Batch Reactor Experiment * value of conductivity at the beginning of the experiment represents 0% conversion, while that at the end of the experiment represents 100% conversion. 1. EtAc excess: 700 mL of 0.05 M EtAc and 70 mL of 0.05 M NaOH Time (min) 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 6.5 7 7.5 8 8.5 9 9.5 10 2. Conductivity (uS) 1060 926 839 783 726 673 628 592 563 538 515 498 480 468 457 446 439 428 423 420 418 NaOH excess: 700 mL of 0.05 M NaOH and 70 mL of 0.05 M EtAc Time (min) 0 0.5 1 1.5 2 2.5 3 3.5 4 4.5 5 5.5 6 Conductivity (mS) 10.18 9.95 9.89 9.76 9.69 9.58 9.5 9.47 9.4 9.37 9.3 9.29 9.25 6.5 7 7.5 8 8.5 9 9.5 10 10.5 9.21 9.22 9.19 9.16 9.14 9.11 9.12 9.09 9.09 CSTR Reactor Experiment 1. concentration of NaOH and EtAc in the storage tank in CSTR reactor is 0.05 M (CNaOH,storage = CEtAc,storage = 0.05 M) 2. calibration of conductivity probe 3. 1.1 0.025 M sodium hydroxide (represent XNaOH = 0%): 5.5 mS 1.2 0.025 M sodium acetate (represent XNaOH = 100%): 1.72 mS 1.3 0.0125 M sodium hydroxide and 0.0125 M sodium acetate (represents XNaOH = 50%): 3.66 mS Flow rate for pumps 3.1 FNaOH = 46.2 mL/min 3.2 FEtAc = 42.6 mL/min 4. volume of reaction mixture (V) = 1620 mL 5. Data Test 1 2 Temperature Conductivity (°C) (mS) 30.7 3.71 35.4 3.63