Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Quick Reference Hydraulic Vent Model No. CP448-1 CB10-HV Description Counterbalance Valve, Hydraulic Vent, SDC10-3S Pilot Port 3 CP441-1 CP12-3S CB20-HV CP20-3S Model No. CB10-AV Cavity Description SDC10-3S Counterbalance Valve, Atmospheric Vent, Pilot Port 3 Flow* 60 l/min [16 US gal/min] Pressure 350 bar [5075 psi] Page CB - 14 Model No. VCB06-CN Cavity NCS06/3 Flow* 60 l/min [16 US gal/min] Pressure 350 bar [5075 psi] Page CB - 16 VCB12-CN NCS12/3 Description Counterbalance Valve, Atmospheric Vent, Pilot Port 1 140 l/min [37 US gal/min] 350 bar [5075 psi] CB - 18 Model No. VCB06-EN Cavity NCS06/3 Description Counterbalance Valve, Hydraulic Vent, Pilot Port 1 NCS12/3 Pressure 350 bar [5075 psi] 350 bar [5075 psi] Page CB - 20 VCB12-EN Flow* 60 l/min [16 US gal/min] 140 l/min [37 US gal/min] Model No. CP448-2 Cavity CIB Pressure 350 bar [5075 psi] Page CB - 24 VCB06-EN-DL CIB Flow* 20 l/min [5 US gal/min] 60 l/min 350 bar [5075 psi] CB - 26 [16 gal/min] 60 l/min [16 US gal/min] 115 l/min [30 US gal/min] 140 l/min [37 US gal/min] 266 l/min [70 US gal/min] 350 bar [5075 psi] 350 bar [5075 psi] 350 bar [5075 psi] 345 bar [5000 psi] CB - 28 Flow* 60 l/min [16 US gal/min] 60 l/min [16 US gal/min] 140 l/min [37 US gal/min] Pressure 350 bar [5075 psi] 350 bar [5075 psi] 350 bar [5075 psi] 1 3 2 Atmospheric Vent 1 ATM. Cavity CP08-3L Flow* 20 l/min [5 US gal/min] 60 l/min [16 US gal/min] 115 l/min [30 US gal/min] 266 l/min [70 US gal/min ] Pressure 350 bar [5075 psi] 350 bar [5075 psi] 350 bar [5075 psi] 345 bar [5000 psi] Page CB - 6 CB - 8 CB - 10 CB - 12 3 2 Atmospheric Vent CB - Counterbalance Valves Quick Reference Hydraulic Vent Dual Counterbalance C1 C2 V1 V2 Dual Counterbalance C1 C2 ATM. ATM. V1 V2 DCB10-HV CIB CP441-2 CIB VCB12-EN-DL CIB DCB20-HV CIB Model No. VCB06-CN-DL Cavity CIB DCB10-AV CIB VCB12-CN-DL CIB Description Dual Counterbalance Valve, Hydraulic Vent, Catalog HIC Description Dual Counterbalance Valve, Atmospheric Vent, Catalog HIC, Nose to Nose CB - 22 CB - 30 CB - 32 CB - 34 Page CB - 36 CB - 38 CB - 40 * Flow ratings are based on a pressure drop of 22 bar [319 psi] unless otherwise noted. They are for comparison purposes only. CB - 2 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Application Notes Hydraulic Vent C1 V1 C2 T Model No. DCB10-MC Cavity CIB DCB12-MC CIB Description Flow* Dual Counterbalance Valve, 57 l/min With Makeup Checks, [15 US gal/min] Catalog HIC 350 bar [5075 psi] 95 l/min [25 US gal/min] 350 bar [5075 psi] Page CB - 42 CB - 44 V2 MOTION CONTROL VALVES Motion control valves, also referred to as load holding valves, are used to control the motion of a load in the following ways: Prevent a load from dropping in case of hose or tube failure. Prevent a load from drifting caused by directional control valve spool leakage. Provide smooth, modulated motion when the load is in a lowering or run-away mode. Provide smooth, modulated motion when the directional control valve is suddenly closed. There are two basic types of motion control valves: · Pilot-operated, or pilot-to-open check valves will satisfy the first two of the above requirements. Counterbalance valves will satisfy all four of the above requirements. · Counterbalance valves COUNTERBALANCE VALVES A counterbalance valve provides several functions: · · · · · · 11141716 • Rev CA • August 2015 Free flow in one direction. Leak-free load holding. Protection against hydraulic line failure. Protection against pressure shocks caused by external forces or overrunning loads Cavitation-free motion control to match speed to pump flow when a load could cause loss of control of an actuator (cylinder or motor). Smooth, modulated motion control when the directional valve is suddenly closed. CB - 3 CB - Counterbalance Valves Application Notes · · · · Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Application Notes COUNTERBALANCE VALVES (continued) Counterbalance valves will positively hold a pressurized load and will control the motion of the load based on application of a pressure signal to the pilot port. Counterbalance valves are available as individual cartridges or standard cartridge-in-body (CIB) packages. CB - Counterbalance Valves Application Notes A typical circuit application for a counterbalance valve contains a pump, directional control valve, and an actuator. Without a counterbalance valve the load will drift down due to spool leakage if the directional control valve is centered with the load raised. Additionally there is no protection against the load dropping in the event of hydraulic line failure. Individual cartridge counterbalance valve 1 2 3 P103 055 Circuit without a counterbalance valve W P103 121 Adding a counterbalance valve controls motion and provides protection against hose or tube failure. In this circuit, moving the directional control valve to the left causes the cylinder to extend, raising the load with free flow going through the check valve portion of the counterbalance valve. When the directional control valve is centered, the counterbalance valve will prevent leakage and lock the load in position. Moving the directional control valve to the right sends flow/pressure to the rod end of the cylinder. This pressure also acts to pilot open the counterbalance valve and allows the load to be lowered. Should the load cause the cylinder to run away from the pump, pilot pressure to the counterbalance valve will decrease and the counterbalance valve will modulate to match the cylinder speed to the pump flow. CB - 4 Circuit with a counterbalance valve W P103 122 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Application Notes COUNTERBALANCE VALVES (continued) The pressure required to pilot open the counterbalance valve can be calculated as follows: P = (Ps • Ab) - W (load retracts cylinder) (Ab • R) + Ar P = (Ps • Ar) - W (load extends cylinder) (Ar • R) + Ab W Ps Ab Ar R = Load = Counterbalance valve relief setting; see below for more information = Cylinder bore area = Cylinder bore area-Cylinder rod area = Counterbalance valve pilot ratio; see below for more information Note that these equations are idealized and do not consider any backpressure in the circuit, which is additive to the pressure required to pilot open the check valve. · Specify the counterbalance valve relief setting high enough to stop any motion (flow) at the maximum expected actuator pressure. Generally it is recommended to use a setting of 1.3 multiplied by the maximum load pressure. · Use low pilot ratios (3:1 and 4.5:1) for applications where loads may vary widely. Low pilot ratios require higher pilot pressure and are less efficient but provide stable, precise control for varying loads. · Use high pilot ratios (8:1 and 10:1) for applications where loads are relatively constant. High pilot ratio valves require lower pilot pressure, have faster response, and are more efficient, but lack stability and precision in response to varying loads. · Do not oversize counterbalance valves. There is no pressure drop operating limit for counterbalance valves and in fact some pressure drop is required to maintain valve operation. · Locate counterbalance valves at or near the actuator to provide maximum load holding protection in the event of hydraulic line failure. · Do not use counterbalance valves with closed-center directional control valves. Pressure trapped between the directional control valve and the actuator can pilot the counterbalance valve open and result in undesired load motion. · Do not use counterbalance valves with tandem-center directional control valves. Backpressure in the system can prevent the counterbalance valve from opening. Do 11141716 • Rev CA • August 2015 Do not Do not CB - 5 CB - Counterbalance Valves Application Notes Some additional guidelines for counterbalance valve applications: Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent CP448-1 OPERATION This 3-ported, externally piloted counterbalance valve is 8-size, cartridge style, low leakage with hydraulic vent. The check section allows free flow from the directional valve (port 2) to the load (port 1), while normally blocking flow from port 1 to port 2. Reverse flow is blocked until pilot pressure is applied at port 3. When the load pressure at port 1 rises above the pressure setting, the relief valve is activated and pressure is relieved from port 1 to port 2. APPLICATIONS SPECIFICATIONS Rated pressure Rated flow at 22 bar (319 psi) Leakage SCHEMATIC 350 bar [5075 psi]* 20 l/min [5 US gal/min] 1 10 drops/min @ 70% of crack pressure Weight 0.16 kg [0.36 lb] Pilot ratio 3:1, 4.5:1, 8:1 Cavity CP08-3L * 350 bar with steel housing 210 bar with aluminum housing 3 2 PERFORMANCE psi 435 bar 30 363 25 290 20 218 145 73 Pressure drop CB - Counterbalance Valves CP448-1 Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed close to or in an actuator. Dual valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center. 154 SUS (33 cSt) hyd. oil @ 100° F (38° C) piloted open 1 free flow 2 1 8.0:1 2 4.5:1 15 3.0:1 10 5 0 L/min 4 8 12 16 20 3.2 4.2 5.3 Flow US gal/min CB - 6 1.1 2.1 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent CP448-1 DIMENSIONS mm [in] h 0.875 in t 34-41 N.m [25-30 lbf.ft] 3/4-16 UNF turn ccw to increase pressure setting turn cw to reduce pressure setting 1 2 45.7 [1.80] 3 3/16 in 52.1 max. [2.05] Load Holding Single Actuator Load Holding Double Actuator CP448-1 CP448-1 CP448-1 ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 7 CB - Counterbalance Valves CP448-1 EXAMPLE CIRCUITS Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent CB10-HV OPERATION CB10-HV : Counterbalance valve, 10-size, hydraulic vent. This valve is 3-ported, externally piloted and low leakage. The check section allows free flow from the directional valve (port 2) to the load (port 1), while normally blocking flow from port 1 to port 2. Reverse flow is blocked until pilot pressure is applied at port 3. When the load pressure at port 1 rises above the pressure setting, the intergral relief valve is activated and pressure is relieved from port 1 to port 2. APPLICATIONS Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center. CB - Counterbalance Valves CB10-HV SPECIFICATIONS Rated pressure Rated flow at 22 bar (319 psi Leakage SCHEMATIC 350 bar [5075 psi]* 60 l/min [16 US gal/min] 1 10 drops/min @ 70% of crack pressure Weight 0.22 kg [0.47 lb] Pilot ratio 3:1, 4.5:1, 10:1 Cavity SDC10-3S * 350 bar with steel housing 210 bar with aluminum housing 3 2 PERFORMANCE psi bar 25 300 26 cSt [121 SUS] hyd.oil at 50°C [122°F] Pilot open 20 200 15 Free flow 10 100 5 0 10 3 CB - 8 20 6 30 40 9 50 12 60 l/min 15 US gal/min 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent CB10-HV DIMENSIONS mm [in] 7/8-14 UNF-2A 27mm 45 - 50 Nm [33-37 lbf*ft] 3 1 Type E: External Adjustment Type F: Tamper Resistant 4mm Turn ccw to increase pressure setting Turn cw to reduce pressure setting Ø21.2 [Ø0.83] 17mm 16 - 20 Nm [12-15 lbf*ft] 2 4 [0.16] 46.3 [1.82] 36.4 [1.43] Load Holding Single Actuator CounterbalanceDouble Actuator CB10-HV CB10-HV CB10-HV ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 9 CB - Counterbalance Valves CB10-HV EXAMPLE CIRCUITS Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent CP441-1 OPERATION This 3-ported, externally piloted unit is a 12-size cartridge style, low leakage counterbalance valve with hydraulic vent. The check section allows free flow from the directional valve (port 2) to the load (port 1), while normally blocking flow from port 1 to port 2. Reverse flow is blocked until pilot pressure is applied at port 3. When the load pressure at port 1 rises above the pressure setting, the integral relief valve is activated and pressure is relieved from port 1 to port 2. APPLICATIONS Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center. Rated pressure Rated flow at 22 bar (319 psi ) Leakage SCHEMATIC 350 bar [5075 psi]* 115 l/min [30 US gal/min] 1 10 drops/min @ 70% of crack pressure Weight 0.22 kg [0.48 lb] Pilot ratio 3:1, 4.5:1, 10:1 Cavity CP12-3S * 350 bar with steel housing 210 bar with aluminum housing 3 2 PERFORMANCE psi 435 bar 30 363 25 290 20 218 145 73 Pressure drop CB - Counterbalance Valves CP441-1 SPECIFICATIONS 154 SUS (33 cSt) hyd. oil @ 100° F (38° C) pilot open 15 free flow 10 5 0 L/min 40 80 120 160 200 31.7 42.3 52.8 Flow US gal/min 10.6 CB - 10 21.1 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent CP441-1 DIMENSIONS mm [in] 1-1/16-12 UN h 1.25 in t 68-75 N.m [50-55 lbf.ft] turn ccw to increase pressure setting turn cw to reduce pressure setting 1 4mm 2 3 55.9 [2.20] 41.1 [1.62] Load Holding Single Actuator CounterbalanceDouble Actuator CP441-1 CP441-1 CP441-1 ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 11 CB - Counterbalance Valves CP441-1 EXAMPLE CIRCUITS Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent CB20-HV OPERATION CB20-HV : Counterbalance valve, 20-size, hydraulic vent. This is a 3-ported, externally piloted, cartridge style, low leakage unit. The check section allows free flow from the directional valve (port 2) to the load (port 1), while normally blocking flow from port 1 to port 2. Reverse flow is blocked until pilot pressure is applied at port 3. When the load pressure at port 1 rises above the pressure setting, the integral relief valve is activated and pressure is relieved from port 1 to port 2. APPLICATIONS CB - Counterbalance Valves CB20-HV Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center. SPECIFICATIONS Rated pressure Rated flow at 22 bar (319 psi ) Leakage SCHEMATIC 345 bar [5000 psi]* 266 l/min [70 US gal/min] 1 10 drops/min @ 70% of crack pressure Weight 1.22 kg [2.69 lb] Pilot ratio 3:1, 4.5:1, 10:1 Cavity CP20-3SP20-3S * 345 bar with steel housing 210 bar with aluminum housing 3 2 PERFORMANCE CB - 12 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent CB20-HV DIMENSIONS EXAMPLE CIRCUITS Load Holding Double Actuator Load Holding Single Actuator CB20-HV CB20-HV CB20-HV ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 13 CB - Counterbalance Valves CB20-HV mm [in] Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Atmospheric Vent CB10-AV OPERATION CB10-AV : Counterbalance valve, 10-size, atmospheric vent. This is a 3ported, externally piloted, cartridge style, low leakage unit. The check section allows free flow from the directional valve (port 2) to the load (port 1). Reverse flow is blocked until pilot pressure is applied at port 3. When the pressure at port 1 rises above the pressure setting, the integral relief valve is activated and vents the area behind the pilot piston. APPLICATIONS Atmospheric vented valves are applied when it is not practical to connect a separate vent line to the tank. Use a single counterbalance valves when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual valves can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center. CB - Counterbalance Valves CB10-AV SPECIFICATIONS SCHEMATIC Rated pressure 350 bar [5075 psi]* Rated flow at 22 bar (319 psi ) Leakage 60 l/min [16 US gal/min] 1 ATM. 10 drops/min @ 70% of crack pressure Weight 0.27 kg [0.60 lb] Pilot ratio 3:1, 4.5:1, 10:1 Cavity SDC10-3S * 350 bar with steel housing 210 bar with aluminum housing 3 2 PERFORMANCE psi bar 25 300 20 200 15 26 cSt [121 SUS] hyd.oil at 50°C [122°F] Pilot open Free flow 10 100 5 0 10 3 CB - 14 20 6 30 40 9 50 12 60 l/min 15 US gal/min 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Atmospheric Vent CB10-AV DIMENSIONS mm [in] 7/8-14 UNF-2A 27mm 45 - 50 Nm [33-37 lbf*ft] 3 17mm 16 - 20 Nm [12-15 lbf*ft] Type E: External Adjustment 1 Type F: Tamper Resistant 4mm Turn ccw to increase pressure setting Turn cw to reduce pressure setting 61 [2.4] Ø26.5 [Ø1.04] 2 11.6 [0.46] 46.3 [1.82] Counterbalance Double Actuator Load Holding Single Actuator CB10-AV CB10-AV CB10-AV ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 15 CB - Counterbalance Valves CB10-AV EXAMPLE CIRCUITS Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Atmospheric Vent VCB06-CN OPERATION This counterbalance valve is a 6-size metric, 3-ported, externally piloted low leakage, cartridge style valve with atmospheric vent. The check section allows free flow from the directional valve (port 2) to the load (port 3), while normally blocking flow from port 3 to port 2. Reverse flow is blocked until pilot pressure is applied at port 1. When the pressure at port 3 rises above the pressure setting, the integral relief valve is activated and vents the area behind the pilot piston. APPLICATIONS CB - Counterbalance Valves VCB06-CN Atmospheric vented valves are applied when it is not practical to connect a separate vent line to the tank. Use a single counterbalance valve when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they are suitable as hose-break valves when installed near or within an actuator. Dual cartridges can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center. Since this valve is piloted at port 1, no cross port drilling is required when dual cartridges are mounted nose to nose in an HIC. SCHEMATIC SPECIFICATIONS Rated pressure Rated flow at 22 bar (319 psi ) Leakage 350 bar [5075 psi]* 60 l/min [16 US gal/min] 10 drops/min @ at 70% of crack pressure Weight 0.29 kg [0.65 lb] Pilot ratio 4.1:1, 7.1:1 Cavity NCS06/3 * 350 bar with steel housing 210 bar with aluminum housing PERFORMANCE CB - 16 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Atmospheric Vent VCB06-CN DIMENSIONS mm [in] turn cw to increase pressure setting turn ccw to decrease pressure setting Load Holding Single Actuator Counterbalance with Pressure Limiting VCB06-CN VCB06-CN VCB06-CN ORDERINGINFORMATION 11141716 • Rev CA • August 2015 CB - 17 CB - Counterbalance Valves VCB06-CN EXAMPLE CIRCUITS Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Atmospheric Vent VCB12-CN OPERATION This counterbalance valve is a 12 size metric, 3-ported, externally piloted low leakage, cartridge style valve with atmospheric vent. The check section allows free flow from the directional valve (port 2) to the load (port 3), while normally blocking flow from port 3 to port 2. Reverse flow is blocked until pilot pressure is applied at port 1. When the pressure at port 3 rises above the pressure setting, the integral relief valve is activated and vents the area behind the pilot piston. APPLICATIONS CB - Counterbalance Valves VCB12-CN Atmospheric vented valves are applied when it is not practical to connect a separate vent line to the tank. Use a single counterbalance valve when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they are suitable for use as hose-break valves when installed near or within an actuator. Dual cartridges can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center. Since this valve is piloted at port 1, no cross port drilling is required when dual cartridges are mounted nose to nose in an HIC. SCHEMATIC SPECIFICATIONS Rated pressure 350 bar [5075 psi]* Rated flow at 22 bar (319 psi ) Weight Pilot ratio 140 l/min [37 US gal/min] 0.93 kg [2.05 lb] 4.7:1, 5.9:1, 6.9:1 Cavity NCS12/3 * 350 bar with steel housing 210 bar with aluminum housing PERFORMANCE psi bar 20 Pressure drop 26 cSt [125 SUS] hyd.oil @ 20° C[68°F] 250 3 2 15 200 150 10 100 5 2 50 0 0 l/min US gal/min CB - 18 35 10 70 3 140 105 20 30 11141716 • Rev CA • August 2015 Quick Reference Table of Contents/Introduction Index Counterbalance Valves Catalog Atmospheric Vent VCB12-CN DIMENSIONS mm [in] 38mm 65-70 Nm [47-52 lbf*ft] M 33x2 1 turn cw to increase pressure setting turn ccw to decrease pressure setting 17mm 13-17 Nm [9-12 lbf*ft] 3 16 [0.63] 128Max Ø37.5 [Ø1.48] 10mm 2 66 [2.6] Load Holding Double Actuator Load Holding Single Actuator VCB12-CN VCB12-CN VCB12-CN ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 19 CB - Counterbalance Valves VCB12-CN EXAMPLE CIRCUITS Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent VCB06-EN OPERATION The VCB06-EN is a cartridge style, 6-size metric counterbalance valve with hydraulic vent. This valve is 3ported, externally piloted and low leakage. The check section allows free flow from the directional valve (port 2) to the load (port 3). Reverse flow is blocked until pilot pressure is applied at port 1. When the load pressure at port 3 rises above the pressure setting, the integral relief valve is activated and pressure is relieved from port 3 to port 2. APPLICATIONS CB - Counterbalance Valves VCB06-EN Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual cartridges can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center. Since this valve is piloted at port 1, no cross port drilling is required when dual cartridges are mounted nose to nose in an HIC. SPECIFICATIONS Rated pressure Rated flow at 22 bar (319 psi ) Leakage SCHEMATIC 350 bar [5075 psi]* 60 l/min [16 US gal/min] 10 drops/min @ at 70% of crack pressure Weight 0.21 kg [0.47 lb] Pilot ratio 4.1:1, 7.1:1 Cavity NCS06/3 * 350 bar with steel housing 210 bar with aluminum housing PERFORMANCE CB - 20 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent VCB06-EN DIMENSIONS mm [in] turn cw to increase pressure setting turn ccw to decrease pressure setting Load Holding Single Actuator Counterbalance Double Actuator VCB06-EN VCB06-EN VCB06-EN ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 21 CB - Counterbalance Valves VCB06-EN EXAMPLE CIRCUITS Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent VCB12-EN OPERATION The VCB12-EN is a cartridge style, 12-size metric counterbalance valve with hydraulic vent. This valve is 3- ported, externally piloted and low leakage. The check section allows free flow from the directional valve (port 2) to the load (port 3). Reverse flow is blocked until pilot pressure is applied at port 1. When the load pressure at port 3 rises above the pressure setting, the integral relief valve is activated and pressure is relieved from port 3 to port 2. APPLICATIONS CB - Counterbalance Valves VCB12-EN Single counterbalance valves are normally used when the load is unidirectional, such as aerial lifts, cranes, or winches. In load holding applications, they can be used as hose-break valves when installed near or within an actuator. Dual cartridges can be used for controlling loads bi-directionally in motor applications, or for cylinders going over center. Since this valve is piloted at port 1, no cross port drilling is required when dual cartridges are mounted nose to nose in an HIC. SPECIFICATIONS Rated pressure Rated flow at 22 bar (319 psi ) Leakage SCHEMATIC 350 bar [5075 psi]* 140 l/min [37 US gal/min] 10 drops/min @ at 70% of crack pressure Weight 0.7 kg [1.58 lb] Pilot ratio 4.7:1, 5.9:1. 6.9:1 Cavity NCS12/3 * 350 bar with steel housing 210 bar with aluminum housing PERFORMANCE psi bar 20 Pressure drop 26 cSt [125 SUS] hyd.oil @ 20° C[68°F] 250 15 200 150 10 100 5 50 0 0 l/min US gal/min CB - 22 35 10 70 140 105 20 30 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Hydraulic Vent VCB12-EN DIMENSIONS mm [in] M 33x2 turn cw to increase pressure setting turn ccw to decrease pressure setting CounterbalanceDouble Actuator Load Holding Single Actuator VCB12-EN VCB12-EN VCB12-EN ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 23 CB - Counterbalance Valves VCB12-EN EXAMPLE CIRCUITS Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent CP448-2 OPERATION This dual valve, internally piloted HIC is a low leakage counterbalance assembly with hydraulic vent. The CP448-2 uses two CP448-1 8-size cartridges and allows free flow from the V ports to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port. SPECIFICATIONS SCHEMATIC Rated pressure 350 bar [5075 psi]* Rated flow at 20 l/min [5 US gal/min] 22 bar (319 psi ) Weight 0.78 kg [1.72 lb] Pilot ratio 3:1, 4.5:1, 8:1 Cavity CIB * 350 bar with steel housing 210 bar with aluminum housing PERFORMANCE psi 435 bar 30 363 25 290 20 218 145 73 Pressure drop CB - Counterbalance Valves CP448-2 APPLICATIONS Dual counterbalance HIC’s are used for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator. 154 SUS (33 cSt) hyd. oil @ 100° F (38° C) piloted open 1 free flow 2 1 8.0:1 2 4.5:1 15 3.0:1 10 5 0 L/min 4 8 12 16 20 3.2 4.2 5.3 Flow US gal/min CB - 24 1.1 2.1 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent CP448-2 DIMENSIONS mm [in] turn ccw to increase pressure setting turn cw to decrease pressure setting 63.50 [2.50] 8.38 [0.33] 31.75 [1.25] 9.65 [0.38] 79.50 [3.13] 16.00 [0.63] 88.90 [3.50] C2 30.99 [1.22] C1 31.75 16.00 [1.25] [0.63] CB - Counterbalance Valves CP448-2 57.91 [2.28] EXAMPLE CIRCUITS Bi-directional Motion Control CP448-2 Bi-directional Load Holding CP448-2 ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 25 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent VCB06-EN-DL OPERATION This is a dual counterbalance HIC, 6-size metric, hydraulically vented, internally-piloted, low leakage, with a nose to nose design. The VCB06-EN-DL allows free flow from the V ports to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port. APPLICATIONS CB - Counterbalance Valves VCB06-EN-DL Use dual counterbalance HIC’s for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator. excavators. SPECIFICATIONS Rated pressure 350 bar [5075 psi]* Rated flow at 22 bar (319 psi ) Leakage 60 l/min [16 US gal/min] SCHEMATIC 10 drops/min @ at 70% of crack pressure Weight 1.02 kg [2.25 lb] Pilot ratio 4.1:1, 7.1:1 Cavity CIB * 350 bar with steel housing 210 bar with aluminum housing PERFORMANCE CB - 26 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent VCB06-EN-DL 16 [0.63] V2 VCB06-EN-DL VCB06-EN-DL CB - Counterbalance Valves VCB06-EN-DL V1 Bi-directional Counterbalance BSP 1/2 - SAE 8S 25 [0.98] HOLES Ø 6.5 EXAMPLE CIRCUITS BSP 3/8 - SAE 6S 34.5max [1.36] max 70 [2.75] 34 [1.34] 50 [1.97] 34.5max [1.36] max 30 [1.18] 35 [1.38] BSP 1/2 - SAE 8S C2 22.5 [0.89] 15 [1.18] mm [in] BSP 3/8 - SAE 6S C1 DIMENSIONS Counterbalance with Pressure Limiting ORDERING INFORMATION VCB06 - EN - 2 - A - 00 - B - XXX Counterbalance Valve, Pilot Port 1, 06 size (metric), external adjustment, hydraulic vent Code 1 2 3 Pilot Ratio 25-140 [363-2030] 70-210 [1015-3045] 105-350 [1523-5075] Code A B Pilot Ratio 7.1:1 4.1:1 11141716 • Rev CA • August 2015 Crack Pressure Setting [in bar] XXX: No factory setting/no stamping For customer specified settings, enter value in bar (Exemple 70 bar=70; 125 bar=125 ect.) Seal Option B V Seal Material BUNA Code Ports & Material 00 00 = Cartridge only DL3B AL, 3/8 BSP DL4B AL, 1/2 BSP DL6S AL, #6 SAE DL8S AL, #8 SAE VITON Seal kit 230000070 230000110 Body Nomenclature No Body NCS06/3-DL3/8 NCS06/3-DL1/2 NCS06/3-DL6S NCS06/3-DL8S CB - 27 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent DCB10-HV OPERATION DCB10-HV: Dual counterbalance HIC, 10-size, hydraulic vent. This is an internally piloted, low leakage assembly. The DCB10-HV uses 2 CB10-HV 10-size cartridges and allows free flow from the V port to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port. APPLICATIONS CB - Counterbalance Valves DCB10-HV Dual counterbalance HIC’s are used for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator. SPECIFICATIONS SCHEMATIC Rated pressure 350 bar [5075 psi]* Rated flow at 22 bar (319 psi ) Leakage 60 l/min [16 US gal/min] 10 drops/min @ at 70% of crack pressure Weight 0.90 kg [1.98 lb] Pilot ratio 3.0:1, 4.5:1, 10.0:1 Cavity CIB * 350 bar with steel housing 210 bar with aluminum housing EXAMPLE CIRCUIT Bi-directional Motor Control PERFORMANCE psi bar 25 300 26 cSt [121 SUS] hyd.oil at 50°C [122°F] DCB10-HV Pilot open 20 200 15 Free flow 10 100 5 0 10 3 CB - 28 20 6 30 40 9 50 12 60 l/min 15 US gal/min 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent DCB10-HV CB - Counterbalance Valves DCB10-HV DIMENSIONS BSP Ported - (Body Only) mm [in] D IAM 6.5 [0. 26] 35.00 [1.38] 35.00 [1.38] BSP Port BSP Port 17.5 [0.69] 67 [2.64] 38 [1.50] 20 [0.79] 38 [1.50] 70.00 [2.76] 33 [1.30] Bottom View 15 [0.59] 17.5 [0.69] 70 [2.76] 15 [0.59] BSP Port BSP Port 100.00 [3.94] ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 29 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent CP441-2 OPERATION This dual counterbalance, internally piloted catalog HIC is a low leakage assembly with hydraulic vent. This HIC uses 2 CP441-1 12-size cartridges and allows free flow from the V port to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port. APPLICATIONS SPECIFICATIONS Rated pressure SCHEMATIC 350 bar [5075 psi]* Rated flow at 115 l/min [30 US gal/min] 22 bar (319 psi ) Weight 1.26 kg [2.77 lb] Pilot ratio 3:1, 4.5:1, 10:1 Cavity CIB * 350 bar with steel housing 210 bar with aluminum housing PERFORMANCE psi 435 bar 30 363 25 290 20 218 145 73 Pressure drop CB - Counterbalance Valves CP441-2 Dual counterbalance HIC’s are used for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator. 154 SUS (33 cSt) hyd. oil @ 100° F (38° C) 15 10 free flow 5 0 L/min US gal/min CB - 30 pilot open 40 10.6 80 Flow 21.1 120 31.7 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent CP441-2 DIMENSIONS mm [in] Turn ccw to increase pressure setting Turn cw to reduce pressure setting V2 19.1 [0.75] 10.4 [0.41] 129.3 [5.09] 88.9 [3.50] V1 22.4 [0.88] 50.8 [2.00] 101.6 127.0 [4.00] [5.00] Bottom view 12.7 [0.50] Bottom view 82.6 [3.25] 44.5 [1.75] C1 C2 19.1 [0.75] 38.1 [1.50] Bi-directional Motor Control CP441-2 Bi-directional Load Control CB - Counterbalance Valves CP441-2 EXAMPLE CIRCUITS CP441-2 ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 31 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent VCB12-EN-DL OPERATION The VCB12-EN-DL is a dual counterbalance HIC, 12-size metric, hydraulically vented, internally-piloted, low leakage, with a nose to nose design. This catalog HIC allows free flow from the V ports to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port. APPLICATIONS CB - Counterbalance Valves VCB12-EN-DL Use dual counterbalance HIC’s for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator. SPECIFICATIONS SCHEMATIC Rated pressure 350 bar [5075 psi]* Rated flow at 22 bar (319 psi ) Leakage 140 l/min [37 US gal/min] 10 drops/min @ at 70% of crack pressure Weight 2.54 kg [5.60 lb] Pilot ratio 4.7:1, 5.9:1, 6.9:1 Cavity CIB * 350 bar with steel housing 210 bar with aluminum housing PERFORMANCE psi bar 20 Pressure drop 26 cSt [125 SUS] hyd.oil @ 20° C[68°F] 250 15 200 150 10 100 5 50 0 0 l/min US gal/min CB - 32 35 10 70 140 105 20 30 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent VCB12-EN-DL DIMENSIONS mm [in] turn cw to increase pressure setting turn ccw to decrease pressure setting CB - Counterbalance Valves VCB12-EN-DL EXAMPLE CIRCUITS VCB12-EN-DL Counterbalance with Pressure Limiting Bi-directional Motion Control VCB12-EN-DL ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 33 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent DCB20-HV OPERATION DCB20-HV: Dual counterbalance HIC, 20-size, hydraulic vent. This HIC is low leakage and internally piloted. The DCB20-HV uses 2 CB20-HV 20-size cartridges and allows free flow from the V port to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port. APPLICATIONS CB - Counterbalance Valves DCB20-HV Use dual counterbalance HIC’s for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator. SPECIFICATIONS Rated pressure Rated flow at 22 bar (319 psi ) Leakage SCHEMATIC 350 bar [5075psi]* 266 l/min [70 US gal/min] 10 drops/min @ at 70% of crack pressure Weight Aluminum 5.59 kg [12.59 lb] Ductile 10.68 kg [23.55 lb] Pilot ratio 3.0:1, 4.5:1, 10.0:1 Cavity CIB * 350 bar with steel housing 210 bar with aluminum housing PERFORMANCE CB - 34 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Hydraulic Vent DCB20-HV DIMENSIONS mm [in] turn ccw to increase presure setting turn cw to decrease pressure setting Bi-directional Counterbalance DCB20-HV Counterbalance with Pressure Limiting CB - Counterbalance Valves DCB20-HV EXAMPLE CIRCUITS DCB20-HV ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 35 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Atmospheric Vent VCB06-CN-DL OPERATION The VCB06-CN-DL is a dual counterbalance HIC, 6-size metric, nose to nose design with atmoshperic vent. This catalog HIC allows free flow from the V ports to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port. APPLICATIONS CB - Counterbalance Valves VCB06-CN-DL Atmospherically vented HIC’s are applied when it is not practical to connect a separate vent line to the tank. Use dual counterbalance HIC’s for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. SPECIFICATIONS SCHEMATIC Rated pressure 350 bar [5075 psi]* Rated flow at 22 bar [319 psi] Leakage 60 l/min [16 US gal/min] 10 drops/min @ at 70% of crack pressure Weight 0.96 kg [2.15 lb] Pilot ratio 4.1:1, 7.1:1 Cavity CIB * 350 bar with steel housing 210 bar with aluminum housing PERFORMANCE CB - 36 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Atmospheric Vent VCB06-CN-DL DIMENSIONS mm [in] CB - Counterbalance Valves VCB06-CN-DL turn cw to increase pressure setting turn ccw to decrease pressure setting EXAMPLE CIRCUITS VCB06-CN-DL Bi-directional Motion Control VCB06-CN-DL Counterbalance Double Actuator ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 37 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Atmospheric Vent DCB10-AV OPERATION DCB10-AV : Dual counterbalance HIC, 10-size, atmopheric vent. This HIC is low leakage and internally piloted. The DCB10-AV uses 2 CB10-AV 10-size cartridges and allows free flow from the V port to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port. APPLICATIONS CB - Counterbalance Valves DCB10-AV Atmospheric vented valves are applied when it is not practical to connect a separate vent line to the tank. Use dual counterbalance HIC’s for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator. SPECIFICATIONS Rated pressure Rated flow at 22 bar (319 psi ) Leakage SCHEMATIC 350 bar [5075 psi]* 60 l/min [16 US gal/min] 10 drops/min @ at 70% of crack pressure Weight 0.90 kg [1.98 lb] Pilot ratio 3.0:1, 4.5:1, 10.0:1 Cavity CIB * 350 bar with steel housing 210 bar with aluminum housing EXAMPLE CIRCUITS Bi-directional Motor Control DCB10-AV PERFORMANCE psi bar 25 300 26 cSt [121 SUS] hyd.oil at 50°C [122°F] Pilot open 20 200 15 Free flow 10 100 5 0 10 3 CB - 38 20 6 30 40 9 50 12 60 l/min 15 US gal/min 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Atmospheric Vent DCB10-AV DIMENSIONS Cross-sectional view SAE - Ported mm [in] D IAM CB - Counterbalance Valves DCB10-AV BSP Ported - (Body Only) 6.5 [0. 26] 35.00 [1.38] 35.00 [1.38] BSP Port BSP Port 17.5 [0.69] 67 [2.64] 38 [1.50] 20 [0.79] 38 [1.50] 70.00 [2.76] 33 [1.30] Bottom View 15 [0.59] 17.5 [0.69] 70 [2.76] 15 [0.59] BSP Port BSP Port 100.00 [3.94] ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 39 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Atmospheric Vent VCB12-CN-DL OPERATION The VCB12-CN-DL is a dual counterbalance HIC, 12-size metric, nose to nose design with atmoshperic vent. This catalog HIC allows free flow from the V ports to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port. APPLICATIONS CB - Counterbalance Valves VCB12-CN-DL Atmospherically vented valves are applied when it is not practical to connect a separate vent line to the tank. Use dual counterbalance HIC’s for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. SPECIFICATIONS Rated pressure SCHEMATIC 350 bar [5075 psi]* Rated flow at 140 l/min [37 US gal/min] 22 bar (319 psi ) Weight 2.92 kg [6.45 lb] Pilot ratio 4.7:1, 5.9:1, 6.9:1 Cavity CIB * 350 bar with steel housing 210 bar with aluminum housing PERFORMANCE psi bar 20 Pressure drop 26 cSt [125 SUS] hyd.oil @ 20° C[68°F] 250 3 2 15 200 150 10 100 5 2 50 0 0 l/min US gal/min CB - 40 35 10 70 3 140 105 20 30 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - Atmospheric Vent VCB12-CN-DL DIMENSIONS mm [in] turn cw to increase pressure setting turn ccw to decrease pressure setting VCB12-CN-DL Bi-directional Motion Control CB - Counterbalance Valves VCB12-CN-DL EXAMPLE CIRCUITS VCB12-CN-DL Counterbalance Double Actuator ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 41 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - w/ Makeup Checks, Catalog HIC DCB10-MC OPERATION Dual counterbalance HIC, 10-size, hydraulic vent with make-up checks. This is an internally piloted, low leakage assembly. The DCB10-MC uses two CB10-HV cartridges and four CP100-3 check valves, allowing free flow from the V port to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port. Connect the T port to a tank line to allow for make-up flow into the circuit. APPLICATIONS CB - Counterbalance Valves DCB10-MC Dual counterbalance HIC’s are used for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator. When make-up feature is needed, connect ‘T’ port to reservoir or charge system. This allows the load to be smoothly controlled with minimum energy loss. If load tries to run ahead of pump, pilot pressure will decrease and the relief section will throttle or close to prevent runaway. The T port is also useful in cylinder applications where directional valves (specifically proportional valves) are sensitive to flow intensification of powering the rod side. The DCB10-MC diverts flow directly to tank and bypasses the directional valve. This HIC technically replaces the 1EEC11-01. SPECIFICATIONS Rated pressure 350 bar [5075 psi]* Rated flow at 22 bar (319 psi ) Weight 57 l/min [15 US gal/min] Pilot ratio Cavity C1 C2 2.39 kg [5.27 lb], Aluminum 5.04 kg [11.11 lb], Ductile 3.0:1, 4.5:1, 10.0:1 CIB PERFORMANCE CB - 42 SCHEMATIC V1 T V2 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - w/ Makeup Checks, Catalog HIC DCB10-MC DIMENSIONS CB - Counterbalance Valves DCB10-MC EXAMPLE CIRCUITS ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 43 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - w/ Makeup Checks, Catalog HIC DCB12-MC OPERATION Dual counterbalance HIC, 12-size, hydraulic vent with make-up checks. This is an internally piloted, low leakage assembly. The DCB12-MC uses two CP441-1 cartridges and four CP100-3 check valves, allowing free flow from the V port to the C ports and blocks flow in the reverse direction until the relief setting is reached, or until adequate pilot pressure has been applied to the opposite V port. Connect the T port to a tank line to allow for make-up flow into the circuit. APPLICATIONS CB - Counterbalance Valves DCB12-MC Dual counterbalance HIC’s are used for controlling loads in bidirectional motion such as wheel motor applications or for cylinders going over center. They are also suitable for use on the boom and dipper cylinder on an excavator. When make-up feature is needed, connect ‘T’ port to reservoir or charge system. This allows the load to be smoothly controlled with minimum energy loss. If load tries to run ahead of pump, pilot pressure will decrease and the relief section will throttle or close to prevent runaway. The T port is also useful in cylinder applications where directional valves (specifically proportional valves) are sensitive to flow intensification of powering the rod side. The DCB12-MC diverts flow directly to tank and bypasses the directional valve. This HIC technically replaces the 1EEC12-01. SPECIFICATIONS Rated pressure Rated flow at 22 bar (319 psi ) Weight Pilot ratio Cavity 210 bar [3045 psi], Aluminum 350 bar [5075 psi], Ductile C1 C2 95 l/min [25 US gal/min] 3.13 kg [6.90 lbs], Aluminum 6.98 kg [15.39 lbs], Ductile 3.0:1, 4.5:1, 10.0:1 CIB PERFORMANCE CB - 44 SCHEMATIC V1 T V2 11141716 • Rev CA • August 2015 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Dual Counterbalance - w/ Makeup Checks, Catalog HIC DCB12-MC DIMENSIONS CB - Counterbalance Valves DCB12-MC EXAMPLE CIRCUITS ORDERING INFORMATION 11141716 • Rev CA • August 2015 CB - 45 Table of Contents/Introduction Quick Reference Index Counterbalance Valves Catalog Notes CB - Counterbalance Valves Notes CB - 46 11141716 • Rev CA • August 2015