Scaffold Appreciation Mobile Towers Tower Scaffolds Used by painters and others who need to do lightweight work from a structure that can be readily moved from place to place Can be made from normal tube and fitting Can be lightweight aluminium proprietory systems (more common) Foundation Should only be used on firm ground Mobile towers should only be used on hard level surfaces Castors should be fitted with brakes and locked into standards Castors should not be less than 125mm in diameter The maximum permitted load should be stamped onto castors Stability Totally dependent on the height to least base ratio Aluminium towers have a higher centre of gravity and are less stable When exposed to wind loading it is better to tie the tower to the structure If this is not possible ground anchors or kentlidge must be considered Working Platforms Platforms must be fully boarded and at least 600mm wide If used for materials they must be 800mm wide Must be fixed by cleats to prevent tipping Any hatches should be closed when the platform is not in use Loads should be evenly distributed Access The tower must have a safe means of access and egress Access should be by internal ladder and trapdoor Access should never be by means of an external ladder Climbing the horizontal members should not be permitted Rungs no more than 300mm apart and stiles no more than 480mm apart Use of Towers A ladder or trestle must never be placed on top of a tower to extend height. This will cause instability Mobile towers should have their castors turned outwards with the brakes locked on during use Mobile towers should be moved only by pushing or pulling the base, never dragged from the top All materials and tools should be removed before movement Height Limitations Mobile Towers Internal 3.5:1 External 3:1 The height is measured to the platform level Recommended maximum height for mobile towers is 9.6m and static 12m Stabilisers Stabilisers may have pad feet or outriggers with castors They add to the least base dimension General Advice Vertical members are usually secured by spigot joints. It si imperative that these are properly seated and the locking pins engaged All components must be inspected before and checked for damage, cracks, broken welds or any defect that may affect the tower Where cross members and diagonal bracing are connected by latching hooks and triggers, these should be inspected to ensure that they are working correctly prior to use