Uploaded by samiul mostafiz inzam

ESD Final-Assignment 18-38053-2 Resubmit

advertisement
Electrical Service Design Lab
Video Demonstration for OBE assessment
Student Name: Labib Mohammad Mashrafi
Submission Date: 02-12-2021
ID: 18-38053-2
Dept: EEE
Semester: Fall 2021-2022
Section: A
Marking Rubrics 1 for assessing CO1 [P.c.3.C4] (to be filled by faculty)
Markings
Excellent [3]
Acceptable [2]
Inadequate [1]
No response [0]
Major
design
requirements
are
identified.
Basic
design
strategy is
defined.
Partial
design N/A
essentials are listed
with no
design
strategy is defined.
Secured Marks
Points
Type of wire
All
design
requirements
are
clearly
identified
and proposed. A
detail
design
strategy is defined.
Public health issues All constrains are
fully taken
into
considerations and
identified with
a
comprehensive
explanation
Safety issues
Most of the issues
are identified with
proper explanation
Society issues
Environmental
issues
Not all but major Only
partial N/A
constraints
are consideration
of
considered. But not design constraints
fully integrated with
design.
Moderate amount of
issues is identified
with
minimum
explanation
Most of the issues
Moderate amount of
are identified with issues is identified
proper explanation with
minimum
explanation
Most of the issues
Moderate amount of
are identified with issues is identified
proper explanation with
minimum
explanation
Least amount
of N/A
issues is identified
with no
proper
explanation
Least amount
of N/A
issues is identified
with no
proper
explanation
Least amount
of N/A
issues is identified
with no
proper
explanation
Total =
Out of 15
Marking Rubrics 2 for assessing CO2 [P.f.1.A3] (to be filled by faculty)
Markings
Excellent [3]
Acceptable [2]
Inadequate [1]
No response [0]
Wire selection
Exact calculation
of current has done
before selecting
wire AWG. Proper
method of
calculation is
followed
Nearly correct
calculation is used
to identify the wire
AWG
Wrong calculation
with incorrect
method is used to
identify wire AWG
N/A
Wire classification
Different type of
wire classification
is shown. Clear
explanation is used
to identify wires
for branch circuit
Several type of
wire classifications
points out but
explanation is not
proper during
selection
Least amount of
wire classification
with no
explanation
N/A
Market research
Immense market
research has been
done for wires
availability
Average Market
research
Market research
does not reflect
anything
meaningful
N/A
Safety percussions
Most of the issues
are identified with
proper explanation
Moderate amount
of issues is
identified with
minimum
explanation
Least amount of
issues is identified
with no proper
explanation
N/A
Health issues
during setup
Most of the issues
are identified with
proper explanation
Moderate amount
of issues is
identified with
minimum
explanation
Least amount of
issues is identified
with no proper
explanation
N/A
Points
Secured
Marks
Total =
Out of 15
Question: Analyze a plan for feeder and branch circuit wiring incase of AIUB. For feeder circuit
wiring please address these issues like type of wire, public health issues, safety issues, societal and
environmental issues as well. For branch circuit wiring, selection procedure is little bit different than
the feeder circuit. You need to focus in these topics like wire selection, classification, market
research, safety percussion and health issue as well. Please make a power point presentation along
with a clear video demonstration and send the link of your demonstration in my mail.
Design of a Single Line Diagram (SLD) 400V
AC Power Distribution.
General Notes:
a. This Single-line diagram shows the electrical system functional design. For equipment
details refer to specific vendor supplied drawings. For installation details refer to specific
layout and arrangement drawings.
b. The installation shall be in accordance with the requirements of: IEC, where the
requirement of those drawings differ from the above regulation.
c. The electrical system shall be designed:
• 1000kV/400V transformer operating.
• Circuit Breaker frame sizes are typical.
• All cables are to be from bottom using removal type.
• Necessary earthing terminal to be provided.
• All electrical fittings shall be suitable for ambient temperature.
• Insulated copper bus bar shall be in accordance with latest IEC requirement.
• To prevent the standby transformer from being energized by the main
transformer.
Single Line Diagram
The single-line diagram is the blueprint for electrical system analysis. ... It shows a correct power
distribution path from the incoming power source to each downstream load – including the
ratings and sizes of each piece of electrical equipment, their circuit conductors, and their
protective devices.
Fig: Single Line Diagram.
Element of Single Line Diagram
33/11KV Substation Single Line Diagram
18-38053-2
Fig: Circuit Diagram of Single Line Diagram.
A single line diagram, also referred to as a one-line diagram, is usually a single page document
that represents a facilities electrical distribution infrastructure. It will have one single line shown
for bus (or cable) to represent all three phases.
Lab Report 06
Lesson 1- Design Environment
Lesson 2- Basic Workflow, Part 1
Lesson 3- Basic Workflow, Part 2
Lesson 4- Schematic Editing
Lesson 5- Panel Layouts
Lesson 6- Reports
Lab Report 07
1
2
3
4
5
6
Lab Report 08
Download