Building laws
1. Batas Pambansa Bilang 344 (Accessibility Law) and its Original
Amended Implementing
Rules and Regulations:
Item
APPENDIX A –
Minimum
Requirements for
Accessibility.
Requir
ed
Walkways should have a
maximum
cross gradient of 1:100.
Walkways should have a
minimum
of width of 1.20m.
Grating openings should
have
a
maximum
dimension of 13mm x
13mm and shall not project
more than 6.5 mm above
the level of the
walkway.
Walkways should have a
continuing surface without
abrupt pitches in angle or
interruptions by cracks or
breaks creating edges
above
6.50mm.
In
lengthy
or
busy
walkways, spaces should
be provided at some point
along the route so that a
wheelchair
may
pass
another or turn round.
These spaces should have
a minimum dimension of
1.50m and should be
spaced at a maximum
distance of 12.00m
between stops.
Walkway headroom should
not be
less than 2.0m and
preferably higher.
Signs attached on walls
should
have maximum height of
1.60m and minimum of
1.40m
For symbols, letters and
numbers
labelling rooms, raised
minimum of 1mm. Braille
can be use.
Central refuges serves
as mid
crossing shelter at least of
1.5m and preferably 2.0m
with carriage way width
exceeds 10.00m. (central
island)
Actual
1:100
1.50
13mm x 13mm
6.50mm
1.50m
3.00m
1.40m
1.00mm
2.00m
APPENDIX A –
Minimum
Requirements for
Accessibility.
Parking slots minimum
width of
3.70m
Accessible elevators should
be
provided one entrance level
Leveled vestibule for
entrances with
dimensions of 1.50m width
and 1.80m depth
Ramp clear width: 1.20m
Gradient of 1:12
1:12 gradient ramps should
not exceed 6.0m long.
Longer ramps with same
gradient
should
have
minimum landing of 1.50m
every
after 6.00m
Change of level not less
than
1.80m should provide
landings at the top and
bottom of any ramp
Handrails of 0.70m and
0.90m in
height should be provided
at both sides
Curbs on both sides of
ramp
minimum of 10mm support
for wheels (wheelchair)
For a rise of 0.20m and the
ramp directly towards a
road, provide railing across
the bottom of ramp its
full width not less than of
1.50m
Minimum clearance of door
is
0.80m
Clear
spaces
of
1.50mx1.50m
extending
and beyond door. A
minimum
distance
of
1.20m clearance from
edge of door panel
to the nearest wall should
maintain
and unobstructed. Provide
protections and stops for
door swing, walls, plants,
cabinet and other devices
that prevent from sudden
opening of doors; Minimum
width of corridor is 1.20m
3.70m
One entrance level
1.50m width and 1.80m
depth
1.20m
1:12
6.00m long ramps
with 1.50m landing
every 6.00 m
1.80m
0.70m and 0.90m
10mm
0.20m with 1.20 width
0.80m
1.
50m x 1.50m with 1.50
width of corridor
APPENDIX A –
Minimum
Requirements for
Accessibility.
Door hardware height
located between from
0.82m
and
1.06m
preferably 0.90m above the
floor;
Kick
plates
dimensions of 0.30m to
0.40m for major are doors
Threshold and sliding
doors tracks in ramped
form maximum height of
25mm
For switches manually
operated
1.20m – 1.30m above the
floor
Corridors with turnabout
space at
maximum distance of
12.00m for wheelchair turn
around
Minimum area of
1.70mx1.80m of
water closet stalls, provide
grab bars, one fixed and
one movable
Turning space of 2.25sq.m
with
minimum dimension of
1.50m
Maximum height of water
closet 0.45m flush control
of 1.20m
Maximum
height
of
lavatories
0.80m with knee recess
of 0.60m0.70m depth of 0.50m
Elongated lip of urinals
0.48m
Gray value color edge of
steps
Braille signs indicating
floor level located at
every door frame
0.90m with 0.30 kick
plates
25mm
1.30m
12.00m
1.70m x 1.80m
0.45m flush control with
1.20m height of
lavatories and 0.80 knee
recess
0.48m
Gray color
Braille signs at every door
frame
2. Presidential Decree (P.D) No. 1096 Adopting a National Building Code of
the Philippines
Item
Chapter VIII –
Light and
Ventilation
Required
Habitable rooms provided
with artificial ventilation
have ceiling heights not
less than 2.40 meters
measured from the floor to
the ceiling; Provided that
for buildings of more than
one-storey, the minimum
ceiling height of the first
storey shall be 2.70 meters
and that for the second
storey 2.40 meters and
succeeding storeys shall
have an unobstructed
typical
head-room
clearance of not less than
2.10 meters above the
finished floor. Above stated
rooms with a natural
ventilation
shall
have
ceiling height not less than
2.70
meters
Mezzanine floors shall have
a clear
ceiling height not less than
1.80 meters above and
below it.
Rooms for Human
Habitations.
6.00 square meters with at
least dimensions of 2.00
Kitchens. 3.00 square
meters with
at least dimension of 1.50
meters
Bath and toilet. 1.20 square
meters with at least
dimension of 0.90
meters.
Workshops, Factories, and
Offices.
12.00 cubic meters of
space per person
Habitable
rooms.
14.00 cubic
meters of space per
person.
Ventilation or vent shafts
shall have a horizontal
cross sectional area of not
less than 0.10 square
meter for every meter of
height of shaft but in no
case shall the area be less
than 1.00 square meter.
No vent shaft
Actual
3.00m
1.80m
6.00 sqm
Minimum of 3.00m
1.70m x 1.80m
12.00 cubic
meters/person
14.00 cubic
meter/person
shall
have
its
least
dimension less than 600
millimeters.
Chapter VIII –
Light and
Ventilation
Chapter X – Building
Projection over Public
Streets
Clearance. The horizontal
clearance between the
awning and the curb line
shall not be less than
300
millimeters.
The
vertical clearance between
the undermost surface of
the awning and the
pavement or ground line
shall be not less than 2.40
meters.
Collapsible
awnings shall be so
designated that they shall
not block a required exit
when collapsed or
folded.
Doors, windows and the
like less than 2.40 meters
above the pavement or
ground line shall not, when
fully opened or upon
opening, project beyond
the property line
except fire exit doors.
The horizontal clearance
between the outermost
edge of the marquee and
the carb line shall be not
less than 300 millimeters.
The vertical clearance
between the pavement or
ground line and the under
surface of any part of the
marquee
shall not be less than 3.00
meters.
Number of Exits. Every
building or
usable portion thereof shall
have at least one exit. In
all occupancies, floors
above the first storey
having an occupant load of
more than 10 shall not have
less than two exits. Each
mezzanine floor used for
other than storage
purposes, if greater in area
than 185 square meters or
more than 18.00 meters in
any dimension, shall have
at least than two stairways
to an
adjacent floor.
300
mm
and
2.40 meters
3.00 m
300 mm
Rise and Run. The rise of
every step in a stairway
shall
not
exceed
200
200mm x 250 mm
millimeters and the run
shall not less than 250
millimeters. The maximum
variations in the height of
risers and the width of
treads in any one flight
shall
be
5
millimeters:
Except, in case of private
stairways
serving
an
occupant load of less than
10, the rise may be 200
millimeters and the run
may be 250
millimeter.
Width. Every aisle shall be
not
less
than
800
1.20 – to 3.00 meters
aisle
millimeters wide if serving
only one side, and not less
than 1 meter wide if serving
both sides. Such minimum
width shall be measured at
the point farthest from an
exit, crosssle, or foyer and
shall be increased by 30
millimeters
for
every
meters in length towards
the
exit, crosssle or foyer
In Groups C, H and E
Occupancies, aisles shall
Ailes were not to be
not be provided a dead end
provided a dead end not
greater than
6.00 meters in length.
Width. The width if any seat
be not
less than 450 millimeters.
greater than 6.00 in
length.
Seat: 450mm x 450mm
3. Fire Code of the Philippines (RA9514)
Item
Division V – Means of
Egress
Required
Actual
The width of any means of
egress shall not be less
than nine hundred fifteen
1.60m of egress,
millimeters
(915
mm)
double door
except when specifically
provided under Division 8
to Division 17 of this
Chapter.
The travel distance to an
exit shall be measured on
the floor or other walking
surface along the center
line of the natural path of
travel, starting from the
most remote point subject
to occupancy, curving
around any corner or
0.30m clearance
construction with a thirty
(30) centimeter clearance
therefrom, and ending at
the center of the doorway
or other point at which the
exit
begins.
Where
measurement
includes
stairs, it shall be taken in
the place
of the tread nosing.
In the case of open areas,
distance to exits shall be
measured from the most
remote point subject to
occupancy. In case of
individual rooms subject to 30m distance of exit for
occupancy by not more
more than 6
than six (6) persons,
persons
distance to exits shall be
measured from the floors of
such rooms provided the
path of travel from any
point in the room to the
room door does not
exceed fifteen meters (15
m).
The minimum headroom
shall not
be less than two meters (2
Min. headroom: 3.00
m) nor any projection from
meters
the ceiling be less than two
meters (2 m) from the
floor.
Door openings in means of
egress shall not be less
than seventy one
centimeters (71 cm) in clear
width. When a pair of doors Door openings: 800mm
is provided, not less than
one of the doors shall
provide at least seventy
one centimeters (71 cm)
clear width
opening.
Handrails on stairs shall be
not less than seventy six
centimeters (76 cm) nor
more than eighty six and
one-half centimeters (86.5
cm) above the upper
surface of the tread,
measured vertically to the
top of the rail from a point
0.90 vertically measured
on the tread twenty five
handrails
millimeters (25 mm) back
from the leading edge,
except on stairways
designed 68 for use by
children an additional
handrail may be provided
lower
than the main handrail.
Handrails shall provide a
clearance of at least thirty
eight (38) millimeters
between handrail and wall
to which it is fastened.
0.40 clearance between
Handrails shall be of such
handrail and wall.
design and so supported as
to withstand a load of not
less than ninety one kilos
(91 kg) applied to any point,
downward or horizontally.
Vestibules shall have a
dimension of not less than
one hundred twelve
centimeters (112 cm) in
width and
not less than one
Vestibule is at minimum of
hundred eighty three
1.50 meters
centimeters (183 cm) in
direction of travel.
three centimeters (183 cm)
in
direction of travel.
To serve as a smoke and
heat trap and to provide an
upward moving air column,
the vestibule ceiling shall
be not less than five
hundred ten millimeters
(510 mm) higher than the
door opening into the
Vestibule is at minimum of
vestibule. The height shall
1.50 meters
be permitted to be
decreased where justified
by engineering design and
field testing.
Maximum slope 1 in 12
1:12 slope ratio
Minimum widths 60 cm
clear
between rails
Minimum horizontal
dimension any
landing of platform 60 cm
1.20 width between rails
1.50 horizontal dimension of
landing platform
Maximum rise 23 cm
Rise is at 0.20m
Headroom, minimum 2.00
m
Min. headroom is 2.25
Risers Maximum height
between
landings 3.66 m
0.20m risers
Minimum tread, exclusive
of nosing
23 cm
0.25m tread
Iron, steel, or reinforced or
concrete or other approved
noncombustible material
shall be used for the
construction of fire stairs,
balconies, railings, and
Steel will be used for railings
other
features appurtenant
thereto.
All fire escape shall have
walls or guards on both
sides, in accordance with
para “H” of Section
10.2.5.4 of this IRR, except
for height, which shall be
one hundred seven
centimeters (107
cm) and ninety one
0.90 meters guards on both
centimeters (91
sides
4. BP 344 The Law to Enhance Mobility of Disabled Person
Disabled Persons




Confinement to wheelchair
Difficulty in walking
Total impairment due to aging
Mental impairment
Size of wheelchair




Length 1.10 to 1.30
Width 0.60 to 0.75
Turning space 1.50
Clear space under table 0.75
Parking slots





Width 3.70 with 1.20
50 to 100 slots
Elevators 30.00
Distance from entrance 1.10 x 1.40
Button heights 0.90 to 1.20
Walkways




Width 1.20 min.
Gradient 1:20 or 5% max.
Cross gradient 1:100 width or 1.50 x 1.90
Lengthy walkways rest top, max. distance 12.00 between stops
Washrooms & storage











Stall 1.70 x 1.80
Turning space 1.50
No. of water closets for disable 1.20+ if greater than 20
Height of water closet 0.45
Flush 1.20
Max. height of lavatories 0.80
Knee recess height 0.60 – 0.70
Depth 0.50
Handrail 0.80
Urinal height 0.48
Turnabouts 1.50 x 1.50
5. R.A. 9275 Philippine Clean Air Act of 2004
Section 7. To establish sewerage, seepage, and sewerage – seepage facilities in
their respective localities or jurisdiction. Within five (5) years following the effectivity of the
Act, subdivision, condominiums, commercial centers, hotels, sports and recreational
facilities, hospitals, market places, public buildings, industrial complexes, including
households are required to connect to available sewerage system.