A320 TECHNICAL TRAINING MANUAL © TRAINING & FLIGHT OPERA TIONS SUPPORT DIVISION AIRBUS INDUSTRIE 28 – FUEL SYSTEM 1- What is the maximum total fuel capacity? A - 41736 LBS (18964 KG) B - 45920 LBS (20866 KG) C - 52174 LBS (23707 KG) 2- Are wing tank pumps running while centre tank is supplying ? A - Yes, wing tank pumps are always running B - No, only when centre tank is empty . C - no, because of center tank pump priority 3- The engine LP valve closes when : A - the fuel booster pumps pressure decreases. B - the engine is shut down or the ENG FIRE pushbutton is released out. C - the engine fire detection system senses an engine fire. 4- When there is a low level in one inner cell : A - one intercell transfer valve opens. B - two transfer valves in one wing , open. C - two transfer valves ,one in each wing ,open 5- What happens if you extend the slats in flight ,with fuel in centre tank , AUTO mode selected ? A - Centre tank pumps start . B - Centre tank pumps stop. C - Centre tank pumps stay as they are. 6- What happens on ground slats extended ,in AUTO MODE with fuel in the centre tank , and one minute after engines start? A - Centre tank pumps are running. B - Centre tank pumps are stopped. C - The wing tank pumps are stopped. 7- What does the MODE SEL pushbutton control ? A - Centre and wing tank pump. B - Centre tank pumps only. C - Wing tank pumps only. 8- When the centre tank is empty , in AUTO MODE , centre tank pumps: A - Must be manually switched OFF. B - Stop automatically and wing tank pumps start running. C - Stop automatically. 9- The inner cell is refueled only when : A - Centre tank is full. B - Outer cell is full. C - Outer cell is empty. A320 TECHNICAL TRAINING MANUAL © TRAINING & FLIGHT OPERA TIONS SUPPORT DIVISION AIRBUS INDUSTRIE 28 – FUEL SYSTEM 10- Refuel valves maybe actuated : A - Electrically only. B - Manually only. C - Electrically or manually 11- An excess pressure in the inner cell is relieved via an overpressure protector : A - Into the outer cell B - Into the Centre tank. C - Overboard. 12-The Vent Float Valves : A - Prevent fuel from entering the vent lines. B - Allow fuel to drain from the vent lines. C - Maintain the fuel tanks pressurized. 13- When does the FADEC close the fuel return valve? A - If the IDG oil is too hot. B - If there is a signal from the FLSCUs. C - If there is no signal from the FLSCUs. 14- What happens if one channel of the FQIC fails ? A - Half of the Quantity Indicating data is no longer available. B - FQIS operates normally , only CFDSN report will indicate failure . C -Fuel warning is triggered in addition to CFDS report. 15- What happens if a quantity probe (other than 13 or 14) fails ? A - Corresponding tank qty display flashes . B - Quantity indication disappears. C - Quantity indication remains the same. 16- What happens when a low level is detected in the Inner cell ? A - Automatically ,Transfer valves open to admit fuel to inner cell. B - Automatically ,Transfer valves close to isolate the inner cell. C - Restart of the pumps to suck fuel from the Outer cell. 17- What is the purpose of the IDG SHUT-OFF sensor ? A - To stop the Centre Tank Pumps. B - To restart cooling fuel recirculation. C - To stop the cooling fuel recirculation. 18- In which cells are level sensors fitted ? A - Inner and Outer cells. B - Inner cells only. C - Outer cells only. 19- What happens if a high level is detected ? A - A warning is triggered : too much fuel. B - All the refueling operations are stopped . C - The corresponding REFUEL Valve closes.