The fastest chiller restart after power failure QUICK START FEATURE Ensure the fastest chiller restarts with Quick Start feature Temperature-sensitive operations such as data center, pharmaceutical, and manufacturing facilities require constant cooling for equipment and processes. If power fails and cooling is interrupted, critical operations may also fail — risking millions of dollars in equipment failure and operational downtime. Now there‘s a sure way to reduce the risk of cooling disruption — the Quick Start feature from Johnson Controls. This feature for YORK® centrifugal chillers with OptiSpeed™ variable-speed drive can save you both time and money by: • Reducing time for chiller restart after power failure • Rapidly re-establishing chilled-water temperature • Keeping process equipment cooled • Reducing risks of expensive downtime • Providing a faster initial start, too Reduce restart time to seconds After power is interrupted, it can take a standard centrifugal chiller many minutes to restart. But with the Quick Start feature, once power is restored, the chiller can restart in as little as 25 seconds! However, we understand that your application does not just require the chiller to restart, but needs the fastest delivery of chilled water at the design temperature. In Figures 1, 2, and 3 on the next page, restart times are measured from the moment the power fails, and the backup generator is assumed to have established emergency power in 15 seconds. Quick Start feature without UPS is fast: • Once emergency power is established, the chiller can restart as soon as the OptiView™ control panel reboots (75 seconds) and the OptiSpeed drive precharges (25 seconds), assuming coastdown of the compressor has been completed. If emergency power is available after 15 seconds, the chiller will restart in 115 seconds after power was lost. Quick Start feature with UPS is faster: 15 25 Power VSD failure precharge 60 Coastdown* 15 Power failure 60 seconds to restart with UPS 340 320 300 280 260 240 220 200 180 160 140 120 100 80 60 40 249 seconds = about 4 minutes Standard Chiller Quick Start without UPS Quick Start with UPS 115 seconds = almost 2 minutes 60 seconds 0 5 10 15 sec. 20 power failure 25 30 35 Length of power failure (seconds) Figure 2: Restart times for 500-ton chiller. Proven performance With over 100 Quick Start installations in the field, you get the peace of mind knowing your chillers — and your operation — can be protected from the consequences of power failure by Johnson Controls. For details on how the Quick Start feature can protect your application, contact your nearby Johnson Controls sales office today. 60 Coastdown* OptiView Chiller control panel reboot 75 60 VSD 115 seconds precharge to restart Additional steps required if UPS not used *Coastdown time for a 500-ton chiller Figure 1: Required steps when power interruption occurs with and without UPS. Faster restart restores specified leaving chilled-water temperature quicker The Quick Start feature not only minimizes chiller restart time, it reduces the time required for the re-establishment of the design leaving chilled-water temperature (LCHWT). The Quick Start feature utilizes accelerated loading logic, with the inlet vanes fully open, to re-establish the specified leaving chilledwater temperature faster. While the actual time to re-establish the LCHWT will depend on plant design, compressor size, and operating conditions, a chiller equipped with the Quick Start option can cut the time by as much as 70%. Printed on recycled paper. PUBL-6113 (909) © 2009 Johnson Controls, Inc. P.O. Box 423, Milwaukee, WI 53201 Printed in USA www.johnsoncontrols.com LCHWT: Standard Logic Setpoint Quick Start with UPS 58 25 Temperature (degrees F) With UPS Without UPS Timeline from loss of power • The UPS keeps the OptiView and OptiSpeed control circuits energized and the oil heater operative until the emergency generator is activated, which eliminates the need for control panel reboot. The chiller will restart in 60 seconds after power was lost. Time to restart from power loss (seconds) Faster restarts due to smarter power management The Quick Start feature is available in two configurations, for use with or without an uninterruptible power supply (UPS): 56 54 52 50 48 10 minutes 12 seconds 3 minutes 2 seconds 46 44 42 40 –2 0 2 4 6 8 Time from power failure (minutes) Figure 3: Time to re-establish LCHWT for 500-ton chiller at low load. 10 12