U336 / UL263 2-HOUR FIRE RATED WALL ASSEMBLY FIRE SEPARATION WALL SHALL BE CONTINUOUS FROM SLAB TO ROOF SHEATHING & TIGHT AGAINST ALL EXTERIOR WALLS. PENETRATIONS SHALL COMPLY WITH NFPA 8.3.5. 2 HR RATED ASSEMBLY U336 CONT TO UNDERSIDE OF ROOF DECK 12" BLOW-IN INSUL OR MIN. PER CODE FIREBLOCKING AS REQ'D PRE ENG. TRUSSES BY MFR 12" BLOW-IN INSUL OR MIN. PER CODE FIREBLOCKING AS REQ'D 2x4 FRAMING @ 16" O.C. W/ KRAFT FACED R-13 BATT INSUL. 2x4 FRAMING @ 16" O.C. W/ KRAFT FACED R-13 BATT INSUL. 1/2" GYP BOARD 1/2" GYP BOARD TWO (2) 1" GYP LINER PANELS, FRICTION FIT 3/4" T&G DECKING (FINISH FLOOR TBD) 16" O.W.W. JOISTS @ 16" O.C. 6" FRICTION FIT SOUND BATT FIREBLOCKING AS REQ'D 3/4" T&G DECKING (FINISH FLOOR TBD) 16" O.W.W. JOISTS @ 16" O.C. 6" FRICTION FIT BATT INSUL. 0' - 11 1/2" FIREBLOCKING AS REQ'D 2 HR RATED ASSEMBLY U336 KRAFT FACED R-13 BATT INSUL. 2x4 FRAMING @ 16" O.C. W/ KRAFT FACED R-13 BATT INSUL. 2' - 0" 2x4 FRAMING @ 16" O.C. W/ KRAFT FACED R-13 BATT INSUL. 1' - 6" 2x4 FRAMING @ 16" O.C. 1/2" GYP BOARD 1/2" GYP BOARD 1' - 6" 2 HR RATED ASSEMBLY U336 IN-SLAB FTG 1/2" GYP BOARD TWO (2) 1" GYP LINER PANELS, FRICTION FIT SECTION 2 HOUR FIRE RATED ASSEMBLY U336/UL263 1 1/2" = 1'-0" PLAN