3/20/22, 1:20 PM NEPSI - Total Harmonic Voltage Distortion Calculator CALCULATION OF TOTAL HARMONIC VOLTAGE DISTORTION The following calculator computes the total harmonic voltage distortion, Peak Voltage, RMS Voltage, and Crest Factor based on individual harmonic voltage distortion values between the 1st and the 50th harmonic. Input the fundamental voltage and individual harmonic voltages to compute results also to view a waveform plot based on the input values. The waveform plot assumes all phase angles for individual voltage distortion values to be zero degrees (in phase with the fundamental voltage). When inputting the data, be sure to use consistent units of Volts, KV, or Per Unit Volts. Additionally, be consistent with either line-to-line values or line-to-neutral values. Formulas and Variables Of Interest... Total Harmonic Voltage Distortion or THD, of a signal is a measurement of the harmonic distortion present and is defined as the ratio of the sum of the power of all harmonic components to the power of the fundamental frequency. THD is used to characterize the power quality of electric power systems. Distortion factor is a closely related term and sometimes used as a substitute term. IEEE 519, "Recommended Practices and Requirements for Harmonic Control in Electrical Power Systems" provides suggested limits for harmonic voltage distortion as shown in Table 10.4 below. A 5% voltage distortion is barely noticeable on a voltage waveform plot but can result in power quality issues. This is especially true in an environment where resonance may exist at the frequency of the individual harmonic voltage that contributes to the total harmonic voltage distortion. Harmonic Filters sold by NEPSI can be used to mitigate and reduce voltage distortion on utility and industrial power systems. Crests Factor is a measure of a waveform showing the ratio of the peak value to the RMS value. A crest factor of 1.0 indicates no peaks, such as the case with DC Voltage. A voltage waveform with 0% THD will have a crest factor equal to 1.414. Crest Factors greater than 1.414 usually indicates the presence of harmonic distortion. Calculator Known variables: Fundamental Frequency Voltage, Harmonic Voltages V1 V2 V3 V4 V5 V6 100.00 0.52 1.32 0.27 1.58 0.60 V11 V12 V13 V14 V15 V16 1.47 0.23 1.05 0.12 0.14 0.11 V21 V22 V23 V24 V25 V26 https://www.nepsi.com/resources/calculators/total-harmonic-voltage-distortion.htm 0.15 0.08 0.79 0.07 0.52 0.08 V31 V32 V33 V34 V35 V36 0.32 0.06 0.11 0.06 0.38 0.06 V41 V42 V43 V44 V45 V46 0.24 0.07 0.20 0.06 0.09 0.05 1/2 3/20/22, 1:20 PM V7 V8 V9 V10 NEPSI - Total Harmonic Voltage Distortion Calculator V17 1.64 0.28 0.23 0.23 V18 V19 V20 0.60 0.18 0.69 0.09 V27 V28 V29 V30 Total Harmonic Voltage Distortion (THD): Perunit Total Harmnic Voltage Distortion (THD): Peak or Crest Voltage: RMS Voltage: Creast Factor: 0.13 0.08 0.44 0.06 3.7% 0.037 164.38 100.07 1.643 V37 V38 V39 V40 0.33 0.06 0.11 0.07 V47 V48 V49 V50 0.16 0.05 0.10 0.05 Fundamental Frequency Waveform Distorted Waveform Unable to load Flash content. The Charts Control requires Flash Player 9.0.45 or higher. You can download the latest version of Flash Player from the Adobe Flash Player Download Center 0 0.03 0.06 0.09 0.12 0 15 164.3788277165 141.4 160.5451427103 141.3363747721 152.5831939714 141.1455563468 146.6898988852 140.8277164478 144.7422574105 140.3831411097 143 7602168656 139 8122304201 https://www.nepsi.com/resources/calculators/total-harmonic-voltage-distortion.htm 10000 0.2704 1.7424 0.0729 2.4964 0 36 2/2