Part Chapter Section 4 8 3 Vessel Systems and Machinery Electrical Systems Electrical Equipment 4-8-3 TABLE 2 Minimum Degree of Protection (2014) (For high voltage equipment, see 4-8-5/Table 1) Switchboards, Distribution Boards, Motor Control Centers and Controllers Generators Example Condition of of Location Location Motors Transformers, Converters Lighting Fixtures Heating Appliances Accessories (2) Dry accommodation space Danger of touching live parts only IP20 - IP20 IP20 IP20 IP20 IP20 IP20 - IP20 IP20 IP20 IP20 IP20 Danger of dripping liquid and/or moderate mechanical damage IP22 - IP22 IP22 IP22 IP22 IP22 IP22 IP22 IP22 IP22 IP22 IP22 IP44 Steering gear rooms IP22 IP22 IP22 IP22 IP22 IP22 IP44 Refrigerating machinery rooms IP22 IP22 IP22 IP22 IP22 IP44 Emergency machinery rooms IP22 IP22 IP22 IP22 IP22 IP22 IP44 General store rooms IP22 - IP22 IP22 IP22 IP22 IP22 Pantries IP22 - IP22 IP22 IP22 IP22 IP44 Provision rooms IP22 - IP22 IP22 IP22 IP22 IP22 - - - - IP34 IP44 - - IP44 - IP34 IP44 IP55 (3) IP44 - IP44 - IP34 IP44 IP55 (3) IP44 - IP44 - - IP44 IP44 - IP44 IP44 IP34 IP44 IP44 (6) IP55 - IP55 IP55 IP55 IP55 - - - - IP55 IP56 - IP56 - IP55 IP56 IP56 - - - - IPX8 IPX8 Dry control rooms (4) Control rooms Machinery spaces above floor plates (5) Bathrooms and Showers Machinery spaces below floor plates Closed fuel oil or lubricating oil separator rooms Ballast pump rooms Refrigerated rooms Increased danger of liquid and/or mechanical damage Increased danger of liquid and mechanical damage Galleys and Laundries Shaft or pipe tunnels in double bottom Open decks Danger of liquid spray presence of cargo dust, serious mechanical damage, and/or aggressive fumes Exposure to heavy seas Bilge wells Exposure to submersion Holds for general cargo - IP44 IP34 IP44 - IP34 IP44 - - IP55 IP55 IP55 IP56 IP55 Notes: 1 Empty spaces shown with “-” indicate installation of electrical equipment is not recommended. 2 “Accessories” include switches, detectors, junction boxes, etc. 3 Socket outlets are not to be installed in machinery spaces below the floor plate, enclosed fuel and lubricating oil separator rooms or spaces requiring certified safe equipment. 4 For the purpose of this Table, the wheelhouse may be categorized as a “dry control room” and consequently, the installation of IP20 equipment would suffice therein provided that: (a) the equipment is located as to preclude being exposed to steam, or dripping/spraying liquids emanating from pipe flanges, valves, ventilation ducts and outlets, etc., installed in its vicinity, and (b) the equipment is placed to preclude the possibility of being exposed to sea or rain. 5 (2006) See 4-8-3/1.11.2 where the equipment is located within areas protected by local fixed pressure waterspraying or water-mist fire extinguishing system and its adjacent areas. 6 (2014) Socket outlets in galleys and laundries are to maintain their protection against splashed water when not in use. ABS RULES FOR BUILDING AND CLASSING STEEL VESSELS . 2016 717