 1-Central Strength member 2-Colour coded fiber 3-Colour coded filled loses tubes 4-Filled interstices 5-Wraping tapes 6-Identification Tapes TS - 26000 7-Swelling tapes 8-Glass yarne 9-Aluminum moisture barrier 10-Polyethylene sheath, Black 11-Sheath Marking DESCRIPTION APPLICATION Singlemode optical fiber cables used in telecommunication networks or trunk or inter-exchange routes. The cables are generally hauled into ducts Singlemode fiber, filled colour coded loose tubes, assembled around a central strength member (CSM), filled core , wrapped with dielectric and water blocking tapes, glass yarn strength members, aluminum polymer laminated tape and PE sheath, duct optical fiber cable complying with MOPTT-MAT- 1601 Specifications DUCT METALLIC CABLE SCC Product number Fiber Count Number of loose tubes Number of SM Fibers per tube Approx. Outer Dia. (mm) Approx. Net wt. (kgs/ km) Delivery length (meters) Reel Size (Flange Dia.) (mm) 200001 4 2 2 13.5 153 6,000 1,800 200002 6 3 2 13.5 154 6,000 1,800 200003 8 4 2 13.5 156 6,000 1,800 200004 12 6 2 13.5 156 6,000 1,800 200005 16 4 4 13.5 156 6,000 1,800 200006 24 6 4 13.5 157 6,000 1,800 200007 30 5 6 15 187 6,000 1,900 200008 36 6 6 16 212 6,000 2,000 200009 48 6 8 16 213 6,000 2,000 CHARACTERISITICS OPTICAL MECHANICAL ENVIRONMENTAL Singlemode fiber optimized at 1,310 and/ or 1,550 nm Pulling force (Maximum ) : 2,000 N Bending Radius (minimum) : Full load : 20 *cable diameter No load : 10 *cable diameter Operating Temperature : -30 C° : +70 C° Storage temperature : -20 C° : +70 C° Installation temperature : -10 c° : + 60 C° Other fiber types / specs can be offered upon request Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES UNDERGROUND DUCT NON- METALLIC SM OPTICAL FIBRE CABLE PRODUCT CODE FEFN TECH. SPEC. NO. 1-Central Strength member 2-Colour coded fiber 3-Colour coded filled loses tubes 4-Filled interstices 5-Wraping tapes 6-Identification Tapes TS - 26000 7-Swelling tapes 8-Polyethylene sheath, Black 9-Sheath marking APPLICATION DESCRIPTION Singlemode optical fiber cables used in telecommunication networks or trunk or inter-exchange routes. The cables are generally hauled into ducts Singlemode fiber, filled colour coded loose tubes, MDPE fillers, assembled around a central strength member (CSM), filled core, wrapped with dielectric and water blocking tapes, glass yarn strength members PE sheath, non-metallic OPTICAL FIBRE CABLE for underground duct application complying with MOPTT MAT - 1601 specification. DUCT METALLIC FREE CABLE SCC Product number Fiber Count Number of loose tubes Number of SM Fibers per tube Approx. Outer Dia. (mm) Approx. Net wt. (kgs/ km) Delivery length (meters) Reel Size (Flange Dia.) (mm) 200010 4 2 2 12.0 124 6,000 1,700 200011 6 3 2 12.0 126 6,000 1,700 200012 8 4 2 12.0 126 6,000 1,700 200013 12 6 2 12.0 127 6,000 1,700 200014 16 4 4 12.0 127 6,000 1,700 200015 24 6 4 12.0 127 6,000 1,700 200016 30 5 6 13.6 155 6,000 1,800 200017 36 6 6 14.6 178 6,000 1,900 200018 48 6 8 14.6 179 6,000 1,900 Other fiber count cable—and delivery lengths are available on request CHARACTERISITICS OPTICAL MECHANICAL ENVIRONMENTAL Singlemode fiber optimized at 1,310 and/ or 1,550 nm Pulling force (Maximum ) : 2,000 N Bending Radius (minimum) : Full load : 20 *cable diameter No load : 10 *cable diameter Operating Temperature : -30 C° : +70 C° Storage temperature : -20 C° : +70 C° Installation temperature : -10 c° : + 60 C° Other fiber types / specs can be offered upon request Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES UNDERGROUND DIRECT BURIED METALLIC SM OPTICAL FIBER CABLE PRODUCT CODE FEFSE TECH. SPEC. NO. 1-Central Strength member 2-Colour coded fiber 3-Colour coded filled loses tubes 4-Filled interstices 5-Wraping tapes 6-Identification Tapes 7-Swelling tapes TS - 26000 8-Glass yarne 9-Aluminum moisture barrier 10-Inner Polyethylene sheath 11-Filling Compound 12-Outer polyethylene sheath, Black 13-Sheath Marking, White APPLICATION DESCRIPTION Singlemode optical fiber cables generally used in telecommunication networks or trunk or inter-exchange routes. The cables are used for outdoor direct burial application. Singlemode fiber, filled colour coded loose tubes, MDPE fillers, assembled around a central strength member (CSM), filled core, wrapped with dielectric and water blocking tapes, glass yarn strength members aluminum polymer laminated tape, PE outer and inner sheath, OPTICAL FIBER CABLE for direct burial application complying with MOPTT MAT– 1601 Specifications DUCT BURIED METALLIC CABLE SCC Product number Fiber Count Number of loose tubes Number of SM Fibers per tube Approx. Outer Dia. (mm) Approx. Net wt. (kgs/ km) Delivery length (meters) Reel Size (Flange Dia.) (mm) 200019 4 2 2 15.0 181 6,000 1,900 200020 6 3 2 15.0 181 6,000 1,900 200021 8 4 2 15.0 182 6,000 1,900 200022 12 6 2 15.0 183 6,000 1,900 200023 16 4 4 15.0 183 6,000 1,900 200024 24 6 4 15.0 184 6,000 1,900 200025 30 5 6 16.5 219 6,000 2,000 200026 36 6 6 17.5 247 6,000 2,100 200027 48 6 8 17.5 248 6,000 2,100 Other fiber count cable—and delivery lengths are available on request CHARACTERISITICS OPTICAL MECHANICAL ENVIRONMENTAL Singlemode fiber optimized at 1,310 and/ or 1,550 nm Pulling force (Maximum ) : 1,000 N Bending Radius (minimum) : Full load : 20 *cable diameter No load : 10 *cable diameter Operating Temperature : -30 C° : +70 C° Storage temperature : -20 C° : +70 C° Installation temperature : -10 c° : + 60 C° Other fiber types / specs can be offered upon request Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES UNDERGROUND DIRECT BURIED NON- METALLIC SM OPTICAL FIBER CABLE PRODUCT CODE FEFNE TECH. SPEC. NO. 1-Central Strength member 2-Colour coded fiber 3-Colour coded filled loses tubes 4-Filled interstices 5-Wraping tapes 6-Identification Tapes TS - 26000 7-Swelling tapes 8-Glass yarne 9-Inner Polyethylene sheath 10-Filling Compound 11-Outer polyethylene sheath, Black 12-Sheath Marking, White APPLICATION DESCRIPTION Singlemode optical fiber cables generally used in telecommunication networks or trunk or inter-exchange routes. The cables are used for outdoor direct burial application. Singlemode fiber, filled colour coded loose tubes, MDPE fillers, assembled around a central strength member (CSM), filled core, wrapped with dielectric and water blocking tapes, glass yarn strength members , PE outer and inner sheath, non-metallic OPTICAL FIBER CABLE for direct burial application complying with MOPTT MAT– 1601 Specifications DUCT BURIED METAL FREE CABLE SCC Product number Fiber Count Number of loose tubes Number of SM Fibers per tube Approx. Outer Dia. (mm) Approx. Net wt. (kgs/ km) Delivery length (meters) Reel Size (Flange Dia.) (mm) 200028 4 2 2 14.0 147 6,000 1,800 200029 6 3 2 14.0 148 6,000 1,800 200030 8 4 2 14.0 148 6,000 1,800 200031 12 6 2 14.0 149 6,000 1,800 200032 16 4 4 14.0 149 6,000 1,800 200033 24 6 4 14.0 150 6,000 1,800 200034 30 5 6 15.5 183 6,000 2,000 200035 36 6 6 16.0 210 6,000 2,000 200036 48 6 8 16.0 211 6,000 2,000 Other fiber count cable—and delivery lengths are available on request CHARACTERISITICS OPTICAL MECHANICAL ENVIRONMENTAL Singlemode fiber optimized at 1,310 and/ or 1,550 nm Pulling force (Maximum ) : 1,000 N Bending Radius (minimum) : Full load : 20 *cable diameter No load : 10 *cable diameter Operating Temperature : -30 C° : +70 C° Storage temperature : -20 C° : +70 C° Installation temperature : -10 c° : + 60 C° Other fiber types / specs can be offered upon request Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES UNDERGROUND DIRECT BURIED ARMOURED SM OPTICAL FIBER CABLE PRODUCT CODE FEFSDE TECH. SPEC. NO. 1-Central Strength member 2-Colour coded fiber 3-Colour coded filled loses tubes 4-Filled interstices 5-Wraping tapes 6-Identification Tapes TS - 26000 7-Swelling tapes 8-Glass yarne 9-Inner Polyethylene sheath 10-Corrugated steel tape 11-Outer polyethylene sheath, Black 12-Sheath Marking, White APPLICATION DESCRIPTION Singlemode optical fiber cables generally used in telecommunication networks or trunk or inter-exchange routes. The cables are used for outdoor direct burial application. Singlemode fiber, filled colour coded loose tubes, MDPE fillers, assembled around a central strength member (CSM), filled core, wrapped with dielectric and water blocking tapes, glass yarn strength members , PE inner sheath, Corrugated steel tape and PE outer sheath, OPTICAL FIBER CABLE for direct burial application complying with MOPTT MAT– 1601 Specifications DUCT BURIED ARMOURED CABLE SCC Product number Fiber Count Number of loose tubes Number of SM Fibers per tube Approx. Outer Dia. (mm) Approx. Net wt. (kgs/ km) Delivery length (meters) Reel Size (Flange Dia.) (mm) 200037 4 2 2 16.8 262 6,000 2,000 200038 6 3 2 16.8 263 6,000 2,000 200039 8 4 2 16.8 263 6,000 2,000 200040 12 6 2 16.8 264 6,000 2,000 200041 16 4 4 16.8 264 6,000 2,000 200042 24 6 4 16.8 265 6,000 2,000 200043 30 5 6 18.4 307 6,000 2,200 200044 36 6 6 19.3 336 6,000 2,200 200045 48 6 8 19.3 337 6,000 2,200 Other fiber count cable—and delivery lengths are available on request CHARACTERISITICS OPTICAL MECHANICAL ENVIRONMENTAL Singlemode fiber optimized at 1,310 and/ or 1,550 nm Pulling force (Maximum ) : 1,000 N Bending Radius (minimum) : Full load : 20 *cable diameter No load : 10 *cable diameter Operating Temperature : -30 C° : +70 C° Storage temperature : -20 C° : +70 C° Installation temperature : -10 c° : + 60 C° Other fiber types / specs can be offered upon request Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES ACSR OVERHEAD CONDUCTOR Aluminum conductor steel reinforced (ACSR) Applications ACSR is being universally used for the transmission of electric power over long distances. It is also used as a messenger to support overhead electrical cables. Features Ideal combination of conductivity and strength to permit longest possible spans. Minimum sag between supports with fewer towers required. Description Concentric lay stranded conductors made from round aluminium wires and round zinc-coated steel (*) core wires constructed in accordance with ASTM 8232 (**). Wide variety of sizes available in long lengths to suit both electrical and mechanical design requirements. Good corrosion resistance To order Construction Central core Order by catalogue number, code word, quantity required. A zinc-coated solid steel core wire according to ASTM 8498 or a zinc-coated stranded steel core according to ASTM B500. Example SXX1-A3X code word 'Minorca", 14,000 m. Outer layers Aluminium wires 1350-H19 EC grade to ASTM 8230 concentrically laid up over the central core. * Aluminium-clad steel core wire per ASTM 8502 is also available. ** Also available in accordance with IEC209, 8S215 part 2 and DIN 48204. Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES Aluminum conductor steel reinforced (ACSR) Continued Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES Aluminum clad steel reinforced (ACSR/ AW ) Applications ACSR / AW is being universally used for the transmission of electric power over long distances. It is also used as a messenger to support overhead electrical cables. Features Description Concentric lay stranded conductors made from round aluminum wires and round aluminum-clad steel core wires constructed in accordance with ASTM B549. ACSR I AW incorporates aluminum clad steel wires ( AW wires) combining high tensile strength of steel with high conductivity and high corrosion resistance (nongalvanic corrosion between aluminum wire and core wire). This conductor offers reduced power loss and makes economical overhead transmission system . Construction To order Central core A round aluminum-clad steel core according to ASTM B502. Order by catalogue number, code word, quantity required. Outer layers Example VXX1-P4X code word 'Penguin/ AW 14,000 m Aluminum wires 135O-H19 EC grade to ASTM B230 concentrically laid up over the central core Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES Aluminum clad steel reinforced (ACSR/ AW ) Continued Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES ACSR OVERHEAD CONDUCTOR Aluminum conductor steel reinforced (ACSR) Applications ACSR is being universally used for the transmission of electric power over long distances. It is also used as a messenger to support overhead electrical cables. Features Ideal combination of conductivity and strength to permit longest possible spans. Minimum sag between supports with fewer towers required. Description Concentric lay stranded conductors made from round aluminium wires and round zinc-coated steel (*) core wires constructed in accordance with ASTM 8232 (**). Wide variety of sizes available in long lengths to suit both electrical and mechanical design requirements. Good corrosion resistance To order Construction Central core Order by catalogue number, code word, quantity required. A zinc-coated solid steel core wire according to ASTM 8498 or a zinc-coated stranded steel core according to ASTM B500. Example SXX1-A3X code word 'Minorca", 14,000 m. Outer layers Aluminium wires 1350-H19 EC grade to ASTM 8230 concentrically laid up over the central core. * Aluminium-clad steel core wire per ASTM 8502 is also available. ** Also available in accordance with IEC209, 8S215 part 2 and DIN 48204. Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES Aluminum conductor steel reinforced (ACSR) Continued Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES Aluminum clad steel reinforced (ACSR/ AW ) Applications ACSR / AW is being universally used for the transmission of electric power over long distances. It is also used as a messenger to support overhead electrical cables. Features Description Concentric lay stranded conductors made from round aluminum wires and round aluminum-clad steel core wires constructed in accordance with ASTM B549. ACSR I AW incorporates aluminum clad steel wires ( AW wires) combining high tensile strength of steel with high conductivity and high corrosion resistance (nongalvanic corrosion between aluminum wire and core wire). This conductor offers reduced power loss and makes economical overhead transmission system . Construction To order Central core A round aluminum-clad steel core according to ASTM B502. Order by catalogue number, code word, quantity required. Outer layers Example VXX1-P4X code word 'Penguin/ AW 14,000 m Aluminum wires 135O-H19 EC grade to ASTM B230 concentrically laid up over the central core Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967 أسالك و كابالت WIRES AND CABLES Aluminum clad steel reinforced (ACSR/ AW ) Continued Electrolines Est. P. O. Box. 942 Yanbu Saudi Arabia Tel: +966 4 3225418 Fax: +966 4 3222213 Al-Jubail: Tel: +966 3 3632967 Fax: +966 3 3612967