NO Severity Specific problem MO 1 CRITICAL Heartbeat Failure #N/A 2 MAJOR Clock Calibration Expiry Soon Cabinet 3 MAJOR Disconnected EquipmentSupportFunction 4 5 MAJOR MAJOR FanFailure File System Diagnostic Error Cabinet PlugInUnit 6 MAJOR GeneralHwError HwUnit 7 MAJOR Gigabit Ethernet Link Fault GigaBitEthernet 8 MAJOR Loss of Tracking Synchronization 9 MAJOR NTP System Time Sync Fault TimeSetting 10 MAJOR NumberOfHwEntitiesMismatch EquipmentSupportFunction 11 MAJOR Packet Server Availability Fault PacketFrequencySyncRef 12 MAJOR PLMN Service Unavailable EUtranCellFDD 13 MAJOR Service Unavailable EUtranCellTDD 14 MAJOR Sync Reference PDV Problem Synchronization 15 MAJOR Synch Reference Not Reliable Synchronization 16 MAJOR TemperatureSensorFailure HwUnit 17 18 19 MAJOR MAJOR MAJOR Upgrade Package Corrupt Suspected Sleeping Cell Resource Allocation Failure UpgradePackage EUtranCellFDD EUtranCellTDD 20 MAJOR LicenseKeyMissing OptionalFeatureLicense 21 MINOR External Link Failure ENodeBFunction 22 MINOR HwFault AuxPlugInUnit=RRU 23 MINOR InconsistentConfiguration RiPort 24 MINOR Link Failure RiLink 25 MINOR PowerFailure AuxPlugInUnit 26 MINOR Remote IP Address Unreachable Sctp 27 MINOR Service Degraded EUtranCellTDD 28 MINOR GeneralSwError DeviceGroup=ru 29 MINOR RF Reflected Power High AuxPlugInUnit=RRU 30 WARNING EnclosureProductDataMismatch Cabinet 31 WARNING Link Stability RiLink 32 WARNING SFP Stability Problem RiPort 32 Probable Cause LAN ERROR/COMMUNICATION ERROR CLOCK_SYNCHRONISATION_PROBLEM EQUIPMENT_MALFUNCTION EQUIPMENT_MALFUNCTION DISK_PROBLEM EQUIPMENT_MALFUNCTION LOSS_OF_SIGNAL REPLACEABLE_UNIT_PROBLEM CLOCK_SYNCHRONISATION_PROBLEM CONFIGURATION_OR_CUSTOMIZING_ERROR UNAVAILABLE UNAVAILABLE UNDERLYING_RESOURCE_UNAVAILABLE CLOCK_SYNCHRONISATION_PROBLEM CLOCK_SYNCHRONISATION_PROBLEM EQUIPMENT_MALFUNCTION FILE_ERROR THRESHOLD_CROSSED CONFIGURATION_OR_CUSTOMIZING_ERROR CONFIGURATION_OR_CUSTOMIZING_ERROR LINK_FAILURE EQUIPMENT_MALFUNCTION CONFIGURATION_OR_CUSTOMIZING_ERROR EQUIPMENT_MALFUNCTION POWER_SUPPLY_FAILURE unreachableIpAddress: *10.159.59.81 (sample IP Service MME) PERFORMANCE_DEGRADED SOFTWARE_ERROR REFLECTED_POWER_TOO_HIGH CONFIGURATION_OR_CUSTOMIZING_ERROR LINK_FAILURE SFP RX-LOW_PWR alarm Cause/AdditionalInfo Service _ X L : c o Impacted l d Power Failure, DUS problem, Transport problem, OAM IP wrong YES The Alarm is secondary Alarm, will raise along with other primary alam such as: Packet Server Availability Fault, Synch Reference Not Reliable. If both Packet Sync Ref are "UNAVAILABLED", this "Clock Calibration Expiry Soon" will be raised. YES Lost contact with the node that controls external alarms, power and climate HW, cabinetIdentifier N/A Result: /c nok, /d ok This alarm is raised if there is a hardware fault in a support system unit. The alarm indicates that the unit must be replaced, there is an unrecoverable hardware fault Autonegotiation Failed to Meet Minimum Requirements This Alarm will impacting Services if both SyncReference (Synchronization=1,PacketFrequencySyncRef=1 & Synchronization=1,PacketFrequencySyncRef=2) having "Loss of Tracking". This quite related to transport bandwidth which also simillar symptom impcating "Sync Reference PDV Problem" Alarm. Related Link towards PTP Servers r e s t a r t o n 1 9 NO F e b NO , NO d o u b e c NO h e c k t h e NO a l a r NO (If have standby)m NTP sync alarm Message: NTP general problem NO SAU, SCU, PDU that is not configured detected NO r a i s e a g a i n o NO (If have standby)r UNAVAILABLE n YES (if both o "PacketSyncRef" t DISABLED) The Alarm is secondary Alarm, will raise along with other primary alam such as: Packet Server Availability Fault, Synch Reference Not Reliable. If both Packet Sync Ref are "UNAVAILABLED", all EUtranCellFDD will "DISABLED" and this "PLMN Service Unavailable" will be raised. YES The Alarm is secondary Alarm, will raise along with other primary alam such as: Hw Fault, No Connection, Inconsistent Configuration, PowerFailure, Current Too High YES This Alarm will impacting Services if both SyncReference (Synchronization=1,PacketFrequencySyncRef=1 & Synchronization=1,PacketFrequencySyncRef=2) having "Sync Reference PDV Problem". This quite related to transport bandwidth which also simillar symptom impcating "Loss of Tracking" Alarm. Related Link towards PTP Servers NO (If have standby) UNAVAILABLE NO (If have standby) The alarm is raised when an RBS is configured with an external fan group, and the Support Control Unit (SCU) temperature sensor function reports a fault UNAVAILABLE Drop in RRCs No available carrier path ,adjacent filter branch not available Depends on which License Key NO NO (if different UP) YES YES YES / NO X2 link problem to one or several neighbouring eNodeBs NO Not functional carrier HW resources (Mixed Mode). (This alarm will raised the secondary alarm: "Service Unavailable"). YES Either the CPRI cable is wrongly connected or there is a configuration fault YES Not in operation, additionalData: id 1, unitId 1, portNo 0, cause BER LOS (Mixed Mode) YES Incoming power supply failure to RU/RRU YES Fault in remote node or fault in IP network NO (If MME Pool) The Alarm is secondary Alarm, will raise along with other primary alam such as: Hw Fault, No Connection, Inconsistent Configuration, PowerFailure, Current Too High NO Timeout when trying to access radio. (This alarm will raised the secondary alarm: "Service Degraded"). YES The alarm is raised when the measured RF reflected power in the radio unit exceeds a predefined threshold. (This alarm will raised the secondary alarm: "Service Degraded"). NO The Cabinet managed object is empty or if the attribute NO Temporary not in operation, additionalData: id 1, unitId 1, portNo 0, cause version/revision mismatch(10) (Mixed Mode) The alarm is currently toggling YES A measured SFP condition is below/above a threshold value. NO Method of troubleshoot (Combination between Experienced & Alex/CPI) Check the transport part If transport part OK, check VLAN IP OAM If all above ok, Check on site and troubleshoot on the physical hardaware / connection, Clear the primary alarm, this alarm will be ceased Refer to CPI as attached: Check Fan Unit at site Cold Restart DUS (if the alarm remain, change DUS) 1.Identify and restart the faulty board or unit. See Restart Board for instructions. 2.Check that the alarm has ceased. 3.If the alarm remains, identify and lock the faulty board or unit. See Lock Board for instructions. 4.Replace the faulty board or unit. See Replacing Alarm Units, Replacing Control Units, Replacing Power Units or Replacing EMU for instructions. 5.Unlock the board or unit. See Unlock Board for instructions configuredSpeedDuplex must be equal/match with actualSpeedDuplex Try to reset "Loss of Tracking" on impacted TransportNetwork=1,Synchronization=1,PacketFrequencySyncRef "get ntp", check the Ntp Server Ip Address. For LTE Phase-1 and Phase-2, the Server-1 IP is (10.200.170.116) & Server-2 IP is (10.203.178.165). If wrong IP, do change the IP address. Alarm will be ceased. In normal condition, ,NtpServer=1 service status is "6 (SYSPEER)" and NtpServer=2 service status is "4 (CANDIDATE)". Or Either one NtpServer service status is "6 (SYSPEER)". Need to check on site. Check on EPC Bus cable to SAU, SCU, PDU Check both IP adressed of PTP Server are correct (follow ATND). If all IP and VLAN address are correct, need to check on Transport (PDH, SDH, ME, PE Router) and NTP Server it self (Hardware/Software) Clear the primary alarm, this alarm will be ceased Clear the primary alarm, this alarm will be ceased Warm Restart DUS and if not cease, check transport bandwidth bottle neck Check both IP adressed of PTP Server are correct (follow ATND). If all IP and VLAN address are correct, need to check on Transport (PDH, SDH, ME, PE Router) and NTP Server it self (Hardware/Software) 1.Check if the SCU is equipped with an external temperature sensor. a.If it is, replace the external temperature sensor as instructed in Replacing Fans and Climate Units, and then restart the SCU as instructed in Restart Board. b.If it is not, replace the SCU as instructed in Replacing Control Units. 2.Check that the alarm has ceased Delete the corrupted upgrade package (make sure not the current UP) LOCKED Impacted Cell for 8 seconds and UNLCOKED it Restart impacted RRU/RU or DUS Warm Restart Instal complete LKF / inject optional required LKF. Always check "st cell & ue print -admitted" Tunnelling Issue in ME Transport Restart RRU, check "st cell", if still not up, check "cabx", can see normally RRU faulty Check configuration, cabx and probably need to check on site on the RiLink connection between DUS RRU Restart impacted RRU/RU. If "No connection with ManagedElement=1,Equipment=1,AuxPlugInUnit=RRU-1", then need to check on site on the RiLInk/SFP's connection between DUS-RRU Related to "Heartbeat Failure", need to check RU & DU power at site Check on MME IP Service, S1_MME Vlan. All good, its more towards Transport issue (SCTP) Clear the primary alarm, this alarm will be ceased Restart impacted RRU Need to check on site, due to problems in the antenna cable or in the RF connector set Equipment=1,Cabinet=1 productData, or if product data not available, copy from 3G product data Restart impacted RRU/RU. If "No connection with ManagedElement=1,Equipment=1,AuxPlugInUnit=RRU-1", then need to check on site on the RiLInk/SFP's connection between DUS-RRU Possible SFP module malfunction which can lead to reduced bit rate, erroneous data, or laser failure. Check on-site NO Specific problem 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Heartbeat Failure Clock Calibration Expiry Soon Disconnected FanFailure File System Diagnostic Error GeneralHwError Gigabit Ethernet Link Fault LicenseKeyMissing Loss of Tracking NTP System Time Sync Fault NumberOfHwEntitiesMismatch Packet Server Availability Fault PLMN Service Unavailable Resource Allocation Failure Service Unavailable Suspected Sleeping Cell Sync Reference PDV Problem Synch Reference Not Reliable TemperatureSensorFailure Upgrade Package Corrupt External Link Failure GeneralSwError HwFault InconsistentConfiguration Link Failure PowerFailure Remote IP Address Unreachable RF Reflected Power High Service Degraded EnclosureProductDataMismatch Link Stability SFP Stability Problem Grand Total CRITICAL MAJOR MINOR 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 19 9 WARNING Grand Total 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 3 32 Count - Specific problem MO AuxPlugInUnit AuxPlugInUnit=RRU Cabinet DeviceGroup=ru ENodeBFunction EquipmentSupportFunction EUtranCellFDD EUtranCellTDD GigaBitEthernet HwUnit OptionalFeatureLicense PacketFrequencySyncRef PlugInUnit RiLink RiPort Sctp Synchronization TimeSetting UpgradePackage #N/A Total Result Severity CRITICAL MAJOR MINOR WARNING Total Result 1 2 2 1 1 1 2 2 2 1 2 1 1 1 1 1 1 1 1 1 9 3 3 1 1 1 1 19 1 2 3 1 1 2 2 3 1 2 1 1 1 2 2 1 3 1 1 1 32