New SCION Gas Chromatograph Providing Performance and Flexibility . Topics • Feature summary • 436-GCMS • 456-GCMS • Pre-defined Hardware • Standard Analyzers • Custom Solutions • GC Consumables • Key Benefits • Highlight s . The SCIONTM GC Series Designed for: • Productivity • Performance . SCION 436/456-GC Product Highlights Available Inlets • Split / Splitless • PTV / LVI • Cold-On-Column • Packed/Wide Bore • Flash Available Detectors • • • • • • • FID --> Hydrocarbon TCD --> ≠ Carrier gas ECD --> Electrofilic PFPD --> Organo S & P NPD --> Organo N & P PDHID --> Trace Gases MS --> Best for Qualitative & Quantitative Provides customers with a LOT of options • Accommodate wide range of applications . SCION 436-GC Product Highlights 2 Channel Architecture Supports 2 Injectors, 1 GC Detector and MS (Total 2’s Detector) Automation Capabilities 600 Hz Data Rate Detectors Full EFC Capability Up to 3 modules Resolution 0.001 psi One Back Flush option Color Touch Screen Display and Interface High Pressure Injection Ports Range 0 – 150psi Powerful CompassCDS Software Small Footprint, Saves Benchspace High Performance Oven, fast ramping rate 170⁰C/min “Inert GC” Option . SCION 456-GC Product Highlights 4 Channel Architecture Supports 3 Injectors, 3 Detectors plus SQ or TQ ( Total 4’s det) Automation Capabilities 600 Hz Data Rate Detectors Full EFC Capability Up to 9 modules 21 channels Resolution 0.001 psi Color Touch Screen Display and Interface Back Flush option High Pressure Injection Ports Range 0 – 150psi Powerful CompassCDS Software Capabilities That Make a Difference “Inert GC” Option . Large High Performance Oven, fast ramping rate 150⁰C/min (180 ⁰C/min with Oven Reducer) SCION 436-GC and 456-GC User Interface • Larger • 9”, Full Colour • WVGA Resolution • (800 x 480) • Multi-language • 14 languages • Local Control • Touch Screen • Hard keys • Remote access • GC Portal software . Global Interface Easing adaptation to your lab • • • A truly global platform • Supporting 14 languages with more developing Includes full instrument control • All instrument functions easily accessible from intuitive organization Now including routine Mass Spectrometer control • Tuning initiation • Vent and maintenance protocols . GC Remote Control Control the GC in the exact same way and with the same level of functionality as if they were standing at the GC using the User Interface but from a remote location . SCION 436-GC and 456-GC • Multi-language User Interface • Full EFC Capability • Pressure Range 0 – 150psi • Resolution 0.001 psi • Power Failure Function • 600Hz Data Rate on all Detectors • Fast Oven Ramp Up Time • Certified (ATEX) • Personal safety on the lab • No flying parts after an “explosion” . SCION GC - Oven Fast Temperature Ramping • 436-GC 170⁰C/min • 456-GC 150⁰C/min (180 ⁰C/min with Oven Reducer) Large Oven Volume • • • • • Conventional columns used Easy to install columns, valves etc. Capacity for several columns Good access. Oven door easily removed 456-GC Largest Oven in the industry Both Models: • Set Point Resolution 0.1⁰C • Cool down 400⁰C to 50⁰C in 4.5 minutes • 24/25 program ramps/holds . SCION 436/456-GC Series - EFC • EFC Resolution: 0.001 psi Retention Time Repeatability Area Reproducibility n-C14 n-C15 n-C16 n-C14 n-C15 n-C16 Average 6.0407 6.6858 7.3306 Average 197179.7 197474.7 199297.6 RSD 0.0004 0.0003 0.0006 RSD 1116.17 1127.28 1152.98 %RSD 0.0061 0.0052 0.0079 %RSD 0.566 0.570 0.578 Measured under standard conditions in splitless mode using CP-8400 autosampler. Different conditions and/or samples will affect the results. Measured under standard conditions in splitless mode using CP-8400 autosampler. Different conditions and/or samples will affect the results. RT Repeatability <0.008% Area Repeatability <1.0% Area Repeatability <0.4% with Autosampler . Conventional analysis of Diesel • • • • • 13 Reduce column ID from 0.25 to 0.1mm Reduce column length from 15 to 4 mtr Increase column head pressure from 7 to 21.045 psi Increase ramp from 10 to 65 ºC/min Increase data rate from 25 to 200 Hz . Speed increased with a factor 6.5 0 14 5 10 15 . 20 25 SCION SQ Differentiating Features 1. Patented Lens-Free Optical Path 2. Axial Ion Source 3. 1 Active-focusing Heated Curved q0 4. High-capacity turbomolecular pump 5. High-Speed orthogonal integrated detector with Extended Dynamic Range (EDR) technology • • 5 4 3 Multi-axis noise cancelling design High-speed digital electronics that allow 14,000Da/s scan speeds 5 . 2 ‘Lens-Free’ Design (Patented) 1 Ø Lens-free Design No lenses or apertures in the ion optical path - US Patent 6576897 Ø No lenses or apertures to contaminate, charge-up or clean Ø No additional electronics to power lenses Ø Efficient ion transmission from q0 to Q1, and from Q1 to detector User Benefit: Ease-of-Use, No Tuning, Improved Sensitivity 6 . Lens-free Design User Benefit: Ease-of-Use, No Tuning, Improved Sensitivity 6 . 2 Axial Ion Source Ø Ions generated on-axis from column Ø Inert materials Ø Dual filaments for higher productivity To q0 From GC Ø Plug-n-Play modules for easy conversion to CI User Benefit: Highly Robust 7 . SCION SQ Select- 1% Diesel Fuel Injections Injection # 1 SCION Select Injection # 300 SCION Select Robust Operation for routine applications! 8 . 3 Ø Ø From Ion Source 90 degree for max. robustness • Ions from the source come under the influence of the RF-field and are turned into Q1 • Neutrals continue to travel in straight line and are pumped away by the vacuum system – higher S/N Ceramic heater circuit Heated q0 Option • Ø Active-focusing q0 Ion Optics Front of the assembly is heated to 135C to ensure there are no cold spots To Q1 Active-focusing Option • Ability to introduce helium gas into q0 to enhance sensitivity Patented rf couplers to improve transmission (part of Lens-Free architecture) User Benefit: High Sensitivity & Robustness 9 . Active-focusing q0 71% 128% 93% 42% He On He Off Hexachlorocyclopentadiene Benzene Hexachloro 1 0 . Atrazine Heptachlor q0 Helium ON/OFF Ratio on Select Compounds Compound Name Area Height SS-Benzene, 1,3-dimethyl-2-nitro- 1.7 1.6 Hexachlorocyclopentadiene 1.7 1.7 2,6-Dinitrotoluene 1.4 1.4 Acenaphthene-d10 1.8 1.9 2,4-Dinitrotoluene 1.4 1.4 Propachlor 1.5 1.5 Benzene, hexachloro- 2.0 2.3 Simazine 1.6 1.7 Atrazine 1.9 1.9 Lindane 1.8 1.7 Phenanthrene-d10 1.9 1.9 Metribuzin 1.7 1.8 Alachlor 1.8 1.7 Heptachlor 1.4 1.4 Metolachlor 1.8 1.8 Cyanazine 2.0 2.2 Compound Name Aldrin Heptachlor epoxide gamma-Chlordane SS-Pyrene-d10 Butachlor alpha-Chlordane trans-Nonachlor Dieldrin Endrin . Area 1.4 2.3 2.3 1.9 1.8 2.3 2.3 1.5 1.5 Height 1.4 2.3 2.2 1.8 1.8 2.2 2.3 1.5 1.6 Bis(2-ethylhexyl)adipate 1.4 1.4 SS-Triphenyl phosphate Chrysene-d12 Methoxychlor 2.4 2.0 2.0 2.2 2.0 2.1 Bis(2-ethylhexyl)phthalate Benzo[a]pyrene 1.6 1.9 1.6 1.9 SS-Perylene-d12 2.1 2.0 1 pg OFN on SCION SQ Premier: EI; Full Scan (m/z: 50-300); Extracted ion: m/z 272; S/N specification: >1500:1 (RMS) S/N =13588 . 4 High-capacity Turbo Pump Ø Enables fast pump-down for higher productivity Ø CI ready (can handle high gas loads) Ø New high-capacity 300/400 **L/s design (Leybold-Turbovac series) • MinimumTimeBeforeFailure is 8yrs Scion Instruments GC-MS SQ approved for hydrogen carrier gas User Benefit: Higher Productivity Fast Pump-down and Dual Column Connection 1 1 . Fast Pump-down-Ready for use TIC Before Source Removal 1 2 TIC After 25 min Pump Down GCMS can be used in less than 30minutes after ON and pump down vacuum . 5 Ø Patented Post-filter design • Ø Ø Mass 18 OK Superior low mass sensitivity Unmatched negative-ion detection On-board processor for on the fly data averaging/filtering • Ø Detector Technology Reduces inter-scan (160kHz acquisition rate) supports 14,000 Da/s scan speed Mass 1200 OK Extended Dynamic Range Mass FIlter User Benefit: Ultra-high S/N & Negative Ion Sensitivity 1 3 . Scion Instruments Solution: EDR Detection System Saturated Detector 160ng Chrysene EDR On 160ng Chrysene Extended Dynamic Range mode continually ensures optimal detection in every scan for trace components as well as components that exist in great abundance within the same complex mixture. When detector approaches saturation, the system automatically lowers the multiplier voltage, always ensuring optimal detection of components, even if they co-elute. Easily analyze complex mixtures that contain both trace residues as well as compounds of high abundance in the same run. 1 5 . EDR Detection System EDR - 200 ng \ no detector saturation peak is on scale NO EDR- 200 ng \detector saturation! 1 6 NO SATURATION, Correct Mass Spectrum (for Qualitative analysis) Correct Peak Shape (for Quantitative analysis) . SCION SQ-Unique CBS Features Easily Convert Full Scan Methods to SIM Combine with Compound Based Scanning (CBS) for optimal method set-up Use Retention Time Update Tool for easy maintenance . Easily to Convert Full Scan to SIM! • Convert a full scan method to SIM • Create SIM method from a spectrum list and export to Excel . Save SIMs in User Library . CP-8400 and CP-8410 AutoSamplers Key Features • CP-8400. Sample capacity • CP-8410. Sample capacity • • • • • Two Injector Access Dual/Duplicate Injections Wide range of Syringes Sample Heating/Cooling Three Solvent Wash • Waste Drain • 32 100 x 2 mL 10 x 2 mL 6 x 5 mL 5 x 10 mL Upgradeable to Large Rinse Vial 32 . CP-84x0 Auto Sampler Two Injector Capability • Ability To Inject Into Two Ports: • • • • Requires Only One Tower Complete Control Through LUI Complete Control via Work Station Syringe away from heated injection port 436-GC two injections ports Only One CP-84x0 sampler required • • • • Top view Front & Middle Injector Middle & Rear Injector Syringe away from heated injection port . Versa Headspace Sampler • Can be use to analyze volatile compound in Solid, Film and Slurry sample • 20 possition autosampler • Sample heating up to 200oC 34 . Versa Headspace Sampler Static Headspace Vial Loop Loop 1) Sample (Slurry, Solid, Film) is placed in a sealed vial 2) Vial is typically heated 3) Volatiles leave the sample (matrix) and migrate into the gas phase (headspace) 4) Headspace is sampled and sent to the GC for analysis 35 . Column Detector .